2.0_Structure_(373765-S.01)__20171213.pdf
PDF 4 MB Posted
- Attached to
- SOF Construct Pad Federal contract opportunity
- Solicitation number
- FA4855-18-R-0013
About this file
Structure
View the file
Other files for this federal contract opportunity
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
10'
[3.048 m]
10'
[3.048 m]
10'
[3.048 m]
8'
[2.438 m]
46'
[14.021 m]
26'
[7.925 m]
BACK
FRONT
RIGHT SIDE
LEFT SIDE
8'
[2.438 m]
MC6x15.1 CHANNEL
AROUND
PERIMETER OF
ROOM AND AT TOP
OF END WALLS
VESTIBULE
CONFERENCE
ROOM
SIMULATOR ROOM
iVENT
10"X10"
6" UPPER PORTAL
iVENT
8"X8"
9" LOWER PORTAL
6" UPPER PORTAL
12" UPPER PORTAL
6" UPPER PORTAL
iVENT
16"X8"
9" UPPER PORTAL
6" UPPER PORTAL
6" UPPER PORTAL
6" UPPER PORTAL
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
CUSTOMER TO CHECK
EXTERIOR COLOR OF MCF SERIES iFORTRESS™:BLACK COC. GROVE
(SELECT ONE)
_______BLACK _______COCONUT GROVE _______OTHER
(STANDARD) (STANDARD) (SPECIAL)
NOTE: THE EXTERIOR AND INTERIOR SURFACES OF THE iPASSAGE DOOR
SYSTEM™, AS WELL AS THE INTERIOR OF ALL PANELS, ARE FINISHED IN WHITE
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
WALL PANEL LAYOUT
S.01
NOTES:
BUILDING FLOOR LEVEL SPECIFICATION FOR THE CHANNEL PLATE FOOT PRINT ONLY - FROM THE CENTERLINE OF THE
CHANNEL TROUGH, AN AREA OF THE BUILDING FLOOR EQUAL TO EIGHTEEN INCHES WIDE (18" WIDE), NINE INCHES (9")
TO EITHER SIDE OF THE CENTERLINE, AND AS LONG AS THE LENGTH OF ALL ASSEMBLED iGUARD ARMOR WALL
PANELS™, NOT TO EXCEED
" OVER 8'. IF DETERMINED AT THE TIME OF THE SITE SURVEY THAT THE DESIGNATED
FLOOR AREA IS NOT WITHIN THESE SPECIFIED TOLERANCES AND PRE-INSTALLATION FLOOR PREPARATION WORK IS
REQUIRED, THIS WORK CAN BE PROVIDED BY iFORTRESS OR OTHERS AT AN ADDITIONAL COST - SHEET D.12 FOR WALL
PANEL TO SLAB DETAIL
*PORTAL PANEL LOCATION AND PORTAL DESIGNATIONS (HIGH OR LOW) MUST BE NOTED ON FINAL SIGNED DRAWINGS.
PLAN NORTH, SOUTH, EAST IS FOR INSTALLATION PURPOSES ONLY AND DOES NOT INDICATE TRUE CARDINAL
DIRECTIONS.
SEE SHEET S.06 FOR DOOR PANEL DETAIL, SHEET D.04 FOR CAMPORT DETAIL, SHEET D.05 FOR WALL PANEL DETAIL, SHEETS D.06, D.07 & D.08 FOR PORTAL PANEL DETAIL, SHEET D.09 FOR WALL PANEL CONNECTION AND FINISH DETAIL, D.11 FOR U-STRUT MOUNTING DETAIL AND SHEET D.13 FOR WALL PANEL TO SLAB DETAIL
DUE TO THE INSTALLATION OF PERIMETER OR END COLUMNS, THE INSTALLATION OF THE INSIDE CHANNEL PLATES IS
NOT CONTINUOUS. THEREFORE, INSIDE CHANNEL PLATES ARE TO BE CUT IN THE FIELD TO LENGTHS THAT ARE EQUAL
TO THE DISTANCES BETWEEN END COLUMN BASES.
INSTALLATION ABBREVIATIONS:
PD - PRIMARY DOOR
SD - SECONDARY DOOR
PC - PRIMARY CORNER
SC - SECONDARY CORNER
TC - TERTIARY CORNER
AC - ANCILLARY CORNER
QUANTITYHEIGHT
TOTAL QUANTITY OF WALL PANELS = 190
PANEL TYPE SYMBOL
DL118500DMF-E
DR118500DMF-E
DH961900DMF-E
DH721900MF
DL178500MF 1
DR178500MF
DL118600STC
DR118600STC
DH961900STC
PART NUMBER SYSTEM
(PNS)
COLORS
ALL COLUMNS, JOISTS AND CROSS BRACING ARE BLACK IN SIMULATOR ROOM AND
CONFERENCE ROOM.
ALL COLUMNS, JOISTS AND CROSS BRACING ARE WHITE IN VESTIBULE
SIMULATOR ROOM TO RECEIVE BLACK iCOUSTIC PANELS ON WALLS AND CEILING.
CONFERENCE ROOM TO RECEIVE iCOUSTIC PANELS ON WALLS AND CEILING - COLOR TO
BE SILVER NEUTRAL.
VESTIBULE - iFORTRESS PANELS FINISHED IN HIGH REFLECTANCE WHITE (NO iCOUSTIC
PANELS)
W88STD 64
W06STDS 63
W066HPS 2
W069LPS 1
W88ROC 4
W88FER-CO 2
W88FEL-CO 1
W88LOC 4
W06FERS-CO 2
W06FELS-CO 1
W06ROCS 4
W06LOCS 4
W06M1010HxxxS 1
W06M1010HxxxS 1
W88STD-FLT 9
W06STDS-FLT 9
W88FEL-15 1
W06FELS-15 1
W066HPS-FLT 4
W069HPS-FLT 1
W063HPS-FLT 1
W06M1608HxxxS-FLT 1
DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF
DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A
GOVERNMENT CONTRACT, DETERMINED DECEMBER 5, 2017. OTHER REQUESTS
FOR THIS DOCUMENT SHALL BE REFERRED TO USAF AFMC AFLCMC/WNS.
46'
[14.021 m]
10'
[3.048 m]
10'
[3.048 m]
8'
[2.438 m]
10'
[3.048 m]
8'
[2.438 m]
TC
FRONT
BACK
LEFT SIDE
SC PC
26'
[7.928 m]
RIGHT SIDE
AC
C8TGGS C8TEGTC0TGGT C0TGGT C0TGGT
C8TGGS C8TEGT
C8TEGT
C8TEGT
C8TEGT
C8TEGT
C8TEGT
C8TEGT
C8TEET
C8SEGT
C8TGGS
C8TGGS
C8TGGS
C8TGGS
C8TGGS
C8TGGS
C8TGES
C8SGGS
C0TGGT
C0SGGT
C0TGGT
C0TGGT
C0TGGT
C0TGGT
C0TGGT
C0TGGT
C0TGET
C0TGGT
C0SGGT
C0TGGT
C0TGGT
C0TGGT
C0TGGT
C0TGGT
C0TGGT
C0TGET
C0TGGT
C0SGGT
C0TGGT
C0TGGT
C0TGGT
C0TGGT
C0TGGT
C0TGGT
C0TGET
C8TGGS C8TEGTC0TGGT C0TGGT C0TGGT
C8TGGS C8TEGTC0TGGT C0TGGT C0TGGT
C8TGGS C8TEGTC0TGGT C0TGGT C0TGGT
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
CEILING PANEL LAYOUT
S.02
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
INSTALLATION ABBREVIATIONS:
PD - PRIMARY DOOR
SD - SECONDARY DOOR
PC - PRIMARY CORNER
SC - SECONDARY CORNER
TC - TERTIARY CORNER
AC - ANCILLARY CORNER
NOTES:
SEE SHEET D.03 FOR CAMPORT DETAIL, SHEET D.09 FOR WALL PANEL CONNECTION AND FINISH DETAIL, SHEET D.10 FOR CEILING PANEL
CONNECTION AND FINISH DETAIL, D.11 FOR U-STRUT MOUNTING DETAIL AND SHEET D.13 FOR ROOF DETAIL.
CEILING PANEL LEGEND
T: TONGUE
G: GROOVE
E: ENDER
S: STARTER
X: SPECIAL
PART NUMBER SYSTEM (PNS) QUANTITYLENGTH
TOTAL QUANTITY OF CEILING PANELS = 65
CEILING PANELS
3C0SGGT 10' [3.048 m]
33C0TGGT
11C8TEGT
3C0TGET
1C8TEET
1C8SEGT 8' [2.438 m]
10' [3.048 m]
10' [3.048 m]
C8TGES 1
C8TGGS 11
C8SGGS 18' [2.438 m]
8' [2.438 m]
8' [2.438 m]
8' [2.438 m]
8' [2.438 m]
DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF
DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A
26'
[7.823 m]
BACK
FRONT
LEFT SIDE
OUTLINE OF WALL PANELS
RIGHT SIDE
NOTES:
BUILDING FLOOR LEVEL SPECIFICATION - FROM THE CENTERLINE OF THE CHANNEL TROUGH, AN AREA OF THE BUILDING
FLOOR EQUAL TO EIGHTEEN INCHES WIDE (18" WIDE), NINE INCHES (9") TO EITHER SIDE OF THE CENTERLINE, AND AS LONG
AS THE LENGTH OF ALL ASSEMBLED iGUARD ARMOR WALL PANELS™, NOT TO EXCEED
" OVER 8'. IF DETERMINED AT THE
TIME OF THE SITE SURVEY THAT THE DESIGNATED FLOOR AREA IS NOT WITHIN THESE SPECIFIED TOLERANCES AND
PRE-INSTALLATION FLOOR PREPARATION WORK IS REQUIRED, THIS WORK CAN BE PROVIDED BY iFORTRESS OR OTHERS AT
AN ADDITIONAL COST - SHEET D.12 FOR WALL PANEL TO SLAB DETAIL
DUE TO THE INSTALLATION OF PERIMETER OR END COLUMNS, THE INSTALLATION OF THE INSIDE CHANNEL PLATES IS NOT
CONTINUOUS. THEREFORE, INSIDE CHANNEL PLATES ARE TO BE CUT IN THE FIELD TO LENGTHS THAT ARE EQUAL TO THE
DISTANCES BETWEEN END COLUMN BASES.
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
CHANNEL PLATE LAYOUT
S.03
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
INSTALLATION ABBREVIATIONS:
PD - PRIMARY DOOR
SD - SECONDARY DOOR
PC - PRIMARY CORNER
SC - SECONDARY CORNER
TC - TERTIARY CORNER
AC - ANCILLARY CORNER
PART NUMBER SYSTEM (PNS) QUANTITY
TOTAL LINEAR FEET = 649.33 FT [197.916 m]
CHANNEL PLATES
CHOSTD
CHOOCR-SPL2 4
LENGTH
28 in [0.711 m]
TYPE
INSIDE
OUTSIDE
TOTAL QUANTITY = 68
CHISTD-SPL2
4120 in [3.048 m] INSIDE
CHOSTD-SPL2 16120 in [3.048 m] OUTSIDE
CHISTD 28120 in [3.048 m] INSIDE
120 in [3.048 m]
DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF
DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A
26'
[7.925 m]
BACK
FRONT
LEFT SIDE
OUTLINE OF WALL PANELS
RIGHT SIDE
MC6x15.1 CHANNEL
AROUND
PERIMETER OF
ROOM AND AT TOP
OF END WALLS
10.0"
8.0"
1.5"
6.5"
1.5"
TYP
1/2" BASE PLATE OF END COLUMN
N.T.S.
4.0"
4.0"
6.0"
6.0"
1.0"
TYP
BASE PLATE OF CORNER COLUMN
N.T.S.
4.0"
4.0"
6.0"
16.0"
3.0"
1.0"
TYP
4.5"
TYP
5/8" CAP PLATE OF END COLUMN
N.T.S.
5/8" CAP PLATE OF MIDDLE COLUMN
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
COLUMN AND JOIST LAYOUT
S.04
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
NOTES:
BUILDING FLOOR LEVEL SPECIFICATION FOR CHANNEL PLATE FOOTPRINT ONLY - FROM THE CENTERLINE OF THE CHANNEL TROUGH, AN AREA OF THE
BUILDING FLOOR EQUAL TO EIGHTEEN INCHES WIDE (18" WIDE), NINE INCHES (9") TO EITHER SIDE OF THE CENTERLINE, AND AS LONG AS THE LENGTH
OF ALL ASSEMBLED iGUARD ARMOR WALL PANELS™, NOT TO EXCEED
" OVER 8'. IF DETERMINED AT THE TIME OF THE SITE SURVEY THAT THE
DESIGNATED FLOOR AREA IS NOT WITHIN THESE SPECIFIED TOLERANCES AND PRE-INSTALLATION FLOOR PREPARATION WORK IS REQUIRED, THIS
WORK CAN BE PROVIDED BY iFORTRESS OR OTHERS AT AN ADDITIONAL COST - SHEET D.12 FOR WALL PANEL TO SLAB DETAIL
DUE TO THE INSTALLATION OF PERIMETER OR END COLUMNS, THE INSTALLATION OF THE INSIDE CHANNEL PLATES IS NOT CONTINUOUS. THEREFORE, INSIDE CHANNEL PLATES ARE TO BE CUT IN THE FIELD TO LENGTHS THAT ARE EQUAL TO THE DISTANCES BETWEEN END COLUMN BASES.
INSTALLATION ABBREVIATIONS:
PD - PRIMARY DOOR
SD - SECONDARY DOOR
PC - PRIMARY CORNER
SC - SECONDARY CORNER
TC - TERTIARY CORNER
AC - ANCILLARY CORNER
PART NUMBER SYSTEM (PNS) QUANTITYLENGTH
TOTAL QUANTITY OF COLUMNS = 16
COLUMNS AND JOISTS
CLE173-B 14'-5" [4.450 m] 6
6J14304 25'-3 1/2" [7.708 m]
TYPE
14" JOIST - FINISH: BLACK
TOTAL QUANTITY OF JOISTS = 10
LEGEND
END COLUMN
CORNER COLUMN
JOIST
CHANNEL BRACE - FINISH: BLACK
CHANNEL BRACE - FINISH: WHITE
14" JOIST - FINISH: BLACK
14" JOIST - FINISH: BLACK
J14120
J14180
9'-11 1/2" [3.048 m]
14'-11 1/2" [4.572 m]
CLEW176-B 14'-8" [4.470 m] 1
CLE173-W 414'-5" [4.450 m]
CLC176-W 2
CLC176-B 2
CLEW176-W 114'-8" [4.470 m]
14'-8" [4.470 m]
14'-8" [4.470 m]
CBM116-B
CBM116-W
49'-8" [2.946 m]
29'-8" [2.946 m]
CHANNEL BRACE - FINISH: BLACKCBM086A-B
CBM086B-B
CHANNEL BRACE - FINISH: WHITE
CHANNEL BRACE - FINISH: BLACKCBM146A-B 212'-2" [3.708 m]
CHANNEL BRACE - FINISH: WHITE
CHANNEL BRACE - FINISH: BLACK
CBM086A-W
CBM086B-W
7'-2" [2.184 m]
7'-2" [2.184 m]
7'-2" [2.184 m]
7'-2" [2.184 m]
CHANNEL BRACE - FINISH: BLACKCBM146B-B 12'-2" [3.708 m]
CHANNEL BRACE - FINISH: WHITECBM146A-W 212'-2" [3.708 m]
2CHANNEL BRACE - FINISH: WHITECBM146B-W 12'-2" [3.708 m]
1CHANNEL BRACE - FINISH: WHITECBM304 25-4" [7.722 m]
1CHANNEL BRACE - FINISH: WHITECBM026 2'-2" [0.660 m]
1CHANNEL BRACE - FINISH: WHITECBM090 7'-6" [2.286 m]
DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF
DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A
FINISHED COLUMN
4" X 4"
14" J14304
DOUBLE JOIST
CEILING PANELS
4"
15'
OUTSIDE
CHANNEL PLATE
14'-8"
COLUMN BASE PLATE
FLOOR SLAB SPEC
F90
14"
INSIDE CHANNEL PLATE
13'-6"
8'-8"
6'
MC6x15.1 CHANNEL
12"
8" iCOUSTIC PANEL
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
ASSEMBLY INSIDE AND
OUTSIDE DIMENSIONS
S.05
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
NOTES:
BUILDING FLOOR LEVEL SPECIFICATION FOR THE CHANNEL PLATE FOOTPRINT ONLY - FROM THE CENTERLINE OF THE CHANNEL TROUGH, AN AREA OF THE BUILDING FLOOR EQUAL TO EIGHTEEN INCHES
WIDE (18" WIDE), NINE INCHES (9") TO EITHER SIDE OF THE CENTERLINE, AND AS LONG AS THE LENGTH OF ALL ASSEMBLED iGUARD ARMOR WALL PANELS™, NOT TO EXCEED
" OVER 8'. IF DETERMINED AT
THE TIME OF THE SITE SURVEY THAT THE DESIGNATED FLOOR AREA IS NOT WITHIN THESE SPECIFIED TOLERANCES AND PRE-INSTALLATION FLOOR PREPARATION WORK IS REQUIRED, THIS WORK CAN BE
PROVIDED BY iFORTRESS OR OTHERS AT AN ADDITIONAL COST - SHEET D.12 FOR WALL PANEL TO SLAB DETAIL
DUE TO THE INSTALLATION OF PERIMETER OR END COLUMNS, THE INSTALLATION OF THE INSIDE CHANNEL PLATES IS NOT CONTINUOUS. THEREFORE, INSIDE CHANNEL PLATES ARE TO BE CUT IN THE
FIELD TO LENGTHS THAT ARE EQUAL TO THE DISTANCES BETWEEN END COLUMN BASES.
WALL SECTION VIEW
N.T.S.
DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.
DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR
TRAINING DURING THE PERFORMANCE OF A GOVERNMENT CONTRACT, DETERMINED DECEMBER 5,
2017. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO USAF AFMC AFLCMC/WNS.
15'
72"
OPENING
74"
MINIMUM WALL OPENING
OPENING
72" UPPER PANEL
85"
MINIMUM WALL OPENING
19" DOOR HEADER PANEL
4" CEILING PANEL
15'
36"
OPENING
38"
MINIMUM WALL OPENING
OPENING
72" UPPER PANEL
85"
MINIMUM WALL OPENING
19" DOOR HEADER PANEL
4" CEILING PANEL
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
DOUBLE DOOR PANEL
ELEVATION
S.06
NOTES:
BUILDING FLOOR LEVEL SPECIFICATION - FROM THE CENTERLINE OF THE CHANNEL TROUGH, AN AREA OF THE BUILDING FLOOR EQUAL TO EIGHTEEN INCHES WIDE (18" WIDE), NINE INCHES (9") TO EITHER
SIDE OF THE CENTERLINE, AND AS LONG AS THE LENGTH OF ALL ASSEMBLED iGUARD ARMOR WALL PANELS™, NOT TO EXCEED
" OVER 8'. IF DETERMINED AT THE TIME OF THE SITE SURVEY THAT THE
DESIGNATED FLOOR AREA IS NOT WITHIN THESE SPECIFIED TOLERANCES AND PRE-INSTALLATION FLOOR PREPARATION WORK IS REQUIRED, THIS WORK CAN BE PROVIDED BY iFORTRESS OR OTHERS AT
AN ADDITIONAL COST - SHEET D.13 FOR WALL PANEL TO SLAB DETAIL
HEADER HEIGHT IS DEPENDENT UPON FINAL FOOTER HEIGHT DESIGNATED.
MINIMUM DOOR FOOTER HEIGHT IS 4".
DOOR PANEL FOOTER HEIGHT CAN BE INCREASED TO ACCOMPANY RAISED FLOOR SCENARIOS.
LEVEL HEIGHT OF INSTALLED RAISED FLOOR MUST BE A MINIMUM OF 1/4" BELOW THE BOTTOM OF THE DOOR TO ALLOW FOR FULL DOOR SWING.
FINAL DOOR PANEL FOOTER HEIGHT TO BE VERIFIED ON FINAL SIGNED DRAWINGS.
DOOR PANEL FLOOR CLEARANCE DETAIL DIMENSIONS WILL VARY BASED UPON FINAL FOOTER HEIGHT.
2) IF LEVEL OF THE EXISTING FLOOR WITHIN THE CHANNEL TROUGH IS NOT WITHIN iFORTRESS' LEVEL TOLERANCE (NOT TO EXCEED 1/4" VARIATION PER OVERALL ASSEMBLED WALL LENGTH), A SELF
LEVELER, SUCH AS QUICKCRETE CAN BE ADDED WITHIN THE 4" SPACE BETWEEN THE CHANNEL PLATES ONLY. THIS COULD EFFECT FINAL DOOR SILL HEIGHT.
EXTERIOR DOUBLE DOOR PANEL ELEVATION
N.T.S.
INTERIOR SINGLE DOOR PANEL ELEVATION
N.T.S.
EXTERIOR DOOR COMPONENT LIST:
(1) 1 pc. S. Parker Hardware SL8160 Series Heavy
Duty Cylindrical Leverset
(2) 3 pc. Five Knuckle Ball Bearing Hinges 4
" x 4
(3) 1 pc. S. Parker 900 Series Door Closer
(4) Silicon Smoke Seals
(5) 5" Widex
" High Saddle Threshold
(6) Vinyl Bottom Door Sweep
(7)
" x
" Astragal (Double Door Only)
(8) Manual Flush Bolt (Double Door Only)
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF DEFENSE AND
U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR
TRAINING DURING THE PERFORMANCE OF A GOVERNMENT CONTRACT, DETERMINED
DECEMBER 5, 2017. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO USAF
AFMC AFLCMC/WNS.
B
A
A
C
SECTION - C
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
S.07
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
iPassage STC 50
DOOR DETAILS
SECTION - A
SECTION - B
DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF
DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A
C_SEGT
C_TEGT
C_TEET
C_SGGTC_SGGS
C_TGGS
C_TGES C_TGET
C_TGGT
TYPICAL JOINT SHIELD CONFIGURATIONS
N.T.S.
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
CEILING PANEL DETAILS
D.01
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF
DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A
GROOVE
GROOVE
STARTER/ENDER
STARTER/ENDER
TONGUE/GROOVE
TONGUE/GROOVE
STARTER/ENDER
(FASCIA)
STARTER/ENDER
(FASCIA)
WITH PANEL NAMING CONVENTIONS
N.T.S.
PANEL NAMING CONVENTIONS
N.T.S.
DIMETRIC VIEW OF C_SGGS CEILING PANEL
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
CEILING PANEL DETAILS
D.02
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF
DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A
CAMPORT OPENING
" #11 THREAD COUNT
THROAT DEPTH = 1-
" [0.029 m]
(TYP)
1'-0
[0.316 m]
VARIES
[0.294 m]
2'
[0.610 m]
(TYP)
1'-10
[0.573 m]
2'
[0.610 m]
(TYP)
1'-0
[0.316 m]
2'
[0.610 m]
(TYP)
C_SEGT
C_TEGT
C_TEET
C_SGGT C_SGGS
C_TGGS
C_TGESC_TGET
C_TGGT
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
CEILING CAMPORT DETAILS
D.03
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF
DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A
[0.294 m]
2'
[0.610 m]
(TYP)
1'-0
[0.316 m]
[0.037 m]
1'-4
[0.417 m]
2'
[0.610 m]
(TYP)
VARIES
2'
[0.610 m]
(TYP)
[0.202 m]
[0.140 m]
[0.268 m]
[0.192 m]
CAMPORT OPENING
" #11 THREAD COUNT
THROAT DEPTH = 1-
" [0.029 m]
(TYP)
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
WALL CAMPORT DETAILS
D.04
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF
DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A
4"
[0.102 m]
12'
[3.658 m]
JOINT SHIELD
(TYP)
1'-11
[0.609 m]
1'-11
[0.609 m]
2'-0
[0.628 m]
4"
[0.102 m]
12'
[3.658 m]
EXTERIOR
SKIN
INTERIOR
SKIN
MALE CAMLOCK
FEMALE
CAMLOCK
INTERIOR WALL PANEL SURFACE
PREFINISHED WITH PROTECH #PS111W9
POWDER - HIGH REFLECTANCE WHITE
4"
[0.102 m]
ISOMETRIC VIEW OF PANEL
N.T.S.
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
WALL PANEL DETAIL
D.05
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF
DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A
12'
[3.658 m]
JOINT SHIELD
(TYP)
1'-11
[0.609 m]
1'-11
[0.609 m]
2'-0
[0.628 m]
4"
[0.102 m]
12'
[3.658 m]
PORTAL ASSEMBLY
ATTACHED TO PANEL SKIN
11'-0
[3.364 m]
1'
[0.304 m]
6" x 6" [0.152 m x 0.152 m] OPENING
INTERIOR
SKIN
MALE CAMLOCK
FEMALE
CAMLOCK
1'
[0.305 m]
NEMA 3R ENCLOSURES WIEGMANN MANUFACTURING OR EQUAL
SCREW COVER W/ 4 HOLES ON BACK
1'-4"
[0.406 m]
6"
[0.152 m]
EXTERIOR
SKIN
INTERIOR WALL PANEL SURFACE
PREFINISHED WITH PROTECH #PS111W9
POWDER - HIGH REFLECTANCE WHITE
4"
[0.102 m]
ISOMETRIC VIEW OF PANEL
N.T.S.
NOTES:
THE JUNCTION BOX WILL BE MOUNTED ON THE WALL PANEL BY AN AUTHORIZED INSTALLER ONLY WITH FOUR (4) SCREWS
AND A SEALANT THAT WILL BOND THE BOX TO THE PANEL.
FOLLOWING THE INSTALLATION OF THE JUNCTION BOXES, THE EXTERIOR SURFACES OF THE JUNCTION BOXES AND PANELS
ARE COATED WITH FIBERTECH F50 PENETRATING-PRIMER FOLLOWED BY FIBERTECH F51 SEALER-COAT.
JUNCTION BOX - EXTERIOR NEMA 3R
6” EXTERIOR PORTAL - RSC101006 - 10 X 10 X 6
9” EXTERIOR PORTAL - RSC121210 - 12 X 12 X 10
12” EXTERIOR PORTAL - RSC161610 - 16 X 16 X 10
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
6" HIGH PORTAL PANEL
DETAIL
D.06
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
DISTRIBUTION STATEMENT D. DISTRIBUTION
AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.
DoD CONTRACTORS ONLY, NECESSARY FOR
OPERATION, MAINTENANCE, INSTALLATION, OR
TRAINING DURING THE PERFORMANCE OF A
GOVERNMENT CONTRACT, DETERMINED DECEMBER
5, 2017. OTHER REQUESTS FOR THIS DOCUMENT
SHALL BE REFERRED TO USAF AFMC AFLCMC/WNS.
12'
[3.658 m]
JOINT SHIELD
(TYP)
1'-11
[0.609 m]
1'-11
[0.609 m]
2'-0
[0.628 m]
4"
[0.102 m]
12'
[3.658 m]
[0.294 m]
EXTERIOR
SKIN
INTERIOR
SKIN
MALE CAMLOCK
PORTAL ASSEMBLY
ATTACHED TO PANEL SKIN
6" x 6" [0.152 m x 0.152 m] OPENING
[0.218 m]
NEMA 3R ENCLOSURES WIEGMANN
MANUFACTURING OR EQUAL
SCREW COVER W/ 4 HOLES ON BACK
1'-4"
[0.406 m]
6"
[0.152 m]
INTERIOR WALL PANEL SURFACE
PREFINISHED WITH PROTECH #PS111W9
POWDER - HIGH REFLECTANCE WHITE
FEMALE
CAMLOCK
4"
[0.102 m]
ISOMETRIC VIEW OF PANEL
N.T.S.
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
6" LOW PORTAL PANEL
DETAIL
D.07
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
NOTES:
THE JUNCTION BOX WILL BE MOUNTED ON THE WALL PANEL BY AN AUTHORIZED INSTALLER ONLY WITH FOUR (4) SCREWS
AND A SEALANT THAT WILL BOND THE BOX TO THE PANEL.
FOLLOWING THE INSTALLATION OF THE JUNCTION BOXES, THE EXTERIOR SURFACES OF THE JUNCTION BOXES AND PANELS
ARE COATED WITH FIBERTECH F50 PENETRATING-PRIMER FOLLOWED BY FIBERTECH F51 SEALER-COAT.
JUNCTION BOX - EXTERIOR NEMA 3R
6” EXTERIOR PORTAL - RSC101006 - 10 X 10 X 6
9” EXTERIOR PORTAL - RSC121210 - 12 X 12 X 10
12” EXTERIOR PORTAL - RSC161610 - 16 X 16 X 10
DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF
DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
iPORTAL™ ASSEMBLY
D.08
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
DISTRIBUTION STATEMENT D. DISTRIBUTION
AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.
DoD CONTRACTORS ONLY, NECESSARY FOR
OPERATION, MAINTENANCE, INSTALLATION, OR
TRAINING DURING THE PERFORMANCE OF A
GOVERNMENT CONTRACT, DETERMINED DECEMBER
MALE CAMLOCKFEMALE CAMLOCK
2'
(TYP)
1'-7
2'
(TYP)
MALE CAMLOCK OF WALL PANEL
INTERLOCKS WITH FEMALE
CAMLOCK IN CEILING PANEL
12'-4"
EXTERIOR SURFACE OF WALL AND
CEILING PANELS ARE COATED WITH
FIBERTECH F50 PENETRATING-PRIMER
FOLLOWED BY FIBERTECH F51
SEALER-COAT FOLLOWING INSTALLATION
INTERIOR SURFACES OF WALL AND
CEILING PANELS ARE PREFINISHED WITH
PROTECH #PS111W9 POWDER - HIGH
REFLECTANCE WHITE. THE INTERIOR
SURFACES OF THE PANELS IN THE
SIMULATOR ROOM WILL BE COMPLETELY
COVERED WITH BLACK, iCOUSTIC PANELS.
NOTES:
PANEL CONNECTIONS ARE MADE BY MALE AND FEMALE
CAMLOCKS MANUFACTURED WITHIN THE PANEL ASSEMBLIES.
MALE CAMLOCKS INTERLOCK WITH THE FEMALE CAMLOCKS
BY MEANS OF THE CAMPORT OPENINGS LOCATED ON THE
INTERIOR OF THE ASSEMBLY.
SEE SHEETS D.03 & D.04 FOR TYPICAL CAMPORT LOCATIONS.
EXTERIOR VIEW OF WALL PANEL CONNECTION
N.T.S.
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
WALL PANEL CONNECTION
AND FINISH DETAIL
D.09
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
DISTRIBUTION STATEMENT D. DISTRIBUTION
AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.
DoD CONTRACTORS ONLY, NECESSARY FOR
OPERATION, MAINTENANCE, INSTALLATION, OR
TRAINING DURING THE PERFORMANCE OF A
GOVERNMENT CONTRACT, DETERMINED DECEMBER
TOP VIEW OF WALL PANEL
MALE CAMLOCK OF WALL PANEL
INTERLOCKS WITH FEMALE
CAMLOCK IN CEILING PANEL
AROUND PERIMETER
1'
2'
(TYP)
FEMALE CAMLOCKMALE CAMLOCK
EXTERIOR SURFACE OF WALL
AND CEILING PANELS ARE
COATED WITH FIBERTECH F50
PENETRATING-PRIMER
FOLLOWED BY FIBERTECH
F51 SEALER-COAT
FOLLOWING INSTALLATION
INTERIOR SURFACES OF WALL AND CEILING
PANELS ARE PREFINISHED WITH PROTECH
#PS111W9 POWDER - HIGH REFLECTANCE WHITE.
THE INTERIOR SURFACES OF THE PANELS IN THE
SIMULATOR ROOM WILL BE COMPLETELY
COVERED WITH BLACK, iCOUSTIC PANELS.
TOP VIEW OF CEILING PANEL CONNECTION
N.T.S.
NOTES:
PANEL CONNECTIONS ARE MADE BY MALE AND FEMALE
CAMLOCKS MANUFACTURED WITHIN THE PANEL ASSEMBLIES.
MALE CAMLOCKS INTERLOCK WITH THE FEMALE CAMLOCKS
BY MEANS OF THE CAMPORT OPENINGS LOCATED ON THE
INTERIOR OF THE ASSEMBLY.
SEE SHEETS D.03 & D.04 FOR TYPICAL CAMPORT LOCATIONS.
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
CEILING PANEL CONNECTION
AND FINISH DETAIL
D.10
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
DISTRIBUTION STATEMENT D. DISTRIBUTION
AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.
DoD CONTRACTORS ONLY, NECESSARY FOR
OPERATION, MAINTENANCE, INSTALLATION, OR
TRAINING DURING THE PERFORMANCE OF A
GOVERNMENT CONTRACT, DETERMINED DECEMBER
AA
CAMPORT OPENING
" #11 THREAD COUNT
THROAT DEPTH = 1-
(TYP)
U-STRUT CHANNEL
NOTES:
U-STRUT CHANNEL TO BE ATTACHED TO WALL AND CEILING
PANELS UTILIZING THE CAMPORT OPENINGS AND THE
NECESSARY CONNECTING HARDWARE WITH 5/8" #11 THREAD
COUNT.
SEE SHEETS D.03 & D.04 FOR TYPICAL CAMPORT LOCATIONS.
TOP VIEW OF CEILING PANEL CONNECTION
N.T.S.
U-STRUT MOUNTING DETAIL
N.T.S.
SECTION A-A
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
U-STRUT MOUNTING
DETAIL
D.11
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
SECURE TO PANELS AT CAMPORT OPENINGS USING
-14 x
-11 x 0.656 COARSE THREAD INSERTS AND x 11 x 1 COARSE THREAD SOCKET HEAD CAP
SCREWS TIGHTENED TO 1190 in-lbs TORQUE.
DISTRIBUTION STATEMENT D. DISTRIBUTION
AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.
DoD CONTRACTORS ONLY, NECESSARY FOR
OPERATION, MAINTENANCE, INSTALLATION, OR
TRAINING DURING THE PERFORMANCE OF A
GOVERNMENT CONTRACT, DETERMINED DECEMBER
INSIDE CHANNEL PLATE
"x2"x2"
OUTSIDE CHANNEL PLATE
"x2"x3"
4" STANDARD PANEL DEPTH
1" x
" CLOSED CELL GASKET
(COMPRESSES TO LESS THAN 1/16")
" TAPCON, EMBED 2
" MIN. (TYP.)
#12 HEX HEAD SHEET METAL SCREWS
(EACH SIDE)
" TAPCON, EMBED 2
" MIN.
NEW CONCRETE SLAB BY OTHERS
EXTERIOR SURFACES OF PANELS AND
CHANNEL PLATES ARE COATED WITH
FIBERTECH F50 PENETRATING-PRIMER
(FIELD APPLIED) FOLLOWED BY FIBERTECH
F51 SEALER-COAT (FIELD APPLIED).
4" STEEL TUBE COLUMN
" x 2
" CHANNEL RAIL
END COLUMN BASE PLATE
" SIMPSON TITEN HD SCREW ANCHOR,
EMBED 3" MIN.
1'
CAULK
" 20 GA. COUNTERFLASHING
HIGH BOND TAPE
6"8"
(1) #12 SCREW AT CENTER
(4) #12 SCREWS AT EACH END
INSIDE AND OUTSIDE CHANNEL PLATE
4"
" TAPCON SCREWS. EMBED 2
" MIN.
SCREW AND TAPCON PATTERN
(INSIDE AND OUTSIDE)
NOTES:
1) BUILDING FLOOR LEVEL SPECIFICATION FOR THE CHANNEL PLATE FOOTPRINT ONLY - FROM THE CENTERLINE OF THE CHANNEL TROUGH, AN AREA OF THE BUILDING FLOOR EQUAL TO EIGHTEEN
INCHES WIDE (18" WIDE), NINE INCHES (9") TO EITHER SIDE OF THE CENTERLINE, AND AS LONG AS THE LENGTH OF ALL ASSEMBLED iGUARD ARMOR WALL PANELS™, NOT TO EXCEED
" OVER 8'. IF
DETERMINED AT THE TIME OF THE SITE SURVEY THAT THE DESIGNATED FLOOR AREA IS NOT WITHIN THESE SPECIFIED TOLERANCES AND PRE-INSTALLATION FLOOR PREPARATION WORK IS REQUIRED, THIS WORK CAN BE PROVIDED BY iFORTRESS OR OTHERS AT AN ADDITIONAL COST
2) IF LEVEL OF THE EXISTING FLOOR WITHIN THE CHANNEL TROUGH IS NOT WITHIN iFORTRESS' LEVEL TOLERANCE (NOT TO EXCEED 1/4" VARIATION PER OVERALL ASSEMBLED WALL LENGTH), A SELF
LEVELER, SUCH AS QUICKCRETE CAN BE ADDED WITHIN THE 4" SPACE BETWEEN THE CHANNEL PLATES ONLY. THIS COULD EFFECT FINAL DOOR SILL HEIGHT.
3) TAPCON CONCRETE SCREWS ATTACH CHANNEL PLATES TO EXISTING FLOOR SLAB UTILIZING THE PRE-EXISTING HOLES MANUFACTURED IN THE CHANNEL PLATES.
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
WALL PANEL TO SLAB
DETAIL
D.12
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF
DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A
INSULATION ADHESIVE
" SLOPE CARLISLE SURE-SEAL
TAPERED HP-H POLYISOCYNURATE
CARLISLE SYNTEC LOW VOC
BONDING ADHESIVE
60 MIL EPDM ROOF
MEMBRANE
iGUARD ARMOR CEILING
PANEL
APPROVED FASTENER
WELD
GUTTER
" X 1
" ANGLE
WOOD NAILER
SEALANT
EPDM FLASHING MEMBRANE
46'
[14.021 m]
10'
[3.048 m]
10'
[3.048 m]
8'
[2.438 m]
10'
[3.048 m]
8'
[2.438 m]
TC
FRONT
BACK
LEFT SIDE
SC PC
26'
[7.928 m]
RIGHT SIDE
AC
C8TGGSC8TEGT C0TGGTC0TGGTC0TGGT
C8TGGSC8TEGT
C8TEGT
C8TEGT
C8TEGT
C8TEGT
C8TEGT
C8TEGT
C8TEET
C8SEGT
C8TGGS
C8TGGS
C8TGGS
C8TGGS
C8TGGS
C8TGGS
C8TGES
C8SGGS
C0TGGT
C0SGGT
C0TGGT
C0TGGT
C0TGGT
C0TGGT
C0TGGT
C0TGGT
C0TGET
C0TGGT
C0SGGT
C0TGGT
C0TGGT
C0TGGT
C0TGGT
C0TGGT
C0TGGT
C0TGET
C0TGGT
C0SGGT
C0TGGT
C0TGGT
C0TGGT
C0TGGT
C0TGGT
C0TGGT
C0TGET
C8TGGSC8TEGT C0TGGTC0TGGTC0TGGT
C8TGGSC8TEGT C0TGGTC0TGGTC0TGGT
C8TGGSC8TEGT C0TGGTC0TGGTC0TGGT
WELD OR SCREW 2' ON
CENTER TO JOINT SHIELDS
" HIGH NAILER WITH
FLASHING
PITCH
"/FOOT
2" WELD OR SCREW, 2' ON
CENTER
" HIGH
NAILER
WITH
FLASHING
" x 1
", 14 GAUGE ANGLE
ALONG ROOF PERIMETER
2 X 4 NAILER WITH GUTTER
PITCH
"/FOOT
2 X 4 NAILER WITH GUTTER
ROOF LEADER
(WHERE APPLICABLE)
26'
K STYLE, HIGH BACK
GUTTER SYSTEM
(SEE DETAIL)
ROOFING SYSTEM INSTALLED ON
TOP OF iFORTRESS MODULAR MCF
(SEE DETAIL)
INSULATION TAPERED AT 1/4" PER FOOT
60 MIL EPDM ROOF MEMBRANE
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
ROOF DETAIL FOR
EXTERIOR INSTALLATIONS
D.13
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
ROOF SECTION
N.T.S.
NOTES AND INSTALLATION INSTRUCTIONS:
A SINGLE LAYER OF STANDARD SINGLE PLY ETHYLENE PROPLYLENE DIENE MONOMER (EPDM) MEMBRANE IS LAID OVER THE EXTERIOR SIDE OF ALL CEILING PANELS. LAY THE MEMBRANE IN SITU ONTO
THE DECK FOR MEASUREMENT, WITH ENOUGH MATERIAL EXTENDING BEYOND THE PERIMETERS TO TRIM UP LATER. ROLL HALF THE MEMBRANE BACK TOWARDS THE MIDDLE OF THE ROOF. USING A 9”
EMULSION ROLLER, SQUEEGEE OR SOFT BROOM, APPLY THE WATER-BASED BONDING ADHESIVE (DECK ADHESIVE) ONTO THE SUBSTRATE SURFACE ONLY. IT IS NOT A CONTACT ADHESIVE AND
THEREFORE NONE IS REQUIRED FOR THE EPDM SURFACE ITSELF. THE ADHESIVE SHOULD NOT BE ALLOWED TO FREEZE AND MUST NOT BE APPLIED IF FREEZING TEMPERATURES ARE FORECAST WITHIN
THE FOLLOWING 24 HOUR PERIOD AFTER BONDING.
ONCE APPLIED, THE MEMBRANE CAN BE LAID INTO THE ADHESIVE WHILST STILL WET. ROLL THE MEMBRANE INTO THE ADHESIVE AVOIDING STRESS OR WRINKLES, TAKING CARE TO SPOT ANY DEBRIS THAT
MAY HAVE FALLEN ONTO THE DECK IN THE MEANTIME. ENTRAPPED AIR AND WRINKLES CAN BE REMOVED BY GENTLY SMOOTHING WITH A SOFT BRISTLE BROOM, ADDING MORE PRESSURE WITH EACH
PASS OF THE BROOM. DO NOT STRETCH THE SHEET.
ROLL BACK THE OTHER HALF OF THE MEMBRANE UP TO THE ALREADY APPLIED ADHESIVE AND REPEAT THE PROCEDURE. IT IS IMPORTANT THAT A 6” WIDE STRIP ALONG ALL PERIMETER EDGES ARE
GLUED USING THE YELLOW SOLVENT BASED CONTACT ADHESIVE, THUS ENSURING THE MEMBRANE IS IMMEDIATELY SECURED IN THE EVENT OF STRONG WINDS CAUSING UPLIFT BEFORE THE WATER
BASED DECKING ADHESIVE HAS COMPLETELY BONDED.
ANGLE INSTALLATION PLAN
N.T.S.
NOTE: FOLLOW THE
PROCEDURES FOR WELDING
SHEET METAL (16 GAUGE)
ROOF GUTTER DETAIL
N.T.S.
DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF DEFENSE
AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A GOVERNMENT CONTRACT, DETERMINED DECEMBER 5, 2017. OTHER REQUESTS FOR THIS DOCUMENT SHALL BE
REFERRED TO USAF AFMC AFLCMC/WNS.
4" STANDARD PANEL DEPTH
INSIDE CHANNEL PLATES
(CHISTD) ON BOTH SIDES
CEILING PANEL
CONCRETE SLAB
" x 2
" CHANNEL RAIL
INSIDE CHANNEL PLATES (CHISTD)
ON BOTH SIDES.
#12 HEX HEAD SHEET METAL
SCREWS (EACH SIDE)
" TAPCON SCREWS EMBED
" MIN. (EACH SIDE)
#12 HEX HEAD SHEET METAL
SCREWS (EACH SIDE)
4" STANDARD PANEL DEPTH
INSIDE CHANNEL PLATES
(CHISTD) ON BOTH SIDES
EXTERIOR WALL PANEL
#12 HEX HEAD SHEET METAL SCREWS
(EACH SIDE)
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
INTERIOR WALL DETAIL
D.14
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
SIDE VIEW OF FLOATING WALL PANEL CONNECTIONS
N.T.S.
NOTES:
1) BUILDING FLOOR LEVEL SPECIFICATION FOR CHANNEL PLATE FOOTPRINT ONLY - FROM THE CENTERLINE OF THE CHANNEL TROUGH, AN AREA OF THE BUILDING FLOOR EQUAL TO EIGHTEEN INCHES
WIDE (18" WIDE), NINE INCHES (9") TO EITHER SIDE OF THE CENTERLINE, AND AS LONG AS THE LENGTH OF ALL ASSEMBLED iGUARD ARMOR WALL PANELS™, NOT TO EXCEED
" OVER 8'. IF DETERMINED AT
THE TIME OF THE SITE SURVEY THAT THE DESIGNATED FLOOR AREA IS NOT WITHIN THESE SPECIFIED TOLERANCES AND PRE-INSTALLATION FLOOR PREPARATION WORK IS REQUIRED, THIS WORK CAN BE
PROVIDED BY iFORTRESS OR OTHERS AT AN ADDITIONAL COST
2) IF LEVEL OF THE EXISTING FLOOR WITHIN THE CHANNEL TROUGH IS NOT WITHIN iFORTRESS' LEVEL TOLERANCE (NOT TO EXCEED 1/4" VARIATION PER OVERALL ASSEMBLED WALL LENGTH), A SELF
LEVELER, SUCH AS QUICKCRETE CAN BE ADDED WITHIN THE 4" SPACE BETWEEN THE CHANNEL PLATES ONLY. THIS COULD EFFECT FINAL DOOR SILL HEIGHT.
3) TAPCON CONCRETE SCREWS ATTACH CHANNEL PLATES TO EXISTING FLOOR SLAB UTILIZING THE PRE-EXISTING HOLES MANUFACTURED IN THE CHANNEL PLATES.
TOP VIEW OF FLOATING WALL PANEL CONNECTIONS
N.T.S.
DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF
DEFENSE AND U.S. DoD CONTRACTORS ONLY, NECESSARY FOR OPERATION, MAINTENANCE, INSTALLATION, OR TRAINING DURING THE PERFORMANCE OF A
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
E37
REVISION NOTESREV DATE RP CO
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
ENCLOSURE BONDING AND
GROUNDING DETAIL
D.15
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
DISTRIBUTION STATEMENT D. DISTRIBUTION
AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.
DoD CONTRACTORS ONLY, NECESSARY FOR
OPERATION, MAINTENANCE, INSTALLATION, OR
TRAINING DURING THE PERFORMANCE OF A
GOVERNMENT CONTRACT, DETERMINED DECEMBER
N.T.S.
SECTION A
iGUARD ARMOR PANEL INTERIOR ELEVATIONS
8'-8"
[2.642 m]
6'
[1.829 m]
W
R
O C
S
CBM086B-B
W
R
O C
W
L
O C
S W
L O
C
W
S
T D
S W
S T
D
W
S
T D
S W
S T
D
W
S
T D
S W
S T
D
W
S
T D
S W
S T
D
W
S
T D
S W
S T
D
W
M
H x x x S
W
S
T D
W
S
T D
S W
S T
D
W
S
T D
S W
S T
D
W
S
T D
S W
S T
D
W
H P
S W
S T
D
W
S
T D
S W
S T
D
W
M
H x x x S
W
S
T D
W
S
T D
S W
S T
D
W
S
T D
S W
S T
D
W
L P
S W
S T
D
W
S
T D
S W
S T
D
W
S
T D
S W
S T
D
W
S
T D
S W
S T
D
W
S
T D
S W
S T
D
W
S
T D
S W
S T
D
W
S
T D
S W
S T
D
W
S
T D
S W
S T
D
CBM116-B CBM116-B CBM116-W CBM086A-W
26"
[0.660 m] iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
RP CO
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
iGUARD ARMOR WALL PANELS™
ELEVATION VIEW
SECTION A
I.01
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
REVISION NOTESREV DATE RP CO
E
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
DISTRIBUTION STATEMENT D. DISTRIBUTION
AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.
DoD CONTRACTORS ONLY, NECESSARY FOR
OPERATION, MAINTENANCE, INSTALLATION, OR
TRAINING DURING THE PERFORMANCE OF A
GOVERNMENT CONTRACT, DETERMINED DECEMBER
SECTION B
iGUARD ARMOR PANEL INTERIOR ELEVATIONS
SOUTH
8'-8"
[2.642 m]
6'
[1.829 m]
62 63 64 65 66 67 69 70 71 72 73 7468 75
6149 50 51 52 53 54 55 56 57
W
R
O C
S
W
S
T D
S
W
S
T D
S
W
S
T D
S
W
S
T D
S
W
S
T D
S
W
S
T D
S
W
S
T D
S
W
S
T D
S
W
S
T D
S
W
S
T D
S
W
S
T D
S
W
S
T D
S
W
L
O C
S W
L O
C
W
R
O C
W
S
T D
W
S
T D
W
S
T D
W
S
T D
W
S
T D
W
S
T D
W
S
T D
W
S
T D
D L
D M
F E
DH961900DMF-E
D R
D M
F E
CMB146A-W CBM146B-W
CMB146A-W CBM146B-W
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
RP CO
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
iGUARD ARMOR WALL PANELS™
ELEVATION VIEW
SECTION B
I.02
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
REVISION NOTESREV DATE RP CO
E
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
DISTRIBUTION STATEMENT D. DISTRIBUTION
AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.
DoD CONTRACTORS ONLY, NECESSARY FOR
OPERATION, MAINTENANCE, INSTALLATION, OR
TRAINING DURING THE PERFORMANCE OF A
GOVERNMENT CONTRACT, DETERMINED DECEMBER
SECTION C
iGUARD ARMOR PANEL INTERIOR ELEVATIONS
8'-8"
[2.642 m]
6'
[1.829 m]
101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122
77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98
W R
O C
S W
R
O C
W L O
C S
W L O
C
W S
T D
S
W S
T D
S
W H
P S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
CBM086B-W CBM116-W CBM116-B CBM116-B CBM086A-B
W S
T D
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
RP CO
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
iGUARD ARMOR WALL PANELS™
ELEVATION VIEW
SECTION C
I.03
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
REVISION NOTESREV DATE RP CO
E
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
DISTRIBUTION STATEMENT D. DISTRIBUTION
AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.
DoD CONTRACTORS ONLY, NECESSARY FOR
OPERATION, MAINTENANCE, INSTALLATION, OR
TRAINING DURING THE PERFORMANCE OF A
GOVERNMENT CONTRACT, DETERMINED DECEMBER
SECTION D
iGUARD ARMOR PANEL INTERIOR ELEVATIONS
8'-8"
[2.642 m]
6'
[1.829 m]
139 140 141 142 143 144 145 146 147 148 149 150
125 126 127 128 129 130 131 132 133 134 135 136
W R
O C
S W
R
O C
W L O
C S
W L O
C
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
W S
T D
S
CBM146A-B CBM146B-B
CBM146A-B CBM146B-B
iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
RP CO
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
iGUARD ARMOR WALL PANELS™
ELEVATION VIEW
SECTION D
I.04
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
REVISION NOTESREV DATE RP CO
E
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
DISTRIBUTION STATEMENT D. DISTRIBUTION
AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.
DoD CONTRACTORS ONLY, NECESSARY FOR
OPERATION, MAINTENANCE, INSTALLATION, OR
TRAINING DURING THE PERFORMANCE OF A
GOVERNMENT CONTRACT, DETERMINED DECEMBER
SECTION E
iGUARD ARMOR PANEL INTERIOR ELEVATIONS
8'-8"
[2.642 m]
6'
[1.829 m]
166 167 168 169
153 154 155 156 160
170 171 173 174 175 176 177
163161
157 159
W F
E L S
C
O W
F
E L C
O
W F
E R
S C
O W
F
E R
C
O
W H
P S
F
L T
W H
P S
F
L T
W H
P S
F
L T
W M
H x x x S
F
L T
W S
T D
F
L T
W S
T D
F
L T
W S
T D
F
L T
W S
T D
F
L T
W S
T D
F
L T
W H
P S
F
L T
W S
T D
S F
L T
W S
T D
S F
L T
W S
T D
S F
L T
W S
T D
S F
L T
W S
T D
S F
L T
W S
T D
S F
L T
W S
T D
S F
L T
D R
S
T C
D L S
T C
D L M
F
D R
M
F
CBM304
DH721900MF
DH961900STC
26"
[0.660 m] iFORTRESS
SHIP TO:
L A
N
J O
B
N
O
GENERATED IN AUTOCAD
DO NOT SCALE DRAWING
IMPORTANT NOTE: ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL
WOODLAND PARK, NEW JERSEY
2 3 4 5 6
A
2 3 4 5 6
B
C
D
A
B
C
D
END USER ACCEPTANCE DATE INTEGRATOR ACCEPTANCE DATE
RP CO
DATE
SCALE SHEET SIZE DRAWING NO. REV.
NONE BOF
iGUARD ARMOR WALL PANELS™
ELEVATION VIEW
SECTION E
I.05
SPECIFICATION REQUIRED WITH SIGNED DRAWINGS
PLEASE SEE SHEET S.01
INTEGRATOR
USAF JTC RSS
Model i-TCO-01196-14EXT
9/15/17
REVISION NOTESREV DATE RP CO
E
RELOCATE CONFERENCE ROOM DOORA 10/17/17 RP
REVISIONS PER AIR FORCE COMMENTSB 10/25/17 RP
REVISIONS PER AIR FORCE COMMENTSC 11/8/17 RP LAN
REVISIONS PER AIR FORCE COMMENTSD 11/20/17 MMW LAN
LAN
LAN
REVISIONS PER AIR FORCE COMMENTSE 12/04/17 RP LAN
DISTRIBUTION STATEMENT D. DISTRIBUTION
AUTHORIZED TO DEPARTMENT OF DEFENSE AND U.S.
DoD CONTRACTORS ONLY, NECESSARY FOR
OPERATION, MAINTENANCE, INSTALLATION, OR
TRAINING DURING THE PERFORMANCE OF A
GOVERNMENT CONTRACT, DETERMINED DECEMBER
SECTION F
iGUARD ARMOR PANEL INTERIOR ELEVATIONS
8'-8"
[2.642 m]
6'
[1.829 m]
184179
185 186 187 188 189
W F
E R
S C
O W
F
E R
C
O
W F
E L
W F
E L S
W S
T D
S F
L T
W H
P S
F
L T
W H
P S
F
L T
W S
T D
S F
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.