0466-add 2.pdf

PDF 51 KB Posted

Attached to
Revitalize Water Distribution System
Solicitation number
FA6670-08-R-0003
Issued by

View the file

Other files

File Type Posted
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
Amendment 0001.pdf PDF
02081-02_C31.pdf PDF
02081-02_C17.pdf PDF
02081-02_C19.pdf PDF
02081-02_C03.pdf PDF
02081-02_C01.pdf PDF
02081-02_C24.pdf PDF
02081-02_C22.pdf PDF
02081-02_C09.pdf PDF
02081-02_C07.pdf PDF
02081-02_C26.pdf PDF
02081-02_T02.pdf PDF
02081-02_C13.pdf PDF
02081-02_C11.pdf PDF
02081-02_C33.pdf PDF
02081-02_T01.pdf PDF
02081-02_C05.pdf PDF
02081-02_C04.pdf PDF
02081-02_C06.pdf PDF
02081-02_C21.pdf PDF
02081-02_C14.pdf PDF
02510ARev1Pg5 6.pdf PDF
02921ARev1pg7.pdf PDF
02510ARev1Pg3.pdf PDF
02770ARev17 8.pdf PDF
01356ARev1.pdf PDF
Soil Boring Log.pdf PDF
Addendum1SKETCHS-17Jul07.pdf PDF
02770A.pdf PDF
01356A.pdf PDF
01670.pdf PDF
02302N.pdf PDF
swppp.pdf PDF
FIGURE 3.pdf PDF
01355A.pdf PDF
02510A.pdf PDF
AFF 3000.pdf PDF
02742N.pdf PDF
Ver2000_02081-02_C26.pdf PDF
01572.pdf PDF
01110N.pdf PDF
02081-02_C16.pdf PDF
SUBMITTAL LIST.pdf PDF
speccover.pdf PDF
SWP3-ES-Jun03 2.pdf PDF
FIGURE 2.pdf PDF
Questionnaire Cover Letter.pdf PDF
Davis Bacon Wage Determination.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10 September 07

ADDENDUM #2

PROJECT RVKQ 94-0466

Revitalize Water Distribution System

SCOPE OF WORK

Specifications

1. Delete Submittal Listing and Replace with attached Submittal Listing revised on 9/6/07.

2. Delete Section 01356A 1-6 and Replace with attached Section 01356A 1-19

3. Delete Table of Contents Page 1 and Replace with revised Table of Contents

4. Delete Section 01670 Page 1 and Replace with revised Section 01670 Page 1

5. Delete Section 02510A Page 3 and Replace with revised Section 02510A Page 3

6. Delete Section 02510A Page 5 & 6 and Replace with revised Section 02510A Page 5 & 6

7. ADD to Section 02770A Page 3 paragraph 2.1 last line “ Contractor shall refer to EPA’s recycled content guidelines regarding recycled content for this item”

8. Delete Section 02770A Page 7 & 8 and Replace with revised Section 02770A Page 7 & 8

9. Delete Section 02921A Page 7 and Replace with revised Section 02921A Page 7

10. Section 02510A Page 6 ADD Paragraph 2.2.1 “ All bolts supplied for use on this project shall be Stainless Steel”

11. Section 02302N Page 2 ADD to last line of Paragraph 1.2.4 “In order to ensure that the specified densities are being obtained, The contractor shall perform one (1) compaction test per 1000 lineal feet of pipeline installed. Test will be performed by an approved commercial testing laboratory at no additional cost to the government. Test results shall be furnished to the Contracting Officer”

Plans

1. Sheet 34 of 36 C-32 ADD to the typical trench detail the existing pavement section shall be at a minimum Typical thickness as follows: 12” Sub Base NYSDOT 304.3 Type 2, 3” Binder course NYSDOT 403.13 Type 3, 1 ½” Top course NYSDOT 403.18 Type 7.

Compaction shall be in accordance with Section 02742N.

2. Sheet 5 of 36 C-3 ADD at Station A0+00 to A1+00, 100 LF 24” Casing & Pipe per Detail on C-33 Sheet 35 of 36. 45° Bends and 10” Gate valve will be field adjusted to the east in order to accommodate the 24” casing pipe.

3. Sheet 13 of 36 C-11 Extend 45° bend at Station G5+90 40’ easterly into pavement area and maintain 8” pipeline northerly to relocated Tee & valves from station G10+75 to approx. Station 11+15. Select material and asphalt pavement will be required in parking lot area per Typical Trench detail shown on Sheet 34 of 35 C-32.

10 September 07

ADDENDUM #2

PROJECT RVKQ 94-0466

Revitalize Water Distribution System

SCOPE OF WORK

4. Additional Water Service Replacements All service connections shall include all necessary piping and appurtenances

Sheet 8 of 36 C-6 ADD 8” service connection at Station B7+30 for existing 8” service for Building 799 MEPS Facility. Connection will be located on the east side of Ent Avenue as shown on drawing. Existing 8” connection to be relocated from existing 8” waterline to new 8” waterline. Type B connection.

Sheet 14 of 36 C-12 ADD 3” service connection at Station H2+05 for existing 3” service for Building 821 Fire and Crash Rescue facility. New 12” water line will be located east of the existing 8” waterline as shown. Existing 3” connection to be relocated from existing 8” to new 12” waterline. Type B connection.

Sheet 26 of 36 C-24 ADD Two (2)- new 4” service connections – one (1) 4” domestic water and one (1) 4” Fire sprinkler connection at Station U4+75 for Building 500 Visiting Quarters. New 8” water line will be located east of the existing 8” waterline as shown. The two existing 4” connections are to be relocated east from existing 8” to new 8” waterline.

Type B & J connections.