This is a comprehensive planting and irrigation design plan prepared for the City of Gulf Shores, Alabama's Gulf Pines Improvement Project, specifically for E 2nd Street improvements between E 22nd Avenue and the Intracoastal Waterway. The project includes three planting plan segments (Base Bid, Bid Alternate #1, and sections from 23rd to 24th Avenue and 25th Avenue to Waterway E), with corresponding irrigation systems and landscape furnishings. The Base Bid planting plan specifies 14 Scarlet Crape Myrtles, 6 Southern Live Oaks, and 28 Bosque Elms as trees, along with 1,013 shrubs and groundcover plants across various species, plus 8,424 square feet of Tifway 419 Bermuda grass sod. Bid Alternate #1 reduces quantities to 4 Crape Myrtles, 2 Bosque Elms, and 138 shrub/groundcover plants with 2,586 square feet of sod. The 23rd to 24th Avenue section includes 16 trees and 732 shrubs/groundcovers with 9,455 square feet of sod, while the 25th to Waterway E section includes 16 trees and 1,090 shrubs/groundcovers with 12,108 square feet of sod. Site furnishings include 12 benches and 8 trash receptacles across various plan segments. The irrigation design incorporates Rain Bird sprinkler systems with multiple valve zones, approximately 5,366 to 5,692 linear feet of 1-inch PVC lateral lines, 935 to 1,361 linear feet of 2-inch mainline, and comprehensive grounding and surge protection systems. Sealed bids are due August 11, 2026, at 2:00 p.m., with a mandatory pre-bid conference on August 4, 2026, at 10:00 a.m.; construction is scheduled to begin September 8, 2026, with a contract term of 120 calendar days.
The project requires compliance with Alabama Safely Dig notification procedures, and all contractors must verify field conditions prior to commencing work, reporting any discrepancies between actual conditions and the anticipated conditions plan to the landscape architect and owner representative. Tree procurement pricing is to be separated from installation pricing, with the owner reserving the right to procure trees directly or require contractor procurement based on cost-effectiveness. All trees must be installed with RootAnchor underground tree stabilization systems or approved equivalents. Site preparation includes removal of existing sod, groundcover, weeds, and organic material, with all planting bed areas to receive 3 inches of longleaf pine straw mulch. The irrigation system includes dual check valve backflow preventers, wireless rain and freeze sensors, 2-inch flow sensors, and a 50-station Rain Bird controller with decoder-based system requiring proper grounding and surge protection installation. Contractors must verify all quantities noted on plans and report discrepancies to the landscape architect, as quantities are provided for bidding convenience only. The contract documentation indicates that minor differences between anticipated and actual field conditions are considered incidental to the work, but significant differing site conditions resulting in material scope changes may be addressed through the change order process subject to owner and landscape architect approval.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W
C
C
C
C
C
C
S
C
C
C
E
EE E
WW
W
C
C
W
C
C
C
E
TR
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
E
S
C
C
EE
E
E
E
E
E E
E
E
W
W
W
W
W
WV
WV
WV
E
S
E
CS SS
S C C
E EE
TV TV
W
W
W
W
W
WW
CO CO
C
C
C C
C
C
EE
W
W
C
E
TR
TRTR
TR TR
W
C
W
C
C
C
C
C
C
C
C
C
C
C CC
C
C
C
C C
C
C
C
C
C
C
C
C
CCC
C
C
S
S S
S
S
SSS
S
C C
C
C C C
C
C C
C
C
C
C
C
C C
E
E E E
E
E E E E
E
E
E E
E
U
W
W
W W
W
W
W
W
W x
PX
WW
W
W
CCC
C
C
W
W
E
FO
S W
W
S
S
W
W W
S
C
WV
ELEC
VAN
GO
LF
C
AR
T
PA
RK
IN
G
GO
LF
C
AR
T
PA
RK
IN
G
GO
LF
C
AR
T
PA
RK
IN
G
GO
LF
C
AR
T
PA
RK
IN
G
GOLF CART
PARKING
GOLF CART
PARKING
GOLF CART
PARKING
GOLF CART
PARKING
9 10 10
7 7
10 10
10 10
9 9
9 9
15 14
10 10
54 4
3 2
24" LIVE OAK
00 120' 240' landscape architecture land planning placemaking
Foley, Alabama P. 251.948.7181 www.was-design.com
Mobile, Alabama P. 251.344.4023
Jackson, Mississippi P. 601.790.0781 Pensacola, Florida P. 850.203.4252
NOT FOR CONSTRUCTION
N O
R T
HPLANTING PLAN1
NORTH
E. 22ND AVE
E. 24TH AVE
E.
R D
S T
E.
N D
S T
CANAL ROAD
KEY PLAN
E. 23RD AVE
WATERWAY E. BLVD
E.
N D
S T
E. 25TH AVE
INTRACOASTAL WATERWAY
LP200
LP201
LP202
C E W
C
C
TR
C
C
C
C C
C
CC
C
E
S
C E
E
E
E
E
EEE
W
W
W V W V
E
E
W W
S
W V
VAN
GOLF CART
PARKING
GOLF CART
PARKING
GOLF CART
PARKING
GOLF CART
PARKING
GOLF CART
PARKING
GOLF CART
PARKING
GOLF CART
PARKING
GOLF CART
PARKING
AL
T
AL
T
1BASE BID
12-02 12-02 12-01
(14) MC
(14) JD
(24) MC
(21) PD (21) PD
(28) LB
(11) MC
(25) RN (24) RN
(17) JD
(10) MC
(11) JD (14) PD
(15) PD
(31) LB
(20) RN
(7) MC
(22) RN
(17) JD
(23) MC
(19) MW
(30) HD (28) HD
(26) AG
(12) GL
(15) HD (12) HD (32) AG
(46) BF
(18) BF
(7) BE
(6) BE (5) BE
(2) LN
(2) LN
(1) BE
(6) QV
(8) BE
(8) LB
(30) BF
(8) LB
(9) DI
(9) DI
(1) BE
(19) MW
(46) BF
(9) DI
(8) LB
(18) BF
(9) DI
(8) LB
(30) BF
(2) LN
(10) LB
(7) LB
(7) LB
(7) LB
(2) BE
(4) LN
(9) DI (9) DI (9) DI (9) DI (9) DI (9) DI (9) DI (9) DI (9) DI (9) DI (9) DI
(9) DI (9) DI (9) DI (9) DI (9) DI (9) DI (9) DI
(25) BD
(10) BD
(16) BD (15) BD
(8) BD
(11) BD
(13) MW
(25) DV
(6) MW
(12) BD
(12) DV
(19) DV
(15) MW
(10) BD
(27) DV
(17) MW
(14) BD
(33) DV
(16) HD
(17) MC
(33) HD
(11) BD
(23) LB
(15) DV
(11) MC
(15) HD
SYMBOL CODE QTY BOTANICAL / COMMON NAME CONT CAL HT
TREES
LN 6 LAGERSTROEMIA X 'JM1' / SCARLET CRAPE MYRTLE
REFER TO TREE NOTES FOR ADDITIONAL DETAILS B & B 12`
QV 6 QUERCUS VIRGINIANA / SOUTHERN LIVE OAK
REFER TO TREE NOTES FOR ADDITIONAL DETAILS B & B 5.5" CAL
BE 28 ULMUS PARVIFOLIA `BOSQUE` / BOSQUE ELM
REFER TO TREE NOTES FOR ADDITIONAL DETAILS B & B 2"
SYMBOL CODE QTY BOTANICAL / COMMON NAME CONT HT SPACING
SHRUB AREAS
DI 198 DIANELLA TASMANICA 'VARIEGATA' / VARIEGATED FLAX LILY 3 GAL 18" o.c.
BD 132 DISTYLIUM 'BAYOU BLISS' / BAYOU BLISS DISTYLIUM 3 GAL 36" o.c.
JD 59 JUNIPERUS CHINENSIS `PARSONII` / PARSON`S JUNIPER 3 GAL 36" o.c.
LB 114 LOMANDRA LONGIFOLIA `BREEZE` / BREEZE GRASS 3 GAL 24" o.c.
MC 89 MUHLENBERGIA CAPILLARIS / PINK MUHLY 3 GAL 36" o.c.
MW 89 MUHLENBERGIA CAPILLARIS / WHITE CLOUD MUHLY 3 GAL 36" o.c.
RN 91 ROSA X `MEIGALPIO` / POPCORN DRIFT ROSE 3 GAL 24" o.c.
PD 71 ROSA X 'MEIZORLAND' / PEACH DRIFT ROSE 3 GAL 24" o.c.
GROUND COVERS
AG 58 AGAPANTHUS AFRICANUS `BLUE` / BLUE LILY OF THE NILE 1 GAL 18" o.c.
DV 83 DIETES VEGETA / WHITE AFRICAN IRIS 1 GAL 24" o.c.
BF 188 GAILLARDIA GRANDIFLORA / BLANKETFLOWER 1 GAL 15" o.c.
HD 118 HELIANTHUS DEBLIS / BEACH SUNFLOWER 1 GAL 24" o.c.
GL 12 LANTANA CAMARA 'NEW GOLD' / NEW GOLD LANTANA 1 GAL 24" o.c.
SOD/SEED
SOD 8,424 SF CYNODON DACTYLON `TIFWAY 419` / TIFWAY 419 BERMUDA GRASS SOD
PLANT SCHEDULE - BASE BID
SYMBOL CODE QTY BOTANICAL / COMMON NAME CONT CAL HT
TREES
LN 4 LAGERSTROEMIA X 'JM1' / SCARLET CRAPE MYRTLE
REFER TO TREE NOTES FOR ADDITIONAL DETAILS B & B 12`
BE 2 ULMUS PARVIFOLIA `BOSQUE` / BOSQUE ELM
REFER TO TREE NOTES FOR ADDITIONAL DETAILS B & B 2"
SYMBOL CODE QTY BOTANICAL / COMMON NAME CONT HT SPACING
SHRUB AREAS
LB 31 LOMANDRA LONGIFOLIA `BREEZE` / BREEZE GRASS 3 GAL 24" o.c.
MC 28 MUHLENBERGIA CAPILLARIS / PINK MUHLY 3 GAL 36" o.c.
GROUND COVERS
DV 48 DIETES VEGETA / WHITE AFRICAN IRIS 1 GAL 24" o.c.
HD 31 HELIANTHUS DEBLIS / BEACH SUNFLOWER 1 GAL 24" o.c.
SOD/SEED
SOD 2,586 SF CYNODON DACTYLON `TIFWAY 419` / TIFWAY 419 BERMUDA GRASS SOD
PLANT SCHEDULE - BID ALTERNATE #1
CODE DESCRIPTION QTY DETAIL
12 SITE FURNISHINGS
BENCH, MOUNTED ON PAVERS, 6' LONG, COVINGTON SLAT
OUTDOOR BENCH BY WABASH VALLEY, COLOR: SILVER. SKU:
CO1119CS02. WITH CONC. BENCH BASE UNDER PAVERS, 3,500
PSI CONCRETE, 8' LENGTH X 3'-8" WIDE
2 6/LP500
TRASH RECEPTACLE, MOUNTED ON PAVERS, EVERETT LITTER
RECEPTACLE BY KEYSTONE RIDGE, 32 GAL, ELEVATED LEGS,
COLOR: SPARKLE SILVER. WITH CONC. BASE UNDER PAVERS,
3,500 PSI CONCRETE, 3'-4" DIA.
2 7/LP500
12-01
12-02
REFERENCE NOTES SCHEDULE FURNITURE BASE BID
00 20' 40' landscape architecture land planning placemaking
Foley, Alabama P. 251.948.7181 www.was-design.com
Mobile, Alabama P. 251.344.4023
Jackson, Mississippi P. 601.790.0781 Pensacola, Florida P. 850.203.4252
NOT FOR CONSTRUCTION
N O
R T
H
Scale: 1" = 20'
PLANTING PLAN ENLARGEMENT1
QUANTITY TAKEOFF DISCLAIMER:
QUANTITIES NOTED ON PLANS ARE OFFERED AS A CONVENIENCE TO THE CONTRACTOR FOR BID
PURPOSES ONLY. CONTRACTOR SHALL VERIFY ALL QUANTITIES AND REPORT ANY
DISCREPANCIES TO THE LANDSCAPE ARCHITECT.
AlabamaSafely.Dig
800-292-8525 #DIG (Cellular) Call
FUTURE SIGNAGE
LOCATION, BY OTHERS.
FUTURE SIGNAGE
LOCATION, BY OTHERS.
NORTH
E. 22ND AVE
E. 24TH AVE
E.
R D
S T
E.
N D
S T
CANAL ROAD
KEY PLAN
E. 23RD AVE
WATERWAY E. BLVD
E.
N D
S T
E. 25TH AVE
INTRACOASTAL WATERWAY
TREE NOTES:
· THE OWNER HAS TAGGED SELECT TREES AT PANHANDLE GROWERS AS THE BASIS OF
DESIGN FOR MATERIAL QUALITY. THE CONTRACTOR SHALL PROVIDE A PRICE FOR TREE
PROCUREMENT, INCLUDING PURCHASE OF THE TAGGED TREES (OR APPROVED EQUAL),
COORDINATION, SHIPPING, FREIGHT, DELIVERY, AND ALL INCIDENTAL COSTS NECESSARY
TO DELIVER THE TREES TO THE PROJECT SITE. THIS PRICE SHALL BE ENTERED UNDER THE
"TREE PROCUREMENT & SHIPPING" BID ITEM. THE CONTRACTOR SHALL ALSO PROVIDE A
SEPARATE PRICE UNDER THE "TREE INSTALLATION" BID ITEM THAT INCLUDES RECEIVING,
UNLOADING, INSTALLATION, ROOT ANCHOR UNDERGROUND TREE STABILIZATION SYSTEM,
ESTABLISHMENT, MAINTENANCE, WARRANTY, AND ALL OTHER LABOR, MATERIALS, AND
INCIDENTALS REQUIRED FOR A COMPLETE INSTALLATION IN ACCORDANCE WITH THE
CONTRACT DOCUMENTS. THE OWNER RESERVES THE RIGHT TO PROCURE THE TREES
DIRECTLY AS AN OWNER-FURNISHED ITEM OR TO REQUIRE THE CONTRACTOR TO PROCURE
THE TREES, WHICHEVER PROCUREMENT METHOD IS DETERMINED TO BE MOST
ADVANTAGEOUS TO THE PROJECT.
· ALL TREES ARE TO BE INSTALLED WITH ROOTANCHOR UNDERGROUND TREE SUPPORT OR
APPROVED EQUAL.
C
C
E E
E
C
C
C
C
C S
S
C
C
C
C
C
C
S
E x x x x x x x x
C
ELEC
11 11
10 10
" LIV
E O
A K
" PA
LM
" W A
TER
O A K
" PA
LM
" LIV
E O
A K
(13) GL
(10) GL
(27) AG
(16) BD
(14) MC
(12) RA
(14) RA
(16) BD
(15) GL
(14) GL
(31) AG
(2) LN
(8) JB
(10) JB
(34) RN
(43) RN
(12) TD
(8) QV
(7) DV
(8) DV
(8) DV (8) DV (9) DV (6) DV (7) DV (8) DV
(9) RA
(8) DV (8) DV (8) DV (8) DV (9) DV (9) DV (8) DV (8) DV (8) DV
(15) RA
(2) LN
(34) DI
(3) PD
(30) PD
(17) MC
(60) PD
(28) MC
(65) DI
(21) BD
(21) MC
(35) DI
(29) HD
(22) MW(22) MW
(30) HD
(12) TD
(34) PD (5) PD
(22) MC
(50) DI
(12) MC
(39) DI
(37) DI
(11) MC
12-03 12-04
12-03 12-04
32-01
32-01
12-04
32-01
12-03
12-04 32-01 12-03
SYMBOL CODE QTY BOTANICAL / COMMON NAME CONT CAL HT
TREES
LN 4 LAGERSTROEMIA X 'JM1' / SCARLET CRAPE MYRTLE
REFER TO TREE NOTES FOR ADDITIONAL DETAILS B & B 12`
QV 8 QUERCUS VIRGINIANA / SOUTHERN LIVE OAK
REFER TO TREE NOTES FOR ADDITIONAL DETAILS B & B 5.5" CAL
TD 24 TAXODIUM DISTICHUM / BALD CYPRESS
FULL HEAD, SPECIMEN QUALITY B & B 3"CAL
SYMBOL CODE QTY BOTANICAL / COMMON NAME CONT HT SPACING
SHRUBS
RA 50 ABELIA X GRANDIFLORA `ROSE CREEK` / ROSE CREEK ABELIA 3 GAL 42" o.c.
SHRUB AREAS
DI 260 DIANELLA TASMANICA 'VARIEGATA' / VARIEGATED FLAX LILY 3 GAL 18" o.c.
BD 53 DISTYLIUM 'BAYOU BLISS' / BAYOU BLISS DISTYLIUM 3 GAL 36" o.c.
MC 125 MUHLENBERGIA CAPILLARIS / PINK MUHLY 3 GAL 36" o.c.
MW 44 MUHLENBERGIA CAPILLARIS / WHITE CLOUD MUHLY 3 GAL 36" o.c.
RN 77 ROSA X `MEIGALPIO` / POPCORN DRIFT ROSE 3 GAL 24" o.c.
PD 132 ROSA X 'MEIZORLAND' / PEACH DRIFT ROSE 3 GAL 24" o.c.
GROUND COVERS
AG 58 AGAPANTHUS AFRICANUS `BLUE` / BLUE LILY OF THE NILE 1 GAL 18" o.c.
DV 135 DIETES VEGETA / WHITE AFRICAN IRIS 1 GAL 24" o.c.
HD 59 HELIANTHUS DEBLIS / BEACH SUNFLOWER 1 GAL 24" o.c.
JB 18 JUNIPERUS CONFERTA 'BLUE PACIFIC' / BLUE PACIFIC SHORE JUNIPER 1 GAL 36" o.c.
GL 52 LANTANA CAMARA 'NEW GOLD' / NEW GOLD LANTANA 1 GAL 24" o.c.
SOD/SEED
SOD 9,455 SF CYNODON DACTYLON `TIFWAY 419` / TIFWAY 419 BERMUDA GRASS SOD
PLANT SCHEDULE - 23RD TO 24TH
CODE DESCRIPTION QTY DETAIL
12 SITE FURNISHINGS
BENCH, MOUNTED ON CONCRETE, 6' LONG, COVINGTON SLAT
OUTDOOR BENCH BY WABASH VALLEY, COLOR: SILVER. SKU:
CO1119CS02. WITH CONC. BENCH BASE UNDER PAVERS, 3,500
PSI CONCRETE, 8' LENGTH X 3'-8" WIDE
4 9/LP500
TRASH RECEPTACLE, MOUNTED ON CONCRETE, EVERETT
LITTER RECEPTACLE BY KEYSTONE RIDGE, 32 GAL, ELEVATED
LEGS, COLOR: SPARKLE SILVER. WITH CONC. BASE UNDER
PAVERS, 3,500 PSI CONCRETE, 3'-4" DIA.
4 10/LP500
32 EXTERIOR IMPROVEMENTS
CONCRETE PAVING, FINISH TO MATCH ADJACENT CONCRETE
PAVING
377 SF 8/LP500
12-03
12-04
32-01
REFERENCE NOTES SCHEDULE 23RD TO 24TH
00 20' 40' landscape architecture land planning placemaking
Foley, Alabama P. 251.948.7181 www.was-design.com
Mobile, Alabama P. 251.344.4023
Jackson, Mississippi P. 601.790.0781 Pensacola, Florida P. 850.203.4252
NOT FOR CONSTRUCTION
AlabamaSafely.Dig
800-292-8525 #DIG (Cellular) Call
NORTH
E. 22ND AVE
E. 24TH AVE
E.
R D
S T
E.
N D
S T
CANAL ROAD
KEY PLAN
E. 23RD AVE
WATERWAY E. BLVD
E.
N D
S T
E. 25TH AVE
QUANTITY TAKEOFF DISCLAIMER:
QUANTITIES NOTED ON PLANS ARE OFFERED AS A CONVENIENCE TO THE CONTRACTOR FOR BID
PURPOSES ONLY. CONTRACTOR SHALL VERIFY ALL QUANTITIES AND REPORT ANY
DISCREPANCIES TO THE LANDSCAPE ARCHITECT.
N O
R T
H
Scale: 1" = 20'
PLANTING PLAN ENLARGEMENT1
INTRACOASTAL WATERWAY
DEMOLITION NOTE:
IN ALL AREAS WHERE LANDSCAPE, IRRIGATION, OR OTHER SITE IMPROVEMENTS ARE INDICATED, REMOVE EXISTING SOD, GROUNDCOVER, WEEDS, ORGANIC MATERIAL, DEBRIS, AND OTHER
SURFACE MATERIALS AS NECESSARY TO ACCOMMODATE THE NEW WORK. PREPARE SUBGRADE,
FINISH GRADES, AND TOPSOIL IN ACCORDANCE WITH THE DRAWINGS AND PROJECT
SPECIFICATIONS. PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, DISPOSAL, AND INCIDENTAL
WORK REQUIRED TO COMPLETE SITE PREPARATION FOR THE PROPOSED IMPROVEMENTS.
TREE NOTES:
· THE OWNER HAS TAGGED SELECT TREES AT PANHANDLE GROWERS AS THE BASIS OF
DESIGN FOR MATERIAL QUALITY. THE CONTRACTOR SHALL PROVIDE A PRICE FOR TREE
PROCUREMENT, INCLUDING PURCHASE OF THE TAGGED TREES (OR APPROVED EQUAL),
COORDINATION, SHIPPING, FREIGHT, DELIVERY, AND ALL INCIDENTAL COSTS NECESSARY
TO DELIVER THE TREES TO THE PROJECT SITE. THIS PRICE SHALL BE ENTERED UNDER THE
"TREE PROCUREMENT & SHIPPING" BID ITEM. THE CONTRACTOR SHALL ALSO PROVIDE A
SEPARATE PRICE UNDER THE "TREE INSTALLATION" BID ITEM THAT INCLUDES RECEIVING,
UNLOADING, INSTALLATION, ROOT ANCHOR UNDERGROUND TREE STABILIZATION SYSTEM,
ESTABLISHMENT, MAINTENANCE, WARRANTY, AND ALL OTHER LABOR, MATERIALS, AND
INCIDENTALS REQUIRED FOR A COMPLETE INSTALLATION IN ACCORDANCE WITH THE
CONTRACT DOCUMENTS. THE OWNER RESERVES THE RIGHT TO PROCURE THE TREES
DIRECTLY AS AN OWNER-FURNISHED ITEM OR TO REQUIRE THE CONTRACTOR TO PROCURE
THE TREES, WHICHEVER PROCUREMENT METHOD IS DETERMINED TO BE MOST
ADVANTAGEOUS TO THE PROJECT.
AS-BUILT SURVEY NOTES
THE AS-BUILT SURVEY PROVIDED IN THIS PLAN SET REPRESENTS SITE CONDITIONS AT
THE TIME THE SURVEY WAS PERFORMED. THE ROADWAY AND ASSOCIATED
INFRASTRUCTURE WERE UNDER CONSTRUCTION AT THAT TIME. THE AS-BUILT SURVEY
IS INCLUDED FOR REFERENCE ONLY AND DOES NOT NECESSARILY REPRESENT THE
SITE CONDITIONS THAT WILL EXIST AT THE START OF THIS CONTRACT. REFER TO
AC202 FOR ADDITIONAL INFORMATION.
E 2ND STREET
130' - R/W
E 2
TH
A V E
' - R /W
W A
TER
W A
Y EA
S T B
O U
LEV
A R D
' - R /W
E 2
TH
A V E
' - R /W
E 2
TH
A V E
' - R /W
00 20' 40' landscape architecture land planning placemaking
Foley, Alabama P. 251.948.7181 www.was-design.com
Mobile, Alabama P. 251.344.4023
Jackson, Mississippi P. 601.790.0781 Pensacola, Florida P. 850.203.4252
NOT FOR CONSTRUCTION
NORTH
E. 22ND AVE
E. 24TH AVE
E.
R D
S T
E.
N D
S T
CANAL ROAD
KEY PLAN
E. 23RD AVE
WATERWAY E. BLVD
E.
N D
S T
E. 25TH AVE
INTRACOASTAL WATERWAY
N O
R T
H
Scale: 1" = 20'
ANTICIPATED CONDITIONS PLAN1
AS-BU
ILT SU
R
VEY
LIN
EW
O R
K
AN
TIC
IPATED
C O
N D
ITIO
N
S
LIN
EW
O
R K
AS-BU
ILT SU
R
VEY
LIN
EW
O R
K
AN
TIC
IPATED
C O
N D
ITIO
N
S
LIN
EW
O
R K
AS-BU
ILT SU
R
VEY
LIN
EW
O R
K
AN
TIC
IPATED
C O
N D
ITIO
N
S
LIN
EW
O
R K
ANTICIPATED CONDITIONS NOTES
· THE ANTICIPATED CONDITIONS PLAN HAS BEEN PREPARED USING THE AVAILABLE
AS-BUILT SURVEY INFORMATION AND THE OWNER'S/ENGINEER'S EXPECTED
COMPLETED ROADWAY IMPROVEMENTS. THIS PLAN REPRESENTS THE DESIGN
TEAM'S BEST ESTIMATE OF THE SITE CONDITIONS EXPECTED TO EXIST WHEN THIS
CONTRACT COMMENCES.
· THE CONTRACTOR SHALL VERIFY ALL EXISTING FIELD CONDITIONS PRIOR TO
COMMENCING WORK. MINOR DIFFERENCES BETWEEN ACTUAL FIELD CONDITIONS
AND THE ANTICIPATED CONDITIONS SHOWN ON THE PLANS SHALL BE CONSIDERED
INCIDENTAL TO THE WORK.
· IF THE CONTRACTOR IDENTIFIES SIGNIFICANT DIFFERENCES BETWEEN ACTUAL
FIELD CONDITIONS AND THE ANTICIPATED CONDITIONS SHOWN ON THE PLANS
THAT MAY IMPACT THE WORK, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE
OWNER'S REPRESENTATIVE AND THE LANDSCAPE ARCHITECT PRIOR TO
PROCEEDING WITH THE AFFECTED WORK. THE CONTRACTOR SHALL NOT
PROCEED WITH THE AFFECTED WORK UNTIL DIRECTION IS RECEIVED.
· DOCUMENTED DIFFERING SITE CONDITIONS THAT RESULT IN A MATERIAL CHANGE
TO THE SCOPE OF WORK MAY BE ADDRESSED THROUGH THE CONTRACT CHANGE
ORDER PROCESS, SUBJECT TO REVIEW AND APPROVAL BY THE OWNER.
E 2
TH
A
V E
' - R
/W
W A
TER
W A
Y EA
S T B
O U
LEV
A R D
' - R
/W
E 2
TH
A
V E
' - R
/W
E 2
TH
A
V E
' - R
/W
(5) LB
(8) LB
(8) QV
(14) BE
(2) LN
(14) BE
(2) LN
(20) HD
(10) JB
(16) PD
(21) GL
(19) GL
(19) PD
(23) PD
(13) BD
(16) MW
(26) HD
(27) PD
(22) GL
(11) GL
(11) MW
(14) BD
(7) BD
(12) MW
(9) LB(8) LB(10) LB(9) LB(8) LB(8) LB(9) LB(8) LB
(5) LB(5) LB(5) LB(8) LB(8) LB(8) LB(8) LB
(47) BF
(11) MW
(12) JB
(22) PD
(21) PD
(11) JB
(45) BF
(16) MW
(34) HD
(22) MC
(36) RN
(28) MW
(25) DV
(19) BD
(17) MW
(41) DV
(38) DV
(29) MW
(18) RN
(22) DV
(36) MW
(16) BD
(12) MW
(21) DV
(2) RN
(49) RN
(32) RN
(22) MW
(21) DV(16) BD
(17) MW
(39) DV
(34) HD
(22) MC
(3) LN
(58) MS
(15) PD
(12) BD
12-04
12-03
12-04
12-03
32-01
32-01
(13) MW
32-01
12-03
12-04
12-03 32-01 12-04
SYMBOL CODE QTY BOTANICAL / COMMON NAME CONT CAL HT
TREES
LN 7 LAGERSTROEMIA X 'JM1' / SCARLET CRAPE MYRTLE
REFER TO TREE NOTES FOR ADDITIONAL DETAILS B & B 12`
QV 8 QUERCUS VIRGINIANA / SOUTHERN LIVE OAK
REFER TO TREE NOTES FOR ADDITIONAL DETAILS B & B 5.5" CAL
BE 28 ULMUS PARVIFOLIA `BOSQUE` / BOSQUE ELM
REFER TO TREE NOTES FOR ADDITIONAL DETAILS B & B 2"
SYMBOL CODE QTY BOTANICAL / COMMON NAME CONT HT SPACING
SHRUBS
MS 58 MISCANTHUS SINENSIS 'ADAGIO' / ADAGIO EULALIA GRASS 3 GAL 36" o.c.
SHRUB AREAS
BD 97 DISTYLIUM 'BAYOU BLISS' / BAYOU BLISS DISTYLIUM 3 GAL 36" o.c.
LB 129 LOMANDRA LONGIFOLIA `BREEZE` / BREEZE GRASS 3 GAL 24" o.c.
MC 44 MUHLENBERGIA CAPILLARIS / PINK MUHLY 3 GAL 36" o.c.
MW 240 MUHLENBERGIA CAPILLARIS / WHITE CLOUD MUHLY 3 GAL 36" o.c.
RN 137 ROSA X `MEIGALPIO` / POPCORN DRIFT ROSE 3 GAL 24" o.c.
PD 143 ROSA X 'MEIZORLAND' / PEACH DRIFT ROSE 3 GAL 24" o.c.
GROUND COVERS
DV 207 DIETES VEGETA / WHITE AFRICAN IRIS 1 GAL 24" o.c.
BF 92 GAILLARDIA GRANDIFLORA / BLANKETFLOWER 1 GAL 15" o.c.
HD 114 HELIANTHUS DEBLIS / BEACH SUNFLOWER 1 GAL 24" o.c.
JB 33 JUNIPERUS CONFERTA 'BLUE PACIFIC' / BLUE PACIFIC SHORE JUNIPER 1 GAL 36" o.c.
GL 73 LANTANA CAMARA 'NEW GOLD' / NEW GOLD LANTANA 1 GAL 24" o.c.
SOD/SEED
SOD 12,108 SF CYNODON DACTYLON `TIFWAY 419` / TIFWAY 419 BERMUDA GRASS SOD
PLANT SCHEDULE 25TH TO WATERWAY E
CODE DESCRIPTION QTY DETAIL
12 SITE FURNISHINGS
BENCH, MOUNTED ON CONCRETE, 6' LONG, COVINGTON SLAT
OUTDOOR BENCH BY WABASH VALLEY, COLOR: SILVER. SKU:
CO1119CS02. WITH CONC. BENCH BASE UNDER PAVERS, 3,500
PSI CONCRETE, 8' LENGTH X 3'-8" WIDE
4 9/LP500
TRASH RECEPTACLE, MOUNTED ON CONCRETE, EVERETT
LITTER RECEPTACLE BY KEYSTONE RIDGE, 32 GAL, ELEVATED
LEGS, COLOR: SPARKLE SILVER. WITH CONC. BASE UNDER
PAVERS, 3,500 PSI CONCRETE, 3'-4" DIA.
4 10/LP500
32 EXTERIOR IMPROVEMENTS
CONCRETE PAVING, FINISH TO MATCH ADJACENT CONCRETE
PAVING
344 SF 8/LP500
12-03
12-04
32-01
REFERENCE NOTES SCHEDULE 25TH TO WATERWAY E
00 20' 40' landscape architecture land planning placemaking
Foley, Alabama P. 251.948.7181 www.was-design.com
Mobile, Alabama P. 251.344.4023
Jackson, Mississippi P. 601.790.0781 Pensacola, Florida P. 850.203.4252
NOT FOR CONSTRUCTION
AlabamaSafely.Dig
800-292-8525 #DIG (Cellular) Call
NORTH
E. 22ND AVE
E. 24TH AVE
E.
R D
S T
E.
N D
S T
CANAL ROAD
KEY PLAN
E. 23RD AVE
WATERWAY E. BLVD
E.
N D
S T
E. 25TH AVE
N O
R T
H
Scale: 1" = 20'
PLANTING PLAN ENLARGEMENT1
INTRACOASTAL WATERWAY
DEMOLITION NOTE:
IN ALL AREAS WHERE LANDSCAPE, IRRIGATION, OR OTHER SITE IMPROVEMENTS ARE INDICATED, REMOVE EXISTING SOD, GROUNDCOVER, WEEDS, ORGANIC MATERIAL, DEBRIS, AND OTHER
SURFACE MATERIALS AS NECESSARY TO ACCOMMODATE THE NEW WORK. PREPARE SUBGRADE,
FINISH GRADES, AND TOPSOIL IN ACCORDANCE WITH THE DRAWINGS AND PROJECT
SPECIFICATIONS. PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, DISPOSAL, AND INCIDENTAL
WORK REQUIRED TO COMPLETE SITE PREPARATION FOR THE PROPOSED IMPROVEMENTS.
QUANTITY TAKEOFF DISCLAIMER:
QUANTITIES NOTED ON PLANS ARE OFFERED AS A CONVENIENCE TO THE CONTRACTOR FOR BID
PURPOSES ONLY. CONTRACTOR SHALL VERIFY ALL QUANTITIES AND REPORT ANY
DISCREPANCIES TO THE LANDSCAPE ARCHITECT.
TREE NOTES:
· THE OWNER HAS TAGGED SELECT TREES AT PANHANDLE GROWERS AS THE BASIS OF
DESIGN FOR MATERIAL QUALITY. THE CONTRACTOR SHALL PROVIDE A PRICE FOR TREE
PROCUREMENT, INCLUDING PURCHASE OF THE TAGGED TREES (OR APPROVED EQUAL),
COORDINATION, SHIPPING, FREIGHT, DELIVERY, AND ALL INCIDENTAL COSTS NECESSARY
TO DELIVER THE TREES TO THE PROJECT SITE. THIS PRICE SHALL BE ENTERED UNDER THE
"TREE PROCUREMENT & SHIPPING" BID ITEM. THE CONTRACTOR SHALL ALSO PROVIDE A
SEPARATE PRICE UNDER THE "TREE INSTALLATION" BID ITEM THAT INCLUDES RECEIVING,
UNLOADING, INSTALLATION, ROOT ANCHOR UNDERGROUND TREE STABILIZATION SYSTEM,
ESTABLISHMENT, MAINTENANCE, WARRANTY, AND ALL OTHER LABOR, MATERIALS, AND
INCIDENTALS REQUIRED FOR A COMPLETE INSTALLATION IN ACCORDANCE WITH THE
CONTRACT DOCUMENTS. THE OWNER RESERVES THE RIGHT TO PROCURE THE TREES
DIRECTLY AS AN OWNER-FURNISHED ITEM OR TO REQUIRE THE CONTRACTOR TO PROCURE
THE TREES, WHICHEVER PROCUREMENT METHOD IS DETERMINED TO BE MOST
ADVANTAGEOUS TO THE PROJECT.
landscape architecture land planning placemaking
Foley, Alabama P. 251.948.7181 www.was-design.com
Mobile, Alabama P. 251.344.4023
Jackson, Mississippi P. 601.790.0781 Pensacola, Florida P. 850.203.4252
NOT FOR CONSTRUCTION
R O
O
TB
AL
L
1"
2 X ROOTBALL
UNDISTURBED SUBGRADE
ROOTBALL
AT BACKFILL AWAY FROM
ROOTBALL.
AT WATER WELL.
MULCH TO DEPTH
FINISHED GRADE.
1 " HIGHER
SLOPE FINISHED GRADE
FINISHED GRADE.
THAN SURROUNDING
SET ROOTBALL CROWNFORM 3"
CONTINUOUS
SAUCER AROUND
PLANTING PIT
BACKFILL WITH A MIXTURE
OF PLANTING PIT SPOIL AND
PREPARED PLANTING SOIL,
PER SPECS, FROM
ADJACENT PLANTING AREA
PLANTING TABLETS,
AGRIFORM OR EQUAL, PER
MANUF. RECOMMENDATIONS.
SHRUB PLANTING
1" = 1'-0"
329333.13-01
SHRUBS AND GROUNDCOVERS ADJACENT TO STRAIGHT EDGES SHALL BE
TRIANGULAR - SPACED IN ROWS PARALLED TO THE STRAIGHT EDGE.
SHRUBS AND GROUNDCOVERS ADJACENT TO CURVED EDGES SHALL BE
PLANTED IN ROWS PARALLEL TO THE CURVED EDGES. CURVED EDGES TO
BE VERY SMOOTH RADII.
A
A
B
B
BEDLINE
CURB
TYPICAL PLANT SPACING
NOT TO SCALE
329399-04
CROWN MULCH NEAR EDGE
IN A BERM-LIKE MANNER
AS SHOWN
LAWN
OR TOP OF CURB/
PAVING GRADE
10"
4"
PREPARED
SUBGRADE
1"3"
3"
NOTE: TRENCH EDGE TO BE LOCATED BETWEEN ALL PLANTING BED
AREAS AND ADJACENT TURF AREAS, UNLESS NOTED OTHERWISE.
MULCH LAYER
TRENCH EDGE
3" = 1'-0" 329413.23-02
GROUNDCOVER PLANTING
3" = 1'-0"
PLANT SPACING PER
PLAN/PLANT SCHEDULE
2" MULCH INSTALLED BEFORE
PLANTING (PINE BARK
MINI-NUGGETS ACCEPTABLE FOR
INITIAL PLANTING IF TIGHT
SPACING NECESSITATES ITS
USE.)
PREPARE BED PER SPECS
UNDISTURBED SUBGRADE
329313-01
PLANTING AT
SHRUB AREAS.
PLANTING AT
TURF AREAS.
SPECIFIED PLANTING
MIX. WATER AND TAMP
TO REMOVE AIR
POCKETS.
TREE PLANTING DETAIL
1" = 1'-0"
329343.13-01
BENCH INSTALL ON UNIT PAVERS
3/4" = 1'-0"
5"
CONC. BENCH BASE, 5"
THICK, 3,500 PSI CONCRETE
W/ WELDED WIRE FABRIC
(WWF) 6x6x10/10, 8' LENGTH X 3'-8" WIDE 1
1/2" ANCHOR BOLT AT EACH LEG.
CUT BOLT 1/16" PROUD OF NUT AND
PEEN END TO LOCK NUT.
BENCH, RE: PLANS
FOR INFORMATION.
RE: MANUF.
DETAIL FOR
ANCHOR
LAYOUT
3'-8"
FINISHED
GRADE
3"
S-FU-42
1/2" ANCHOR BOLT AT
EACH LEG. CUT BOLT 1/16"
PROUD OF NUT AND PEEN
END TO LOCK NUT.
5"
3'-4" DIA.
TRASH RECEPTACLE ON UNIT PAVERS
3/4" = 1'-0"
FINISHED
GRADE
TRASH RECEPTACLE,
RE: PLANS
RE: MANUF.
DETAIL FOR
ANCHOR
LAYOUT
CONC. BASE, 5" THICK, 3,500
PSI CONCRETE W/ WELDED
WIRE FABRIC (WWF)
6x6x10/10, 8' LENGTH X 3'-8" WIDE
3"
S-FU-39
SAWED CONTROL JOINT SECTION
CONCRETE PAVING
1 1/2" = 1'-0"
TYP. CONC. PAVING SECTION EXPANSION/CONSTRUCTION JOINT SECTION
2" 8" 8" 2"
8"
3"
PREPARED SUBGRADE,
TYP.
5"
5" THICK, 3,500 PSI CONCRETE PAVING, FINISH
TO MATCH ADJACENT CONCRETE PAVING.
WELDED WIRE FABRIC (WWF),
6x6x10/10, TYP.
4"
1/4" SAWCUT CONTROL
JOINT, DEPTH EQUAL TO
1/4 SLAB, @ 5' O.C. 1/2" FELT EXPANSION JOINT W/
1/2" WATERPROOF SEALANT,
FULL DEPTH
321313.16-06
1/2" ANCHOR BOLT AT EACH LEG.
CUT BOLT 1/16" PROUD OF NUT AND
PEEN END TO LOCK NUT.
BENCH, RE: PLANS
FOR INFORMATION.
RE: MANUF.
DETAIL FOR
ANCHOR
LAYOUT
CONCRETE PAVING,
RE: PLANS
BENCH INSTALL ON CONCRETE
3/4" = 1'-0"
S-FU-45
TRASH RECEPTACLE ON CONCRETE
3/4" = 1'-0"
1/2" ANCHOR BOLT AT
EACH LEG. CUT BOLT 1/16"
PROUD OF NUT AND PEEN
END TO LOCK NUT.
TRASH RECEPTACLE,
RE: PLANS
RE: MANUF.
DETAIL FOR
ANCHOR
LAYOUT
CONCRETE PAVING,
RE: PLANS
S-FU-48
MULCH NOTE:
ALL PLANTING AREA TO RECEIVE CLEAN LONGLEAF PINE STRAW MULCH, 3" DEPTH AFTER
SETTLING, UNLESS OTHERWISE NOTED ON PLANS.
C
C
C
C
C
S
C
C
C
E
EE E
WW
W
C
C
W
C
C
C
E
TR
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
E
S
C
C
EE
E
E
E
E
E E
E
E
W
W
W
W
W
WV
WV
WV
E
S
E
CS SS
S C C
E EE
TV TV
W
W
W
W
W
WW
CO CO
C
C
C C
C
C
EE
W
W
C
E
TR
TRTR
TR TR
W
C
W
C
C
C
C
C
C
C
C
C
C
C
CC
C
C
C
C C
C
C
C
C
C
C
C
C
CCC
C
C
S
S S
S
S
SSS
S
C C
C
C C C
C
C C
C
C
C
C
C
C C
E
E E E
E
E E E E
E
E
E E
E
U
W
W
W W
W
W
W
W
W x
PX
WW
W
W
CCC
C
C
W
W
E
FO
S W
W
S
S
W
W W
S
C
WV
ELEC
VAN
GO
LF
C
AR
T
PA
RK
IN
G
GO
LF
C
AR
T
PA
RK
IN
G
GO
LF
C
AR
T
PA
RK
IN
G
GO
LF
C
AR
T
PA
RK
IN
G
GOLF CART
PARKING
GOLF CART
PARKING
GOLF CART
PARKING
GOLF CART
PARKING
ALT #1
ALT #1
BA
SE
B
ID
9 10 10
7 78
10 10
10 10
9 9
9 9
15 14
10 10
54 4
3 2
24" LIVE OAK
E
E C
E E
E C
C E
Q
Q
Q
Q
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
0 1
MB
F
C
51 21
8 8 8 8 8 8
5 1 51
5 1 5 1
01010101 01010101010101010101010101
010101
C C
C C
C C
C C
C C
C C
C C
C C
C C
5 151
5 1
5 1
0 1
5 1
0 1
515 1
0 1
0 1
0 1
0 1
0 1
5 1
M
B F2
G
PM
PS
I
G
PM
PS
I
G
PM
PS
I
G
PM
PS
I
G
PM
PS
I
G
PM
PS
I
G
PM
PS
I
G
PM
PS
I
G
PM
PS
I
C
R F
R F landscape architecture land planning placemaking
Foley, Alabama P. 251.948.7181 www.was-design.com
Mobile, Alabama P. 251.344.4023
Jackson, Mississippi P. 601.790.0781 Pensacola, Florida P. 850.203.4252
NOT FOR CONSTRUCTION
N O
R T
H
Scale: 1" = 120'
IRRIGATION PLAN1
IRRIGATION GRAPHICS NOTES
IRRIGATION SYSTEM DESIGN GRAPHICS ARE DIAGRAMMATIC IN NATURE, AND
INTENDED TO INDICATE GENERAL LOCATION AND PROXIMITY TO OTHER ELEMENTS OF
THE DRAWING. AS SUCH, MAINLINE AND/OR VALVES ARE OFTEN SHOWN OUTSIDE OF
TRENCH FOR GRAPHIC CLARITY. ALL EQUIPMENT AND PIPE SHALL BE WITHIN
PROPERTY BOUNDARIES UNLESS OTHERWISE NOTED. SLEEVE SIZES TO BE
DETERMINED BY CONTRACTOR UNLESS NOTED ON THE DRAWINGS.
AlabamaSafely.Dig
800-292-8525 #DIG (Cellular) Call
NORTH
E. 22ND AVE
E. 24TH AVE
E.
R D
S T
E.
N D
S T
CANAL ROAD
KEY PLAN
E. 23RD AVE
WATERWAY E. BLVD
E.
N D
S T
E. 25TH AVE
INTRACOASTAL WATERWAY
00 120' 240'
LI202
LI201
LI200
C E W
C
C
TR
C
C
C
C C
C
CC
C
E
S
C E
E
E
E
E
EEE
W
W
W V W V
E
E
W W
S
W V
VAN
GOLF CART
PARKING
GOLF CART
PARKING
GOLF CART
PARKING
GOLF CART
PARKING
GOLF CART
PARKING
GOLF CART
PARKING
GOLF CART
PARKING
GOLF CART
PARKING
AL
T
AL
T
1BASE BID
E EC E E EC C E
Q
Q
Q
Q
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
8 8
0101 8 8 8 8
8 8 8 8 88 888 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8
M
BF
26.111
2"
29.111
2"
2"
2"
24.711
2"
2"
31.211
2"
2"
28.511
2"
2"
20.611
2"
2"
24.011
2"
C
2"
4" 6"
4" 4"
4" 4" 4"
6"
4" 4"
4"
4"
4"
4"
4"
4"
4"4"4"4"
6"
4"4"4"4"
4"
4"
4"
4"
4" 4"
4"
4" 4"
4"
4"
6"
4"
4" 4"
4"
6"
6"
51 51
41.02"
2"
01 01
10.911
2"
4"
4"
4"
4"
4"
6" 4"
6"
4"
CCCCCCCCCCCCC C C C C C
4"4"
21 214" 4"
4"
6"
6"
6"
6"
6"
4"
2"
6"
6"
51 51
4"
4"
4" 4"4"
16.511
2"
6"
2121 21
50GPM
50PSI
50GPM
50PSI
2"
2"
2"
2"
112"
RF
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI
RAIN BIRD 1806-SAM-PRS 15 STRIP SERIES
TURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING.
27 30
RAIN BIRD 1806-SAM-PRS 8 SERIES MPR
TURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING.
46 30
RAIN BIRD 1806-SAM-PRS 10 SERIES MPR
TURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING.
6 30
RAIN BIRD 1806-SAM-PRS 12 SERIES MPR
TURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING.
6 30
RAIN BIRD 1806-SAM-PRS 15 SERIES MPR
TURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING.
8 30
RAIN BIRD 1812-SAM-PRS 15 STRIP SERIES
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
8 30
RAIN BIRD 1812-SAM-PRS 5 SERIES MPR
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
80 30
RAIN BIRD 1812-SAM-PRS 8 SERIES MPR
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
5 30
RAIN BIRD 1812-SAM-PRS 10 SERIES MPR
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
21 30
RAIN BIRD 1812-SAM-PRS 12 SERIES MPR
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
59 30
RAIN BIRD 1812-SAM-PRS 15 SERIES MPR
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
29 30
RAIN BIRD 1806-SAM-PRS-1300AF FLOOD
FLOOD BUBBLER 6.0" POP-UP WITH CHECK VALVE AND
PRESSURE REGULATOR, WITH A PA-80 ADAPTER.
120 10
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI GPM RADIUS
RAIN BIRD 5006-PL-PC-SAM-R-MPR 25
TURF ROTOR, 6IN. POP-UP, PLASTIC RISER, WITH FLOW
SHUT-OFF DEVICE. MATCHED PRECIPITATION ROTOR (MPR
NOZZLE), ARC AND RADIUS AS PER SYMBOL. 25 FT=RED, 30
FT=GREEN, 35FT=BEIGE. WITH SEAL-A-MATIC CHECK
VALVE, AND IN-STEM PRESSURE REGULATOR.
20 35 24'
MANUFACTURER/MODEL/DESCRIPTION
EST CST SSTRCSLCS
E L R C S
FHTQ
8 8 8 8
Q T H F 01 01 01 01
Q TQ FHT
21 21 21 21 21
Q TQ FHT
51 51 51 51 51
EST CST SSTRCSLCS
Q H F
FHTQ
Q T H F
Q TQ FHT
Q TQ FHT
ARC
IRRIGATION SCHEDULE BASE BID
VALVE, AND IN-STEM PRESSURE REGULATOR.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
RAIN BIRD PGA GLOBE 1-1/2"
1IN., 1-1/2IN., 2IN. ELECTRIC REMOTE CONTROL VALVE,
GLOBE. INSTALL RAIN BIRD FD-101TURF DECODER AT
EACH VALVE PER MANUFACTURER'S REQUIREMENTS
RAIN BIRD 33-DRC 3/4"
3/4IN. BRASS QUICK-COUPLING VALVE, WITH
CORROSION-RESISTANT STAINLESS STEEL SPRING,
THERMOPLASTIC RUBBER COVER, DOUBLE TRACK KEY
LUG, AND 2-PIECE BODY.
BALL VALVE
BALL VALVE & VALVE BOX, SIZED TO MATCH PIPE SIZE
RAIN BIRD PGA GLOBE 2"
1IN., 1-1/2IN., 2IN. ELECTRIC MASTER VALVE, GLOBE.
INSTALL RAIN BIRD FD-101TURF DECODER AT EACH VALVE
PER MANUFACTURER'S REQUIREMENTS
APOLLO VALVES 4A107A4F 1-1/2"
DUAL CHECK VALVE BACKFLOW PREVENTER, INLET SIZE
1-1/2IN., UNION END BALL VALVES, SAE TESTCOCKS
RAIN BIRD ESP-LXD-LXMMSS-LXMMSSPED
50 STATION, 2-WIRE DECODER BASED CONTROLLER IN
STAINLESS STEEL, CABINET W/ PEDESTAL. (1) ESP-LXD
50-STATION, INDOOR/OUTDOOR, PLASTIC WALL-MOUNT
ENCLOSURE. INSTALL IN RAIN BIRD LXMMSS-LXMMSSPED
STAINLESS STEEL CABINET W/ PEDESTAL. SYSTEM
REQUIREMENTS: RAIN BIRD FD-XXX-TURF FIELD
DECODERS, PAIGE ELECTRIC CABLE P7072D & RAIN BIRD
WC20 DRY SPLICES ONLY. GROUND SYSTEM W/ (X)
LSP-1TURF SURGE PROTECTION DECODERS IN RAIN BIRD
ROUND VALVE BOXES. INSTALL PER MANUFACTURERS
RECOMMENDATIONS.
RAIN BIRD WR2-RFC
WIRELESS RAIN AND FREEZE SENSOR COMBO, INCLUDES 1
RECEIVER AND 1 RAIN/FREEZE SENSOR TRANSMITTER.
RAIN BIRD FS-200-B
2IN. FLOW SENSOR, BRASS MODEL. SUGGESTED
OPERATING RANGE 10 GPM TO 100 GPM. SIZE FOR FLOW
NOT ACCORDING TO PIPE SIZE. RAIN BIRD COMPATIBLE
CONTROLLERS: ESP-LXIVM(P) | LXD | LXME2(P) | ME3, OR
CONTROLLERS ACCEPTING CUSTOM K-FACTOR AND
OFFSET. INSTALL IN RAIN BIRD VALVE BOX.
CAP FOR FUTURE USE
CAP AT THE MAINLINE OR LATERAL LINE FOR FUTURE USE.
THE PRESSURE AND FLOW PROVIDED TO THAT LOCATION
ARE INDICATED NEXT TO THE CAP SYMBOL.
WATER METER 1-1/2"
BASIS OF DESIGN: 60 GPM @ 60 PSI. CONTRACTOR TO
VERIFY
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 1"
ONLY LATERAL TRANSITION PIPE SIZES 1 1/4" AND ABOVE
ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1"
IN SIZE.
5,366 LF
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 1 1/2"
ONLY LATERAL TRANSITION PIPE SIZES 1 1/4" AND ABOVE
ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1"
IN SIZE.
565.8 LF
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 1 1/2" 11.8 LF
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 2" 935.2 LF
PIPE SLEEVE: PVC SCHEDULE 40 4" 706.6 LF
PIPE SLEEVE: PVC SCHEDULE 40 6" 227.1 LF
BF
C
RF
X X
M
Valve Number
Valve Flow
Valve Size
Valve Callout
00 20' 40' landscape architecture land planning placemaking
Foley, Alabama P. 251.948.7181 www.was-design.com
Mobile, Alabama P. 251.344.4023
Jackson, Mississippi P. 601.790.0781 Pensacola, Florida P. 850.203.4252
NOT FOR CONSTRUCTION
N O
R T
H
Scale: 1" = 20'
IRRIGATION PLAN ENLARGEMENT1
IRRIGATION GRAPHICS NOTES
IRRIGATION SYSTEM DESIGN GRAPHICS ARE
DIAGRAMMATIC IN NATURE, AND INTENDED TO INDICATE
GENERAL LOCATION AND PROXIMITY TO OTHER ELEMENTS
OF THE DRAWING. AS SUCH, MAINLINE AND/OR VALVES
ARE OFTEN SHOWN OUTSIDE OF TRENCH FOR GRAPHIC
CLARITY. ALL EQUIPMENT AND PIPE SHALL BE WITHIN
PROPERTY BOUNDARIES UNLESS OTHERWISE NOTED.
SLEEVE SIZES TO BE DETERMINED BY CONTRACTOR
UNLESS NOTED ON THE DRAWINGS.
AlabamaSafely.Dig
800-292-8525 #DIG (Cellular) Call
PROPOSED WATER
METER APPROXIMATE
LOCATION. METER
SHOWN IN DIFFERENT
LOCATION FOR
GRAPHIC CLARITY.
NORTH
E. 22ND AVE
E. 24TH AVE
E.
R D
S T
E.
N D
S T
CANAL ROAD
KEY PLAN
E. 23RD AVE
WATERWAY E. BLVD
E.
N D
S T
E. 25TH AVE
INTRACOASTAL WATERWAY
QUANTITY TAKEOFF DISCLAIMER:
QUANTITIES NOTED ON PLANS ARE OFFERED AS A CONVENIENCE
TO THE CONTRACTOR FOR BID PURPOSES ONLY. CONTRACTOR
SHALL VERIFY ALL QUANTITIES AND REPORT ANY DISCREPANCIES
TO THE LANDSCAPE ARCHITECT.
BID ALTERNATE NOTE:
REFER TO LP500 FOR BID ALTERNATE SCHEDULE
C
C
E E
E
C
C
C
C
C S
S
C
C
C
C
C
C
S
E x x x x x x x
C
ELEC
11 11
10 10
" LIV
E O
A K
" PA
LM
" W A
TER
O A K
" PA
LM
" LIV
E O
A K
21 2121 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21
2121 212121212121212121212121212121212121212121212121
8 8 8 8 8 88 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 88 8 8 8 8 8 8 8 8 8
8 8 8 8 8 8 8 8 8 8
51 51 51
51 51 5151
888 88888888888888888888
8888888888888888888888888
11.111
2"
23.511
2"
15.211
2"
21.611
2"
2"
21 21
4"
17.011
2"
32.511
2"
2"
32.511 2"
28.111
2"
2"
2"
2"
4"
2" 21 21
4" 6"
4" 4"
24.411
2"
4"
2"
20.311
2"
6"
50GPM
50PSI
50GPM
50PSI
50GPM
50PSI
2"
4" 4" 21 51
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI
RAIN BIRD 1806-SAM-PRS 8 SERIES MPR
TURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING.
95 30
RAIN BIRD 1806-SAM-PRS 12 SERIES MPR
TURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING.
65 30
RAIN BIRD 1806-SAM-PRS 15 SERIES MPR
TURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING.
13 30
RAIN BIRD 1812-SAM-PRS 15 STRIP SERIES
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
2 30
RAIN BIRD 1812-SAM-PRS 5 SERIES MPR
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
68 30
RAIN BIRD 1812-SAM-PRS 12 SERIES MPR
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
30 30
RAIN BIRD 1812-SAM-PRS 15 SERIES MPR
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
39 30
RAIN BIRD 1806-SAM-PRS-1300AF FLOOD
FLOOD BUBBLER 6.0" POP-UP WITH CHECK VALVE AND
PRESSURE REGULATOR, WITH A PA-80 ADAPTER.
108 10
FHTQ
8 8 8 8
Q TQ FHT
21 21 21 21 21
Q TQ FHT
51 51 51 51 51
EST CST SSTRCSLCS
Q H F
Q TQ FHT
Q TQ FHT
IRRIGATION SCHEDULE 23RD TO 24TH
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
RAIN BIRD PGA GLOBE 1-1/2"
1IN., 1-1/2IN., 2IN. ELECTRIC REMOTE CONTROL VALVE,
GLOBE. INSTALL RAIN BIRD FD-101TURF DECODER AT
EACH VALVE PER MANUFACTURER'S REQUIREMENTS
BALL VALVE
BALL VALVE & VALVE BOX, SIZED TO MATCH PIPE SIZE
CAP FOR FUTURE USE
CAP AT THE MAINLINE OR LATERAL LINE FOR FUTURE USE.
THE PRESSURE AND FLOW PROVIDED TO THAT LOCATION
ARE INDICATED NEXT TO THE CAP SYMBOL.
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 1"
ONLY LATERAL TRANSITION PIPE SIZES 1 1/4" AND ABOVE
ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1"
IN SIZE.
4,643 LF
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 1 1/2"
ONLY LATERAL TRANSITION PIPE SIZES 1 1/4" AND ABOVE
ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1"
IN SIZE.
218.9 LF
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 2" 1,125 LF
PIPE SLEEVE: PVC SCHEDULE 40 4" 89.0 LF
PIPE SLEEVE: PVC SCHEDULE 40 6" 50.3 LF
X X
Valve Number
Valve Flow
Valve Size
Valve Callout
00 20' 40' landscape architecture land planning placemaking
Foley, Alabama P. 251.948.7181 www.was-design.com
Mobile, Alabama P. 251.344.4023
Jackson, Mississippi P. 601.790.0781 Pensacola, Florida P. 850.203.4252
NOT FOR CONSTRUCTION
IRRIGATION GRAPHICS NOTES:
IRRIGATION SYSTEM DESIGN GRAPHICS ARE DIAGRAMMATIC IN NATURE, AND
INTENDED TO INDICATE GENERAL LOCATION AND PROXIMITY TO OTHER ELEMENTS OF
THE DRAWING. AS SUCH, MAINLINE AND/OR VALVES ARE OFTEN SHOWN OUTSIDE OF
TRENCH FOR GRAPHIC CLARITY. ALL EQUIPMENT AND PIPE SHALL BE WITHIN
PROPERTY BOUNDARIES UNLESS OTHERWISE NOTED. SLEEVE SIZES TO BE
DETERMINED BY CONTRACTOR UNLESS NOTED ON THE DRAWINGS.
NORTH
E. 22ND AVE
E. 24TH AVE
E.
R D
S T
E.
N D
S T
CANAL ROAD
KEY PLAN
E. 23RD AVE
WATERWAY E. BLVD
E.
N D
S T
E. 25TH AVE
INTRACOASTAL WATERWAY
N O
R T
H
Scale: 1" = 20'
IRRIGATION PLAN ENLARGEMENT1
QUANTITY TAKEOFF DISCLAIMER:
QUANTITIES NOTED ON PLANS ARE OFFERED AS A CONVENIENCE TO THE
CONTRACTOR FOR BID PURPOSES ONLY. CONTRACTOR SHALL VERIFY ALL QUANTITIES
AND REPORT ANY DISCREPANCIES TO THE LANDSCAPE ARCHITECT.
APPX. LOCATION OF EXISTING SLEEVING, TYP. (2) 4"
PVC PIPES AT EACH LOCATION SHOWN. REBAR AT
EACH LOCATION TO BE DETECTABLE BY METAL
DETECTOR. CONTRACTOR TO VERIFY.
IRRIGATION SLEEVING NOTES:
APPROXIMATE LOCATIONS OF EXISTING SLEEVES ARE SHOWN ON THE PLANS.
CONTRACTOR SHALL VERIFY ALL EXISTING SLEEVES IN THE FIELD. PROVIDE ALL
ADDITIONAL SLEEVES REQUIRED FOR A COMPLETE IRRIGATION INSTALLATION. ALL
NEW SLEEVES INSTALLED BENEATH EXISTING PAVEMENT, SIDEWALKS, CURB AND
GUTTER, OR OTHER IMPROVEMENTS SHALL BE INSTALLED BY HORIZONTAL BORING.
CUTTING AND PATCHING OF EXISTING IMPROVEMENTS WILL NOT BE PERMITTED
UNLESS SPECIFICALLY APPROVED BY THE OWNER.
AlabamaSafely.Dig
800-292-8525 #DIG (Cellular) Call
BASE DATA NOTES:
SURVEY FOR E. 2ND STREET BETWEEN 23RD ST. & 24 ST. PROVIDED BY WEYGAND
WILSON DATED 05.08.2026
E 2
TH
A
V E
' - R /W
W A
TER
W A
Y EA
S T B
O U
LEV
A R D
' - R /W
E 2
TH
A
V E
' - R /W
E 2
TH
A
V E
' - R /W
212121212121212121212121212121212121212121212121
212121212121212121212121212121212121212121212121
0101 01 01
0101 01 01
01 01
21 21 21
21 21
010101010101 01 01 01 0101 010101 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01
01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01
2121 21
5151 21
51 51
21 21
21 21
M2
BF2
33.211
2"
2"
30.611
2"
242"
26.411
2"
29.111
2"
35.111
2"
32.511
2"
29.211
2"
302"
33.111
2"
35.82"
272"
12.211
2"
2"
402"
2"
50GPM
50PSI
50GPM
50PSI
2"
50GPM
50PSI
45GPM
45PSI
6"
6"
6"6"4" 4"
4"
4"
4"
6"4" 4" 4"
6"
6"
2"112"
C2RF
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI
RAIN BIRD 1806-SAM-PRS 5 SERIES MPR
TURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING.
7 30
RAIN BIRD 1806-SAM-PRS 10 SERIES MPR
TURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING.
73 30
RAIN BIRD 1806-SAM-PRS 12 SERIES MPR
TURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING.
80 30
RAIN BIRD 1806-SAM-PRS 15 SERIES MPR
TURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING.
13 30
RAIN BIRD 1812-SAM-PRS 15 STRIP SERIES
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
1 30
RAIN BIRD 1812-SAM-PRS 5 SERIES MPR
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
68 30
RAIN BIRD 1812-SAM-PRS 8 SERIES MPR
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
2 30
RAIN BIRD 1812-SAM-PRS 10 SERIES MPR
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
9 30
RAIN BIRD 1812-SAM-PRS 12 SERIES MPR
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
64 30
RAIN BIRD 1812-SAM-PRS 15 SERIES MPR
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
37 30
RAIN BIRD 1806-SAM-PRS-1300AF FLOOD
FLOOD BUBBLER 6.0" POP-UP WITH CHECK VALVE AND
PRESSURE REGULATOR, WITH A PA-80 ADAPTER.
129 10
Q H F 5 5 5
Q T H F 01 01 01 01
Q TQ FHT
21 21 21 21 21
Q TQ FHT
51 51 51 51 51
EST CST SSTRCSLCS
Q H F
FHTQ
Q T H F
Q TQ FHT
Q TQ FHT
IRRIGATION SCHEDULE 25TH TO WATERWAY E
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
RAIN BIRD PGA GLOBE 1-1/2"
1IN., 1-1/2IN., 2IN. ELECTRIC REMOTE CONTROL VALVE,
GLOBE. INSTALL RAIN BIRD FD-101TURF DECODER AT
EACH VALVE PER MANUFACTURER'S REQUIREMENTS
RAIN BIRD PGA GLOBE 2"
1IN., 1-1/2IN., 2IN. ELECTRIC REMOTE CONTROL VALVE,
GLOBE. INSTALL RAIN BIRD FD-101TURF DECODER AT
EACH VALVE PER MANUFACTURER'S REQUIREMENTS
RAIN BIRD 33-DRC 3/4"
3/4IN. BRASS QUICK-COUPLING VALVE, WITH
CORROSION-RESISTANT STAINLESS STEEL SPRING,
THERMOPLASTIC RUBBER COVER, DOUBLE TRACK KEY
LUG, AND 2-PIECE BODY.
BALL VALVE
BALL VALVE & VALVE BOX, SIZED TO MATCH PIPE SIZE
RAIN BIRD PGA GLOBE 2"
1IN., 1-1/2IN., 2IN. ELECTRIC MASTER VALVE, GLOBE.
INSTALL RAIN BIRD FD-101TURF DECODER AT EACH VALVE
PER MANUFACTURER'S REQUIREMENTS
APOLLO VALVES 4A107A4F 1-1/2"
DUAL CHECK VALVE BACKFLOW PREVENTER, INLET SIZE
1-1/2IN., UNION END BALL VALVES, SAE TESTCOCKS
RAIN BIRD ESP-LXD-LXMMSS-LXMMSSPED
50 STATION, 2-WIRE DECODER BASED CONTROLLER IN
STAINLESS STEEL, CABINET W/ PEDESTAL. (1) ESP-LXD
50-STATION, INDOOR/OUTDOOR, PLASTIC WALL-MOUNT
ENCLOSURE. INSTALL IN RAIN BIRD LXMMSS-LXMMSSPED
STAINLESS STEEL CABINET W/ PEDESTAL. SYSTEM
REQUIREMENTS: RAIN BIRD FD-XXX-TURF FIELD
DECODERS, PAIGE ELECTRIC CABLE P7072D & RAIN BIRD
WC20 DRY SPLICES ONLY. GROUND SYSTEM W/ (X)
LSP-1TURF SURGE PROTECTION DECODERS IN RAIN BIRD
ROUND VALVE BOXES. INSTALL PER MANUFACTURERS
RECOMMENDATIONS.
RAIN BIRD WR2-RFC
WIRELESS RAIN AND FREEZE SENSOR COMBO, INCLUDES 1
RECEIVER AND 1 RAIN/FREEZE SENSOR TRANSMITTER.
RAIN BIRD FS-200-B
2IN. FLOW SENSOR, BRASS MODEL. SUGGESTED
OPERATING RANGE 10 GPM TO 100 GPM. SIZE FOR FLOW
NOT ACCORDING TO PIPE SIZE. RAIN BIRD COMPATIBLE
CONTROLLERS: ESP-LXIVM(P) | LXD | LXME2(P) | ME3, OR
CONTROLLERS ACCEPTING CUSTOM K-FACTOR AND
OFFSET. INSTALL IN RAIN BIRD VALVE BOX.
CAP FOR FUTURE USE
CAP AT THE MAINLINE OR LATERAL LINE FOR FUTURE USE.
THE PRESSURE AND FLOW PROVIDED TO THAT LOCATION
ARE INDICATED NEXT TO THE CAP SYMBOL.
WATER METER 1-1/2"
BASIS OF DESIGN: 60 GPM @ 60 PSI. CONTRACTOR TO
VERIFY
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 1"
ONLY LATERAL TRANSITION PIPE SIZES 1 1/4" AND ABOVE
ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1"
IN SIZE.
5,692 LF
BF2
C2
RF
X X
M2
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 1 1/2"
ONLY LATERAL TRANSITION PIPE SIZES 1 1/4" AND ABOVE
ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1"
IN SIZE.
537.3 LF
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 2"
ONLY LATERAL TRANSITION PIPE SIZES 1 1/4" AND ABOVE
ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1"
IN SIZE.
149.5 LF
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 1 1/2" 8.3 LF
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 2" 1,361 LF
PIPE SLEEVE: PVC SCHEDULE 40 4" 100.7 LF
PIPE SLEEVE: PVC SCHEDULE 40 6" 147.3 LF
Valve Number
Valve Flow
Valve Size
Valve Callout
00 20' 40' landscape architecture land planning placemaking
Foley, Alabama P. 251.948.7181 www.was-design.com
Mobile, Alabama P. 251.344.4023
Jackson, Mississippi P. 601.790.0781 Pensacola, Florida P. 850.203.4252
NOT FOR CONSTRUCTION
NORTH
E. 22ND AVE
E. 24TH AVE
E.
R D
S T
E.
N D
S T
CANAL ROAD
KEY PLAN
E. 23RD AVE
WATERWAY E. BLVD
E.
N D
S T
E. 25TH AVE
INTRACOASTAL WATERWAY
N O
R T
H
Scale: 1" = 20'
IRRIGATION PLAN ENLARGEMENT1
APPX. LOCATION OF EXISTING SLEEVING, TYP. (2) 4"
PVC PIPES AT EACH LOCATION SHOWN. REBAR AT
EACH LOCATION TO BE DETECTABLE BY METAL
DETECTOR. CONTRACTOR TO VERIFY.
IRRIGATION GRAPHICS NOTES:
IRRIGATION SYSTEM DESIGN GRAPHICS ARE DIAGRAMMATIC IN NATURE, AND
INTENDED TO INDICATE GENERAL LOCATION AND PROXIMITY TO OTHER ELEMENTS OF
THE DRAWING. AS SUCH, MAINLINE AND/OR VALVES ARE OFTEN SHOWN OUTSIDE OF
TRENCH FOR GRAPHIC CLARITY. ALL EQUIPMENT AND PIPE SHALL BE WITHIN
PROPERTY BOUNDARIES UNLESS OTHERWISE NOTED. SLEEVE SIZES TO BE
DETERMINED BY CONTRACTOR UNLESS NOTED ON THE DRAWINGS.
QUANTITY TAKEOFF DISCLAIMER:
QUANTITIES NOTED ON PLANS ARE OFFERED AS A CONVENIENCE TO THE
CONTRACTOR FOR BID PURPOSES ONLY. CONTRACTOR SHALL VERIFY ALL QUANTITIES
AND REPORT ANY DISCREPANCIES TO THE LANDSCAPE ARCHITECT.
IRRIGATION SLEEVING NOTES:
APPROXIMATE LOCATIONS OF EXISTING SLEEVES ARE SHOWN ON THE PLANS.
CONTRACTOR SHALL VERIFY ALL EXISTING SLEEVES IN THE FIELD. PROVIDE ALL
ADDITIONAL SLEEVES REQUIRED FOR A COMPLETE IRRIGATION INSTALLATION. ALL
NEW SLEEVES INSTALLED BENEATH EXISTING PAVEMENT, SIDEWALKS, CURB AND
GUTTER, OR OTHER IMPROVEMENTS SHALL BE INSTALLED BY HORIZONTAL BORING.
CUTTING AND PATCHING OF EXISTING IMPROVEMENTS WILL NOT BE PERMITTED
UNLESS SPECIFICALLY APPROVED BY THE OWNER.
AlabamaSafely.Dig
800-292-8525 #DIG (Cellular) Call
APPROXIMATE LOCATION OF EXISTING
WATER METER FOR IRRIGATION SYSTEM.
CONTRACTOR TO VERIFY.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI
RAIN BIRD 1806-SAM-PRS 8 SERIES MPR
TURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING.
9 30
RAIN BIRD 1806-SAM-PRS 10 SERIES MPR
TURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING.
25 30
RAIN BIRD 1806-SAM-PRS 12 SERIES MPR
TURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING.
3 30
RAIN BIRD 1806-SAM-PRS 15 SERIES MPR
TURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING.
10 30
RAIN BIRD 1812-SAM-PRS 5 SERIES MPR
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
16 30
RAIN BIRD 1812-SAM-PRS 10 SERIES MPR
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
2 30
RAIN BIRD 1812-SAM-PRS 12 SERIES MPR
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
3 30
RAIN BIRD 1812-SAM-PRS 15 SERIES MPR
SHRUB SPRAY 12.0" POP-UP SPRINKLER WITH CO-MOLDED
WIPER SEAL. 1/2" NPT FEMALE THREADED INLET. WITH
SEAL-A-MATIC CHECK VALVE, AND PRESSURE
REGULATING DEVICE.
5 30
RAIN BIRD 1806-SAM-PRS-1300AF FLOOD
FLOOD BUBBLER 6.0" POP-UP WITH CHECK VALVE AND
PRESSURE REGULATOR, WITH A PA-80 ADAPTER.
18 10
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
RAIN BIRD PGA GLOBE 1-1/2"
1IN., 1-1/2IN., 2IN. ELECTRIC REMOTE CONTROL VALVE,
GLOBE. INSTALL RAIN BIRD FD-101TURF DECODER AT
EACH VALVE PER MANUFACTURER'S REQUIREMENTS
RAIN BIRD PGA GLOBE 2"
1IN., 1-1/2IN., 2IN. ELECTRIC REMOTE CONTROL VALVE,
GLOBE. INSTALL RAIN BIRD FD-101TURF DECODER AT
EACH VALVE PER MANUFACTURER'S REQUIREMENTS
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 1"
ONLY LATERAL TRANSITION PIPE SIZES 1 1/4" AND ABOVE
ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1"
IN SIZE.
1,201 LF
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 1 1/2"
ONLY LATERAL TRANSITION PIPE SIZES 1 1/4" AND ABOVE
ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1"
IN SIZE.
73.5 LF
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 2"
ONLY LATERAL TRANSITION PIPE SIZES 1 1/4" AND ABOVE
ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1"
IN SIZE.
9.6 LF
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 2" 202.0 LF
PIPE SLEEVE: PVC SCHEDULE 40 4" 89.9 LF
PIPE SLEEVE: PVC SCHEDULE 40 6" 64.6 LF
FHTQ
8 8 8 8
Q T H F 01 01 01 01
Q TQ FHT
21 21 21 21 21
Q TQ FHT
51 51 51 51 51
Q H F
Q T H F
Q TQ FHT
Q TQ FHT
Valve Number
Valve Flow
Valve Size
Valve Callout
IRRIGATION SCHEDULE BID ALTERNATE #1
landscape architecture land planning placemaking
Foley, Alabama P. 251.948.7181 www.was-design.com
Mobile, Alabama P. 251.344.4023
Jackson, Mississippi P. 601.790.0781 Pensacola, Florida P. 850.203.4252
NOT FOR CONSTRUCTION
3" = 1'-0"
TURF SPRAY FLEX ASSEMBLY1
328403.13-02 3" = 1'-0"
TURF ROTOR MARLEX ASSEMBLY2
328403.16-01 3" = 12"
SHRUB SPRAY HIGHPOP W/ FLEX ASSEMBLY3
328403.29-01
1 1/2" = 1'-0"
TRUE UNION BALL ISOLATION VALVE5
328406.33-04
SLEEVING DETAIL
1/2" = 1'-0"
1' -0
VA
R
IE
S 1'
-0
M
IN
PVC SLEEVE
NOTE:
INSTALLER OF SLEEVES SHALL BE RESPONSIBLE TO
LOCATE SLEEVES IF NOT PROPERLY INSTALLED.
1'-6"
328409.76-05
3" = 1'-0"
POPUP BUBBLER AT PLANT PIT
FX-IR-FX-HEAD-16
QUANTITY TAKEOFF DISCLAIMER:
QUANTITIES NOTED ON PLANS ARE OFFERED AS A CONVENIENCE TO THE
CONTRACTOR FOR BID PURPOSES ONLY. CONTRACTOR SHALL VERIFY ALL QUANTITIES
AND REPORT ANY DISCREPANCIES TO THE LANDSCAPE ARCHITECT.
1" = 1'-0"
PEDESTAL MOUNT CONTROLLER8
328409.16-03
20"X14" JUMBO PLASTIC
VALVE BOX.
2" ABOVE GRADE AT
SHRUBS.
" B
EL
O
W G
R
AD
E.
OUTLET PIPE SAME SIZE AS
VALVE, 24" MIN. LENGTH TO
FIRST FITTING.
PVC UNION W/ SHORT
NIPPLES.
SET BOX FLUSH AT
TURF.
20"X14" JUMBO PLASTIC
VALVE BOX.
2" ABOVE GRADE AT
SHRUBS.
" B
EL
O
W G
R
AD
E.
2" WIRE CLOTH GOPHER
SCREEN, WRAP UP SIDES.
TWO 6X2X16 CONCRETE BLOCK CAPS, ONE ON
EACH SIDE OF THE BOX.
45° DOWN AS REQ. TO
LATERAL PIPE DEPTH.
OUTLET PIPE SAME SIZE AS
VALVE, 24" MIN. LENGTH TO
FIRST FITTING.
PVC UNION W/ SHORT
NIPPLES.
SET BOX FLUSH AT
TURF.
DUAL CHECK VALVE IN BOX
1/2" = 1'-0" 328409.46-06
RAIN BIRD MASTER VALVE AND FS SERIES FLOW SENSOR
3" = 1'-0"
10X DIAMETER OF PIPE 5X DIAMETER OF PIPE
RAIN BIRD MASTER VALVE, SEE LEGEND
FOR MODEL
36" LENGTH OF COILED CONTROL WIRE2
3.0-INCH MIN. DEPTH OF 3/4-INCH WASHED
GRAVEL
BRICK (1 OF 4), IF APPLICABLE4
RAIN BIRD VB SERIES VALVE BOX W/ LID5
FINISH GRADE6
RAIN BIRD FS SERIES FLOW SENSOR, SEE
LEGEND FOR MODEL
DOUBLE-STRAP SADDLE8
REFERENCE MANUAL FOR WIRING
INSTALLATION INSTRUCTIONS
10 PE-CABLE TO CONTROLLER
FX-IRRG-RAIN-FLOW-03
SOIL
SEPARATOR
FABRIC,
WRAP UP
SIDES OF
VALVE BOX
AS SHOWN
INLET PIPE, SAME SIZE AS
OUTLET PIPE
CONC. BRICK SUPPORT, TWO
ON EACH SIDE
TWO-WIRE CABLE, ALLOW 3'
EXTRA CABLE LENGTH
PLASTIC I.D. TAG AT EACH VALVE
3M DBR/Y CONNECTORS
DECODER, INSTALL PER
MANUFACTURER'S SPECS
ELEC. REMOTE CONTROL VALVE-2 WIRE
1 1/2" = 1'-0"
328406.13-08 land planning placemaking
Foley, Alabama P. 251.948.7181 www.was-design.com
Mobile, Alabama P. 251.344.4023
Jackson, Mississippi P. 601.790.0781 Pensacola, Florida P. 850.203.4252
NOT FOR CONSTRUCTION
GROUNDING NOTES:
PROVIDE A COMPLETE GROUNDING AND SURGE PROTECTION SYSTEM FOR THE TWO-WIRE DECODER IRRIGATION SYSTEM IN ACCORDANCE WITH THE LATEST RAIN BIRD GROUNDING SYSTEM RECOMMENDATIONS GUIDE AND ESP-LXD DESIGN GUIDE. CONTRACTOR SHALL FURNISH ALL GROUNDING RODS, GROUNDING PLATES, SURGE PROTECTION DEVICES, GROUNDING WIRE, EXOTHERMIC WELDS OR LISTED CONNECTORS, TESTING, AND ALL
ACCESSORIES NECESSARY FOR A FULLY FUNCTIONAL INSTALLATION.
CONTROLLER GROUNDING GRID
1" = 5'
10'-0"
8'-0"
24'-0"
12"
NOTES:
1. GROUND PLATE SHALL BE
INSTALLED 30" (IN.) BELOW GRADE.
2. ENCASE GROUND PLATE IN 100
LBS. OF EARTH CONTACT
MATERIAL - 50 LBS. BELOW PLATE
AND 50 LBS. ABOVE PLATE.
SPREAD CONTACT MATERIAL
EVENLY.
3. NO OTHER WIRES OR CABLES
SHALL BE INSTALLED WITHIN THE
SPHERE OF INFLUENCE.
11' MIN.
CONTROLLER1
4" x 96" x .0625" GROUND PLATE
IN EARTH CONTACT MATERIAL
ELECTRODE SPHERE OF
INFLUENCE (10' RADIUS)
UL LISTED 5/8" x 10' COPPER
CLAD GROUND ROD WITH
CADWELD CONNECTOR
#6 AWG SOLID BARE COPPER WIRE5
FX-IRRG-RAIN-GRND-01
CONTROLLER GROUNDING GRID SIDE VIEW
3" = 1'-0"
" M
IN
" M
IN
RAIN BIRD CONTROLLER1
SOLID BARE COPPER WIRE (10 AWG).
FROM GROUNDING ROD TO CONTROLLER.
MAKE WIRE AS SHORT AND STRAIGHT AS
POSSIBLE.
1-1/2" PLASTIC SWEEP, 90 DEGREE BEND3
COVER GROUNDING ROD WITH 10-INCH
ROUND VALVE BOX AS SHOWN
5/8-INCH x 10 FT. COPPER CLAD
GROUNDING ROD OR GROUNDING PLATE.
INSTALL RODS IN SOUL IN A TRIANGULAR
PATTERN SPACED A MINIMUM OF 16 FT.
APART FROM EACH OTHER. GROUNDING
GRID TO HAVE A RESISTANCE OF TEN (10)
OHMS OR LESS
BARE COPPER WIRE (#6 AWG. MIN.)
BETWEEN GROUNDING ROD AND
GROUNDING PLATE.
CADWELD CONNECTION7
COPPER GROUNDING PLATE8
GROUND ENHANCEMENT MATERIAL
( IF APPLICABLE)9
FINISH GRADE10
FX-IRRG-RAIN-GRND-02
SURGE PROTECTOR W/ GROUNDING ROD
1 1/2" = 1'-0"
NOTES:
1. INSTALL SURGE PROTECTOR ON ITS OWN OR A VALVE IN THE SAME VALVE BOX.
2. NO OTHER WIRES OR CABLES SHALL BE INSTALLED WITHIN THE SPHERE OF INFLUENCE.
3. INSTALL THE CONNECTING WIRE IN AS STRAIGHT A LINE AS POSSIBLE. IF YOU MUST MAKE A TURN OR BEND
IN THE WIRE, MAKE THE TURN IN A SWEEPING CURVE WITH A MAXIMUM RADIUS OF EIGHT INCHES AND
MINIMUM INCLUDED ANGLE OF 90°.
4. TO MINIMIZE RESISTANCE, THE COPPER WIRE MUST BE PRE-WELDED TO THE GROUNDING RODS/PLATES, OR WELDED TO THE RODS/PLATES USING AN EXOTHERMIC WELDING PROCESS AT THE SITE.
5. MAKE SURE ALL WELDS ARE SECURE BEFORE BURYING THE GROUNDING RODS. RODS AND PLATES WITH
WELDED JOINTS DO NOT NEED PERIODIC VISUAL INSPECTION AND CAN BE FULLY BURIED.
8' MIN.
" M
IN
3 4
RAIN BIRD VALVE BOX 6" ROUND1
SURGE PROTECTOR, SEE LEGEND2
TWO-WIRE MAXI-WIRE PATH3
#6 AWG OR LARGER SOLID BARE COPPER WIRE4
COPPER CLAD GROUNDNG ROD (5/8" x 8')5
FINISH GRADE6
COPPER WIRE7
GROUND ENHANCEMENT, IF APPLICABLE8
CADWELD CONNCECTION9
FX-IRRG-RAIN-GRND-03
l…
This is the start of the file's text. The full file is on GovTribe.