The file's text, extracted by GovTribe without its formatting.
N32205-17-R-4205
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION C - DESCRIPTIONS AND SPECIFICATIONS
The following have been modified:
C – 2 List of Standard Work Items included for this solicitation:
| Work Item |
| Work Item Title |
| Category |
000 GENERAL REQUIREMENTS
| 001 |
| Intent, Scope, General Requirements, And Definitions |
| NSP |
| 002 |
| Technical And Manufacturer’s Representatives |
| NSP |
| 003 |
| Approach, Berth, And Mooring Requirements |
| NSP |
| 004 |
| Testing And Quality Assurance |
| NSP |
| 005 |
| Electrical Safety Procedure Requirements |
| NSP |
| 006 |
| Heavy Weather Plan |
| NSP |
| 007 |
| Cold Weather Plan |
| NSP |
| 0010 |
| Furnish Office For Overhaul Management Team (OMT) |
| A |
| 0011 |
| Furnish General Services (T-AKE) |
| A |
| 0012 |
| Telephone Services |
| A |
| 0013 |
| Project Planning And Production Status Monitoring Reports |
| A |
| 0014 |
| Preparation Of Weight And Moment Report |
| A |
| 0015 |
| Integrated Logistics And GFM Support Requirements |
| A |
| 0016 |
| Fire Protection And Ship's Safety Program |
| A |
| 0017 |
| Handling Ship's Stores |
| A |
| 0018 |
| Delivery And Redelivery Of The Vessel |
| A |
| 0019 |
| Shipboard Access And Security |
| A |
| 0020 |
| Gas Free Certificates |
| A |
| 0021 |
| Clean And Gas Free Tanks, Voids, Cofferdams & Spaces |
| A |
| 0022 |
| Dock Trials And Sea Trials |
| A |
| 0023 |
| Hazardous Waste Disposal At a Contractor's Facility |
| A |
| 0024 |
| Physical Security At Private Contractor’s Facility |
| NSP |
| 0025 |
| Physical Security At Private Contractor’s Facility In Force Protection Conditions Bravo - Delta |
| B |
| 0030 |
| Continuation of Services |
| B |
100 HULL STRUCTURAL
| 0108 |
| Tank Boundary Testing and Structural Survey (ABS) |
| A |
| 0141 |
| Replace Mooring line fairleads (correct material discrepancy) |
| A |
| 0142 |
| Blast And Coat Tanks (food waste and grey water) |
| A |
| 0143 |
| Forward Crane Boom Rest Pedestal Repair (TALT 402) |
| A |
200 MACHINERY PROPULSION
| 0201 |
| Propulsion Motor and Cooler Cleaning |
| A |
| 0202 |
| 5 year Main Engine Flex Hose Replacement |
| A |
| 0205 |
| AUTOMATION AND PROP ANNUAL TESTING_REV - |
| A |
| 0206 |
| MDG Vulkan Coupling Inspection |
| A |
| 0210 |
| MDG 12,000 HR Overhaul |
| A |
| 0231 |
| Splash Oil and Test Circuit Modification (TALT-381R) |
| A |
300 ELECTRICAL
| 0301 |
| Cleaning Main Generators And Propulsion Control System (5-YR) |
| A |
| 0303 |
| High Voltage, Ship's Service, And Emergency Switchboard Inspection And Cleaning |
| A |
| 0331 |
| Bilge Alarms Distribution Trunks (TALT 393) |
| A |
| 0342 |
| Shipyard support for installation of AESS UPS (TALT 434) |
| A |
400 Communication and Navigational Aids
| 0401 |
| Bridge Equipment Annual Service |
| A |
OE-570/WSC Antenna System Maintenance Automated Digital Network System (ADNS-SFF) Support REV- A A
| 0441 |
| NAVMACSII Shipyard Industrial Assistance (TALT 454) |
| A |
| 0442 |
| VDR Generation 4 Upgrade (TALT 413) |
| A |
500 Machinery, Auxiliary Systems
| 0501 |
| Firefighting System Annual Inspection |
| A |
| 0502 |
| SCBA Annual Inspection |
| A |
| 0503 |
| SCBA Air Compressor And Filling Station Inspection And Maintenance |
| A |
| 0504 |
| 5 Yr. Crane Retesting Survey and Hose Replacement (ABS) |
| A |
| 0507 |
| 5 year Emergency Diesel Flex Hose Replacement |
| A |
| 0510 |
| Oil Content Meter Calibration |
| A |
| 0512 |
| Magazine Sprinkler Gauge Calibration |
| A |
| 0513 |
| Gauge Calibration (INCLUDE GPETE) |
| A |
| 0514 |
| Relief Valve Testing |
| A |
| 0515 |
| Testing And Certification Of HP Air Receivers |
| A |
| 0516 |
| Sewage System Piping Flush |
| A |
| 0519 |
| LTFW Cooler Cleaning and Regasketing |
| A |
| 0520 |
| HTFW Cooler Cleaning and Regasketing |
| A |
| 0528 |
| Magazine control valve inspection/overhaul |
| A |
| 0551 |
| Miscellaneous Pipe Repair - Replacement (VR16-019 VR16-018) |
| A |
| 0552 |
| Replace HP Air Fittings |
| A |
| 0553 |
| HTFW Pump overhaul |
| A |
| 0554 |
| LTFW Pump overhaul and motor replace |
| A |
| 0555 |
| Fire Charging Pump Overhaul |
| A |
| 0556 |
| Repair Miscellaneous Valves |
| A |
| 0557 |
| Repair Pressure Regulating Valves |
| A |
| 0558 |
| Replace Cascade Restrictive Orifice Device (CORD) |
| A |
| 0559 |
| Install drains at RO unit (VR16-002) |
| A |
| 0560 |
| Repair MSD discharge chamber TLI (VR16-017) |
| A |
| 0561 |
| Replace 01 Level roller door motor operators |
| A |
| 0562 |
| Correct Potable Water Pump Short Cycle (VR16-016) |
| A |
| 0563 |
| #2 fire sprinkling pump overhaul |
| A |
| 0564 |
| #1 Dewater/Ballast Pump Overhaul |
| A |
| 0567 |
| MARPOL Annex VI Fuel Sampling (TALT 377) |
| A |
| 0568 |
| MMR AFFF System Piping Replacement (TALT 394) |
| A |
| 0569 |
| Forward AFFF System Piping Replacement (TALT 394) |
| A |
600 Outfit, Furnishings and Habitability
| 0602 |
| Accommodation Ladder Inspection And Load Testing |
| A |
| 0603 |
| FASSMER Lifeboat and Davits Inspections |
| A |
| 0604 |
| FASSMER Rescue Boat and Davits Inspections |
| A |
| 0605 |
| Life Raft certification |
| A |
| 0606 |
| Renew Flight Deck Non-skid |
| A |
| 0607 |
| Renew hanger bay Non-skid |
| A |
| 0641 |
| Lagging And Insulation Repair |
| A |
| 0643 |
| Replace Deck Covering In Waste Processing Room |
| A |
| 0644 |
| Replace Deck Covering In Fast Food Serving Line Annex |
| A |
| 0645 |
| Replace Deck Covering In Galley |
| A |
| 0649 |
| Preservation Of Machinery Space Fan Rooms |
| A |
| 0652 |
| Galley Serving Window Repair (VR-16-021) |
| A |
700 Sponsor Equipment
800 Heating, Ventialtion, and Air Conditioning
| 0801 |
| Galley and Laundry Exhaust Duct Cleaning |
| A |
| 0841 |
| Replace Heaters AC741 and AC732 |
| A |
900 Drydocking And Undocking
| 0901 |
| Dry-Docking And Undocking Ship |
| A |
| 0902 |
| Additional Dock days |
| B |
| 0903 |
| Propeller Shaft And Stern Tube Inspection |
| A |
| 0905 |
| Bow Thruster 5 Year Maintenance |
| A |
| 0908 |
| Renew Seachest, Rope Guard, And Bow Thruster Zincs |
| A |
| 0909 |
| Anchor and Anchor Chain Ranging |
| A |
| 0910 |
| Overhaul Sea Valves |
| A |
| 0911 |
| Inspect And Repair Cathodic Protection |
| A |
| 0913 |
| Renew Waster Pieces |
| A |
| 0916 |
| Underwater Hull Cleaning And Painting |
| A |
| 0941 |
| Freshwater (Closed Loop) Stern Tube Lubrication System (TALT403) |
| A |
| 0952 |
| Restore draft markings on stern |
| A |
1000 Underway Replenishment Gear
| 1001 |
| Sliding Block Hoist Chain Replacement |
| A |
| 1006 |
| E-STREAM Upgrade Station 6 Rev - (04-May-16) |
| A |
(End of Summary of Changes) image1.wmf