This document contains a request for proposal for a Launch Operations Support Contract. The 30th Space Wing at Vandenberg Air Force Base, California is soliciting proposals to provide launch operations support services. Interested contractors should review the 15 attachments outlining requirements such as the performance work statement, government furnished property, security classification specifications, and Department of Labor wage determinations. Proposals are due no later than January 27, 2022, and the North American Industry Classification System code for this effort is 561210 for Facilities Support Services. The small business size standard is $41.5 million. Questions regarding the final RFP are due by January 4, 2022 and should be submitted to the primary and secondary points of contact via email.
View the file
Other files
Show 40 more
Latest 50 of 137 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Axiomatic Technologies Corporation 5915 Wallace Street, Mississauga, Ontario Canada L4Z 1Z8
TEL: (905) 602-9270 x225 FAX: (905) 602-9279 E-mail: sales@axiomatic.com www.axiomatic.com
TECHNICAL DATASHEET #TD2302AX
Isolated Current Converter
P/N: IIC-DR-22
Description: The Isolated Current Converter accepts a 24VDC power supply (nominal). A 0-200 mA input signal is converted to a 4-20 mA current output. Span and zero are user adjustable. Diagnostic LEDs indicate power and operational status. The output LED is on when the load, input signal and power supply are connected. The LED flashes when the load is disconnected. The load can be floating or grounded. The unit is available in a DIN rail mount housing.
Application: As part of a load management strategy for a marine propulsion system, the unit converts a 0-200 mA load signal from a diesel engine control computer to a 4-20 mA signal for a variable pitch propeller control system.
Technical Specifications:
Typical at nominal input voltage and 25 degrees C unless otherwise specified
Ordering Part Number: IIC-DR-22 Input Specifications:
Current Input 0-200 mA Isolation Isolated from output and power supply.
Output Specifications:
Current Output 4-20 mA Isolation Isolated from input and power supply.
Response Time 10 mSec.
Non-linearity <0.1% without adjustments performed General Specifications:
Power Supply 24VDC nominal (9-45VDC operating range)
Transient protection is provided.
Power Consumption 48 mA @ 12VDC
20.2 mA @ 24VDC Reverse Polarity Protection Provided Power LED Indicator ON = Power OK Output LED Indicator ON when load, input signal and power supply are connected.
FLASHING when load is disconnected.
Operating Conditions -40 to 85 degrees C (-40 to 185 degrees F) Electrical Connection Screw terminals accept 14-24 AWG wire Weight 0.25 lbs. (0.113 kg) Protection PCB conformal coated
IP40 rated housing, Terminals rated at IP20 Packaging and Dimensions (W x H x D)
DR12, Polycarbonate (75 x 98.5 x 22.5 mm or 2.95 x 3.88 x 0.89 inches) DIN rail mount for high profile DIN rail (35 mm)
TD2302AX 2
Adjustments: Multi-turn trim pots (10 turns) Zero CW = increasing
Apply 0 mA input current and adjust the Zero trimpot to 4 mA output current.
Span CW = increasing Apply 200 mA input current and adjust the Span trimpot to 20 mA current output.
CW = clockwise
Specifications are indicative and subject to change. Actual performance will vary depending on the application and operating conditions. Users should satisfy themselves that the product is suitable for use in the intended application. All our products carry a limited warranty against defects in material and workmanship. Please refer to our Warranty, Application Approvals/Limitations and Return Materials Process as described on www.axiomatic.com/service.html.