2.0_Structure_(373765-S.01)__20171213.pdf

PDF 4 MB Posted

Attached to
SOF Construct Pad Federal contract opportunity
Solicitation number
FA4855-18-R-0013
Issued by
Department of the Air Force Special Operations Command

About this file

Structure

View the file

Other files for this federal contract opportunity

Other files attached to SOF Construct Pad, newest first.
File Type Posted
FA4855-18-R-0013-0002_Solicitation_Amendment_2.pdf PDF
SOW_-_CZQZ_17-0014_SOF_Costruct_PAD_Rev._2.pdf PDF
Q&A.docx DOCX document
FA4855-18-R-0013_Rev._2_conformed_copy.pdf PDF
DBA_Wage_Determination_NM180023.pdf PDF
Amend_1.pdf PDF
Attachment_3_-_SOMS_-_CZQZ170014_-_SOF_Construct_PAD_For_Train_Sim.pdf PDF
2.1_Truss_System_(373765-S1.01)_20171213.pdf PDF
Attachment_4_-_One_Line_Electrical_Source.pdf PDF
Attachment_6_-_CAFB_and_Melrose_AFR_Civilian_Contractor_Environment_Guide_2015.pdf PDF
8.0_IDS_(373765-E104)_Updated-20171213.pdf PDF
Attachment_5_-_COMM_Inputs.pdf PDF
7.0_Fire_AlarmSupression_(373765-FA1.1)_Update-20171128.pdf PDF
Attachment_9_-_CAFB_Sustainable_Landscape_Development_Plan__2012.pdf PDF
FA4855-18-R-0013.pdf PDF
6.0_Electrical_(373765-E.000)_Updated-20171213.pdf PDF
1.0_Floorplan_(373765-S1.01)_20171213.pdf PDF
5.0_COM_(373765-C.101)_Updated-20171213.pdf PDF
3.0_Concrete_Pad_(373765-S.01)__20171213.pdf PDF
Attachment_8_-_CAFB_Electrical_Standards__2014.pdf PDF
4.0_Mechanical_(373765-H.101)_20171213.pdf PDF
Attachment_2_-_SPECIFICATIONS_-_CZQZ_17-0014_SOF.pdf PDF
2.2_Structure_(373765)_StructuralCalculations.pdf PDF
Attachment_7_-_CAFB_Architectural_Compatibility_Guide_2012.pdf PDF
Show all 24

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10'

[3.048 m]

10'

[3.048 m]

10'

[3.048 m]

8'

[2.438 m]

46'

[14.021 m]

26'

[7.925 m]

BACK

FRONT

RIGHT SIDE

LEFT SIDE

8'

[2.438 m]

MC6x15.1 CHANNEL

AROUND

PERIMETER OF

ROOM AND AT TOP

OF END WALLS

VESTIBULE

CONFERENCE

ROOM

SIMULATOR ROOM

iVENT

10"X10"

6" UPPER PORTAL

iVENT

8"X8"

9" LOWER PORTAL

6" UPPER PORTAL

12" UPPER PORTAL

6" UPPER PORTAL

iVENT

16"X8"

9" UPPER PORTAL

6" UPPER PORTAL

6" UPPER PORTAL

6" UPPER PORTAL

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

CUSTOMER TO CHECK

EXTERIOR COLOR OF MCF SERIES iFORTRESS™:BLACK COC. GROVE

(SELECT ONE)

_______BLACK _______COCONUT GROVE _______OTHER

(STANDARD) (STANDARD) (SPECIAL)

NOTE: THE EXTERIOR AND INTERIOR SURFACES OF THE iPASSAGE DOOR

SYSTEM™, AS WELL AS THE INTERIOR OF ALL PANELS, ARE FINISHED IN WHITE

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

WALL PANEL LAYOUT

S.01

NOTES:

BUILDING FLOOR LEVEL SPECIFICATION FOR THE CHANNEL PLATE FOOT PRINT ONLY - FROM THE CENTERLINE OF THE

CHANNEL TROUGH, AN AREA OF THE BUILDING FLOOR EQUAL TO EIGHTEEN INCHES WIDE (18" WIDE), NINE INCHES (9")

TO EITHER SIDE OF THE CENTERLINE, AND AS LONG AS THE LENGTH OF ALL ASSEMBLED iGUARD ARMOR WALL

PANELS™, NOT TO EXCEED

" OVER 8'. IF DETERMINED AT THE TIME OF THE SITE SURVEY THAT THE DESIGNATED

FLOOR AREA IS NOT WITHIN THESE SPECIFIED TOLERANCES AND PRE-INSTALLATION FLOOR PREPARATION WORK IS

REQUIRED, THIS WORK CAN BE PROVIDED BY iFORTRESS OR OTHERS AT AN ADDITIONAL COST - SHEET D.12 FOR WALL

PANEL TO SLAB DETAIL

*PORTAL PANEL LOCATION AND PORTAL DESIGNATIONS (HIGH OR LOW) MUST BE NOTED ON FINAL SIGNED DRAWINGS.

PLAN NORTH, SOUTH, EAST IS FOR INSTALLATION PURPOSES ONLY AND DOES NOT INDICATE TRUE CARDINAL

DIRECTIONS.

SEE SHEET S.06 FOR DOOR PANEL DETAIL, SHEET D.04 FOR CAMPORT DETAIL, SHEET D.05 FOR WALL PANEL DETAIL, SHEETS D.06, D.07 & D.08 FOR PORTAL PANEL DETAIL, SHEET D.09 FOR WALL PANEL CONNECTION AND FINISH DETAIL, D.11 FOR U-STRUT MOUNTING DETAIL AND SHEET D.13 FOR WALL PANEL TO SLAB DETAIL

DUE TO THE INSTALLATION OF PERIMETER OR END COLUMNS, THE INSTALLATION OF THE INSIDE CHANNEL PLATES IS

NOT CONTINUOUS. THEREFORE, INSIDE CHANNEL PLATES ARE TO BE CUT IN THE FIELD TO LENGTHS THAT ARE EQUAL

TO THE DISTANCES BETWEEN END COLUMN BASES.

INSTALLATION ABBREVIATIONS:

PD - PRIMARY DOOR

SD - SECONDARY DOOR

PC - PRIMARY CORNER

SC - SECONDARY CORNER

TC - TERTIARY CORNER

AC - ANCILLARY CORNER

QUANTITYHEIGHT

TOTAL QUANTITY OF WALL PANELS = 190

PANEL TYPE SYMBOL

DL118500DMF-E

DR118500DMF-E

DH961900DMF-E

DH721900MF

DL178500MF 1

DR178500MF

DL118600STC

DR118600STC

DH961900STC

PART NUMBER SYSTEM

(PNS)

COLORS

ALL COLUMNS, JOISTS AND CROSS BRACING ARE BLACK IN SIMULATOR ROOM AND

CONFERENCE ROOM.

ALL COLUMNS, JOISTS AND CROSS BRACING ARE WHITE IN VESTIBULE

SIMULATOR ROOM TO RECEIVE BLACK iCOUSTIC PANELS ON WALLS AND CEILING.

CONFERENCE ROOM TO RECEIVE iCOUSTIC PANELS ON WALLS AND CEILING - COLOR TO

BE SILVER NEUTRAL.

VESTIBULE - iFORTRESS PANELS FINISHED IN HIGH REFLECTANCE WHITE (NO iCOUSTIC

PANELS)

W88STD 64

W06STDS 63

W066HPS 2

W069LPS 1

W88ROC 4

W88FER-CO 2

W88FEL-CO 1

W88LOC 4

W06FERS-CO 2

W06FELS-CO 1

W06ROCS 4

W06LOCS 4

W06M1010HxxxS 1

W06M1010HxxxS 1

W88STD-FLT 9

W06STDS-FLT 9

W88FEL-15 1

W06FELS-15 1

W066HPS-FLT 4

W069HPS-FLT 1

W063HPS-FLT 1

W06M1608HxxxS-FLT 1

DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF

DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A

GOVERNMENT CONTRACT, DETERMINED DECEMBER 5, 2017. OTHER REQUESTS

FOR THIS DOCUMENT SHALL BE REFERRED TO USAF AFMC AFLCMC/WNS.

46'

[14.021 m]

10'

[3.048 m]

10'

[3.048 m]

8'

[2.438 m]

10'

[3.048 m]

8'

[2.438 m]

TC

FRONT

BACK

LEFT SIDE

SC PC

26'

[7.928 m]

RIGHT SIDE

AC

C8TGGS C8TEGTC0TGGT C0TGGT C0TGGT

C8TGGS C8TEGT

C8TEGT

C8TEGT

C8TEGT

C8TEGT

C8TEGT

C8TEGT

C8TEET

C8SEGT

C8TGGS

C8TGGS

C8TGGS

C8TGGS

C8TGGS

C8TGGS

C8TGES

C8SGGS

C0TGGT

C0SGGT

C0TGGT

C0TGGT

C0TGGT

C0TGGT

C0TGGT

C0TGGT

C0TGET

C0TGGT

C0SGGT

C0TGGT

C0TGGT

C0TGGT

C0TGGT

C0TGGT

C0TGGT

C0TGET

C0TGGT

C0SGGT

C0TGGT

C0TGGT

C0TGGT

C0TGGT

C0TGGT

C0TGGT

C0TGET

C8TGGS C8TEGTC0TGGT C0TGGT C0TGGT

C8TGGS C8TEGTC0TGGT C0TGGT C0TGGT

C8TGGS C8TEGTC0TGGT C0TGGT C0TGGT

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

CEILING PANEL LAYOUT

S.02

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

INSTALLATION ABBREVIATIONS:

PD - PRIMARY DOOR

SD - SECONDARY DOOR

PC - PRIMARY CORNER

SC - SECONDARY CORNER

TC - TERTIARY CORNER

AC - ANCILLARY CORNER

NOTES:

SEE SHEET D.03 FOR CAMPORT DETAIL, SHEET D.09 FOR WALL PANEL CONNECTION AND FINISH DETAIL, SHEET D.10 FOR CEILING PANEL

CONNECTION AND FINISH DETAIL, D.11 FOR U-STRUT MOUNTING DETAIL AND SHEET D.13 FOR ROOF DETAIL.

CEILING PANEL LEGEND

T: TONGUE

G: GROOVE

E: ENDER

S: STARTER

X: SPECIAL

PART NUMBER SYSTEM (PNS) QUANTITYLENGTH

TOTAL QUANTITY OF CEILING PANELS = 65

CEILING PANELS

3C0SGGT 10' [3.048 m]

33C0TGGT

11C8TEGT

3C0TGET

1C8TEET

1C8SEGT 8' [2.438 m]

10' [3.048 m]

10' [3.048 m]

C8TGES 1

C8TGGS 11

C8SGGS 18' [2.438 m]

8' [2.438 m]

8' [2.438 m]

8' [2.438 m]

8' [2.438 m]

DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF

DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A

26'

[7.823 m]

BACK

FRONT

LEFT SIDE

OUTLINE OF WALL PANELS

RIGHT SIDE

NOTES:

BUILDING FLOOR LEVEL SPECIFICATION - FROM THE CENTERLINE OF THE CHANNEL TROUGH, AN AREA OF THE BUILDING

FLOOR EQUAL TO EIGHTEEN INCHES WIDE (18" WIDE), NINE INCHES (9") TO EITHER SIDE OF THE CENTERLINE, AND AS LONG

AS THE LENGTH OF ALL ASSEMBLED iGUARD ARMOR WALL PANELS™, NOT TO EXCEED

" OVER 8'. IF DETERMINED AT THE

TIME OF THE SITE SURVEY THAT THE DESIGNATED FLOOR AREA IS NOT WITHIN THESE SPECIFIED TOLERANCES AND

PRE-INSTALLATION FLOOR PREPARATION WORK IS REQUIRED, THIS WORK CAN BE PROVIDED BY iFORTRESS OR OTHERS AT

AN ADDITIONAL COST - SHEET D.12 FOR WALL PANEL TO SLAB DETAIL

DUE TO THE INSTALLATION OF PERIMETER OR END COLUMNS, THE INSTALLATION OF THE INSIDE CHANNEL PLATES IS NOT

CONTINUOUS. THEREFORE, INSIDE CHANNEL PLATES ARE TO BE CUT IN THE FIELD TO LENGTHS THAT ARE EQUAL TO THE

DISTANCES BETWEEN END COLUMN BASES.

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

CHANNEL PLATE LAYOUT

S.03

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

INSTALLATION ABBREVIATIONS:

PD - PRIMARY DOOR

SD - SECONDARY DOOR

PC - PRIMARY CORNER

SC - SECONDARY CORNER

TC - TERTIARY CORNER

AC - ANCILLARY CORNER

PART NUMBER SYSTEM (PNS) QUANTITY

TOTAL LINEAR FEET = 649.33 FT [197.916 m]

CHANNEL PLATES

CHOSTD

CHOOCR-SPL2 4

LENGTH

28 in [0.711 m]

TYPE

INSIDE

OUTSIDE

TOTAL QUANTITY = 68

CHISTD-SPL2

4120 in [3.048 m] INSIDE

CHOSTD-SPL2 16120 in [3.048 m] OUTSIDE

CHISTD 28120 in [3.048 m] INSIDE

120 in [3.048 m]

DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF

DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A

26'

[7.925 m]

BACK

FRONT

LEFT SIDE

OUTLINE OF WALL PANELS

RIGHT SIDE

MC6x15.1 CHANNEL

AROUND

PERIMETER OF

ROOM AND AT TOP

OF END WALLS

10.0"

8.0"

1.5"

6.5"

1.5"

TYP

1/2" BASE PLATE OF END COLUMN

N.T.S.

4.0"

4.0"

6.0"

6.0"

1.0"

TYP

BASE PLATE OF CORNER COLUMN

N.T.S.

4.0"

4.0"

6.0"

16.0"

3.0"

1.0"

TYP

4.5"

TYP

5/8" CAP PLATE OF END COLUMN

N.T.S.

5/8" CAP PLATE OF MIDDLE COLUMN

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

COLUMN AND JOIST LAYOUT

S.04

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

NOTES:

BUILDING FLOOR LEVEL SPECIFICATION FOR CHANNEL PLATE FOOTPRINT ONLY - FROM THE CENTERLINE OF THE CHANNEL TROUGH, AN AREA OF THE

BUILDING FLOOR EQUAL TO EIGHTEEN INCHES WIDE (18" WIDE), NINE INCHES (9") TO EITHER SIDE OF THE CENTERLINE, AND AS LONG AS THE LENGTH

OF ALL ASSEMBLED iGUARD ARMOR WALL PANELS™, NOT TO EXCEED

" OVER 8'. IF DETERMINED AT THE TIME OF THE SITE SURVEY THAT THE

DESIGNATED FLOOR AREA IS NOT WITHIN THESE SPECIFIED TOLERANCES AND PRE-INSTALLATION FLOOR PREPARATION WORK IS REQUIRED, THIS

WORK CAN BE PROVIDED BY iFORTRESS OR OTHERS AT AN ADDITIONAL COST - SHEET D.12 FOR WALL PANEL TO SLAB DETAIL

DUE TO THE INSTALLATION OF PERIMETER OR END COLUMNS, THE INSTALLATION OF THE INSIDE CHANNEL PLATES IS NOT CONTINUOUS. THEREFORE, INSIDE CHANNEL PLATES ARE TO BE CUT IN THE FIELD TO LENGTHS THAT ARE EQUAL TO THE DISTANCES BETWEEN END COLUMN BASES.

INSTALLATION ABBREVIATIONS:

PD - PRIMARY DOOR

SD - SECONDARY DOOR

PC - PRIMARY CORNER

SC - SECONDARY CORNER

TC - TERTIARY CORNER

AC - ANCILLARY CORNER

PART NUMBER SYSTEM (PNS) QUANTITYLENGTH

TOTAL QUANTITY OF COLUMNS = 16

COLUMNS AND JOISTS

CLE173-B 14'-5" [4.450 m] 6

6J14304 25'-3 1/2" [7.708 m]

TYPE

14" JOIST - FINISH: BLACK

TOTAL QUANTITY OF JOISTS = 10

LEGEND

END COLUMN

CORNER COLUMN

JOIST

CHANNEL BRACE - FINISH: BLACK

CHANNEL BRACE - FINISH: WHITE

14" JOIST - FINISH: BLACK

14" JOIST - FINISH: BLACK

J14120

J14180

9'-11 1/2" [3.048 m]

14'-11 1/2" [4.572 m]

CLEW176-B 14'-8" [4.470 m] 1

CLE173-W 414'-5" [4.450 m]

CLC176-W 2

CLC176-B 2

CLEW176-W 114'-8" [4.470 m]

14'-8" [4.470 m]

14'-8" [4.470 m]

CBM116-B

CBM116-W

49'-8" [2.946 m]

29'-8" [2.946 m]

CHANNEL BRACE - FINISH: BLACKCBM086A-B

CBM086B-B

CHANNEL BRACE - FINISH: WHITE

CHANNEL BRACE - FINISH: BLACKCBM146A-B 212'-2" [3.708 m]

CHANNEL BRACE - FINISH: WHITE

CHANNEL BRACE - FINISH: BLACK

CBM086A-W

CBM086B-W

7'-2" [2.184 m]

7'-2" [2.184 m]

7'-2" [2.184 m]

7'-2" [2.184 m]

CHANNEL BRACE - FINISH: BLACKCBM146B-B 12'-2" [3.708 m]

CHANNEL BRACE - FINISH: WHITECBM146A-W 212'-2" [3.708 m]

2CHANNEL BRACE - FINISH: WHITECBM146B-W 12'-2" [3.708 m]

1CHANNEL BRACE - FINISH: WHITECBM304 25-4" [7.722 m]

1CHANNEL BRACE - FINISH: WHITECBM026 2'-2" [0.660 m]

1CHANNEL BRACE - FINISH: WHITECBM090 7'-6" [2.286 m]

DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF

DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A

FINISHED COLUMN

4" X 4"

14" J14304

DOUBLE JOIST

CEILING PANELS

4"

15'

OUTSIDE

CHANNEL PLATE

14'-8"

COLUMN BASE PLATE

FLOOR SLAB SPEC

F90

14"

INSIDE CHANNEL PLATE

13'-6"

8'-8"

6'

MC6x15.1 CHANNEL

12"

8" iCOUSTIC PANEL

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

ASSEMBLY INSIDE AND

OUTSIDE DIMENSIONS

S.05

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

NOTES:

BUILDING FLOOR LEVEL SPECIFICATION FOR THE CHANNEL PLATE FOOTPRINT ONLY - FROM THE CENTERLINE OF THE CHANNEL TROUGH, AN AREA OF THE BUILDING FLOOR EQUAL TO EIGHTEEN INCHES

WIDE (18" WIDE), NINE INCHES (9") TO EITHER SIDE OF THE CENTERLINE, AND AS LONG AS THE LENGTH OF ALL ASSEMBLED iGUARD ARMOR WALL PANELS™, NOT TO EXCEED

" OVER 8'. IF DETERMINED AT

THE TIME OF THE SITE SURVEY THAT THE DESIGNATED FLOOR AREA IS NOT WITHIN THESE SPECIFIED TOLERANCES AND PRE-INSTALLATION FLOOR PREPARATION WORK IS REQUIRED, THIS WORK CAN BE

PROVIDED BY iFORTRESS OR OTHERS AT AN ADDITIONAL COST - SHEET D.12 FOR WALL PANEL TO SLAB DETAIL

DUE TO THE INSTALLATION OF PERIMETER OR END COLUMNS, THE INSTALLATION OF THE INSIDE CHANNEL PLATES IS NOT CONTINUOUS. THEREFORE, INSIDE CHANNEL PLATES ARE TO BE CUT IN THE

FIELD TO LENGTHS THAT ARE EQUAL TO THE DISTANCES BETWEEN END COLUMN BASES.

WALL SECTION VIEW

N.T.S.

DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.

DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR

TRAINING DURING THE PERFORMANCE OF A GOVERNMENT CONTRACT, DETERMINED DECEMBER 5,

2017. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO USAF AFMC AFLCMC/WNS.

15'

72"

OPENING

74"

MINIMUM WALL OPENING

OPENING

72" UPPER PANEL

85"

MINIMUM WALL OPENING

19" DOOR HEADER PANEL

4" CEILING PANEL

15'

36"

OPENING

38"

MINIMUM WALL OPENING

OPENING

72" UPPER PANEL

85"

MINIMUM WALL OPENING

19" DOOR HEADER PANEL

4" CEILING PANEL

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

DOUBLE DOOR PANEL

ELEVATION

S.06

NOTES:

BUILDING FLOOR LEVEL SPECIFICATION - FROM THE CENTERLINE OF THE CHANNEL TROUGH, AN AREA OF THE BUILDING FLOOR EQUAL TO EIGHTEEN INCHES WIDE (18" WIDE), NINE INCHES (9") TO EITHER

SIDE OF THE CENTERLINE, AND AS LONG AS THE LENGTH OF ALL ASSEMBLED iGUARD ARMOR WALL PANELS™, NOT TO EXCEED

" OVER 8'. IF DETERMINED AT THE TIME OF THE SITE SURVEY THAT THE

DESIGNATED FLOOR AREA IS NOT WITHIN THESE SPECIFIED TOLERANCES AND PRE-INSTALLATION FLOOR PREPARATION WORK IS REQUIRED, THIS WORK CAN BE PROVIDED BY iFORTRESS OR OTHERS AT

AN ADDITIONAL COST - SHEET D.13 FOR WALL PANEL TO SLAB DETAIL

HEADER HEIGHT IS DEPENDENT UPON FINAL FOOTER HEIGHT DESIGNATED.

MINIMUM DOOR FOOTER HEIGHT IS 4".

DOOR PANEL FOOTER HEIGHT CAN BE INCREASED TO ACCOMPANY RAISED FLOOR SCENARIOS.

LEVEL HEIGHT OF INSTALLED RAISED FLOOR MUST BE A MINIMUM OF 1/4" BELOW THE BOTTOM OF THE DOOR TO ALLOW FOR FULL DOOR SWING.

FINAL DOOR PANEL FOOTER HEIGHT TO BE VERIFIED ON FINAL SIGNED DRAWINGS.

DOOR PANEL FLOOR CLEARANCE DETAIL DIMENSIONS WILL VARY BASED UPON FINAL FOOTER HEIGHT.

2) IF LEVEL OF THE EXISTING FLOOR WITHIN THE CHANNEL TROUGH IS NOT WITHIN iFORTRESS' LEVEL TOLERANCE (NOT TO EXCEED 1/4" VARIATION PER OVERALL ASSEMBLED WALL LENGTH), A SELF

LEVELER, SUCH AS QUICKCRETE CAN BE ADDED WITHIN THE 4" SPACE BETWEEN THE CHANNEL PLATES ONLY. THIS COULD EFFECT FINAL DOOR SILL HEIGHT.

EXTERIOR DOUBLE DOOR PANEL ELEVATION

N.T.S.

INTERIOR SINGLE DOOR PANEL ELEVATION

N.T.S.

EXTERIOR DOOR COMPONENT LIST:

(1) 1 pc. S. Parker Hardware SL8160 Series Heavy

Duty Cylindrical Leverset

(2) 3 pc. Five Knuckle Ball Bearing Hinges 4

" x 4

(3) 1 pc. S. Parker 900 Series Door Closer

(4) Silicon Smoke Seals

(5) 5" Widex

" High Saddle Threshold

(6) Vinyl Bottom Door Sweep

(7)

" x

" Astragal (Double Door Only)

(8) Manual Flush Bolt (Double Door Only)

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF DEFENSE AND

U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR

TRAINING DURING THE PERFORMANCE OF A GOVERNMENT CONTRACT, DETERMINED

DECEMBER 5, 2017. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO USAF

AFMC AFLCMC/WNS.

B

A

A

C

SECTION - C

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

S.07

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

iPassage STC 50

DOOR DETAILS

SECTION - A

SECTION - B

DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF

DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A

C_SEGT

C_TEGT

C_TEET

C_SGGTC_SGGS

C_TGGS

C_TGES C_TGET

C_TGGT

TYPICAL JOINT SHIELD CONFIGURATIONS

N.T.S.

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

CEILING PANEL DETAILS

D.01

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF

DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A

GROOVE

GROOVE

STARTER/ENDER

STARTER/ENDER

TONGUE/GROOVE

TONGUE/GROOVE

STARTER/ENDER

(FASCIA)

STARTER/ENDER

(FASCIA)

WITH PANEL NAMING CONVENTIONS

N.T.S.

PANEL NAMING CONVENTIONS

N.T.S.

DIMETRIC VIEW OF C_SGGS CEILING PANEL

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

CEILING PANEL DETAILS

D.02

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF

DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A

CAMPORT OPENING

" #11 THREAD COUNT

THROAT DEPTH = 1-

" [0.029 m]

(TYP)

1'-0

[0.316 m]

VARIES

[0.294 m]

2'

[0.610 m]

(TYP)

1'-10

[0.573 m]

2'

[0.610 m]

(TYP)

1'-0

[0.316 m]

2'

[0.610 m]

(TYP)

C_SEGT

C_TEGT

C_TEET

C_SGGT C_SGGS

C_TGGS

C_TGESC_TGET

C_TGGT

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

CEILING CAMPORT DETAILS

D.03

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF

DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A

[0.294 m]

2'

[0.610 m]

(TYP)

1'-0

[0.316 m]

[0.037 m]

1'-4

[0.417 m]

2'

[0.610 m]

(TYP)

VARIES

2'

[0.610 m]

(TYP)

[0.202 m]

[0.140 m]

[0.268 m]

[0.192 m]

CAMPORT OPENING

" #11 THREAD COUNT

THROAT DEPTH = 1-

" [0.029 m]

(TYP)

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

WALL CAMPORT DETAILS

D.04

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF

DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A

4"

[0.102 m]

12'

[3.658 m]

JOINT SHIELD

(TYP)

1'-11

[0.609 m]

1'-11

[0.609 m]

2'-0

[0.628 m]

4"

[0.102 m]

12'

[3.658 m]

EXTERIOR

SKIN

INTERIOR

SKIN

MALE CAMLOCK

FEMALE

CAMLOCK

INTERIOR WALL PANEL SURFACE

PREFINISHED WITH PROTECH #PS111W9

POWDER - HIGH REFLECTANCE WHITE

4"

[0.102 m]

ISOMETRIC VIEW OF PANEL

N.T.S.

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

WALL PANEL DETAIL

D.05

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF

DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A

12'

[3.658 m]

JOINT SHIELD

(TYP)

1'-11

[0.609 m]

1'-11

[0.609 m]

2'-0

[0.628 m]

4"

[0.102 m]

12'

[3.658 m]

PORTAL ASSEMBLY

ATTACHED TO PANEL SKIN

11'-0

[3.364 m]

1'

[0.304 m]

6" x 6" [0.152 m x 0.152 m] OPENING

INTERIOR

SKIN

MALE CAMLOCK

FEMALE

CAMLOCK

1'

[0.305 m]

NEMA 3R ENCLOSURES WIEGMANN MANUFACTURING OR EQUAL

SCREW COVER W/ 4 HOLES ON BACK

1'-4"

[0.406 m]

6"

[0.152 m]

EXTERIOR

SKIN

INTERIOR WALL PANEL SURFACE

PREFINISHED WITH PROTECH #PS111W9

POWDER - HIGH REFLECTANCE WHITE

4"

[0.102 m]

ISOMETRIC VIEW OF PANEL

N.T.S.

NOTES:

THE JUNCTION BOX WILL BE MOUNTED ON THE WALL PANEL BY AN AUTHORIZED INSTALLER ONLY WITH FOUR (4) SCREWS

AND A SEALANT THAT WILL BOND THE BOX TO THE PANEL.

FOLLOWING THE INSTALLATION OF THE JUNCTION BOXES, THE EXTERIOR SURFACES OF THE JUNCTION BOXES AND PANELS

ARE COATED WITH FIBERTECH F50 PENETRATING-PRIMER FOLLOWED BY FIBERTECH F51 SEALER-COAT.

JUNCTION BOX - EXTERIOR NEMA 3R

6” EXTERIOR PORTAL - RSC101006 - 10 X 10 X 6

9” EXTERIOR PORTAL - RSC121210 - 12 X 12 X 10

12” EXTERIOR PORTAL - RSC161610 - 16 X 16 X 10

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

6" HIGH PORTAL PANEL

DETAIL

D.06

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

DISTRIBUTION STATEMENT D. DISTRIBUTION

AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.

DoD CONTRACTORS ONLY, NECESSARY FOR

OPERATION, MAINTENANCE, INSTALLATION, OR

TRAINING DURING THE PERFORMANCE OF A

GOVERNMENT CONTRACT, DETERMINED DECEMBER

5, 2017. OTHER REQUESTS FOR THIS DOCUMENT

SHALL BE REFERRED TO USAF AFMC AFLCMC/WNS.

12'

[3.658 m]

JOINT SHIELD

(TYP)

1'-11

[0.609 m]

1'-11

[0.609 m]

2'-0

[0.628 m]

4"

[0.102 m]

12'

[3.658 m]

[0.294 m]

EXTERIOR

SKIN

INTERIOR

SKIN

MALE CAMLOCK

PORTAL ASSEMBLY

ATTACHED TO PANEL SKIN

6" x 6" [0.152 m x 0.152 m] OPENING

[0.218 m]

NEMA 3R ENCLOSURES WIEGMANN

MANUFACTURING OR EQUAL

SCREW COVER W/ 4 HOLES ON BACK

1'-4"

[0.406 m]

6"

[0.152 m]

INTERIOR WALL PANEL SURFACE

PREFINISHED WITH PROTECH #PS111W9

POWDER - HIGH REFLECTANCE WHITE

FEMALE

CAMLOCK

4"

[0.102 m]

ISOMETRIC VIEW OF PANEL

N.T.S.

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

6" LOW PORTAL PANEL

DETAIL

D.07

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

NOTES:

THE JUNCTION BOX WILL BE MOUNTED ON THE WALL PANEL BY AN AUTHORIZED INSTALLER ONLY WITH FOUR (4) SCREWS

AND A SEALANT THAT WILL BOND THE BOX TO THE PANEL.

FOLLOWING THE INSTALLATION OF THE JUNCTION BOXES, THE EXTERIOR SURFACES OF THE JUNCTION BOXES AND PANELS

ARE COATED WITH FIBERTECH F50 PENETRATING-PRIMER FOLLOWED BY FIBERTECH F51 SEALER-COAT.

JUNCTION BOX - EXTERIOR NEMA 3R

6” EXTERIOR PORTAL - RSC101006 - 10 X 10 X 6

9” EXTERIOR PORTAL - RSC121210 - 12 X 12 X 10

12” EXTERIOR PORTAL - RSC161610 - 16 X 16 X 10

DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF

DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

iPORTAL™ ASSEMBLY

D.08

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

DISTRIBUTION STATEMENT D. DISTRIBUTION

AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.

DoD CONTRACTORS ONLY, NECESSARY FOR

OPERATION, MAINTENANCE, INSTALLATION, OR

TRAINING DURING THE PERFORMANCE OF A

GOVERNMENT CONTRACT, DETERMINED DECEMBER

MALE CAMLOCKFEMALE CAMLOCK

2'

(TYP)

1'-7

2'

(TYP)

MALE CAMLOCK OF WALL PANEL

INTERLOCKS WITH FEMALE

CAMLOCK IN CEILING PANEL

12'-4"

EXTERIOR SURFACE OF WALL AND

CEILING PANELS ARE COATED WITH

FIBERTECH F50 PENETRATING-PRIMER

FOLLOWED BY FIBERTECH F51

SEALER-COAT FOLLOWING INSTALLATION

INTERIOR SURFACES OF WALL AND

CEILING PANELS ARE PREFINISHED WITH

PROTECH #PS111W9 POWDER - HIGH

REFLECTANCE WHITE. THE INTERIOR

SURFACES OF THE PANELS IN THE

SIMULATOR ROOM WILL BE COMPLETELY

COVERED WITH BLACK, iCOUSTIC PANELS.

NOTES:

PANEL CONNECTIONS ARE MADE BY MALE AND FEMALE

CAMLOCKS MANUFACTURED WITHIN THE PANEL ASSEMBLIES.

MALE CAMLOCKS INTERLOCK WITH THE FEMALE CAMLOCKS

BY MEANS OF THE CAMPORT OPENINGS LOCATED ON THE

INTERIOR OF THE ASSEMBLY.

SEE SHEETS D.03 & D.04 FOR TYPICAL CAMPORT LOCATIONS.

EXTERIOR VIEW OF WALL PANEL CONNECTION

N.T.S.

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

WALL PANEL CONNECTION

AND FINISH DETAIL

D.09

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

DISTRIBUTION STATEMENT D. DISTRIBUTION

AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.

DoD CONTRACTORS ONLY, NECESSARY FOR

OPERATION, MAINTENANCE, INSTALLATION, OR

TRAINING DURING THE PERFORMANCE OF A

GOVERNMENT CONTRACT, DETERMINED DECEMBER

TOP VIEW OF WALL PANEL

MALE CAMLOCK OF WALL PANEL

INTERLOCKS WITH FEMALE

CAMLOCK IN CEILING PANEL

AROUND PERIMETER

1'

2'

(TYP)

FEMALE CAMLOCKMALE CAMLOCK

EXTERIOR SURFACE OF WALL

AND CEILING PANELS ARE

COATED WITH FIBERTECH F50

PENETRATING-PRIMER

FOLLOWED BY FIBERTECH

F51 SEALER-COAT

FOLLOWING INSTALLATION

INTERIOR SURFACES OF WALL AND CEILING

PANELS ARE PREFINISHED WITH PROTECH

#PS111W9 POWDER - HIGH REFLECTANCE WHITE.

THE INTERIOR SURFACES OF THE PANELS IN THE

SIMULATOR ROOM WILL BE COMPLETELY

COVERED WITH BLACK, iCOUSTIC PANELS.

TOP VIEW OF CEILING PANEL CONNECTION

N.T.S.

NOTES:

PANEL CONNECTIONS ARE MADE BY MALE AND FEMALE

CAMLOCKS MANUFACTURED WITHIN THE PANEL ASSEMBLIES.

MALE CAMLOCKS INTERLOCK WITH THE FEMALE CAMLOCKS

BY MEANS OF THE CAMPORT OPENINGS LOCATED ON THE

INTERIOR OF THE ASSEMBLY.

SEE SHEETS D.03 & D.04 FOR TYPICAL CAMPORT LOCATIONS.

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

CEILING PANEL CONNECTION

AND FINISH DETAIL

D.10

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

DISTRIBUTION STATEMENT D. DISTRIBUTION

AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.

DoD CONTRACTORS ONLY, NECESSARY FOR

OPERATION, MAINTENANCE, INSTALLATION, OR

TRAINING DURING THE PERFORMANCE OF A

GOVERNMENT CONTRACT, DETERMINED DECEMBER

AA

CAMPORT OPENING

" #11 THREAD COUNT

THROAT DEPTH = 1-

(TYP)

U-STRUT CHANNEL

NOTES:

U-STRUT CHANNEL TO BE ATTACHED TO WALL AND CEILING

PANELS UTILIZING THE CAMPORT OPENINGS AND THE

NECESSARY CONNECTING HARDWARE WITH 5/8" #11 THREAD

COUNT.

SEE SHEETS D.03 & D.04 FOR TYPICAL CAMPORT LOCATIONS.

TOP VIEW OF CEILING PANEL CONNECTION

N.T.S.

U-STRUT MOUNTING DETAIL

N.T.S.

SECTION A-A

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

U-STRUT MOUNTING

DETAIL

D.11

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

SECURE TO PANELS AT CAMPORT OPENINGS USING

-14 x

-11 x 0.656 COARSE THREAD INSERTS AND x 11 x 1 COARSE THREAD SOCKET HEAD CAP

SCREWS TIGHTENED TO 1190 in-lbs TORQUE.

DISTRIBUTION STATEMENT D. DISTRIBUTION

AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.

DoD CONTRACTORS ONLY, NECESSARY FOR

OPERATION, MAINTENANCE, INSTALLATION, OR

TRAINING DURING THE PERFORMANCE OF A

GOVERNMENT CONTRACT, DETERMINED DECEMBER

INSIDE CHANNEL PLATE

"x2"x2"

OUTSIDE CHANNEL PLATE

"x2"x3"

4" STANDARD PANEL DEPTH

1" x

" CLOSED CELL GASKET

(COMPRESSES TO LESS THAN 1/16")

" TAPCON, EMBED 2

" MIN. (TYP.)

#12 HEX HEAD SHEET METAL SCREWS

(EACH SIDE)

" TAPCON, EMBED 2

" MIN.

NEW CONCRETE SLAB BY OTHERS

EXTERIOR SURFACES OF PANELS AND

CHANNEL PLATES ARE COATED WITH

FIBERTECH F50 PENETRATING-PRIMER

(FIELD APPLIED) FOLLOWED BY FIBERTECH

F51 SEALER-COAT (FIELD APPLIED).

4" STEEL TUBE COLUMN

" x 2

" CHANNEL RAIL

END COLUMN BASE PLATE

" SIMPSON TITEN HD SCREW ANCHOR,

EMBED 3" MIN.

1'

CAULK

" 20 GA. COUNTERFLASHING

HIGH BOND TAPE

6"8"

(1) #12 SCREW AT CENTER

(4) #12 SCREWS AT EACH END

INSIDE AND OUTSIDE CHANNEL PLATE

4"

" TAPCON SCREWS. EMBED 2

" MIN.

SCREW AND TAPCON PATTERN

(INSIDE AND OUTSIDE)

NOTES:

1) BUILDING FLOOR LEVEL SPECIFICATION FOR THE CHANNEL PLATE FOOTPRINT ONLY - FROM THE CENTERLINE OF THE CHANNEL TROUGH, AN AREA OF THE BUILDING FLOOR EQUAL TO EIGHTEEN

INCHES WIDE (18" WIDE), NINE INCHES (9") TO EITHER SIDE OF THE CENTERLINE, AND AS LONG AS THE LENGTH OF ALL ASSEMBLED iGUARD ARMOR WALL PANELS™, NOT TO EXCEED

" OVER 8'. IF

DETERMINED AT THE TIME OF THE SITE SURVEY THAT THE DESIGNATED FLOOR AREA IS NOT WITHIN THESE SPECIFIED TOLERANCES AND PRE-INSTALLATION FLOOR PREPARATION WORK IS REQUIRED, THIS WORK CAN BE PROVIDED BY iFORTRESS OR OTHERS AT AN ADDITIONAL COST

2) IF LEVEL OF THE EXISTING FLOOR WITHIN THE CHANNEL TROUGH IS NOT WITHIN iFORTRESS' LEVEL TOLERANCE (NOT TO EXCEED 1/4" VARIATION PER OVERALL ASSEMBLED WALL LENGTH), A SELF

LEVELER, SUCH AS QUICKCRETE CAN BE ADDED WITHIN THE 4" SPACE BETWEEN THE CHANNEL PLATES ONLY. THIS COULD EFFECT FINAL DOOR SILL HEIGHT.

3) TAPCON CONCRETE SCREWS ATTACH CHANNEL PLATES TO EXISTING FLOOR SLAB UTILIZING THE PRE-EXISTING HOLES MANUFACTURED IN THE CHANNEL PLATES.

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

WALL PANEL TO SLAB

DETAIL

D.12

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF

DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A

INSULATION ADHESIVE

" SLOPE CARLISLE SURE-SEAL

TAPERED HP-H POLYISOCYNURATE

CARLISLE SYNTEC LOW VOC

BONDING ADHESIVE

60 MIL EPDM ROOF

MEMBRANE

iGUARD ARMOR CEILING

PANEL

APPROVED FASTENER

WELD

GUTTER

" X 1

" ANGLE

WOOD NAILER

SEALANT

EPDM FLASHING MEMBRANE

46'

[14.021 m]

10'

[3.048 m]

10'

[3.048 m]

8'

[2.438 m]

10'

[3.048 m]

8'

[2.438 m]

TC

FRONT

BACK

LEFT SIDE

SC PC

26'

[7.928 m]

RIGHT SIDE

AC

C8TGGSC8TEGT C0TGGTC0TGGTC0TGGT

C8TGGSC8TEGT

C8TEGT

C8TEGT

C8TEGT

C8TEGT

C8TEGT

C8TEGT

C8TEET

C8SEGT

C8TGGS

C8TGGS

C8TGGS

C8TGGS

C8TGGS

C8TGGS

C8TGES

C8SGGS

C0TGGT

C0SGGT

C0TGGT

C0TGGT

C0TGGT

C0TGGT

C0TGGT

C0TGGT

C0TGET

C0TGGT

C0SGGT

C0TGGT

C0TGGT

C0TGGT

C0TGGT

C0TGGT

C0TGGT

C0TGET

C0TGGT

C0SGGT

C0TGGT

C0TGGT

C0TGGT

C0TGGT

C0TGGT

C0TGGT

C0TGET

C8TGGSC8TEGT C0TGGTC0TGGTC0TGGT

C8TGGSC8TEGT C0TGGTC0TGGTC0TGGT

C8TGGSC8TEGT C0TGGTC0TGGTC0TGGT

WELD OR SCREW 2' ON

CENTER TO JOINT SHIELDS

" HIGH NAILER WITH

FLASHING

PITCH

"/FOOT

2" WELD OR SCREW, 2' ON

CENTER

" HIGH

NAILER

WITH

FLASHING

" x 1

", 14 GAUGE ANGLE

ALONG ROOF PERIMETER

2 X 4 NAILER WITH GUTTER

PITCH

"/FOOT

2 X 4 NAILER WITH GUTTER

ROOF LEADER

(WHERE APPLICABLE)

26'

K STYLE, HIGH BACK

GUTTER SYSTEM

(SEE DETAIL)

ROOFING SYSTEM INSTALLED ON

TOP OF iFORTRESS MODULAR MCF

(SEE DETAIL)

INSULATION TAPERED AT 1/4" PER FOOT

60 MIL EPDM ROOF MEMBRANE

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

ROOF DETAIL FOR

EXTERIOR INSTALLATIONS

D.13

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

ROOF SECTION

N.T.S.

NOTES AND INSTALLATION INSTRUCTIONS:

A SINGLE LAYER OF STANDARD SINGLE PLY ETHYLENE PROPLYLENE DIENE MONOMER (EPDM) MEMBRANE IS LAID OVER THE EXTERIOR SIDE OF ALL CEILING PANELS. LAY THE MEMBRANE IN SITU ONTO

THE DECK FOR MEASUREMENT, WITH ENOUGH MATERIAL EXTENDING BEYOND THE PERIMETERS TO TRIM UP LATER. ROLL HALF THE MEMBRANE BACK TOWARDS THE MIDDLE OF THE ROOF. USING A 9”

EMULSION ROLLER, SQUEEGEE OR SOFT BROOM, APPLY THE WATER-BASED BONDING ADHESIVE (DECK ADHESIVE) ONTO THE SUBSTRATE SURFACE ONLY. IT IS NOT A CONTACT ADHESIVE AND

THEREFORE NONE IS REQUIRED FOR THE EPDM SURFACE ITSELF. THE ADHESIVE SHOULD NOT BE ALLOWED TO FREEZE AND MUST NOT BE APPLIED IF FREEZING TEMPERATURES ARE FORECAST WITHIN

THE FOLLOWING 24 HOUR PERIOD AFTER BONDING.

ONCE APPLIED, THE MEMBRANE CAN BE LAID INTO THE ADHESIVE WHILST STILL WET. ROLL THE MEMBRANE INTO THE ADHESIVE AVOIDING STRESS OR WRINKLES, TAKING CARE TO SPOT ANY DEBRIS THAT

MAY HAVE FALLEN ONTO THE DECK IN THE MEANTIME. ENTRAPPED AIR AND WRINKLES CAN BE REMOVED BY GENTLY SMOOTHING WITH A SOFT BRISTLE BROOM, ADDING MORE PRESSURE WITH EACH

PASS OF THE BROOM. DO NOT STRETCH THE SHEET.

ROLL BACK THE OTHER HALF OF THE MEMBRANE UP TO THE ALREADY APPLIED ADHESIVE AND REPEAT THE PROCEDURE. IT IS IMPORTANT THAT A 6” WIDE STRIP ALONG ALL PERIMETER EDGES ARE

GLUED USING THE YELLOW SOLVENT BASED CONTACT ADHESIVE, THUS ENSURING THE MEMBRANE IS IMMEDIATELY SECURED IN THE EVENT OF STRONG WINDS CAUSING UPLIFT BEFORE THE WATER

BASED DECKING ADHESIVE HAS COMPLETELY BONDED.

ANGLE INSTALLATION PLAN

N.T.S.

NOTE: FOLLOW THE

PROCEDURES FOR WELDING

SHEET METAL (16 GAUGE)

ROOF GUTTER DETAIL

N.T.S.

DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF DEFENSE

AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A GOVERNMENT CONTRACT, DETERMINED DECEMBER 5, 2017. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE

REFERRED TO USAF AFMC AFLCMC/WNS.

4" STANDARD PANEL DEPTH

INSIDE CHANNEL PLATES

(CHISTD) ON BOTH SIDES

CEILING PANEL

CONCRETE SLAB

" x 2

" CHANNEL RAIL

INSIDE CHANNEL PLATES (CHISTD)

ON BOTH SIDES.

#12 HEX HEAD SHEET METAL

SCREWS (EACH SIDE)

" TAPCON SCREWS EMBED

" MIN. (EACH SIDE)

#12 HEX HEAD SHEET METAL

SCREWS (EACH SIDE)

4" STANDARD PANEL DEPTH

INSIDE CHANNEL PLATES

(CHISTD) ON BOTH SIDES

EXTERIOR WALL PANEL

#12 HEX HEAD SHEET METAL SCREWS

(EACH SIDE)

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

INTERIOR WALL DETAIL

D.14

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

SIDE VIEW OF FLOATING WALL PANEL CONNECTIONS

N.T.S.

NOTES:

1) BUILDING FLOOR LEVEL SPECIFICATION FOR CHANNEL PLATE FOOTPRINT ONLY - FROM THE CENTERLINE OF THE CHANNEL TROUGH, AN AREA OF THE BUILDING FLOOR EQUAL TO EIGHTEEN INCHES

WIDE (18" WIDE), NINE INCHES (9") TO EITHER SIDE OF THE CENTERLINE, AND AS LONG AS THE LENGTH OF ALL ASSEMBLED iGUARD ARMOR WALL PANELS™, NOT TO EXCEED

" OVER 8'. IF DETERMINED AT

THE TIME OF THE SITE SURVEY THAT THE DESIGNATED FLOOR AREA IS NOT WITHIN THESE SPECIFIED TOLERANCES AND PRE-INSTALLATION FLOOR PREPARATION WORK IS REQUIRED, THIS WORK CAN BE

PROVIDED BY iFORTRESS OR OTHERS AT AN ADDITIONAL COST

2) IF LEVEL OF THE EXISTING FLOOR WITHIN THE CHANNEL TROUGH IS NOT WITHIN iFORTRESS' LEVEL TOLERANCE (NOT TO EXCEED 1/4" VARIATION PER OVERALL ASSEMBLED WALL LENGTH), A SELF

LEVELER, SUCH AS QUICKCRETE CAN BE ADDED WITHIN THE 4" SPACE BETWEEN THE CHANNEL PLATES ONLY. THIS COULD EFFECT FINAL DOOR SILL HEIGHT.

3) TAPCON CONCRETE SCREWS ATTACH CHANNEL PLATES TO EXISTING FLOOR SLAB UTILIZING THE PRE-EXISTING HOLES MANUFACTURED IN THE CHANNEL PLATES.

TOP VIEW OF FLOATING WALL PANEL CONNECTIONS

N.T.S.

DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF

DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

E37

REVISION NOTESREV DATE RP CO

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

ENCLOSURE BONDING AND

GROUNDING DETAIL

D.15

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

DISTRIBUTION STATEMENT D. DISTRIBUTION

AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.

DoD CONTRACTORS ONLY, NECESSARY FOR

OPERATION, MAINTENANCE, INSTALLATION, OR

TRAINING DURING THE PERFORMANCE OF A

GOVERNMENT CONTRACT, DETERMINED DECEMBER

N.T.S.

SECTION A

iGUARD ARMOR PANEL INTERIOR ELEVATIONS

8'-8"

[2.642 m]

6'

[1.829 m]

W

R

O C

S

CBM086B-B

W

R

O C

W

L

O C

S W

L O

C

W

S

T D

S W

S T

D

W

S

T D

S W

S T

D

W

S

T D

S W

S T

D

W

S

T D

S W

S T

D

W

S

T D

S W

S T

D

W

M

H x x x S

W

S

T D

W

S

T D

S W

S T

D

W

S

T D

S W

S T

D

W

S

T D

S W

S T

D

W

H P

S W

S T

D

W

S

T D

S W

S T

D

W

M

H x x x S

W

S

T D

W

S

T D

S W

S T

D

W

S

T D

S W

S T

D

W

L P

S W

S T

D

W

S

T D

S W

S T

D

W

S

T D

S W

S T

D

W

S

T D

S W

S T

D

W

S

T D

S W

S T

D

W

S

T D

S W

S T

D

W

S

T D

S W

S T

D

W

S

T D

S W

S T

D

CBM116-B CBM116-B CBM116-W CBM086A-W

26"

[0.660 m] iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

RP CO

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

iGUARD ARMOR WALL PANELS™

ELEVATION VIEW

SECTION A

I.01

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

REVISION NOTESREV DATE RP CO

E

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

DISTRIBUTION STATEMENT D. DISTRIBUTION

AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.

DoD CONTRACTORS ONLY, NECESSARY FOR

OPERATION, MAINTENANCE, INSTALLATION, OR

TRAINING DURING THE PERFORMANCE OF A

GOVERNMENT CONTRACT, DETERMINED DECEMBER

SECTION B

iGUARD ARMOR PANEL INTERIOR ELEVATIONS

SOUTH

8'-8"

[2.642 m]

6'

[1.829 m]

62 63 64 65 66 67 69 70 71 72 73 7468 75

6149 50 51 52 53 54 55 56 57

W

R

O C

S

W

S

T D

S

W

S

T D

S

W

S

T D

S

W

S

T D

S

W

S

T D

S

W

S

T D

S

W

S

T D

S

W

S

T D

S

W

S

T D

S

W

S

T D

S

W

S

T D

S

W

S

T D

S

W

L

O C

S W

L O

C

W

R

O C

W

S

T D

W

S

T D

W

S

T D

W

S

T D

W

S

T D

W

S

T D

W

S

T D

W

S

T D

D L

D M

F E

DH961900DMF-E

D R

D M

F E

CMB146A-W CBM146B-W

CMB146A-W CBM146B-W

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

RP CO

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

iGUARD ARMOR WALL PANELS™

ELEVATION VIEW

SECTION B

I.02

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

REVISION NOTESREV DATE RP CO

E

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

DISTRIBUTION STATEMENT D. DISTRIBUTION

AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.

DoD CONTRACTORS ONLY, NECESSARY FOR

OPERATION, MAINTENANCE, INSTALLATION, OR

TRAINING DURING THE PERFORMANCE OF A

GOVERNMENT CONTRACT, DETERMINED DECEMBER

SECTION C

iGUARD ARMOR PANEL INTERIOR ELEVATIONS

8'-8"

[2.642 m]

6'

[1.829 m]

101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122

77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98

W R

O C

S W

R

O C

W L O

C S

W L O

C

W S

T D

S

W S

T D

S

W H

P S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

CBM086B-W CBM116-W CBM116-B CBM116-B CBM086A-B

W S

T D

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

RP CO

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

iGUARD ARMOR WALL PANELS™

ELEVATION VIEW

SECTION C

I.03

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

REVISION NOTESREV DATE RP CO

E

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

DISTRIBUTION STATEMENT D. DISTRIBUTION

AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.

DoD CONTRACTORS ONLY, NECESSARY FOR

OPERATION, MAINTENANCE, INSTALLATION, OR

TRAINING DURING THE PERFORMANCE OF A

GOVERNMENT CONTRACT, DETERMINED DECEMBER

SECTION D

iGUARD ARMOR PANEL INTERIOR ELEVATIONS

8'-8"

[2.642 m]

6'

[1.829 m]

139 140 141 142 143 144 145 146 147 148 149 150

125 126 127 128 129 130 131 132 133 134 135 136

W R

O C

S W

R

O C

W L O

C S

W L O

C

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

W S

T D

S

CBM146A-B CBM146B-B

CBM146A-B CBM146B-B

iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

RP CO

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

iGUARD ARMOR WALL PANELS™

ELEVATION VIEW

SECTION D

I.04

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

REVISION NOTESREV DATE RP CO

E

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

DISTRIBUTION STATEMENT D. DISTRIBUTION

AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.

DoD CONTRACTORS ONLY, NECESSARY FOR

OPERATION, MAINTENANCE, INSTALLATION, OR

TRAINING DURING THE PERFORMANCE OF A

GOVERNMENT CONTRACT, DETERMINED DECEMBER

SECTION E

iGUARD ARMOR PANEL INTERIOR ELEVATIONS

8'-8"

[2.642 m]

6'

[1.829 m]

166 167 168 169

153 154 155 156 160

170 171 173 174 175 176 177

163161

157 159

W F

E L S

C

O W

F

E L C

O

W F

E R

S C

O W

F

E R

C

O

W H

P S

F

L T

W H

P S

F

L T

W H

P S

F

L T

W M

H x x x S

F

L T

W S

T D

F

L T

W S

T D

F

L T

W S

T D

F

L T

W S

T D

F

L T

W S

T D

F

L T

W H

P S

F

L T

W S

T D

S F

L T

W S

T D

S F

L T

W S

T D

S F

L T

W S

T D

S F

L T

W S

T D

S F

L T

W S

T D

S F

L T

W S

T D

S F

L T

D R

S

T C

D L S

T C

D L M

F

D R

M

F

CBM304

DH721900MF

DH961900STC

26"

[0.660 m] iFORTRESS

SHIP TO:

L A

N

J O

B

N

O

GENERATED IN AUTOCAD

DO NOT SCALE DRAWING

IMPORTANT NOTE: ALL INFORMATION

CONTAINED HEREIN IS CONFIDENTIAL

WOODLAND PARK, NEW JERSEY

2 3 4 5 6

A

2 3 4 5 6

B

C

D

A

B

C

D

END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE

RP CO

DATE

SCALE SHEET SIZE DRAWING NO. REV.

NONE BOF

iGUARD ARMOR WALL PANELS™

ELEVATION VIEW

SECTION E

I.05

SPECIFICATION REQUIRED WITH SIGNED DRAWINGS

PLEASE SEE SHEET S.01

INTEGRATOR

USAF JTC RSS

Model i-TCO-01196-14EXT

9/15/17

REVISION NOTESREV DATE RP CO

E

RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP

REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP

REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN

REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN

LAN

LAN

REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN

DISTRIBUTION STATEMENT D. DISTRIBUTION

AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.

DoD CONTRACTORS ONLY, NECESSARY FOR

OPERATION, MAINTENANCE, INSTALLATION, OR

TRAINING DURING THE PERFORMANCE OF A

GOVERNMENT CONTRACT, DETERMINED DECEMBER

SECTION F

iGUARD ARMOR PANEL INTERIOR ELEVATIONS

8'-8"

[2.642 m]

6'

[1.829 m]

184179

185 186 187 188 189

W F

E R

S C

O W

F

E R

C

O

W F

E L

W F

E L S

W S

T D

S F

L T

W H

P S

F

L T

W H

P S

F

L T

W S

T D

S F

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.