| Location: | JAMES L. KING FED. JUSTICE BLD | Property Manager: | Paul A. Smith | |
| Bldg. # | FL1021ZZ | 99 N.E. 4th St | ||
| Miami, FL 33132 |
Contract Specialist Carolina McFaul O & M Contractor IEI
General Information:
Quantity of Floors 12 Age of Building 24 Operating Hours 24/7
| Elevators | Building Operating Plan | Yes | Quantity of Agencies | 4 | ||
| Judges | 1 | |||||
| Passengers | 5 | List Agencies *(Of special note are law enforcement and agencies with 24 hour operations)* | ||||
| Freight | 1 | US Attorney's (USAO), Court of Appeals (CoA), Distrcit Courts, US Marshals | ||||
| Prisoner | 2 | |||||
| Total | 9 |
Comments:
Child Care Centers
| Interior: | ||
| Special Equipment | No | If yes, identify below: |
| Playground | No | ||||
| Environmental | |||||
| GSA Owned Fuel Tanks | Qty. | Asbestos | No | ||
| Above Ground | 1 | ||||
| Under Ground | Lead Paint | No |
GSA Owned Generators 1 PCB's No
Firing Range No If yes, last date of lead clean up?
Note to Contractor: Asbestos, Lead, or any other hazardous material may be in the building (particularly older ones) and has not been discovered yet so all suspicious material found should be treated as such.
Major Alteration Project:
Comments:
| Building Equipment |
| Building Automation System |
Make Tridium Model Niagara Software Version 7.1
Is BAS on GSA network? Yes Types of controller? Pneumatics and DDC
HVAC
| Item | Qty | Item | Qty | Item | Qty | Item | Qty |
| AHU | 12 | PIU | FCU | 4 | RTU | ||
| VAV | 240 | OAF | VAV w Fan | 147 | RAF | ||
| Duct Heaters |
Chillers
Qty. 2
| Make | Trane | Model | CVHE 500 | Serial # | L14B00825 |
| Evaporator Eddy Current Date | Tonnage | 385 | Condenser Eddy Current Date |
| Make | Trane | Model | CVHE 500 | Serial # | L14B00838 |
| Evaporator Eddy Current Date | Tonnage | 385 | Condenser Eddy Current Date |
| Make | Model | Serial # |
| Evaporator Eddy Current Date | Tonnage | Condenser Eddy Current Date |
| Make | Model | Serial # |
| Evaporator Eddy Current Date | Tonnage | Condenser Eddy Current Date |
UPS Systems
Qty. Ownership GSA
Make Model Serial #
Make Model Serial #
Make Model Serial #
Domestic Water Heater
Qty. 11 Last Inspection Date 1/2020
Make LOCHINVAR Model LSK040KK Serial # KA0989847 Type Electric
Make LOCHINVAR Model LSK040KK Serial # KA0989881 Type Electric
Make RELIANCE Model 640DOLNS Serial # A07A131071 Type Electric
Make HOTPOINT Model HE30S1A Serial # 0104B11992 Type Electric
Make GE Model GE10P6A Serial # GE0399313247 Type Electric
Make LOCHINVAR Model LSK040KK Serial # TM 0834408 Type Electric
Make AMERICAN Model Serial # 9818113846 Type Electric
Make LOCHINVAR Model LSK040KK Serial # TM 17885020 Type Electric
Make LOVHINVAR Model LSK040KK Serial # TM 0835898 Type Electric
Make LOCHINVAR Model JRC020E-1 Serial # JJ0513346 Type Electric
Make RHEEM Model RHESPR030-2 Serial # RH0999F02552 Type Electric
| Make | Model | Serial # | Type |
| Make | Model | Serial # | Type |
Make Model Serial # Type
Make Model Serial # Type
Make Model Serial # Type
Make Model Serial # Type
Make Model Serial # Type
Make Model Serial # Type
Make Model Serial # Type
Make Model Serial # Type
Make Model Serial # Type
Make Model Serial # Type
Make Model Serial # Type
Qty. Last Inspection Date
Type Make Model Serial#
Type Make Model Serial#
Type Make Model Serial#
Type Make Model Serial#
Cooling Towers
Qty. 2
Make MARLEY Model NC 8306H-2SS Serial # N/A
Make MARLEY Model NC 8306H-255 Serial # N/A
Make Model Serial #
Generators
Building Load 0.6KVA Last Load Bank Test Last Fuel Analysis 3/20
| Make | CATERPILLAR | Model | 3508 | Serial # | 6NA02958 | Gas | Diesel | |
| Fuel Capacity | 2000 |
Make Model Serial # Gas Natural Gas
Fuel Capacity
Make Model Serial # Gas Natural Gas
Fuel Capacity
Fire Alarm System
Make Honeywell Model E4 Serial #
Device Count
| Smoke Detector | 124 | Phoneline for Central Station Montoring | O&M Contractor | |
| Heat Detector | 11 | |||
| Duct Detector | 24 | Date of last annual test? | 9/2019 | |
| Pull Station | 25 | |||
| Water Flows | 12 | |||
| Tampers | 14 | |||
| Strobes | 30 | |||
| Speakers | 0 | |||
| Combo. Speaker / Strobes | 57 | |||
| Beam Detectors | 0 | |||
| Batteries | 6 |
Fire Sprinkler System
| Wet | Yes | Date of last annual test? | 9/19 | Date of last semi-annual test? |
| Dry | Date of last annual test? | Date of last semi-annual test? | ||
| Stand Pipe | Yes | Date of last annual test? | 9/19 | Date of last semi-annual test? |
Does building have a fire pump? Yes
Specialize Fire Suppression Systems
| FM-200 | Date of last annual test? |
| CO2 | Date of last annual test? |
| Inergen | Date of last annual test? |
| Novec1230 | Date of last annual test? |
| IG55 | Date of last annual test? |
Does building have a kitchen hood system? No
Emergency Lights
How many battery operated emergency lights at facility? 170
Fire Extinguishers Types
| Type | QTY. | |
| Water | How many require 12 year hydrostatic testing? | |
| A-B-C | 96 | |
| B-C | ||
| CO2 | ||
| K |
Security System
Card Readers
Make Model Qty.
Key Pads
Make Model Qty.
Parking Security Devices
| Items | Qty. | Items | Qty. | Items | Qty. |
| Pop Up Bollard | Wedge Plates | 1 | Judges Garage Doors | ||
| Building Garage Doors | 3 | Sally Ports | 1 | Building Gates | 1 |
Plumbing
| Back Flow Prevention Devices | Last Testing Date | 9/2019 | ||
| Qty. | 4 |
| Item | Qty. | Item | Qty. |
| Automatic Soap Dispensers | Outside Water Hoses Bibbs | 1 | |
| Automatic Towel Dispensers | FDC Connections | 4 | |
| Automatic Flush Valves | Emergency Eye Wash Stations/ Showers | 2 | |
| Automatic Faucets | Hot Water Circulation Pump | N/A | |
| Water Fountains with Filters | 7 | Roof Drains | 10 |
| Water Filters | Outside Drains | 6 | |
| Building Ice Makers | |||
| Grease Traps |
Decorative Water Fountains No
| Waterless Urinal | No | ||
| Make | Model | Qty. | |
| Make | Model | Qty. |
Roof System
What is the age of roof? 12
Warranty 20 yrs Warranty Holder John Manville
Does roof have anchorage point system installed?
If Yes, how many and what type?
| Item | Qty. |
| Anchor Point | |
| Davit Arms |
Electrical System
| Last thermal scan completion date? | 3/2019 | |
| Has Arch Flash Study been completed? | No | If yes, what is the completion date? |
| Last date of switchgear testing? | 3/2018 | ||
| Specialize Chemical Free Water Treatment System | No |
If yes, what type of system is installed?
| Warranty | Yes | Warranty Expiration Date |
| Warranty Holder Information |