Attachment 9 Architectural Compatability 18 Dec 2003.pdf

PDF 3 MB Posted

Attached to
Simplified Acquisition of Base Engineering Requirements (SABER) VIII Federal contract opportunity
Solicitation number
FA4809-10-R-0001
Issued by
Department of the Air Force Air Combat Command

About this file

Attachment 9 Architectural Compatibility Standards Sep 2003 22 pages

View the file

Other files for this federal contract opportunity

Other files attached to Simplified Acquisition of Base Engineering Requirements (SABER) VIII, newest first.
File Type Posted
Amendment 0005 correcting Amendment 0004.pdf PDF
Additional Questions and Answers 17 May 2010.docx DOCX document
Section J.dot DOT file
Amendment 0004.rtf RTF text file
J. Atch 8 - Project History.doc DOC document
Amendment 0003.pdf PDF
Site Visit Minutes with Attachments.pdf PDF
Amend 02 SABER VIII.doc.pdf PDF
SABER VIII Offeror Questions.doc DOC document
Amendment 0001 SABER VIII.doc DOC document
I. Atch 7 - AF FORM 66.XLS XLS spreadsheet
F. Atch 4 - Deter. of Ktr. Respons..doc DOC document
D. Atch 2 - 10 WDs Consolidated.docx DOCX document
G. Atch 5 - Demonstration Project.pdf PDF
J. Atch 8 - Project History.doc DOC document
E. Atch 3 - Past Performance Questionnaire w Cvr Ltr.doc DOC document
H. Atch 6 - Location Plan SABER VIII.pdf PDF
B. Solicitation No. FA4809-10-R-0001 SABER VIII.rtf RTF text file
C. Atch 1 - Environmental Protection Specs.doc DOC document
A. Cover Sheet and Instructions for RFP IFB.doc DOC document
Show all 20

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ARCHITECTURAL

COMPATIBILITY STANDARDS

Seymour Johnson Air Force Base

North Carolina

September 2003

AIR COMBAT COMMAND

UNITED STATES AIR FORCE

CONTENTS

Architectural Compatibility Standards - Seymour Johnson AFB, NC i

1.0.0 EXECUTIVE SUMMARY

2.0.0 INTRODUCTION

2.1.0 Scope of Document

2.2.0 Review and Compliance

2.3.0 Base Mission

2.4.0 Regional Setting

3.0.0 ARCHITECTURAL CHARACTER

3.1.0 Goals

3.1.1 Creation of a Corporate Image

3.1.2 Development of a Campus Atmosphere

3.1.3 Response to Regional Architecture

3.1.4 Integration of New Architectural

Standards with Existing Conditions

4.0.0 VISUAL AREAS

4.1.0 Community Area

4.2.0 Summary of Design Guidelines

4.3.0 Mission/Industrial Area

4.4.0 Summary of Design Guidelines

4.5.0 Family Housing Area

4.6.0 Summary of Design Guidelines

(Non-housing Facilities)

4.7.0 Summary of Design Guidelines

(Housing Units)

5.0.0 ARCHITECTURAL

5.1.0 General

5.2.0 Site Planning

5.3.0 Building Form

5.4.0 Roofs

5.5.0 Entrances

5.6.0 Fascias and Soffits

5.7.0 Exterior Walls

5.8.0 Windows and Doors

5.9.0 Finish Hardware

6.0.0 SITE DESIGN

6.1.0 Vehicular Circulation

6.2.0 Parking

6.3.0 Pedestrian Circulation

6.4.0 Site Lighting

6.5.0 Fences and Screens

6.6.0 Site Furnishings

7.0.0 LANDSCAPE

7.1.0 General

7.2.0 Regional Design

7.3.0 Energy Conservation

7.4.0 Street Trees

7.5.0 Parking Lot Landscaping

7.6.0 Visual Screening

7.7.0 Foundation Planting

7.8.0 Courtyards and Entrances

7.9.0 Landscape Materials

8.0.0 SIGNAGE

8.1.0 Exterior Signs

8.1.1 General

8.1.2 Building and Organization

Identification Signs

8.1.3 Directional Signs

8.1.4 Regulatory Signs

8.1.5 Information and Motivation Signs

8.2.0 Interior Signs

8.2.1 General

8.2.2 Information Signs

8.2.3 Identification Signs

8.2.4 Directional Signs

8.2.5 Regulatory Signs

9.0.0 SELF-HELP

9.1.0 General

9.2.0 The Self-help Process

A.0.0 APPENDIX

A.1.0 ACC Architectural and Interior

Design Standards

EXECUTIVE SUMMARY

Architectural Compatibility Standards - Seymour Johnson AFB, NC 1-1

1.0.0 Executive Summary

The primary purpose of the Seymour Johnson Architectural Compatibility Standards is to establish guidelines that will create a unified visual character for the entire installation. Architectural compatibility focuses on harmony of all of the components that shape the appearance of the base.

This includes, but is not limited to, building form, color and type of materials, landscaping, site furnishings, site design, and signage.

The Architectural Compatibility Standards organizes the physical environment at Seymour Johnson into three visual areas: the Community Area, the Mission/Industrial Area, and the Family Housing Area. Each visual area is defined by current land use and by the proposed architectural theme and materials for the area. (Figure 1-1A)

The Community Area is the area along Wright Brothers Ave. from the main gate to Goodson Street, extending south to Blakeslee Avenue and east to Vermont Garrison Street. It contains the dormitories, community center, shopping, recreation, medical and worship facilities. For most visitors, it is the first impression they receive of the base.

Most of the buildings in this area are one or two-story masonry in various shades of red and brown brick. Some of the newer buildings have dark bronze sloped metal roofs; many of the older buildings have flat roofs with dark bronze trim.

Recent renovations in the Community Area have used materials that reinforce the theme of red brick and sloped dark bronze metal roofs.

The image for this area should be one of quality and permanence and emphasize the importance of the pedestrian. It should take on the characteristics of a campus environment through use of similar materials, well maintained grounds, walkways, and outdoor spaces. It is important to site buildings with the front facade to the main street and provide

VISUAL

AREAS

MATERIALS C

O

M M

U N

IT

Y

M

IS

SI

N

H

U

SI

N G

Red Brick X *

Textured CMU – Beige X

W A

LL

Metal Siding – Beige X

Standing Seam Metal - Dark Bronze X X

R O

O F

Asphalt Shingles *

Metal Doors – Dark Bronze X X

Aluminum Windows – Dark Bronze X X

Metal Trim – Match Door Color X X

D O

O R

S

W

IN

D O

W S

Doors, Windows, Trim on Family Housing facilities *

* Refer to Housing Community Plan for approved color and material schemes.

1-1A Exterior Material Matrix

1-1B Zone Map

Mission/Industrial Area

Community Area Family Housing Area

Architectural Compatibility Standards - Seymour Johnson AFB, NC 1-2 prominent entrances. Parking should not occupy the space between the main street and the front facade. The buildings shall be constructed of red brick with dark bronze sloped metal roofs. All buildings will be no more than two stories, except for dormitories, which may be three. Landscaping should complement a building’s function, reserving ornamental plantings for prominent buildings. It is also important to provide street trees along main roads and to screen obtrusive elements such as parking and transformers.

The Mission/Industrial Area comprises the largest land area on base. It surrounds the Community Area on the north, south and west. Facilities in this area range from small storage buildings (Figure 1- 2A) and operations buildings (Figure 1-2B), to administrative buildings, warehouses and hangars.

Many different materials were used to construct the existing facilities in the Mission/Industrial Area.

Metal wall and roof panels in beige and brown tones are the predominant materials for large warehouses and hangar buildings. Materials for other buildings include beige textured concrete masonry and exposed aggregate precast concrete panels. Existing roofs include flat roofs and sloped dark bronze metal roofs, some with large turned-down fascias. Visual unity can be enhanced by standardizing the palette of materials and colors.

Exterior walls of future buildings in the Mission/ Industrial Area will be constructed of textured concrete masonry units, similar in color to those used on the Air Force Reserves Recruiter (Figure 1-2C). Sloped roofs of dark bronze standing seam metal will be used to visually link the buildings to those of the adjacent Community Area. With the approval of the ACC Command Architect and the Base Civil Engineer, metal wall panels may be used on hangars and large industrial facilities. The color of metal wall panels will be beige to match Federal Standard 595b color #23617. All metal buildings will have a concrete masonry base with the height proportional to the size of the building, but not less than four feet high.

1-2A Publications and Distribution Office, Building

1-2B 333rd Fighter Squadron Ops

1-2C Reserves Recruiter Building

Architectural Compatibility Standards - Seymour Johnson AFB, NC 1-3

The Family Housing Area, located on the eastern side of the base, is adjacent to the Community Area and the main gate. Recent renovations have upgraded much of the housing with red brick, vinyl siding, and asphalt shingle roofs. This theme should continue throughout the zone. Non-housing facilities built within this area should be limited to two-story construction of red brick, with a dark bronze sloped metal roof. Landscaping should emphasize low maintenance, native plant materials.

1-3A Berkeley Village, Family Housing (Old Capehart Style above)

1-3B Berkeley Village, Family Housing (Recently Renovated)

INTRODUCTION

Architectural Compatibility Standards - Seymour Johnson AFB, NC 2-1

2.0.0 Introduction

2.1.0 Scope of the Document

The Architectural Compatibility Standards establishes guidance for design and construction at Seymour Johnson Air Force Base. Guidelines contained in the document are specifically designed to create a unified architectural character for the entire installation.

This document is intended for use by military, DoD civilian personnel, and private sector firms involved in all phases of facility planning, maintenance and repair, design, and construction. Base personnel should refer to this manual when planning or designing new buildings, additions, self-help work orders, or maintenance and repair work orders for existing buildings. Private sector firms contracted to provide professional architectural or engineering services should use the standards throughout the design process to produce work that blends and complements the environment at Seymour Johnson

AFB.

2.2.0 Review and Compliance

All projects, in-house work orders, and self-help work orders will include an architectural review by the Base Civil Engineer. Designers of self-help projects should meet with the Base Civil Engineering representative at the beginning of a project. All other projects will include an architectural review at the 35% preliminary design submittal. Proposed designs that do not comply with the Seymour Johnson Architectural Compatibility Standards require approval from the Base Civil Engineer.

Proposed designs that do not comply with the ACC Architectural and Interior Design Standards require a waiver from the ACC Command Architect (ACC/CEPT). If waiver is not granted, projects must be redesigned to comply. Requests for waivers must be submitted no later than the 35% Preliminary Design Submittal or prior to the start of self-help projects.

2-2A F-15E Static Display

2.3.0 Base Mission

The 4th Fighter Wing is host unit at Seymour Johnson AFB. The wing’s mission is to generate airpower, put bombs on target, and train F-15E aviators. The wing accomplishes its operational and training missions with the F-15E Strike Eagle aircraft. A dual-role fighter, the F-15E can fight its way to a target over long ranges, destroy enemy ground targets then fight its way out.

The 4th Fighter Wing is composed of four fighter squadrons, 333rd, 334th, 335th and 336th. Two of the wing’s squadrons are assigned the mission of training all F-15E aircrews for the Air Force. The other two are operational squadrons.

The 916th Air Refueling Wing, is an Air Force Reserve tanker unit located at Seymour Johnson AFB. The peacetime mission of the 916th ARW is to develop and maintain the operational capability of its subordinate units and to train reservists for worldwide duty. In the event of war or national emergency, the 916th ARW will fall under the direction of the Air Mobility Command, Scott AFB, Illinois.

The wing has 12 subordinate units, including the 916th Communications Flight, the 916th Medical Squadron and three groups of squadrons and flights: 916th Logistics Group, 916th Operations Group and 916th Support Group.

Architectural Compatibility Standards - Seymour Johnson AFB, NC 2-2

2.4.0 Regional Setting

2.4.1 Geography

Seymour Johnson Air Force Base occupies 3,233 acres (5 square miles) of land within the city limits of Goldsboro, North Carolina. It is approximately 50 miles southeast of Raleigh, on the Neuse River.

Highway 70 runs north of the base and Highway 117 lies to the west of the base. The current population of Goldsboro is about 48,000, and the population of surrounding Wayne County is approximately 110,000. Residential, agricultural, commercial, and industrial land uses occur adjacent to the installation.

2.4.2 Topography

Seymour Johnson is located on relatively flat land at the center of the coastal plain of eastern North Carolina, approximately 65 miles from the Atlantic Ocean. The topography includes the floodplain of the Neuse River, a higher terrace of the river, and a still higher terrace that may also be of riverine origin.

As in most Coastal Plain river valleys, the Neuse River valley is not symmetrical. The river flows along the south side of the watershed with the southern drainage divide located about four miles to the southwest. The northern divide lies many miles to the north. The south side of the valley, across the river from the base, is narrow with an abrupt, relatively steep slope to the uplands. The north side, where Seymour Johnson is located, rises very gradually, without a clear edge to the valley.

Elevations on the base vary from approximately 45 to 110 feet, gradually sloping downward from northeast to the southwest. The greatest relief is along Stoney Creek, where it flows through the higher terrace. Refer to the General Plan for flood zone information.

2-3A Regional Map

Architectural Compatibility Standards - Seymour Johnson AFB, NC 2-3

2.4.3 Soils

A soil survey of Wayne County indicates the presence of fifteen different soil series on base, reflecting the differing ages of the landscape and the variety of soil drainage created by the topography.

Geo-technical investigation is required for all subsurface design.

2.4.4 Climate

Eastern North Carolina has a temperate climate with long, humid summers and short, mild winters with frontal storm systems and cold spells. Precipitation averages 50 inches annually, with the greatest monthly rainfall occurring in the spring. Snow is infrequent.

Seymour Johnson’s location, near the Atlantic Coast, creates the potential for serious damage due to hurricanes and tropical storms. Hurricane season runs from June to November.

• Latitude = 35°20’ North

• Longitude = 77°50’ West

• Altitude above Sea Level = 100 feet

• Winter outdoor design temperature = 22°

• Heating degree days = 3191 (based on 65°)

• Sun altitude angle: Noon on Dec. 21 = 31° Noon on June 21 = 77°

• USDA Plant Hardiness Zone 8

2-4A Solar Altitude Angles

2.4.5 Response to Climate

In Seymour Johnson’s humid southern climate, a primary design objective is to minimize summer solar gain. In winter, heat loss should be minimized and solar gain should be used to advantage.

Design strategies include shading building walls and roofs with deciduous trees on south, east and west sides, providing ample roof and crawl space ventilation, and orienting the building to benefit from summer breezes.

Another effective strategy for roof space ventilation is the use of ridge vents. Thermally massive envelope materials, such as masonry walls, may be used to reduce peak air conditioning loads by delaying peak heat gain.

Building openings should be protected from summer sun by using a combination of high performance glazing and traditional southern methods of porches, roof overhangs, and colonnades.

ARCHITECTURAL CHARACTER

Architectural Compatibility Standards - Seymour Johnson AFB, NC 3-1

3.0.0 Architectural Character

3.1.0 Goals

The design guidelines in this document have been developed in response to four principal goals:

• Create buildings which project a corporate image for the Air Force

• Develop a campus atmosphere at Seymour Johnson

• Establish a style which responds to the architectural context of the region

• Create architectural standards that are compatible with the existing built and natural environment

3.1.1 Creation of a Corporate Image

“Corporate image” can be interpreted in a variety of ways. The design guidelines have been formulated to express an architectural character that projects an image of efficiency and permanence. Common building forms and materials will allow individual buildings to appear as part of a larger whole.

Logical vehicular circulation and an emphasis on creating highly visible building entrances will help develop the image of buildings within a corporate office park.

“Corporate image” includes worker satisfaction as a priority. The design guidelines contain provisions for operable windows in all offices and living areas.

The addition of site lighting, site furnishings and outdoor break areas will also benefit building occupants.

Carefully designed landscaping is one of the most effective means of achieving visual harmony on a basewide scale. A base street tree program can mitigate the negative impact of older, incompatible buildings. Landscape guidelines that encourage use of a limited number of regionally suitable species will help unify the entire base.

3-1A Base Main Entrance Sign

Architectural Compatibility Standards - Seymour Johnson AFB, NC 3-2

3.1.2 Development of a Campus Atmosphere

Focus on the pedestrian is key to the creation of a campus environment. The design guidelines propose methods for mitigating the negative impact of the automobile by separating parking from building entrances and linking buildings with shaded pedestrian paths. A carefully designed network of paths connecting living, working, shopping and recreational facilities will increase pedestrian activity and help to overcome the perception that “it’s too far to walk.”

Successful campus buildings have clearly defined entrances and often include arcades and courtyards that provide gathering places for recreation and socializing. These features are encouraged. The recommended building materials and fenestration patterns are designed to provide human scale on all buildings, another feature common to successful campus architecture.

3.1.3 Response to Regional Architecture

Since the 18th century, settlers in eastern North Carolina have adapted buildings to the local climate of hot, humid summers and temperate winters by incorporating moderately pitched roofs and large deep porches to provide protection from the summer sun. Buildings were constructed of locally harvested woods and brick made from local clays.

As in the other original colonies, early roofing materials were wood shingles; as technology developed, many structures incorporated metal roofing (Figure 3-2B).

Many of the design concepts of colonial architecture are still important today. Thick masonry walls help keep dwellings cool in summer by slowing heat transfer, and operable windows can be used to provide natural ventilation. One and two-story buildings with sloping metal roofs, entrance porches, and walls of locally manufactured masonry continue the tradition of an architectural style which developed in response to the local environment.

3-2A Dining Facility

3-2B House near Hertford NC circa 1800. The Tudor Manor House of New England is adapted to the southern climate through use of a shallow pitched roof and a two-story, metal-roofed porch.

Architectural Compatibility Standards - Seymour Johnson AFB, NC 3-3

3.1.4 Integration of new architectural

standards with existing conditions

The Seymour Johnson Architectural Compatibility Standards have been developed acknowledging that most facilities on base will remain in use for many years. A major objective of the document is to establish guidelines that allow new facilities, additions, and renovations to existing buildings to be visually compatible.

In the past, base leadership has followed a plan to use red brick and dark bronze metal roofs on dormitories, community buildings, and other facilities in the central part of the base (Figure 3- 3A). A Community Center Plan has been created by the Harris Group, Reston, VA, to guide future development in this area. The Architectural Compatibility Standards supports this vision of the Community Area.

A wider variety of architectural styles and building materials are found on existing facilities in the Mission/Industrial area surrounding the Community Area. To achieve architectural compatibility in this zone, the development guidelines will limit material choices. Future materials will harmonize with the prevailing beige and brown color scheme, and will be selected based on durability, economy, and aesthetic aspects.

3-3A Renovated dormitories and many other facilities in the Community Area make use of red brick walls and dark bronze metal roofing.

3-3B Constructed of beige split-face concrete masonry with dark bronze metal roof, the 916th Wing Headquarters is an example of compatible development in the Mission/Industrial area.

VISUAL AREAS

Architectural Compatibility Standards - Seymour Johnson AFB, NC 4-1

4.0.0 Visual Areas

Don’t print this page. Page 4-1 is included as a separate file (sect-4-1.doc) on the CD.

COMMUNITY AREA

Architectural Compatibility Standards - Seymour Johnson AFB, NC 4-2

4.1.0 Community Area

The Community Area comprises the main cantonment area of the base. Nearly all of the functions of a small city are represented in this zone, including living, working, recreation, medical, shopping, and worship facilities. It is the most public-oriented area and the first image of the base for most visitors.

The majority of the buildings in this zone are one and two-story masonry in various shades of red and brown brick. Other existing materials include light colored concrete masonry, and metal panel siding.

Newer buildings have dark bronze sloped metal roofs. Many of the older buildings have flat roofs with either a small fascia or a larger turned down fascia in dark brown tones. There has been a recent effort to renovate and construct buildings using red brick and sloped standing seam metal roofs in dark brown shades.

4-2A Golf Clubhouse

4-2B Chapel

Architectural Compatibility Standards - Seymour Johnson AFB, NC 4-3

4.2.0 Summary of Design Guidelines for the

Community Area

4.2.1 Site Planning

• Focus on pedestrian circulation.

• Site new facilities in accordance with the

Community Center Master Plan.

4.2.2 Building Form

• Maximum height for all buildings except dormitories, is two stories. Dormitories may be three stories.

• Building entrances should be easily visible from the street and parking areas.

• Arrange building forms to create pedestrian spaces such as arcades and courtyards.

4.2.3 Roofs

• Dark bronze standing seam metal roofs with minimum 3:12 pitch. Lesser pitch may be used on large buildings with approval of the Base Civil Engineer and ACC Command Architect. Color shall match Petersen Aluminum Corp (PAC-CLAD) “Dark bronze.”

4.2.4 Exterior Walls

• Red brick with off-white mortar, similar to that used on the existing commissary, housing office, and renovated dormitories (Figures 4-3A, 4-3B, 4-3C). Brick shall match Pine Hall, standard modular size, “Old Colony/Light Range,” modular face brick.

• Thin brick veneer over an existing masonry substrate, as used on the 4th Wing Headquarters and Support Group Headquarters, may be used on renovation projects with approval of the Base Civil Engineer.

• Brick detailing such as soldier courses, reveals and special brick shapes is encouraged.

• Accent materials such as cast stone or additional brick colors are encouraged and may be used with approval of the Base Civil Engineer.

4-3A Housing Office

4-3B Renovated Dormitory

4-3C Commissary

Architectural Compatibility Standards - Seymour Johnson AFB, NC 4-4

4.2.5 Trim

• Metal fascia and gutters shall match metal roof color. Downspouts shall match color of adjacent wall surface or fascia color.

4.2.6 Doors and Windows

• Aluminum windows and storefront shall be dark bronze anodized or shall have a fluoropolymer finish to match metal roof color. (Figure 4-4A).

• Hollow metal doors shall match color of metal roof and trim.

4-4A Dark bronze aluminum windows match the metal roof. Brick detailing at window head and floor line adds interest.

MISSION/INDUSTRIAL

Architectural Compatibility Standards - Seymour Johnson AFB, NC 4-5

4.3.0 Mission/Industrial Area

The Mission/Industrial Area surrounds the Community Area on three sides. It includes facilities that are dedicated to the mission of the base: aircraft runway and flight line activities, squadron buildings, munitions facilities, small arms range, maintenance facilities, industrial and storage buildings, and the 916th Air Refueling Wing complex.

Existing structures range in size from small storage buildings to large warehouses and hangars. Most of the larger buildings have metal wall and roof panels in beige and brown tones. The remainder of the buildings are predominantly light colored concrete masonry, including ribbed and split face units, and painted concrete masonry. Some of the small storage buildings and a few of the operations buildings are constructed of light colored exposed aggregate precast concrete panels. Existing roofs include flat roofs and sloped dark brown metal roofs, some with a large turned down fascia.

A renovation to the 916th Fuel Shop has added one-story concrete masonry wings to the large metal building, giving the large structure a more human scale. The split face block visually integrates the building with adjacent facilities and provides a durable finish at ground level (Figure 4-5C).

Located within this zone is a minimum-security federal prison camp that leases the land from the base. Completed in 1991, the compound’s buildings are light-colored exterior insulation and finish system with sloped metal roofs that blend in well with the surrounding architecture of the base.

More than 500 inmates supplement the work force for the base, helping to maintain the grounds and facilities.

4-5A Base Operations

4-5B Hangar

4-5C 916th Fuel Shop

MISSION/INDUSTRIAL

Architectural Compatibility Standards - Seymour Johnson AFB, NC 4-6

4.4.0 Summary of Design Guidelines for

the Mission/Industrial Area

4.4.1 Building Form

• Use simple, functional forms for industrial/operational buildings. On more people-oriented facilities, arrange building forms to create pedestrian spaces.

4.4.2 Roofs

• Dark bronze standing seam metal roofs with minimum 3:12 pitch. Lesser pitch may be used on large buildings with approval of the Base Civil Engineer. Color shall match Petersen Aluminum Corporation (PAC- CLAD) “Dark bronze.”

• For energy efficiency, very large buildings may use Fed. Std. 595b #23617 beige for metal roofs with approval of the Base Civil Engineer and ACC Command Architect.

4.4.3 Exterior Walls

• Predominant wall material shall be integrally colored split-face concrete masonry units. Color shall match Adams A815W “Ivory.” Other concrete masonry textures may be used as accents.

• Prefinished metal wall panels may be used on hangars and large industrial buildings with approval of the ACC Command Architect and the Base Civil Engineer.

Metal buildings shall have a split-face concrete masonry base with the height proportional to the building size, but not less than four feet high. Color of metal panels shall be beige to match Fed. Std. 595b #23617. Refer to Section 5.7.1 for additional requirements for use of metal panels.

4.4.4 Trim

• Metal fascia and gutters shall match metal roof color. Downspouts shall match color of adjacent wall surface or fascia and gutter color.

4.4.5 Doors and Windows

• Aluminum windows and storefront shall be dark bronze anodized or shall have fluoropolymer finish to match dark bronze metal roof color.

• Hollow metal doors shall match color of dark bronze metal roof.

4-6A Split-face concrete masonry and dark bronze metal roofs are the standard for the Mission/Industrial area.

4-6B Reserves Recruiter Building

FAMILY HOUSING

Architectural Compatibility Standards - Seymour Johnson AFB, NC 4-7

4.5.0 Family Housing Area

The Family Housing Area is located on the eastern side of the base, adjacent to the Community Area and the main gate. It is composed almost entirely of accompanied housing. Recent renovations have improved both the architecture and the landscaping in this area. Most units are red brick with gently sloping asphalt shingle roofs (Figure 4-7A, 4-7B, 4-7C).

Military Family Housing is subdivided into three areas on base: Wayne Manor, Berkeley Village, and the Mobile Home Park. Wayne Manor and Berkeley Village total 1,698 units, including 154 units for officers and 1,544 for enlisted. There are 45 pads for privately-owned trailers in the Mobile Home Park.

The location is very convenient to the amenities of the Community Area. The base exchange, commissary, chapel, housing office, youth center, child development center, and hospital are located off Vermont Garrison Street, which separates the Family Housing Area from the Community Area.

The theater, bowling alley, convenience stores, and athletic fields are located just a few blocks away from Vermont Garrison Street. The golf course separates the housing from the industrial area and the flight line.

4-7A Family Housing

4-7B Well-kept landscaping enhances neighborhood quality.

4-7C Sidewalks, street trees, and consistent building setbacks improve the streetscape in the Family Housing Area.

FAMILY HOUSING

Architectural Compatibility Standards - Seymour Johnson AFB, NC 4-8

4.6.0 Summary of Design Guidelines for

the Family Housing Area (Non-Housing Facilities)

4.6.1 All non-housing facilities built within this

zone must follow the guidelines for construction within the Community Area (refer to page 4-3).

4.7.0 Summary of Design Guidelines for

the Family Housing Area (Housing Units)

4.7.1 Site Planning:

• Site new housing with consistent front yard setbacks.

• Provide off-street parking for at least two cars per unit (Figure 4-8A).

• Locate parks and play facilities within a five minute walk of every house (Figure 4-8B).

• Develop safe pedestrian circulation systems.

4.7.2 Building Form:

• Gabled or hipped roof building forms that suggest the appearance of upscale private sector housing developments.

4.7.3 Roofs:

• Asphalt shingles with minimum 30-year warranty. Minimum 3:12 pitch.

4.7.4 Exterior Walls:

• Red brick to match existing renovated housing units.

4.7.5 Doors and Windows:

• Prefinished aluminum or vinyl windows with high performance insulated glazing and thermal break. Steel doors shall be used at entrances and garage doors.

4.7.6 Colors:

• Refer to the Seymour Johnson AFB Housing Community Plan for color schemes.

4-8A Provide off-street parking for at least two cars per unit.

4-8B Neighborhood playgrounds should be conveniently located in family housing.

Architectural Compatibility Standards - Seymour Johnson AFB, NC 5-1

5.0.0 Architectural

5.1.0 General

5.1.1 Design Criteria

Facility design shall comply with the most current edition of

• Military Handbook 1008C Fire Protection for Facilities Engineering, Design and Construction.

• Uniform Building Codes (UBC) and the North Carolina State Building Code. The most stringent requirements shall apply.

• The Americans with Disabilities Act (ADA) and the Uniform Federal Accessibility Standards (UFAS). The most stringent requirements shall apply.

• Force Protection Anti-Terrorism measures.

• Criteria as referenced by the Scope of Work document or otherwise applicable to the project.

5.1.2 Architectural Review

• Each facility design project will include an architectural review by the Base Civil Engineer as part of the 35% Preliminary Design Submittal review process.

• The cover letter accompanying the submittal must identify any items that do not comply with the Seymour Johnson Architectural Compatibility Standards and the ACC Architectural and Interior Design Standards.

• Self-help Projects: Designers of self-help projects should schedule a meeting with Base Civil Engineering to discuss requirements prior to the start of a project. Refer to Section 9.0 for additional information.

5.1.3 Additions

• In conformance with ACC policy, when the floor area of an addition is less than 25% of the existing building floor area, the addition should be designed to match the existing building, unless otherwise instructed by the Base Civil Engineer.

• Where a high maintenance existing finish such as paint occurs, provide a low maintenance, integrally colored material in compliance with the Architectural Compatibility Standards.

• When the floor area of the addition is equal to 25% or more of the existing building floor area, the addition and the original building are required to comply with the Architectural Compatibility Standards.

• Whether large or small, additions should not appear as obvious add-ons. Match form, massing and scale to make the addition and the original structures appear as parts of a new, unified whole.

Architectural Compatibility Standards - Seymour Johnson AFB, NC 5-2

5.2.0 Site Planning

5.2.1 Land Use

• All site planning shall be in conformance with the Seymour Johnson AFB General Plan.

5.2.2 Site Development Pattern

• Arrange buildings in tight groupings, which share parking and encourage people to walk between buildings (Figure 5-2A).

• Where possible, integrate new buildings into existing groupings.

• Areas between buildings should be designed as exterior pedestrian spaces.

• Use building forms, landscaping, and existing topography to enclose outdoor spaces.

• Configure site to separate service zones from parking and pedestrian spaces. Screen service areas from major streets.

5.2.3 Environmental Stewardship

• Site planning shall minimize the negative impact on the natural environment.

• Design facilities to work within the existing topography; preserve as many desirable trees as possible.

• In undeveloped forest areas, configure the site layout to retain large parcels of wooded habitat by clustering development.

5.2.4 Future Development

• Where the possibility of facility expansion exists, the building site plan should show the proposed method of expansion (addition or separate building).

• Coordinate location of underground utilities, parking and service areas to minimize impact on future growth.

5.2.5 Location of Visually Objectionable Items

• Above ground utility equipment, transformers, meters, connections, trash receptacles, etc. shall be discreetly located at the rear of the site and shall be screened with walls and landscaping.

No such items shall be visible from the main entry or the principal viewing street.

5-2A Tight grouping of buildings encourages pedestrian circulation.

Architectural Compatibility Standards - Seymour Johnson AFB, NC 5-3

5.3.0 Building Form

• Use of simple massing and sloped roof forms is recommended (Refer to 5.4.A Roofs).

• Maximum height for all buildings except dormitories, is two stories. Dormitories may be three stories.

• Arrange building forms to create outdoor pedestrian spaces where possible.

5.3.1 Industrial Buildings

• Use simple functional forms for industrial buildings.

• Incorporate smaller additive forms to give human scale to large building masses (Figures 5-3A and 5-3B).

5-3A Use additive forms to reduce scale of large building masses.

5-3B One-story addition constructed of split-face concrete masonry adds human scale and helps to integrate the building with surrounding facilities.

Architectural Compatibility Standards - Seymour Johnson AFB, NC 5-4

5.4.0 Roofs

5.4.1 Form

• One roof form should generally be used throughout a building (Figure 5-4B).

• Examples of basic roof forms are shown in Figure 5-4A.

5.4.2 Slope

• Minimum roof slope should be 3:12. Refer to guidelines for each visual area for specific requirements.

• Exception: Very large buildings and hangars may have slopes as low as 1:12 with the approval of the Base Civil Engineer and ACC Command Architect.

• The roof slope should be consistent throughout a building. This includes canopies, porches, and other roofed elements.

5.4.3 Roof Material

• Roofs shall be dark bronze standing seam metal.

Color shall match Petersen Aluminum Corporation (PAC-CLAD) “Dark bronze.”

Exception: For energy efficiency, color of metal roof for large buildings may be beige, Fed. Std. 595b #23617, with approval of the Base Civil Engineer.

Exception: In cases where it is neither practical nor affordable to install metal roofs, a built-up roof system may be used with the approval of the BCE and ACC Command Architect.

Exception: Asphalt shingles with minimum 3:12 pitch shall be used for Family Housing.

• Roofs shall have a minimum insulation value of R-19.

5.4.4 Roof Warranties

Roof material, finish and workmanship shall be fully warranted for the following time periods:

• Metal roof: Fluoropolymer (e.g. Kynar 500) factory finish, 20 years.

• Fiberglass Reinforced Asphalt Shingles: 30 years.

5-4A Basic roof types.

5-4B Hipped roof forms of the Housing Office

Architectural Compatibility Standards - Seymour Johnson AFB, NC 5-5

5.4.5 Gutters and Downspouts

• Gutters may be exposed or integrated into the fascia design.

• Downspouts may be exposed or concealed within exterior walls (Figure 5-5A). Exposed downspouts shall be factory finished to match adjacent wall or metal roof and trim color.

• Rain diverters or gutters and downspouts must be provided over building entrances.

• In wooded areas, take maintenance into consideration when designing roof drainage.

• If possible, downspouts should be inserted into cast iron boots and routed into the underground storm drainage system. As an alternative, provide concrete splash blocks at grade. Locate splash blocks to avoid conflict with pedestrian walks.

5.4.6 Rooftop Equipment

• Equipment shall not be mounted on the roof.

• Exception for Existing Flat Roofs: Rooftop equipment may be used on flat (low-slope) roofs only if alternate locations for equipment are economically prohibitive. When rooftop equipment is used, it must be placed out of view on all sides of the building, or factory-painted in a color scheme approved by the Base Civil Engineer. Equipment should be screened if it is not feasible to place the equipment out of view.

Screened equipment does not require painting.

Use of rooftop equipment requires Base Civil Engineer approval.

• All roof penetrations and flashings that are exposed to view shall be factory finished to match the roof color. Any elements exposed to view that cannot be factory finished (for example: plumbing vents through roof) shall be field painted to match the roof color.

• Minimize roof penetrations. Locate penetrations on the least visually objectionable side of the roof. Strategically locate roof penetrations so they create a visually attractive pattern on the roof.

5-5A Concealed downspouts on dormitories.

Architectural Compatibility Standards - Seymour Johnson AFB, NC 5-6

5.5.0 Entrances

5.5.1 Visibility

• At least one building entrance must be clearly visible from the main viewing street and the parking area (Figure 5-6A).

• Each building entrance must be readily identifiable (Figure 5-6B).

5.5.2 Entry Sequence

• Facility design should address the entire entry sequence beginning with vehicular/pedestrian circulation routes and terminating in the building lobby.

• Where a front (street) and a back (parking) entrance is required, both entrances should share a common lobby.

5.5.3 Protective Cover

• All exterior entrance doors must have at least 3’-0” of protective cover.

• Roof overhangs, recesses, colonnades or other integrated elements may be used.

• Separate elements applied to the exterior walls (example: cantilevered or bracketed canopies or glass roofed vestibules) are discouraged.

5-6A 4th Fighter Wing Headquarters

5-6B Porches create easily identifiable entrances to housing units.

5-6C Front porch defines entry to Distinguished

Visitor’s Quarters

Architectural Compatibility Standards - Seymour Johnson AFB, NC 5-7

5.6.0 Fascias and Soffits

5.6.1 Fascia and Trim

• Fascia material shall be metal, factory finished to match metal roof color.

• Exception: Refer to the Seymour Johnson Housing Community Plan for color of fascia and trim on family housing units.

5.6.2 Soffits

• Soffit material should be factory finished metal or Portland cement plaster. Color may be off-white or may match metal roof color.

• An alternate soffit material and color may be used with the prior approval of the Base Civil Engineer.

• Soffit design should incorporate ventilation for roof/attic spaces. Soffit vents should be used in conjunction with ridge vents or louvers (Figure 5-7A).

• Consider use of deep soffits or roof overhangs to shade exterior walls and windows during summer months (Figure 5-7B).

5-7A Use soffit vents, ridge vents or louvers to ventilate the roof and attic spaces.

5-7B Deep soffits and balconies provide shade at dormitories.

Architectural Compatibility Standards - Seymour Johnson AFB, NC 5-8

5.7.0 Exterior Walls

5.7.1 Materials

• In the Community Area and the Family Housing Area, the primary wall material shall be modular red brick with off-white mortar (Figure 5-8A). Brick shall match Pine Hall Old Colony/Light Range modular face brick.

• In the Mission/Industrial Area, the primary wall material shall be integrally colored and textured concrete masonry units. Color of masonry units and mortar shall match Adams A815W, “Ivory,” as used on the F-15E Simulator building and Fighter Squadron Operations building (Figure 5-8B). The primary CMU texture shall be split-face. Other textures may be used as accents.

Exception: Prefinished metal wall panels may be used on large industrial/hangar buildings in the Mission/Industrial Area.

• The following requirements apply to use of metal wall panels:

• Prior approval of HQ Air Combat Command. Approval request must be submitted during programming phase. Refer to ACC Architectural and Interior Design Standards for further information (see Appendix).

• Building shall have a split-face concrete masonry unit base. Height of base shall be proportional to building size, but no less than four feet in height. CMU and mortar colors shall match Adams A815W “Ivory.”

• Panels shall be factory finished. 20-year full replacement warranty shall be provided.

Color shall be Fed. Std. 595b #23617.

5.7.2 Detailing

• Masonry detailing is encouraged in lieu of applied ornamentation. For example: soldier courses, stacked bond, special sill and watertable shapes, reveals, etc.

• Cast stone may be used as accents on brick or concrete masonry buildings.

5-8A Red brick on Housing Office

5-8B Integrally colored and textured concrete masonry units on Fighter Squadron Operations building

Architectural Compatibility Standards - Seymour Johnson AFB, NC 5-9

5.7.3 Wall Construction

• Wall insulation shall be a minimum of R-11.

• Wall louvers: Exterior metal louvers shall be stormproof and able to withstand wind-driven rain without infiltration. Obtain minimum design wind speed from the North Carolina State Building Code. (90 mph) Louvers shall have fluoropolymer (e.g. Kynar 500) coating to match adjacent wall color.

Architectural Compatibility Standards - Seymour Johnson AFB, NC 5-10

5.8.0 Windows and Doors

5.8.1 Design

• Design building fenestration for user comfort and energy efficiency. Reduction of cooling loads is critical during Seymour Johnson’s hot summer months.

• Provide operable windows in all occupied spaces. Specify insect screens and accessible hardware (Figure 5-10A).

• Orient windows to take advantage of cross ventilation.

• Incorporate overhangs, porches, colonnades, high performance glazing and other strategies to block direct summer solar gain (Figure 5-10B).

• Use north facing clerestory windows and other natural lighting methods to reduce lighting demand and associated cooling loads.

5.8.2 Materials

• Windows shall have aluminum, thermal-break frames. Finish shall be dark bronze anodized or fluoropolymer coating (e.g. Kynar 500) in color to match Petersen Aluminum Corporation (PAC-CLAD) “Dark bronze.”

• Glass shall be insulated, solar bronze tint, with minimum reflectance. Due to summer cooling loads, consider high-performance, low-emmissivity, glazing where feasible.

Exception: Family housing may use aluminum or clad or vinyl windows, color white. Glass in housing should be clear or have minimal tint.

• Primary Entrances: Aluminum storefront will be used at primary entrances. Color should be dark bronze anodized or fluoropolymer finish (e.g.

Kynar 500) matching Petersen Aluminum Cororation (PAC-CLAD) “Dark bronze.”

Exception: Family housing should use galvanized, insulated residential steel entrance doors that have been properly prepared, primed, and finished at the factory.

• Garage doors in family housing should be galvanized steel that have been properly prepared, primed, and finished at the factory.

5-10A Operable windows improve user comfort.

5-10B Colonnades and overhangs shade building exterior and reduce cooling loads.

Architectural Compatibility Standards - Seymour Johnson AFB, NC 5-11

5.8.2 Materials (continued)

• Secondary Exterior Doors and Frames: Specify steel doors and frames on all facilities. Hollow metal doors and frames should be galvanized and field painted to match metal roof color.

5.8.3 Finish Hardware

• Locks shall be equal to and compatible with the base standard interchangeable core system manufactured by Best Lock Co.

• Provide a 3-year warranty on parts and labor for all locks.

• Prior to the Final Design Submittal, project designer shall discuss keying requirements with the building user.

5.9.0 Smoking Areas

• Designated smoking areas shall be located away from entrances, exits, and any air intake system for a facility. Smoking areas shall be signed and located in accordance with AFI 40- 102.

• Smoking areas for Federal Prison inmates shall be separate from the smoking areas for Squadron personnel.

SITE DESIGN

Architectural Compatibility Standards – Seymour Johnson AFB NC 6-1

6.0.0 Site Design

6.1.0 Vehicular Circulation

• Develop streetscapes by providing street lighting, sidewalks, and street trees (Figure 6-1A).

• Provide curb and gutter at all new pavement.

• Separate vehicular and pedestrian circulation.

• Incorporate bikeways.

• Locate utilities underground where feasible (Figures 6-1B and 6-1C).

• Minimize curb cuts.

• Provide maintenance vehicle access to building mechanical rooms where feasible. Pavement or reinforced sidewalks are acceptable for vehicle access.

• Site design shall conform to the requirements of ADA/UFAS. The most stringent requirements shall apply.

• Project designers shall coordinate Force Protection Anti-Terrorism requirements with the Base Civil Engineer.

6-1A Street lighting and sidewalks improve safety and appearance.

6-1B Streetscape before improvements

6-1C Streetscape improved with underground utilities, sidewalks, lighting, and street trees.

Architectural Compatibility Standards – Seymour Johnson AFB NC 6-2

6.2.0 Parking

Design parking areas to provide a safe, functional layout and reduce the visual impact of parked cars.

6.2.1 Siting

• Site parking areas around the perimeter of building groups.

• Do not locate parking between a building and the main viewing street (Figure 6-2A).

• Do not let parking occupy pedestrian spaces between buildings in a group.

6.2.2 Screening

• Use buildings, natural topography and landscaping to screen parking from the primary street (Figure 6-2B).

• Subdivide large parking areas into lots of 50 cars or less, where feasible. Small parking areas reduce the negative visual impact and allow opportunity for additional landscaping.

• When developing parking areas, try to save as many desirable existing trees and shrubs as possible.

• Eliminate on-street parking where possible.

6.2.3 Pedestrian Paths

• Provide safe pedestrian paths from parking to building entrances.

• Provide handicap accessible parking spaces and accessible routes to the building in conformance with ADA/UFAS.

6.2.4 Services

• Separate service/dumpster locations from pedestrian circulation. Ensure turnaround space for fire trucks and service vehicles.

6-2A Example of good site planning.

6-2B Landscape screening between street and parking area.

Architectural Compatibility Standards – Seymour Johnson AFB NC 6-3

6.3.0 Pedestrian Circulation

6.3.1 Paths

• Provide safe, convenient paths to encourage bicycle and pedestrian circulation (Figure 6- 3A).

• Design continuous paths linking buildings, courtyards, parks, and other activity nodes.

• Provide bike paths with the roadway or create separate bike path/jogging trails.

• Separate vehicular and pedestrian circulation (Figure 6-3B).

6.3.2 Sidewalks

• Add sidewalks to existing roadways where possible. New roads in developed areas should have sidewalks on both sides of the road.

• Set sidewalks back an appropriate distance from the curb edge to allow for landscaping and maintenance.

6.3.3 Landscaping

• Promote security: Configure paths and design landscaping to permit surveillance of pedestrian circulation routes (Figure 6-3C).

• Provide shade trees along paths.

• Provide low-maintenance, vandal resistant seating and water fountains at intervals along paths.

6-3A Well-lit paths encourage pedestrian circulation.

6-3B Jogging trail is well shaded by trees.

6-3C Passive surveillance of paths increases pedestrian safety.

Architectural Compatibility Standards – Seymour Johnson AFB NC 6-4

6.4.0 Site Lighting

6.4.1 Design

• Create a unified appearance on base by selecting light fixtures of a consistent design and lamp type.

• Fixtures shall be low maintenance and vandal resistant.

• Parking lot and area lighting shall be high pressure sodium, rectangular cut-off (shoebox) fixtures. Poles shall be square, straight aluminum shaft. Color shall be dark bronze anodized finish (Figure 6-4A).

• Street lights shall be high pressure sodium cobrahead fixtures mounted on 25’ tall poles with a single 8’ long arm. Poles shall be clear anodized, round tapered seamless aluminum (Figure 6-4B).

• Fixtures for pedestrian circulation and area lighting shall be mounted on 12’ to 15’ high posts (Figure 6-4C). Color shall be dark bronze anodized.

• Lighting shall be designed to withstand minimum 100 mph wind speed (if code requirements differ, the more stringent requirement shall apply).

• Use architectural lighting of landmark buildings to aid way-finding and accentuate important structures. Coordinate proposed lighting scheme with Base Civil Engineering.

6-4A Fixture for parking lot and area lighting.

6-4B Cobrahead street lights.

6-4C Pedestrian path lighting

Architectural Compatibility Standards – Seymour Johnson AFB NC 6-5

6.5.0 Fences and Screens

6.5.1 Screening

• Provide screening around mechanical equipment, storage areas, trash dumpsters and other visually objectionable items.

• Mechanical equipment shall be screened with landscape materials, metal screen enclosure, metal panel privacy fence, or masonry screen walls. Color of metal screens and metal panel privacy fencing shall match Rohn “Canyon Brown.” Finish shall have 20-year warranty.

Masonry shall match material of the adjacent building (Figure 6-5A).

• Equipment screens shall allow required clearance for equipment maintenance, removal, and airflow. Provide vehicle access to mechanical equipment areas where necessary.

Pavement or reinforced sidewalks are acceptable for vehicle access.

• Dumpsters shall be screened with 3-sided masonry enclosures (Figure 6-5B). Minimum height of walls shall be 6” greater than dumpster height. Provide concrete slab and 6” diameter concrete filled pipe bollards to prevent damage to walls.

• Gas service pressure reducing stations shall be installed in close proximity to an existing or new building. Stations shall be screened appropriately.

6.5.2 Fences

• Use masonry walls or metal panel privacy fences to screen storage areas (Figure 6-5C).

Metal fence shall have factory finish with 20-year warranty. Color shall match Rohn “Canyon Brown.”