Report_3_Bridge_Inspection_Little_Swan.pdf

PDF 4 MB Posted

Attached to
Natchez Trace Parkway 1E10 Federal contract opportunity
Solicitation number
DTFH71-15-B-00005
Issued by
Department of Transportation Federal Highway Administration

About this file

Report 3_Bridge Inspection_Little Swan

View the file

Other files for this federal contract opportunity

Other files attached to Natchez Trace Parkway 1E10, newest first.
File Type Posted
Amendment_0006_-_PRA-NATR_1E10.pdf PDF
Amendment_0005-_PRA-NATR_1E10.pdf PDF
Amendment_0004_-_PRA-NATR_1E10.pdf PDF
Amendment_0003_-_PRA-NATR_1E10.pdf PDF
Amendment_0002-_PRA-NATR_1E10.pdf PDF
Amendment_0001_-_PRA-NATR_1E10.pdf PDF
Report_5_Soils_and_Foundation.pdf PDF
Report_4_Bridge_Inspection_Big_Swan.pdf PDF
Report_2_NEPA_Big_Swan.pdf PDF
FP03_Eng_.pdf PDF
Plans_PRA-NATR_1E10.pdf PDF
IFB_Solicitation_Book_-_PRA-NATR_1E10.pdf PDF
Report_6_Certification_Program_for_Bridge_Temporary_Works.pdf PDF
Report_1_NEPA_Little_Swan.pdf PDF
ADV_Subcontracting_Plan.doc DOC document
FP03_Errata.pdf PDF
ADV_Bidder's_Qualifications_Form.doc DOC document
VETS-100A-Form.pdf PDF
Synopsis_PRA-NATR_1E10.doc DOC document
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BRIDGE INSPECTION REPORT

LITTLE SWAN CREEK BRIDGE

NATCHEZ TRACE PARKWAY OVER LITTLE SWAN CREEK

NATCHEZ TRACE PARKWAY

LN

STRUCTURE NO. 5570-004P

INSPECTION TYPE: ROUTINE

INSPECTION DATE: 3/14/13

Report prepared by: WD

MILE POINT: 386.89

Federal Highway Administration KILOMETER POINT: 622.62 Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 http://www.efl.fhwa.dot.gov/FLHBO/BIP http://www.efl.fhwa.dot.gov/FLHBO/BIP

STRUCTURE SUMMARY STRUCTURE NO. 5570-004P

LITTLE SWAN CREEK BRIDGE INSPECTION DATE: 3/14/13

BRIDGE IDENTIFICATION AND DESCRIPTION

MAIN SPAN MATERIAL: ....... PRESTRESSED CONCRETE NO. OF MAIN SPANS:

MAIN SPAN TYPE: ............... STRINGER/MULTI-BEAM or GIRDER NO. OF APPR. SPANS:

# OF BEAMS, MAIN SPAN: .. 4 STRUCT. TOTAL LENGTH: .. 200.0 FT (61.0 M)

DECK TYPE: ......................... CONCRETE CAST-IN-PLACE MAX. SPAN LENGTH: .......... 67.0 FT (20.4 M)

WEARING SURFACE: .......... BITUMINOUS DECK WIDTH: ...................... 32.3 FT (9.8 M)

ABUT. FOUNDATIONS: ........ SPREAD FTG ON BEARING MAT'L CURB TO CURB WIDTH: ..... 28.2 FT (8.6 M)

PIER FOUNDATION(S): ........ SPREAD FTG ON BEARING MAT'L YEAR BUILT:

ABUTMENT / PIER MAT'L: ... CONCRETE YEAR RECONSTRUCTED: .. N/A

PROJ./PLAN REF. NO: ......... 1E4 / 3214A SKEW ANGLE: ..................... 0 °

NPS ROAD CLASS: .............. 1 - PRINCIPAL PARK ROAD FRACTURE CRITICAL: ........ NO

STRUCTURE HISTORY: ...... 1983-JOINT REPAIR; 1996-DECK STUDY; 2010-BRIDGE AND APPROACHES REPAVED.

LOCATION

NATCHEZ TRACE PARKWAY MILE POINT: ..................... 386.89 (KM PT 622.62)

STATE: ................................. TENNESSEE LOCATION: 1.1 MILES FROM TN ROUTE 20

FACILITY CARRIED: ............ NATCHEZ TRACE PARKWAY

FEATURE INTERSECTED: .. LITTLE SW AN CREEK

STRUCTURE EVALUATION SUMMARY

This prestressed concrete multi-girder bridge is in poor condition overall. The main problem is widespread cracking and delamination of both pier caps, with heavy efflorescence present; this is a serious condition which could affect the bearing seats and lead to a loss of load capacity if not repaired in the near future. Other problems include cracking with moderate to heavy efflorescence and numerous popouts on the deck underside, likely due to alkali-silica contamination; a lack of sealant in the expansion joints; widespread cracking and spalling of the curbs and railings;

moderate to severe cracking of the asphalt wearing surface over the abutments and piers and at the approach slab ends; debris and vegetation growth along the curblines; and a tree growing out of a weep hole at the north abutment.

Repairs are not required at this time, as the structure is programmed for replacement under Project NATR 1E10 with an anticipated completion date in 2015.

INSPECTION TEAM: D.K. JOHNSON, J.S. SMITHDEAL (CLARK NEXSEN)

CONDITION ASSESSMENT:

D. KEITH JOHNSON, P.E., FIELD TEAM LEADER

REPORT REVIEW :

MARCUS MILLER, P.E., SENIOR INSPECTION ENGINEER 703-404-6252

REPORT APPROVAL: DATE: 8/1/13

JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244

RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5570-004P

A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.

B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.

C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.

D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.

E (Special) - Structure is under construction or reconstruction.

B226 PRIORITY OF IMPROVEMENT

ITEM

NO.

MAINTENANCE RECOMMENDATIONS

(GENERALLY NOT FLHP ELIGIBLE)

QTY. UNIT COST

UNIT

ESTIMATE

COST

PRELIM.

PRELIM. MAINTENANCE TOTAL :

ITEM

NO.

REHABILITATION/RECONSTRUCTION

(TYPICALLY NEEDED WITHIN 5 YEARS)

QTY. UNIT

UNIT

COST ESTIMATES

PRELIM. COST

REHAB. RECONSTR.

PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :

COST ESTIMATE SUMMARY

PRELIM. MAINTENANCE TOTAL:

PRELIM. REHABILITATION TOTAL:

PRELIM. RECONSTRUCTION TOTAL:

TOTAL ITEMIZED COSTS:

$0 $0 $0

$0

PRELIMINARY ESTIMATE TOTAL* :

(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)

$0

REMARKS: Structure is programmed for replacement under Project NATR 1E10 with scheduled completion in 2015.

FIELD INSPECTION REPORT STRUCTURE NO. 5570-004P

CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223

N NOT APPLICABLE

9 EXCELLENT CONDITION

8 VERY GOOD CONDITION - no problems noted.

7 GOOD CONDITION - some minor problems.

6 SATISFACTORY CONDITION - structural elements show some minor deterioration.

5 FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.

4 POOR CONDITION - advanced section loss, deterioration, spalling, or scour.

3 SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.

Fatigue cracks in steel or shear cracks in concrete may be present.

2 CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.

1 “IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.

0 FAILED CONDITION - out of service; beyond corrective action.

CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS

G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)

58. DECK 5

1. DECK SLAB F

2. EXPANSION JOINTS F

3. WEARING SURFACE F

4. RIDEABILITY G

5. CURBS, SIDEWALKS, AND MEDIAN F

6. PARAPETS AND/OR RAILINGS F

7. DRAINS AND DRAINAGE F

8. UTILITIES N

9. DEFLECTION AND/OR VIBRATION G

10. OTHER N

59. SUPERSTRUCTURE 7

1. BEARING DEVICES

2. GIRDERS OR BEAMS

3. ARCH(ES) OR SLAB(S)

4. FLOOR BEAMS AND STRINGERS

5. TRUSSES

6. DIAPHRAGMS AND BRACING

7. PAINT

8. FASCIA(E)

9. DEFLECTION AND/OR VIBRATION

10. ALIGNMENT

11. OTHER

60. SUBSTRUCTURE

ABUTMENTS

1. BREASTWALLS OR COLUMNS

2. PILE BENTS

3. CAPS AND/OR BEARING SEATS

4. BACKWALLS AND/OR BULKHEADS

5. FOUNDATIONS (SPREAD FTG)

6. WINGWALLS

7. WEEP HOLES

8. EXPANSION JOINTS

9. EROSION AND/OR SCOUR

10. SETTLEMENT OR DEFLECTION

11. SLOPE PROTECTION

12. OTHER (VEGETATION)

PIER(S)

13. WALLS AND/OR COLUMNS

14. PILE BENTS

15. CAPS AND/OR BEARING SEATS

16. FOUNDATIONS

17. EROSION AND/OR SCOUR

18. SETTLEMENT OR DEFLECTION

19. OTHER (VEGETATION)

G G N N N G N N G G N

G N G G G G F N G G N G

G N P N G G G

58.1

58.2,3

58.5,6

58.7

59.2

60.1

60.5,9

60.6

60.7

ITEM REFERENCE AND REMARKS

WIDESPREAD MINOR TRANSVERSE AND RANDOM CRACKING WITH

MODERATE TO HEAVY EFFLORESCENCE AND NUMEROUS

POPOUTS ON DECK UNDERSIDE; DECK CONCRETE APPEARS TO BE

CONTAMINATED WITH CHLORIDES IN PLACES. SEE ALSO 59.2.

EXPANSION JOINTS PAVED OVER; MODERATE TO SEVERE

TRANSVERSE CRACKING OF ASPHALT WEARING SURFACE OVER

BOTH PIERS; MINOR TO MODERATE OVER ABUTMENTS.

MODERATE WATER LEAKAGE THROUGH JOINTS ONTO PIERS AND

ABUTMENTS. MINOR LONGITUDINAL CRACK IN SOUTH SPAN,

NORTHBOUND LANE.

POPOUTS PRESENT THROUGHOUT CURBS AND RAILINGS.

WIDESPREAD MINOR TO MODERATE RANDOM CRACKING WITH

EFFLORESCENCE ON CURBS WITH MINOR SPALLING. MINOR TO

MODERATE VERTICAL CRACKING ON RAILINGS AT EXPANSION

JOINTS. SOUTH SPAN HAS CONCENTRATED AREA OF MINOR

RANDOM CRACKING WITH EFFLORESCENCE ON BOTH SIDES.

MINOR ACCUMULATION OF DEBRIS AND VEGETATION GROWTH

ALONG EAST CURBLINE. DECK DRAINS ARE PARTIALLY CLOGGED.

MODERATE TO HEAVY EFFLORESCENCE ALONG GIRDER/DECK

INTERFACE. RUSTING OF EXPOSED REBAR CHAIRS ON BOTTOM

FACE OF GIRDERS IN ALL SPANS. MINOR DIAGONAL CRACKING OF

GIRDER WEBS EXTENDING FROM CORNERS OF END DIAPHRAGMS.

WATER LEAKAGE HAS STAINED BOTH ABUTMENTS (SEE 58.2,3).

TOP OF NORTH ABUTMENT FOOTING HAS BEEN EXPOSED BY

EROSION, BUT FOOTING WAS CAST IN BEDROCK. MINOR EROSION

ALONG SOUTH ABUTMENT AT WEST SIDE AND UNDER GIRDER #2.

MINOR VERTICAL AND DIAGONAL CRACKING AND POPOUTS ON

WINGWALLS.

TREE AND VINES GROWING OUT OF WEEP HOLES AT NORTH

ABUTMENT.

FIELD INSPECTION REPORT STRUCTURE NO. 5570-004P

ITEM REFERENCE AND REMARKS

STREAM BED COMPOSITION : 9.

AVERAGE CLEAR OPENING 8.

NORMAL VELOCITY 7.

ADEQUACY OF OPENING 6.

OTHER 5.

WATERWAY OBSTRUCTIONS 4.

CHANNEL PROTECTION3.

EROSION AND/OR SCOUR2.

ALIGNMENT1.

61. CHANNEL 8

G G N G N

MED

SUFF

27 FT.

ROCK

222. APPROACHES 6

OTHER 9.

ALIGNMENT 8.

SIGNS7.

SETTLEMENT 6.

EROSION5.

SURFACING4.

APPROACH GUARDRAIL 3.

2. RELIEF JOINTS

APPROACH SLABS1.

(CONCRETE APRON)

N N N F F F G G F

223. RETAINING WALL N

OTHER 6.

SETTLEMENT OR DEFLECTION5.

EROSION AND/OR SCOUR4.

FOUNDATION3.

WEEP HOLES2.

1. WALL

36. TRAFFIC AND SAFETY FEATURES

APPROACH GUARDRAIL ENDSD.

APPROACH GUARDRAILSC.

TRANSITIONSB.

BRIDGE RAILINGSA. 0

N N N

TRAFFIC SAFETY RATING CODES

0 - Does not meet standards or a safety feature is required and none is provided.

1 - Meets currently acceptable standards.

N - Not applicable or a safety feature is not required.

60.12,19 MINOR VINE GROWTH ON ABUTMENTS AND PIER COLUMNS.

60.13 MINOR POPOUTS AND WATER STAINING ON BOTH PIER COLUMNS.

60.15 MODERATE DELAMINATION ON BOTH PIER CAPS AROUND BEARING

AREAS FOR GIRDER #4. WIDESPREAD MODERATE CRACKING WITH

HEAVY EFFLORESCENCE THROUGHOUT BOTH PIER CAPS.

MODERATE TO SEVERE DELAMINATION ON SOUTH PIER, EAST

UNDERSIDE.

60.17 MINOR EROSION AT BASE OF SOUTH PIER COLUMN, SOUTH SIDE.

222.4 MINOR TO MODERATE TRANSVERSE CRACKING OF APPROACH

PAVEMENT OVER APPROACH SLAB ENDS.

222.5 MINOR UNDERMINING (2 1/2' UNDER) OF CONCRETE APRON AT

SOUTHEAST PARAPET END.

222.6 MINOR TO MODERATE SETTLEMENT OF NORTH APPROACH

PAVEMENT AT NORTH ABUTMENT.

222.7 TYPE 3 REFLECTIVE OBJECT MARKERS AT CORNERS OF

STRUCTURE. "LITTLE SWAN CREEK" SIGNS AT SOUTHEAST AND

NORTHWEST CORNERS OF STRUCTURE. TEMPORARY FLASHER

ON WEST RAILING AT SOUTH APPROACH.

222.9 MODERATE TO SEVERE RANDOM CRACKING OF CONCRETE APRON

AT SOUTHEAST PARAPET END.

36.A RAILING HEIGHT OF 1'-11" ON EAST SIDE DOES NOT MEET AASHTO

MINIMUM HEIGHT SPEC OF 2'-3" FOR TRAFFIC BARRIERS.

STRUCTURE LOAD RATING STRUCTURE NO. 5570-004P

TRUCK TYPE

INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)

TONS METRIC TONS TONS METRIC TONS

H 15 14 25 23

HS 19 17 32 29

TYPE 3 18 16 30 27

TYPE 3S2 24 22 40 36

TYPE 3-3 28 25 48 44

DESIGN LOADING: H15 (M13.5)

X CAPACITY MEETS OR EXCEEDS DESIGN LOAD

CAPACITY IS LESS THAN DESIGN LOAD

ORIGINAL LOAD RATING CALCULATION APPLICABLE

ORIGINAL LOAD RATING CALCULATION REVISED

DATE OF LOAD RATING CALCULATION:

LOAD RATING CONTROLLED BY:

REMARKS: RATING IS BASED ON DESIGN LOAD OF STRUCTURE.

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5570-004P

STRUCTURE IDENTIFICATION

(201) PARK: NATCHEZ TRACE PARKWAY (1) STATE: ....................................... 474 - TENNESSEE (TN)

(202) STRUCTURE NAME: .......... LITTLE SWAN CREEK BRIDGE (2) STATE HWY. AGENCY DIST:

(203) STRUCTURE KIND: ............ 1 - BRIDGE (3) COUNTY CODE: ........................ 101 - LEWIS

(204) STRUCTURE NUMBER: ..... 5570-004P (4) CITY/PLACE CODE:

(205) NPS REGION: .................... 4 - SOUTHEAST (5) INVENTORY ROUTE:

(206) ROUTE CODE NUMBER: ... 1 (6) FEATURES INTERSECTED:....... LITTLE SWAN CREEK

(207) ROAD SECTION NO: .......... 004P (7) FACILITY CARRIED: .................. NATCHEZ TRACE PARKWAY

(208) NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD (8) STATE STRUCTURE NO: .......... 5570004P0000000

(209) WITHIN NPS BNDRY?: ....... YES (9) LOCATION: ................................ 1.1 MILES FROM TN ROUTE 2

(210) OPERATING UNIT: ............. M. LEWIS (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)

(211) PROJECT NO(S): ................ 1E4 (11) MILE POINT: ............................. 386.89 (KM PT 622.62)

(212) DRAWING NUMBERS: ....... 3214A (27) YEAR BUILT:

(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED: .... N/A

(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE (20) TOLL: ........................................ 3 - FREE ROAD

(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE

STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE

(43A) MAIN STR. MATERIAL: ..

(43B) MAIN STR. TYPE:

(45) NO. OF MAIN SPANS:

(48) MAX. SPAN LENGTH:

(49) STRUCTURE LENGTH:

(216A) ABUTMENT #1 FDN:

(216B) ABUTMENT #2 FDN:

(217A) PREDOM. PIER FDN.: ..

(217B) SECOND. PIER FDN: ...

(107) DECK TYPE:

5 - PRESTRESSED CONCRETE

02 - STRINGER/MULTI-BEAM or GIRDER

67.0 FT (20.4 M)

200.0 FT (61.0 M)

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

1 - CONCRETE CAST-IN-PLACE

(44A) APPR. STR. MATERIAL: ........ 0 - OTHER

(44B) APPR. STR. TYPE: ................ 00 - OTHER

(46) NO. OF APPROACH SPANS: .. 0

(108) WEAR SURFACE/PROTECT SYSTEM:

A) TYPE WEARING SURFACE: .. 6 - BITUMINOUS

B) TYPE MEMBRANE: ................. 0 - NONE

C) TYPE PROTECTION: .............. 0 - NONE

(218) IS SALT USED?: ..................... NO

LOAD RATING AND POSTING

(31) DESIGN LOAD: ................. 2 - H15 (M13.5) (41) LOAD RESTRICTION: ......... R - POSTED (OTHER)

(66) INVENTORY RATING: ...... 19.0 TONS (17.0 METRIC TONS) (70) BRIDGE POSTING: .............. 3 - POSTING REQUIRED

(64) OPERATING RATING: ...... 32.0 TONS (29.0 METRIC TONS)

INSPECTION DATES

(90) INSPECTION DATE: 3/13 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):

(219) ADD. STUDIES NEEDED: Y - 1 - DECK SURVEY (A) FRACTURE CRITICAL: ... NO

INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE

(B) UNDERWATER: .............. NO

(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :

(C) SPECIAL INSPECTION: .. NO

INSP. EVERY: MONTHS - LAST INSP. :

o

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5570-004P

GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA

(16) LATITUDE: ............................. 35°31'01.90" (51) CURB TO CURB WIDTH: ........... 28.2 FT (8.6 M)

(17) LONGITUDE: ......................... 87°26'46.30" (52) DECK WIDTH: ............................ 32.3 FT (9.8 M)

(19) DETOUR LENGTH: ............... 0 MI (0 KM) (32) APPR. ROADWAY WIDTH: ........ 34.0 FT (10.4 M)

(28A) LANES ON STRUCT: .......... 02 (213) APPR. PAVEMENT WIDTH: ..... 22.0 FT (6.7 M)

(28B) LANES UNDER STRUCT: ... 00 LEFT SHOULDER: .................. 6.0 FT (1.8 M)

(42A) SERVICE ON: ..................... 1 - HIGHWAY RIGHT SHOULDER: ................ 6.0 FT (1.8 M)

(42B) SERVICE UNDER: .............. 5 - WATERWAY (33) BRIDGE MEDIAN: ....................... 0 - NO MEDIAN

(29) AVG. DAILY TRAFFIC: .......... 480 (34) SKEW ANGLE: ............................ 0 °

(30) YEAR OF ADT: ...................... 2007 (35) DECK FLARE?: ........................... NO

(114) FUTURE ADT: ..................... 488 (47) TOTAL HORIZ. CLEARANCE: .... 28.2 FT (8.6 M)

(115) YEAR OF FUTURE ADT: ..... 2027 (50) SIDEWALKS:

(101) PARALLEL STRUCTURE: ... N - NONE LEFT : ...................................... 0.0 FT (0.0 M)

(38) NAVIGATION CONTROL?: ... 0 RIGHT : ................................... 0.0 FT (0.0 M)

(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M) (214) BRIDGE RAIL TYPE:

(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M) RAIL CONFIGURATION: ......... 1 - FULL HEIGHT (NO PARAPE

(111) ABUT. OR PIER PROT: ....... MATERIAL: .............................. 1 - CONCRETE

DESIGN TYPE: ........................ 1 - CONTINUOUS RAIL

LATERAL UNDERCLEARANCE:

(55) RIGHT: ....................... 0.0 FT (0.0 M) (215) BRIDGE RAIL HEIGHT: ............ 1.92 FT (0.59 M)

(56) LEFT: ......................... 0.0 FT (0.0 M) (53) MIN. VRT. CLEAR. OVER DECK: 99.99 FT (99.99 M)

(54) MIN. VRT. UNDERCLEARANCE: 0.00 FT (0.00 M)

CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST

(58) DECK:

(59) SUPERSTRUCTURE:

(60) SUBSTRUCTURE:

(61) CHANNEL:

(62) CULVERT: ........................... N

(222) APPROACHES:

(223) RETAINING WALL: ........... N

(36) TRAFFIC SAFETY FEAT: ... 0NNN

(75A) TYPE OF WORK:

(75B) WORK DONE BY:

(76) IMPROVEMENT LENGTH: ..

(67) STRUCTURAL EVALUATION:

(68) DECK GEOMETRY:

(69) UNDERCLEARANCES:

(71) WATERWAY ADEQUACY:

(72) APPROACH ALIGNMENT:

(113) SCOUR CRITICAL:

(225) PURPOSE OF IMPROVEMENT:

(226) PRIORITY OF IMPROVEMENT:

(227) MAINTENANCE COST:

(228) REHAB./RECONSTR. COST: ...

(229) CONSTRUCTION COST:

N

8 - Stable; scour above top of fo

1 - MAINTENANCE

B - MAJOR

$0

$0

$0

ADDITIONAL INFORMATION

(230) STRUCTURE HISTORY:

1983-JOINT REPAIR; 1996-DECK STUDY; 2010-BRIDGE AND APPROACHES REPAVED.

(231) ADDITIONAL CONSIDERATIONS:

(330) ADDITIONAL CONFIG. INFO.:

http:87�26'46.30 http:35�31'01.90

APPENDIX STRUCTURE NO. 5570-004P

PHOTOGRAPHS STRUCTURE NO. 5570-004P

PHOTO #1 - LOOKING SOUTHBOUND TOWARD TUPELO

FLOW

PHOTO #2 - EAST (UPSTREAM) SIDE

PHOTO #3 - GENERAL TOPSIDE VIEW

LOOKING SOUTH

PHOTO #4 - TYPICAL TRANSVERSE CRACKING

OF ASPHALT WEARING SURFACE OVER BOTH

PIERS; WEARING SURFACE OVER NORTH

PIER SHOWN

PHOTO #5 - LONGITUDINAL CRACK IN SOUTH

SPAN, NORTHBOUND LANE

PHOTO #6 - TYPICAL TRANSVERSE CRACKING

OF APPROACH PAVEMENT OVER APPROACH

SLAB ENDS; NORTH APPROACH SHOWN

PHOTO #7 - SETTLEMENT OF NORTH APPROACH PAVEMENT AT

NORTH ABUTMENT

PHOTO #8 - TYPICAL RANDOM CRACKING WITH EFFLORESCENCE ON

CURBS; WEST CURB OVER NORTH ABUTMENT SHOWN

PHOTO #9 - TYPICAL SPALLING OF CURBS;

EAST CURB OVER SOUTH PIER SHOWN

PHOTO #10 - TYPICAL ACCUMULATION OF

DEBRIS AND VEGETATION GROWTH ALONG

EAST CURBLINE; NORTH SPAN SHOWN

PHOTO #11 - TYPICAL PARTIALLY CLOGGED DECK DRAINS; EAST

SHOULDER, NORTH SPAN SHOWN

PHOTO #12 - UNDERMINING OF CONCRETE APRON AT SOUTHEAST

PARAPET END

PHOTO #13 - GENERAL UNDERSIDE VIEW LOOKING NORTH, SOUTH

SPAN

PHOTO #14 - TYPICAL TRANSVERSE CRACKING WITH

EFFLORESCENCE ON DECK UNDERSIDE; CENTER BAY, CENTER SPAN

SHOWN

PHOTO #15 - TYPICAL EFFLORESCENCE ALONG GIRDER/DECK

INTERFACE; GIRDER #4, SOUTH SPAN SHOWN; ALSO NOTE TYPICAL

RANDOM CRACKING WITH EFFLORESCENCE ON DECK UNDERSIDE

PHOTO #16 - TYPICAL DIAGONAL CRACKING OF GIRDER WEBS

EXTENDING FROM CORNERS OF END DIAPHRAGMS; EAST SIDE OF

BEAM #2 AT NORTH ABUTMENT SHOWN

PHOTO #17 - GENERAL VIEW OF SOUTH ABUTMENT

PHOTO #18 - TOP OF NORTH ABUTMENT FOOTING EXPOSED BY

EROSION

PHOTO #19 - EROSION ALONG SOUTH ABUTMENT UNDER GIRDER #2

PHOTO #20 - TYPICAL VERTICAL AND DIAGONAL CRACKING OF

WINGWALLS; SOUTHEAST WINGWALL SHOWN

PHOTO #21 - TREE AND VINES GROWING OUT

OF WEEP HOLE AT NORTH ABUTMENT

PHOTO #22 - GENERAL VIEW OF SOUTH PIER,

SOUTH FACE

PHOTO #23 - TYPICAL POPOUTS, WATER STAINING AND VINE

GROWTH ON BOTH PIER COLUMNS; SOUTH PIER, SOUTH FACE

SHOWN

PHOTO #24 - TYPICAL CRACKING WITH EFFLORESCENCE

THROUGHOUT BOTH PIER CAPS; SOUTH PIER, EAST END SHOWN;

ALSO NOTE EFFLORESCENCE ALONG GIRDER/DECK INTERFACE

PHOTO #25 - TYPICAL CRACKING WITH EFFLORESCENCE ON

UNDERSIDE OF BOTH PIER CAPS; NORTH PIER, WEST SIDE SHOWN

PHOTO #26 - UPSTREAM CHANNEL

PHOTO #27 - DOWNSTREAM CHANNEL

File details come from the government source that posted it. Updated .