This document is an appendix to a solicitation for ceramic tile installation services at Davis-Monthan Air Force Base in Tucson, Arizona. It provides product specifications for various types of ceramic tile, setting beds, mortars, grouts, and adhesives that may be required to complete the project. Material requirements include porcelain, mosaic, quarry, and glass wall tiles; floor tiles suitable for commercial use; cementitious backer boards; reinforcing wire fabric; and setting compounds. The appendix specifies standards such as ANSI A137.1 and ASTM C373 for tile, as well as LEED documentation and submittal requirements. It also outlines installation procedures for walls, floors, and transition strips.
SOW Appendix B
View the file
Other files for this federal contract opportunity
Show all 50
FY19-24 Davis-Monthan SABER Solicitation has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPENDIX B
SPECIFICATIONS
(Volume 02)
FOR
SIMPLIFIED ACQUISITION
OF
BASE ENGINEER REQUIREMENTS
(SABER)
AT
DAVIS-MONTHAN AIR FORCE BASE
TUCSON, ARIZONA
11 February 2019
Table of Contents-1
TECHNICAL PROVISIONS OF SPECIFICATIONS
SABER Contract (Volume 02)
Contractor to furnish all labor, equipment, appliance and materials and perform all operations in connection with all Task Orders issued under the SABER contract at Davis-Monthan AFB, Arizona, in strict accordance with these specifications.
TABLE OF CONTENTS
SECTION AND TITLE
DIVISION 09 – FINISHES
09 24 23 Stucco
09 29 00 Gypsum Board
09 30 13 Ceramic Tiling
09 51 00 Acoustical Ceilings
09 65 00 Resilient Flooring
09 68 00 Carpeting
09 69 13 Rigid Grid Access Flooring
09 83 13 Acoustical Wall Treatment
09 90 00 Paints and Coatings
DIVISION 10 – SPECIALTIES
10 14 00.20 Interior Signage
10 21 13 Toilet Compartments
10 28 13 Toilet Accessories
DIVISION 12 – FURNISHINGS
12 36 00 Countertops
DIVISION 15 – MECHANICAL SYSTEMS
15121 Expansion Compensation
15140 Supports and Anchors
15190 Mechanical Identification
15241 Vibration Isolation
15242 Vibration Isolation
Table of Contents-2
15260 Domestic Water Piping Insulation
15261 Hydronic Piping Insulation
15280 Equipment Insulation
15290 Ductwork Insulation
15310 Fire Protection Piping
15311 Fire Hydrants
15325 Wet Pipe Sprinkler Systems
15410 Sanitary Sewer, Waste and Vent System
15411 Domestic Water System
15412 Natural Gas System
15413 Condensate and Equipment Drains
15414 Compressed Air System
15430 Plumbing Specialties
15440 Plumbing Fixtures
15445 Gas-Fired Water Heaters
15446 Electric Water Heaters
15450 Plumbing Equipment
15510 Hydronic Piping
15515 Hydronic Specialties
15540 HVAC Pumps
15556 Cast Iron Boilers
15575 Breechings, Chimneys & Stacks
15624 Make-Up Air Units
15682 Air Cooled Water Chillers
15684 Make-Up Air Units
15760 Air Conditioning Units (Packaged Gas Heating, Electric Cooling)
15761 Air Conditioning Units (Electric Heating, Electric Cooling)
15762 Air Conditioning Units (Electric Cooling Only)
15765 Bypass Variable Air Volume (VAV) System
15771 Roof Mounting Frame and Base (For Air Conditioning Units)
15835 Terminal Heat Transfer Units
15855 Air Handling Units with Coils
15860 Centrifugal Fans
Table of Contents-3
15865 Axial Fans
15870 Power Ventilators
15885 Air Cleaning
15886 High Velocity Dust Collection Systems
15890 Low Pressure Ductwork
15891 Medium and High Pressure Ductwork
15892 Fiberglass Ductwork
15893 Underground Ductwork
15910 Ductwork Accessories
15930 Pressure Independent Air Terminal Units
15931 Pressure Dependent Air Terminal Units
15936 Air Outlets and Inlets
15973 Pneumatic Control Systems
15975 Direct Digital Control Systems
15976 Variable Speed Controllers
15980 Instrumentation
15990 Testing, Adjusting, and Balancing
USACE / NAVFAC / AFCEC / NASA UFGS-09 24 23 (May 2009) Change 1 - 11/12 Preparing Activity: USACE Superseding UFGS-09 24 23 (April 2006)
UNIFIED FACILITIES GUIDE SPECIFICATIONS
References are in agreement with UMRL dated January 2015
SECTION TABLE OF CONTENTS
DIVISION 09 - FINISHES
SECTION 09 24 23
STUCCO
05/09
PART 1 GENERAL
1.1 REFERENCES
1.2 SUSTAINABILITY REPORTING
1.3 SUBMITTALS
1.4 QUALITY ASSURANCE
1.5 DELIVERY, STORAGE, AND HANDLING
1.6 ENVIRONMENTAL REQUIREMENTS
PART 2 PRODUCTS
2.1 PORTLAND CEMENT
2.2 COLORED STUCCO FINISH COAT
2.3 LIME
2.4 SAND
2.5 ACCESSORIES
2.6 STEEL FRAMING
2.7 METAL LATH
2.8 WATER
PART 3 EXECUTION
3.1 FRAMING
3.2 CONTROL JOINTS
3.3 LATH
3.3.1 Steel and Wood Supports
3.3.2 On Concrete and Masonry
3.3.3 Over Metal Lintels and Flashings
3.3.4 Special Shapes, Profiles, and Contours
3.4 FURRING
3.5 PREPARATION OF SURFACES
3.6 PROPORTIONS AND MIXING
3.7 STUCCO APPLICATION
3.7.1 Workmanship
3.7.2 Scratch Coat
SECTION 09 24 23 Page 1
3.7.3 Brown Coat
3.7.4 Finish Coat
3.7.5 Surface Tolerance
3.8 CURING AND PROTECTION
3.9 PATCHING AND POINTING
-- End of Section Table of Contents --
SECTION 09 24 23 Page 2
USACE / NAVFAC / AFCEC / NASA UFGS-09 24 23 (May 2009) Change 1 - 11/12 Preparing Activity: USACE Superseding UFGS-09 24 23 (April 2006)
UNIFIED FACILITIES GUIDE SPECIFICATIONS
References are in agreement with UMRL dated January 2015
SECTION 09 24 23
STUCCO
05/09
NOTE: This section covers requirements for stucco, including associated framing and lathing.
Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.
Remove information and requirements not required in respective project, whether or not brackets are present.
Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR) .
PART 1 GENERAL
1.1 REFERENCES
NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.
Use the Reference Wizard's Check Reference feature when you add a RID outside of the Section's Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizard's Check Reference feature to update the issue dates.
SECTION 09 24 23 Page 3
References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM A1064/A1064M (2014) Standard Specification for Carbon-Steel Wire and Welded Wire Reinforcement, Plain and Deformed, for Concrete
ASTM C1032 (2014) Standard Specification for Woven Wire Plaster Base
ASTM C1063 (2014d) Standard Practice for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster
ASTM C150/C150M (2012) Standard Specification for Portland Cement
ASTM C206 (2003; R 2009) Standard Specification for Finishing Hydrated Lime
ASTM C841 (2003; R 2013) Installation of Interior Lathing and Furring
ASTM C847 (2014a) Standard Specification for Metal Lath
ASTM C897 (2005; R 2014) Aggregate for Job-Mixed Portland Cement-Based Plasters
ASTM C926 (2014a) Application of Portland Cement-Based Plaster
ASTM C933 (2014) Welded Wire Lath
ASTM D1784 (2011) Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds
U.S. GREEN BUILDING COUNCIL (USGBC)
LEED BD+C (2009; R 2010) Leadership in Energy and Environmental Design(tm) Building Design and Construction (LEED-NC)
1.2 SUSTAINABILITY REPORTING
SECTION 09 24 23 Page 4
SECTION 09 24 23 Page 5
NOTE: The bracketed items are representative of LEED material documentation and requirements that may apply to this project. These items should be edited to reflect the project requirements.
Materials in this technical specification may contribute towards contract compliance with sustainability requirements. See Section 01 33 29 SUSTAINABILITY REPORTING for project LEED BD+C [local/ regional materials][ and ][recycled content] and LEED documentation requirements.
1.3 SUBMITTALS
NOTE: Review and edit the following list to reflect only the submittals required for the project.
Submittals should be kept to the minimum required for adequate quality control.
Government approval is required for all submittal items. The following shall be submitted in accordance with paragraph 1.4 of Section 01010, SUMMARY OF WORK:
SECTION 09 24 23 Page 6
1.3.1 Shop Drawings
Lath
1.3.2 Product Data
Proportions and Mixing
1.3.3 Samples
Colored Stucco Finish Coat Sample Panel
1.3.4 Closeout Submittals
LEED Documentation
1.4 QUALITY ASSURANCE
Submit, if required, a SAMPLE PANEL as follows: [One 300 mm 12 inch square stucco panel showing finish texture and color and exposed reinforcement at the edges, one 300 mm 12 inch square of reinforcement, and a 300 mm 12 inch length of each accessory proposed, prior to proceeding with stucco work.] [A sample panel of stucco, constructed at the jobsite, and located as directed, to demonstrate installation procedures, texture and color, prior to proceeding with any stucco work; panel size shall be a minimum of 1200 mm wide x 2400 mm 4 feet wide x 8 feet high; containing each type accessory proposed for use and constructed in the vertical position. Sample panel shall have exposed reinforcement at the edges. Each phase of installation such as framing, scratch coat, brown coat, finish coat and curing procedures shall be demonstrated in the construction of the panel. Submit one 300 mm 12 inch square of reinforcement and one 300 mm 12 inch length of each accessory proposed for use, prior to constructing the sample panel.]
1.5 DELIVERY, STORAGE, AND HANDLING
Deliver packaged materials to the site in the original packages and containers with labels intact and seals unbroken. Keep cementitious materials dry and stored off the ground, under cover and away from damp surfaces until ready to be used. Aggregate shall be covered to prevent the absorption or loss of moisture.
1.6 ENVIRONMENTAL REQUIREMENTS
Do not apply stucco when the ambient temperature is 4 degrees C 40 degrees F or lower, or when a drop in temperature below 4 degrees C 40 degrees F is expected within 48 hours after application.
PART 2 PRODUCTS
2.1 PORTLAND CEMENT
NOTE: Where colored or white stucco finish is required, the gray portland cement will be omitted.
Select type of cement to provide the required characteristics. Type I cement should normally be specified when stucco requires no special characteristics. Type II cement should be specified when stucco will be exposed to moderate sulphate (alkali) action. Type III cement should be specified when high early strength is needed.
Portland cement shall conform to ASTM C150/C150M, [gray portland cement Type [I] [II] [III].] [white portland cement, Type [I] [II] [III].]
2.2 COLORED STUCCO FINISH COAT
Colored stucco finish coat shall be a mill mixed product using white portland cement and requiring only the addition of and mixing with water for application. Color shall be [in accordance with Section 09 06 90COLOR SCHEDULE] [_____]. Submit samples including both a fabricated portion of unit of work and color samples.
2.3 LIME
Lime shall conform to ASTM C206, Type S.
2.4 SAND
Sand aggregate for job-mixed base coat and job-mixed finish coat stucco shall conform to ASTM C897.
2.5 ACCESSORIES
NOTE: Custom aluminum radiuses, and custom miters and intersections with welded corners or taped backs are available. Aluminum shapes with clear anodized, color anodized, or baked enamel finishes may be used where required for aesthetic purposes. Aluminum shapes are more costly than standard steel or PVC shapes.
Accessories shall be [roll formed galvanized steel, or rigid polyvinyl chloride (PVC)] [_____], except that cornerite and striplath shall be formed from steel sheets with manufacturer's standard galvanized coating.
Vinyl members shall be in accordance with ASTM D1784. Welded wire corner reinforcements shall be zinc coated, galvanized 1.4 mm 17 gauge steel wire conforming to ASTM A1064/A1064M . Furring shall include hangers, bolts, inserts, clips, fastenings, and attachments of number, size, and design to develop the full strength of the members.
2.6 STEEL FRAMING
NOTE: Stud sizes and framing dimensions and details will be indicated on the drawings. Framing will be designed for a maximum deflection of L/240 studs only assembly or a maximum deflection of L/360 for completed assembly, based on wind load design requirements in UFC 3-301-01.
SECTION 09 24 23 Page 7
Steel framing shall be as shown and shall be manufacturers standard products with shop applied protective coating.
2.7 METAL LATH
Metal lath shall conform to ASTM C847, types and weights in accordance with the various spacing shown in ASTM C841. Lath for vertical application on steel and wood framing supports shall be expanded metal or welded or woven wire and shall have paper backing with a minimum vapor permeance of 287.2 ng per Pa per second per square meter 5 perms. Woven wire lath shall be a maximum 38 x 38 mm 1-1/2 x 1-1/2 inch mesh wire of not less than 1.37 mm
0.0540 inch nominal diameter and shall conform to ASTM C1032. Welded wire lath shall conform to ASTM C933, with openings not to exceed 50 x 50 mm 2 x 2 inches. Expanded metal or wire lath shall be fabricated in a manner to provide not less than 6 mm 1/4 inch keying between wire and paper backing and keying shall be obtained by a uniform series of slots in a perforated face paper woven between the wires.
2.8 WATER
Provide clean, fresh, potable water, free from amounts of oils, acids, alkalis and organic matter that would be injurious to the stucco.
PART 3 EXECUTION
3.1 FRAMING
Framing shall be installed as indicated.
3.2 CONTROL JOINTS
NOTE: Control joints will be shown on the drawings, dividing the stucco into areas of not more than 13 square meters (144 square feet) with no dimension between control joints greater than 5.4 meters (18 feet). The length to width ratio of the area bounded by the control joints will not exceed 25 to 63 mm (1 to 2-1/2 inches).
Control joints shall be located as indicated on the drawings.
Prefabricated control joint members shall be installed prior to the application of the stucco. Control joints shall be cleared of all stucco within the control area after stucco application and prior to final stucco set.
3.3 LATH
NOTE: Drawings will clearly indicate where metal lath is required. Metal lath will be used over metal supports and wood supports. Metal reinforcement with water-resistant paper is recommended in all steel frame construction and suspended ceilings. The use of metal reinforcement over concrete and masonry will be in accordance with local practice based upon satisfactory experience.
Paper backed lath may be applied to interior
SECTION 09 24 23 Page 8 concrete and masonry when adequate and uniform bond cannot be obtained otherwise, and when the lath will be protected from moisture.
Install lath in accordance with ASTM C841 or ASTM C1063 except as otherwise specified. Metal and wire lath shall be applied straight, without buckles and with joints staggered. End laps of metal lath shall be not less than 25 mm 1 inch. When paper-backed lath is used, the paper shall be split from the lath at all lap areas to provide a paper to paper and lath to lath lap. Horizontal joints shall be shiplapped. Lath shall be interrupted at all control joints. Submit drawings showing details of construction for reinforcement, furring, and grounds; including manufacturer's installation instructions for stucco materials, and locations where each mix and coating thickness will be used.
3.3.1 Steel and Wood Supports
Apply metal lath over vertical open or solid wood and steel backing frame construction only after sheathing and air barrier has been applied to the area to receive the stucco. Fasten lath every 200 mm 8 inches vertically and every 400 mm 16 inches horizontally; and where sheets of lath are lapped. Drive fasteners to hold both lapped edges securely in place.
3.3.2 On Concrete and Masonry
Fasten lath every 200 mm 8 inches vertically and every 400 mm 16 inches horizontally. Where wood supports adjoin masonry or concrete in the same direction, provide casing bead, control joints, or reinforcement as indicated.
3.3.3 Over Metal Lintels and Flashings
Lath over metal lintels shall be extended vertically over the angles to a height of not less than 150 mm 6 inches and horizontally across the underside of the lintels and shall be secured in an approved manner. Lath over metal flashings shall lap the flashings not less than 50 mm 2 inches and shall be extended vertically for a height of not less than 150 mm 6 inches.
3.3.4 Special Shapes, Profiles, and Contours
Special shapes, profiles, and contours shall be formed with wood, metal or aluminum furring and reinforcing.
3.4 FURRING
Furring shall be installed to true lines and surfaces and shall be rigidly supported and secured in place.
3.5 PREPARATION OF SURFACES
Preparation of surfaces for application of stucco to solid bases such as stone, masonry or concrete shall conform to the applicable requirements of
ASTM C926.
3.6 PROPORTIONS AND MIXING
Proportions and mixing for job-mixed base coat and finish coat shall
SECTION 09 24 23 Page 9 conform to the applicable requirements of ASTM C926. Mixing of mill-mixed finish coat shall be in accordance with the manufacturer's directions.
Submit detailed description of the proposed job-mix proportions for base and finish coats; including identification of thickness of coats.
3.7 STUCCO APPLICATION
Stucco shall be applied in three coats to a thickness of not less than 25 mm 1 inch as measured from the back plane of metal reinforcement, exclusive of ribs or dimples or from the face of solid backing or support, with or without metal reinforcement, to the finished stucco surface, including moderate texture variations. Stucco application shall conform to the applicable requirements of ASTM C926 and the following:
3.7.1 Workmanship
Items or features of the work in connection with or adjoining the stucco shall be in place, plumb, straight, and true prior to beginning the stucco work. Metal and wire lath, where required, shall be in place and positioned to provide a good key at back of lath. Where lath is applied over copper, the copper shall be given a heavy coat of bituminous paint.
Masonry surfaces to receive stucco shall be evenly dampened immediately prior to application of stucco. Each stucco coat shall be applied continuously in one general direction, without allowing mortar to dry at edges. Where it is impossible to work the full dimension of a wall surface in a continuous operation, jointing shall be made at a break, opening, or other natural division of the surface. Edges to be joined shall be dampened slightly to produce a smooth confluence. Exterior corners of stucco shall be slightly rounded. Stucco on soffit surfaces shall be pitched forward to form a drip.
3.7.2 Scratch Coat
Apply scratch coat not less than 10 mm 3/8 inch thick under sufficient pressure to form good keys and to completely embed the reinforcement.
Before the scratch coat has set, it shall be lightly scratched in one direction and vertical surfaces shall be scratched in the horizontal direction only. The scratch coat shall be fog cured for a minimum of 72 hours.
3.7.3 Brown Coat
Evenly dampen the scratch coat to obtain uniform suction before the brown coat is applied. There shall be no visible water on the surface when the brown coat is applied. The brown coat shall be applied to the scratch coat with sufficient pressure to force the stucco into the scratches and shall be brought to a plumb, true, even plane with rod or straightedge. When set sufficiently, the brown coat shall be uniformly floated with a dry float to promote densification of the coat and to provide a surface receptive to bonding of the finish coat. Brown coat shall be fog cured for a minimum of 72 hours.
3.7.4 Finish Coat
Dampen surfaces of the brown coat not more than 1 hour before the finish coat is to be applied to a uniform wetness with no free-standing water on the surface. The finish coat shall have a [smooth trowel] [float] [trowel-textured] [rough-textured] [spray-textured] [exposed aggregate] finish and shall conform to the approved sample. Fog cure the finish coat
SECTION 09 24 23 Page 10 for a minimum of 48 hours. Take care to prevent staining.
3.7.5 Surface Tolerance
When a 3 m 10 foot straightedge is placed at any location on the finished surface of the stucco, excluding rough-textured finish, the surface shall not vary more than 3 mm 1/8 inch from the straightedge.
3.8 CURING AND PROTECTION
Perform fog curing by applying a fine mist of water to the stucco.
Exercise care during fog curing to avoid erosion damage of the stucco surfaces. Do not use a solid stream of water. Fognot less than three times daily. Protect the stucco from the direct rays of the sun during severe drying conditions using canvas, cloth or other approved sheet material.
3.9 PATCHING AND POINTING
Replace or patch loose, cracked, damaged or defective work as directed.
Patching shall match existing work in texture and color and shall be finished flush.
-- End of Section --
SECTION 09 24 23 Page 11
USACE / NAVFAC / AFCEC / NASA UFGS-09 29 00 (May 2011) Change 1 - 05/13 PREPARING ACTIVITY: NAVFAC Superseding UFGS-09 29 00 (August 2010)
UNIFIED FACILITIES GUIDE SPECIFICATIONS
References are in agreement with UMRL dated January 2015
SECTION TABLE OF CONTENTS
DIVISION 09 - FINISHES
SECTION 09 29 00
GYPSUM BOARD
05/11
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 SUSTAINABLE DESIGN CERTIFICATION
1.4 DELIVERY, STORAGE, AND HANDLING
1.4.1 Delivery
1.4.2 Storage
1.4.3 Handling
1.5 ENVIRONMENTAL CONDITIONS
1.5.1 Temperature
1.5.2 Exposure to Weather
1.5.3 Temporary Ventilation
1.6 SUSTAINABLE DESIGN REQUIREMENTS
1.6.1 Local/Regional Materials
1.6.2 Environmental Data
1.7 QUALIFICATIONS
1.8 SCHEDULING
PART 2 PRODUCTS
2.1 MATERIALS
2.1.1 Gypsum Board
2.1.1.1 Regular
2.1.1.2 Foil-Backed
2.1.1.3 Type X (Special Fire-Resistant)
2.1.2 Gypsum Backing Board
2.1.2.1 Regular
2.1.2.2 Foil-Backed
2.1.2.3 Type X (Special Fire-Resistant)
2.1.3 Regular Water-Resistant Gypsum Backing Board
2.1.3.1 Regular
2.1.3.2 Type X (Special Fire-Resistant)
2.1.4 Glass Mat Water-Resistant Gypsum Tile Backing Board
2.1.4.1 Regular
SECTION 09 29 00 Page 1
2.1.4.2 Type X (Special Fire-Resistant)
2.1.5 Glass Mat Covered or Reinforced Gypsum Sheathing
2.1.5.1 Glass Mat Covered or Reinforced Gypsum Sheathing Sealant
2.1.6 Impact Resistant Gypsum Board
2.1.6.1 Structural Failure Test
2.1.6.2 Indentation Test
2.1.7 Predecorated Gypsum Board
2.1.8 Cementitious Backer Units
2.1.9 Joint Treatment Materials
2.1.9.1 Embedding Compound
2.1.9.2 Finishing or Topping Compound
2.1.9.3 All-Purpose Compound
2.1.9.4 Setting or Hardening Type Compound
2.1.9.5 Joint Tape
2.1.10 Fasteners
2.1.10.1 Nails
2.1.10.2 Screws
2.1.10.3 Staples
2.1.11 Adhesives
2.1.11.1 Adhesive for Fastening Gypsum Board to Metal Framing
2.1.11.2 Adhesive for Fastening Gypsum Board to Wood Framing
2.1.11.3 Adhesive for Laminating
2.1.12 Gypsum Studs
2.1.13 Shaftwall Liner Panel
2.1.14 Accessories
2.1.15 Asphalt Impregnated Building Felt
2.1.16 Water
PART 3 EXECUTION
3.1 EXAMINATION
3.1.1 Framing and Furring
3.1.2 [Gypsum Board] [and] [Framing]
3.1.3 [Masonry] [and] [Concrete] Walls
3.2 APPLICATION OF GYPSUM BOARD
3.2.1 Application of Single-Ply Gypsum Board to Wood Framing
3.2.2 Application of Two-Ply Gypsum Board to Wood Framing
3.2.3 Adhesive Nail-On Application to Wood Framing
3.2.4 Semi-Solid Gypsum Board Partitions
3.2.5 Solid Gypsum Board Partitions
3.2.6 Adhesive Application to Interior Masonry or Concrete Walls
3.2.7 Application of Gypsum Board to Steel Framing and Furring
3.2.8 Arches and Bending Radii
3.2.9 Gypsum Board for Wall Tile or Tile Base Applied with Adhesive
3.2.10 Exterior Application
3.2.11 Glass Mat Covered or Fiber Reinforced Gypsum Sheathing
3.2.12 Floating Interior Angles
3.2.13 Control Joints
3.2.14 Application of Foil-Backed Gypsum Board
3.2.15 Application of Predecorated Gypsum Board
3.2.16 Application of Impact Resistant Gypsum Board
3.3 APPLICATION OF CEMENTITIOUS BACKER UNITS
3.3.1 Application
3.3.2 Joint Treatment
3.4 FINISHING OF GYPSUM BOARD
3.4.1 Uniform Surface
3.4.2 Metal Trim for Predecorated Gypsum Board
3.5 SEALING
3.5.1 Sealing for Glass Mat or Reinforced Gypsum Board Sheathing
SECTION 09 29 00 Page 2
3.6 FIRE-RESISTANT ASSEMBLIES
3.7 PATCHING
3.8 SHAFTWALL FRAMING
3.9 WASTE MANAGEMENT
SECTION 09 29 00 Page 3
USACE / NAVFAC / AFCEC / NASA UFGS-09 29 00 (May 2011) Change 1 - 05/13 PREPARING ACTIVITY: NAVFAC Superseding UFGS-09 29 00 (August 2010)
UNIFIED FACILITIES GUIDE SPECIFICATIONS
References are in agreement with UMRL dated January 2015
SECTION 09 29 00
GYPSUM BOARD
05/11
NOTE: This guide specification includes the requirements for gypsum board, cementitious backer units, and accessories intended for use in drywall construction.
Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.
Remove information and requirements not required in respective project, whether or not brackets are present.
Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR) .
Reference Section 05 40 00 COLD-FORMED METAL FRAMING for load bearing studwork. Reference Section 09 22 00 SUPPORTS FOR PLASTER AND GYPSUM BOARD for non-loadbearing studs, furring and ceiling suspension systems.
NOTE: On the drawings, show:
1. Locations of each type of gypsum board, backing board and cementitious backer units, using same terminology as in the specification.
2. Locations and UL or GA design numbers for fire rated gypsum board and cementitious backer unit assemblies.
SECTION 09 29 00 Page 4
3. Locations of asphalt impregnated building felt if gypsum sheathing is used or if cementitious backer units are used in wet areas.
PART 1 GENERAL
1.1 REFERENCES
NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.
Use the Reference Wizard's Check Reference feature when you add a RID outside of the Section's Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizard's Check Reference feature to update the issue dates.
References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
ANSI A108.11 (1992; Reaffirmed 2005) Specifications for Interior Installation of Cementitious Backer Units
ASTM INTERNATIONAL (ASTM)
ASTM C1002 (2014) Standard Specification for Steel Self-Piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs
ASTM C1047 (2014a) Standard Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base
ASTM C1177/C1177M (2013) Standard Specification for Glass Mat Gypsum Substrate for Use as Sheathing
ASTM C1178/C1178M (2013) Standard Specification for Glass Mat Water-Resistant Gypsum Backing Panel
ASTM C1396/C1396M (2014a) Standard Specification for Gypsum
SECTION 09 29 00 Page 5
Board
ASTM C1629/C1629M (2014a) Standard Classification for Abuse-Resistant Nondecorated Interior Gypsum Panel Products and Fiber-Reinforced Cement Panels
ASTM C475/C475M (2012; E 2014) Joint Compound and Joint Tape for Finishing Gypsum Board
ASTM C514 (2004; R 2014) Standard Specification for Nails for the Application of Gypsum Board
ASTM C557 (2003; E 2009; R 2009) Adhesives for Fastening Gypsum Wallboard to Wood Framing
ASTM C840 (2013) Application and Finishing of Gypsum Board
ASTM C954 (2011) Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from
0.033 in. (0.84 mm) to 0.112 in. (2.84 mm) in Thickness
ASTM D1037 (2012) Evaluating Properties of Wood-Base Fiber and Particle Panel Materials
ASTM D1149 (2007; R 2012) Standard Test Method for Rubber Deterioration - Surface Ozone Cracking in a Chamber
ASTM D226/D226M (2009) Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing
ASTM D2394 (2005; R 2011) Simulated Service Testing of Wood and Wood-Base Finish Flooring
ASTM D412 (2006a; R 2013) Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers - Tension
ASTM D5420 (2010) Impact Resistance of Flat, Rigid Plastic Specimen by Means of a Strike Impacted by a Falling Weight (Gardner Impact)
ASTM D624 (2000; R 2012) Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
ASTM E2129 (2010) Standard Practice for Data Collection for Sustainability Assessment of Building Products
ASTM E695 (2003; R 2009) Measuring Relative Resistance of Wall, Floor, and Roof Construction to Impact Loading
SECTION 09 29 00 Page 6
SECTION 09 29 00 Page 7
ASTM E84 (2014) Standard Test Method for Surface Burning Characteristics of Building Materials
GYPSUM ASSOCIATION (GA)
GA 214 (2010) Recommended Levels of Gypsum Board Finish
GA 216 (2010) Application and Finishing of Gypsum Panel Products
GA 224 (2008) Installation of Predecorated Gypsum Board
GA 253 (2012) Application of Gypsum Sheathing
GA 600 (2009) Fire Resistance Design Manual
SCIENTIFIC CERTIFICATION SYSTEMS (SCS)
SCS Scientific Certification Systems (SCS)Indoor Advantage
U.S. GREEN BUILDING COUNCIL (USGBC)
LEED NC (2009) Leadership in Energy and Environmental Design(tm) New Construction Rating System
UL ENVIRONMENT (ULE)
ULE Greenguard UL Greenguard Certification Program
UNDERWRITERS LABORATORIES (UL)
UL Fire Resistance (2012) Fire Resistance Directory
1.2 SUBMITTALS
NOTE: Review and edit the following list to reflect only the submittals required for the project.
Submittals should be kept to the minimum required for adequate quality control.
SECTION 09 29 00 Page 8
Government approval is required for all submittal items. The following
SUMMARY OF WORK:
1.2.1 Product Data
Cementitious backer units
Glass Mat Water-Resistant Gypsum Tile Backing Board
Water-Resistant Gypsum Backing Board
Glass Mat Covered or Reinforced Gypsum Sheathing
Glass Mat Covered or Reinforced Gypsum Sheathing Sealant
Impact Resistant Gypsum Board
Accessories
Submit for each type of gypsum board and for cementitious backer units.
Certification
Gypsum Board; (LEED NC)
Submit documentation indicating percentage of post-industrial and post-consumer recycled content per unit of product. Indicate relative dollar value of recycled content products to total dollar value of products included in project.
Adhesives; (LEED NC)
SECTION 09 29 00 Page 9
Joint Treatment Materials
Submit manufacturer's product data, indicating VOC content.
Local/Regional Materials; (LEED NC)
Documentation indicating distance between manufacturing facility and the project site. Indicate distance of raw material origin from the project site. Indicate relative dollar value of local/regional materials to total dollar value of products included in project.
Environmental Data
1.2.2 Samples
Predecorated gypsum board
Submit for each color and pattern of predecorated gypsum board.
Where colors are not indicated, submit color selection samples of not less than eight of the manufacturer's standard colors.
1.2.3 Certificates
Asbestos Free Materials
Certify that gypsum board types, gypsum backing board types, cementitious backer units, and joint treating materials do not contain asbestos.
1.2.4 Manufacturer's Instructions
Material Safety Data Sheets
1.2.5 Operation and Maintenance Data
Manufacturer maintenance instructions
Waste Management
1.2.6 Closeout Submittals
Local/Regional Materials; (LEED)
LEED documentation relative to local/regional materials credit in accordance with LEED Reference Guide. Include in LEED Documentation Notebook.
Gypsum Board; (LEED)
LEED documentation relative to recycled content credit in accordance with LEED Reference Guide. Include in LEED Documentation Notebook.
Adhesives; (LEED)
LEED documentation relative to low emitting materials credit in accordance with LEED Reference Guide. Include in LEED Documentation Notebook.
1.3 [ SUSTAINABLE DESIGN CERTIFICATION
NOTE: Products meeting the Gold standard will also meet the basic standard. Require Gold when the facility will be used by people sensitive to air quality conditions, such as child development centers and medical facilties.
Product shall be third party certified in accordance with ULE Greenguard [ Gold], SCS Scientific Certification Systems Indoor Advantage[ Gold ]or equal. Certification shall be performed annually and shall be current.]
1.4 DELIVERY, STORAGE, AND HANDLING
1.4.1 Delivery
Deliver materials in the original packages, containers, or bundles with each bearing the brand name, applicable standard designation, and name of manufacturer, or supplier.
1.4.2 Storage
NOTE: Gypsum board provides a sink for adsorbing high short-term emissions of VOCs, formaldehyde, particulates, or other air-borne compounds.
Materials with high short-term emissions include, but are not limited to: adhesives, sealants and glazing compounds (specifically those with petrochemical vehicles or carriers); paint, wood preservatives, and finishes; control and/or expansion joint fillers; hard finishes requiring adhesive installation; gypsum board (with associated finish processes and products); and composite or engineered wood products with formaldehyde binders.
Keep materials dry by storing inside a sheltered building. Where necessary to store gypsum board and cementitious backer units outside, store off the ground, properly supported on a level platform, and protected from direct exposure to rain, snow, sunlight, and other extreme weather conditions.
Provide adequate ventilation to prevent condensation. Store per manufacturer's recommendations for allowable temperature and humidity range. Gypsum wallboard shall not be stored with materials which have high emissions of volatile organic compounds (VOCs) or other contaminants, including [_____]. Do not store panels near materials that may offgas or emit harmful fumes, such as kerosene heaters, fresh paint, or adhesives.
1.4.3 Handling
Neatly stack gypsum board and cementitious backer units flat to prevent sagging or damage to the edges, ends, and surfaces.
SECTION 09 29 00 Page 10
1.5 ENVIRONMENTAL CONDITIONS
1.5.1 Temperature
Maintain a uniform temperature of not less than 10 degrees C 50 degrees F in the structure for at least 48 hours prior to, during, and following the application of gypsum board, cementitious backer units, and joint treatment materials, or the bonding of adhesives.
1.5.2 Exposure to Weather
Protect gypsum board and cementitious backer unit products from direct exposure to rain, snow, sunlight, and other extreme weather conditions.
1.5.3 Temporary Ventilation
Provide temporary ventilation for work of this section.
1.6 SUSTAINABLE DESIGN REQUIREMENTS
1.6.1 Local/Regional Materials
NOTE: Using local materials can help minimize transportation impacts, including fossil fuel consumption, air pollution, and labor. Using materials harvested and manufactured within a 500 mile radius from the project site contributes to the following LEED credit: MR5. Coordinate with Section 01 33 29 LEED(tm) DOCUMENTATION. Use second option if Contractor is choosing local materials in accordance with Section 01 33 29 LEED(tm) DOCUMENTATION. First option shall not be used for USACE projects. Army projects shall include second option only if pursuing this LEED credit.
[Use materials or products extracted, harvested, or recovered, as well as manufactured, within a [800][_____] kilometer [500][_____] mile radius from the project site, if available from a minimum of three sources.][See Section 01 33 29 LEED(tm) DOCUMENTATION for cumulative total local material requirements. Gypsum board materials may be locally available.]
1.6.2 Environmental Data
NOTE: ASTM E2129 provides for detailed documentation of the sustainability aspects of products used in the project. This level of detail may be useful to the Contractor, Government, building occupants, or the public in assessing the sustainability of these products.
[Submit Table 1 of ASTM E2129 for the following products: [_____].]
1.7 QUALIFICATIONS
Furnish type of gypsum board work specialized by the installer with a
SECTION 09 29 00 Page 11 minimum of [3] [_____] years of documented successful experience.
1.8 SCHEDULING
NOTE: One or both of the following procedures shall be used to minimize the exposure of gypsum wallboard to materials or finishes which have high short-term emissions of VOCs, formaldehyde, particulates, or other air-borne compounds.
[The gypsum wallboard shall be taped, spackled and primed before the installation of the highly-emitting materials, including [_____].] [The gypsum wallboard shall be installed after the installation and ventilation period of the highly-emitting materials, including [_____].]
PART 2 PRODUCTS
2.1 MATERIALS
NOTE: Check ASTM C840, GA 216 and ANSI A108.11 for details of materials, fasteners, and application.
Conform to specifications, standards and requirements specified. Provide gypsum board types, gypsum backing board types, cementitious backing units, and joint treating materials manufactured from asbestos free materials only.
Submit Material Safety Data Sheets and manufacturer maintenance instructions for gypsum materials including adhesives.
2.1.1 Gypsum Board
Use of materials with recycled content, calculated on the basis of post-industrial and post-consumer percentage content, contributes to the following LEED credit: MR4. Designer must verify suitability, availability and adequate competition (including verification of bracketed percentages included in this guide specification) before specifying product recycled content requirements.
Use last option if Contractor is choosing recycled content products in accordance with Section 01 33 29 LEED(tm) DOCUMENTATION. Army projects shall specify recycled content only if pursuing this LEED credit
ASTM C1396/C1396M . [Gypsum board shall contain a minimum of [5][10][_____] percent post-consumer recycled content, or a minimum of [20][40][_____] percent post-industrial recycled content.] [Paper facings shall contain [100][_____] percent post-consumer recycled paper content. Gypsum cores shall contain a minimum of [95][_____] percent post-industrial recycled gypsum content.][See Section 01 33 29 LEED(tm) DOCUMENTATION for cumulative total recycled content requirements. Gypsum board may contain post-consumer or post-industrial recycled content.]
SECTION 09 29 00 Page 12
2.1.1.1 Regular
NOTE: Use tapered and featured edge gypsum board with embedding and finishing compounds when a very flat surface is required, such as long walls with lighting at the end of the wall and down or up lighted walls.
1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, [tapered][, tapered and featured] edges. [Provide tapered and featured edge gypsum board [in Rooms [_____] ] [as indicated].]
2.1.1.2 Foil-Backed
1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, [tapered] [tapered and featured] edges.
2.1.1.3 Type X (Special Fire-Resistant)
1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, [tapered] [tapered and featured] edges.
2.1.2 Gypsum Backing Board
NOTE: When thicker board is needed, replace the term "backing board" with "coreboard", and change dimension to 19.05 to 25.4 mm 3/4" to 1", depending on system used.
ASTM C1396/C1396M , gypsum backing board shall be used as a base in a multilayer system.
2.1.2.1 Regular
1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, square edges.
2.1.2.2 Foil-Backed
1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, square edges.
2.1.2.3 Type X (Special Fire-Resistant)
1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, square edges.
2.1.3 Regular Water-Resistant Gypsum Backing Board
NOTE: For adhesive applied ceramic tile in wet areas (tubs, shower enclosures, saunas, steam rooms, gang shower rooms, etc.), use cementitious backer units (Tile Council of America (TCA) Handbook) as a substrate. Specify ASTM C1396/C1396M or ASTM
SECTION 09 29 00 Page 13
C1178/C1178M for all other tiled areas including areas where only ceramic or quarry tile base is to be installed, and for ceilings in humid areas. When using water-resistant gypsum backing board at tile applications, the metal studs should not be spaced more than 406 mm 16 inches o.c. Specify moisture resistant gypsum board ASTM C1396/C1396M for humid areas that are not exposed to direct moisture.
When using moisture resistant board on ceilings, spacing of supports should be no more than 305 mm 12 inch on center.
NOTE: Additives used to produce water-resistant gypsum board ("green board") may include VOCs.
Water-resistant types may be difficult to recycle.
ASTM C1396/C1396M
2.1.3.1 Regular
1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, tapered edges.
2.1.3.2 Type X (Special Fire-Resistant)
1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, tapered edges.
2.1.4 Glass Mat Water-Resistant Gypsum Tile Backing Board
ASTM C1178/C1178M
2.1.4.1 Regular
1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, square edges.
2.1.4.2 Type X (Special Fire-Resistant)
1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, square edges.
2.1.5 [ Glass Mat Covered or Reinforced Gypsum Sheathing
NOTE: This section should be used where exterior gypsum sheathing with water resistance is required (i.e. cavity sheathing over metal studs with brick veneer or as substrate for EIFS systems). Always use asphalt impregnated felt paper for sheathing protection. For additional protection or if recommended by the manufacturer, choose the paragraph for sheathing sealant.
SECTION 09 29 00 Page 14
NOTE: Glass-fiber reinforced types may be difficult to recycle.
Exceeds physical properties of ASTM C1396/C1396M and ASTM C1177/C1177M .
Provide [12.7] [15.9,] mm [1/2][5/8] inch, gypsum sheathing. Provide gypsum board of with a noncombustible water-resistant core, with glass mat surfaces embedded to the gypsum core or reinforcing embedded throughout the gypsum core. Warrant gypsum sheathing board for at least twelve months against delamination due to direct weather exposure. Provide continuous, asphalt impregnated, building felt to cover exterior face of sheathing.
Seal [all joints, seams, and penetrations with compatible sealant.]
2.1.5.1 [ Glass Mat Covered or Reinforced Gypsum Sheathing Sealant
Provide sealant compatible with gypsum sheathing, rubber washers for masonry veneer anchors, and other associated cavity wall components such as anchors and through wall flashing. Provide sealants for gypsum sheathing board edge seams and veneer anchor penetrations recommended by the gypsum sheathing manufacturer and have the following performance requirements:
a. ASTM D412: Tensile Strength, 551 kilopascals 80 psi
b. ASTM D412: Ultimate Tensile Strength (maximum elongation), 1172 kilopascals 170 psi
c. ASTM D624: Tear Strength, dieB, 4.7 kN/m 27 ppi
d. ASTM D1149: Joint Movement Capability after 14 Days cure, plus or minus
50 percent.
] ] 2.1.6 [ Impact Resistant Gypsum Board
Note: Impact Resistant Gypsum Board Should Be Used When Abuse Or Vandalism Of Walls Is Anticipated And Gypsum Board Is The Only Wall Material Alternative Feasible. Consult Manufacture For Use Restrictions Of Impact Resistant Gypsum Board On Exterior Walls.
This Product Requires A Minimum Of 20 Gauge Metal Framing As Support, Coordinate with Section 09 22 00
SUPPORTS FOR PLASTER AND GYPSUM BOARD.
Some products rely on lexan backing for penetration resistance. The impervious layer will act as a vapor barrier which may not be desirable in certain wall systems and climates.
None of the paper faced gypsum products have high resistance to abrasion. Designer should consider high strength veneer plaster on wall systems using impact resistant gypsum wallboard, coordinate with Section 09 26 00 VENEER PLASTER.
1200 mm 48 inchwide, 15.9 mm 5/8 inch thick, tapered edges.
Reinforced gypsum panel with imbedded fiber mesh or lexan backing testing in accordance with the following tests. Hard body impact test must attain a Level 2 performance in accordance with ASTM C1629/C1629M . Provide fasteners that meet manufacturer requirements and specifications stated within this section. Impact resistant gypsum board, when tested in
SECTION 09 29 00 Page 15 accordance with ASTM E84, have [a flame spread rating of 25 or less and a smoke developed rating of 50 or less for [_____]] [and] [a flame spread rating of 75 or less and a smoke developed rating of 100 or less for
2.1.6.1 Structural Failure Test
ASTM E695 or ASTM D2394 for structural failure (drop penetration). ASTM E695 using a 27.2 kg 60 lb sand filled leather bag, resisting no less than 407 N-m 300 ft. lb. cumulative impact energy before failure or ASTM D2394 using
139.7 mm 5.5 inch hemispherical projectile resisting no less than 357 N-m 264 ft. lb. before failure. Provide test specimen stud spacing a minimum 406 mm 16 inch on center.
2.1.6.2 Indentation Test
ASTM D5420 or ASTM D1037 for indentation resistance. ASTM D5420 using a .907 kg 32 oz weight with a 16 mm 5/8 inch hemispherical impacting head dropped once 915 mm 3 feet creating not more than 3.5 mm 0.137 inch indentation or ASTM D1037 using no less than 213 kg 470 lb weight applied to the 11.13 mm
0.438 inch diameter ball to create not more than a 0.5 mm 0.0197 inch indentation depth.
] 2.1.7 Predecorated Gypsum Board
NOTE: Predecorated gypsum board is available only in 1200 mm 48 inch wide panels. Interior finish materials for exits, hospitals, individual rooms with capacity for 5 or more persons must have a flame spread rating of 25 or less and smoked developed rating of 50 or less. Interior finish materials for other locations must have flame spread rating of 75 or less and smoke developed rating of 100 or less. Flame spread rating greater than 75 and smoke developed rating greater than 100 are not permitted. Refer to UFC 3-600-01, "Fire Protection Engineering for Facilities," for further guidance on specifying flame spread and smoke developed ratings.
NOTE: If the optional phrase "as selected" is not used to designate a color (and pattern), insert a manufacturer's name and color (and pattern) designation in the blank and add the following to the end of this paragraph "The manufacturer's name and catalog designation are provided in order to describe the color (and pattern) desired. Other manufacturer's products having a similar color (and pattern) will be acceptable."
NOTE: Insert designations of rooms or areas in which different flame spread and smoke developed ratings are required.
SECTION 09 29 00 Page 16
ASTM C1396/C1396M , [regular] [Type X] gypsum board, 1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, with a decorative wall covering (Class I) [or coating (Class II)] applied in-plant by the gypsum board manufacturer. The color [and pattern] of wall covering shall be [_____] [as selected]. Provide [_____] color [and pattern] wall covering selected.
[Furnish gypsum board with square edges, and a slight bevel to produce a shallow vee joint. Wrap all coverings around edges.] Furnish a predecorated gypsum board with [a flame spread rating of 25 or less and a smoke developed rating of 50 or less for [_____]] [and] [a flame spread rating of 75 or less and a smoke developed rating of 100 or less for
2.1.8 Cementitious Backer Units
NOTE: For adhesive applied ceramic tile in wet areas (tubs, shower enclosures, saunas, steam rooms, gang shower rooms), specify only cementitious backer units.
In accordance with the Tile Council of America (TCA) Handbook.
2.1.9 Joint Treatment Materials
NOTE: VOCs may be emitted from taping compounds and finishes during the curing process.
ASTM C475/C475M. [Use all purpose joint and texturing compound containing inert fillers and natural binders, including lime compound. Pre-mixed compounds shall be free of antifreeze, vinyl adhesives, preservatives, biocides and other slow releasing compounds.]
2.1.9.1 Embedding Compound
Specifically formulated and manufactured for use in embedding tape at gypsum board joints and compatible with tape, substrate and fasteners.
2.1.9.2 Finishing or Topping Compound
Specifically formulated and manufactured for use as a finishing compound.
2.1.9.3 All-Purpose Compound
Specifically formulated and manufactured to serve as both a taping and a finishing compound and compatible with tape, substrate and fasteners.
2.1.9.4 Setting or Hardening Type Compound
Specifically formulated and manufactured for use with fiber glass mesh tape.
2.1.9.5 Joint Tape
Use cross-laminated, tapered edge, reinforced paper, or fiber glass mesh tape recommended by the manufacturer.
SECTION 09 29 00 Page 17
2.1.10 Fasteners
2.1.10.1 Nails
ASTM C514. [For predecorated gypsum board provide special nails with factory coated heads of color to match wall covering materials as recommended by the predecorated gypsum board manufacturer.]
2.1.10.2 Screws
ASTM C1002, Type "G", Type "S" or Type "W" steel drill screws for fastening gypsum board to gypsum board, wood framing members and steel framing members less than 0.84 mm 0.033 inch thick. ASTM C954 steel drill screws for fastening gypsum board to steel framing members 0.84 to 2.84 mm 0.033 to 0.112 inch thick. Provide cementitious backer unit screws with a polymer coating.
2.1.10.3 Staples
1.5 mm thick No. 16 USS gageflattened galvanized wire staples with 11.1 mm 7/16 inch wide crown outside measurement and divergent point for base ply of two-ply gypsum board application. Use as follows:
Length of Legs Thickness of Gypsum Board
28.6 mm 1-1/8 inches 12.7 mm 1/2 inch
31.8 mm 1-1/4 inches 15.9 mm 5/8 inch
2.1.11 Adhesives
Using interior low-VOC products contributes to the following LEED credit: EQ4. Include VOC submittal if pursuing this LEED credit. Coordinate with Section 01 33 29 LEED(tm) DOCUMENTATION. Designer must verify suitability, availability and adequate competition (including verification of bracketed VOCs included in this guide specification) before specifying product VOC requirements. Army projects shall specify bracketed LEED VOC option only if pursuing this LEED credit and allowing adhesive attachment.
Do not use adhesive containing benzene, carbon tetrachloride, or trichloroethylene.[ Adhesive shall contain…