TE-HHH_Clean_Agent_Fire_Suppression_System_Revision 1.xlsx

XLSX spreadsheet 22 KB Posted

Attached to
Base Operations Support Services, Dugway Proving Ground, Utah Federal contract opportunity
Solicitation number
W5168W23R0002
Issued by
Department of the Army

View the file

Other files for this federal contract opportunity

Other files attached to Base Operations Support Services, Dugway Proving Ground, Utah, newest first.
File Type Posted
W5168W23R0002-0005 DOCUMENTS.zip ZIP file
Amended_RFP_W5168W23R0002_0004_DPG_BASOPS_31MAY2023.pdf PDF
Amended RFP W5168W23R0002-0003.pdf PDF
AMENDMENT 0003 DPG BASOPS TECHNICAL EXHIBITS.zip ZIP file
Amended_RFP_W5168W23R0002_0002_DPG_BASOPS_27APR2023.pdf PDF
Attachment 7 - Staffing Matrix.xlsx XLSX spreadsheet
Attachment 3 - Installation Fueling Services_12 Apr 22.docx DOCX document
Attachment 13 - CLS 200 UPH Management Operation_12 Apr 22.docx DOCX document
Attachment 17 - CLS 408 Pavement Clearance_12 Apr 22.docx DOCX document
Attachment 16 - CLS 406 Attachment 2 Real Property.docx DOCX document
TE-GGGG Water Line Flush Record Deliverable Example and Flush Point Drawing.pdf PDF
TE-MMMM Dugway Area Map Place of Performance.pdf PDF
TE-AAAA ArMA Process.pdf PDF
TE-R_Historic_Buildings_Revision 1.pdf PDF
TE-JJ_Generator_List_Revision 1.pdf PDF
TE-TTTT Pesticide Use Record Example.xlsx XLSX spreadsheet
TE-SS_Air_Conditioner_Systems_revision1.xlsx XLSX spreadsheet
TE-EEE_Unaccompanied_Housing_Facilities_Revision 1.xlsx XLSX spreadsheet
TE-TTT_Well_Water_Report_Sample_Revision 1.docx DOCX document
TE-QQQQ List of Lift Stations and Location.xlsx XLSX spreadsheet
TE-PPPP BUILDER Facilities.xlsx XLSX spreadsheet
TE-QQ_Water_Tret_Stands_Boilers_Revision 1.docx DOCX document
TE-LLL_Utility_Data_Revision 1.docx DOCX document
TE-LL_UPS_Locations_Revision 1.xlsx XLSX spreadsheet
TE-FFFF EDS distribution.docx DOCX document
TE-E_Outstanding_Obligations_Report_Revision 1.xlsx XLSX spreadsheet
TE-EEEE Lighting Guidelines.docx DOCX document
TE-AAA_AST_and_UST_Revision 1.xlsx XLSX spreadsheet
TE-BB-1_Daily_Report_Revision 1.docx DOCX document
TE-BBB_AST-Visual_Inspect_Form-revision1.docx DOCX document
TE-YYYY Monthly Delivery Report.xlsx XLSX spreadsheet
Attachment 12 - Collective Bargaining Agreement (CBA).pdf PDF
Attachment 10 - DBA Wage Determination - Highway.pdf PDF
Attachment 9 - DBA Wage Determination - Heavy.pdf PDF
Attachment 14 - CLS 201 AFH Management Operation_12 Apr 22.docx DOCX document
TE-YYY_Number_Movements_and_Placements_Revision 1.xlsx XLSX spreadsheet
TE-V-3_Baker_Semi-Improved_Land_Area_Revision 1.pdf PDF
TE-UU_Exhaust_Fans_Revision 1.pdf PDF
TE-RRR_WasteWater_Treatment_Systems_Revision1.pdf PDF
TE-V-4_Carr_Semi-Improved_Land_Area_Revision 1.pdf PDF
TE-V_English_Village_Semi-Improved_Land_Area_Revision 1.pdf PDF
TE-VV_Air_Compressors_Revision 1.pdf PDF
TE-T_Hantavirus_Contamination_Prevention_Revision 1.pdf PDF
TE-XX_HVAC_Filters_Revision 1.pdf PDF
TE-N_Water_Contamination_Threat_Revision 1.pdf PDF
TE-SSS_Water Operating Logs_Sample_Revision 1.pdf PDF
TE-ZZ_Food_Service__Equipment_Revision 1.pdf PDF
TE-M_High_Priority_Facilities_Revision 1.pdf PDF
TE-B_Typical_Certifications_Revision 1.pdf PDF
TE-K_Government_Facilities_for_Use_by_Contract_Revision 1.pdf PDF
Show all 50

Base Operations Support Services, Dugway Proving Ground, Utah has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Clean Agent Fire Supression Systems TE-HHH
MISSION & INSTALLATION CONTRACTING COMMAND
Dugway Proving Ground Contracting Office
Technical Exhibit HHH
CONTRACTOR:
CONTRACT:
Building #Comm. NodesInstall DateAss. No.SN#Gross Wt.Tare Wt.Clean Agent Wt. or Cubic FeetTank Mfg. Date/ Agent Type
54445212CPY-250-24-3-0155321166155 LB2014 / FM200
54445212CPY-150-24-3-09521411995 LB2014 / FM200
54445212CPY-375-24-3-0250501251250 LB2014 / FM200
54445212CPY-375-24-3-0300558258300 LB2014 / FM200
5326 S. BLDG521270-153-D-W0809660-318375108 LB2008 / FM200
5326 MIDDLE521270-153-D-W0809660-218375108 LB2008 / FM200
5326 N. BLDG521270-153-D-W0809660-118476108 LB2008 / FM200
533052121015145522.5222.5300 LB2009 / FM200
4531 ZONE14132CPY-375-12-1-0305555240305 LB2009 / FM200
4531 ZONE24132CPY-150-12-1-0101215.8114.8101 LB2013 / FM200
4531 ZONE24132CPY-560-12-1-440684244440 LB2013 / FM200
4531 ZONE24132CPY-150-12-1-080019511580 LB2013 / FM200
4531 ZONE24132CPY-375-12-1-255505250255 LB2013 / FM200
4531 ZONE24132CPY-375-12-1-195447252195 LB2013 / FM200
4531 ZONE24132CPY-150-12-1-89205.5116.589 LB2013 / FM200
4531 ZONE34132CPY-560-12-1-0380715335380 LB2009 / FM200
4531 ZONE34132CPY-70-12-1-0051108.3557.3551 LB2009 / FM200
4531 ZONE34132CPY-150-12-1-0130243.4109.4134 LB2009 / FM200
4531 ZONE34132CPY-375-12-1-0235486251235 LB2009 / FM200
4531 ZONE54132CPY-375-24-1-0365612247365 LB2009 / FM200
9425 KITCHEN2045IS35ABC35 LB2012 / DRY CHEMICAL
9425 LAB204570-154-D-W946076284160124 LB2009 / FE25
9423204570-153-D-W946075152.877.875 LB2009 / FE25
7146204534 MAIN TANKS3400 LB2006 / CARBON DIOXIDE
7146204534 SPARE TANKS3400 LB2006 / CARBON DIOXIDE
73532045570009476.2243.2233 LB2010 / FM200
73532045570346961.7505.7456 LB2010 / FM200
73532045570008444.4208.4236 LB2010 / FM200
1010 ELEC ROOM101070-268-D-W1207912341.5146.5195 LB2011 / FM200
1010 HAMSTER ROOM101070-267-D-W1207913228.5118.5110 LB2011 / FM200
1010 UPSTAIRS101070-257-D-W1207910224119105 LB2012 / FM200
4258413228069435 cu.ft1998 / Inergen
425841321751435 cu.ft1998 / Inergen
4258413228029435 cu.ft1998 / Inergen
4258413227907435 cu.ft1998 / Inergen
4258413227951435 cu. Ft.1998 / Inergen
4258413228375435 cu. ft1998 / Inergen
4258413228210435 cu. Ft1998 / Inergen
STHILPCMS3/3/0870-152-D-W0729170-296" 8 oz51" 8 oz45"7/6/07Example