Text version
N32205-18-R-4006
USNS JOHN LENTHALL (TAO-189)
REQUEST FOR SPECIFICATION CLARIFICATION
RFC 020
NAME OF CONTRACTOR: ______________________
SPECIFICATION ITEM NO.: ____501 _________________
PARAGRAPH / SECTION NO:___5.1_________________
TITLE: ___No. 3 SSDG Resilient Engine Mount Replacement____________
QUESTION:
Paragraph 5.1 of WI 501 says this item is to be worked in conjunction with 501 No. 3 SSDG Overhaul, 502 No. 3 SSDG Turbocharger Overhaul and 504 SSDG Local Control Panel Replacement. Item 501 is SSDG Resilient Engine Mount Replacement, 502 is No. 3 Vulkan Coupling Replacement and 504 is Evaporator Replacement. Please clarify.
ANSWER:
See Amendment 0004 and ARMDEC for revised WI 501A.