MIL-STD-2003-3A.pdf

PDF 2 MB Posted

Attached to
USS SAMPSON 8C1 DSRA Federal contract opportunity
Solicitation number
N4523A-18-R-0550
Issued by
Department of the Navy Naval Sea Systems Command

View the file

Other files for this federal contract opportunity

Other files attached to USS SAMPSON 8C1 DSRA, newest first.
File Type Posted
N4523A-18-R-0550_Amendment_0018.pdf PDF
DDG-102_SA_288K_HAZMINCEN_POAM.PDF PDF
551-8749120_Rev_A,_HYBRID_ELEC_DRIVE_PIPING_-AIR_SYS_MODS_&_ML.pdf PDF
J-1_Work_Package_ERRATA_6.pdf PDF
BQ_026_Missing_Refs-Answered_Redacted.pdf PDF
BQ_025_Missing_Refs-Answered_Redacted.pdf PDF
BQ_21_123-21-001_-_Redacted.pdf PDF
BQ_020_077-10-001_-_Answered_1-16-18_Redacted.pdf PDF
J-14_Pricing_Workbook_111517_rev001_(ECN).xlsx XLSX spreadsheet
BQ_010_077-10-001_vs_solicitation_-_Answered_1-11-18_Redacted.pdf PDF
BQ_013_53711-5808784M.PDF PDF
J-1_Work_Package_Errata_5_-_Addendum_1.pdf PDF
BQ_006_437-012-001_Possible_Source_-_Answered_1-5-18_Redacted.pdf PDF
N4523A-18-R-0550_J-12_Pre-Proposal_Information_(PPI)_Form_Q_009_-_Answered_09JAN18_Redacted.pdf PDF
BQ_004_Bearing_Staves_-_Answered_1-5-18_Redacted.pdf PDF
N4523A-18-R-0550_J-12_Pre-Proposal_Information_(PPI)_Form_Q_003_Redacted.pdf PDF
N4523A-18-R-0550_J-12_Pre-Proposal_Information_(PPI)_Form_Q_001_Redacted.pdf PDF
N4523A-18-R-0550_J-12_Pre-Proposal_Information_(PPI)_Form_Q_014_Redacted.pdf PDF
N4523A-18-R-0550_J-12_Pre-Proposal_Information_(PPI)_Form_Q_005_Redacted.pdf PDF
N4523A-18-R-0550_J-12_Pre-Proposal_Information_(PPI)_Form_Q_015_Map_3.pdf PDF
BQ_001_Extension_Request.pdf PDF
J-11_8010_Manual_19April2016_REV_00_ACN_1A.PDF PDF
J-16_CDRL_A006_Request_for_Technical_Deviation.pdf PDF
J-16_CDRL_A031_Demand_Only_Transactions.pdf PDF
J-17_Integrated_Schedule_&_Testing_-_Rev_1.docx DOCX document
MIL_STD_777F.pdf PDF
J-16_CDRL_B002_Logistics_Mgmt_-_EDFP.pdf PDF
MIL-STD-2191.pdf PDF
J-16_CDRL_A018_Critically_Coated_Surfaces_Rprt.pdf PDF
N4523A-18-R-0550_Solicitation.pdf PDF
J-16_CDRL_A013_Process_Control_Procedure.pdf PDF
J-16_CDRL_A019_Incident_Report.pdf PDF
J-16_CDRL_A010_Tank_Report.pdf PDF
J-12_Pre-Proposal_Information_(PPI)_Form.doc DOC document
J-16_CDRL_A035_Progress,_Status_and_Mgmt_Rprt.pdf PDF
J-16_CDRL_A030_Weight_and_Stability_Rprt.pdf PDF
J-16_CDRL_A026_Comp_Closeout_Insp_Rprt.pdf PDF
J-3_Key_Events_and_Milestone_Listing.pdf PDF
MIL-STD-3026.pdf PDF
J-20_Open_and_Inspect_Reports.xlsx XLSX spreadsheet
29_CFR_1915_Occupational_Safety_and_Health_Admin.,_Labor.pdf PDF
J-16_CDRL_A037_Contractor's_Training_Plan.pdf PDF
J-16_CDRL_A005_Purchase_Order.pdf PDF
NFPA_70,_National_Electrical_Code.pdf PDF
J-16_CDRL_A034_Technical_Report_-_Configuration.pdf PDF
J-16_CDRL_A009_Work_Completion_Certification.pdf PDF
J-8_Contractor_Proposal_Guide.pdf PDF
J-16_DIDs_Package.pdf PDF
59312-3-005_Rev_A,_VCHT_Tank_Level_Indicator_Sensor_Test.pdf PDF
J-9_Env_Guide_For_Contractors_at_NSE_-_May16.pdf PDF
Show all 50

USS SAMPSON 8C1 DSRA has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMSC N/A AREA SESS

INCH-POUND

MIL-STD-2003-3A(SH)

3 September 2009

SUPERSEDING

DOD-STD-2003-3(SH)

24 June 1987

DEPARTMENT OF DEFENSE

STANDARD PRACTICE

ELECTRIC PLANT INSTALLATION

STANDARD METHODS FOR

SURFACE SHIPS AND SUBMARINES

(PENETRATIONS)

Source: http://www.assistdocs.com -- Downloaded: 2010-11-30T15:44Z Check the source to verify that this is the current version before use.

MIL-STD-2003-3A(SH)

ii

FOREWORD

1. This standard is approved for use by the Naval Sea Systems Command, Department of the Navy, and is available for use by all Departments and Agencies of the Department of Defense.

2. This standard disseminates up-to-date information detailing requirements for standard installation methods employed for submarine and surface ship electrical distribution systems.

3. These criteria apply to work on a specific ship or ships only when invoked by the Ship Specifications or similar contractual documents.

4. These criteria are for application to new construction, conversion, and alteration of existing ships.

5. Considering the magnitude of this standard, along with the changing requirements imposed on the Electric Plant, it is inevitable that changes will be required to update these criteria. Therefore, as comments arise, they should be forwarded to Naval Sea Systems Command (NAVSEA) 05Z3 to keep this standard as current as possible through subsequent revisions. Revisions will be accomplished by the issuance of additional or revised figures to be inserted in the basic standard parts. Superseded pages may be retained for reference if so desired.

6. Comments, suggestions, or questions on this document should be addressed to Commander, Naval Sea Systems Command, ATTN: SEA 05M2, 1333 Isaac Hull Avenue, SE, Stop 5160, Washington Navy Yard DC 20376- 5160 or emailed to CommandStandards@navy.mil, with the subject line “Document Comment”. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at http://assist.daps.dla.mil.

mailto:CommandStandards@navy.mil� http://assist.daps.dla.mil/� iii

CONTENTS

PARAGRAPH PAGE

1. SCOPE

1.1 Scope

1.1.1 Application

2. APPLICABLE DOCUMENTS

2.1 General

2.2 Government documents

2.2.1 Specifications, standards, and handbooks

2.2.2 Other Government documents, drawings, and publications

2.3 Non-Government publications

2.4 Order of precedence

3. DEFINITIONS

3.1 Collective protective system (CPS)

3.2 Community stuffing tube for bulkheads

3.3 Kickpipe

3.4 Metal stuffing tube

3.4.1 Nylon stuffing tube

3.5 Multiple cable penetrator (MCP)

3.6 Swage tube

4. GENERAL REQUIREMENTS

4.1 Cable penetrations

4.1.1 Installation welding requirements

4.1.2 Cable penetration of structure

4.1.3 Cable penetration of decks and bulkheads forming boundaries of spaces containing volatile combustible or explosive materials

4.1.4 Cable penetration of decks, structural bulkheads, airtight bulkheads, and fume-tight bulkheads

4.1.5 Multiple (two or more) penetrations of nonstructural steel bulkheads (other than wire mesh or expanded metal), bends, web frames, transverse girders, and longitudinal girders

4.1.6 Plastic sealer

4.1.7 Cable penetrations spacing

4.1.8 Stuffing tube packing

4.1.9 Kickpipes

5. DETAILED REQUIREMENTS

6. NOTES

6.1 Intended use

6.2 Acquisition requirements

6.3 Designation of electric plant installation standard methods figures

6.4 Subject term (key word) listing

6.5 Changes from previous issue

APPENDIX A Penetrations – Stuffing Tubes, Submarines APPENDIX B Penetrations – Stuffing Tubes, Surface Ships APPENDIX C Penetrations – Stuffing Tubes, General APPENDIX D Penetrations – Kickpipes APPENDIX E Penetrations – Pressure Hulls, Submarines

1. SCOPE

1.1 Scope. This standard covers standard methods for swage tubes, stuffing tubes, and kickpipes on surface ships and submarines.

1.1.1 Application. These installation methods are to be used by all installing activities. These methods do not identify ship or type, but do establish minimum standards of acceptance for Naval ships. It is the responsibility of the user activity to determine which method satisfies their requirements. It does not authorize relaxation of any requirement specifically invoked by new construction, conversion, overhaul, or refurbishment contracts. In instances where deviated design requirements (for example, ship type, ship class, and so forth) conflict with the requirements of this standard, the requirements of this standard govern. Any deviation for electric plant installation identified in this standard is to be submitted to NAVSEA 05Z3 for resolution.

2. APPLICABLE DOCUMENTS

2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this standard. This section does not include documents cited in other sections of this standard or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this standard, whether or not they are listed.

2.2 Government documents.

2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.

COMMERCIAL ITEM DESCRIPTIONS

A-A-3041 - Wrench, Open End Ratchet (TAC Pattern) for Tube Fitting, Electrical Cable Terminals, and Stuffing Tube Gland Nuts

A-A-3042 - Socket, Open Detachable, Standard Wall, Octagon

DEPARTMENT OF DEFENSE SPECIFICATIONS

MIL-I-3064 - Insulation, Electrical, Plastic-Sealer

MIL-PRF-15624 - Gasket Material, Rubber, 50 Durometer Hardness (Maximum)

MIL-DTL-16685 - Packing, Material and Packing Preformed (Stuffing Tube for Electric Cable)

MIL-S-24235 - Stuffing Tubes, Metal, and Packing Assemblies for Electric Cables, General Specification for

MIL-S-24235/1 - Stuffing Tubes, Metal, and Packing Assemblies for Electric Cables, Bulkhead, Pressureproof

MIL-P-24705 - Penetrators, Multiple Cable, for Electric Cables, General Specification for

(Copies of these documents are available online at http://assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)

Source: http://www.assistdocs.com -- Downloaded: 2010-11-30T15:44Z http://assist.daps.dla.mil/quicksearch/�

2.2.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.

NAVAL SEA SYSTEMS COMMAND (NAVSEA) DESIGN DATA SHEETS

DDS 100-1 - Reinforcement of Openings in Structure of Surface Ships Other Than in Protective Planting

DDS 100-2 - Openings in Decks and Bulkheads for Stuffing Tubes and Pipe

(Copies of these documents are available from Commander, Naval Sea Systems Command, ATTN: SEA 05M2, 1333 Isaac Hull Avenue, SE, Stop 5160, Washington Navy Yard DC 20376-5160, or by email at CommandStandards@navy.mil with the subject line “DDS request”.)

NAVAL SEA SYSTEMS COMMAND (NAVSEA) PUBLICATIONS

S9074-AR-GIB-010/278 - Requirements for Fabrication Welding and Inspection, and Casting Inspection and Repair for Machinery, Piping, and Pressure Vessels

(Copies of this document are available from the Naval Logistics Library, 5450 Carlisle Pike, Mechanicsburg, PA 17055 or online at http://nll.ahf.nmci.navy.mil.)

2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.

ASTM INTERNATIONAL

ASTM F1836M - Standard Specification for Stuffing Tubes, Nylon, and Packing Assemblies (Metric)

(Copies of this document are available from ASTM International, 100 Barr Harbor Dr., P.O. Box C700, West Conshohocken, PA 19428-2959 or online at www.astm.org.)

2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained.

3. DEFINITIONS

3.1 Collective protective system (CPS). CPS is a system designed to inhibit the entry of chemical, biological, and radiological contaminants into collective protection zones on board ships. A collective protection zone is a section of the ship, which is defined by a physical boundary that inhibits the entry of CBR contaminants into the zone. A total protection zone is pressurized to 2 inches WG and its supply ventilation air is continuously filtered to remove chemical vapors and CBR particulate and aerosols.

3.2 Community stuffing tube for bulkheads. Community stuffing tube for bulkheads is a system of passing multiple cables through ballast tank bulkheads on submarines.

3.3 Kickpipe. Kickpipe is a pipe welded into the deck with a stuffing tube attached. Kickpipes provide protection of electrical cable at deck penetrations and are used to clear an obstruction or preserve alignment.

Kickpipes may be aluminum, steel, stainless steel, or brass to suit the installation or standard pipe sizes to suit the required stuffing tube.

3.4 Metal stuffing tube. Metal stuffing tube is a system of passing single electrical cable through decks and bulkheads and entering enclosed equipment on Naval ships. Metal stuffing tubes are manufactured in accordance with MIL-S-24235. Stainless steel is an alternative material which should be considered for use in applications highly susceptible to corrosion.

Source: http://www.assistdocs.com -- Downloaded: 2010-11-30T15:44Z Check the source to verify that this is the current version before use.

mailto:CommandStandards@navy.mil� http://nll.ahf.nmci.navy.mil/� http://www.astm.org/�

3.4.1 Nylon stuffing tube. Nylon stuffing tube is a system of passing single electrical cable through electrical equipment on Naval ships. Nylon stuffing tubes are manufactured in accordance with ASTM F1836M.

3.5 Multiple cable penetrator (MCP). MCP is a system of passing multiple cables through watertight and non-watertight bulkheads and decks in order to provide watertight, airtight, and firetight penetration of electrical cable.

3.6 Swage tube. Swage tube is a system of passing single cables through decks on Naval ships that combines the features of the stuffing tube and kickpipe.

4. GENERAL REQUIREMENTS

4.1 Cable penetrations. Cable penetrations of pressure hulls, pressure-proof bulkheads, shielded bulkheads, ballistic bulkheads, false decks, riser boxes, decks, bulkheads and beams and other integral parts of the hull shall be in accordance with figures 3A1 through 3E7 and the requirements of DDS 100-1 and DDS 100-2.

4.1.1 Installation welding requirements. Unless otherwise specified on the individual figure, the welding of stuffing tubes, kickpipes, swage tubes, and multi-cable penetrators shall be in accordance with the requirements of

NAVSEA S9074-AR-GIB-010/278.

4.1.2 Cable penetration of structure. Cable penetration of decks, bulkheads, beams, and other integral parts of the hull shall conform to DDS 100-1 and DDS 100-2. Stuffing tubes in accordance with MIL-S-24235/1 shall be installed for cable penetrations of pressure-proof submarine bulkheads and sonar domes, which are filled with water under normal operating conditions. Stuffing tubes in accordance with MIL-S-24235/1 may be cut in half and each half used for a separate penetration.

Metal stuffing tubes or multiple cable penetrators shall be used for cable penetrations of the following (Note:

Multiple cable penetrators shall not be used for cable penetrations exposed to weather or in tanks.):

a. CPS boundaries

b. Watertight cable trunks

c. Watertight bulkheads

d. Bulkheads designed to withstand a waterhead

e. The portion of bulkheads specified to be watertight to a certain height

f. That portion of bulkheads below the height of the sill or the coaming of compartment accesses

g. Bulkheads surrounding compartments subject to flooding by sprinkling (if watertight):

1. Garbage disposal rooms

2. Battery shops

3. Medical operating rooms

4. Medical wards

4.1.3 Cable penetration of decks and bulkheads forming boundaries of spaces containing volatile combustible or explosive materials. Metal stuffing tubes and back-to-back multi-cable penetrations in accordance with MIL-P- 24705 shall be installed in decks and bulkheads forming the boundaries of spaces containing volatile combustible or explosive materials.

4.1.4 Cable penetration of decks, structural bulkheads, airtight bulkheads, and fume-tight bulkheads. Unless otherwise specified, cable penetration of decks, structural bulkheads, airtight bulkheads, and fume-tight bulkheads shall employ one of the following:

Note: All surface ship stuffing tubes installed shall show a minimum of two threads and a maximum of five threads on the gland nut after it is tightened.

a. Airtight metal stuffing tubes or multiple cable penetrators.

b. Fume-tight chaffing collars (for multiple cable penetrations) or nipples (for single cable penetrations) having a minimum collar length of three inches with a minimum annular area between the cable and the collar of one inch with the entire void area within the collar (this includes the area between the collar and the cable and the area between the cables) packed with plastic sealer.

4.1.5 Multiple (two or more) penetrations of nonstructural steel bulkheads (other than wire mesh or expanded metal), bends, web frames, transverse girders, and longitudinal girders. Unless otherwise specified, multiple cable penetrations of nonstructural steel bulkheads, bents, web frames, transverse girders, and longitudinal girders shall employ one of the following:

a. Metal stuffing tubes, multiple cable penetrators, nipples (for single cable penetrations) having a minimum length of two inches with a minimum annular area between the cable and the nipple of ¼ inch packed with plastic sealer

b. Banding collars (for multiple cable penetrations) having a minimum collar length of three inches with a minimum annular area between the cable and the collar of one inch with the entire void area within the collar (this includes the area between the collar and the cable and the area between the cables) packed with plastic sealer.

Cable penetrations of vertical non-tight structures within a compartment need not be sealed. However, all chaffing collars of the structures selected for sealing shall be sealed.

4.1.6 Plastic sealer. After the cables are properly secured, plastic sealer electrical insulation (MIL-I-3064, Type HF) shall be used to seal the space around the cable as follows:

a. In cable clamps and bushings entering the top of an electrical enclosure and the side of an enclosure without a drip loop.

b. In bushings or nipples used for passing cables through light-tight and fume-tight bulkheads and to seal around cables as they enter stuffing tubes, kickpipes, and swage tubes as shown on the individual figures except that plastic sealer is not required when silicone (red or white) grommets are used. Where compartment air tests are required, it is recommended that plastic sealer be installed after the air test has been satisfactorily performed.

4.1.7 Cable penetrations spacing. The size of stuffing tube groups shall be limited to permit tightening of gland nuts in the group using stuffing tube wrench set, A-A-3041 and A-A-3042. Penetration is specified in DDS 100-2.

4.1.8 Stuffing tube packing. Stuffing tube packing shall be in accordance with MIL-DTL-16685, either the preformed (coil) Class 2 or bulk Class 1. When bulk packing is used, the first and last turns shall be part “A” (hard) and the intermediate turns shall be part “B” (soft) of Class 1. Reinforced neoprene packing, in accordance with MIL-G-15624, CL I, may be used as an alternate, asbestos-free, packing material (see figure 3B48).

4.1.9 Kickpipes. Kickpipes – aluminum, brass, stainless steel, or steel – shall be standard pipe sizes. Ends of pipe shall be chamfered and burrs existing on the inside wall shall be removed to prevent chafing of cable.

5. DETAILED REQUIREMENTS

(See figures.)

6. NOTES

(This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.)

6.1 Intended use. This section specifies the requirements for swage tubes, stuffing tubes, and kickpipe methods to be employed both on surface ships and submarines. Standard methods identified for electric plant installation are intended for new construction, conversion, and alteration of existing ships.

6.2 Acquisition requirements. Acquisition documents should specify the following:

a. Title, number, and date of this standard.

6.3 Designation of electric plant installation standard methods figures. The electric plant installation standard method MIL-STD-2003-3 contains drawings that depict standard methods that are applicable for general electric plant installation on both surface ships and submarines. Each drawing has been assigned a figure number. The methods shown on the figures are grouped together providing similar functions. These groups are:

MIL-STD-2003-3 (Penetrations) Group A. Stuffing tubes, Submarines

B. Stuffing tubes, Surface Ships

C. Stuffing tubes, General

D. Kickpipes

E. Pressure Hulls, Submarines

The methods shown on the figures are identified by the following alphanumeric designation system:

METHOD 3A-14-2 3 A- 14- 2

Method (always the last number)

Sequential figure number

Group number

Military Standard section 3

Thus, Method 3A-14-2 identifies Method 2, sequential number 14 in Group A of MIL-STD-2003-3.

6.4 Subject term (key word) listing.

Kickpipes Multi-cable transits Stuffing tubes

6.5 Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes.

APPENDIX A

GROUP 3A – PENETRATIONS – STUFFING TUBES, SUBMARINES

A.1 SCOPE

A.1.1 Scope. This appendix describes the installation standard methods for stuffing tubes in submarines.

A.2. APPLICABLE DOCUMENTS

A.2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this standard. This section does not include documents cited in other sections of this standard or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this standard, whether or not they are listed.

A.2.2 Government documents.

A.2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.

FEDERAL SPECIFICATIONS

MMM-A-121 - Adhesive, Bonding Vulcanized Synthetic Rubber to Steel

COMMERCIAL ITEM DESCRIPTIONS

A-A-3041 - Wrench, Open End Ratchet (TAC Pattern) for Tube Fitting, Electrical Cable Terminals, and Stuffing Tube Gland Nuts

A-A-3042 - Socket, Open Detachable, Standard Wall, Octagon

A-A-59588 - Rubber, Silicone

DEPARTMENT OF DEFENSE SPECIFICATIONS

MIL-DTL-915 - Cable, Electrical, for Shipboard Use, General Specification for

MIL-I-3064 - Insulation, Electrical, Plastic-Sealer

MIL-PRF-8516 - Sealing Compound, Synthetic Rubber, Electric Connectors and Electric Systems, Chemically Cured

MIL-DTL-16685 - Packing, Material and Packing Preformed (Stuffing Tube for Electric Cable)

MIL-S-22698 - Steel Plate, Shapes and Bars, Weldable Ordinary Strength and Higher Strength: Structural

MIL-C-24231 - Connectors, Plugs, Receptacles, Adapters, Hull Inserts, and Hull Insert Plugs, Pressure-Proof, General Specification for

MIL-S-24235 - Stuffing Tubes, Metal, and Packing Assemblies for Electric Cables, General Specification for

MIL-S-24235/1 - Stuffing Tubes, Metal, and Packing Assemblies for Electric Cables, Bulkhead, Pressureproof

MIL-S-24235/2 - Stuffing Tube, Packing Assemblies for Pressureproof Bulkhead

MIL-S-24235/5 - Stuffing Tubes, Metal, and Packing Assemblies for Electric Cables, Ballast Tank

MIL-S-24235/7 - Stuffing Tubes, Metal, and Packing Assemblies for Electric Cables, for Cast Enclosures, Pressureproof

MIL-S-24235/8 - Stuffing Tubes, Metal, and Packing Assemblies for Electric Cables, for Sheet Metal Enclosures, Pressureproof

MIL-S-24235/14 - Stuffing Tubes, Metal, and Packing Assemblies for Electric Cables, for Sheet Metal Enclosures

MIL-P-24338 - Pipe, Carbon Steel, Seamless

MIL-DTL-24640 - Cables, Light-Weight, Electric, for Shipboard Use, General Specification for

MIL-DTL-24643 - Cables and Cords, Electric, Low Smoke, for Shipboard Use, General Specification for

DEPARTMENT OF DEFENSE STANDARDS

MIL-STD-1689 - Fabrication, Welding, and Inspection of Ships Structure

MIL-STD-2003 - Electric Plant Installation Standard Methods for Surface Ships and Submarines

(Copies of these documents are available online at http://assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)

A.2.2.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.

NAVAL SEA SYSTEMS COMMAND (NAVSEA) DRAWINGS

9000-S6202-51-L -

9000-S6202-5100L -

9000-S6202-73241 - Cable Clamp, Type C A&D

9000-S6202-73899 -

9000-S6202-1197101 - Tube, Stuffing, PP for SS & TSP Type Cables

SS-302-1716060 -

SS-302-1885724 - Extended Body Stuffing Tube, Assembly & Details

(Copies of these documents are available from Commander, Portsmouth Naval Shipyard, ATTN: Code 280.1, Kittery, ME 03904.)

NAVAL SEA SYSTEMS COMMAND (NAVSEA) PUBLICATIONS

T9074-AD-GIB-010/1688 - Fabrication, Welding and Inspection of Submarine Structure;

Requirements

(Copies of this document are available from the Naval Logistics Library, 5450 Carlisle Pike, Mechanicsburg, PA 17055 or online at http://nll.ahf.nmci.navy.mil.)

Source: http://www.assistdocs.com -- Downloaded: 2010-11-30T15:44Z Check the source to verify that this is the current version before use.

http://assist.daps.dla.mil/quicksearch/� http://nll.ahf.nmci.navy.mil/�

A.2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.

ASME INTERNATIONAL

ASME Y14.38 - Abbreviations and Acronyms for Use on Drawings and Related Documents

(Copies of this document are available from ASME International, 22 Law Drive, P.O. Box 2900, Fairfield, NJ 07007-2900 or online at www.asme.org.)

ASTM INTERNATIONAL

ASTM A53/A53M - Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless

ASTM B21/B21M - Standard Specification for Naval Brass Rod, Bar, and Shapes

ASTM B150/150M - Standard Specification for Aluminum Bronze Rod, Bar, and Shapes

ASTM B169/169M - Standard Specification for Aluminum Bronze Sheet, Strip, and Rolled Bar

(Copies of these documents are available from ASTM International, 100 Barr Harbor Dr., P.O. Box C700, West Conshohocken, PA 19428-2959 or online at www.astm.org.)

SAE INTERNATIONAL

SAE-AMS-P-83461 - Packing, Preformed, Petroleum Hydraulic Fluid Resistant, Improved Performance at 275Mdf (135Mdc)

SAE-AMS-S-8802 - Sealing Compound, Temperature Resistant, Integral Fuel Tanks and Fuel Cell Cavities, High Adhesion

(Copies of these documents are available from SAE World Headquarters, 400 Commonwealth Drive, Warrendale, PA 15096-0001 or online at www.sae.org.)

A.2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained.

A.3 REQUIRED EQUIPMENT AND MATERIALS

A.3.1 Required equipment and materials. The required equipment and materials for the proper installation of submarine stuffing tubes are as shown in the Appendix A methods.

A.4 NOTES AND PROCEDURES

A.4.1 Dimensions. For figures and tables in this section, all dimensions are in inches unless otherwise noted.

A.4.2 Figures. Table 3AI provides information for the figures in this group.

http://www.asme.org/� http://www.astm.org/� http://www.sae.org/�

TABLE 3AI. Figures for submarine stuffing tubes installation.

Figure number Submarine stuffing tubes installation Page

3A1 Passing cables through pressure-proof bulkheads – submarine instructions for packing stuffing tubes manufactured in accordance with drawing 9000-S6202-73899 (figures 3A11 and 3A12)

3A2 Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors

3A3 Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors

3A4 Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors

3A5 Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors

3A6 Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors

3A7 Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors

3A8 Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors

3A9 Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors

3A10 MIL-S-24235/1 stuffing tubes for passing cables through pressureproof bulkheads (submarines)

3A11 Stuffing tubes for passing cable through pressure-proof bulkheads type 1 & 2 of drawing 9000-S6202-73899 (submarines)

3A12 Stuffing tubes for passing cable through pressure-proof bulkheads type 3 & 4 of drawing 9000-S6202-73899 (submarines)

3A13 MIL-S-24235/5 stuffing tube for passing cable through ballast tank partitions (submarines)

3A14 Passing cable through tanks (pipe extension) (submarines) 27 3A15 MIL-S-24235 stuffing tube for passing cables through shielded bulkheads (submarines) 28 3A16 Cables through elliptical bulkheads (submarines) 29 3A17 Method of changing sizes of installed bulkhead stuffing tubes types 1 to 4 of drawing

9000-S6202-73899 & 46-1 of drawing 9000-S6202-5100L (submarines)

3A18 Sealing plugs for blanking steel stuffing tubes (submarines) 32 3A19 Temporary plugging of steel stuffing tubes (submarines) 34 3A20 Bushing sleeves for drawing 9000-S6202-73899 stuffing tubes through steel shielded bulkheads

3A21 Size and details of adapters used for changing size of installed bulkhead stuffing tubes – 9000-S6202-73899 (submarines)

3A22 Size and details of adapter used for changing size of installed steel bulkhead MIL-S- 24235 stuffing tubes (submarines)

3A23 Bushing sleeves for MIL-S-24235 stuffing tubes through steel shielded bulkheads 42

TABLE 3AI. Figures for submarine stuffing tubes installation - Continued.

Figure number Submarine stuffing tubes installation Page

3A24 Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors

3A25 Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors

3A26 Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors

3A27 Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors

3A28 Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors

3A29 Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors

3A30 Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors

3A31 Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors

Instructions for packing existing stuffing tubes – submarines (see note 1)

NOTES:

1. Stuffing tubes designed for cables in accordance with MIL-DTL-915, MIL-DTL-24640, and

MIL-DTL-24643.

2. Tubes may be thrown out of line by welding; this is allowed up to 1⁄16".

3. Sealing compounds and activators are to be equal to any of the types listed in table 3A1-I. The individual activator with its compound shall be mixed in accordance with the manufacturer’s instructions. See note 6.

TABLE 3A1-I. Sealing compounds.

Brand name Curing agent or catalyst Manufacturer’s name

XK-263 AL-15B Activator Acme Wire Company MMM-EC 1239 or equal

(SAE-AMS-S-8802 CL B-4)

Minnesota Mining and

Manufacturing Co.

PR-1201-Q MIL-PRF-8516, Type II, Class III PR-1201-QA Products Research Company

4. After the cables are properly secured, plastic sealer (electrical insulation MIL-I-3064, Type HF) shall be used to seal the space around the cable within the gland nut, and also within the open end of stuffing tubes, after the tubes are packed.

5. Stuffing tubes with insufficient clearance for passing cables may be reamed in place, not exceeding 0.031".

6. Many thermosetting plastic ingredients have poor shelf life. It is recommended that activator and hardener over three months in storage be discarded and replaced.

7. Instructions contained herein are intended for use with presently installed tubes where it is necessary to:

a. Replace existing cables

b. Install undersized cables

Instructions:

1. Type 1 (see figure 3A11):

a. Both ends of tube may be packed with prefabricated packing in accordance with MIL-DTL-16685.

b. Both gland nuts shall be tightened to give the prefabricated packing an initial set. Then the gland nuts should be removed and a split gland ring (Method 3A-11-3) added to each end of the tube.

c. Both gland nuts shall be tightened. For cables with a minimum outside diameter, where the gland nut cannot be sufficiently tightened, additional split gland rings (Method 3A-11-3) may be added to each end of the tube. The gland nuts in the final tightened position shall have the undercut and 2 or 3 threads exposed.

2. Type 2 (see figure 3A11):

a. The tubes should be installed in the bulkhead with the air relief screw on the top and the 90-degree ⅛"

I.P.S. fitting on the bottom.

b. Same as 1(a) above.

c. Same as 1(b) above.

d. Same as 1(c) above.

e. With the air relief screw backed off and using a lever operated lubricating gun with a flexible hose, fill the center position of the stuffing tube with sealing compound. See table 3A1-I for material. When sealing compound exudes from the air relief screw, secure the screw and continue the sealing of the stuffing tube with an additional eight to fifteen strokes of the lubricating gun. The additional strokes are to make certain that the center portion of the tube is completely filled with the compound. Free or excessive leakage of the sealing compound around the gland nuts indicates that the tube has been improperly packed. Where this occurs, the tube end must be repacked.

FIGURE 3A1. Passing cables through pressure-proof bulkheads – submarine instructions for packing stuffing tubes manufactured in accordance with drawing 9000-S6202-73899 (figures 3A11 and 3A12).

Instructions (continued):

3. Type 3 (see figure 3A12):

a. Same as 1(a) above.

b. Same as 1(b) above.

c. Same as 1(c) above.

4. Type 4 (see figure 3A12):

a. Same as 2(a) above.

b. Both ends of the tube shall be packed with a single ring, butt ended tight of flexible metallic packing

(Navy symbol 1430) forced tightly into place, followed by one ring of sealing packing (MIL-DTL-16685, Composition B) and one tapered ring of retainer packing (MIL-DTL-16685, Composition A). These packing rings shall be set up tight using the spacer sleeve, which provides the cavity for the sealing compound. The purpose of the packing up to this point is to seal off the space around the cable within the pipe extension to prevent entry of the sealing compound.

c. Same as 1(a) above.

d. Same as 1(b) above.

e. Same as 1(c) above.

f. Same as 2(e) above.

5. General instructions (all types):

a. With gland nuts, rings and packing sets in place, care must be taken to properly guide the cable through the tube to prevent damage or injury to the packing sets.

b. On cables where the initial clearance between the packing set and the armor is not sufficient to allow the cable to be pulled through the stuffing tube with the packing set and gland nut in place, the packing sets may be stretched and the gland nut, ring, and packing allowed to ride free on the cable until the cable is pulled into position. The packing set may be stretched by the use of a smooth tapered rod.

c. Where welding room is available, installation shall be the same as Types 1 and 2. If backing plate is necessary, it shall be the diameter of the tube plus 1", thickness 3⁄16".

d. Welding shall be in accordance with NAVSEA T9074-AD-GIB-010/1688.

FIGURE 3A1. Passing cables through pressure-proof bulkheads – submarine instructions for packing stuffing tubes manufactured in accordance with drawing 9000-S6202-73899 (figures 3A11 and 3A12) - Continued.

Cable Nylon tube MCP Stuffing tube Cable Size OD Submarine

Type Min. Max.

Size Pack assy M19622

Insert block

Insert block

Surface size Size Grommet

Box conn. MIL-Spec Slant sheet

DSS-2 0.370 0.390 2 17-0003 15/9 B 1 2-062 ½ MIL-DTL-915 8

DSS-3 0.480 0.500 4T 19-0001 20/12 30/12 B 1 2-065 ½ MIL-DTL-915 8

DSS-4 0.480 0.500 4T 19-0001 20/12 30/12 B 1 2-065 ½ MIL-DTL-915 8

DSWS-4 0.770 0.800 5 20-0001 30/20 E 2 2-071 1 MIL-DTL-915 7

FSS-2 0.480 0.500 4T 19-0001 20/12 30/12 B 1 2-065 ½ MIL-DTL-915 8

FSS-3 0.480 0.500 4T 19-0001 20/12 30/12 B 1 2-065 ½ MIL-DTL-915 8

FSS-4 0.600 0.625 4T 19-0004 20/15 30/15 C 2 2-068 ¾ MIL-DTL-915 8

JAS-250 1.260 2.480 MIL-DTL-915 9

MCSF-4 1.388 1.500 7 22-0002 60/38 P 6 2-099 1½ MIL-DTL-915 10

MSP 1.565 1.635 7 22-0003 60/40 R 7 2-101 2 MIL-DTL-915 67

MSPW 1.565 1.635 7 22-0003 60/40 R 7 2-101 2 MIL-DTL-915 66

MWF-7 0.480 0.500 3 18-0018 20/12 30/12 C 1 2-065 ½ MIL-DTL-915 58

MWF-10 0.605 0.635 4T 19-0004 20/16 30/16 D 2 2-068 ¾ MIL-DTL-915 58

MWF-14 0.605 0.635 4T 19-0005 20/16 30/16 D 2 2-068 ¾ MIL-DTL-915 58

MWF-19 0.710 0.745 4T 19-0007 30/18 E 2 2-071 ¾ MIL-DTL-915 58

MWF-24 0.800 0.836 5 20-0002 30/21 G 3 2-072 1 MIL-DTL-915 58

MWF-30 0.905 0.945 5 20-0005 30/24 40/24 J 3 2-074 1 MIL-DTL-915 58

MWF-37 1.005 1.045 5 20-0008 40/26 J 3 2-076 1¼ MIL-DTL-915 58

THOF-42 1.200 1.250 6 21-0004 40/30 L 4 2-094 1¼ MIL-DTL-915 6

THOF-400 2.680 2.800 9 24-0008 90/70 AA 3 MIL-DTL-915 6

THOF-500 2.920 3.100 120/75 BB 3½ MIL-DTL-915 6

TPUM-6 0.856 0.925 5 20-0004 30/23 G 3 2-074 1 MIL-DTL-915 79

TSP-11 0.680 0.730 4T 19-0007 30/17 D 2 2-070 ¾ MIL-DTL-915 22

TSP-31 0.982 1.062 5 20-0008 40/26 J 4 2-090 1¼ MIL-DTL-915 22

TSPA-11 0.730 0.785 4T 19-0007 30/19 E 2 2-071 1 MIL-DTL-915 22

TSPA-31 1.032 1.112 5 20-0008 40/28 K 4 2-091 1¼ MIL-DTL-915 22

TSS-2 0.385 0.400 2 17-0003 20/10 A 1 2-062 ½ MIL-DTL-915 8

TSS-3 0.480 0.500 4T 19-0001 20/12 30/12 B 1 2-065 ½ MIL-DTL-915 8

TSS-4 0.480 0.500 4T 19-0001 20/12 30/12 B 1 2-065 ½ MIL-DTL-915 8

1PR-A2OE 0.264 0.285 1 16-0005 15/7 20/7 1 2-061 MIL-DTL-915 81

1PR-16 0.380 0.400 2 17-0003 20/10 1 2-062 MIL-DTL-915 82

1O-16 0.380 0.400 2 17-0003 20/10 1 2-062 MIL-DTL-915 86

1SPR-16S 0.380 0.400 2 17-0003 20/10 1 2-062 MIL-DTL-915 89

1SWF-2 0.600 0.625 4T 19-0004 20/15 30/15 C 2 2-068 ¾ MIL-DTL-915 47

1TR-16 0.380 0.400 2 17-0003 20/10 1 2-062 MIL-DTL-915 87

2SPR-16 0.630 0.650 4T 19-0004 20/16 30/16 2 2-039 MIL-DTL-915 84

2SWF-3 0.600 0.625 4T 19-0004 20/15 30/15 D 2 2-068 ¾ MIL-DTL-915 48

2SWF-4 0.600 0.625 4T 19-0004 20/15 30/15 D 2 2-068 ¾ MIL-DTL-915 48

2SWF-7 0.780 0.815 5 20-0002 30/20 F 3 2-072 ¾ MIL-DTL-915 48

2SWF-24 1.190 1.250 6 21-0004 40/30 4 2-094 MIL-DTL-915 48

3PR-16 0.530 0.550 4T 19-0002 20/13 30/13 1 2-066 MIL-DTL-915 85

7PR-16 0.630 0.650 4T 19-0004 20/16 30/16 2 2-069 MIL-DTL-915 83

7SPR-16S 0.920 0.950 5 20-0005 30/24 40/24 3 2-074 MIL-DTL-915 88

7SS-2 0.600 0.625 4T 19-0004 20/15 30/15 C 2 2-068 ¾ MIL-DTL-915 8

DX-3 0.223 0.241 1 16-0005 15/6 20/6 A 1 2-061 ½ MIL-DTL-24640 1

DX-4 0.266 0.286 1 16-0005 15/7 20/7 A 1 2-061 ½ MIL-DTL-24640 1

NOTE:

1. Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and BX connectors shown on figures 3A2 through

3A9 and 3A24 through 3A31 are for MIL-DTL-915, MIL-DTL-24640, and MIL-DTL-24643 cable.

FIGURE 3A2. Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors.

Type Min. Max.

Size Pack assy M19622

Insert block

Insert block

Surface size Size Grommet

Box conn. MIL-Spec Slant sheet

DXOW-3 0.294 0.316 2 17-0001 15/8 20/8 A 1 2-062 ½ MIL-DTL-24640 19

DXOW-4 0.328 0.354 2 17-0002 15/8 20/8 A 1 2-062 ½ MIL-DTL-24640 19

DXW-3 0.239 0.257 1 16-0005 15/6 20/6 A 1 2-061 ½ MIL-DTL-24640 19

DXW-4 0.281 0.303 1 16-0006 15/7 20/7 A 1 2-061 ½ MIL-DTL-24640 19

FX-3 0.262 0.282 1 16-0006 15/7 20/7 A 1 2-061 ½ MIL-DTL-24640 3

FX-4 0.311 0.335 2 17-0002 15/8 20/8 A 1 2-062 ½ MIL-DTL-24640 3

FXOW-3 0.324 0.350 1 16-0006 15/8 20/8 1 2-062 ½ MIL-DTL-24640 21

FXOW-4 0.366 0.394 2 17-0003 20/10 1 2-062 ½ MIL-DTL-24640 21

FXW-3 0.266 0.286 1 16-0005 15/7 20/7 A 1 2-061 ½ MIL-DTL-24640 21

FXW-4 0.315 0.339 2 17-0002 15/8 20/8 A 1 2-062 ½ MIL-DTL-24640 21

MXCOW-7 0.340 0.366 2 17-0002 15/9 20/9 A 1 2-062 ⅜ MIL-DTL-24640 23

MXCOW-10 0.415 0.447 2 17-0004 20/11 B 1 2-063 ½ MIL-DTL-24640 23

MXCOW-14 0.440 0.474 3 18-0018 20/12 30/12 B 1 2-064 ½ MIL-DTL-24640 23

MXCOW-19 0.477 0.515 4T 19-0001 20/13 30/13 C 1 2-065 ½ MIL-DTL-24640 23

MXCOW-24 0.557 0.601 4T 19-0003 20/15 30/15 C 2 2-068 ¾ MIL-DTL-24640 23

MXCOW-30 0.584 0.630 4T 19-0005 20/16 30/16 C 2 2-068 ¾ MIL-DTL-24640 23

MXCOW-37 0.622 0.670 4T 19-0005 30/17 D 2 2-069 ¾ MIL-DTL-24640 23

MXCOW-44 0.697 0.751 4T 20-0001 30/19 E 2 2-071 1 MIL-DTL-24640 23

MXCOW-61 0.757 0.817 5 20-0002 30/20 F 3 2-072 1 MIL-DTL-24640 23

MXCW-7 0.295 0.319 2 17-0001 15/8 20/8 A 1 2-062 ⅜ MIL-DTL-24640 23

MXCW-10 0.375 0.405 2 17-0004 20/10 B 1 2-062 ½ MIL-DTL-24640 23

MXCW-14 0.402 0.434 3 18-0018 20/11 B 1 2-063 ½ MIL-DTL-24640 23

MXCW-19 0.440 0.474 3 18-0018 20/12 30/12 B 1 2-064 ½ MIL-DTL-24640 23

MXCW-24 0.520 0.560 4T 19-0003 20/14 30/14 C 1 2-067 ¾ MIL-DTL-24640 23

MXCW-30 0.547 0.589 4T 19-0003 20/14 30/14 C 1 2-067 ¾ MIL-DTL-24640 23

MXCW-37 0.584 0.630 4T 19-0005 20/16 30/16 C 2 2-068 ¾ MIL-DTL-24640 23

MXCW-44 0.656 0.708 4T 19-0006 30/17 D 2 2-070 ¾ MIL-DTL-24640 23

MXCW-61 0.729 0.785 5 20-0001 30/19 E 2 2-071 1 MIL-DTL-24640 23

MXO-10 0.349 0.377 3 18-0018 15/9 20/9 A 1 2-062 ⅜ MIL-DTL-24640 8

MXO-14 0.380 0.410 2 17-0004 20/10 B 1 2-063 ½ MIL-DTL-24640 8

MXSO-2 0.282 0.304 1 16-0005 15/7 20/7 A 1 2-061 ⅜ MIL-DTL-24640 10

MXSO-9 0.424 0.458 3 18-0018 20/11 B 1 2-064 ½ MIL-DTL-24640 10

MXSO-21 0.552 0.596 4T 19-0004 20/15 30/15 C 2 2-068 ½ MIL-DTL-24640 10

MXSO-37 0.644 0.694 4T 19-0007 30/17 D 2 2-070 ½ MIL-DTL-24640 10

MXSOW-2 0.282 0.304 1 16-0005 15/7 20/7 A 1 2-061 ⅜ MIL-DTL-24640 10

MXSOW-9 0.424 0.458 3 18-0018 20/11 B 1 2-064 ½ MIL-DTL-24640 10

MXSOW-21 0.552 0.596 4T 19-0004 20/15 30/15 C 2 2-068 ½ MIL-DTL-24640 10

MXSOW-37 0.644 0.694 4T 19-0007 30/17 D 2 2-070 ½ MIL-DTL-24640 10

TTX-3 0.296 0.320 2 17-0002 15/8 20/8 A 1 2-062 ⅜ MIL-DTL-24640 4

TTX-15 0.549 0.591 4T 19-0005 20/15 30/15 C 2 2-068 ½ MIL-DTL-24640 4

TTXOW-1½ 0.253 0.273 1 16-0004 15/6 20/6 A 1 2-061 ⅜ MIL-DTL-24640 24

TTXOW-3 0.333 0.359 2 17-0002 15/9 20/9 A 1 2-062 ⅜ MIL-DTL-24640 24

TTXOW-5 0.376 0.406 2 17-0003 20/10 B 1 2-063 ½ MIL-DTL-24640 24

NOTE:

1. Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and BX connectors shown on figures 3A2 through

3A9 and 3A24 through 3A31 are for MIL-DTL-915, MIL-DTL-24640, and MIL-DTL-24643 cable.

FIGURE 3A3. Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors.

Type Min. Max.

Size Pack assy M19622

Insert block

Insert block

Surface size Size Grommet

Box conn. MIL-Spec Slant sheet

TTXOW-15 0.556 0.600 4T 19-0004 20/15 30/15 C 2 2-068 ½ MIL-DTL-24640 24

TTXOW-20 0.614 0.662 4T 19-0005 20/16 30/15 D 2 2-069 ½ MIL-DTL-24640 24

TTXOW-30 0.717 0.772 5 20-0001 30/19 E 2 2-071 1 MIL-DTL-24640 24

TTXOW-40 0.823 0.887 5 20-0004 30/22 40/22 G 3 2-073 1 MIL-DTL-24640 24

TTXS-2 0.335 0.361 2 17-0003 15/9 20/9 A 1 2-062 ⅜ MIL-DTL-24640 5

TTXS-4 0.393 0.424 2 17-0004 20/10 B 1 2-063 ⅜ MIL-DTL-24640 5

TTXSO-2 0.386 0.416 2 17-0004 20/10 B 1 2-063 ½ MIL-DTL-24640 5

TTXSO-6 0.506 0.546 4T 19-0003 20/13 30/13 C 1 2-066 ¾ MIL-DTL-24640 5

TTXSO-8 0.587 0.633 4T 19-0005 20/15 30/16 D 2 2-068 ¾ MIL-DTL-24640 5

TTXSO-10 0.627 0.675 4T 19-0006 30/17 D 2 2-069 ¾ MIL-DTL-24640 5

TTXW-1½ 0.181 0.195 1 16-0004 15/4 20/4 A 1 2-061 ⅜ MIL-DTL-24640 24

TTXW-3 0.285 0.307 2 17-0001 15/7 20/7 A 1 2-061 ⅜ MIL-DTL-24640 24

TTXW-5 0.331 0.357 2 17-0002 15/8 20/8 A 1 2-062 ⅜ MIL-DTL-24640 24

TTXW-10 .0456 0.492 4T 19-0001 20/12 30/12 B 1 2-065 ½ MIL-DTL-24640 24

TTXW-15 0.527 0.569 4T 19-0003 20/14 30/14 B 1 2-067 ¾ MIL-DTL-24640 24

TTXW-20 0.577 0.621 4T 19-0005 20/15 30/15 C 2 2-068 ¾ MIL-DTL-24640 24

TTXW-30 0.684 0.738 4T 19-0007 30/18 D 2 2-071 ¾ MIL-DTL-24640 24

TTXW-40 0.790 0.852 5 20-0003 30/21 G 3 2-073 1 MIL-DTL-24640 24

TX-3 0.243 0.261 1 16-0005 15/6 20/6 A 1 2-061 ⅜ MIL-DTL-24640 2

TX-4 0.288 0.310 2 17-0001 15/7 20/7 A 1 2-061 ⅜ MIL-DTL-24640 2

TXOW-3 0.305 0.329 2 17-0002 15/8 20/8 A 1 2-062 ⅜ MIL-DTL-24640 20

TXOW-4 0.343 0.369 2 17-0002 15/9 20/9 A 1 2-062 ⅜ MIL-DTL-24640 20

TXW-3 0.246 0.266 1 16-0005 15/6 20/6 A 1 2-061 ⅜ MIL-DTL-24640 20

TXW-4 0.292 0.314 2 17-0002 15/7 20/7 A 1 2-062 ⅜ MIL-DTL-24640 20

1XMSO-7 0.344 0.370 2 17-0002 15/9 20/9 A 1 2-062 ⅜ MIL-DTL-24640 7

1XMSO-16 0.471 0.507 4T 19-0002 20/12 30/12 C 1 2-065 ½ MIL-DTL-24640 7

1XMSO-70 0.859 0.925 5 20-0006 30/23 J 3 2-074 1 MIL-DTL-24640 7

1XSOW-2 0.292 0.314 2 17-0001 15/7 20/7 A 1 2-062 ⅜ MIL-DTL-24640 14

1XSOW-14 0.470 0.506 4T 19-0001 20/12 30/12 C 1 2-065 ½ MIL-DTL-24640 14

1XSOW-20 0.542 0.584 4T 19-0003 20/14 30/14 C 1 2-067 ½ MIL-DTL-24640 14

1XSOW-30 0.614 0.662 4T 19-0005 20/16 30/16 D 2 2-069 ½ MIL-DTL-24640 14

2XAO-2 0.307 0.331 2 17-0001 15/8 20/8 A 1 2-062 ⅜ MIL-DTL-24640 6

2XAO-7 0.392 0.422 2 17-0004 20/10 B 1 2-063 ½ MIL-DTL-24640 6

2XAO-10 0.475 0.511 4T 19-0002 20/12 30/12 C 1 2-065 ½ MIL-DTL-24640 6

2XAO-18 0.567 0.611 4T 19-0004 20/15 30/15 C 2 2-068 ½ MIL-DTL-24640 6

2XAO-40 0.796 0.858 5 20-0004 30/21 G 3 2-073 ¾ MIL-DTL-24640 6

2XO-6 0.305 0.329 2 17-0001 15/8 20/8 A 1 2-062 ⅜ MIL-DTL-24640 12

2XO-18 0.417 0.449 3 18-0018 20/11 B 1 2-064 ½ MIL-DTL-24640 12

2XO-24 0.473 0.509 4T 19-0002 20/12 30/12 C 1 2-065 ½ MIL-DTL-24640 12

2XO-42 0.565 0.609 4T 19-0004 20/15 30/15 C 2 2-068 ½ MIL-DTL-24640 12

2XO-60 0.641 0.691 4T 19-0006 30/17 D 2 2-070 ¾ MIL-DTL-24640 12

2XO-77 0.728 0.785 5 20-0002 30/19 E 2 2-071 ¾ MIL-DTL-24640 12

2XOW-6 0.336 0.363 2 17-0002 15/9 20/9 A 1 2-062 ⅜ MIL-DTL-24640 17

NOTE:

1. Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and BX connectors shown on figures 3A2 through

3A9 and 3A24 through 3A31 are for MIL-DTL-915, MIL-DTL-24640, and MIL-DTL-24643 cable.

FIGURE 3A4. Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors.

Type Min. Max.

Size Pack assy M19622

Insert block

Insert block

Surface size Size Grommet

Box conn. MIL-Spec Slant sheet

2XOW-18 0.468 0.504 4T 19-0002 20/12 30/12 C 1 2-065 ½ MIL-DTL-24640 17

2XOW-24 0.546 0.588 4T 19-0004 20/14 30/14 C 1 2-067 ½ MIL-DTL-24640 17

2XOW-42 0.646 0.686 4T 19-0006 30/17 D 2 2-070 ½ MIL-DTL-24640 17

2XOW-60 0.744 0.802 5 20-0002 30/20 F 3 2-072 ¾ MIL-DTL-24640 17

2XOW-77 0.840 0.906 5 20-0005 30/23 G 3 2-074 ¾ MIL-DTL-24640 17

2XS-2 0.308 0.332 2 17-0002 15/8 20/8 A 1 2-062 ⅜ MIL-DTL-24640 9

2XS-3 0.325 0.350 2 17-0002 15/8 20/8 A 1 2-062 ½ MIL-DTL-24640 9

2XS-7 0.423 0.455 3 18-0018 20/11 B 1 2-063 ½ MIL-DTL-24640 9

2XS-10 0.537 0.579 4T 19-0004 20/14 30/14 C 1 2-067 ½ MIL-DTL-24640 9

2XS-14 0.582 0.627 4T 19-0005 20/15 30/15 D 2 2-068 ½ MIL-DTL-24640 9

2XS-19 0.644 0.694 4T 19-0007 30/17 D 2 2-070 ½ MIL-DTL-24640 9

2XS-24 0.758 0.818 5 20-0003 30/20 G 3 2-072 ¾ MIL-DTL-24640 9

2XS-30 0.804 0.866 5 20-0004 30/21 G 3 2-073 ¾ MIL-DTL-24640 9

2XSAOW-3 0.405 0.437 2 17-0004 20/11 B 1 2-063 ½ MIL-DTL-24640 15

2XSAOW-7 0.510 0.550 4T 19-0002 20/13 30/13 C 1 2-066 ½ MIL-DTL-24640 15

2XSAOW-10 0.631 0.681 4T 19-0006 30/17 D 2 2-070 ½ MIL-DTL-24640 15

2XSAOW-14 0.689 0.743 5 20-0001 30/18 D 2 2-071 ½ MIL-DTL-24640 15

2XSAOW-19 0.757 0.817 5 20-0003 30/20 F 3 2-072 ¾ MIL-DTL-24640 15

2XSAOW-24 0.884 0.952 5 20-0006 30/24 40/24 J 3 2-075 ¾ MIL-DTL-24640 15

2XSAOW-30 0.941 1.020 5 20-0007 30/24 40/24 J 3 2-076 1⅜ MIL-DTL-24640 15

2XSAOW-37 1.010 1.090 5 20-0010 40/26 K 4 2-090 1⅜ MIL-DTL-24640 15

2XSAW-3 0.368 0.396 2 17-0004 20/10 B 1 2-062 ½ MIL-DTL-24640 15

2XSAW-7 0.461 0.497 4T 19-0001 20/12 30/12 B 1 2-065 ½ MIL-DTL-24640 15

2XSAW-14 0.641 0.691 4T 19-0006 30/17 D 2 2-069 ½ MIL-DTL-24640 15

2XSAWA-3 0.418 0.446 2 17-0004 20/11 B 1 2-063 ½ MIL-DTL-24640 15

2XSAWA-7 0.511 0.547 4T 19-0001 20/13 30/13 C 1 2-066 ½ MIL-DTL-24640 15

2XSAWA-14 0.691 0.741 4 19-0006 30/18 E 2 2-071 ½ MIL-DTL-24640 15

2XSO-2 0.380 0.410 2 17-0004 20/10 B 1 2-063 ½ MIL-DTL-24640 9

2XSO-7 0.474 0.510 4T 19-0002 20/12 30/12 C 1 2-065 ½ MIL-DTL-24640 9

2XSO-10 0.594 0.640 4T 19-0005 20/16 30/16 D 2 2-069 ½ MIL-DTL-24640 9

2XSO-14 0.636 0.686 4T 19-0006 30/17 D 2 2-070 ½ MIL-DTL-24640 9

2XSO-19 0.709 0.765 5 20-0001 30/19 E 2 2-071 ¾ MIL-DTL-24640 9

2XSO-30 0.869 0.937 5 20-0005 30/23 G 3 2-074 ¾ MIL-DTL-24640 9

2XSOW-3 0.487 0.525 4T 19-0002 20/13 30/13 C 1 2-065 ½ MIL-DTL-24640 16

2XSOW-7 0.606 0.656 4T 19-0005 20/16 30/16 D 2 2-069 ½ MIL-DTL-24640 16

2XSOW-12 0.802 0.864 5 20-0004 30/21 G 3 2-073 ¾ MIL-DTL-24640 16

2XSOW-19 0.938 1.010 5 20-0007 30/24 40/24 J 3 2-076 1⅜ MIL-DTL-24640 16

2XSOW-30 1.180 1.270 6 21-0005 40/32 60/32 M 5 2-095 1⅜ MIL-DTL-24640 16

2XSW-1 0.240 0.258 1 16-0005 15/6 20/6 A 1 2-051 ⅜ MIL-DTL-24640 16

2XSW-3 0.436 0.470 3 18-0018 20/12 30/12 B 1 2-064 ⅜ MIL-DTL-24640 16

2XSW-7 0.573 0.617 4T 19-0005 20/15 30/15 C 2 2-068 ½ MIL-DTL-24640 16

2XSXO-4 0.333 0.359 2 17-0002 15/9 20/9 A 1 2-062 ⅜ MIL-DTL-24640 13

3XS-7 0.601 0.647 4T 19-0005 20/16 30/16 D 2 2-069 ½ MIL-DTL-24640 11

3XSOW-3 0.519 0.559 4T 19-0003 20/14 30/14 C 1 2-067 ½ MIL-DTL-24640 18

3XSOW-7 0.659 0.711 4T 19-0007 30/17 D 2 2-070 ½ MIL-DTL-24640 18

3XSOW-10 0.835 0.901 5 20-0005 30/22 40/22 G 3 2-074 ¾ MIL-DTL-24640 18

NOTE:

1. Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and BX connectors shown on figures 3A2 through

3A9 and 3A24 through 3A31 are for MIL-DTL-915, MIL-DTL-24640, and MIL-DTL-24643 cable.

FIGURE 3A5. Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors.

Type Min. Max.

Size Pack assy M19622

Insert block

Insert block

Surface size Size Grommet

Box conn. MIL-Spec Slant sheet

3XSOW-14 0.898 0.968 5 20-0006 30/24 40/24 J 3 2-075 ¾ MIL-DTL-24640 18

3XSOW-19 1.010 1.090 5 20-0010 40/27 K 4 2-091 1⅜ MIL-DTL-24640 18

3XSOW-24 1.200 1.300 6 21-0005 40/32 60/32 M 5 2-095 1⅜ MIL-DTL-24640 18

3XSW-3 0.472 0.508 4T 19-0001 20/11 B 1 2-065 ½ MIL-DTL-24640 18

3XSW-7 0.620 0.668 4T 19-0005 20/16 30/16 D 2 2-069 ½ MIL-DTL-24640 18

3XSW-10 0.803 0.865 5 20-0004 30/21 G 3 2-073 ¾ MIL-DTL-24640 18

3XSW-14 0.873 0.941 5 20-0005 30/23 G 3 2-074 ¾ MIL-DTL-24640 18

7XW-3 0.315 0.339 2 17-0002 15/8 20/8 A 1 2-062 ⅜ MIL-DTL-24640 22

7XW-4 0.374 0.404 2 17-0004 15/9 B 1 2-062 ½ MIL-DTL-24640 22

LS1SAU-44 0.910 1.040 5 20-0006 30/24 40/24 J 3 2-074 1 MIL-DTL-24643 41

LS1SMU-5 0.465 0.500 4T 19-0001 20/12 30/12 B 1 2-065 ½ MIL-DTL-24643 40

LS1SMWU-70 1.465 1.555 7 22-0008 60/38 P 6 2-100 2 MIL-DTL-24643 47

LS1SU-36 0.910 0.985 5 20-0005 30/24 40/24 J 1 MIL-DTL-24643 42

LS1SU-60 1.210 1.310 6 21-0004 40/32 60/32 M 5 2-096 1¼ MIL-DTL-24643 42

LS1SWU-2 0.430 0.455 2 17-0004 20/11 B 1 2-063 ½ MIL-DTL-24643 30

LS1SWU-14 0.825 0.870 5 20-0003 30/22 40/22 G 3 2-073 1 MIL-DTL-24643 30

LS1SWU-20 0.970 1.030 5 20-0007 40/26 J 3 2-076 1¼ MIL-DTL-24643 30

LS1SWU-30 1.135 1.2 6 21-0003 40/30 L 4 2-094 1¼ MIL-DTL-24643 30

LS1S50MU-16 0.760 0.825 5 20-0002 30/20 G 3 2-072 ¾ MIL-DTL-24643 28

LS1S50MU-20 0.835 0.905 5 20-0004 30/22 40/22 G 3 2-074 ¾ MIL-DTL-24643 28

LS1S50MU-40 1.095 1.185 6 21-0001 40/30 L 4 2-094 1 MIL-DTL-24643 28

LS1S50MU-70 1.465 1.555 7 22-0001 60/38 P 6 2-100 1½ MIL-DTL-24643 28

LS1S50MUS-16 0.820 0.885 5 20-0004 30/22 40/22 G 3 2-073 ¾ MIL-DTL-24643 28

LS1S50MUS-20 0.895 0.965 5 20-0005 30/24 40/24 J 3 2-075 ¾ MIL-DTL-24643 28

LS1S50MUS-40 1.155 1.245 6 21-0003 40/30 L 4 2-094 1 MIL-DTL-24643 28

LS1S50MUS-70 1.525 1.615 7 22-0003 60/40 P 7 2-101 1½ MIL-DTL-24643 28

LS1S75MU-8 0.950 1.030 5 20-0007 40/26 J 3 2-076 1 MIL-DTL-24643 39

LS2AU-40 1.320 1.370 6 21-0005 40/34 60/34 M 5 2-096 1½ MIL-DTL-24643 27

LS2AUS-40 1.380 1.430 7 22-0001 60/36 N 6 2-098 1½ MIL-DTL-24643 27

LS2CS-6 0.400 0.430 2 17-0004 20/10 B 1 2-063 ⅜ MIL-DTL-24643 58

LS2CS-18 0.550 0.590 4T 19-0003 20/14 30/14 C 1 2-067 ½ MIL-DTL-24643 58

NOTE:

1. Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and BX connectors shown on figures 3A2 through

3A9 and 3A24 through 3A31 are for MIL-DTL-915, MIL-DTL-24640, and MIL-DTL-24643 cable.

FIGURE 3A6. Cable assignment to steel, aluminum, and nylon stuffing tubes, MCP blocks, and box connectors.

Type Min. Max.

Size Pack assy M19622

Insert block

Insert block

Surface size Size Grommet

Box conn. MIL-Spec Slant sheet

LS2CS-42 0.750 0.800 5 20-0002 30/20 E 2 2-071 ¾ MIL-DTL-24640 58

LS2CS-60 0.880 0.930 5 20-0005 30/23 G 3 2-074 ¾ MIL-DTL-24640 58

LS2CS-77 1.000 1.070 5 20-0009 40/26 K 4 2-090 1 MIL-DTL-24640 58

LS2SJ-7 0.600 0.615 4T 19-0003 20/15 30/15 C 2 2-068 ¾ MIL-DTL-24640 43

LS2SJ-9 0.525 0.545 4T 19-0001 20/13 30/13 C 1 2-066 ½ MIL-DTL-24640 43

LS2SJ-11 0.447 0.460 2 17-0004 20/11 B 1 2-064 ½ MIL-DTL-24640 43

LS2SJ-12 0.417 0.430 2 17-0002 20/10 A 1 2-063 ½ MIL-DTL-24640 43

LS2SJ-14 0.337 0.350 1 16-0006 15/8 20/8 A 1 2-062 ½ MIL-DTL-24640 43

LS2SJ-16 0.309 0.325 1 16-0004 15/8 20/8 A 1 2-062 ½ MIL-DTL-24640 43

LS2SJ-18…