TE-QQ_Water_Tret_Stands_Boilers_Revision 1.docx

DOCX document 23 KB Posted

Attached to
Base Operations Support Services, Dugway Proving Ground, Utah Federal contract opportunity
Solicitation number
W5168W23R0002
Issued by
Department of the Army

View the file

Other files for this federal contract opportunity

Other files attached to Base Operations Support Services, Dugway Proving Ground, Utah, newest first.
File Type Posted
Attachment S - PIEE Solicitation Vendor Posting Offer Training.pdf PDF
Attachment H - Dugway Pricing Matrix Revised 14 JUN 23 Cell J31 Formula.xlsx XLSX spreadsheet
Amended_RFP_W5168W23R0002_0005_DPG_BASOPS_12JUN2023_w_Changes.pdf PDF
Amended RFP W5168W23R0002-0003-Conformed Document -.pdf PDF
DGP BaseOps Site visit Sign-in Roster 2-2-2023.pdf PDF
Attachment 5 - Past Performance Questionnaire.docx DOCX document
Attachment 6 - Pricing Matrix.xlsx XLSX spreadsheet
Attachment 18 - CLS 411 Facility Maintenance_ Vertical_12 Apr 22.docx DOCX document
Attachment 22 - CLS 502 Water Services_12 Apr 22.docx DOCX document
Attachment 24 - CLS 510 Pest Management_12 Apr 22.docx DOCX document
Attachment 15 - CLS 404 Grounds Maintenance_12 Apr 22.docx DOCX document
TE-VVVV Master keys dupicate keys and locks.docx DOCX document
TE-L_Irrigation_Systems_Drawing_1-35 Revision 1.pdf PDF
TE-YY_Evaporative_Coolers_Revision 1.pdf PDF
TE-EE__Unpaved_Roads_Revision 1.pdf PDF
TE-U-1_Ditto_Improved_Area_Revision 1.pdf PDF
TE-V-2_MAAF_Avery_Semi-Improved_Land_Area_Revision 1.pdf PDF
TE-V-1_Ditto_Semi-Improved_Land_Area_Revision 1.pdf PDF
TE-DDDD OSHA 3138-01R 2004. Confined Spaces.pdf PDF
TE-FF_Snow_Removal_Priorities_Revision 1.pdf PDF
TE-G_Burn_Rate_Example_Revision 1.xlsx XLSX spreadsheet
TE-ZZZ_Self_Help_Stock_Level_Revision 1.pdf PDF
TE-A_Automation_Technology_Revision 1.pdf PDF
TE-SSSS Stored Presticides Report Example.xlsx XLSX spreadsheet
TE-DDD Deliverable Schedule-DUGWW6B6AAWKI13.docx DOCX document
TE-PP Boilers 20200506.xlsx XLSX spreadsheet
TE-KKK_Government_Owned_Propane__Tanks_Revision 1.xlsx XLSX spreadsheet
TE-JJJ_Fire_Pump_Data_Revision 1.xlsx XLSX spreadsheet
TE-HHH_Clean_Agent_Fire_Suppression_System_Revision 1.xlsx XLSX spreadsheet
TE-CC-1_Out_of_cycle_request_Revision 1.xlsx XLSX spreadsheet
TE-BBB-1_AST-UllageLog_Revision 1.docx DOCX document
TE-ZZZZ Priority Facilities.xlsx XLSX spreadsheet
TE-XXXX Tank List.xlsx XLSX spreadsheet
TE-WWW_List_Army_Housing_Units_Revision 2.xlsx XLSX spreadsheet
TE-C_ISR_Requirements_Revision 1.pdf PDF
TE-NNNN Monthly Pest Management Operations Record.xlsx XLSX spreadsheet
TE-AA_Pure_Live_Seed_Mix_Revision 1.pdf PDF
Attachment 12 - Collective Bargaining Agreement (CBA).pdf PDF
Attachment 10 - DBA Wage Determination - Highway.pdf PDF
Attachment 9 - DBA Wage Determination - Heavy.pdf PDF
Attachment 14 - CLS 201 AFH Management Operation_12 Apr 22.docx DOCX document
TE-YYY_Number_Movements_and_Placements_Revision 1.xlsx XLSX spreadsheet
TE-V-3_Baker_Semi-Improved_Land_Area_Revision 1.pdf PDF
TE-UU_Exhaust_Fans_Revision 1.pdf PDF
TE-RRR_WasteWater_Treatment_Systems_Revision1.pdf PDF
TE-V-4_Carr_Semi-Improved_Land_Area_Revision 1.pdf PDF
TE-V_English_Village_Semi-Improved_Land_Area_Revision 1.pdf PDF
TE-VV_Air_Compressors_Revision 1.pdf PDF
TE-T_Hantavirus_Contamination_Prevention_Revision 1.pdf PDF
TE-XX_HVAC_Filters_Revision 1.pdf PDF
Show all 50

Base Operations Support Services, Dugway Proving Ground, Utah has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Technical Exhibit

TE-QQ

Revision 1

Water Treatment Standards US Army Boiler Water Treatment Standards per USACEISC 2003 Facilities Engineering Corrosion Control

Steam Boilers below 300 psi

Test Acceptable Ranges

Sodium Hydroxide20200 ppm as OH
or 100-600 ppm as CaCO3
Sodium Phosphate3060 ppm
Sodium Sulfite20-40 ppm
Total dissolved solids3 000-3,500 ppm water tube boilers
3,500-5000 ppm fire tube boilers
TanninMedium or Dark
Polymer (dispersant)5-10 ppm
Silica< 200 ppm
pH10.5-12.0

Condensate Water Test Acceptable Ranges

pH7.5 8.8
Conductivity< 35 micromhos
Hardness as (Ca Co)<2 ppm

Softened Water

Hardness < 2 ppm

HTHW Generators > 350 degree F

Non-Cascade Type

Test Acceptable Ranges

pH9.3 9.9
Sodium Sulfite20-40 ppm
Hardness as (Ca Co)<2 ppm
Water Softener effluentshall be recharged if it exceeds 2 ppm