B200_Energy_100__Dwg_Set.pdf
PDF 3 MB Posted
- Attached to
- Bldg 200 HVAC Renovation Federal contract opportunity
- Solicitation number
- FA4497-15-R-0004
About this file
B200 Energy 100 Dwg Set
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Questions_ _Answers__2_HVAC_Renovation _B200.pdf | ||
| SOW_Attachment_2_-_B200_Energy_Upgrades_Specifications.pdf | ||
| UFGS_01_45_00.00_10_Quality_Control.pdf | ||
| 09_51_00___Acoustical_Ceiling_Tile_Specs.pdf | ||
| Questions_ _Answers_HVAC_Renovation _B200.pdf | ||
| FA4497-15-R-0004-0002_Amendment_to_Extend_RFP_Due_Date.pdf | ||
| SOW_Attachment_2_-_B200_Energy_Upgrades_Specifications.pdf | ||
| 01_11_10_DAFB_General_Requirements_(1_MAY_14).doc | DOC document | |
| 02_61_10_DAFB_Environmental_Specifications_(1_MAY_14).doc | DOC document | |
| JAG_Office_200_HVAC_SOW__(05-15-15).pdf | ||
| FA4497-15-R-0004_RFP_Bldg_200_HVAC_Reno.pdf | ||
| 01_14_10_DAFB_Site_Management_(1_MAY_14).doc | DOC document | |
| 31_25_10_DAFB_Sediment_and_Erosion_Control_(1_MAY_14).doc | DOC document | |
| Davis-Bacon_WD_DE150004.pdf | ||
| FA4497-15-R-0004-0001___Amendment_to_B200_HVAC_Reno_RFP.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UPUP
1. EXTERIOR DOORS: REMOVE SEALANT AND CLEAN FRAME. REMOVE
EXISTING WEATHERSTRIPPING AND SWEEP. INSTALL NEW
WEATHERSTIPPING AND SWEEP. SEAL INTERIOR AND EXTERIOR OF
FRAMES.
2. AT ALUMINUM ENTRANCES, INSTALL NEW PILE WEATHERSTRIPPING.
USE PILE OF SUFFICIENT WIDTH AND LENGTH TO COMPLETELY SEAL
OPENING BETWEEN DOORS AND/OR BETWEEN DOOR AND FRAME.
NO LIGHT SHALL PENETRATE THROUGH JOINT.
3. VESTIBULE: REMOVE GLAZING AND RESET IN EXISTING FRAME WITH
NEW CONTINUOUS WEDGE SEAL AND GASKET.
4. VESTIBULE: REMOVE SEALANT AT VERTICAL JOINTS BETWEEN
FRAME AND MASONRY, AT CORNER MULLIONS, AND AT HORIZONTAL
JOINTS BETWEEN FRAME AND CONCRETE SILL. REMOVE SEALANT
CLEAN FRAMES AND RESEAL.
5. SAW CUT AND GRIND CONCRETE SMOOTH TO CREAT A SLOPED SILL
WITH SLOPE NO LESS THAN 1 INCH IN 12.
6. REMOVE VCT AND STRIP ADHESIVE. GRIND CONCRETE SLAB TO
LEVEL 3 POLISH WITH 800 GRIT DIAMOND ABRASIVE
7. NEW WALK OFF MATT (BY OWNER).
8. EXTERIOR WINDOWS: REMOVE EXISTING SEALANT. CLEAN
WINDOWS, REMOVE EFFLORESCENTS AND CHALKING. RESEAL
PERIMETER OF WINDOW.
9. EXTERIOR WINDOWS: CLEAN MORTAR JOINT AND REPOINT.
10. REMOVE EXISTING MECHANICAL LOUVER. INFILL OPENING WITH CMU
AND BRICK TO MATCH EXISTING CONSTRUCTION.
11. REMOVE WINDOWS, CMU AND BRICK VENEER TO PROVIDE
OPENING FOR MECHANICAL W`ORK, APPROX. 10'W X 10'H.
COORDINATE WITH MECHANICAL CONTRACTOR. BRACE
EXISTING STRUCTURE AS NECESSARY TO TEMPORARILY SUPPORT.
REBUILD WALL: CLEAN AND REUSE EXISTING BRICK, MIXING NEW
BRICK IN AS NECESSARY. TEETH BRICK INTO EXISTING.
SEE DETAIL 5/A2.1
12. PATCH EXISTING BUILT UP ROOF TO MATCH. NEW MECHANICAL
HOOD AND CURB TO BE INSTALLED BY MECHANICAL CONTRACTOR.
REMOVE EXISTING CURBS.
13. REMOVE EXISTING CEILING GRID AND TILE AS NECESSARY TO ACCESS
MECHANICAL WORK. SEE MECHANICAL DWGS AND COORDINATE WITH
MECHANICAL CONTRACTOR FOR SPECIFIC AREA AND SCOPE. SAVE
TILE TO REUSE; REINSTALL WHEN MECHANICAL WORK COMPLETED.
REPLACE DAMAGED TILE FROM EXISTING CEILING DESIGNATED BY
OWNER. REPLACE BORROWED TILES WITH NEW TO MATCH EXISTING.
FLOOR PLAN NOTES
SEE NOTE 1 & 2
SEE NOTE 4
SEE NOTES 8 & 9 (TYP.)
SEE NOTES 8 & 9 (TYP.)
SEE NOTE 5
SEE NOTE 6
SEE NOTE 7
SEE NOTE 4
SEE NOTE 10
SEE NOTE 1 & 2
SEE NOTE 2
SEE NOTE 1 & 2
SEE NOTE 6
SEE NOTE 1
SEE NOTE 11
SEE NOTES 13.
SEE NOTES 8 & 9
(TYP.)
SEE NOTES 8 & 9
(TYP.)
SEE NOTE 12
SEE NOTE 13
EXISTING ALUMINUM STOREFRONT
10°
SAW CUT EXISTING CONCRETE
TO PROVIDE POSITIVE DRAINAGE
REMOVE EXISTING SEALANT AND CLEAN
INSTALL NEW BACKERROD AND RESEAL
SEALANT
REMOVE VCT
GRIND AND POLISHED CONCRETE
W-5134
SHT. OF
DESIGNED BY:DRAWN BY:SCALE:PROJECT #:DATE:
APPROVEDAPPROVEDSUBMITTED
COMMANDERCHIEF ENGINEERCHIEF ENGINEER
AS NOTED
BLDG. 200 ENERGY UPGRADES AT DOVER AFB, DE
AIR MOBILITY COMMAND
DOVER AIR FORCE BASE, DELAWARE
DESCRIPTIONDATEREV
M D A
6100% DESIGN
ISSUED FOR 95% REVIEW
DRAWN APPR'D
31AUG12 RGC GRR
G. CAMPBELL G. RICHTERS
ISSUED FOR INSTALLATION12APR13 RGC GRR
A1.1
FLOOR PLANS
BLDG. 200
04/12/2013
1/8" = 1'-0"A1.1
1 FIRST FLOOR PLAN
1/8" = 1'-0"A1.1
2 SECOND FLOOR PLAN
3" = 1'-0"A1.1
3 STOREFRONT DETAIL
SEE NOTE 5
SEE NOTE 8
SEE NOTE 9
SEE NOTE 3 (TYP)
SEE NOTE 4
SEE NOTE 1 & 2
SEE NOTE 8
SEE NOTE 9
SEE NOTE 8
SEE NOTE 9
SEE NOTE 4
SEE NOTE 10
SEE NOTE 3 (TYP)
SEE NOTE 11
SEE NOTE 1 & 2
SEE NOTE 8
SEE NOTE 9
SEE NOTE 1 & 2
SEE NOTE 8
SEE NOTE 9
1. EXTERIOR DOORS: REMOVE SEALANT AND CLEAN FRAME. REMOVE
EXISTING WEATHERSTRIPPING AND SWEEP. INSTALL NEW
WEATHERSTIPPING AND SWEEP. SEAL INTERIOR AND EXTERIOR OF
FRAMES.
2. AT ALUMINUM ENTRANCES, INSTALL NEW PILE WEATHERSTRIPPING.
USE PILE OF SUFFICIENT WIDTH AND LENGTH TO COMPLETELY SEAL
OPENING BETWEEN DOORS AND/OR BETWEEN DOOR AND FRAME. NO
LIGHT SHALL PENETRATE THROUGH JOINT.
3. VESTIBULE: REMOVE GLAZING AND RESET IN EXISTING FRAME WITH
NEW CONTINUOUS WEDGE SEAL AND GASKET.
4. VESTIBULE: REMOVE SEALANT BETWEEN FRAME AND MASONRY AT
VERTICAL AND HORIZONTALS. CLEAN FRAMES AND RESEAL.
5. SAW CUT AND GRIND CONCRETE SMOOTH TO CREAT A SLOPED SILL
WITH SLOPE NO LESS THAN 1 INCH IN 12.
6. REMOVE VCT AND STRIP ADHESIVE. GRIND AND POLISH CONCRETE
SLAB SMOOTH TO LEVEL 3 POLISH WITH 800 GRIT DIAMOND ABRASIVE.
7. NEW WALK OFF MATT (BY OWNER).
8. EXTERIOR WINDOWS: CLEAN WINDOWS, REMOVE EFFLORESCENTS AND
CHALKING.
9. EXTERIOR WINDOWS: CLEAN MORTAR JOINT AND REPOINT.
10. REMOVE EXISTING MECHANICAL LOUVER. INFILL OPENING WITH CMU
AND BRICK TO MATCH EXISTING CONSTRUCTION.
11. REMOVE WINDOWS, CMU AND BRICK VENEER TO PROVIDE OPENING
FOR MECHANICAL WORK, APPROX. 10'W X 10'H. COORDINATE WITH
MECHANICAL CONTRACTOR. BRACE EXISTING STRUCTURE AS
NECESSARY TO TEMPORARILY SUPPORT. REBUILD WALL: CLEAN AND
REUSE EXISTING BRICK, MIXING NEW BRICK IN AS NECESSARY. TEETH
BRICK INTO EXISTING. SEE DETAIL 5/A2.1.
12. PATCH EXISTING BUILT UP ROOF TO MATCH. NEW MECHANICAL HOOD
AND CURB TO BE INSTALLED BY MECHANICAL CONTRACTOR. REMOVE
EXISTING CURBS.
FLOOR PLAN NOTES
ADJUSTABLE BRICK TIES @ 16" O.C.
VERTICAL, @ 16" O.C. HORIZONTAL
4" BRICK VENEER TO
MATCH EXIST.
8" CMU
6 GA. LADDER HORIZ.
REINFORCEMENT @
16" O.C. VERTICAL
FIELD VERIFY
W-5134
SHT. OF
DESIGNED BY:DRAWN BY:SCALE:PROJECT #:DATE:
APPROVEDAPPROVEDSUBMITTED
COMMANDERCHIEF ENGINEERCHIEF ENGINEER
AS NOTED
BLDG. 200 ENERGY UPGRADES AT DOVER AFB, DE
AIR MOBILITY COMMAND
DOVER AIR FORCE BASE, DELAWARE
DESCRIPTIONDATEREV
M D A
6100% DESIGN
ISSUED FOR 95% REVIEW
DRAWN APPR'D
31AUG12 RGC GRR
G. CAMPBELL G. RICHTERS
ISSUED FOR INSTALLATION12APR13 RGC GRR
A2.1
EXTERIOR
ELEVATIONS
BLDG. 200
04/12/2013
1/8" = 1'-0"A2.1
1 NORTH ELEVATION
1/8" = 1'-0"A2.1
2 SOUTH ELEVATION
1/8" = 1'-0"A2.1
3 WEST ELEVATION
1/8" = 1'-0"A2.1
4 EAST ELEVATION
1 1/2" = 1'-0"A2.1
5 TYP. WALL SECTION
| G-1.1 |
| A-1.1 |
| A-2.1 |
| P-1.1 |
| M-1.1 |
| M-1.2 |
| M-1.3 |
| M-1.4 |
| M-1.5 |
| M-2.1 |
| M-2.2 |
| M-3.1 |
| M-3.2 |
| M-4.1 |
| E-1.1 |
| E-2.1 |
| E-3.1 |
File details come from the government source that posted it. Updated .