N3220518R4006
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION C - DESCRIPTIONS AND SPECIFICATIONS
The following have been modified:
C – 2 List of Standard Work Items included for this solicitation:
| ITEM | TITLE | CATEGORY |
| 000 | GENERAL REQUIREMENTS |
| 001 | INTENT, SCOPE, GENERAL CONDITIONS AND DEFINITIONS | NSP | |||||||
| 002 | TECHNICAL AND MANUFACTURER’S REPRESENTATIVES | NSP | |||||||
| 003 | APPROACH, BERTH AND MOORING REQUIREMENTS | NSP | |||||||
| 004 | TESTING AND QUALITY ASSURANCE | NSP | |||||||
| 005 | ELECTRICAL SAFETY PROCEDURE REQUIREMENTS | NSP | |||||||
| 006 | HEAVY WEATHER PLAN | NSP | |||||||
| 007 | COLD WEATHER PLAN | NSP | |||||||
| 010 | FURNISH OFFICE FOR OVERHAUL MANAGEMENT TEAM (OMT) | A | |||||||
| 011 | FURNISH GENERAL SERVIES (TAO) | A | |||||||
| 012 | TELEPHONE SERVICES | A | |||||||
| 013 | PROJECT PLANNING AND PRODUCTION STATUS MONITORING | ||||||||
| REPORTS | A | ||||||||
| 014 | PREPERATION OF WEIGHT AND MOMENT REPORT | A | |||||||
| 015 | INTEGRATED LOGISTICS AND GFM SUPPORT REQUIREMENTS | A | |||||||
| 016 | FIRE PROTECTION AND SHIP’S STORES | A | |||||||
| 017 | HANDLING SHIP’S STORES | A | |||||||
| 018 | DELIVERY AND REDELIVERY OF VESSEL | A | |||||||
| 019 | SHIPBOARD ACCESS AND SECURITY | A | |||||||
| 020 | GAS FREE CERTIFICATES | A | |||||||
| 021 | CLEAN AND GAS FREE TANKS, VOIDS, COFFERDAMS AND SPACES | A | |||||||
| 022 | DOCK TRIALS AND SEA TRIAL | A | |||||||
| 023 | HAZARDOUS WASTE DISPOSAL AT A CONTRACTOR’S FACILITY | A | |||||||
| 024 | PHYSICAL SECURITY AT CONTRACTOR’S FACILITY | NSP | |||||||
| 025 | PHYSICAL SECURITY AT CONTRACTOR’S FACILITY | B | |||||||
| 030 | CONTINUATION OF SERVICES | B |
100 HULL STRUCTURE
| 101 | NON-DESTRUCTIVE TESTING (NDT) KINGPOST AREAS (ABS) | A | |||||
| 102 | DECK NON-SKID RENEWAL | A | |||||
| 103A | DFM CONTAMINATED TANK BLASTING AND RECOATING | A | |||||
| 104A | JP-5 CONTAMINATED TANK BLASTING AND RECOATING | A | |||||
| 105A | STRUCTURAL STEEL REPAIRS | A | |||||
| 106A | STATION NO. 4 & 6 KINGPOST FRACTURE T-ALT | A | |||||
| 107B | TANK DECK CABLEWAY SHIELDS AND BRACKETS BLASTING AND | ||||||
| RECOATING | A | ||||||
| 108 | TANK DECK LIGHTING BRACKET REPLACEMENT | A | |||||
| 109A | CARGO POTABLE TANKS PAINT AND COATING | A | |||||
| 110A | PUMP ROOM BILGE PRESERVATION | A | |||||
| 111A | ULTRASONIC THICKNESS GAUGING | A | |||||
| 112A | STEEL DECK OVER FREEZER BOX REPLACEMENT | A | |||||
| 113A | EVAPORATOR STEEL DECK REPLACEMENT | B |
200 MACHINERY, PROPULSION
| 201B | MAIN ENGINE 12K OVERHAUL | A | |
| 202 | MAIN REDUCTION GEAR ANNUAL INSPECTION | A |
300 ELECTRICAL
| 301 | SWITCHBOARDS AND MOTOR CONTROLLERS CLEANING | A | |||
| 302 | CIRCUIT BREAKER INSPECTION AND REPAIR | A | |||
| 303 | RECONDITION AC MOTORS | A | |||
| 304 | WEATHER DECK KICK PIPE REPAIRS | A | |||
| 305 | CABLE BULKHEAD COLLAR MAGNA ROCK REPLACEMENT | A |
400 COMMUNICATION & NAVIGATION EQUIPMENT
| 401 | GMDSS RECERTIFICATION ANNUAL | A | |||
| 402 | RADAR/ECDIS PREVENTATIVE MAINTENANCE | A | |||
| 403 | NAVIGAT X GYRO SYSTEM PREVENTATIVE MAINTENANCE | A | |||
| 404 | MAGNETIC COMPASS ANNUAL | A | |||
| 405 | SVDR RECERTIFICATION ANNUAL | A | |||
| 406A | 10315U REMOTE SWITCH CONTROL UNIT GROOM | A | |||
| 407 | REPLACE ORBIT TVDTS ANTENNA AND SYSTEM | A | |||
| 408A | ANTENNA PHOTOGRAPHS | A | |||
| 409 | XLI SYSTEM COAXIAL CABLES REMOVAL & REPLACEMENT | A |
500 MACHINERY, AUXILIARY
| 501A | SSDG NO. 3 RESILIENT MOUNT REPLACEMENT | A | ||||||||
| 502 | NO. 3 VULKAN COUPLING REPLACEMENT | A | ||||||||
| 503A | DFM CARGO PIPING REPLACEMENT | A | ||||||||
| 504A | EVAPORATOR REPLACEMENT TRANS-ALTS | A | ||||||||
| 505 | PRESSURE VESSEL INSPECTION AND HYDRO (ABS) | A | ||||||||
| 506A | VESSEL RELIEF VALVE OVERHAUL | A | ||||||||
| 507 | CLAYTON BOILER PM | A | ||||||||
| 508A | SMOKE INDICIATING SYSTEM T-ALT | 914 | A | |||||||
| 509 | VAF CARGO OIL CONTENT MONITOR INSTALLATION I T-ALT | A | ||||||||
| 510 | REFRIDGERATION & AIR CONDITIONING SYSTEMS REPAIR & | |||||||||
| GROOM | A | |||||||||
| 511 | ENGINE ROOM OIL CONTENT MONITOR CALIBRATION | A | ||||||||
| 512A | ARMORY AC REPLACEMENT | A | ||||||||
| 513 | ERC AC REPLACEMENT | A | ||||||||
| 514A | CT WINCH 1, 5 & 6 REPAIR | A | ||||||||
| 515 | INCINERATOR INSPECTION AND MAINTENANCE | A | ||||||||
| 516A | BOILER UPTAKE CLEANING | A | ||||||||
| 517A | GAUGE, METER, TEST & MEASURING EQUIPMENT CALIBRATION | A | ||||||||
| 518 | SEWAGE PIPING ACID FLUSH | A | ||||||||
| 519A | REDUCTION GEAR LUBE OIL COOLER CLEANING | A | ||||||||
| 520A | MAIN ENGINE LUBE OIL COOLER CLEANING | A |
600 OUTFITTING, FURNISHING & HABITABILITY
| 601 | ANNUAL INSPECTION & REPAIR OF FIRE FIGHTING EQUIPMENT | A | ||||
| 602 | ANNUAL INSPECTION OF FIRE AND AFFF HOSES | A | ||||
| 603 | ANNUAL LIFERAFT RECERTIFICATION | A | ||||
| 604 | INSPECTION & REPAIR OF FASSMER LIFEBOATS | A | ||||
| 605 | INSPECTION & REPAIR OF RESCUE BOATS | A | ||||
| 606 | PORT RHIB DAVIT ANNUAL SERVICING | A | ||||
| 607 | INSPECTION OF LIFEBOAT DAVIT WINCHES (ABS) | A | ||||
| 608 | MRD 5850 DAVIT INSPECTION/REPAIR CERTIFICATION (ABS) | A | ||||
| 609 | ANNUAL SCBA COMPRESSOR/REFILL STATION SERVICING | A | ||||
| 610 | ANNUAL INSPECTION OF SCBA EQUIPMENT | A | ||||
| 611 | ANNUAL PERSONNEL ELEVATOR RECERTIFICATION | A | ||||
| 612 | ANNUAL SERVICING OF IMMERSION SUITS | A | ||||
| 613 | FREEZER BOX INSULATION REPLACEMENT | A | ||||
| 614 | DEEP FAT FRYER REPLACEMENT | A | ||||
| 615 | ANNUAL INSPECTION OF ACCOMMODATION LADDERS (ABS) | A | ||||
| 616A | T-AO AFFF CONVERSION, NATIONAL TO ANSULITE 3X3 | A |
800 HEATING, VENTILATION AND AIR CONDITIONING
801 VENTILATION SYSTEMS DAMPERS A
1000 UNREP EQUIPMENT
| 1001 | SLIDING BLOCK BUMPER REPLACEMENT | A | |||
| 1002 | WINCH ELECTRIC MOTOR CLASS “B” OVERHAUL | A | |||
| 1003 | SLIDING BLOCK CHAIN REPLACEMENT | A | |||
| 1004 | HIGH PRESSURE AIR RELIEF VALVE CALIBRATION | A | |||
| 1005 | SADDLE WINCH SHAFT REPLACEMENT/REPAIR | A | |||
| 1006A | ANTI-SLACK DEVICE (ASD) FRAME AND FOUNDATION | ||||
| REFURBISHMENT | A | ||||
| 1007 | REFURBISH ANTI-SLACK DEVICE (ASD) FRAME AND FOUNDATION | A | |||
| 1008A | WINCH CONTROL BOOTH WINDOW AND STEEL REPLACEMENT | A |