This document includes a roof plan drawing and specifications for repairing the roof at Building B160 on Columbus Air Force Base, along with the corresponding federal contract opportunity solicitation. The roof plan drawing depicts the layout of the roof and identifies various roof features such as a chiller, skylights, and other penetrations. The specifications provide requirements for roofing materials and components, including an EPDM membrane, insulation substrate, pourable sealer, and EcoWhite and QuickSeam flashings. The federal contract opportunity is solicited by the Department of the Air Force Air Education and Training Command to repair the BX Roof at Building B160 in accordance with the roof plan and specifications. The repair work includes removing all existing flashings and leads, installing new roofing materials, and fabricating penetration pockets with PVC pipes as depicted in the roof plan.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Overall Roof
October 21, 2019 50 100 200 fl polylinelayer
-- Override 1 0 15 30 60 m
Installation Boundary
Roof Replacement Within This Box
Red = Building Outline
1390999310C Rectangle
1390999310C Line
1390999310C Line
1390999310C Line
1390999310C Line
1390999310C Typewritten Text Chiller
1390999310C Typewritten Text Satellite Dish
1390999310C Line
1390999310C Typewritten Text Skylight
1390999310C Typewritten Text Items not labeled must be identified by Contractor Field Surveys.
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box
1390999310C Text Box Boundary of Area of Work
1390999310C Pencil
Platinum
Year
FIRESTONE INSULATION
SUBSTRATE
CUT PVC PIPE (SEE NOTES)
ECOWHITE 12" QUICKSEAM FLASHING
NOTES:
1.
FIRESTONE POURABLE SEALER MOUNDED TO SHED WATER.3.
CUT PVC PIPE MINIMUM 2" (50.8 mm) HIGH AND OF SUFFICIENT5.
WIDTH TO ALLOW 1" (25.4 mm) OF SPACE BETWEEN PENETRATIONS
AND BETWEEN THE PVC SHELL AND PENETRATIONS. MEMBRANE
MUST EXTEND TO WITHIN 1/2" (12.7 mm) OF PENETRATION.
IF FIELD MEMBRANE IS CUT FOR INSTALLATION, THE6.
MEMBRANE MUST BE REPAIRED WITH .090 EPDM
PRIOR TO INSTALLATION OF POURABLE SEALER POCKET.
PE
NE
TR
AT
IO
N
FIRESTONE INSULATION
SUBSTRATE
PE
NE
TR
AT
IO
N
BONDING ADHESIVE
NO
N-
SH
RI
NK
IN
G
GR
OU
T
(MINIMUM DEPTH OF 2" (50.8 mm), REMAINDER OF POCKET
MAY BE FILLED WITH A NON - SHRINKING GROUT).
FIRESTONE POURABLE SEALER
7. APPLY ECOWHITE LAP SEALANT AROUND ENTIRE PERIMETER
OF FLASHING. REFER TO P-EW-LS-4 FOR SEAM EDGE TREATMENT.
8. SINGLE-PLY QUICKPRIME REQUIRED ON PENETRATIONS AND
MEMBRANE INSIDE OF PENETRATION POCKET.
ISSUE / REVISION
DATE:
NOT TO SCALEACCEPTABLE SYSTEMS:
DETAIL NO.
BUILDING PRODUCTS
NOBODY COVERS YOU BETTER.
www.firestonebpco.com
TM
MAXIMUM WARRANTY: 30 YEARS
PENETRATION WITH FIELD FABRICATED ROUND
PVC PENETRATION POCKET
PLATINUM
2/1/2010
REFER TO FIRESTONE WEBSITE FOR MOST CURRENT
INFORMATION.
CONTINUOUS BEAD OF
ECOWHITE LAP SEALANT
1" (25.4 mm) MIN.
SINGLE-PLY QUICKPRIME (SEE NOTES)
EPDM MEMBRANE
REMOVE ALL EXISTING FLASHINGS, LEADS, ETC.2.
PIPE SURFACE MUST BE FREE OF ALL RUST, GREASE
INSULATION, ETC.
9. DO NOT USE WHEN SERVICE LINE TEMP. EXCEEDS 180°F.
REFER TO P-EW-P-4.
4. DO NOT USE OVER EXISTING PENETRATION POCKETS.
.090" ECOWHITE PLATINUMECOWHITE 6" (OR 5" BLACK)
QUICKSEAM FLASHING
http://www.firestonebpco.com