Amendment 0004 Vandeneberg.doc

DOC document 74 KB Posted

Attached to
Renovate Vandenberg Hall Phase 5 & Phase 6
Solicitation number
FA7000-10-R-0036
Issued by

About this file

Amendment 0004

View the file

Other files

File Type Posted
REVISED Q 93.docx DOCX document
CS5-6 - 08.23.10 - Revision 2 - 096519 - Resilient Tile Flooring.doc DOC document
CS5-6 - 08.23.10 - Revision 2 - 081113 - Hollow Metal Doors and Frames.doc DOC document
Millwork Details-Optimized.pdf PDF
08.26.2010 - Addendum No. 003.doc DOC document
CS5-6 - 08.23.10 - Revision 2 - 081416 - Flush Wood Doors.doc DOC document
Vandenberg Hall CS 5 - CS 6 - Bid Questions and Answers - 83-95.doc DOC document
Attendance Sheet 1.pdf PDF
08 24 2010 - Vandenberg Hall CS 5 - CS 6 - Bid Questions and Answers - 61 - 82 edited.docx DOCX document
01 32 01.00 10.pdf PDF
01 42 00 - Sources for Ref Publications.pdf PDF
01 33 00.pdf PDF
01 45 01.pdf PDF
01 35 26.doc DOC document
01 45 01.10.pdf PDF
Amendment 0003.docx DOCX document
Glass Installers Past Project Experience.docx DOCX document
Addendum No 002 Vandenberg.doc DOC document
Joint Venture JA.pdf PDF
08 23 2010 - Vandenberg Hall CS 5 - CS 6 - Bid Questions and Answers 30 -60.docx DOCX document
QAttachment 19- 29.docx DOCX document
Joint Venture JA.pdf PDF
Addendum 001.pdf PDF
Amendment 0002.pdf PDF
GENERAL DECISION CO20100006 CO6.docx DOCX document
Questions 1-18.docx DOCX document
Site visit 11 Aug 10.pdf PDF
Amendment.pdf PDF
J A Brand Name items.pdf PDF
J A Brand Name items.pdf PDF
Attendance Sheet Walk 1.pdf PDF
Atch 5 Performance Questionnaire.doc DOC document
Atch 4 DB Wage Decision Building 16 Jul 10.pdf PDF
FA7000-10-R-0036.pdf PDF
Joint Venture JA.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION J - LIST OF DOCUMENTS, EXHIBITS AND OTHER ATTACHMENTS

The Table of Contents has changed from:

Exhibit/Attachment Table of Contents

DOCUMENT TYPE
DESCRIPTION
PAGES
DATE
Attachment 01
Specs Renovate Vandenberg Hall Phase 5 - 6
823
07-JUL-2010
Attachment 02
Drawings CS-5 Renovate Vandenberg Hall
242
07-JUL-2010
Attachment 03
Drawings CS-6 Renovate Vandenberg Hall
223
07-JUL-2010
Attachment 04
Davis Bacon Wage Decison
5
13-AUG-2010
Attachment 05
Renovate Vandenberg Hall Performance Questionaire
8
19-JUL-2010
Attachment 06
DELETED Addendum 001- Spec Division 084000
2
16-AUG-2010
Attachment 07
Addendum 002, US Army Corps of Engineers
2
23-AUG-2010
Attachment 08
U.S. Army Corp of Engineers Specifications
104
16-AUG-2010
Attachment 09
Glass Installers Past Project Experience
1
24-AUG-2010

to:

Exhibit/Attachment Table of Contents

DOCUMENT TYPE
DESCRIPTION
PAGES
DATE
Attachment 01
Specs Renovate Vandenberg Hall Phase 5 - 6
823
07-JUL-2010
Attachment 02
Drawings CS-5 Renovate Vandenberg Hall
242
07-JUL-2010
Attachment 03
Drawings CS-6 Renovate Vandenberg Hall
223
07-JUL-2010
Attachment 04
Davis Bacon Wage Decison
5
13-AUG-2010
Attachment 05
Renovate Vandenberg Hall Performance Questionaire
8
19-JUL-2010
Attachment 06
DELETED Addendum 001- Spec Division 084000
2
16-AUG-2010
Attachment 07
Addendum 002, US Army Corps of Engineers
2
23-AUG-2010
Attachment 08
U.S. Army Corp of Engineers Specifications
104
16-AUG-2010
Attachment 09
Glass Installers Past Project Experience
1
24-AUG-2010
Attachment 10
Addendum 003
2
26-AUG-2010
Attachment 11
Specifications Revision
15
26-AUG-2010
Attachment 12
Revised Architectural Drawings
4
26-AUG-2010

SECTION L - INSTRUCTIONS, CONDITIONS AND NOTICES TO BIDDERS

The following have been modified:

INSTRUCTIONS TO OFFERORS

L-1 PROPOSAL PREPARATION INSTRUCTIONS

The proposal package must be completed and returned to the address in Block 7 of the SF 1442, prior to or at the date and time set for closing of proposals; see Block 13A of the SF 1442.

A. To assure timely and equitable evaluation of proposals, offerors must follow the instructions contained herein. Offerors are required to meet all solicitation requirements, including terms and conditions, representations and certifications, small business subcontracting plan and glass installation certifications. Failure to meet a requirement may result in an offer being ineligible for award. The government intends to award a contract without discussion with respective offerors. This includes the small business subcontracting plan. The small business subcontracting plan, if applicable, must be acceptable to the Contracting Officer at the time of proposal. If unacceptable the offeror may be ineligible for award. Offerors must clearly identify any exception to the solicitation terms and conditions and provide complete accompanying rationale. Proposals must be complete, self-sufficient, and respond directly to the requirements of this solicitation; alternate proposals will not be accepted. The response shall consist of two (2) separate volumes; Volume I - Price Proposal, Volume II – Past Performance Information.

B. The Contracting Officer has determined there is a high probability of adequate price competition in this acquisition. Upon examination of the initial offers, the contracting officer will review this determination and if, in the contracting officer's opinion, adequate price competition exists no additional cost information will be requested and certification under FAR 15.406-2 will not be required. However, if at any time during this competition the contracting officer determines that adequate price competition no longer exists offerors may be required to submit information to the extent necessary for the contracting officer to determine the reasonableness of the price.

C. Specific Instructions, SUBMIT THE FOLLOWING:

1. VOLUME I – PRICE PROPOSAL – No page limit. Submit original and two (2) copies and 1 compact disk with electronic data files, in accordance with paragraph D5 below.

(a) Complete blocks 14 through 20C of the RFP Section A, SF 1442. In doing so, the offeror accedes to the contract terms and conditions as written in the RFP Sections A through J. These sections constitute the model contract.

(b) Insert proposed prices in Section B for each contract line item number for CLIN 0001, CLIN 0002, CLIN 0003 and CLIN 0004.

(c) Complete the necessary fill-ins and certifications in Section K. Section K shall be returned in its entirety. For Section I the offeror shall submit only those pages that require a fill-in.

(d) A letter of authorization for the Contracting Officer to verify offeror’s financial responsibility. Include financial institution’s name, address, and primary point of contact and phone numbers for financial institutions.

(e) A letter from the offeror’s bonding company, stating the offeror’s bonding ability to meet the bonding requirements of the contract listed in Section F and the requirements of FAR clause 52.228-15. The letter will include the contractor’s ability to obtain bonding for the amount proposed in the offer.

(f) Submit a small business subcontracting plan, if applicable, in accordance with FAR 52.219-9 Alt II.

(g) Submit Glass Installer Certifications for all of the following products: Viracon, Kawneer and Elward Panels

2. VOLUME II – PAST PERFORMANCE INFORMATION - Limited to no more than 60 pages, excluding completed past performance questionnaires. Only references for the same or similar types (general construction) of contracts are desired. If a teaming arrangement is contemplated the page limits and submission listed below apply to the teaming partnership or joint venture; i.e. “60” total pages. Submit original plus two (2) copies, and 1 (one) compact disk with electronic data files.

(a) Quality and Satisfaction Rating for Contracts Completed in the Past Three Years: Provide any information currently available (letters, metrics, customer surveys, independent surveys, etc.) which demonstrates customer satisfaction with overall job performance and quality of completed product for same or similar type contract. In addition, explain corrective actions taken in the past, if any, for substandard performance and any current performance problems such as cost overruns, extended performance periods, numerous warranty calls, etc.

(b) Performance Surveys: The Government will evaluate the quality and extent of offeror's performance deemed relevant to the requirements of this RFP. The Government will use information submitted by the offeror and other sources such as other Federal Government offices and commercial sources, and may contact all sources by any means (phone, e-mail, mail etc.) to assess performance. Provide a list of no more than ten (10) of the most recent and relevant contracts performed for Federal agencies and commercial customers within the last 3 years from the issue date of this solicitation. Recent past performance is defined as past performance on contracts within the last three years from the issue date of this solicitation. Past performance for contracts exceeding the timeframe for this definition of recency will be excluded from evaluation. Relevant performance includes performance of efforts involving building construction, curtain wall systems and a broad range of rennovation projects to include performance or management of rennovation or modernization that is similar or greater in scope, magnitude and complexity than the effort described in this solicitation. Relevance will be determined based in part on the specific work the contractor is proposed to perform on this RFP. In the past performance information, directly link the past performance information submitted to the contractor having performed the effort, and tie the information to the work the contractor is proposed to perform on this effort. Describe management experience that demonstrates ability to manage, construct and renovate a large facility with an estimated value between $25,000,000 and $100,000,000. Describe why the listed contract/project is relevant. The evaluation of past performance information will take into account any past performance information pertaining to subcontractors, teaming partners, key personnel and predecessor companies, who have relevant experience, or subcontractors that will perform major or critical aspects of the requirement when such information is relevant to the instant acquisition as determined by the Contracting Officer. Furnish the following information for each contract referenced:

(i) Company/Division name

(ii) Product/Service (type of renovation or construction)

(iii) Contracting Agency/Customer

(iv) Contract Number

(v) Contract Type

(vi) Contract Dollar Value

(vii) Period of Performance

(viii) Verified, up-to-date name, physical address, e-mail address, facsimile & telephone number of the contracting officer or point of contact

(ix) Comments regarding compliance with contract terms and conditions

(x) Comments regarding any known performance deemed unacceptable to the customer, or not in accordance with the contract terms and conditions and mitigating circumstances, or actions taken to correct the unacceptable condition and preclude recurrence.

NOTE: Do not leave any of the above information blank. If not applicable to the specific contract request you state “not applicable”.

If a teaming arrangement is contemplated, provide complete information as to the arrangement, including any relevant and recent past performance information on previous teaming arrangements with same partner. If this is a first time joint effort, each party to the arrangement must provide a list of past and present relevant contracts.

(c) Subcontractor Consent: Past performance information pertaining to a subcontractor cannot be disclosed to the prime offeror without the subcontractor’s consent. Provide with the proposal a letter from all subcontractors that will perform major or critical aspects of the requirement, consenting to the release of their past performance information to the prime contractor.

(d) In addition to the above information, the offeror shall mail Attachment 5 of this solicitation, Past Performance Questionnaire (PPQ), to the list of most relevant contract references. Instruct these references to complete the Past Performance Questionnaire and return directly to:

10 CONS/LGCA

Attn: Brian Hayden, FA7000-10-R-0036

8110 Industrial Drive, Suite 200

USAFA, CO 80840

or via email to brian.hayden@usafa.af.mil. or linda.wennerberg@usafa.af.mil.

(e) Any past performance questionnaires sent directly from a proposing offeror will not be accepted or evaluated. For the purpose of expediency of evaluation, please instruct references to respond to the past performance questionnaire as soon as possible. The questionnaire need not be sent to customers where past performance records exist in the government’s Construction Contractor Assessment Systems (CCASS). Not more than ten (10) questionnaires may be submitted. It is the sole responsibility of the offerors to ensure questionnaires are submitted by the solicitation closing date. The offerors are encouraged to follow-up with respondents for completed questionnaires, but are not required to.

(f) In addition to the above information, the offeror shall complete and submit with the proposal, Glass Installers Past Project Experience Form (Attachment 9) listing relevent work experience of the proposed Glass contractor, for the past three (3) years.

D. Documents submitted in response to this solicitation must be fully responsive to and consistent with the following:

1. Requirements of the RFP, drawings, and the Specifications, and government standards and regulations pertaining to the specification.

2. Evaluation Factors for Award in Section M of this RFP.

3. Proposal Preparation Instructions contained in Section L of this RFP.

4. Any limitation on the number of proposal pages. Pages exceeding the page limitations set forth in this Section L will not be read or evaluated, and will be removed from the proposal.

5. Format for proposals - Volumes I and II shall be as follows:

(a) A page is defined as one face of an 8 ½” X 11” sheet of paper (white or ivory in color) containing information. Charts, tables, or diagrams, may not exceed 11” x 17” and each face will be counted as one page. Includes all appendices, charts, graphs, diagrams, tables, photographs, etc. Covers for volumes, table of contents, indices, title pages, cross reference indices, and section dividers/tables will not be included in the page count if they are inserted solely to provide ease to the reader in locating volumes/sections of the proposal. They will be counted if they contain any other information, (e.g. diagrams, extraneous data, etc). Pages marked “This page intentionally left blank” will not be counted.

(b) Typing shall not be less than 12 font, with 1” margins. Smaller, legible font size may be used for charts and tables.

(c) Elaborate formats, bindings or color presentations are not desired or required. Company Name and solicitation number shall be included in the header of each page. Submit the proposal using three ring binders; all binders shall be capable of lying flat when opened. Submit a separate binder for each Volume I and Volume II of the proposal.

(d) Electronic copies of all data submitted with the proposal shall be submitted on 1 (one) compact disk. Compact disks will be CD ROM in MS Word 2007, MS Excel 2007, any Microsoft Office 2007 product unless otherwise specified, or Adobe Acrobat. The paper or hard copy of the offeror’s proposal shall control any conflict between the electronic version and the paper copy submitted in response to this solicitation.

L-2 The estimated magnitude of this contract is between $25,000,000 and $100,000,000. Funds are not presently available for this project. No award will be made under this solicitation until funds are available. The Government reserves the right to cancel this solicitation, either before or after the closing date. This project is a Straddle A effort. The Government intends to award a contract for CLIN 0001. Option CLINs 0002, 0003 and 0004 may be awarded during the performance of CLIN 0001 subject to the availability of funding.

(End of Summary of Changes)

File details come from the government source that posted it. Updated .