GULF PINES - E 2nd St Improvements - CIVIL for BID (2026-07-20).pdf

PDF 35 MB Posted

Attached to
GULF PINES IMPROVEMENT PROJECT
Solicitation number
2026-0811
Issued by
Baldwin County, Alabama

About this file

This is a sealed bid solicitation issued by the City of Gulf Shores, Alabama for the E 2nd Street Improvements project, a comprehensive roadway reconstruction and infrastructure upgrade. The project encompasses removal and replacement of the existing E 2nd Street roadway section between E 22nd Avenue and E 23rd Avenue, including construction of asphalt paving (5.44 inches of Superpave bituminous concrete per ALDOT standards), concrete sidewalks and driveways, median construction, on-street parking areas, and stormwater drainage infrastructure consisting of 18- to 30-inch diameter piping systems. The scope further includes grading and site preparation, hardscape and landscape elements with approximately 32,173 square feet of turf installation and tree and shrub plantings, site furnishings, and relocation of existing 6-inch and 12-inch water mains with portions to be abandoned in place and connection of a new 12-inch waterline per Gulf Shores Utilities coordination. The bid includes 226 line items covering site work, drainage, concrete work, utility adjustments, landscape items, and alternate bid options for the E 22nd Avenue intersection. All work must comply with geotechnical recommendations from reports dated April 3 and June 11, 2026. Sealed bids are due August 11, 2026 at 2:00 p.m., with a mandatory pre-bid conference scheduled for August 4, 2026 at 10:00 a.m.; bids from non-attending bidders will be rejected. Construction is scheduled to commence September 8, 2026, with a contract term of 120 calendar days from Notice to Proceed.

Qualified contractors must hold an Alabama contractor's license for bids exceeding $50,000 and must provide a bid bond of 5 percent of the contract amount or $10,000 (whichever is lesser), a performance bond equal to 100 percent of the contract amount, and a labor and materials bond of at least 50 percent. Monthly payments are made within 30 days of approval with 2.5 percent retainage held until final completion. Liquidated damages are assessed at $500 per day for work not completed within the contract term. All contractors must be enrolled in E-Verify and submit notarized affidavits confirming compliance with the Beason-Hammon Alabama Taxpayer and Citizen Protection Act. Insurance requirements include Commercial General Liability ($1 million each occurrence, $2 million aggregate), Business Automobile Liability ($1 million each occurrence), Worker's Compensation, and Commercial Umbrella/Excess Liability ($5 million each occurrence and aggregate), with the City designated as Additional Insured. Contractors are required to use Procore as the mandatory project management platform at no cost. Questions regarding the bid are due August 4, 2026.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CO

VE

R

SH

EE

T

EA

ST

ND

S

TR

EE

T

IM

PR

OV

EM

EN

TS

CI

TY

O F

GU

LF

S

HO

RE

S

Ji n ri gh t

A ss o ci at es

D ev el o p m en t

E n gi n ee rs

G re en o R o ad

N o rt h

F ai rh o p e, A la b am a

P .O

B o x ai rh o p e, A la b am a

P h o n e:

-3 ax (2

-3 ja d en gi n ee rs .c o m

A

L

C A

-3 -E

GULF PINES – E 2ND ST IMPROVEMENTS

(FROM E 22ND AVE TO E 23RD AVE)

CITY OF GULF SHORES, ALABAMA

GRADE, DRAIN, BASE AND PAVE

JULY 2026

INDEX TO SHEETS:

SHEET DESCRIPTION

VICINITY MAP

SITE

NOT TO SCALE

Professional Land Surveyors

SURVEY PROVIDED BY:

Wattier Surveying, Inc.

CITY OF GULF SHORES

205 CLUBHOUSE DRIVE, STE B

GULF SHORES, ALABAMA 36547

PREPARED FOR:

NO CONSTRUCTION AND/OR LAND DISTURBANCE, EXCEPT THOSE NECESSARY TO INSTALL THE

BMP'S, SHALL BEGIN ON THIS PROJECT UNTIL THE BMP PLAN HAS BEEN INSTALLED AND

APPROVED BY THE CITY/COUNTY.

NOTE:

UTILITY INFORMATION

CONTRACTOR SHALL HAVE ALL EXISTING BURIED UTILITIES

"LINE SPOTTED" BY CALLING 1-800-292-8925 (ALABAMA ONE-CALL)

OR BY CONTACTING LOCAL UTILITY COMPANIES

WATER/ SEWER:

GULF SHORES UTILITIES

RHONDA BUTLER - GENERAL MANAGER

(251) 968-6323 ext 3336 gsurbutler@gmail.com

1629 EAST 1ST ST, GULF SHORES, AL 36542

POWER:

BALDWIN EMC

KEN PIMPERL - (251) 989-0220

19600 STATE HIGHWAY 59, SUMMERDALE, AL 36580

GAS:

RIVIERA UTILITIES

JAMES WALLACE - (251) 943-5001

413 EAST LAUREL AVE, FOLEY, AL 36535

FIBER/ OTHER

COMMUNICATION:

BRIGHTSPEED

FORREST CHERNEY - (980) 376-1408

1120 SOUTH TRYON ST, SUITE 700, CHARLOTTE, NC 28203

C1 C2 C3 C4 C5 C6 C7-C8 C9 C10 C11-C12 C13 C14-C20 C21-C24 C25 C26 C27-30

FOLLOWING SHEETS (BY OTHERS) MAY NOT BE INCLUDED WITHIN THIS SET

COVER SHEET

CIVIL CONSTRUCTION NOTES

PLAN LEGEND SHEET

SUMMARY TABLE OF QUANTITIES

TYPICAL SECTIONS

EXISTING CONDITIONS

DEMOLITION PLAN

SITE LAYOUT & PAVEMENT PLAN

GEOMETRIC CONTROL LAYOUT

UTILITY PLAN

GRADING & DRAINAGE PLAN

STORM NETWORK PROFILES

CIVIL CONSTRUCTION DETAILS

EROSION CONTROL PLAN

EROSION CONTROL DETAILS

TRAFFIC CONTROL PLAN

LANDSCAPE PLANS

LP100

LP200

LP201

SV

AC202

LP202

LP500

LI100

LI200

LI201

LI202

LI500

LI501

LS100

LS101

ELECTRICAL

E100 E101 E102 E103 E200

PLANTING PLAN

PLANTING PLAN ENLARGEMENT

PLANTING PLAN ENLARGEMENT

TOPOGRAPHIC SURVEY

ANTICIPATED CONDITIONS PLAN

PLANTING PLAN ENLARGEMENT

PLANTING DETAILS

IRRIGATION PLAN

IRRIGATION PLAN ENLARGEMENT

IRRIGATION PLAN ENLARGEMENT

IRRIGATION PLAN ENLARGEMENT

IRRIGATION DETAILS

IRRIGATION DETAILS

SPECIFICATIONS

SPECIFICATIONS

OVERALL SITE PLAN

ENLARGED ELECTRICAL PLAN

ENLARGED ELECTRICAL PLAN

ENLARGED ELECTRICAL PLAN

ELECTRICAL PANEL SCHEDULES & DETAILS

CI

VI

L

CO

NS

TR

UC

TI

ON

N

OT

ES

EA

ST

ND

S

TR

EE

T

IM

PR

OV

EM

EN

TS

CI

TY

O F

GU

LF

S

HO

RE

S

JOB NO:

SCALE:

DATE:

DRAFTER:

SHEET:

25-1998.20

JULY 2026

TLE/BLS/PWM

G re en o R d N o rt h S te

C

F ai rh o p e, A la b am a

P .O

B o x

F ai rh o p e, A la b am a

P h o n e:

-3 ja d en gi n ee rs .c o m

A

L

C A

-3 -E

AP

PR

DA

TE

RE

VI

SI

ON

NO

/2

0/

IS

SU

E

FO

R

BI

D

1.

1. THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL STATE, LOCAL AND FEDERAL

LAWS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT ALL OF THESE LAWS AND

REGULATIONS HAVE BEEN MET.

2. THE CONTRACTOR SHALL NOTIFY JADE CONSULTING'S RESPECTIVE TESTING COMPANY AND ANY

LOCAL JURISDICTIONAL INSPECTOR FOR APPROVAL 48 HOURS BEFORE THE BEGINNING OF ANY

SUBSEQUENT PHASE OF CONSTRUCTION.

3. THE CONTRACTOR SHALL IMMEDIATELY INFORM THE ENGINEER OF ANY DISCREPANCIES OR

ERRORS DISCOVERED IN THE PLANS.

4. THE CONTRACTOR IS REQUIRED TO COORDINATE WITH THE ONE-CALL LINE LOCATE CENTER FOR

THE MARKING OF UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL

RENEW CONFORMATION NUMBERS AS OFTEN AS REQUIRED DURING THE DURATION OF THE

PROJECT. THE CURRENT CONFIRMATION NUMBER SHALL BE ON PROJECT SITES AT ALL TIMES.

5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE LOCATION OF ANY AND ALL

EXISTING UNDERGROUND UTILITIES AND TO TAKE WHATEVER STEPS ARE NECESSARY TO

PROVIDE FOR THEIR PROTECTION. THE ENGINEER HAS DILIGENTLY ATTEMPTED TO LOCATE AND INDICATE ALL EXISTING FACILITIES ON THESE PLANS. HOWEVER, THIS INFORMATION IS SHOWN

FOR THE CONTRACTORS CONVENIENCE ONLY. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR

THE LOCATION OF UTILITIES SHOWN OR NOT SHOWN. THE CONTRACTOR SHALL CONTACT THE

UTILITY COMPANIES FOR EXACT LOCATION OF THEIR UTILITIES PRIOR TO STARTING

CONSTRUCTION. ANY AND ALL DAMAGE MADE TO UTILITIES BY THE CONTRACTOR SHALL BE THE

SOLE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR AND REPLACE.

6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING INFRASTRUCTURE.

7. ALL WATER CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO THE LATEST

EDITION OF THE "STANDARDS AND SPECIFICATIONS" OF GULF SHORES UTILITIES.

8. ALL SEWER CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO THE LATEST

EDITION OF THE "STANDARDS AND SPECIFICATIONS" OF GULF SHORES UTILITIES.

9. ALL MANHOLES WITHIN THE 100 YEAR FLOOD PLAIN SHALL BE CONSTRUCTED THREE (3) FEET

ABOVE GRADE.

10. THE CONTRACTOR SHALL EMPLOY ALL NECESSARY MEASURES TO ENSURE THAT THE PROJECT IS

OSHA COMPLIANT.

11. THE CONTRACTOR SHALL EXPLORE EXISTING STRUCTURES, UTILITIES AND PIPING SO THAT ANY

REQUIRED ADJUSTMENT MAY BE MADE.

12. ANY EXCESS MATERIAL FROM CONSTRUCTION ACTIVITIES SHALL BE LEGALLY DISPOSED OF BY

THE CONTRACTOR AT HIS EXPENSE.

13. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE LOCATION AND INVERTS OF ALL

UTILITIES PRIOR TO COMMENCEMENT OF ANY WORK ITEM. THE PROJECT ENGINEER SHALL BE

NOTIFIED IMMEDIATELY IF ANY DISCREPANCIES ARE FOUND.

14. CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION WITH ALL RESPECTIVE UTILITY

PROVIDERS AND AUTHORITIES. PROPER NOTICE SHALL BE GIVEN PRIOR TO ANY WORK STARTING.

15. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ADEQUATE BEDDING AND HAUNCHING FOR ALL

IMPROVEMENTS.

16. CONTRACTOR SHALL REPLACE ANY FAULTY OR IMPROPERLY INSTALLED IMPROVEMENTS AT THEIR

EXPENSE.

17. THE CONTRACTOR SHALL EMPLOY A LAND SURVEYOR REGISTERED IN THE STATE OF ALABAMA TO

RESET ANY PROPERTY MARKERS DAMAGED DURING CONSTRUCTION AT THE CONTRACTOR'S

EXPENSE.

18. CONTRACTOR SHALL NOT DEVIATE FROM PLANS WITHOUT WRITTEN CONSENT.

19. OMIT.

20. CONTRACTOR SHALL STRICTLY FOLLOW THE LOCAL AUTHORITIES AND/OR GEOTECHNICAL

REPORTS FOR ALL GRADING, BACKFILLING, AND PAVING REQUIREMENTS. ALL RESPECTIVE TASKS

SHALL BE APPROVED BY RESPONSIBLE INSPECTOR PRIOR TO ACCEPTANCE.

21. THE CONTRACTOR WILL ENSURE THAT POSITIVE AND ADEQUATE DRAINAGE IS MAINTAINED AT

ALL TIMES WITHIN THE PROJECT LIMITS. THIS MAY INCLUDE, BUT NOT BE LIMITED TO,

REPLACEMENT OR RECONSTRUCTION OF EXISTING DRAINAGE STRUCTURES THAT HAVE BEEN

DAMAGED, REMOVED OR REGRADED AS REQUIRED BY THE ENGINEER.

22. ALL GRAVITY PIPES SHALL BE LAID ON SMOOTH CONTINUOUS GRADES WITH NO DETECTABLE

BENDS AT JOINTS.

23. ALL STORM DRAINAGE INLET STRUCTURES SHALL HAVE A NEENAH CAST IRON FRAME AND COVER, OR APPROVED EQUAL, FOR ACCESS.

24. SOIL TESTING AND ON-SITE INSPECTION SHALL BE PERFORMED BY AN INDEPENDENT

GEOTECHNICAL ENGINEER. THE SOILS ENGINEER SHALL PROVIDE COPIES OF TEST REPORTS TO

THE CONTRACTOR, THE OWNER AND THE OWNER'S REPRESENTATIVE AND SHALL PROMPTLY

NOTIFY THE OWNER, HIS REPRESENTATIVE AND THE CONTRACTOR SHOULD WORK PERFORMED

BY THE CONTRACTOR FAIL TO MEET THESE SPECIFICATIONS. THE CONTRACTOR SHALL PROVIDE

ADEQUATE NOTICE TO SOILS ENGINEER FOR THE REQUIRED TESTING OF THE PROJECT.

25. THE CONTRACTOR SHALL PROVIDE ANY EXCAVATION AND MATERIAL SAMPLES NECESSARY TO

CONDUCT REQUIRED SOIL TESTS. ALL ARRANGEMENTS AND SCHEDULING FOR THE TESTING

SHALL BE THE CONTRACTORS RESPONSIBILITY.

SITE NOTES:

PROJECT NOTES:

1. ALL TRAFFIC CONTROL SHALL COMPLY WITH THE LATEST EDITION OF THE MANUAL ON

UNIFORM TRAFFIC CONTROL DEVICES (MUTCD).

2. ALL TRAFFIC PLANS SHALL BE COORDINATED WITH THE CITY OF GULF SHORES PUBLIC WORKS

DEPARTMENT.

3. NECESSARY BARRICADES, SUFFICIENT LIGHTS, SIGNS AND OTHER TRAFFIC CONTROL

METHODS MAY BE NECESSARY AS PER THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES,

PART IV. THESE DEVICES SHALL BE PROVIDED AND MAINTAINED THROUGHOUT

CONSTRUCTION. NO SEPARATE PAYMENT WILL BE MADE FOR TRAFFIC CONTROL

REQUIREMENTS.

4. ALL TEMPORARY TRAFFIC CONTROL SHALL COMPLY WITH PART VI OF THE MUTCD LATEST

EDITION.

5. ROAD CLOSURES SHALL NOT BEGIN UNTIL SEPTEMBER 8, 2026

TRAFFIC CONTROL NOTES:

1. ALL EROSION CONTROL PROCEDURES SHALL BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH THE

"ALABAMA HANDBOOK FOR EROSION CONTROL AND STORMWATER MANAGEMENT ON CONSTRUCTION

SITES AND URBAN AREAS".

2. ALL BEST MANAGEMENT PRACTICES (BMP) PROCEDURES SHALL BE IN PLACE AND INSPECTED PRIOR TO ANY

LAND DISTURBING ACTIVITY.

3. ALL DISTURBED AREAS SHALL BE TEMPORARILY GRASSED AND MULCHED IF THEY WILL BE LEFT

UNATTENDED FOR 13 DAYS.

4. ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED BY THE PROJECT ENGINEER AND/OR LOCAL

JURISDICTIONAL INSPECTOR.

5. CONSTRUCTION ENTRANCE/EXIT PADS SHALL BE INSTALLED BY THE CONTRACTOR AT CONSTRUCTION ACCESS POINTS PRIOR TO LAND DISTURBANCE AND SHALL BE MAINTAINED THROUGHOUT THE PROJECT.

(NO DIRECT PAYMENT)

6. THE APPROVED BEST MANAGEMENT PRACTICES PLAN SHALL BE PRESENT ON THE SITE WHENEVER LAND

DISTURBING ACTIVITY HAS BEGUN.

7. SILT FENCE AND/OR EROSION CONTROL NETTING SHALL BE PLACED ALONG THE DOWNSTREAM SIDE OF

ALL PROPOSED FILL CONSTRUCTION.

8. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ACCOMPLISH EROSION CONTROL FOR ALL DRAINAGE

PATTERNS CREATED AT VARIOUS STAGES DURING CONSTRUCTION.

9. WHEN REQUIRED CONTRACTOR SHALL INSPECT EROSION CONTROL MEASURES AT THE END OF EACH WORKING DAY AND RAIN EVENT TO ENSURE MEASURES ARE FUNCTIONING PROPERLY. CONTRACTOR SHALL

PROPERLY MAINTAIN ALL BMP'S IN ACCORDANCE WITH THE "HANDBOOK".

10. CONTRACTOR SHALL IMMEDIATELY REPAIR AND/OR REPLACE ANY DAMAGED OR IMPROPERLY FUNCTIONING

BMP.

11. ANY SILT IN THE DETENTION POND SHALL BE REMOVED AS DIRECTED BY THE PROJECT ENGINEER OR LOCAL AUTHORITY. THE DETENTION POND SHALL ALSO BE REGRADED TO FINAL DESIGN PRIOR TO FINAL

ACCEPTANCE OF PROJECT. THERE IS NO DIRECT PAYMENT FOR THIS ACTIVITY.

12. ALL DISTURBED AREAS MUST BE PERMANENTLY STABILIZED IN ACCORDANCE WITH THE HANDBOOK PRIOR

TO FINAL ACCEPTANCE.

13. CONTRACTOR SHALL ROUTINELY CLEAN OUT ANY SILT ACCUMULATION FROM THE PROJECTS DRAINAGE

STRUCTURES AS REQUIRED BY PROJECT ENGINEER AND/OR LOCAL AUTHORITY.

14. CONTRACTOR IS SOLELY RESPONSIBLE FOR SEDIMENT CONTROL AND STORMWATER MANAGEMENT FOR PROJECT. CONTRACTOR SHALL NOTIFY PROJECT ENGINEER IMMEDIATELY OF ANY FAILING BMP.

SEDIMENT CONTROL & STORMWATER MANAGEMENT NOTES:

PHASE ONE

· INSTALL CONSTRUCTION ENTRANCE/EXIT

· CLEAR AREA REQUIRED FOR SILT FENCE PLACEMENT

· INSTALL SILT FENCE (SBA)

PHASE TWO

· WATTLES, INLET, AND OUTLET PROTECTION TO BE INSTALLED

PHASE THREE

· DEMOLITION AND REMOVAL OF DEMO DEBRIS

· CLEAR/GRUB REMAINING SITE AREAS

PHASE FOUR

· INSTALL STORM DRAINAGE MEASURES

· GRADE SITE TO ROUGH GRADES

PHASE FIVE

· CONSTRUCT ROADS (PAVING, CURB AND GUTTER, SIDEWALKS, AND DRIVEWAYS)

PHASE SIX

· STABILIZE DISTURBED AREAS WITH SOLID SOD

· INSTALL PERMANENT LANDSCAPING

PHASE SEVEN

· REMOVE BMP MEASURES

· REMOVE SILT FENCE

· PROJECT COMPLETE, FINAL INSPECTION, FILE NOTICE OF TERMINATION

CONSTRUCTION PHASE SEQUENCE:

C2

N/A

PARKING STRIPING NOTE:

PARKING STRIPES ON CONCRETE SHOULD ALWAYS BE YELLOW AND PARKING STRIPES ON

ASPHALT SHOULD ALWAYS BE WHITE UNLESS OTHERWISE SPECIFIED IN THE CONSTRUCTION

DOCUMENTS.

1. TREES FOR REMOVAL ARE MARKED WITH A DEMOLITION "X".

2. CLEAR AND GRUB ALL AREAS WITHIN POND AND ROADWAY FOOTPRINTS.

3. ALL DEMOLITION TO BE DISPOSED OF IN ACCORDANCE WITH ALL LOCAL, STATE, AND

FEDERAL LAWS AND REGULATIONS.

DEMOLITION NOTE:

PL

AN

L

EG

EN

D

SH

EE

T

EA

ST

ND

S

TR

EE

T

IM

PR

OV

EM

EN

TS

CI

TY

O

F

GU

LF

S

HO

RE

S

JOB NO:

SCALE:

DATE:

DRAFTER:

SHEET:

25-1998.20

JULY 2026

TLE/BLS/PWM

G re en o R d N o rt h S te

C

F ai rh o p e, A la b am a

P .O

B o x

F ai rh o p e, A la b am a

P h o n e:

-3 ja d en gi n ee rs .c o m

A

L

C A

-3 -E

AP

PR

DA

TE

RE

VI

SI

ON

NO

/2

0/

IS

SU

E

FO

R

BI

D

1.

C3

N/A

PROPOSED 24" BY 24" GRATE INLET

PROPOSED ALDOT TYPE PD STORM INLET

C

FO

FO

G

W

WV

E

W

C

C

UP

C

E

CO

W

PROPOSED SIGNAGE

S

G

PROPOSED TYPE R NEEDNAH CURB INLET

PROPOSED JUNCTION BOX

LEGEND

BENCHMARK

EXISTING AXLE FOUND

CONCRETE MONUMENT FOUND

OPEN TOP IRON PIPE FOUND

CAPPED ROD FOUND

CAPPED ROD SET

160.50 T.O.C.

160.00

R.O.W.

FO FO FO FO

EXIST. RIGHT-OF-WAY

CENTERLINE EXIST. CENTERLINE

EXIST. PROPERTY LINE (ADJACENT)

EXIST. OVERHEAD UTILITY AND UTILITY POLE

EXIST. GUY WIRE AND UTILITY POLEGUY

EXIST. WATER LINE

EXIST. SANITARY SEWER LINE

EXIST. GAS LINE

EXIST. OVERHEAD COMMUNICATION

EXIST. FIBER OPTIC CABLE LINE

EXIST. FENCE LINE

EXIST. PIPE

PROPOSED CONCRETE JOINTS

EXIST. POWER POLE

EXIST. LIGHT POLE

EXIST. ELECTRICAL BOX

EXIST. WATER METER

EXIST. WATER VALVE

EXIST. 1 FOOT CONTOUR

EXIST. 5 FOOT CONTOUR

EXIST. GRADE SPOT ELEVATION

PROPOSED 1 FOOT CONTOUR

PROPOSED 5 FOOT CONTOUR

FINISHED GRADE ELEVATION (TOP OF CURB)

FINISHED GRADE ELEVATION

EXIST. PROPERTY LINE

TO BE REMOVED

TO BE REMOVED

PROPOSED RIGHT-OF-WAY

PROPOSED CENTERLINE

EXIST. UNDER GROUND COMMUNICATION

PROPOSED 0.5 FOOT CONTOUR

EXIST. RETAINING WALL

EXIST. LANDSCAPE

EXIST. BULKHEAD

EXIST. EDGE OF WATER

EXISTING SIGNAGE

EXIST. WATER METER

EXIST. WATER METER

EXIST. FIRE HYDRANT

EXIST. ELECTRICAL METER

EXIST. ELECTRICAL BOX

EXIST. UTILITY POLE

EXIST. ELECTRICAL BOX

EXIST. MAILBOX

EXIST. NATURAL GAS MARKER

EXIST. NATURAL GAS REGULATOR

EXIST. COMMUNICATION VAULT

EXIST. COMMUNICATION

EXIST. COMMUNICATION BOX

EXIST. COMMUNICATION

EXIST. FIBER OPTICS MARKER

EXIST. FIBER OPTICS MARKER

EXIST. SANITARY SEWER MANHOLE

EXIST. SANITARY SEWER CLEANOUT

EXIST. STORM INLET

EXIST. STORM INLET

EXISTING OAK

EXISTING PALM

EXISTING PINE

EXISTING LIVE OAK

TREE LEGEND

PROPOSED STRIPES

ASPHALT TO BE MILLED

EXIST. ASPHALT PAVING

EXIST. CONCRETE

EXIST. GRAVEL

PROPOSED HEAVY DUTY ASPHALT

PROPOSED CONCRETE (BROOM FINISH)

PROPOSED HEAVY DUTY

CONCRETE (BROOM FINISH)

PROPOSED SOLID SOD/SEED AND MULCH

PROPOSED PAVERS

PROPOSED ASPHALT PAVEMENT PATCH

PROPOSED ASPHALT OVERLAY

PROPOSED LIGHT DUTY ASPHALT

EXIST. UNDERGROUND ENERGYUGE UGE UGE UGE

PROPOSED 0.5 FOOT CONTOUR

PROPOSED AGGREGATE SURFACE (MATCH EX. CONDITIONS)

SU

M

M

AR

Y

TA

BL

E

OF

Q

UA

NT

IT

IE

S

EA

ST

ND

S

TR

EE

T

IM

PR

OV

EM

EN

TS

CI

TY

O

F

GU

LF

S

HO

RE

S

JOB NO:

SCALE:

DATE:

DRAFTER:

SHEET:

25-1998.20

JULY 2026

TLE/BLS/PWM

G re en o R d N o rt h S te

C

F ai rh o p e, A la b am a

P .O

B o x

F ai rh o p e, A la b am a

P h o n e:

-3 ja d en gi n ee rs .c o m

A

L

C A

-3 -E

AP

PR

DA

TE

RE

VI

SI

ON

NO

/2

0/

IS

SU

E

FO

R

BI

D

1.

C4

N/A

QUANTITY ALDOT

ITEM NO. UNIT ITEM DESCRIPTION PROJECT NOTES

1 201-A LS CLEARING AND GRUBBING

330 206-C SY REMOVING CONCRETE SIDEWALK

3510 206-C SY REMOVING ASPHALT PAVEMENT

420 206-D LF REMOVING PIPE

90 206-D LF REMOVING UTILITY LINES

3 206-E EA REMOVING HEADWALLS

3 206-E EA REMOVING INLET

3 209-A EA MAILBOX RESET, MULTIPLE

1200 210-A CUYD UNCLASSIFIED EXCAVATION

900 210-D CUYD BORROW EXCAVATION

40 214-B CUYD FOUNDATION BACKFILL

60 214-B CUYD FOUNDATION BACKFILL, COMMERCIAL (#57 STONE) 4"TO 6" THICK

4525 230-B SQYD ROADBED PROCESSING

18 262-B CUYD PORTLAND CEMENT PRESSURE GROUT

4025 301-A SQYD CRUSHED AGGREGATE BASE COURSE, TYPE B, PLANT MIXED, 6" COMPACTED THICKNESS

3204 401-A SQYD BITUMINOUS TREATMENT A

3856 405-A SQYD TACK COAT (0.05 GAL/SY)

660 408-A SQYD PLANING EXISTING PAVEMENT (APPROXIMATELY 0" THRU 3.0" THICK)

3856 424-A SQYD SUPERPAVE BITUMINOUS CONCRETE WEARING SURFACE LAYER, 1/2" MAXIMUM

AGGREGATE SIZE MIX, ESAL RANGE C/D, 165 LB/SY

3204 424-B SQYD SUPERPAVE BITUMINOUS CONCRETE UPPER BINDER LAYER, 1" MAXIMUM AGGREGATE SIZE

MIX, ESAL RANGE C/D, 250 LB/SY

2192 424-B SQYD SUPERPAVE BITUMINOUS CONCRETE LOWER BINDER LAYER, 1" MAXIMUM AGGREGATE

SIZE MIX, ESAL RANGE C/D, 250 LB/SY

6 430-B TONS AGGREGATE SURFACING

222 533-A LF 18" STORM SEWER PIPE (CLASS 3 R.C.)

370 533-A LF 24" STORM SEWER PIPE (CLASS 3 R.C.)

808 533-A LF 30" STORM SEWER PIPE (CLASS 3 R.C.)

35 533-B LF 18" SPAN, 11" RISE STORM SEWER PIPE (CLASS 3 R.C.)

172 533-B LF 22" SPAN, 14" RISE STORM SEWER PIPE (CLASS 3 R.C.)

1 600-A LS MOBILIZATION

425 613-F SQYD PAVER FIELDS, PEDSETRIAN DUTY WITH STONE BASE

1150 618-A SQYD CONCRETE SIDEWALK, 6" THICK

175 618-B SQYD CONCRETE DRIVEWAY, 6" THICK (INCLUDES WIRE MESH)

210 618-C SQFT DETECTABLE WARNING SURFACE

17 618-D EA CURB RAMP

3 621-A EA JUNCTION BOX, TYPE 1P

2 621-A EA JUNCTION BOX, TYPE SPECIAL

3 621-C EA INLET, CURB AND GUTTER (NEENAH CURB INLET, MODEL R-3067 TYPE -R)

3 621-C EA INLET, CURB AND GUTTER (NEENAH CURB INLET, MODEL R-3067 TYPE -R) SPECIAL BOX

3 621-C EA INLETS, TYPE PD

10 621-C EA INLET GRATES, TYPE B, 24"x24"

3 622-A EA MANHOLE COVER RESET

810 623-B LF 12" FLUSH RIBBON CURB

835 623-B LF 6" CONCRETE HEADER CURB

1290 623-C LF CONCRETE CURB & GUTTER, TYPE M-2

15 641-A LF 6" P.V.C WATER MAIN LAID, C900

679 641-A LF 12" P.V.C WATER MAIN LAID, C900

4 641-C EA 6" 45° BEND

1 641-C EA 12" X 6" TEE FITTING

3 641-C EA 12" TEE FITTINGS

2 641-C EA 12" X 6" REDUCER FITTINGS

2 641-C EA 12" 45° BEND FITTINGS

1 641-C EA 12" PLUG

1 641-J EA 6" INSERTA VALVE (TEAM VALVE INSERTION)

1 641-J EA 12" INSERTA VALVE (TEAM VALVE INSERTION)

1 641-J EA 6" GATE VALVE W/ BOX

5 641-J EA 12" GATE VALVE W/ BOX

5 641-K CY CONCRETE FOR WATER MAINS (THRUST BLOCKS)

1 641-O EA 12" X 12" TAPPING VALVE AND SLEEVE

1 LS WATER MAIN BAC-T AND PRESSURE TESTS

34 663-C LF TREE PROTECTION FENCING

1105 665-J LF SILT FENCE, TYPE "A"

1105 665-O LF SILT FENCE REMOVAL

21 665-P EA INLET PROTECTION, STAGE 3 OR 4

1 680-A LS ENGINEERING CONTROLS

1135 701-G LF SOLID WHITE, CLASS 2 TYPE A TRAFFIC STRIPES

105 701-G LF SOLID YELLOW, CLASS 2 TYPE A TRAFFIC STRIPES (701-G)

220 703-A SQFT TRAFFIC CONTROL MARKINGS, CLASS 2 TYPE A (703-A)

100 703-B SQFT TRAFFIC CONTROL LEGENDS, THERMOPLASTIC "GOLF CART ONLY" W/ STENCIL (703-B)

1 740-A LS TRAFFIC CONTROL SCHEME (740-A)

1 710-C LS REMOVAL OF EXISTING ROADWAY SIGNS

1 711-A LS ROADWAY SIGN RELOCATION

1 LS UNDERGROUND UTILITY ADJUSTMENT (GAS)

1 LS UNDERGROUND UTILITY ADJUSTMENT (ELECTRICAL)

1 LS UNDERGROUND UTILITY ADJUSTMENT (COMMUNICATION)

1 LS LANDSCAPE ITEMS

SUMMARY TABLE OF QUANTITIES

ALTERNATE BID (E 22ND AVE):

QUANTITY ALDOT

ITEM NO. UNIT ITEM DESCRIPTION PROJECT NOTES

1 201-A LS CLEARING AND GRUBBING

75 206-C SY REMOVING CONCRETE SIDEWALK

54 206-C SY REMOVING CONCRETE DRIVEWAY

270 206-C SY REMOVING ASPHALT PAVEMENT

218 206-D LF REMOVING FENCE

17 206-D LF REMOVING PIPE

4 206-E EA REMOVING TREES

200 210-A CUYD UNCLASSIFIED EXCAVATION

100 210-D CUYD BORROW EXCAVATION

10 214-B CUYD FOUNDATION BACKFILL

10 214-B CUYD FOUNDATION BACKFILL, COMMERCIAL (#57 STONE) 4"TO 6" THICK (214-B)

375 230-B SQYD ROADBED PROCESSING

326 301-A SQYD CRUSHED AGGREGATE BASE COURSE, TYPE B, PLANT MIXED, 6" COMPACTED THICKNESS

250 401-A SQYD BITUMINOUS TREATMENT A

725 405-A SQYD TACK COAT (0.05 GAL/SY)

480 408-A SQYD PLANING EXISTING PAVEMENT (APPROXIMATELY 0" THRU 3.0" THICK)

725 424-A SQYD SUPERPAVE BITUMINOUS CONCRETE WEARING SURFACE LAYER, 1/2" MAXIMUM

AGGREGATE SIZE MIX, ESAL RANGE C/D, 165 LB/SY

250 424-B SQYD SUPERPAVE BITUMINOUS CONCRETE UPPER BINDER LAYER, 1" MAXIMUM AGGREGATE SIZE

MIX, ESAL RANGE C/D, 250 LB/SY

183 533-A LF 18" STORM SEWER PIPE (CLASS 3 R.C.)

1 600-A LS MOBILIZATION

60 613-F SQYD PAVER FIELDS, PEDSETRIAN DUTY WITH STONE BASE

180 618-A SQYD CONCRETE SIDEWALK, 6" THICK

70 618-B SQYD CONCRETE DRIVEWAY, 6" THICK (INCLUDES WIRE MESH)

2 621-C EA INLET, CURB AND GUTTER (NEENAH CURB INLET, MODEL R-3067 TYPE -R)

2 621-C EA INLETS, TYPE PD

72 623-B LF 12" FLUSH RIBBON CURB

290 623-C LF CONCRETE CURB & GUTTER, TYPE M-2

215 665-J LF SILT FENCE, TYPE "A"

215 665-O LF SILT FENCE REMOVAL

4 665-P EA INLET PROTECTION, STAGE 3 OR 4

1 680-A LS ENGINEERING CONTROLS

590 701-G LF SOLID WHITE, CLASS 2 TYPE A TRAFFIC STRIPES

385 701-G LF SOLID YELLOW, CLASS 2 TYPE A TRAFFIC STRIPES (701-G)

1 740-A LS TRAFFIC CONTROL SCHEME (740-A)

1 LS SIGNAGE ITEMS

1 LS LANDSCAPE ITEMS

N.T.S

TY

PI

CA

L

SE

CT

IO

N

EA

ST

ND

S

TR

EE

T

IM

PR

OV

EM

EN

TS

CI

TY

O F

GU

LF

S

HO

RE

S

JOB NO:

SCALE:

DATE:

DRAFTER:

SHEET:

25-1998.20

JULY 2026

TLE/BLS/PWM

G re en o R d N o rt h S te

C

F ai rh o p e, A la b am a

P .O

B o x

F ai rh o p e, A la b am a

P h o n e:

-3 ja d en gi n ee rs .c o m

A

L

C A

-3 -E

AP

PR

DA

TE

RE

VI

SI

ON

NO

/2

0/

IS

SU

E

FO

R

BI

D

1.

C5

TYPICAL ROADWAY SECTION

EAST 2ND STREET (SECTION B) (GULF PINES)

ROW VARIES (~130')

3 1111

10 91

TYPICAL ROADWAY SECTION

EAST 2ND STREET (SECTION A) (GULF PINES)

ROW VARIES (~130')

1. THE FULL WIDTH OF THE TYPICAL SECTION, FROM TIE POINT TO TIE

POINT, SHALL BE GRADED AND PERMANENTLY STABILIZED PRIOR TO FINAL

INSPECTION WITH CITY OF GULF SHORES.

2. SOLID SOD SHALL BE PROVIDED BETWEEN SIDEWALK AND BACK OF CURB.

3. EXPANSION JOINT MATERIAL SHALL BE PROVIDED AT ALL RADII POINTS

ALONG THE CONCRETE CURB & GUTTER AND SIDEWALKS AND WHERE CURB

AND SIDEWALKS ADJOIN CURB INLETS.

TYPICAL SECTION NOTES:

TYPICAL ROADWAY ALT #1 SECTION

EAST 22ND AVE (SECTION B) (GULF PINES)

ROW VARIES (~80')

6 1413

9 1111 1 7

3 3 2

8 8

8 810

ALL GRADING AND PAVING SHALL CONFORM WITH

GEOTECH REPORT ORIGINAL REPORT PROVIDED BY

"GEOTECHNICAL ENGINEERING TESTING, INC."

DATED APRIL 3, 2026.

ALSO GEOTECH ADDENDUM REPORT PROVIDED BY

"GEOTECHNICAL ENGINEERING TESTING, INC."

DATED JUNE 11, 2026.

P X

W

C C

C E W

C

C

E

TR

TR

TR

C

C

C

C

C

C C

C

C C

C

C C

C

C

C

C

C

C C

C

C C C C

C

C

C

C C

E

E

S

C

C

E E

E

E

E

EEE

E E

TR

W

W

W

W V W V

E

E

C S

S

UGE

UGE

E E

W W

C O

TR

UGE UGE UGE UGE UGE

UGE UGE UGE UGE UGE UGE UGE UGE UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UGE UGE UGE UGE UGE UGE

UG

E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U G

E U

G E

UGE

UGE

UGE

UGE

UGE

UGE

UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE UGE UGE UGE UGE UGE

UGE UGE UGE UGE UGE UGE

UGE UGE UGE UGE UGE UGE UGE

UGE

UGE

UGEUGE

UGE

UGEUGEUGEUGEUGE

U G

E U

G E

UGE

UGE

UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

U G

E U

G E

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

U G

E U

G E

U G

E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E

UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE

UGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGE

UGE

UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E

UGE UGE UGE UGE UGE UGE UGE

UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE

UGE

UGE

S

VAN

C

C

W V

EX

IS

TI

NG

C

ON

DI

TI

ON

S

C6

EA

ST

ND

S

TR

EE

T

IM

PR

OV

EM

EN

TS

CI

TY

O F

GU

LF

S

HO

RE

S

JOB NO:

SCALE:

DATE:

DRAFTER:

SHEET:

25-1998.20

JULY 2026

TLE/BLS/PWM

G re en o R d N o rt h S te

C

F ai rh o p e, A la b am a

P .O

B o x

F ai rh o p e, A la b am a

P h o n e:

-3 ja d en gi n ee rs .c o m

A

L

C A

-3 -E

AP

PR

DA

TE

RE

VI

SI

ON

NO

/2

0/

IS

SU

E

FO

R

BI

D

1.

1" = 20'

TBM #1

ELEV = 9.95

TBM #2

ELEV = 9.53

BENCHMARK INFORMATION:

UTILITY INFORMATION

CONTRACTOR SHALL HAVE ALL EXISTING BURIED UTILITIES

"LINE SPOTTED" BY CALLING 1-800-292-8925 (ALABAMA ONE-CALL)

OR BY CONTACTING LOCAL UTILITY COMPANIES

WATER/ SEWER:

GULF SHORES UTILITIES

RHONDA BUTLER - GENERAL MANAGER

(251) 968-6323 ext 3336 gsurbutler@gmail.com

1629 EAST 1ST ST, GULF SHORES, AL 36542

POWER:

BALDWIN EMC

KEN PIMPERL - (251) 989-0220

19600 STATE HIGHWAY 59, SUMMERDALE, AL 36580

GAS:

RIVIERA UTILITIES

JAMES WALLACE - (251) 943-5001

413 EAST LAUREL AVE, FOLEY, AL 36535

FIBER/ OTHER

COMMUNICATION:

BRIGHTSPEED

FORREST CHERNEY - (980) 376-1408

1120 SOUTH TRYON ST, SUITE 700, CHARLOTTE, NC 28203

Professional Land Surveyors

SURVEY PROVIDED BY:

Wattier Surveying, Inc.

( IN FEET )

1 inch = ft.

GRAPHIC SCALE

1. REFER TO SHEET C2 FOR ADDITIONAL NOTES.

2. REFER TO SHEET C3 FOR LEGEND.

GENERAL NOTES:

EXISTING UTILITIES INDICATED ON THESE PLANS ARE BASED ON

AVAILABLE INFORMATION. CONTRACTOR IS REQUIRED TO VERIFY

LOCATION, BURY DEPTH, SIZE AND MATERIAL TYPE PRIOR TO ANY

UTILITY IMPROVEMENTS. THE ENGINEER SHALL BE NOTIFIED

IMMEDIATELY OF ANY DISCREPANCIES THAT ARE FOUND.

EXISTING UTILITIES DISCLAIMER:

P X

W

C C

C E W

C

C

E

TR

TR

TR

C

C

C

C

C

C

C

C C

C

C C

C

C

C

C

C

C C

C

C C C C

C

C

C

C C

E

E

S

C

C

E E

E

E

E

EEE

E E

TR

W

W

W

W V W V

E

E

C S

S

UGE

UGE

E E

W W

C O

TR

UGE UGE UGE UGE UGE

UGE UGE UGE UGE UGE UGE UGE UGE UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UGE UGE UGE UGE UGE UGE

UG

E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U G

E U

G E

UGE

UGE

UGE

UGE

UGE

UGE

UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE UGE UGE UGE UGE UGE

UGE UGE UGE UGE UGE UGE

UGE UGE UGE UGE UGE UGE UGE

UGE

UGE

UGEUGE

UGE

UGEUGEUGEUGEUGE

U G

E U

G E

UGE

UGE

UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

U G

E U

G E

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

U G

E U

G E

U G

E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E

UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE

UGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGE

UGE

UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E

UGE UGE UGE UGE UGE UGE UGE

UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE

UGE

UGE

S

VAN

AL

T

AL

T

1BASE BID

C

C

W V

REQD., REMOVE APPROX. 10LF OF ABANDONED 12" WATER LINE

FOR STORM DRAINAGE INSTALLATION EFFORTS

(PROPER DISPOSAL OF ASBESTOS-CEMENT PIPE REQUIRED)

REQD., MILL EXIST. ASPHALT W/IN

HATCHED AREA, 1.25" MIN. THICKNESS

(REMOVE)

REQD., REMOVE EXISTING ASPHALT DRIVE.

(SAWCUT TO PROVIDE SMOOTH EDGE)

REQD., SAWCUT AND REMOVE EXISTING CONCRETE SIDEWALK

(SAWCUT TO PROVIDE SMOOTH EDGE)

REQD., REMOVE / RELOCATE EXISTING TRAFFIC SIGNAL POLE AND

GUY WIRE (COORDINATE WITH LOCAL UTILITY COMPANY)

REQD., REMOVE EXISTING STORM STRUCTURES

REQD., REMOVE EXISTING CONCRETE SIDEWALK

(TO REMAIN)

REQD., TO REMOVE

REQD., REMOVE EXISTING GRATE INLET

REQD., REMOVE EXISTING CONCRETE SIDEWALK

REQD., REMOVE

REQD., REMOVE EXISTING WOOD BARRIER

REQD., REMOVE EXISTING LIGHT POLE

REQD., REMOVE EXISTING LIGHT POLE

REQD, REMOVE / RESET

EXISTING MAILBOXES

SEE UTILITY NOTE 1.

SEE UTILITY NOTE 1.

(REMAIN)

REQD., TO REMOVE

REQD., REMOVE EX. TREES

SEE UTILITY NOTE 1.

REQD, REMOVE 218 LF OF

EXISTING FENCE

SEE UTILITY NOTE 1.

SEE UTILITY NOTE 1.

SEE UTILITY NOTE 1.

REQD., REMOVE EXISTING SIGN

REQD., REMOVE EXISTING SIGN, SAVE AND RELOCATE

(COORD. WITH CITY FOR RELOCATION EFFORTS)

REQD., REMOVE

REQD., ADJUST RING & COVER FLUSH W/ SIDEWALK

REQD., ADJUST RING & COVER FLUSH

REQD., EXISTING SANITARY SEWER MANHOLE

RING AND COVER TO BE RESET

REQD., MILL EXIST. ASPHALT W/IN HATCHED AREA, 1.5" MIN. THICKNESS

REQD., MILL EXIST. ASPHALT W/IN HATCHED AREA, 1.25" MIN. THICKNESS

REQD., MILL EXIST. ASPHALT W/IN

HATCHED AREA, 1.25" MIN. THICKNESS

(REMAIN)

REQD., ADJUST RING & COVER

(RESET FLUSH W/ SIDEWALK)

(TO REMAIN)

(TO REMAIN)

REQD., REMOVE TOP & CONVERT TO J-BOX

REQD., MILL EXISTING ASPHALT TO ALLOW

FOR REQD., ASPHALT LEVELING & OVERLAY

REQD., SAWCUT & REMOVE EXISTING ASPHALT

(SAWCUT TO PROVIDE SMOOTH EDGE)

REQD., SAWCUT TO PROVIDE SMOOTH EDGE

REQD., SAWCUT TO PROVIDE SMOOTH EGE

REQD., REMOVE 15LF OF ABANDONED 6" WATER LINE

REQD., REMOVE APPROX. 24LF

EXISTING 6" WATER LINE

6" GATE VALVES

REQD., REMOVE EX. PIPE END TREATMENT

AND APPROX. 10 LF EX. PIPE

REQD., REMOVE AND RELOCATE APPROX. 14LF EXISTING 6" WATER LINE

FOR STORM DRAINAGE INSTALLATION EFFORTS

REQD., REMOVE APPROX. 16LF OF ABANDONED 12" WATER LINE

FOR STORM DRAINAGE INSTALLATION EFFORTS

(PROPER DISPOSAL OF ASBESTOS-CEMENT PIPE REQUIRED)

REQD., REMOVE APPROX. 10LF OF ABANDONED 12" WATER LINE

FOR STORM DRAINAGE INSTALLATION EFFORTS

(PROPER DISPOSAL OF ASBESTOS-CEMENT PIPE REQUIRED)

REQD., SAWCUT AND REMOVE PORTION

OF EXIST. CONCRETE SIDEWALK

REQD., REMOVE EXISTING SIGN, SAVE AND RELOCATE

(COORD. WITH CITY FOR RELOCATION EFFORTS)

REQD., REMOVE EXISTING SIGN, SAVE AND RELOCATE

(COORD. WITH CITY FOR RELOCATION EFFORTS)

REQD., REMOVE EXISTING SIGN, SAVE AND RELOCATE

(COORD. WITH CITY FOR RELOCATION EFFORTS)

(REMAIN)

(REMAIN)

REQD., SAWCUT TO PROVIDE SMOOTH EDGE

REQD., REMOVE END TREATMENT

FOR STRUCTURE INSTALLATION

REQD., REMOVE 2 EA. EX. TREES

WITHIN PUBLIC R.O.W.

FOR WATERLINE INSTALLATION

(TO REMAIN)

(T O

RE

M

AI

N)

(TO REMAIN)

(TO REMAIN)

(REMOVE)(REMOVE)

(REMOVE)

(TO REM

AIN)

(REMOVE)(REMOVE)

(T O

RE

M

AI

N)

(T O

RE

M

AI

N)

DE

M

OL

IT

IO

N

PL

AN

C7

EA

ST

ND

S

TR

EE

T

IM

PR

OV

EM

EN

TS

CI

TY

O F

GU

LF

S

HO

RE

S

JOB NO:

SCALE:

DATE:

DRAFTER:

SHEET:

25-1998.20

JULY 2026

TLE/BLS/PWM

G re en o R d N o rt h S te

C

F ai rh o p e, A la b am a

P .O

B o x

F ai rh o p e, A la b am a

P h o n e:

-3 ja d en gi n ee rs .c o m

A

L

C A

-3 -E

AP

PR

DA

TE

RE

VI

SI

ON

NO

/2

0/

IS

SU

E

FO

R

BI

D

1.

1" = 20'

( IN FEET )

1 inch = ft.

GRAPHIC SCALE

UTILITY INFORMATION

CONTRACTOR SHALL HAVE ALL EXISTING BURIED UTILITIES

"LINE SPOTTED" BY CALLING 1-800-292-8925 (ALABAMA ONE-CALL)

OR BY CONTACTING LOCAL UTILITY COMPANIES

WATER/ SEWER:

GULF SHORES UTILITIES

RHONDA BUTLER - GENERAL MANAGER

(251) 968-6323 ext 3336 gsurbutler@gmail.com

1629 EAST 1ST ST, GULF SHORES, AL 36542

POWER:

BALDWIN EMC

KEN PIMPERL - (251) 989-0220

19600 STATE HIGHWAY 59, SUMMERDALE, AL 36580

GAS:

RIVIERA UTILITIES

JAMES WALLACE - (251) 943-5001

413 EAST LAUREL AVE, FOLEY, AL 36535

FIBER/ OTHER

COMMUNICATION:

BRIGHTSPEED

FORREST CHERNEY - (980) 376-1408

1120 SOUTH TRYON ST, SUITE 700, CHARLOTTE, NC 28203

Professional Land Surveyors

SURVEY PROVIDED BY:

Wattier Surveying, Inc.

EXISTING UTILITIES INDICATED ON THESE PLANS ARE BASED ON

AVAILABLE INFORMATION. CONTRACTOR IS REQUIRED TO VERIFY

LOCATION, BURY DEPTH, SIZE AND MATERIAL TYPE PRIOR TO ANY

UTILITY IMPROVEMENTS. THE ENGINEER SHALL BE NOTIFIED

IMMEDIATELY OF ANY DISCREPANCIES THAT ARE FOUND.

EXISTING UTILITIES DISCLAIMER:

1. TREES FOR REMOVAL ARE MARKED WITH A DEMOLITION "X".

2. CLEAR AND GRUB ALL AREAS WITHIN POND AND ROADWAY FOOTPRINTS.

3. ALL DEMOLITION TO BE DISPOSED OF IN ACCORDANCE WITH ALL LOCAL, STATE, AND

FEDERAL LAWS AND REGULATIONS.

DEMOLITION NOTE:

1. REQD, REMOVE / RELOCATE EXISTING COMMUNICATION BOX

PEDESTAL (COORDINATE WITH LOCAL UTILITY COMPANY)

2. EXISTING 12" WATERMAIN TO BE ABANDONED ONCE NEW WATERMAIN IS

ACTIVE - SEE SHEET C11-C12

3. WATERMAIN REMOVAL TASK CAN ONLY OCCUR ONCE NEW WATERMAIN IS

ACTIVE AND EXISTING HAS BEEN ABANDONED.

UTILITY NOTE:

W

V

WV

C

C

E E

E

C

E

C

C

C

C

C

C C

C

E

C

E

E E

W

C S

S

UGE UGE

U G

E

UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE UGE UGE UGE UGE UGE

UG

E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E

UGE

UGEUGEUGEUGEUGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E

UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE

UGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGE

UGE

UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE

C

C

W V

REQD., SAWCUT & REMOVE EXISTING ASPHALT

(SAWCUT TO PROVIDE SMOOTH EDGE)

REQD., SAWCUT & REMOVE EXISTING CONCRETE

(SAWCUT TO PROVIDE SMOOTH EDGE)

REQD., REMOVE EXISTING CONCRETE SIDEWALK

REQD., TO REMOVE

REQD., REMOVE EXISTING WOOD BARRIER

SEE UTILITY NOTE 1.

REQD., REMOVE EXISTING SIGN, SAVE AND RELOCATE

(COORD. WITH CITY FOR RELOCATION EFFORTS)

REQD., ADJUST RING & COVER FLUSH

REQD., MILL EXIST. ASPHALT W/IN HATCHED AREA, 1.25" MIN. THICKNESS

(REMAIN)

REQD., ADJUST RING & COVER

(RESET FLUSH W/ SIDEWALK)

REQD., REMOVE TOP & CONVERT TO J-BOX

REQD., MILL EXISTING ASPHALT TO ALLOW

FOR REQD., ASPHALT LEVELING & OVERLAY

REQD., SAWCUT & REMOVE EXISTING ASPHALT

(SAWCUT TO PROVIDE SMOOTH EDGE)

REQD., SAWCUT TO PROVIDE SMOOTH EDGE

REQD., SAWCUT TO PROVIDE SMOOTH EGE

REQD., REMOVE 15LF OF ABANDONED 6" WATER LINE

REQD., REMOVE APPROX. 16LF OF ABANDONED 12" WATER LINE

FOR STORM DRAINAGE INSTALLATION EFFORTS

(PROPER DISPOSAL OF ASBESTOS-CEMENT PIPE REQUIRED)

REQD., MILL EXIST. ASPHALT W/IN HATCHED AREA, 1.25" MIN. THICKNESS

REQD., REMOVE APPROX. 10LF OF ABANDONED 12" WATER LINE

FOR STORM DRAINAGE INSTALLATION EFFORTS

(PROPER DISPOSAL OF ASBESTOS-CEMENT PIPE REQUIRED)

REQD., REMOVE EXISTING SIGN, SAVE AND RELOCATE

(COORD. WITH CITY FOR RELOCATION EFFORTS)

REQD., REMOVE EXISTING SIGN, SAVE AND RELOCATE

(COORD. WITH CITY FOR RELOCATION EFFORTS)

(REMAIN)

(REMAIN)

REQD., SAWCUT TO PROVIDE SMOOTH EDGE

REQD., REMOVE END TREATMENT

FOR STRUCTURE INSTALLATION

(T O

RE

M

AI

N)

(TO REMAIN)

(TO REMAIN)

(TO REM

AIN)

REQD., SAWCUT & REMOVE EXISTING ASPHALT

(SAWCUT TO PROVIDE SMOOTH EDGE)

DE

M

OL

IT

IO

N

PL

AN

(2

EA

ST

ND

S

TR

EE

T

IM

PR

OV

EM

EN

TS

CI

TY

O F

GU

LF

S

HO

RE

S

JOB NO:

SCALE:

DATE:

DRAFTER:

SHEET:

25-1998.20

JULY 2026

TLE/BLS/PWM

G re en o R d N o rt h S te

C

F ai rh o p e, A la b am a

P .O

B o x

F ai rh o p e, A la b am a

P h o n e:

-3 ja d en gi n ee rs .c o m

A

L

C A

-3 -E

AP

PR

DA

TE

RE

VI

SI

ON

NO

/2

0/

IS

SU

E

FO

R

BI

D

1.

1" = 20'

( IN FEET )

1 inch = ft.

GRAPHIC SCALE

C8

Professional Land Surveyors

SURVEY PROVIDED BY:

Wattier Surveying, Inc.

UTILITY INFORMATION

CONTRACTOR SHALL HAVE ALL EXISTING BURIED UTILITIES

"LINE SPOTTED" BY CALLING 1-800-292-8925 (ALABAMA ONE-CALL)

OR BY CONTACTING LOCAL UTILITY COMPANIES

WATER/ SEWER:

GULF SHORES UTILITIES

RHONDA BUTLER - GENERAL MANAGER

(251) 968-6323 ext 3336 gsurbutler@gmail.com

1629 EAST 1ST ST, GULF SHORES, AL 36542

POWER:

BALDWIN EMC

KEN PIMPERL - (251) 989-0220

19600 STATE HIGHWAY 59, SUMMERDALE, AL 36580

GAS:

RIVIERA UTILITIES

JAMES WALLACE - (251) 943-5001

413 EAST LAUREL AVE, FOLEY, AL 36535

FIBER/ OTHER

COMMUNICATION:

BRIGHTSPEED

FORREST CHERNEY - (980) 376-1408

1120 SOUTH TRYON ST, SUITE 700, CHARLOTTE, NC 28203

1. TREES FOR REMOVAL ARE MARKED WITH A DEMOLITION "X".

2. CLEAR AND GRUB ALL AREAS WITHIN POND AND ROADWAY FOOTPRINTS.

3. ALL DEMOLITION TO BE DISPOSED OF IN ACCORDANCE WITH ALL LOCAL, STATE, AND

FEDERAL LAWS AND REGULATIONS.

DEMOLITION NOTE:

EXISTING UTILITIES INDICATED ON THESE PLANS ARE BASED ON

AVAILABLE INFORMATION. CONTRACTOR IS REQUIRED TO VERIFY

LOCATION, BURY DEPTH, SIZE AND MATERIAL TYPE PRIOR TO ANY

UTILITY IMPROVEMENTS. THE ENGINEER SHALL BE NOTIFIED

IMMEDIATELY OF ANY DISCREPANCIES THAT ARE FOUND.

EXISTING UTILITIES DISCLAIMER:

1. REQD, REMOVE / RELOCATE EXISTING COMMUNICATION BOX

PEDESTAL (COORDINATE WITH LOCAL UTILITY COMPANY)

2. EXISTING 12" WATERMAIN TO BE ABANDONED ONCE NEW WATERMAIN IS

ACTIVE - SEE SHEET C11-C12

3. WATERMAIN REMOVAL TASK CAN ONLY OCCUR ONCE NEW WATERMAIN IS

ACTIVE AND EXISTING HAS BEEN ABANDONED.

UTILITY NOTE:

C

C E

C

C

E

TR

C

C

C

C C C C

C

C

C

C

C

C

C

C

E

S

C

C

E E

E

E

E

EEE

E

E

C S

S E

E

C O

S

VAN

GOLF CART

ONLY

GOLF CART

ONLY

GOLF CART

ONLY

GOLF CART

ONLY

GOLF CART

ONLY

GOLF CART

ONLY

GOLF CART

ONLY

GOLF CART

ONLY

AL

T

AL

T

1BASE BID

C

C

STA=3+00

STA=3+50

STA=4+00

STA=4+50

STA=5+00

STA=5+50

STA=6+00

STA=6+50

STA=7+00

STA=3+00

STA=3+50

STA=4+00

STA=4+50

STA=5+00

STA=5+50

STA=6+00

STA=6+50

STA=7+00

REQD., LIGHT DUTY PAVEMENT, TYP.

REQD. SOLID WHITE 5", TYPE 2,

CLASS A THERMOPLASTIC TRAFFIC STRIPE, TYP.

REQD., 9' WIDE SIDEWALK, TYP.

REQD., ADA CURB RAMP, TYP.

REQD.ADA CURB RAMP, TYP.

REQD.9' WIDE SIDEWALK

REQD. SOLID WHITE 5", TYPE 2,

CLASS A THERMOPLASTIC TRAFFIC STRIPE, TYP.

REQD. 24" COMBINATION CURB AND GUTTER, TYP.

REQD., 24" COMBINATION CURB AND GUTTER, TYP.

REQD.CONCRETE DRIVEWAY, TYP.

REQD., CONCRETE DRIVEWAY

REQD, BRICK PAVERS, TYP.

REQD, BRICK PAVERS, TYP.

REQD., ADA CURB RAMP, TYP.

REQD., 1' WIDE FLUSH CURB, TYP.

REQD., CLAY BRICK PAVERS, TYP.

REQD, 24" STOP BAR (CLASS 2, TYPE A)

AND 30" STOP SIGN (R1-1)

REQD, BRICK PAVERS, TYP.

REQD., 9' WIDE SIDEWALK

CONNECT TO EX. (FLUSH)

RE

QD

PR

OP

OS

ED

0' R

.O .W

D

ED

IC

AT

IO

N

REQD., 9' WIDE SIDEWALK, TYP.

REQD., CLAY BRICK PAVERS, TYP.

REQD., 1' WIDE FLUSH CURB, TYP.

REQD., CONCRETE DRIVEWAY TO REPLACE EXIST.

(WIDTH SHALL MATCH EXISTING)

REQD, H/C RAMP

REQD.HEAVY DUTY PAVEMENT

REQD., LIGHT DUTY PAVEMENT, TYP.

REQD., HEAVY DUTY PAVEMENT TYP.

REQD., MILL AND OVERLAY

REQD., ADA CURB RAMP, TYP.

REQD., 24" COMBINATION

CURB AND GUTTER, TYP.

REQD., SOLID WHITE 5", TYPE 2,

CLASS A THERMOPLASTIC TRAFFIC STRIPE, TYP.

REQD., THERMOPLASTIC "GOLF CART ONLY" W/ STENCILREQD., THERMOPLASTIC "GOLF CART ONLY" W/ STENCIL

REQD., 6" CONCRETE HEADER CURB

REQD., 6" CONCRETE HEADER CURB

REQD., 6" CONCRETE

HEADER CURB

REQD., SOLID WHITE 5", TYPE 2,

CLASS A THERMOPLASTIC TRAFFIC STRIPE, TYP.

REQD., SOLID WHITE 5", TYPE 2,

CLASS A THERMOPLASTIC TRAFFIC STRIPE, TYP.

REQD.6' WIDE SIDEWALK

REQD, BRICK PAVERS, TYP.

REQD, 24" STOP BAR (CLASS 2, TYPE A)

AND 30" STOP SIGN (R1-1)

REQD, 24" STOP BAR (CLASS 2, TYPE A)

AND 30" STOP SIGN (R1-1)

REQD, 24" STOP BAR (CLASS 2, TYPE A)

AND 30" STOP SIGN (R1-1)

REQD., 1' WIDE FLUSH CURB, TYP.

REQD., 1' WIDE FLUSH CURB, TYP.

REQD., BENCHES, SEE

LANDSCAPE PLANS.

(SEE SHEET LP500)

REQD., 1' WIDE FLUSH CURB, TYP.

REQD., 1' WIDE FLUSH CURB, TYP.

STA:88+09.67

PHASE 1 BEGIN

STA:92+56.29

CENTERLINE 23RD AVENUE

& 2ND STREET

STA:88+31.09

CENTERLINE

22ND AVENUE

& 2ND STREET

REQD, BRICK PAVERS, TYP.

REQD, 24" STOP BAR (CLASS 2, TYPE A)

AND 30" STOP SIGN (R1-1)

ST

A=

+9

ST

A=

+5

STA=88+00

ST

A=

+5

ST

A=

+0

ST

A=

+5

ST

A=

+0

ST

A=

+5

ST

A=

+0

ST

A=

+5

ST

A=

+0

ST

A=

+5

REQD, BRICK PAVERS, TYP.

REQD., 1' WIDE FLUSH CURB, TYP.

STA:92+99.49

PHASE END

REQD., AGGREGATE SURFACE

(MATCH EXIST. CONDITIONS)

SI

TE

L

AY

OU

T

PA

VE

M

EN

T

PL

AN

EA

ST

ND

S

TR

EE

T

IM

PR

OV

EM

EN

TS

CI

TY

O F

GU

LF

S

HO

RE

S

JOB NO:

SCALE:

DATE:

DRAFTER:

SHEET:

25-1998.20

JULY 2026

TLE/BLS/PWM

G re en o R d N o rt h S te

C

F ai rh o p e, A la b am a

P .O

B o x

F ai rh o p e, A la b am a

P h o n e:

-3 ja d en gi n ee rs .c o m

A

L

C A

-3 -E

AP

PR

DA

TE

RE

VI

SI

ON

NO

/2

0/

IS

SU

E

FO

R

BI

D

1.

1" = 20'

( IN FEET )

1 inch = ft.

GRAPHIC SCALE

NOTES TO CONTRACTOR:

1. THE CONTRACTOR SHALL PROTECT AND MAINTAIN ANY EXISTING SLOPES AND

INFRASTRUCTURES ON THE SITE (I.E. PONDS, INLETS, ETC.).

2. CONTRACTOR TO VIDEO ALL EXISTING SEWER AND DRAIN LINES TO ENSURE THEY

ARE CLEAR AND IN PROPER WORKING ORDER. PROVIDE VIDEO TO THE OWNER.

3. AFTER THE STORM DRAIN SYSTEM IS COMPLETED THE CONTRACTOR SHALL VIDEO

THE SYSTEM AND SUBMIT VIDEO TO THE OWNER FOR REVIEW.

4. THE CONTRACTOR SHALL MAINTAIN ACCESS TO THE SITE FOR THE DURATION OF

THE PROJECT.

5. ALL EARTHWORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH

GEOTECHNICAL RECOMMENDATIONS.

6. ALL CONDUIT LOCATIONS FOR POWER, TELEPHONE, AND CABLE SHALL BE

COORDINATED WITH ARCHITECTURAL PLANS AND LOCAL UTILITY PROVIDERS.

C9

V

WV

C C

C E W

C

C

E

TR

C

C

C

C C C C

C

C

C

C

C

C

C

E

S

C

C

E E

E

E

E

EEE

W

W

W

E

E

C S

S E

E

W W

C O

S

VAN

PI: 3+00.07

PI: 3+67.30

PI: 4+38.22

PI: 4+83.01

PI: 5+83.94

PI: 6+12.15

PI: 6+69.59

PI: 7+04.26

PI: 5+96.15

PI: 2+81.41

PI: 4+72.35

PI

: 9

2+

.5

PI

: 9

2+

.6

EP

: 9

2+

.4

GOLF CART

ONLY

GOLF CART

ONLY

GOLF CART

ONLY

GOLF CART

ONLY

GOLF CART

ONLY

GOLF CART

ONLY

GOLF CART

ONLY

GOLF CART

ONLY

AL

T

AL

T

1BASE BID

C

C

STA=3+00

STA=3+50

STA=4+00

STA=4+50

STA=5+00

STA=5+50

STA=6+00

STA=6+50

STA=7+00

STA=3+00

STA=3+50

STA=4+00

STA=4+50

STA=5+00

STA=5+50

STA=6+00

STA=6+50

STA=7+00

STA:88+09.67

PHASE 1 BEGIN

STA:92+56.29

CENTERLINE 23RD AVENUE

& 2ND STREET

STA:88+31.09

CENTERLINE

22ND AVENUE

& 2ND STREET

ST

A=

+9

STA=88+00

ST

A=

+5

ST

A=

+0

ST

A=

+5

ST

A=

+0

ST

A=

+5

ST

A=

+0

ST

A=

+5

ST

A=

+0

ST

A=

+5

STA:92+99.49

PHASE END

GE

OM

ET

RI

C

CO

NT

RO

L

LA

YO

UT

EA

ST

ND

S

TR

EE

T

IM

PR

OV

EM

EN

TS

CI

TY

O F

GU

LF

S

HO

RE

S

JOB NO:

SCALE:

DATE:

DRAFTER:

SHEET:

25-1998.20

JULY 2026

TLE/BLS/PWM

G re en o R d N o rt h S te

C

F ai rh o p e, A la b am a

P .O

B o x

F ai rh o p e, A la b am a

P h o n e:

-3 ja d en gi n ee rs .c o m

A

L

C A

-3 -E

AP

PR

DA

TE

RE

VI

SI

ON

NO

/2

0/

IS

SU

E

FO

R

BI

D

1.

C10

1" = 20'

( IN FEET )

1 inch = ft.

GRAPHIC SCALE

C

C E W

C

C

E

TR

C

C

C

C

C C

C

C C

C

C C

C

C

C

C

C

C C

C

C C C C

C

C

C

C C

E

S

C

C

E E

E

E

E

EEE

W

W

W

E

E

C S

S

UGE

UGE

E E

W W

C O

UGE UGE UGE UGE UGE

UGE UGE UGE UGE UGE UGE UGE UGE UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UGE UGE UGE UGE UGE UGE

UG

E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U G

E U

G E

UGE

UGE

UGE

UGE

UGE

UGE

UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE UGE UGE UGE UGE UGE

UGE UGE UGE UGE UGE UGE

UGE UGE UGE UGE UGE UGE UGE

UGE

UGE

UGEUGE

UGE

UGEUGEUGEUGEUGE

U G

E U

G E

UGE

UGE

UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E

UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE

UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE

UGE

UGE

12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W

S

VAN

REQD; ADJUST EXIST. SANITARY SEWER

RING AND COVER TO FINISHED GRADE

REQD; ADJUST EXIST. SANITARY SEWER

RING AND COVER TO FINISHED GRADE

REQD; ADJUST EXIST. SANITARY SEWER

RING AND COVER TO FINISHED GRADE

C

C

STA=3+00

STA=3+50

STA=4+00

STA=4+50

STA=5+00

STA=5+50

STA=6+00

STA=6+50

STA=7+00

STA=3+00

STA=3+50

STA=4+00

STA=4+50

STA=5+00

STA=5+50

STA=6+00

STA=6+50

STA=7+00

STA:88+09.67

PHASE 1 BEGIN

STA:92+56.29

CENTERLINE 23RD AVENUE

& 2ND STREET

STA:88+31.09

CENTERLINE

22ND AVENUE

& 2ND STREET

REQD., CONNECT TO PROPOSED 12"

WATERMAIN W/ 12"X12"X12" TEE

12" GATE VALVE

APPROX. 10 LF 12" C900 PVC

W/ 12"X6" REDUCER

REQD., 2 - 12" 45° BEND

REQD., CONNECT TO PROPOSED

12" WATERMAIN W/ 12"X6" TEE

& 6" GATE VALVE

REQD., EXISTING 12" WATERMAIN TO BE

ABANDONED ONCE 12" WATERMAIN IS INSTALLED REQD., APPROX. 202 LF 12" C900 PVC

REQD., APPROX. 35 LF 12" C900 PVC

REQD., APPROX. 180 LF 12" C900 PVC

REQD., CONNECT TO

PROPOSED 12" WATERMAIN

W/ 12"X12"X12" TEE

12" GATE VALVE

12"X6" REDUCER

REQD., 12"X12" TEE W/

2 - 12" GATE VALVES

REQD., 2 - 6" 45° BEND

(AS NEEDED)

REQD., 2 - 6" 45° BEND

(AS NEEDED)

REQD., APPROX. 20LF 12" C900 PVC

REQD., 12" PLUG TO CAP PIPE

NOTE: CONTRACTOR TO INVESTIGATE AND FIELD VERIFY W/ LOCAL UTILITY

(SURVEY INDICATED TWO WATER VALVES IN THIS AREA - UTILITY G.I.S. SHOWS NO VALVES)

CONTRACTOR TO CONFIRM EXISTENCE OF WATER VALVES AND CONFIRM W/ ENGINEER

REQD., 6" INSERTVALVE (TEAM)

(LOCATION TO BE CONFIRMED W/ GSU)

RE

QD

" I

NS

ER

TV

AL

VE

(T

EA

M

(L

OC

AT

IO

N

TO

B E

CO

NF

IR

M

ED

W

/ G

SU

REQD., 12" GATE VALVE

REQD., IRRIGATION METER W/ B.F.P.

(SEE IRRIGATION PLAN FOR SIZE &

COORD. WITH LOCAL UTILITY)

REQD., EXISTING 12" WATERMAIN TO BE

ABANDONED ONCE 12" WATERMAIN IS INSTALLED

REQD., 12'X12" TAPPING SLEEVE & VALVE

REQD., APPROX. 40 LF 12" C900 PVC

REQD., 12" WATERMAIN TO BE INSTALLED BELOW STORM

REQD., 12" WATERMAIN TO BE INSTALLED

BELOW STORM

REQD., 12" WATERMAIN TO BE INSTALLED BELOW STORM

REQD., INSTALL 12" WATERMAIN

UNDER EX. CONCRETE CURB

REQD., 12" WATERMAIN TO BE INSTALLED BELOW STORM

REQD., INSTALL 12" WATERMAIN

UNDER EX. CONCRETE CURB

ST

A=

+9

ST

A=

+5

STA=88+00

ST

A=

+5

ST

A=

+0

ST

A=

+5

ST

A=

+0

ST

A=

+5

ST

A=

+0

ST

A=

+5

ST

A=

+0

ST

A=

+5

STA:92+99.49

PHASE END

NOTE: EX. 12" WATERMAIN IS ASBESTOS CEMENT PIPE

UT

IL

IT

Y

PL

AN

EA

ST

ND

S

TR

EE

T

IM

PR

OV

EM

EN

TS

CI

TY

O F

GU

LF

S

HO

RE

S

JOB NO:

SCALE:

DATE:

DRAFTER:

SHEET:

25-1998.20

JULY 2026

TLE/BLS/PWM

G re en o R d N o rt h S te

C

F ai rh o p e, A la b am a

P .O

B o x

F ai rh o p e, A la b am a

P h o n e:

-3 ja d en gi n ee rs .c o m

A

L

C A

-3 -E

AP

PR

DA

TE

RE

VI

SI

ON

NO

/2

0/

IS

SU

E

FO

R

BI

D

1.

1" = 20'

( IN FEET )

1 inch = ft.

GRAPHIC SCALE

NOTES TO CONTRACTOR:

1. THE CONTRACTOR SHALL PROTECT AND MAINTAIN ANY EXISTING SLOPES AND

INFRASTRUCTURES ON THE SITE (I.E. PONDS, INLETS, ETC.).

2. CONTRACTOR TO VIDEO ALL EXISTING SEWER AND DRAIN LINES TO ENSURE THEY

ARE CLEAR AND IN PROPER WORKING ORDER. PROVIDE VIDEO TO THE OWNER.

3. AFTER THE STORM DRAIN SYSTEM IS COMPLETED THE CONTRACTOR SHALL VIDEO

THE SYSTEM AND SUBMIT VIDEO TO THE OWNER FOR REVIEW.

4. THE CONTRACTOR SHALL MAINTAIN ACCESS TO THE SITE FOR THE DURATION OF

THE PROJECT.

5. ALL EARTHWORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH

GEOTECHNICAL RECOMMENDATIONS.

6. ALL CONDUIT LOCATIONS FOR POWER, TELEPHONE, AND CABLE SHALL BE

COORDINATED WITH ARCHITECTURAL PLANS AND LOCAL UTILITY PROVIDERS.

C11

UTILITY INFORMATION

CONTRACTOR SHALL HAVE ALL EXISTING BURIED UTILITIES

"LINE SPOTTED" BY CALLING 1-800-292-8925 (ALABAMA ONE-CALL)

OR BY CONTACTING LOCAL UTILITY COMPANIES

WATER/ SEWER:

GULF SHORES UTILITIES

RHONDA BUTLER - GENERAL MANAGER

(251) 968-6323 ext 3336 gsurbutler@gmail.com

1629 EAST 1ST ST, GULF SHORES, AL 36542

POWER:

BALDWIN EMC

KEN PIMPERL - (251) 989-0220

19600 STATE HIGHWAY 59, SUMMERDALE, AL 36580

GAS:

RIVIERA UTILITIES

JAMES WALLACE - (251) 943-5001

413 EAST LAUREL AVE, FOLEY, AL 36535

FIBER/ OTHER

COMMUNICATION:

BRIGHTSPEED

FORREST CHERNEY - (980) 376-1408

1120 SOUTH TRYON ST, SUITE 700, CHARLOTTE, NC 28203

V

WV

C

C

E E

E

C

E

C

C

C

C

C

C C

C

E

C

E

E E

W

C S

S

UGE UGE

U G

E

UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE UGE UGE UGE UGE UGE

UG

E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E

UGE

UGEUGEUGEUGEUGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E

UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE

UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE

12''W12''W12''W12''W

REQD; ADJUST EXIST. SANITARY SEWER

RING AND COVER TO FINISHED GRADE

REQD; ADJUST EXIST. SANITARY SEWER

RING AND COVER TO FINISHED GRADE

C

C

STA=4+00

STA=4+50

STA=5+00

STA=5+50

STA=6+00

STA=6+50

STA=7+00

REQD., EXISTING 12" WATERMAIN TO BE

ABANDONED ONCE 12" WATERMAIN IS INSTALLED

REQD., APPROX. 149 LF 12" C900 PVC

REQD., APPROX. 20 LF 12" C900 PVC

REQD., LIGHT DUTY PAVEMENT, TYP.

REQD., SOLID WHITE 5", TYPE 2,

CLASS A THERMOPLASTIC TRAFFIC STRIPE, TYP.

STA:92+56.29

CENTERLINE 23RD AVENUE

& 2ND STREET

REQD., CONNECT TO EXISTING 12" WATERMAIN AT EXISTING 12" GATE VALVE

REMOVE AND REPLACE EXIST. MEGALUG AS NEEDED

(COORD. W/ LOCAL UTILITY FOR EXACT LOCATION AND FOR LOCATION

OF UPSTREAM VALVES TO ISOLATE LINE FOR REMOVAL EFFORTS)

REQD., CONNECT TO PROPOSED 12"

WATERMAIN W/ 12"X12"X12" TEE

12" GATE VALVE

APPROX. 10 LF 12" C900 PVC

W/ 12"X6" REDUCER

REQD., 2 - 12" 45° BEND

REQD., APPROX. 202 LF 12" C900 PVC

REQD., APPROX. 35 LF 12" C900 PVC

REQD., 12" GATE VALVE

REQD., IRRIGATION METER W/ B.F.P.

(SEE IRRIGATION PLAN FOR SIZE &

COORD. WITH LOCAL UTILITY)

REQD., EXISTING 12" WATERMAIN TO BE

ABANDONED ONCE 12" WATERMAIN IS INSTALLED

REQD., 12" WATERMAIN TO BE INSTALLED BELOW STORM

REQD., INSTALL 12" WATERMAIN

UNDER EX. CONCRETE CURB

REQD., 12" WATERMAIN TO BE INSTALLED BELOW STORM

REQD., INSTALL 12" WATERMAIN

UNDER EX. CONCRETE CURB

ST

A=

+9

ST

A=

+5

ST

A=

+0

ST

A=

+5

STA:92+99.49

PHASE END

UT

IL

IT

Y

PL

AN

(2

EA

ST

ND

S

TR

EE

T

IM

PR

OV

EM

EN

TS

CI

TY

O F

GU

LF

S

HO

RE

S

JOB NO:

SCALE:

DATE:

DRAFTER:

SHEET:

25-1998.20

JULY 2026

TLE/BLS/PWM

G re en o R d N o rt h S te

C

F ai rh o p e, A la b am a

P .O

B o x

F ai rh o p e, A la b am a

P h o n e:

-3 ja d en gi n ee rs .c o m

A

L

C A

-3 -E

AP

PR

DA

TE

RE

VI

SI

ON

NO

/2

0/

IS

SU

E

FO

R

BI

D

1.

1" = 20'

( IN FEET )

1 inch = ft.

GRAPHIC SCALE

C12

NOTES TO CONTRACTOR:

1. THE CONTRACTOR SHALL PROTECT AND MAINTAIN ANY EXISTING SLOPES AND

INFRASTRUCTURES ON THE SITE (I.E. PONDS, INLETS, ETC.).

2. CONTRACTOR TO VIDEO ALL EXISTING SEWER AND DRAIN LINES TO ENSURE THEY

ARE CLEAR AND IN PROPER WORKING ORDER. PROVIDE VIDEO TO THE OWNER.

3. AFTER THE STORM DRAIN SYSTEM IS COMPLETED THE CONTRACTOR SHALL VIDEO

THE SYSTEM AND SUBMIT VIDEO TO THE OWNER FOR REVIEW.

4. THE CONTRACTOR SHALL MAINTAIN ACCESS TO THE SITE FOR THE DURATION OF

THE PROJECT.

5. ALL EARTHWORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH

GEOTECHNICAL RECOMMENDATIONS.

6. ALL CONDUIT LOCATIONS FOR POWER, TELEPHONE, AND CABLE SHALL BE

COORDINATED WITH ARCHITECTURAL PLANS AND LOCAL UTILITY PROVIDERS.

UTILITY INFORMATION

CONTRACTOR SHALL HAVE ALL EXISTING BURIED UTILITIES

"LINE SPOTTED" BY CALLING 1-800-292-8925 (ALABAMA ONE-CALL)

OR BY CONTACTING LOCAL UTILITY COMPANIES

WATER/ SEWER:

GULF SHORES UTILITIES

RHONDA BUTLER - GENERAL MANAGER

(251) 968-6323 ext 3336 gsurbutler@gmail.com

1629 EAST 1ST ST, GULF SHORES, AL 36542

POWER:

BALDWIN EMC

KEN PIMPERL - (251) 989-0220

19600 STATE HIGHWAY 59, SUMMERDALE, AL 36580

GAS:

RIVIERA UTILITIES

JAMES WALLACE - (251) 943-5001

413 EAST LAUREL AVE, FOLEY, AL 36535

FIBER/ OTHER

COMMUNICATION:

BRIGHTSPEED

FORREST CHERNEY - (980) 376-1408

1120 SOUTH TRYON ST, SUITE 700, CHARLOTTE, NC 28203

C

C E W

C

C

E

TR

C

C

C

C

C C C C

C

C

C

C

C

C

C

C

E

S

C

C

E E

E

E

E

EEE

W

W

W

E

E

C S

S

UGE

UGE

E E

W W

UGE UGE UGE UGE UGE

UGE UGE UGE UGE UGE UGE UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E

UGE

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UGE UGE UGE UGE UGE UGE

UG

E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U G

E U

G E

UGE

UGE

UGE

UGE

UGE

UGE

UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE UGE UGE UGE UGE UGE

UGE UGE UGE UGE UGE UGE UGE

UGE UGE UGE UGE UGE UGE UGE UGE

U G

E

UGE

UGE

UGEUGE

UGE

UGEUGEUGEUGEUGE

U G

E U

G E

U G

E

UGE

UGE

UGE

UGE

UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE

UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE

UGE

UGE

UGE

UGE

12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W

S

VAN

CONVERT TO

JUNCTION BOX

AL

T

AL

T

1BASE BID

C

C

STA=3+00

STA=3+50

STA=4+00

STA=4+50

STA=5+00

STA=5+50

STA=6+00

STA=6+50

STA=7+00

STA=2+50

STA=3+00

STA=3+50

STA=4+00

STA=4+50

STA=5+00

STA=5+50

STA=6+00

STA=6+50

STA=7+00

STA:88+09.67

PHASE 1 BEGIN

STA:92+56.29

CENTERLINE 23RD AVENUE

& 2ND STREET

STA:88+31.09

CENTERLINE

22ND AVENUE

& 2ND STREET

PDI-1

REQD., ALDOT TYPE PD INLET

RIM ELEV = 9.20

(N)22"x14" RCAP INV (OUT): 6.63

.1

T.

O.

C.

9.

.1

T.

O.

C.

9.

10.25 T.O.C.

9.75

10.60 T.O.C.

10.10

10.50 T.O.C.

10.00

10.95 T.O.C.

10.45

.8

T.

O.

C.

.3

10.95 T.O.C.

10.4510.85 T.O.C.

10.35 10.65 T.O.C.

10.1510.50 T.O.C.

10.0010.35 T.O.C.

9.85

9.95 T.O.C.

9.45

.5

T.

O.

C.

.0

11.10 T.O.C.

10.60

11.00 T.O.C.

10.50

10.50 T.O.C.

10.00

9.50 T.O.C.

9.00

10.15 T.O.C.

9.65

9.80 T.O.C.9.30

9.75 T.O.C.

9.25

9.50 T.O.C.9.00

10.00 T.O.C.

9.50

10.12 T.O.C.

9.62

9.80 T.O.C.9.30

10.00 T.O.C.9.50

10.60 T.O.C.

10.10

10.70 T.O.C.

10.20

10.70 T.O.C.

10.20

10.70 T.O.C.

10.20

9.80 T.O.C.

9.30

10.10 T.O.C.

9.60

10.00 T.O.C.

9.50

10.60 T.O.C.

10.45

10.75 T.O.C.

10.50

10.70 T.O.C.

10.20

10.80 T.O.C.

10.30

10.95 T.O.C.

10.45

10.85 T.O.C.

10.35

10.85 T.O.C.

10.35

10.95 T.O.C.

10.45

9.65 T.O.C.9.15

11.10 T.O.C.

10.60

10.75 T.O.C.

10.25

9.85 T.O.C.

9.35

9.

T .O

.C

9.

9.85 T.O.C.

9.35

10.50 T.O.C.

10.00

9.0010.20

10.009.85

10.40

10.55

10.30 10.15

9.95 9.85

9.

9.90

10.00

10.20

10.60 10.55

11.20

11.10

9.60

9.45

9.70 9.85

9.90

9.80

10.25

9.95

9.90

9.85

9.00

9.70

9.85

9.20 10.15

9.80

9.35

11.00

10.40

11.06

9.859.85

9.60 T.O.C.

9.10

10.00 T.O.C.

9.50

10.20 T.O.C.

9.70

9.60

9.60 T.O.C.

9.10

9.80 T.O.C.9.30

10.00

9.85

10.00

9.20

9.50

10.05

10.15 10.30

.1

T.

O.

C.

9.

.0

T.

O.

C.

9.

10.05 10.10

9.559.50

.7

T.

O.

C.

.2

.8

T.

O.

C.

.3

.7

T.

O.

C.

.2

10.90 T.O.C.

10.40

10.90 T.O.C.

10.40

11.25 T.O.C.

10.75

10.6010.50

.8

T.

O.

C.

.3

.7

T.

O.

C.

.2

10.80

10.60 T.O.C.

10.10

.7

T.

O.

C.

.2

10.60 T.O.C.

10.10

10.25

10.50 T.O.C.

10.25 10.60 T.O.C.

10.35

10.20

10.10 10.2510.10

11.50

9.60 9.659.65

10.30 T.O.C.

9.80

9.60

10.15 T.O.C.

9.65

9.55

10.00 9.90

9.90 9.80

9.65

10.30 T.O.C.

9.80

10.35 T.O.C.

9.85

10.20 T.O.C.

9.70

10.45 T.O.C.

9.95

9.70

10.65 T.O.C.

10.15

10.95

10.75 T.O.C.

10.25

10.50 T.O.C.

10.00

11.50

10.50 T.O.C.

10.00

.7

T.

O.

C.

.2

.6

T.

O.

C.

.1

10.10

10.60 T.O.C.

10.10

.5

T.

O.

C.

.0

10.80 T.O.C.

10.30

10.90 T.O.C.

10.40

11.00

10.90

10.90

10.90 T.O.C.

10.40

10.80 T.O.C.

10.30

10.55 T.O.C.

10.05

11.35 T.O.C.

10.85

10.65 T.O.C.

10.15

10.70 10.65

9.

10.65 T.O.C.

10.15

9.

9.50 9.70

9.

T .O

.C

9.

9.85 T.O.C.

9.60

9.75 T.O.C.

9.25

9.00

9.75

10.05 T.O.C.

9.55

10.20 T.O.C.

10.00

10.05 T.O.C.

9.80

.00

T.

O.C.

9.5

10.35 T.O.C.

9.85

.10

T.

O.C.

9.6

10.39 T.O.C.

9.89

9.9 0 T

.O.C.

9.4

10.00

9.35 T.O.C.

8.85

9.3 0 T

.O.C.

8.8

9.

10.25

11.00

10.90

9.95

10.20

MATCH EX. (FLUSH)

10.50 T.O.C.

10.00

10.65

10.70

9.45

9.65 T.O.C.

9.15

9.50 T.O.C.

9.00

9.75 T.O.C.

9.20

9.40 T.O.C.

8.90

9.85 T.O.C.

9.35

10.15 T.O.C.

9.65

REQD., 64LF 22" x 14" RCAP @ 0.25%

REQD., 10LF 18" RCP @ 0.00%

REQD., 29LF 18" RCP @ 0.25%

REQD., 60LF 18" RCP @ 0.25%

REQD., 92LF 24" RCP @ 0.15%

REQD., 80LF 30" DBL RCP @ 0.15%

REQD., 56LF 30"DBL RCP @ 0.15%

REQD., 132LF 24" RCP @…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .