INSIDE CHANNEL PLATE
"x2"x2"
OUTSIDE CHANNEL PLATE
"x2"x3"
4" STANDARD PANEL DEPTH
1" x
" CLOSED CELL GASKET
(COMPRESSES TO LESS THAN 1/16")
" TAPCON, EMBED 2
" MIN. (TYP.)
#12 HEX HEAD SHEET METAL SCREWS
(EACH SIDE)
" TAPCON, EMBED 2
" MIN.
NEW CONCRETE SLAB BY OTHERS
EXTERIOR SURFACES OF PANELS AND
CHANNEL PLATES ARE COATED WITH
FIBERTECH F50 PENETRATING-PRIMER
(FIELD APPLIED) FOLLOWED BY FIBERTECH
F51 SEALER-COAT (FIELD APPLIED).
4" STEEL TUBE COLUMN
" x 2
" CHANNEL RAIL
END COLUMN BASE PLATE
" SIMPSON TITEN HD SCREW ANCHOR,
EMBED 3" MIN.
1'
CAULK
" 20 GA. COUNTERFLASHING
HIGH BOND TAPE
6"8"
(1) #12 SCREW AT CENTER
(4) #12 SCREWS AT EACH END
INSIDE AND OUTSIDE CHANNEL PLATE
4"
" TAPCON SCREWS. EMBED 2
" MIN.
SCREW AND TAPCON PATTERN
(INSIDE AND OUTSIDE)
NOTES:
1) BUILDING FLOOR LEVEL SPECIFICATION FOR THE CHANNEL PLATE FOOTPRINT ONLY - FROM THE CENTERLINE OF THE CHANNEL TROUGH, AN AREA OF THE BUILDING FLOOR EQUAL TO EIGHTEEN
INCHES WIDE (18" WIDE), NINE INCHES (9") TO EITHER SIDE OF THE CENTERLINE, AND AS LONG AS THE LENGTH OF ALL ASSEMBLED iGUARD ARMOR WALL PANELS™, NOT TO EXCEED
" OVER 8'. IF
DETERMINED AT THE TIME OF THE SITE SURVEY THAT THE DESIGNATED FLOOR AREA IS NOT WITHIN THESE SPECIFIED TOLERANCES AND PRE-INSTALLATION FLOOR PREPARATION WORK IS REQUIRED, THIS WORK CAN BE PROVIDED BY iFORTRESS OR OTHERS AT AN ADDITIONAL COST
2) IF LEVEL OF THE EXISTING FLOOR WITHIN THE CHANNEL TROUGH IS NOT WITHIN iFORTRESS' LEVEL TOLERANCE (NOT TO EXCEED 1/4" VARIATION PER OVERALL ASSEMBLED WALL LENGTH), A SELF
LEVELER, SUCH AS QUICKCRETE CAN BE ADDED WITHIN THE 4" SPACE BETWEEN THE CHANNEL PLATES ONLY. THIS COULD EFFECT FINAL DOOR SILL HEIGHT.
3) TAPCON CONCRETE SCREWS ATTACH CHANNEL PLATES TO EXISTING FLOOR SLAB UTILIZING THE PRE-EXISTING HOLES MANUFACTURED IN THE CHANNEL PLATES.
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
WALL PANEL TO SLAB
DETAIL
D.12
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF
DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A
GOVERNMENT CONTRACT, DETERMINED DECEMBER 5, 2017. OTHER REQUESTS
FOR THIS DOCUMENT SHALL BE REFERRED TO USAF AFMC AFLCMC/WNS.
6'
6'
6'6'
3 3
GROUND
TEST
WELL
1'-5.5"
CONCRETE
SLAB
OUTSIDE
BUILDING
WALL
23'
ELECTRIC SERVICE
CONDUIT
1'-5.5"
ELECTRIC SERVICE
GROUNDING CONDUIT
23'-7"
SECTION 'A'
SECTION 'B'
1" GALVANIZED
RIGID STEEL
1" iCOUSTIC PANEL
4" WALL PANEL
OUTSIDE
BUILDING
WALL
CONCRETE SLAB
(1) 1" GALVANIZED RIGID
STEEL CONDUIT
3'
2'
1'-5.5"
GROUNDING TEST
WELL
1'-5.5"
(1) 4" AND (1) 1" GALVANIZED RIGID STEEL
CONDUITS
6'
3'
(1) 4" AND (1) 1" GALVANIZED
RIGID STEEL CONDUITS
10"
OUTSIDE
BUILDING
WALL
CONCRETE SLAB
1" iCOUSTIC PANEL
4" WALL PANEL
1 ELECTRICAL FOUNDATION PLAN
2 ELECTRICAL GROUNDING DETAIL
3 GROUNDING TEST WELL DETAIL
4 CONDUIT FOUNDATION PLAN
4 CONDUIT FOUNDATION SECTION A4 CONDUIT FOUNDATION SECTION B
10'
MANHOLE
1'-7"
4"
CONCRETE
SLAB
OUTSIDE
BUILDING
WALL
SECTION 'A'
COMMUNICATION
CONDUITS
10'
CONCRETE SIGNAL
MANHOLE
(2) 2"
SCHEDULE 40 PVC
CONDUITS
1" iCOUSTIC PANEL
4" WALL PANEL
OUTSIDE
BUILDING
WALL
CONCRETE SLAB
1'-7" 3'
10'
(2) 2" SCHEDULE 40
PVC CONDUITS
1 COMMUNICATIOS FOUNDATION PLAN
2 CONDUIT FOUNDATION PLAN
3 CONDUIT FOUNDATION SECTION A
| 3.0 USAF JTC-TRS-RSS Concrete Pad (373765-S.01) 20171213 19 |
| 373765-E101-121117 |
| 373765-E102-121117 |
| 373765-S2.01-121117 |
| 373765-S2.02-121117 |