The file's text, extracted by GovTribe without its formatting.
Amendment 0003
This Amendment is to answer the following questions from industry:
Q.1. Does the Gov’t have required Delivery dates for the Base and Option periods?
A.1. No, Offerors are to provide their best possible delivery timeframe for the base and option periods.
Q.2. In Section L, 1.3 (a) of Vol III, Past Performance is limited to 1 page. In Section 3.2, offerors may provide up to three past performance references. Is this page count 1 for each reference?
A.2. Yes, this is a page count of one (1) for each reference.
Q.3. Will the government allow a Title Page, Table of Contents, and Acronym List, in each proposal volume, that are not included in the maximum pages count?
A.3. Yes, a Title Page, Table of Contents, and Acronym List will be allowed in each proposal volume. They are NOT included in the maximum page count.
Q.4. Section L, paragraph 4.0 states that the Offeror shall provide proposed unit prices for CLINs 0001-006 by filling in the Section B Pricing Tables. However, there is no Section B included with the corresponding RFQ attachments. Could the Government please either provide a Section B Pricing Table for Offeror’s to fill in as part of their Cost proposal, or provide clarification on where Offeror’s are to include unit pricing for all CLINs?
A.4. Please see the table below. Offerors to fill out the proposed cost column.
| 0001 |
| Spares – This option allows for the procurement of one set of spare parts. Some of the |
| 1 |
parts for the LCDP can be difficult to obtain and the spare parts will mitigate the risk of schedule delays due to missing or damaged part orders as the spare parts can be used until the replacement parts arrive. Once the contract is completed the parts will be delivered to the government to support the Three-Inch Launcher Test Facility (TILTF) and the fleet.
| 0002 |
| Base order of five (5) LCDPs |
| 0003 |
| · Option 1 – This option is for the procurement of up to three (3) additional LCDPs |
| 0004 |
| · Option 2 – This option is for the procurement of up to three (3) additional LCDPs |
| 0005 |
| · Option 3 – This option is for the procurement of up to three (3) additional LCDPs |
| 0006 |
| · Option 4 – This option is for the procurement of up to three (3) additional LCDPs |
Q.5. In Section 4.4 of the SOW, the Spares List table has duplicate rows for the same ICL LCDP Circuit Card Assembly (Part Number 8816871). It is listed in both the first and last rows of the table. Could the Government please clarify if the last row was included in error and that Part Number 8816871 should only be listed once?
A.5. Part Number 8816871, Internal Countermeasure Launcher Launch Control and Display Panel Circuit Card Assemble, Quantity 3 listed at the bottom of the spare kit table in Section 4.4 is a repeat and will be removed.
Please see the spares kit table below which incorporates the revision mentioned in A.5.:
| Part Number |
| Description |
| Qty |
| 8816871 |
| ICL LCDP Circuit Card Assy |
| 3 |
| 8816909 |
| ICL LCDP 28 VDC Power Supply |
| 1 |
| 8328575-1 |
| Switch/Indicator Light Assy |
| 2 |
| 8328575-2 |
| Switch/Indicator Light Assy |
| 2 |
| 8328575-3 |
| Switch/Indicator Light Assy |
| 2 |
| 8328575-13 |
| Switch/Indicator Light Assy |
| 1 |
| 8328575-12 |
| Switch/Indicator Light Assy |
| 2 |
| 8328575-14 |
| Switch/Indicator Light Assy |
| 3 |
| 8328575-15 |
| Switch/Indicator Light Assy |
| 2 |
| 8328575-16 |
| Switch/Indicator Light Assy |
| 2 |
| 8816868-16 |
| Gasket, Left Front Panel |
| 1 |
| 8816868-17 |
| Gasket, Right Front Panel |
| 1 |
| 8328575-9 |
| Switch/Indicator Light Assy |
| 2 |
| 8328575-10 |
| Switch/Indicator Light Assy |
| 1 |
| 8328575-11 |
| Switch/Indicator Light Assy |
| 1 |
| F03A250V3AS |
| Fuse, CRTG, Norm BLOW |
| 6 |
| F03A250V1AS |
| Fuse, CRTG, Norm BLOW |
| 5 |
| M7793-10A |
| Meter, Time, TOTLZ, Digital |
| 1 |
| MS16106-5 |
| Switch Assy, Interlock, Unsealed |
| 2 |
| M22885/80-50 |
| Terminal, CRIMP, CONN Block (800-CT20-3) |
| 125 |
| MS27721-23-1D |
| Switch Toggle, Miniature, Double pole toggle |
seal, Lever Lock
| MS24660-23D |
| Switch Toggle, Four Pole, Environmentally |
Sealed, Lever Lock
| MS27720-23-1D |
| Switch Toggle, Miniature, Single pole toggle |
seal, lever lock
| MS27720-26-1F |
| Switch Toggle, Miniature, Single pole toggle |
seal, lever lock
| 20VR1 |
| CORCOM Power Line Filter |
| 1 |