Appendix_B_SABER_Specifications_Vol_02.pdf

PDF 2 MB Posted

Attached to
FY19-24 Davis-Monthan SABER Solicitation Federal contract opportunity
Solicitation number
FA487719RA017
Issued by
Department of the Air Force Air Combat Command

About this file

This document is an appendix to a solicitation for ceramic tile installation services at Davis-Monthan Air Force Base in Tucson, Arizona. It provides product specifications for various types of ceramic tile, setting beds, mortars, grouts, and adhesives that may be required to complete the project. Material requirements include porcelain, mosaic, quarry, and glass wall tiles; floor tiles suitable for commercial use; cementitious backer boards; reinforcing wire fabric; and setting compounds. The appendix specifies standards such as ANSI A137.1 and ASTM C373 for tile, as well as LEED documentation and submittal requirements. It also outlines installation procedures for walls, floors, and transition strips.

SOW Appendix B

View the file

Other files for this federal contract opportunity

Other files attached to FY19-24 Davis-Monthan SABER Solicitation, newest first.
File Type Posted
Attachment_4_Drawing_Cover_Sheet.pdf PDF
Conceptual_Sketch_A1.pdf PDF
Attachment_5_D_Size_Drawing_Sheet_Title_Block.pdf PDF
SABER_Re-Compete_Consolidated_RFI_Responses.pdf PDF
Attachment_2_Non_Pre-Priced_Item_Bid_Sheet.pdf PDF
04300-012-003.PDF PDF
04300-013-002.PDF PDF
04300-016-006.pdf PDF
2000-07_Air_Sampling.pdf PDF
Attachment_6_-_Past_Performance_Questionaire.docx DOCX document
04300-013-001.PDF PDF
Seed_Project_FBNV180044_Conceptual_Sketch_Drawing.pdf PDF
Contractor_Environmental_Guide_(15_May_2019).pdf PDF
GDN_AZ20190008_-_AZ08_-_Highway.pdf PDF
2003-04_Asbestos_Survey.pdf PDF
1998-06_Asbestos_Survey.pdf PDF
Attachment_1_SABER_Estimate_Cover_Sheet.pdf PDF
04300-011-001.PDF PDF
04300-013-003.PDF PDF
Appendix_C_SABER_Specifications_Vol_03.pdf PDF
Attachment_5_D_Size_Drawing_Sheet_Title_Block.dwg DWG drawing
2001-04_Asbestos_Survey.pdf PDF
04300-016-012.pdf PDF
04300-012-004.PDF PDF
04300-016-015.pdf PDF
1996-08_Asbestos_Survey.pdf PDF
GDN_AZ20190002_-_AZ02_-_Residential.pdf PDF
Solicitation_-_FA487719RA017.pdf PDF
04300-016-019.pdf PDF
04300-016-008.pdf PDF
2003-07_Air_Sampling.pdf PDF
Scanned_As_Built_Abatement_2004.pdf PDF
04300-016-005.pdf PDF
Base_Access_Request_-_Event_EAL.xls XLS spreadsheet
04300-016-002.pdf PDF
1996-05_Asbestos_Survey.pdf PDF
GDN_AZ20190006_-_AZ06_-_Heavy_Dams.pdf PDF
GDN_AZ20190018_-_AZ18_-_Heavy.pdf PDF
2001-08_Asbestos_Survey.pdf PDF
04300-013-005.PDF PDF
04300-016-018.pdf PDF
04300-014-001.PDF PDF
2001-10_Asbestos_Shipment.pdf PDF
2012-06_Asbestos_Survey.pdf PDF
04300-009-001.PDF PDF
04300-016-020.pdf PDF
04300-016-014.pdf PDF
2004-11_Asbestos_Survey.pdf PDF
1996-01-11_Asbestos_Survey.pdf PDF
04300-016-013.pdf PDF
Show all 50

FY19-24 Davis-Monthan SABER Solicitation has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPENDIX B

SPECIFICATIONS

(Volume 02)

FOR

SIMPLIFIED ACQUISITION

OF

BASE ENGINEER REQUIREMENTS

(SABER)

AT

DAVIS-MONTHAN AIR FORCE BASE

TUCSON, ARIZONA

11 February 2019

Table of Contents-1

TECHNICAL PROVISIONS OF SPECIFICATIONS

SABER Contract (Volume 02)

Contractor to furnish all labor, equipment, appliance and materials and perform all operations in connection with all Task Orders issued under the SABER contract at Davis-Monthan AFB, Arizona, in strict accordance with these specifications.

TABLE OF CONTENTS

SECTION AND TITLE

DIVISION 09 – FINISHES

09 24 23 Stucco

09 29 00 Gypsum Board

09 30 13 Ceramic Tiling

09 51 00 Acoustical Ceilings

09 65 00 Resilient Flooring

09 68 00 Carpeting

09 69 13 Rigid Grid Access Flooring

09 83 13 Acoustical Wall Treatment

09 90 00 Paints and Coatings

DIVISION 10 – SPECIALTIES

10 14 00.20 Interior Signage

10 21 13 Toilet Compartments

10 28 13 Toilet Accessories

DIVISION 12 – FURNISHINGS

12 36 00 Countertops

DIVISION 15 – MECHANICAL SYSTEMS

15121 Expansion Compensation

15140 Supports and Anchors

15190 Mechanical Identification

15241 Vibration Isolation

15242 Vibration Isolation

Table of Contents-2

15260 Domestic Water Piping Insulation

15261 Hydronic Piping Insulation

15280 Equipment Insulation

15290 Ductwork Insulation

15310 Fire Protection Piping

15311 Fire Hydrants

15325 Wet Pipe Sprinkler Systems

15410 Sanitary Sewer, Waste and Vent System

15411 Domestic Water System

15412 Natural Gas System

15413 Condensate and Equipment Drains

15414 Compressed Air System

15430 Plumbing Specialties

15440 Plumbing Fixtures

15445 Gas-Fired Water Heaters

15446 Electric Water Heaters

15450 Plumbing Equipment

15510 Hydronic Piping

15515 Hydronic Specialties

15540 HVAC Pumps

15556 Cast Iron Boilers

15575 Breechings, Chimneys & Stacks

15624 Make-Up Air Units

15682 Air Cooled Water Chillers

15684 Make-Up Air Units

15760 Air Conditioning Units (Packaged Gas Heating, Electric Cooling)

15761 Air Conditioning Units (Electric Heating, Electric Cooling)

15762 Air Conditioning Units (Electric Cooling Only)

15765 Bypass Variable Air Volume (VAV) System

15771 Roof Mounting Frame and Base (For Air Conditioning Units)

15835 Terminal Heat Transfer Units

15855 Air Handling Units with Coils

15860 Centrifugal Fans

Table of Contents-3

15865 Axial Fans

15870 Power Ventilators

15885 Air Cleaning

15886 High Velocity Dust Collection Systems

15890 Low Pressure Ductwork

15891 Medium and High Pressure Ductwork

15892 Fiberglass Ductwork

15893 Underground Ductwork

15910 Ductwork Accessories

15930 Pressure Independent Air Terminal Units

15931 Pressure Dependent Air Terminal Units

15936 Air Outlets and Inlets

15973 Pneumatic Control Systems

15975 Direct Digital Control Systems

15976 Variable Speed Controllers

15980 Instrumentation

15990 Testing, Adjusting, and Balancing

USACE / NAVFAC / AFCEC / NASA UFGS-09 24 23 (May 2009) Change 1 - 11/12 Preparing Activity: USACE Superseding UFGS-09 24 23 (April 2006)

UNIFIED FACILITIES GUIDE SPECIFICATIONS

References are in agreement with UMRL dated January 2015

SECTION TABLE OF CONTENTS

DIVISION 09 - FINISHES

SECTION 09 24 23

STUCCO

05/09

PART 1 GENERAL

1.1 REFERENCES

1.2 SUSTAINABILITY REPORTING

1.3 SUBMITTALS

1.4 QUALITY ASSURANCE

1.5 DELIVERY, STORAGE, AND HANDLING

1.6 ENVIRONMENTAL REQUIREMENTS

PART 2 PRODUCTS

2.1 PORTLAND CEMENT

2.2 COLORED STUCCO FINISH COAT

2.3 LIME

2.4 SAND

2.5 ACCESSORIES

2.6 STEEL FRAMING

2.7 METAL LATH

2.8 WATER

PART 3 EXECUTION

3.1 FRAMING

3.2 CONTROL JOINTS

3.3 LATH

3.3.1 Steel and Wood Supports

3.3.2 On Concrete and Masonry

3.3.3 Over Metal Lintels and Flashings

3.3.4 Special Shapes, Profiles, and Contours

3.4 FURRING

3.5 PREPARATION OF SURFACES

3.6 PROPORTIONS AND MIXING

3.7 STUCCO APPLICATION

3.7.1 Workmanship

3.7.2 Scratch Coat

SECTION 09 24 23 Page 1

3.7.3 Brown Coat

3.7.4 Finish Coat

3.7.5 Surface Tolerance

3.8 CURING AND PROTECTION

3.9 PATCHING AND POINTING

-- End of Section Table of Contents --

SECTION 09 24 23 Page 2

USACE / NAVFAC / AFCEC / NASA UFGS-09 24 23 (May 2009) Change 1 - 11/12 Preparing Activity: USACE Superseding UFGS-09 24 23 (April 2006)

UNIFIED FACILITIES GUIDE SPECIFICATIONS

References are in agreement with UMRL dated January 2015

SECTION 09 24 23

STUCCO

05/09

NOTE: This section covers requirements for stucco, including associated framing and lathing.

Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.

Remove information and requirements not required in respective project, whether or not brackets are present.

Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR) .

PART 1 GENERAL

1.1 REFERENCES

NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.

Use the Reference Wizard's Check Reference feature when you add a RID outside of the Section's Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizard's Check Reference feature to update the issue dates.

SECTION 09 24 23 Page 3

References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM A1064/A1064M (2014) Standard Specification for Carbon-Steel Wire and Welded Wire Reinforcement, Plain and Deformed, for Concrete

ASTM C1032 (2014) Standard Specification for Woven Wire Plaster Base

ASTM C1063 (2014d) Standard Practice for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster

ASTM C150/C150M (2012) Standard Specification for Portland Cement

ASTM C206 (2003; R 2009) Standard Specification for Finishing Hydrated Lime

ASTM C841 (2003; R 2013) Installation of Interior Lathing and Furring

ASTM C847 (2014a) Standard Specification for Metal Lath

ASTM C897 (2005; R 2014) Aggregate for Job-Mixed Portland Cement-Based Plasters

ASTM C926 (2014a) Application of Portland Cement-Based Plaster

ASTM C933 (2014) Welded Wire Lath

ASTM D1784 (2011) Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds

U.S. GREEN BUILDING COUNCIL (USGBC)

LEED BD+C (2009; R 2010) Leadership in Energy and Environmental Design(tm) Building Design and Construction (LEED-NC)

1.2 SUSTAINABILITY REPORTING

SECTION 09 24 23 Page 4

SECTION 09 24 23 Page 5

NOTE: The bracketed items are representative of LEED material documentation and requirements that may apply to this project. These items should be edited to reflect the project requirements.

Materials in this technical specification may contribute towards contract compliance with sustainability requirements. See Section 01 33 29 SUSTAINABILITY REPORTING for project LEED BD+C [local/ regional materials][ and ][recycled content] and LEED documentation requirements.

1.3 SUBMITTALS

NOTE: Review and edit the following list to reflect only the submittals required for the project.

Submittals should be kept to the minimum required for adequate quality control.

Government approval is required for all submittal items. The following shall be submitted in accordance with paragraph 1.4 of Section 01010, SUMMARY OF WORK:

SECTION 09 24 23 Page 6

1.3.1 Shop Drawings

Lath

1.3.2 Product Data

Proportions and Mixing

1.3.3 Samples

Colored Stucco Finish Coat Sample Panel

1.3.4 Closeout Submittals

LEED Documentation

1.4 QUALITY ASSURANCE

Submit, if required, a SAMPLE PANEL as follows: [One 300 mm 12 inch square stucco panel showing finish texture and color and exposed reinforcement at the edges, one 300 mm 12 inch square of reinforcement, and a 300 mm 12 inch length of each accessory proposed, prior to proceeding with stucco work.] [A sample panel of stucco, constructed at the jobsite, and located as directed, to demonstrate installation procedures, texture and color, prior to proceeding with any stucco work; panel size shall be a minimum of 1200 mm wide x 2400 mm 4 feet wide x 8 feet high; containing each type accessory proposed for use and constructed in the vertical position. Sample panel shall have exposed reinforcement at the edges. Each phase of installation such as framing, scratch coat, brown coat, finish coat and curing procedures shall be demonstrated in the construction of the panel. Submit one 300 mm 12 inch square of reinforcement and one 300 mm 12 inch length of each accessory proposed for use, prior to constructing the sample panel.]

1.5 DELIVERY, STORAGE, AND HANDLING

Deliver packaged materials to the site in the original packages and containers with labels intact and seals unbroken. Keep cementitious materials dry and stored off the ground, under cover and away from damp surfaces until ready to be used. Aggregate shall be covered to prevent the absorption or loss of moisture.

1.6 ENVIRONMENTAL REQUIREMENTS

Do not apply stucco when the ambient temperature is 4 degrees C 40 degrees F or lower, or when a drop in temperature below 4 degrees C 40 degrees F is expected within 48 hours after application.

PART 2 PRODUCTS

2.1 PORTLAND CEMENT

NOTE: Where colored or white stucco finish is required, the gray portland cement will be omitted.

Select type of cement to provide the required characteristics. Type I cement should normally be specified when stucco requires no special characteristics. Type II cement should be specified when stucco will be exposed to moderate sulphate (alkali) action. Type III cement should be specified when high early strength is needed.

Portland cement shall conform to ASTM C150/C150M, [gray portland cement Type [I] [II] [III].] [white portland cement, Type [I] [II] [III].]

2.2 COLORED STUCCO FINISH COAT

Colored stucco finish coat shall be a mill mixed product using white portland cement and requiring only the addition of and mixing with water for application. Color shall be [in accordance with Section 09 06 90COLOR SCHEDULE] [_____]. Submit samples including both a fabricated portion of unit of work and color samples.

2.3 LIME

Lime shall conform to ASTM C206, Type S.

2.4 SAND

Sand aggregate for job-mixed base coat and job-mixed finish coat stucco shall conform to ASTM C897.

2.5 ACCESSORIES

NOTE: Custom aluminum radiuses, and custom miters and intersections with welded corners or taped backs are available. Aluminum shapes with clear anodized, color anodized, or baked enamel finishes may be used where required for aesthetic purposes. Aluminum shapes are more costly than standard steel or PVC shapes.

Accessories shall be [roll formed galvanized steel, or rigid polyvinyl chloride (PVC)] [_____], except that cornerite and striplath shall be formed from steel sheets with manufacturer's standard galvanized coating.

Vinyl members shall be in accordance with ASTM D1784. Welded wire corner reinforcements shall be zinc coated, galvanized 1.4 mm 17 gauge steel wire conforming to ASTM A1064/A1064M . Furring shall include hangers, bolts, inserts, clips, fastenings, and attachments of number, size, and design to develop the full strength of the members.

2.6 STEEL FRAMING

NOTE: Stud sizes and framing dimensions and details will be indicated on the drawings. Framing will be designed for a maximum deflection of L/240 studs only assembly or a maximum deflection of L/360 for completed assembly, based on wind load design requirements in UFC 3-301-01.

SECTION 09 24 23 Page 7

Steel framing shall be as shown and shall be manufacturers standard products with shop applied protective coating.

2.7 METAL LATH

Metal lath shall conform to ASTM C847, types and weights in accordance with the various spacing shown in ASTM C841. Lath for vertical application on steel and wood framing supports shall be expanded metal or welded or woven wire and shall have paper backing with a minimum vapor permeance of 287.2 ng per Pa per second per square meter 5 perms. Woven wire lath shall be a maximum 38 x 38 mm 1-1/2 x 1-1/2 inch mesh wire of not less than 1.37 mm

0.0540 inch nominal diameter and shall conform to ASTM C1032. Welded wire lath shall conform to ASTM C933, with openings not to exceed 50 x 50 mm 2 x 2 inches. Expanded metal or wire lath shall be fabricated in a manner to provide not less than 6 mm 1/4 inch keying between wire and paper backing and keying shall be obtained by a uniform series of slots in a perforated face paper woven between the wires.

2.8 WATER

Provide clean, fresh, potable water, free from amounts of oils, acids, alkalis and organic matter that would be injurious to the stucco.

PART 3 EXECUTION

3.1 FRAMING

Framing shall be installed as indicated.

3.2 CONTROL JOINTS

NOTE: Control joints will be shown on the drawings, dividing the stucco into areas of not more than 13 square meters (144 square feet) with no dimension between control joints greater than 5.4 meters (18 feet). The length to width ratio of the area bounded by the control joints will not exceed 25 to 63 mm (1 to 2-1/2 inches).

Control joints shall be located as indicated on the drawings.

Prefabricated control joint members shall be installed prior to the application of the stucco. Control joints shall be cleared of all stucco within the control area after stucco application and prior to final stucco set.

3.3 LATH

NOTE: Drawings will clearly indicate where metal lath is required. Metal lath will be used over metal supports and wood supports. Metal reinforcement with water-resistant paper is recommended in all steel frame construction and suspended ceilings. The use of metal reinforcement over concrete and masonry will be in accordance with local practice based upon satisfactory experience.

Paper backed lath may be applied to interior

SECTION 09 24 23 Page 8 concrete and masonry when adequate and uniform bond cannot be obtained otherwise, and when the lath will be protected from moisture.

Install lath in accordance with ASTM C841 or ASTM C1063 except as otherwise specified. Metal and wire lath shall be applied straight, without buckles and with joints staggered. End laps of metal lath shall be not less than 25 mm 1 inch. When paper-backed lath is used, the paper shall be split from the lath at all lap areas to provide a paper to paper and lath to lath lap. Horizontal joints shall be shiplapped. Lath shall be interrupted at all control joints. Submit drawings showing details of construction for reinforcement, furring, and grounds; including manufacturer's installation instructions for stucco materials, and locations where each mix and coating thickness will be used.

3.3.1 Steel and Wood Supports

Apply metal lath over vertical open or solid wood and steel backing frame construction only after sheathing and air barrier has been applied to the area to receive the stucco. Fasten lath every 200 mm 8 inches vertically and every 400 mm 16 inches horizontally; and where sheets of lath are lapped. Drive fasteners to hold both lapped edges securely in place.

3.3.2 On Concrete and Masonry

Fasten lath every 200 mm 8 inches vertically and every 400 mm 16 inches horizontally. Where wood supports adjoin masonry or concrete in the same direction, provide casing bead, control joints, or reinforcement as indicated.

3.3.3 Over Metal Lintels and Flashings

Lath over metal lintels shall be extended vertically over the angles to a height of not less than 150 mm 6 inches and horizontally across the underside of the lintels and shall be secured in an approved manner. Lath over metal flashings shall lap the flashings not less than 50 mm 2 inches and shall be extended vertically for a height of not less than 150 mm 6 inches.

3.3.4 Special Shapes, Profiles, and Contours

Special shapes, profiles, and contours shall be formed with wood, metal or aluminum furring and reinforcing.

3.4 FURRING

Furring shall be installed to true lines and surfaces and shall be rigidly supported and secured in place.

3.5 PREPARATION OF SURFACES

Preparation of surfaces for application of stucco to solid bases such as stone, masonry or concrete shall conform to the applicable requirements of

ASTM C926.

3.6 PROPORTIONS AND MIXING

Proportions and mixing for job-mixed base coat and finish coat shall

SECTION 09 24 23 Page 9 conform to the applicable requirements of ASTM C926. Mixing of mill-mixed finish coat shall be in accordance with the manufacturer's directions.

Submit detailed description of the proposed job-mix proportions for base and finish coats; including identification of thickness of coats.

3.7 STUCCO APPLICATION

Stucco shall be applied in three coats to a thickness of not less than 25 mm 1 inch as measured from the back plane of metal reinforcement, exclusive of ribs or dimples or from the face of solid backing or support, with or without metal reinforcement, to the finished stucco surface, including moderate texture variations. Stucco application shall conform to the applicable requirements of ASTM C926 and the following:

3.7.1 Workmanship

Items or features of the work in connection with or adjoining the stucco shall be in place, plumb, straight, and true prior to beginning the stucco work. Metal and wire lath, where required, shall be in place and positioned to provide a good key at back of lath. Where lath is applied over copper, the copper shall be given a heavy coat of bituminous paint.

Masonry surfaces to receive stucco shall be evenly dampened immediately prior to application of stucco. Each stucco coat shall be applied continuously in one general direction, without allowing mortar to dry at edges. Where it is impossible to work the full dimension of a wall surface in a continuous operation, jointing shall be made at a break, opening, or other natural division of the surface. Edges to be joined shall be dampened slightly to produce a smooth confluence. Exterior corners of stucco shall be slightly rounded. Stucco on soffit surfaces shall be pitched forward to form a drip.

3.7.2 Scratch Coat

Apply scratch coat not less than 10 mm 3/8 inch thick under sufficient pressure to form good keys and to completely embed the reinforcement.

Before the scratch coat has set, it shall be lightly scratched in one direction and vertical surfaces shall be scratched in the horizontal direction only. The scratch coat shall be fog cured for a minimum of 72 hours.

3.7.3 Brown Coat

Evenly dampen the scratch coat to obtain uniform suction before the brown coat is applied. There shall be no visible water on the surface when the brown coat is applied. The brown coat shall be applied to the scratch coat with sufficient pressure to force the stucco into the scratches and shall be brought to a plumb, true, even plane with rod or straightedge. When set sufficiently, the brown coat shall be uniformly floated with a dry float to promote densification of the coat and to provide a surface receptive to bonding of the finish coat. Brown coat shall be fog cured for a minimum of 72 hours.

3.7.4 Finish Coat

Dampen surfaces of the brown coat not more than 1 hour before the finish coat is to be applied to a uniform wetness with no free-standing water on the surface. The finish coat shall have a [smooth trowel] [float] [trowel-textured] [rough-textured] [spray-textured] [exposed aggregate] finish and shall conform to the approved sample. Fog cure the finish coat

SECTION 09 24 23 Page 10 for a minimum of 48 hours. Take care to prevent staining.

3.7.5 Surface Tolerance

When a 3 m 10 foot straightedge is placed at any location on the finished surface of the stucco, excluding rough-textured finish, the surface shall not vary more than 3 mm 1/8 inch from the straightedge.

3.8 CURING AND PROTECTION

Perform fog curing by applying a fine mist of water to the stucco.

Exercise care during fog curing to avoid erosion damage of the stucco surfaces. Do not use a solid stream of water. Fognot less than three times daily. Protect the stucco from the direct rays of the sun during severe drying conditions using canvas, cloth or other approved sheet material.

3.9 PATCHING AND POINTING

Replace or patch loose, cracked, damaged or defective work as directed.

Patching shall match existing work in texture and color and shall be finished flush.

-- End of Section --

SECTION 09 24 23 Page 11

USACE / NAVFAC / AFCEC / NASA UFGS-09 29 00 (May 2011) Change 1 - 05/13 PREPARING ACTIVITY: NAVFAC Superseding UFGS-09 29 00 (August 2010)

UNIFIED FACILITIES GUIDE SPECIFICATIONS

References are in agreement with UMRL dated January 2015

SECTION TABLE OF CONTENTS

DIVISION 09 - FINISHES

SECTION 09 29 00

GYPSUM BOARD

05/11

PART 1 GENERAL

1.1 REFERENCES

1.2 SUBMITTALS

1.3 SUSTAINABLE DESIGN CERTIFICATION

1.4 DELIVERY, STORAGE, AND HANDLING

1.4.1 Delivery

1.4.2 Storage

1.4.3 Handling

1.5 ENVIRONMENTAL CONDITIONS

1.5.1 Temperature

1.5.2 Exposure to Weather

1.5.3 Temporary Ventilation

1.6 SUSTAINABLE DESIGN REQUIREMENTS

1.6.1 Local/Regional Materials

1.6.2 Environmental Data

1.7 QUALIFICATIONS

1.8 SCHEDULING

PART 2 PRODUCTS

2.1 MATERIALS

2.1.1 Gypsum Board

2.1.1.1 Regular

2.1.1.2 Foil-Backed

2.1.1.3 Type X (Special Fire-Resistant)

2.1.2 Gypsum Backing Board

2.1.2.1 Regular

2.1.2.2 Foil-Backed

2.1.2.3 Type X (Special Fire-Resistant)

2.1.3 Regular Water-Resistant Gypsum Backing Board

2.1.3.1 Regular

2.1.3.2 Type X (Special Fire-Resistant)

2.1.4 Glass Mat Water-Resistant Gypsum Tile Backing Board

2.1.4.1 Regular

SECTION 09 29 00 Page 1

2.1.4.2 Type X (Special Fire-Resistant)

2.1.5 Glass Mat Covered or Reinforced Gypsum Sheathing

2.1.5.1 Glass Mat Covered or Reinforced Gypsum Sheathing Sealant

2.1.6 Impact Resistant Gypsum Board

2.1.6.1 Structural Failure Test

2.1.6.2 Indentation Test

2.1.7 Predecorated Gypsum Board

2.1.8 Cementitious Backer Units

2.1.9 Joint Treatment Materials

2.1.9.1 Embedding Compound

2.1.9.2 Finishing or Topping Compound

2.1.9.3 All-Purpose Compound

2.1.9.4 Setting or Hardening Type Compound

2.1.9.5 Joint Tape

2.1.10 Fasteners

2.1.10.1 Nails

2.1.10.2 Screws

2.1.10.3 Staples

2.1.11 Adhesives

2.1.11.1 Adhesive for Fastening Gypsum Board to Metal Framing

2.1.11.2 Adhesive for Fastening Gypsum Board to Wood Framing

2.1.11.3 Adhesive for Laminating

2.1.12 Gypsum Studs

2.1.13 Shaftwall Liner Panel

2.1.14 Accessories

2.1.15 Asphalt Impregnated Building Felt

2.1.16 Water

PART 3 EXECUTION

3.1 EXAMINATION

3.1.1 Framing and Furring

3.1.2 [Gypsum Board] [and] [Framing]

3.1.3 [Masonry] [and] [Concrete] Walls

3.2 APPLICATION OF GYPSUM BOARD

3.2.1 Application of Single-Ply Gypsum Board to Wood Framing

3.2.2 Application of Two-Ply Gypsum Board to Wood Framing

3.2.3 Adhesive Nail-On Application to Wood Framing

3.2.4 Semi-Solid Gypsum Board Partitions

3.2.5 Solid Gypsum Board Partitions

3.2.6 Adhesive Application to Interior Masonry or Concrete Walls

3.2.7 Application of Gypsum Board to Steel Framing and Furring

3.2.8 Arches and Bending Radii

3.2.9 Gypsum Board for Wall Tile or Tile Base Applied with Adhesive

3.2.10 Exterior Application

3.2.11 Glass Mat Covered or Fiber Reinforced Gypsum Sheathing

3.2.12 Floating Interior Angles

3.2.13 Control Joints

3.2.14 Application of Foil-Backed Gypsum Board

3.2.15 Application of Predecorated Gypsum Board

3.2.16 Application of Impact Resistant Gypsum Board

3.3 APPLICATION OF CEMENTITIOUS BACKER UNITS

3.3.1 Application

3.3.2 Joint Treatment

3.4 FINISHING OF GYPSUM BOARD

3.4.1 Uniform Surface

3.4.2 Metal Trim for Predecorated Gypsum Board

3.5 SEALING

3.5.1 Sealing for Glass Mat or Reinforced Gypsum Board Sheathing

SECTION 09 29 00 Page 2

3.6 FIRE-RESISTANT ASSEMBLIES

3.7 PATCHING

3.8 SHAFTWALL FRAMING

3.9 WASTE MANAGEMENT

SECTION 09 29 00 Page 3

USACE / NAVFAC / AFCEC / NASA UFGS-09 29 00 (May 2011) Change 1 - 05/13 PREPARING ACTIVITY: NAVFAC Superseding UFGS-09 29 00 (August 2010)

UNIFIED FACILITIES GUIDE SPECIFICATIONS

References are in agreement with UMRL dated January 2015

SECTION 09 29 00

GYPSUM BOARD

05/11

NOTE: This guide specification includes the requirements for gypsum board, cementitious backer units, and accessories intended for use in drywall construction.

Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.

Remove information and requirements not required in respective project, whether or not brackets are present.

Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR) .

Reference Section 05 40 00 COLD-FORMED METAL FRAMING for load bearing studwork. Reference Section 09 22 00 SUPPORTS FOR PLASTER AND GYPSUM BOARD for non-loadbearing studs, furring and ceiling suspension systems.

NOTE: On the drawings, show:

1. Locations of each type of gypsum board, backing board and cementitious backer units, using same terminology as in the specification.

2. Locations and UL or GA design numbers for fire rated gypsum board and cementitious backer unit assemblies.

SECTION 09 29 00 Page 4

3. Locations of asphalt impregnated building felt if gypsum sheathing is used or if cementitious backer units are used in wet areas.

PART 1 GENERAL

1.1 REFERENCES

NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.

Use the Reference Wizard's Check Reference feature when you add a RID outside of the Section's Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizard's Check Reference feature to update the issue dates.

References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)

ANSI A108.11 (1992; Reaffirmed 2005) Specifications for Interior Installation of Cementitious Backer Units

ASTM INTERNATIONAL (ASTM)

ASTM C1002 (2014) Standard Specification for Steel Self-Piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs

ASTM C1047 (2014a) Standard Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base

ASTM C1177/C1177M (2013) Standard Specification for Glass Mat Gypsum Substrate for Use as Sheathing

ASTM C1178/C1178M (2013) Standard Specification for Glass Mat Water-Resistant Gypsum Backing Panel

ASTM C1396/C1396M (2014a) Standard Specification for Gypsum

SECTION 09 29 00 Page 5

Board

ASTM C1629/C1629M (2014a) Standard Classification for Abuse-Resistant Nondecorated Interior Gypsum Panel Products and Fiber-Reinforced Cement Panels

ASTM C475/C475M (2012; E 2014) Joint Compound and Joint Tape for Finishing Gypsum Board

ASTM C514 (2004; R 2014) Standard Specification for Nails for the Application of Gypsum Board

ASTM C557 (2003; E 2009; R 2009) Adhesives for Fastening Gypsum Wallboard to Wood Framing

ASTM C840 (2013) Application and Finishing of Gypsum Board

ASTM C954 (2011) Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from

0.033 in. (0.84 mm) to 0.112 in. (2.84 mm) in Thickness

ASTM D1037 (2012) Evaluating Properties of Wood-Base Fiber and Particle Panel Materials

ASTM D1149 (2007; R 2012) Standard Test Method for Rubber Deterioration - Surface Ozone Cracking in a Chamber

ASTM D226/D226M (2009) Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing

ASTM D2394 (2005; R 2011) Simulated Service Testing of Wood and Wood-Base Finish Flooring

ASTM D412 (2006a; R 2013) Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers - Tension

ASTM D5420 (2010) Impact Resistance of Flat, Rigid Plastic Specimen by Means of a Strike Impacted by a Falling Weight (Gardner Impact)

ASTM D624 (2000; R 2012) Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers

ASTM E2129 (2010) Standard Practice for Data Collection for Sustainability Assessment of Building Products

ASTM E695 (2003; R 2009) Measuring Relative Resistance of Wall, Floor, and Roof Construction to Impact Loading

SECTION 09 29 00 Page 6

SECTION 09 29 00 Page 7

ASTM E84 (2014) Standard Test Method for Surface Burning Characteristics of Building Materials

GYPSUM ASSOCIATION (GA)

GA 214 (2010) Recommended Levels of Gypsum Board Finish

GA 216 (2010) Application and Finishing of Gypsum Panel Products

GA 224 (2008) Installation of Predecorated Gypsum Board

GA 253 (2012) Application of Gypsum Sheathing

GA 600 (2009) Fire Resistance Design Manual

SCIENTIFIC CERTIFICATION SYSTEMS (SCS)

SCS Scientific Certification Systems (SCS)Indoor Advantage

U.S. GREEN BUILDING COUNCIL (USGBC)

LEED NC (2009) Leadership in Energy and Environmental Design(tm) New Construction Rating System

UL ENVIRONMENT (ULE)

ULE Greenguard UL Greenguard Certification Program

UNDERWRITERS LABORATORIES (UL)

UL Fire Resistance (2012) Fire Resistance Directory

1.2 SUBMITTALS

NOTE: Review and edit the following list to reflect only the submittals required for the project.

Submittals should be kept to the minimum required for adequate quality control.

SECTION 09 29 00 Page 8

Government approval is required for all submittal items. The following

SUMMARY OF WORK:

1.2.1 Product Data

Cementitious backer units

Glass Mat Water-Resistant Gypsum Tile Backing Board

Water-Resistant Gypsum Backing Board

Glass Mat Covered or Reinforced Gypsum Sheathing

Glass Mat Covered or Reinforced Gypsum Sheathing Sealant

Impact Resistant Gypsum Board

Accessories

Submit for each type of gypsum board and for cementitious backer units.

Certification

Gypsum Board; (LEED NC)

Submit documentation indicating percentage of post-industrial and post-consumer recycled content per unit of product. Indicate relative dollar value of recycled content products to total dollar value of products included in project.

Adhesives; (LEED NC)

SECTION 09 29 00 Page 9

Joint Treatment Materials

Submit manufacturer's product data, indicating VOC content.

Local/Regional Materials; (LEED NC)

Documentation indicating distance between manufacturing facility and the project site. Indicate distance of raw material origin from the project site. Indicate relative dollar value of local/regional materials to total dollar value of products included in project.

Environmental Data

1.2.2 Samples

Predecorated gypsum board

Submit for each color and pattern of predecorated gypsum board.

Where colors are not indicated, submit color selection samples of not less than eight of the manufacturer's standard colors.

1.2.3 Certificates

Asbestos Free Materials

Certify that gypsum board types, gypsum backing board types, cementitious backer units, and joint treating materials do not contain asbestos.

1.2.4 Manufacturer's Instructions

Material Safety Data Sheets

1.2.5 Operation and Maintenance Data

Manufacturer maintenance instructions

Waste Management

1.2.6 Closeout Submittals

Local/Regional Materials; (LEED)

LEED documentation relative to local/regional materials credit in accordance with LEED Reference Guide. Include in LEED Documentation Notebook.

Gypsum Board; (LEED)

LEED documentation relative to recycled content credit in accordance with LEED Reference Guide. Include in LEED Documentation Notebook.

Adhesives; (LEED)

LEED documentation relative to low emitting materials credit in accordance with LEED Reference Guide. Include in LEED Documentation Notebook.

1.3 [ SUSTAINABLE DESIGN CERTIFICATION

NOTE: Products meeting the Gold standard will also meet the basic standard. Require Gold when the facility will be used by people sensitive to air quality conditions, such as child development centers and medical facilties.

Product shall be third party certified in accordance with ULE Greenguard [ Gold], SCS Scientific Certification Systems Indoor Advantage[ Gold ]or equal. Certification shall be performed annually and shall be current.]

1.4 DELIVERY, STORAGE, AND HANDLING

1.4.1 Delivery

Deliver materials in the original packages, containers, or bundles with each bearing the brand name, applicable standard designation, and name of manufacturer, or supplier.

1.4.2 Storage

NOTE: Gypsum board provides a sink for adsorbing high short-term emissions of VOCs, formaldehyde, particulates, or other air-borne compounds.

Materials with high short-term emissions include, but are not limited to: adhesives, sealants and glazing compounds (specifically those with petrochemical vehicles or carriers); paint, wood preservatives, and finishes; control and/or expansion joint fillers; hard finishes requiring adhesive installation; gypsum board (with associated finish processes and products); and composite or engineered wood products with formaldehyde binders.

Keep materials dry by storing inside a sheltered building. Where necessary to store gypsum board and cementitious backer units outside, store off the ground, properly supported on a level platform, and protected from direct exposure to rain, snow, sunlight, and other extreme weather conditions.

Provide adequate ventilation to prevent condensation. Store per manufacturer's recommendations for allowable temperature and humidity range. Gypsum wallboard shall not be stored with materials which have high emissions of volatile organic compounds (VOCs) or other contaminants, including [_____]. Do not store panels near materials that may offgas or emit harmful fumes, such as kerosene heaters, fresh paint, or adhesives.

1.4.3 Handling

Neatly stack gypsum board and cementitious backer units flat to prevent sagging or damage to the edges, ends, and surfaces.

SECTION 09 29 00 Page 10

1.5 ENVIRONMENTAL CONDITIONS

1.5.1 Temperature

Maintain a uniform temperature of not less than 10 degrees C 50 degrees F in the structure for at least 48 hours prior to, during, and following the application of gypsum board, cementitious backer units, and joint treatment materials, or the bonding of adhesives.

1.5.2 Exposure to Weather

Protect gypsum board and cementitious backer unit products from direct exposure to rain, snow, sunlight, and other extreme weather conditions.

1.5.3 Temporary Ventilation

Provide temporary ventilation for work of this section.

1.6 SUSTAINABLE DESIGN REQUIREMENTS

1.6.1 Local/Regional Materials

NOTE: Using local materials can help minimize transportation impacts, including fossil fuel consumption, air pollution, and labor. Using materials harvested and manufactured within a 500 mile radius from the project site contributes to the following LEED credit: MR5. Coordinate with Section 01 33 29 LEED(tm) DOCUMENTATION. Use second option if Contractor is choosing local materials in accordance with Section 01 33 29 LEED(tm) DOCUMENTATION. First option shall not be used for USACE projects. Army projects shall include second option only if pursuing this LEED credit.

[Use materials or products extracted, harvested, or recovered, as well as manufactured, within a [800][_____] kilometer [500][_____] mile radius from the project site, if available from a minimum of three sources.][See Section 01 33 29 LEED(tm) DOCUMENTATION for cumulative total local material requirements. Gypsum board materials may be locally available.]

1.6.2 Environmental Data

NOTE: ASTM E2129 provides for detailed documentation of the sustainability aspects of products used in the project. This level of detail may be useful to the Contractor, Government, building occupants, or the public in assessing the sustainability of these products.

[Submit Table 1 of ASTM E2129 for the following products: [_____].]

1.7 QUALIFICATIONS

Furnish type of gypsum board work specialized by the installer with a

SECTION 09 29 00 Page 11 minimum of [3] [_____] years of documented successful experience.

1.8 SCHEDULING

NOTE: One or both of the following procedures shall be used to minimize the exposure of gypsum wallboard to materials or finishes which have high short-term emissions of VOCs, formaldehyde, particulates, or other air-borne compounds.

[The gypsum wallboard shall be taped, spackled and primed before the installation of the highly-emitting materials, including [_____].] [The gypsum wallboard shall be installed after the installation and ventilation period of the highly-emitting materials, including [_____].]

PART 2 PRODUCTS

2.1 MATERIALS

NOTE: Check ASTM C840, GA 216 and ANSI A108.11 for details of materials, fasteners, and application.

Conform to specifications, standards and requirements specified. Provide gypsum board types, gypsum backing board types, cementitious backing units, and joint treating materials manufactured from asbestos free materials only.

Submit Material Safety Data Sheets and manufacturer maintenance instructions for gypsum materials including adhesives.

2.1.1 Gypsum Board

Use of materials with recycled content, calculated on the basis of post-industrial and post-consumer percentage content, contributes to the following LEED credit: MR4. Designer must verify suitability, availability and adequate competition (including verification of bracketed percentages included in this guide specification) before specifying product recycled content requirements.

Use last option if Contractor is choosing recycled content products in accordance with Section 01 33 29 LEED(tm) DOCUMENTATION. Army projects shall specify recycled content only if pursuing this LEED credit

ASTM C1396/C1396M . [Gypsum board shall contain a minimum of [5][10][_____] percent post-consumer recycled content, or a minimum of [20][40][_____] percent post-industrial recycled content.] [Paper facings shall contain [100][_____] percent post-consumer recycled paper content. Gypsum cores shall contain a minimum of [95][_____] percent post-industrial recycled gypsum content.][See Section 01 33 29 LEED(tm) DOCUMENTATION for cumulative total recycled content requirements. Gypsum board may contain post-consumer or post-industrial recycled content.]

SECTION 09 29 00 Page 12

2.1.1.1 Regular

NOTE: Use tapered and featured edge gypsum board with embedding and finishing compounds when a very flat surface is required, such as long walls with lighting at the end of the wall and down or up lighted walls.

1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, [tapered][, tapered and featured] edges. [Provide tapered and featured edge gypsum board [in Rooms [_____] ] [as indicated].]

2.1.1.2 Foil-Backed

1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, [tapered] [tapered and featured] edges.

2.1.1.3 Type X (Special Fire-Resistant)

1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, [tapered] [tapered and featured] edges.

2.1.2 Gypsum Backing Board

NOTE: When thicker board is needed, replace the term "backing board" with "coreboard", and change dimension to 19.05 to 25.4 mm 3/4" to 1", depending on system used.

ASTM C1396/C1396M , gypsum backing board shall be used as a base in a multilayer system.

2.1.2.1 Regular

1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, square edges.

2.1.2.2 Foil-Backed

1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, square edges.

2.1.2.3 Type X (Special Fire-Resistant)

1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, square edges.

2.1.3 Regular Water-Resistant Gypsum Backing Board

NOTE: For adhesive applied ceramic tile in wet areas (tubs, shower enclosures, saunas, steam rooms, gang shower rooms, etc.), use cementitious backer units (Tile Council of America (TCA) Handbook) as a substrate. Specify ASTM C1396/C1396M or ASTM

SECTION 09 29 00 Page 13

C1178/C1178M for all other tiled areas including areas where only ceramic or quarry tile base is to be installed, and for ceilings in humid areas. When using water-resistant gypsum backing board at tile applications, the metal studs should not be spaced more than 406 mm 16 inches o.c. Specify moisture resistant gypsum board ASTM C1396/C1396M for humid areas that are not exposed to direct moisture.

When using moisture resistant board on ceilings, spacing of supports should be no more than 305 mm 12 inch on center.

NOTE: Additives used to produce water-resistant gypsum board ("green board") may include VOCs.

Water-resistant types may be difficult to recycle.

ASTM C1396/C1396M

2.1.3.1 Regular

1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, tapered edges.

2.1.3.2 Type X (Special Fire-Resistant)

1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, tapered edges.

2.1.4 Glass Mat Water-Resistant Gypsum Tile Backing Board

ASTM C1178/C1178M

2.1.4.1 Regular

1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, square edges.

2.1.4.2 Type X (Special Fire-Resistant)

1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, square edges.

2.1.5 [ Glass Mat Covered or Reinforced Gypsum Sheathing

NOTE: This section should be used where exterior gypsum sheathing with water resistance is required (i.e. cavity sheathing over metal studs with brick veneer or as substrate for EIFS systems). Always use asphalt impregnated felt paper for sheathing protection. For additional protection or if recommended by the manufacturer, choose the paragraph for sheathing sealant.

SECTION 09 29 00 Page 14

NOTE: Glass-fiber reinforced types may be difficult to recycle.

Exceeds physical properties of ASTM C1396/C1396M and ASTM C1177/C1177M .

Provide [12.7] [15.9,] mm [1/2][5/8] inch, gypsum sheathing. Provide gypsum board of with a noncombustible water-resistant core, with glass mat surfaces embedded to the gypsum core or reinforcing embedded throughout the gypsum core. Warrant gypsum sheathing board for at least twelve months against delamination due to direct weather exposure. Provide continuous, asphalt impregnated, building felt to cover exterior face of sheathing.

Seal [all joints, seams, and penetrations with compatible sealant.]

2.1.5.1 [ Glass Mat Covered or Reinforced Gypsum Sheathing Sealant

Provide sealant compatible with gypsum sheathing, rubber washers for masonry veneer anchors, and other associated cavity wall components such as anchors and through wall flashing. Provide sealants for gypsum sheathing board edge seams and veneer anchor penetrations recommended by the gypsum sheathing manufacturer and have the following performance requirements:

a. ASTM D412: Tensile Strength, 551 kilopascals 80 psi

b. ASTM D412: Ultimate Tensile Strength (maximum elongation), 1172 kilopascals 170 psi

c. ASTM D624: Tear Strength, dieB, 4.7 kN/m 27 ppi

d. ASTM D1149: Joint Movement Capability after 14 Days cure, plus or minus

50 percent.

] ] 2.1.6 [ Impact Resistant Gypsum Board

Note: Impact Resistant Gypsum Board Should Be Used When Abuse Or Vandalism Of Walls Is Anticipated And Gypsum Board Is The Only Wall Material Alternative Feasible. Consult Manufacture For Use Restrictions Of Impact Resistant Gypsum Board On Exterior Walls.

This Product Requires A Minimum Of 20 Gauge Metal Framing As Support, Coordinate with Section 09 22 00

SUPPORTS FOR PLASTER AND GYPSUM BOARD.

Some products rely on lexan backing for penetration resistance. The impervious layer will act as a vapor barrier which may not be desirable in certain wall systems and climates.

None of the paper faced gypsum products have high resistance to abrasion. Designer should consider high strength veneer plaster on wall systems using impact resistant gypsum wallboard, coordinate with Section 09 26 00 VENEER PLASTER.

1200 mm 48 inchwide, 15.9 mm 5/8 inch thick, tapered edges.

Reinforced gypsum panel with imbedded fiber mesh or lexan backing testing in accordance with the following tests. Hard body impact test must attain a Level 2 performance in accordance with ASTM C1629/C1629M . Provide fasteners that meet manufacturer requirements and specifications stated within this section. Impact resistant gypsum board, when tested in

SECTION 09 29 00 Page 15 accordance with ASTM E84, have [a flame spread rating of 25 or less and a smoke developed rating of 50 or less for [_____]] [and] [a flame spread rating of 75 or less and a smoke developed rating of 100 or less for

2.1.6.1 Structural Failure Test

ASTM E695 or ASTM D2394 for structural failure (drop penetration). ASTM E695 using a 27.2 kg 60 lb sand filled leather bag, resisting no less than 407 N-m 300 ft. lb. cumulative impact energy before failure or ASTM D2394 using

139.7 mm 5.5 inch hemispherical projectile resisting no less than 357 N-m 264 ft. lb. before failure. Provide test specimen stud spacing a minimum 406 mm 16 inch on center.

2.1.6.2 Indentation Test

ASTM D5420 or ASTM D1037 for indentation resistance. ASTM D5420 using a .907 kg 32 oz weight with a 16 mm 5/8 inch hemispherical impacting head dropped once 915 mm 3 feet creating not more than 3.5 mm 0.137 inch indentation or ASTM D1037 using no less than 213 kg 470 lb weight applied to the 11.13 mm

0.438 inch diameter ball to create not more than a 0.5 mm 0.0197 inch indentation depth.

] 2.1.7 Predecorated Gypsum Board

NOTE: Predecorated gypsum board is available only in 1200 mm 48 inch wide panels. Interior finish materials for exits, hospitals, individual rooms with capacity for 5 or more persons must have a flame spread rating of 25 or less and smoked developed rating of 50 or less. Interior finish materials for other locations must have flame spread rating of 75 or less and smoke developed rating of 100 or less. Flame spread rating greater than 75 and smoke developed rating greater than 100 are not permitted. Refer to UFC 3-600-01, "Fire Protection Engineering for Facilities," for further guidance on specifying flame spread and smoke developed ratings.

NOTE: If the optional phrase "as selected" is not used to designate a color (and pattern), insert a manufacturer's name and color (and pattern) designation in the blank and add the following to the end of this paragraph "The manufacturer's name and catalog designation are provided in order to describe the color (and pattern) desired. Other manufacturer's products having a similar color (and pattern) will be acceptable."

NOTE: Insert designations of rooms or areas in which different flame spread and smoke developed ratings are required.

SECTION 09 29 00 Page 16

ASTM C1396/C1396M , [regular] [Type X] gypsum board, 1200 mm 48 inch wide, [12.7] [15.9] mm [1/2] [5/8] inch thick, with a decorative wall covering (Class I) [or coating (Class II)] applied in-plant by the gypsum board manufacturer. The color [and pattern] of wall covering shall be [_____] [as selected]. Provide [_____] color [and pattern] wall covering selected.

[Furnish gypsum board with square edges, and a slight bevel to produce a shallow vee joint. Wrap all coverings around edges.] Furnish a predecorated gypsum board with [a flame spread rating of 25 or less and a smoke developed rating of 50 or less for [_____]] [and] [a flame spread rating of 75 or less and a smoke developed rating of 100 or less for

2.1.8 Cementitious Backer Units

NOTE: For adhesive applied ceramic tile in wet areas (tubs, shower enclosures, saunas, steam rooms, gang shower rooms), specify only cementitious backer units.

In accordance with the Tile Council of America (TCA) Handbook.

2.1.9 Joint Treatment Materials

NOTE: VOCs may be emitted from taping compounds and finishes during the curing process.

ASTM C475/C475M. [Use all purpose joint and texturing compound containing inert fillers and natural binders, including lime compound. Pre-mixed compounds shall be free of antifreeze, vinyl adhesives, preservatives, biocides and other slow releasing compounds.]

2.1.9.1 Embedding Compound

Specifically formulated and manufactured for use in embedding tape at gypsum board joints and compatible with tape, substrate and fasteners.

2.1.9.2 Finishing or Topping Compound

Specifically formulated and manufactured for use as a finishing compound.

2.1.9.3 All-Purpose Compound

Specifically formulated and manufactured to serve as both a taping and a finishing compound and compatible with tape, substrate and fasteners.

2.1.9.4 Setting or Hardening Type Compound

Specifically formulated and manufactured for use with fiber glass mesh tape.

2.1.9.5 Joint Tape

Use cross-laminated, tapered edge, reinforced paper, or fiber glass mesh tape recommended by the manufacturer.

SECTION 09 29 00 Page 17

2.1.10 Fasteners

2.1.10.1 Nails

ASTM C514. [For predecorated gypsum board provide special nails with factory coated heads of color to match wall covering materials as recommended by the predecorated gypsum board manufacturer.]

2.1.10.2 Screws

ASTM C1002, Type "G", Type "S" or Type "W" steel drill screws for fastening gypsum board to gypsum board, wood framing members and steel framing members less than 0.84 mm 0.033 inch thick. ASTM C954 steel drill screws for fastening gypsum board to steel framing members 0.84 to 2.84 mm 0.033 to 0.112 inch thick. Provide cementitious backer unit screws with a polymer coating.

2.1.10.3 Staples

1.5 mm thick No. 16 USS gageflattened galvanized wire staples with 11.1 mm 7/16 inch wide crown outside measurement and divergent point for base ply of two-ply gypsum board application. Use as follows:

Length of Legs Thickness of Gypsum Board

28.6 mm 1-1/8 inches 12.7 mm 1/2 inch

31.8 mm 1-1/4 inches 15.9 mm 5/8 inch

2.1.11 Adhesives

Using interior low-VOC products contributes to the following LEED credit: EQ4. Include VOC submittal if pursuing this LEED credit. Coordinate with Section 01 33 29 LEED(tm) DOCUMENTATION. Designer must verify suitability, availability and adequate competition (including verification of bracketed VOCs included in this guide specification) before specifying product VOC requirements. Army projects shall specify bracketed LEED VOC option only if pursuing this LEED credit and allowing adhesive attachment.

Do not use adhesive containing benzene, carbon tetrachloride, or trichloroethylene.[ Adhesive shall contain…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .