02510ARev1Pg3.pdf

PDF 18 KB Posted

Attached to
Revitalize Water Distribution System
Solicitation number
FA6670-08-R-0003
Issued by

View the file

Other files

File Type Posted
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
Amendment 0001.pdf PDF
02081-02_C07.pdf PDF
02081-02_C26.pdf PDF
02081-02_T02.pdf PDF
02081-02_C13.pdf PDF
02081-02_C11.pdf PDF
02081-02_C33.pdf PDF
02081-02_T01.pdf PDF
02081-02_C05.pdf PDF
02081-02_C04.pdf PDF
02081-02_C31.pdf PDF
02081-02_C17.pdf PDF
02081-02_C19.pdf PDF
02081-02_C03.pdf PDF
02081-02_C01.pdf PDF
02081-02_C24.pdf PDF
02081-02_C22.pdf PDF
02081-02_C09.pdf PDF
02081-02_C06.pdf PDF
02081-02_C21.pdf PDF
02081-02_C14.pdf PDF
02921ARev1pg7.pdf PDF
02770ARev17 8.pdf PDF
01356ARev1.pdf PDF
02510ARev1Pg5 6.pdf PDF
Addendum1SKETCHS-17Jul07.pdf PDF
Soil Boring Log.pdf PDF
02510A.pdf PDF
AFF 3000.pdf PDF
02742N.pdf PDF
Ver2000_02081-02_C26.pdf PDF
01572.pdf PDF
01110N.pdf PDF
02081-02_C16.pdf PDF
SUBMITTAL LIST.pdf PDF
speccover.pdf PDF
02770A.pdf PDF
01356A.pdf PDF
01670.pdf PDF
02302N.pdf PDF
swppp.pdf PDF
FIGURE 3.pdf PDF
01355A.pdf PDF
SWP3-ES-Jun03 2.pdf PDF
FIGURE 2.pdf PDF
01330.pdf PDF
Davis Bacon Wage Determination.pdf PDF
Questionnaire Cover Letter.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REVITALIZE WATER DISTRIBUTION SYSTEM 94-0466

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 24 (1995) Installation of Private Fire Service Mains and Their Appurtenances

NFPA 49 (1994) Hazardous Chemicals Data

NFPA 325-1 (1994) Fire Hazard Properties of Flammable Liquids, Gases, and Volatile Solids

THE SOCIETY FOR PROTECTIVE COATINGS (SSPC)

SSPC Paint 21 (1991) White or Colored Silicone Alkyd Paint

SSPC Paint 25 (1991) Red Iron Oxide, Zinc Oxide, Raw Linseed Oil and Alkyd Primer (Without Lead and Chromate Pigments)

1.2 PIPING

This section covers water supply distribution service lines, and connections to building service at a point approximately 5 feet outside buildings and structures to which service is required.

The Contractor shall have a copy of the manufacturer's recommendations for each material or procedure to be utilized available at the construction site at all times.

1.2.1 Service Lines

Piping for water service lines less than 3 inches in diameter shall be galvanized steel, polyvinyl chloride (PVC) plastic, Oriented PVC plastic polyethylene, or copper tubing, unless otherwise shown or specified. Piping for water service lines 3 inches and larger shall be ductile iron, polyvinyl chloride (PVC) plastic, filament-wound or centrifugally cast reinforced thermosetting resin, reinforced plastic mortar pressure pipe or steel, unless otherwise shown or specified.

1.2.2 Distribution Lines (3 Inches) or Larger

Piping for water distribution lines 3 inches or larger shall be ductile iron, polyvinyl chloride (PVC) through 36 inch nominal diameter plastic, or reinforced concrete, unless otherwise shown or specified.

1.2.3 Supply Lines (3 Inches) or Larger

Piping for water supply lines 3 inches or larger shall be ductile iron, polyvinyl chloride (PVC) plastic reinforced concrete, unless otherwise shown or specified.

1.2.4 Sprinkler Supply Lines

Piping for water lines supplying sprinkler systems for building fire protection shall conform to NFPA 24 from the point of connection with the water distribution system to the building 5 foot line.

1.2.5 Excavation, Trenching, and Backfilling

Excavation, trenching, and backfilling shall be in accordance with the applicable provisions of Section 02302N EXCAVATION, TRENCHING, AND BACKFILLING FOR UTILITIES, except as modified herein.

SECTION 02510A Page 3

1.2 PIPING
1.2.1 Service Lines
1.2.2 Distribution Lines (3 Inches) or Larger
1.2.3 Supply Lines (3 Inches) or Larger
1.2.4 Sprinkler Supply Lines
1.2.5 Excavation, Trenching, and Backfilling

File details come from the government source that posted it. Updated .