FireSuppression_Elizabeth's_Campus.xlsx

XLSX spreadsheet 33 KB Posted

Attached to
Operation & Maintenance and Elevator Services
Solicitation number
GS-11-P-16-YE-D-7001
Issued by

About this file

Inventory List

View the file

Other files

File Type Posted
Amendment_A010.pdf PDF
RFP_Rev.5.pdf PDF
Amendment_A010 _Correction_Sheet.docx DOCX document
Amendment_A009.pdf PDF
Amendment_A008.pdf PDF
EGS_IBEW_Local_26_CBA_Multiple_Sites_(eff_7-1-13_thru_6-30-16).pdf PDF
Existing_CBA_Local_99.pdf PDF
Amendment_A007_Questions_Clarification.pdf PDF
Amendment_A007.pdf PDF
Section_L.pdf PDF
Amendment__A006.pdf PDF
Amendment_A005.pdf PDF
Revised_Answers_previously_submitted_in_Amendment_A004.docx DOCX document
USCG_HQ_DOC_Garage_CUP_Elevator_Phones_Permanent_List_121313_(1).xlsx XLSX spreadsheet
RFP_Questions_for_O M_Site_Visit_54-100.pdf PDF
ARB_Elevators_Temporary_ _Permanent_122313_(1).xlsx XLSX spreadsheet
Wage_Determination.pdf PDF
RFP_Rev.4.pdf PDF
Safety_and_Health_Doc.rtf RTF text file
GSA_3620_non-GSA_employee_personal_injury.pdf PDF
RFP_Questions_for_O M_Site_Walk_Questions_1-53.docx.pdf PDF
Maximo_Tickets_Per_Request.xlsx XLSX spreadsheet
GSA_3592_Unhealthy_Unsafe_Working_Conditions.pdf PDF
Amendment_A005.pdf PDF
GSA_3623_Supervisor's_Supplemental_Report_of_GSA_Employee_Injury-Illness.pdf PDF
Amendment_A004.pdf PDF
Amendment_A003.pdf PDF
RFP_Rev.3.pdf PDF
Bldg_List.pdf PDF
RFP_Rev.2.pdf PDF
Site_Visit_Location_Instructions.docx DOCX document
Amendment_A002.pdf PDF
Revised_RFP.pdf PDF
SF1449.pdf PDF
Amendment_A001.pdf PDF
SE_Water_Features.pdf PDF
ST_ELIZ_INV.pdf PDF
Fire_Suppression.pdf PDF
SE_BACKFLOW.pdf PDF
INVERTER_DATA.pdf PDF
RFP.docx DOCX document
2016_New_Consolidated_Headquarters_Campus_Visit_and_Badge_Request_Form.xlsx XLSX spreadsheet
SE_Kitchen_INV.pdf PDF
Show all 43

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USCG

United States Coast Guard - Headquarters Building (HQ) Parking Garage (PG) & Central Utility Plant (CUP)
Zone ControlsCheck ValvesBackflow PreventerPRV'sDry Pipe ValvesOS&Y's w/ TampersFDC's & Test HeadersFHV'sButterfly ValvesAir CompressorFlow Switches
NumberZone ServingSizeLocationNumberSizeLocationNumberSizeLocationNumberSizeLocationNumberSizeLocationNumberSizeLocationNumberSizeLocationNumberSizeLocationNumberSizeLocationNumberSizeLocationNumberSizeLocation
11A4"HQ LL9 ST-118"CUP LL1110"CUP110"CUP LL114"HQ LL6 ST-7 - Z20210"CUP LL116-WayHQ LL722-1/2"ST-1 LL9-816"PG-P4 Valve Rm1HQ LL6 ST-716"HQ ST-7 Standpipe
113"HQ LL9 ST-216"CUP LL116"PG-P4 Valve Rm16"PG-P4 Valve RM104"PG-P4 Valve Rm18"CUP LL116-WayHQ LL632-1/2"ST-2 LL9-726"PG-P6 Valve Rm1PG-P4 Valve Rm154"All HQ Standpipes
124"HQ LL9 ST-326"PG-P6 Valve Rm104"PG-P6 Valve Rm16"PG-P6 Valve Rm16-WayHQ LL542-1/2"ST-3 LL9-632"HQ LL6 Z22A1PG-P6 Valve Rm41-1/4"HQ Elev. Mach Rms
134"HQ LL9 ST-416"PG-P4 Valve Rm26"PG-P4 Valve RM16-WayHQ LL442-1/2"ST-4 LL9-641-1/4"HQ Elev. Mach Rms84"PG Standpipes
144"HQ LL9 ST-816"PG FDC84"PG Standpipes16-WayHQ LL162-1/2"ST-5 LL9-4
154"HQ LL8 ST-168"CUP FDC/HQ FDCs14"HQ - ST-814-WayPG32-1/2"ST-6 LL5-3
164"HQ LL8 ST-354"HQ FHV Risers16-WayCUP62-1/2"ST-7 LL6-1
173"HQ LL8 ST-5154"All HQ Standpipes14-Way TestPG72-1/2"ST-8 LL9-3
193"HQ LL8 ST-1216"HQ ST-7 Standpipe16-Way TestCUP52-1/2"ST-9 LL8-4
184"HQ LL8 ST-1082-1/2"ST-10 LL8-1
1104"HQ LL8 ST-882-1/2"ST-11 LL6-2nd
1113"HQ LL7 ST-2112-1/2"ST-12 LL9-2nd
1133"HQ LL7 ST-552-1/2"ST-13 LL4-Grd
1123"HQ LL7 ST-1432-1/2"ST-14 LL9-7
1153"HQ LL7 ST-1222-1/2"ST-15 Grd-2nd
1143"HQ LL7 ST-1042-1/2"ST-16 LL6-3
1163"HQ LL7 ST-822-1/2"LL9
1174"HQ LL6 ST-322-1/2"LL8
1193"HQ LL6 ST-722-1/2"LL7
1234"HQ LL6 ST-1122-1/2"LL6
1184"HQ LL6 ST-512-1/2"LL5
1214"HQ LL6 ST-832-1/2"LL4
722, 22A1-5, 22B3"HQ LL6 ST-1242-1/2"LL3
1273"HQ LL5 ST-1032-1/2"LL2
1263"HQ LL5 ST-1212-1/2"LL1
224 & 24A4" & 3"HQ LL5 ST-712-1/2"GRD
1254"HQ LL5 ST-832-1/2"CUP ST-1
1283"HQ LL4 ST-1032-1/2"CUP ST-2
1293"HQ LL4 ST-1142-1/2"PG-P1
230 & 30A4"HQ LL4 ST-1282-1/2"PG-P2
1323"HQ LL4 ST-1382-1/2"PG-P3
1314"HQ LL4 ST-782-1/2"PG-P4
1334"HQ LL3 ST-1182-1/2"PG-P5
1344"HQ LL3 ST-1282-1/2"PG-P6
1353"HQ LL3 ST-1382-1/2"PG-P7
1374"HQ LL3 ST-8
1363"HQ LL3 ST-6
1383"HQ LL2 ST-11
1394"HQ LL2 ST-12
1403"HQ LL2 ST-13
1413"HQ LL2 ST-7
1423"HQ LL1 ST-11
1434"HQ LL1 ST-12
1443"HQ LL1 ST-13
1454"HQ LL1 ST-7
1463"HQ GRD ST-11
1474"HQ GRD ST-12
1483"HQ GRD ST-13
1494"HQ L2 ST-15
1504"HQ L2 ST-12
34"CUP
12-1/2"CUP
31-1/4"CUP
23"HQ LL9 Z1 SG
11-1/2"CUP Elev. Mach
3LL9 Switchgears3"LL9 Zone 1
1LL8 Switchgear3"LL8 Zone 5
3LL6 Switchgears3"LL6 Zone 19
6LL4 Switchgears3"LL4 Zone 30A
Total81Total12Total2Total2Total21Total36Total9Total160Total10Total3Total28

Vault

St. Elizabeth's Electrical Vault
Zone ControlsCheck ValvesBackflow PreventerDry Pipe ValvesButterfly w/ TamperFDC's & Test HeaderFlow SwtichAir CompressorSpecial Equipment
NumberSizeLocationNumberSizeLocationNumberSizeLocationNumberSizeLocationNumberSizeLocationNumberSizeLocationNumberSizeLocationNumberSizeLocationNumberDescription
14"Sprkr Closet16"Spkr Closet16"Spkr Closet14"Spkr Closet14"Free-standing14"Sprkr Closet1Sprkr Closet1South Tek Systems
14"FDC14"Free-standingNitrogen Generator
14"Test

Total 0 Total 3 Total 1 Total 1 Total 1 Total 2 Total 1 Total 1 Total 1

PHGB

St. Elizabeth's Pump House (PH) & Gen. Bldg. (GB)
Zone ControlsCheck ValvesOS&Y - Wall Post IndicatorBackflow PreventerButterfly w/ Tamper SwitchFDC'sFlow Switch
NumberSizeLocationNumberSizeLocationNumberSizeLocationNumberSizeLocationNumberSizeLocationNumberSizeLocationNumberSizeLocation
13"PH14"PH FDC13"PH16"GB23"GB Corridor14"PH23"GB Corridor
14"GB14"GB FDC14"GB114"GB
14"GB Manual Foam14"GB Manual Foam

Total 2 Total 3 Total 2 Total 2 Total 2 Total 3 Total 2

MISC

# of Systems

DOC 27

Bldg. 31 2 3" and 4" Shotgun Riser 2 Dry Pipe

Bldg 33/34 2 4" Shotgun Riser

Bldg. 48/49 1 3" Victaulic Check

MUP 1 3" Shotgun Riser

MUT 1

Gatehouse 1 2 2" Victaulic Check

Gatehouse 2 2 2" Victaulic Check

Gatehouse 4 1 4" Victaulic Check

Gatehouse 5 1 3" Victaulic Check

Gatehouse 6 1 4" Victaulic Check

File details come from the government source that posted it. Updated .