Drftwd_Pkng_Lighting_Plans_05-31-24-SS.pdf
PDF 2 MB Posted
- Attached to
- Driftwood Road Municipal Parking Facility
- Solicitation number
- ITB 24-34
- Issued by
- Walton County, Florida
About this file
This electrical drawings and specifications document supports the Driftwood Road Municipal Parking Facility project in Santa Rosa Beach, Florida, a municipal infrastructure development by Walton County. The project requires installation of a complete electrical system for the parking facility, including new underground conduit and wiring for the proposed parking lot, twelve light poles with LED amber-type luminaries for illumination, connection of light pole-mounted luminaries to Panel P through a timer, and all associated junction/pull boxes and grounding systems. The electrical work must comply with the National Electrical Code (NEC) 2020 Edition and all governing municipal, state, and local codes. All materials shall be new, American-manufactured, and bear Underwriter's Laboratory and Union labels as applicable. The contractor must maintain a complete set of electrical prints marked with colored pencils indicating all changes and deliver the marked set to the architect/engineer upon completion. All work shall be performed by a licensed electrical contractor in a first-class manner and must be completed and fully operational to the acceptance of the owner/engineer. The contractor is responsible for all permits, fees, inspections, tests, and fines as required. All electrical conductors must be copper with a minimum size of #12 AWG, installed in Schedule 40 PVC conduit for underground installations and mechanical metallic conduit for interior wiring. The system must test free from short circuits and grounds upon completion, and the contractor shall guarantee the entire electrical work, including parts and labor, for a period of one year after final written acceptance by the owner.
The electrical scope is limited to the parking lot illumination system as specified, with the lighting circuit consisting of 2#10 THWN copper conductors and 1#10 THWN copper grounding conductor in 1-inch conduit. The luminaire schedule indicates six fixtures of Type A and ten fixtures of Type B, all LED-based at 170 watts and 240 volts, mounted on 24-foot poles with damp location rating and Type III distribution. The photometric calculations show an average illuminance of 1.80 foot-candles across the parking lot with a maximum of 3.4 and minimum of 1.0, demonstrating compliance with FBC 13-413 and NEC standards. Voltage drop calculations confirm that feeder sizing is appropriate, with a voltage drop of 0.5 percent from Panel P to the farthest light pole (LP#12) at 575 feet distance using #10 AWG conductors. The contractor must coordinate trenching with existing underground utilities and provide proper marker tape over conduits; drawings do not show any existing underground utilities. All conduits in trenches shall be installed minimum 24 inches deep in 6 inches of clean sand with Schedule 40 PVC conduit and 6-inch-wide red marker tape running continuous over the conduit for identification.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ELECTRICAL GENERAL NOTES
1. PRIOR TO BID, VISIT JOB SITE AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS.
2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (N.E.C.) 2020 EDITION, AND GOVERNING MUNICIPAL, STATE AND LOCAL CODES, AND SHALL BE PERFORMED IN A THOROUGH AND WORKMAN LIKE MANNER BY COMPETENT WORKMEN. ALL MATERIAL SHALL BE NEW AND SHALL BEAR THE U.L.
LABEL.
3. CONTRACTOR SHALL GUARANTEE THE ENTIRE ELECTRICAL WORK, INCLUDING PARTS AND LABOR FOR A PERIOD OF ONE (1) YEAR AFTER FINAL WRITTEN
ACCEPTANCE OF OWNER.
4. THIS CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS, TESTS, FINES, ETC. AS REQUIRED.
5. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS MANNER AND SHALL BE COMPLETED AND FULLY OPERATIVE TO THE
ACCEPTANCE OF THE OWNER/ENGINEER.
6. MAINTAIN A COMPLETE SET OF ELECTRICAL PRINTS FOR INDICATING ALL CHANGES. USE COLORED PENCIL TO MARK CHANGES AT THE TIME OF EXECUTION AND
DELIVER THE SET TO ARCHITECT/ENGINEER UPON COMPLETION.
7. ALL MATERIALS SHALL BE NEW, OF AMERICAN MANUFACTURE, AND BEAR THE UNDERWRITER'S LABORATORY AND UNION LABELS AS APPLICABLE. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO COORDINATE DELIVERY SCHEDULES OF MATERIALS.
8. CIRCUIT BREAKERS SHALL BE MOLDED CASE, BOLT-ON TYPE, OF QUICK-MAKE ACTION, RATED MINIMUM AT 10,000 (120V), 14,000 (277/480V) AIC RMS SYMMETRICAL.
EACH MOLDED CASE CIRCUIT BREAKER SHALL HAVE THERMAL MAGNETIC TRIP DEVICE.
9. LIGHTING FIXTURES SHALL BE COMPLETE WITH ALL NECESSARY WIRING, LAMP HOLDERS REFLECTORS, GLASSWARE AND MOUNTING ACCESSORIES AS REQUIRED.
10. CONTRACTOR SHALL MAKE ALL NECESSARY EXCAVATIONS, CUTTING AND DO ALL REPATCHING AS NECESSARY FOR THE PROPER EXECUTION OF THIS WORK.
11. AFTER COMPLETION OF THE INSTALLATION, THE SYSTEM SHALL TEST FREE FROM SHORT CIRCUITS AND GROUNDS.
12. ALL ELECTRICAL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. CONDUITS SHALL COMPLY WITH N.E.C. PVC CONDUIT SHALL BE SCHEDULE 40 AND SHALL BE USED WHERE CONDUIT IS RUN IN CONCRETE SLABS, OR UNDERGROUND. ELECTRICAL METALLIC CONDUIT SHALL BE USED ON ALL INTERIOR WIRING. GRS CONDUIT
SHALL BE USED ON EXTERIOR WIRING. .
13. SHOP DRAWINGS AND MANUFACTURER'S LITERATURE: SUBMIT FOR APPROVAL, PROPERLY IDENTIFIED MANUFACTURER'S LITERATURE GIVING MATERIALS, FINISHES, ACCESSORIES AND INSTALLATION DIRECTIONS, WHERE REQUIRED, OF ALL THE ELECTRICAL EQUIPMENT INCLUDING THE FOLLOWING ELECTRICAL
EQUIPMENT.
A. CONDUITS AND RACEWAYS
B. CONDUCTORS
C. OUTLET, PULL AND JUNCTION BOXES
D. OVERCURRENT PROTECTIVE DEVICES
E. LIGHTING FIXTURES, LAMPS AND POLES
14. ALL CONDUCTORS SHALL BE COPPER. NO CONDUCTOR SHALL BE SMALLER THAN #12 AWG. INSULATION SHALL BE XHHW AND SHALL BE RATED FOR 600 VOLTS.
INSTALL A GROUNDING CONDUCTOR IN ALL CONDUITS SIZED PER N.E.C.
15. VERIFY SERVICE VOLTAGE BEFORE ORDERING ANY ELECTRICAL EQUIPMENT.
16. SPLICES FOR #6 AWG OR SMALLER SHALL BE MADE WITH U.L. LISTED MECHANICAL PRESSURE CONNECTORS. SPLICES FOR #4 AWG OR LARGER SHALL BE MADE WITH MECHANICAL PRESSURE, SOLDERLESS CONNECTORS, AND SHALL BE BURNDY SERVITS OR APPROVED EQUAL.
17. PANELS SHALL BE OF THE TYPE AND NUMBER OF BREAKERS AS INDICATED ON "PANEL SCHEDULE". STENCIL PANEL DESIGNATION ON INSIDE OF PANEL. MASTER KEY ALL PANEL LOCKS. ALL TWO-POLE BREAKERS SHALL BE COMMON TRIP. PROVIDE TYPE WRITTEN SCHEDULE IN EACH PANELBOARD. CONNECTION TO MAIN BUS SHALL BE WITH BURNDY ANNULAR COMPRESSION LUGS. PANELS SHALL BE RATED FOR SERVICE ENTRANCE WHERE APPLICABLE.
18. GROUNDING SHALL BE IN ACCORDANCE WITH ARTICLE 250 OF THE N.E.C.
19. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE WORK.
20. ELECTRICAL CONTRACTOR TO COORDINATE HIS WORK WITH ALL OTHER TRADES.
21. ALL METERS, MAIN SWITCHES, AND SUB-MAIN SWITCHES SHALL BE CLEARLY MARKED.
22. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE TRENCHING WITH EXISTING UNDERGROUND UTILITIES. DRAWINGS DO NOT SHOW ANY EXISTING
UNDERGROUND UTILITIES.
THE ELECTRICAL SCOPE OF WORK IS LIMITED TO:
- NEW UNDERGROUND CONDUIT AND WIRES FOR PROPOSED PARKING LOT.
- NEW LIGHT POLES AND LED AMBER TYPE LUMINARIES FOR ILLUMINATION.
- CONNECT LIGHT POLE MOUNTED LUMINARIES TO PANEL P THRU A TIMER.
NO SCALE
6" 6"
12" MAX
TYPICAL SITE LIGHTING TRENCH DETAIL
LUMINAIRE DETAIL TYP.
24 3/16"
29 1/8"
14 1/4"
4 1/8"
NO SCALE
16" 14"12"
9 7/8"
3/16"
25 1/2" 12" 23 31/64"
19 3/8"
23 1/4" 2"
2"
13 3/4"
JUNCTION/PULL BOX DETAIL
NO SCALE
LIGHT POLE & BASE DETAIL (TYP.)
NO SCALE
24"
7'-0"
1'-6"
1'-0"
24'-0"
GRADE
LIGHT POLE DETAIL
NO SCALE
C
LI
EN
T
PR
O
JE
C
T
TA
SK
1 2 3 4 5O R
IG
IN
AL
R
EV
IS
IO
N
S:
D
EC
EM
BE
R
DR
IF
TW
OO
D
RD
MU
NI
CI
PA
L P
AR
KI
NG
F
AC
ILI
TY
(1
P
LA
NS
N
. M on ro e
S t.
B ui ld in g C
T al la ha ss ee
, F L
0.
5.
F
B P
R C er tif ic at e of
A ut ho riz at io n N o.
JF JF PL
T
E1
SH
EE
T
JO
B
N O
D R
AW
N
D
ES
IG
N
ED
C H
EC
KE
D
Q C
R V
PE
D
R O
L . T
R
EV
IN
FL
P E#
1"
0'
PH
O
TO
M
ET
R
IC
P
LA
N
AutoCAD SHX Text
VOLTAGE DROP CALCULATIONS
AutoCAD SHX Text
FROM PANEL P TO THE FARTHEST LIGHT POLE WITH "LP#12"
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
ELECTRICAL TOTAL DEMAND LOAD
AutoCAD SHX Text
CIRCUIT AMPERES (25%%% SPARE INCLUDED)
AutoCAD SHX Text
LENGTH OF CONDUCTORS
AutoCAD SHX Text
NEC 310-16 SIZE OF CONDUCTORS
AutoCAD SHX Text
CIRCULAR MIL AREA
AutoCAD SHX Text
VOLTAGE DROP
AutoCAD SHX Text
VOLTAGE DROP %
AutoCAD SHX Text
1. RESISTANCE OF COPPER CALCULATED AT 12.9 OHMS/MILxFT AT 75%%D.
AutoCAD SHX Text
2. COMPLIES WITH FBC 13-413 AND NEC 210.19(A) (1) FPN#4.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 0.9
AutoCAD SHX Text
AutoCAD SHX Text
#10 AWG
AutoCAD SHX Text 10.38
AutoCAD SHX Text 1.3
AutoCAD SHX Text 0.5
AutoCAD SHX Text
VA
AutoCAD SHX Text A
AutoCAD SHX Text
FT
AutoCAD SHX Text
KCMIL
AutoCAD SHX Text V
AutoCAD SHX Text
AutoCAD SHX Text
3. FEEDERS NEED TO BE OVERSIZED DUE VOLTAGE DROPS.
AutoCAD SHX Text NOTE: WHERE MORE THAN ONE CONDUIT IS INSTALLED IN THE TRENCH, PROVIDE THE PROPER MARKER TAPE OVER EACH CONDUIT.
AutoCAD SHX Text
LIGHTING CIRCUIT CONDUCTORS
AutoCAD SHX Text
6" MINIMUM CLEAN SAND
AutoCAD SHX Text
SCHEDULE 40 PVC CONDUIT
AutoCAD SHX Text
MECHANICALLY TAMPED BACKFILL (98% COMPACTION - SEE SPECIFICATIONS)
AutoCAD SHX Text
TOP SOIL (LAWN AREAS ONLY)
AutoCAD SHX Text IN PAVEMENT, PATCH IN ACCORDANCE WITH SPECIFICATIONS. IN LAWN AREA, GRADE AND SEED TO MATCH EXISTING
AutoCAD SHX Text
EXISTING GRADE
AutoCAD SHX Text
6" WIDE MARKER RED TAPE TO RUN CONTINUOUS OVER CONDUIT.
AutoCAD SHX Text
WALL
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text
SECTION A-A
AutoCAD SHX Text
SECTION B-B
AutoCAD SHX Text
1/2"-13UNC X 2 1/2"
AutoCAD SHX Text SS HEX BOLTS (2x)
AutoCAD SHX Text
3/4" HIGH LETTERS
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
HIGH DENSITY
AutoCAD SHX Text
POLYMER CONCRETE
AutoCAD SHX Text
5/8" HIGH LETTERS
AutoCAD SHX Text 20K
AutoCAD SHX Text
LIFTING EYE
AutoCAD SHX Text
OPEN BASE
AutoCAD SHX Text 24'-0"
AutoCAD SHX Text C
AutoCAD SHX Text Grade
AutoCAD SHX Text 12"
AutoCAD SHX Text
LED LUMINAIRES (TYP). REFER TO LIGHT FIXTURE SCHEDULE.
AutoCAD SHX Text 9 1/2''-10 1/2''
AutoCAD SHX Text
BOLT CIRCLE
AutoCAD SHX Text
10"X10" BASE 6061-T6, " THICKNESS34" THICKNESS
AutoCAD SHX Text
3.00 OD. X .226 WALL
AutoCAD SHX Text
ALUMINUM PIPE TENON
AutoCAD SHX Text 6061-T6
AutoCAD SHX Text
5.00 OD. X .250 WALL
AutoCAD SHX Text
ALUMINUM TUBE
AutoCAD SHX Text 6061-T6
AutoCAD SHX Text R5.00
AutoCAD SHX Text
24' ROUND STRAIGHT ALUMINUM POLE. POWDER COATED PAINT
AutoCAD SHX Text
12" GRAVEL BASE.
AutoCAD SHX Text
MOUNTING ASSEMBLY TO ROUND TOP LIGHT POLE FOR SINGLE LUMINAIRE
AutoCAD SHX Text
MOUNTING ASSEMBLY TO ROUND TOP LIGHT POLE FOR TWO LUMINARIES
AutoCAD SHX Text
LED LUMINAIRE
AutoCAD SHX Text
2½"X5"HAND HOLE WITH 3AMP FUSE HOLDER AND GROUND LUG TO BOND METAL POLE.
AutoCAD SHX Text
TRAFFIC RATED J.BOX COVER SEE MORE DETAILS ON THIS SHEET
AutoCAD SHX Text
JUNCTION BOX NONMETALIC WATERPROOF, SCREW COVER WITH GASKET
AutoCAD SHX Text PROVIDE 1#6 THHW CU AS GROUNDING CONDUCTOR CONNECTED TO 3/4" X 10' LONG COOPER-CLAD GROUND ROD (TYP).
AutoCAD SHX Text
IN AND OUT CONDUIT FOR EACH LIGHT POLE, REFER TO SITE FOR MORE INFORMATION.
AutoCAD SHX Text CONTRACTOR TO PROVIDE MANUFACTURER DOCUMENTATION INCLUDING LIGHT POLE FOUNDATION STRUCTURAL DETAIL AND WIND LOAD PRESSURE CALCULATIONS AS PER STATE ORDINANCES.
AutoCAD SHX Text
METAL LIGHTING POLE
AutoCAD SHX Text
CONCRETE BASE
TREV8626
EX
IS
TI
N
G
-W
AY
(F U
TU
R
E 1-
W
AY
N O
R
TH
8 GOLF CART
PARKING SPACES
ELECTRIC
VEHICLE
CHARGING
STATION
PARKING
SPACES
7 GOLF CART
PARKING SPACES
EX
IS
TI
N
G
-W
AY
(F U
TU
R
E 1-
W
AY
N O
R
TH
30+/- BICYCLE
PARKING SPACES
PO
R
C H
PU
BLIC
R
ESTR
O O
M
AN
D
TR
AN
SIT
FAC
ILITY
BU
ILD
IN
G
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO BFO BFO BFO BFO BFO BFO BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
S
S
S
S S
O H
L
O H
L
O H
L
O H
L
OHL
OHL
OHL
OHL
O H
L O
H L
O H
L O
H L
O H
L
OHL
OHL
OHL
OHL
O O O O O O O
O O
O O
O O
O O
O O
O O
O O
TT
W W
W
20" S
22" S 22"
S
20" S
20" S
20" S
20" S
15" S 22"
S
22" S
14" S
22" S
E
T
T
W L
W L
W L
W L
W L
W L
W L
W L
W L
W L
W L
W L
BF
O
BF
O
BFO
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0
0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.00.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
EGS
EGS
EGS
EGS
EGS
EGS
EGS
EGSEGS
EGS
B
B B
B
B
B
B
B
B B
A
A
A
A
AA
1.2 1.2 1.3 1.5 1.6 1.7 1.6
1.3 1.3 1.4 1.4 1.5 1.5 1.5 1.3 1.5 1.5 1.0 1.4 1.5 1.2 1.4 1.5 1.8 1.8
1.2 1.4 1.5 1.6 1.7 1.7 1.7 1.7 1.7 1.7 1.6 1.6 1.6 1.6 1.3 1.5 1.6 1.8 1.8 1.7 1.7 1.5
1.4 1.5 1.6 1.8 1.8 1.9 2.0 2.0 1.9 1.9 1.8 1.7 1.7 1.7 1.7 1.4 1.6 1.7 1.8 1.8 1.8 1.6 1.5
1.5 1.7 1.8 1.9 2.0 2.1 2.1 2.1 2.1 2.0 1.9 1.8 1.8 1.8 1.8 1.9 2.0 1.8 2.1 1.9 1.8 1.6 1.5
1.6 1.8 1.9 2.0 2.0 2.1 2.0 2.0 2.0 1.9 1.8 1.8 1.8 1.8 1.9 1.9 2.0 2.0 2.0 2.0 1.9 1.7 1.4 1.1
1.6 1.8 1.9 2.0 2.1 2.1 2.1 2.0 1.9 1.8 1.7 1.9 1.9 1.9 1.9 1.9 1.7 1.6 1.4 1.1
2.0 2.1 2.1 2.1 2.1 2.0 1.9 1.7 1.6 1.9 1.8 1.8 1.7 1.6 1.5 1.3 1.1
1.9 2.0 2.0 2.0 1.9 1.8 1.7 1.4 1.4 1.8 1.8 1.8 1.8 1.8 1.7 1.6 1.5 1.4 1.2 1.0
1.8 2.1 2.3 2.2 2.0 1.6 1.4 1.2 1.2 1.4 1.7 1.7 1.7 1.8 1.8 1.7 1.5 1.4 1.4 1.2 1.0
1.5 1.6 1.7 1.7 1.8 1.6 1.5 1.4 1.4 1.2 1.0
1.4 1.7 1.7 1.7 1.8 1.8 1.5 1.4 1.4 1.2 1.0
1.4 1.7 1.7 1.7 1.8 1.8 1.4 1.3 1.4 1.2 1.1
1.6 1.7 1.8 1.7 1.8 1.7 1.6 1.6 1.4 1.2 1.1
1.8 1.7 1.8 1.7 1.7 1.7 1.6 1.5 1.4 1.2 1.1
1.9 1.7 1.8 1.7 1.8 1.7 1.6 1.5
1.9 1.8 1.8 1.8 1.6 1.7 1.6 1.6
1.7 1.8 1.9 1.8 1.6 1.6 1.5 1.4
1.5 1.8 1.9 1.5 1.6 1.6 1.6 1.6 1.5 1.3 1.0
1.5 1.8 2.0 1.5 1.6 1.6 1.8 1.7 1.6 1.3 1.1
1.4 1.7 1.9 2.0 1.5 2.0 1.9 1.8 1.6 1.4 1.2
1.4 1.7 1.9 2.0 1.5 2.0 1.9 1.7 1.5 1.4 1.2
1.4 1.8 1.9 2.0 2.1 2.0 1.9 1.7 1.5 1.4 1.2
1.8 1.9 2.1 2.1 2.1 1.9 1.7 1.7 1.4 1.2
1.8 1.1 2.3 2.2 2.2 2.1 1.7 1.6 1.3 1.0
2.2 2.1 2.1 1.7 1.5 1.3 1.0
2.3 2.4 2.3 2.2 2.0 1.7 1.4 1.3 1.0
2.5 2.4 2.4 2.3 2.1 2.0 1.7 1.5 1.2 1.0
2.8 2.5 2.5 2.3 2.2 2.0 1.8 1.6 1.3 1.0
2.8 2.6 2.5 2.4 2.3 2.1 1.9 1.6 1.4 1.0
2.6 2.6 2.6 2.6 2.4 2.3 2.0
2.4 2.7 2.8 2.6 2.5 2.4 2.1
2.5 2.8 2.8 2.6 2.5 2.4 2.1 1.7 1.3 1.1 1.0
2.3 2.6 2.6 2.5 2.4 2.3 2.1 1.7 1.4 1.1 1.0
2.4 2.5 2.5 2.3 2.3 2.2 2.0 1.7 1.4 1.2 1.0
2.5 2.5 2.4 2.3 2.2 2.1 1.9 1.6 1.4 1.1 1.0
2.7 2.6 2.4 2.3 2.3 2.1 1.9 1.6 1.4 1.1 1.0
2.8 2.9 2.8 2.6 2.5 2.2 1.9 1.7 1.4 1.2 1.0
3.2 3.2 3.0 2.8 2.6 2.4 2.0 1.7 1.4 1.2 1.0
2.2 2.3 2.3 2.5 2.6 2.5 2.5 2.6 2.8 3.2 3.4 3.0 2.8 2.7 2.4 2.1 1.8 1.5 1.3 1.0
2.1 2.2 2.3 2.6 2.8 2.8 2.6 2.5 2.7 2.7 2.6 2.4 2.1 1.8 1.6 1.3 1.0
2.0 2.0 2.2 2.4 2.5 2.5 2.4 2.3 2.5 2.6 2.5 2.4 2.1 1.9 1.6 1.4 1.1
1.5 1.6 1.8 1.9 2.1 2.0 2.0 2.4 2.4 2.3 2.3 2.4 2.6 2.7 2.7 2.6 2.5 2.3 2.3 2.1 1.9 1.6 1.4 1.2
1.6 1.7 1.9 2.1 1.9 2.3 2.1 2.4 2.3 2.2 2.3 2.5 2.6 2.6 2.5 2.4 2.2 2.1 1.9 1.8 1.6 1.4 1.2
1.5 1.6 1.8 1.9 2.1 2.1 2.2 1.7 2.1 2.1 2.1 2.3 2.4 2.4 2.3 2.2 2.0 1.9 1.9 1.7 1.6 1.4 1.2
1.3 1.4 1.6 1.7 1.8 1.8 1.8 1.8 1.8 1.8 1.9 2.0 2.1 2.1 2.0 1.9 1.8 1.7 1.7 1.6 1.5 1.3 1.1
1.1 1.4 1.5 1.6 1.6 1.6 1.5 1.5 1.4 1.8 1.8 1.7 1.7 1.6 1.6 1.4 1.3
1.2 1.3 1.3 1.3 1.3 1.3 1.3 1.5 1.5 1.5 1.5 1.2 1.4 1.2 1.2 1.1
1.0 1.1 1.1 1.1 1.1 1.1 1.1 1.3 1.3 1.3 1.3 1.2 1.0 1.2 1.1 1.0
1.0 1.0 1.0 1.0 1.0 1.0 1.0
Luminaire Schedule Symbol Qty Label Mounting - MH Total Lamp Lumens LLF Description
6 A (AMBER-TYPE III) POLE MOUNTED - 24FT 7080 0.95 DSX2 LED P4 AMBLW T3M G1
Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min
EAST out of PL Illuminance Fc 0.0 N.A. N.A.
North out of PL Illuminance Fc 0.0 N.A. N.A.
Parking Lot Illuminance Fc 1.80 3.4 1.0 1.80 3.40
SOUTH out of PL Illuminance Fc 0.0 N.A. N.A.
WEST out of PL Illuminance Fc 0.0 N.A. N.A.
10 B (AMBER-TYPE III) POLE MOUNTED - 24FT 7080 0.95 DSX2 LED P4 AMBLW T3M BLC/EGS*
"BLC": Backlight Control to set up to "minimum" and "EGS": Option to be ordered for External Glare Shield.
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
C
LI
EN
T
PR
O
JE
C
T
TA
SK
1 2 3 4 5O R
IG
IN
AL
R
EV
IS
IO
N
S:
D
EC
EM
BE
R
DR
IF
TW
OO
D
RD
MU
NI
CI
PA
L P
AR
KI
NG
F
AC
ILI
TY
(1
P
LA
NS
N
. M on ro e
S t.
B ui ld in g C
T al la ha ss ee
, F L
0.
5.
F
B P
R C er tif ic at e of
A ut ho riz at io n N o.
JF JF PL
T
E2
SH
EE
T
JO
B
N O
D R
AW
N
D
ES
IG
N
ED
C H
EC
KE
D
Q C
R V
PE
D
R O
L . T
R
EV
IN
FL
P E#
N
1"
0'
PH
O
TO
M
ET
R
IC
S
IT
E
PL
AN
SCALE IN FEET
010' 20' 40'
AutoCAD SHX Text OWNER: RICH RENTALS LLC C/O PAK PROPERTIES LLC PARCEL ID: 30-2S-21-42290-000-0921 OFFICIAL RECORD BOOK 3213, PAGE 4722
AutoCAD SHX Text OWNER: BRYAN & PATTY BURNS PARCEL ID: 30-2S-21-42940-000-0030 OFFICIAL RECORD BOOK 3006, PAGE 300
AutoCAD SHX Text OWNER: DENNIS LEE & KIM MICHELLE DALTON PARCEL ID: 30-2S-21-42940-000-0020 OFFICIAL RECORD BOOK 3165, PAGE 4285
AutoCAD SHX Text OWNER: RICH RENTALS LLC PARCEL ID: 30-2S-21-42940-000-0010 OFFICIAL RECORD BOOK 3101, PAGE 3594
AutoCAD SHX Text OWNER: ROSALEE M WHITT C/O TRM INVESTMENTS LLC PARCEL ID: 30-2S-21-42290-000-0923 OFFICIAL RECORD BOOK 3212, PAGE 4996
AutoCAD SHX Text OWNER: RICHARD A & NANCY D MORPHIS PARCEL ID: 30-2S-21-42290-000-0922 OFFICIAL RECORD BOOK 3041, PAGE 388
AutoCAD SHX Text OWNER: THOMAS L & VIRGINIA E GRAHAM TRUSTEES OF TRUST PARCEL ID: 30-2S-21-42290-000-0924 OFFICIAL RECORD BOOK 2312, PAGE 400
AutoCAD SHX Text OWNER: TRAN HUY PARCEL ID: 30-2S-21-42290-000-0920 OFFICIAL RECORD BOOK 3082, PAGE 1078
AutoCAD SHX Text OWNER: ARTHUR H & JUDITH K SUMMERS PARCEL ID: 30-2S-21-42290-000-0852 OFFICIAL RECORD BOOK 2758, PAGE 1424
AutoCAD SHX Text OWNER: SANDPRINTS CONDO PH I-V PARCEL ID: 30-2S-21-42860-AAA-AAAA OFFICIAL RECORD BOOK 1179, PAGE 91
AutoCAD SHX Text OWNER: LARRY C DODD AS TRUSTEE OF REVOCABLE TRUST PARCEL ID: 30-2S-21-42291-000-0130 OFFICIAL RECORD BOOK 3168, PAGE 1480
AutoCAD SHX Text OWNER: JOSEPH W & MARTY J KEEFE PARCEL ID: 30-2S-21-42291-000-0120 OFFICIAL RECORD BOOK 3107, PAGE 1701
AutoCAD SHX Text OWNER: RONALD T & KAY F CLARK PARCEL ID: 30-2S-21-42291-000-0110 OFFICIAL RECORD BOOK 1578, PAGE 207
AutoCAD SHX Text OWNER: THOMAS P HANDEL II AS TRUSTEE PARCEL ID: 30-2S-21-42291-000-0100 OFFICIAL RECORD BOOK 3172, PAGE 2455
AutoCAD SHX Text OWNER: CYNTHIA C DENMAN PARCEL ID: 30-2S-21-42291-000-0090 OFFICIAL RECORD BOOK 2999, PAGE 1112
AutoCAD SHX Text OWNER: ROBERT W DAILEY REVOCABLE TRUST PARCEL ID: 30-2S-21-42291-000-0080 OFFICIAL RECORD BOOK 2197, PAGE 277
AutoCAD SHX Text OWNER: BLUE SURF TOWNHOMES PARCEL ID: 30-2S-21-42550-AAA-AAAA OFFICIAL RECORD BOOK 251, PAGE 658
AutoCAD SHX Text
BLUE SURF SUBDIVISION PLAT BOOK 5, PAGE 89
AutoCAD SHX Text
PORT OF CALL SUBDIVISION PLAT BOOK 9, PAGE 28
AutoCAD SHX Text
SANDPRINTS SUBDIVISION ORB 296, PG 748
AutoCAD SHX Text
GOVERNMENT LOT 92
AutoCAD SHX Text
"TOW AWAY ZONE PERMIT PARKING ONLY"
AutoCAD SHX Text
FRAME BOX OF ELECTRIC METERS
AutoCAD SHX Text
1-STORY FRAME STUCCO RESIDENCE FF=19.93
AutoCAD SHX Text
1-STORY FRAME STUCCO RESIDENCE FF=19.67
AutoCAD SHX Text
1-STORY FRAME STUCCO RESIDENCE FF=19.13
AutoCAD SHX Text
1-STORY FRAME STUCCO RESIDENCE FF=19.38
AutoCAD SHX Text
1-STORY FRAME STUCCO RESIDENCE FF=19.24
AutoCAD SHX Text
1-STORY FRAME STUCCO RESIDENCE FF=19.83
AutoCAD SHX Text
8' WOOD PRIVACY FENCE
AutoCAD SHX Text
EDGE OF PAVEMENT
AutoCAD SHX Text
ROCK DRIVE
AutoCAD SHX Text
BRICK PAVERS
AutoCAD SHX Text
BRICK PAVERS
AutoCAD SHX Text
3-STORY FRAME RESIDENCE FF=21.14
AutoCAD SHX Text
3-STORY FRAME RESIDENCE FF=20.08
AutoCAD SHX Text
"WARNING NATURAL GAS PIPELINE"
AutoCAD SHX Text
ROCK DRIVE
AutoCAD SHX Text
MULTIPLE
AutoCAD SHX Text
"OCEAN REEF"
AutoCAD SHX Text
10' WOOD PRIVACY FENCE
AutoCAD SHX Text
33' EASEMENT PER PB 5, PG 89
AutoCAD SHX Text
FOUND NAIL & DISK "LB 3724"
AutoCAD SHX Text
DIRECTIONAL ONLY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING DEP. 01-19-24
AutoCAD SHX Text
BUILDING DEP. 05-08-24
EX
IS
TI
N
G
-W
AY
(F U
TU
R
E 1-
W
AY
N O
R
TH
8 GOLF CART
PARKING SPACES
ELECTRIC
VEHICLE
CHARGING
STATION
PARKING
SPACES
7 GOLF CART
PARKING SPACES
EX
IS
TI
N
G
-W
AY
(F U
TU
R
E 1-
W
AY
N O
R
TH
30+/- BICYCLE
PARKING SPACES
PO
R
C H
PU
BLIC
R
ESTR
O O
M
AN
D
TR
AN
SIT
FAC
ILITY
BU
ILD
IN
G
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO BFO BFO BFO BFO BFO BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
S
S
S
S S
O H
L
O H
L
O H
L
O H
L
OHL
OHL
OHL
OHL
O H
L O
H L
O H
L O
H L
O H
L
OHL
OHL
OHL
OHL
O O O O O O O
O O
O O
O O
O O
O O
O O
O O
TT
W W
W
20" S
22" S 22"
S
20" S
20" S
20" S
20" S
15" S 22"
S
22" S
14" S
22" S
E
T
T
W L
W L
W L
W L
W L
W L
W L
W L
W L
W L
W L
W L
A
B
C
LI
EN
T
PR
O
JE
C
T
TA
SK
1 2 3 4 5O R
IG
IN
AL
R
EV
IS
IO
N
S:
D
EC
EM
BE
R
DR
IF
TW
OO
D
RD
MU
NI
CI
PA
L P
AR
KI
NG
F
AC
ILI
TY
(1
P
LA
NS
N
. M on ro e
S t.
B ui ld in g C
T al la ha ss ee
, F L
0.
5.
F
B P
R C er tif ic at e of
A ut ho riz at io n N o.
JF JF PL
T
E2
SH
EE
T
JO
B
N O
D R
AW
N
D
ES
IG
N
ED
C H
EC
KE
D
Q C
R V
PE
D
R O
L . T
R
EV
IN
FL
P E#
N
1"
0'
EL
EC
TR
IC
AL
S
IT
E
PL
AN
SCALE IN FEET
010' 20' 40'
AutoCAD SHX Text
AutoCAD SHX Text OWNER: RICH RENTALS LLC C/O PAK PROPERTIES LLC PARCEL ID: 30-2S-21-42290-000-0921 OFFICIAL RECORD BOOK 3213, PAGE 4722
AutoCAD SHX Text OWNER: BRYAN & PATTY BURNS PARCEL ID: 30-2S-21-42940-000-0030 OFFICIAL RECORD BOOK 3006, PAGE 300
AutoCAD SHX Text OWNER: DENNIS LEE & KIM MICHELLE DALTON PARCEL ID: 30-2S-21-42940-000-0020 OFFICIAL RECORD BOOK 3165, PAGE 4285
AutoCAD SHX Text OWNER: RICH RENTALS LLC PARCEL ID: 30-2S-21-42940-000-0010 OFFICIAL RECORD BOOK 3101, PAGE 3594
AutoCAD SHX Text OWNER: ROSALEE M WHITT C/O TRM INVESTMENTS LLC PARCEL ID: 30-2S-21-42290-000-0923 OFFICIAL RECORD BOOK 3212, PAGE 4996
AutoCAD SHX Text OWNER: RICHARD A & NANCY D MORPHIS PARCEL ID: 30-2S-21-42290-000-0922 OFFICIAL RECORD BOOK 3041, PAGE 388
AutoCAD SHX Text OWNER: THOMAS L & VIRGINIA E GRAHAM TRUSTEES OF TRUST PARCEL ID: 30-2S-21-42290-000-0924 OFFICIAL RECORD BOOK 2312, PAGE 400
AutoCAD SHX Text OWNER: TRAN HUY PARCEL ID: 30-2S-21-42290-000-0920 OFFICIAL RECORD BOOK 3082, PAGE 1078
AutoCAD SHX Text OWNER: ARTHUR H & JUDITH K SUMMERS PARCEL ID: 30-2S-21-42290-000-0852 OFFICIAL RECORD BOOK 2758, PAGE 1424
AutoCAD SHX Text OWNER: SANDPRINTS CONDO PH I-V PARCEL ID: 30-2S-21-42860-AAA-AAAA OFFICIAL RECORD BOOK 1179, PAGE 91
AutoCAD SHX Text OWNER: LARRY C DODD AS TRUSTEE OF REVOCABLE TRUST PARCEL ID: 30-2S-21-42291-000-0130 OFFICIAL RECORD BOOK 3168, PAGE 1480
AutoCAD SHX Text OWNER: JOSEPH W & MARTY J KEEFE PARCEL ID: 30-2S-21-42291-000-0120 OFFICIAL RECORD BOOK 3107, PAGE 1701
AutoCAD SHX Text OWNER: RONALD T & KAY F CLARK PARCEL ID: 30-2S-21-42291-000-0110 OFFICIAL RECORD BOOK 1578, PAGE 207
AutoCAD SHX Text OWNER: THOMAS P HANDEL II AS TRUSTEE PARCEL ID: 30-2S-21-42291-000-0100 OFFICIAL RECORD BOOK 3172, PAGE 2455
AutoCAD SHX Text OWNER: CYNTHIA C DENMAN PARCEL ID: 30-2S-21-42291-000-0090 OFFICIAL RECORD BOOK 2999, PAGE 1112
AutoCAD SHX Text OWNER: ROBERT W DAILEY REVOCABLE TRUST PARCEL ID: 30-2S-21-42291-000-0080 OFFICIAL RECORD BOOK 2197, PAGE 277
AutoCAD SHX Text OWNER: BLUE SURF TOWNHOMES PARCEL ID: 30-2S-21-42550-AAA-AAAA OFFICIAL RECORD BOOK 251, PAGE 658
AutoCAD SHX Text
BLUE SURF SUBDIVISION PLAT BOOK 5, PAGE 89
AutoCAD SHX Text
PORT OF CALL SUBDIVISION PLAT BOOK 9, PAGE 28
AutoCAD SHX Text
GOVERNMENT LOT 92
AutoCAD SHX Text
"TOW AWAY ZONE PERMIT PARKING ONLY"
AutoCAD SHX Text
FRAME BOX OF ELECTRIC METERS
AutoCAD SHX Text
1-STORY FRAME STUCCO RESIDENCE FF=19.93
AutoCAD SHX Text
1-STORY FRAME STUCCO RESIDENCE FF=19.67
AutoCAD SHX Text
1-STORY FRAME STUCCO RESIDENCE FF=19.13
AutoCAD SHX Text
1-STORY FRAME STUCCO RESIDENCE FF=19.38
AutoCAD SHX Text
1-STORY FRAME STUCCO RESIDENCE FF=19.24
AutoCAD SHX Text
1-STORY FRAME STUCCO RESIDENCE FF=19.83
AutoCAD SHX Text
8' WOOD PRIVACY FENCE
AutoCAD SHX Text
EDGE OF PAVEMENT
AutoCAD SHX Text
ROCK DRIVE
AutoCAD SHX Text
BRICK PAVERS
AutoCAD SHX Text
BRICK PAVERS
AutoCAD SHX Text
3-STORY FRAME RESIDENCE FF=21.14
AutoCAD SHX Text
3-STORY FRAME RESIDENCE FF=20.08
AutoCAD SHX Text
"WARNING NATURAL GAS PIPELINE"
AutoCAD SHX Text
ROCK DRIVE
AutoCAD SHX Text
MULTIPLE
AutoCAD SHX Text
"OCEAN REEF"
AutoCAD SHX Text
10' WOOD PRIVACY FENCE
AutoCAD SHX Text
33' EASEMENT PER PB 5, PG 89
AutoCAD SHX Text
FOUND NAIL & DISK "LB 3724"
AutoCAD SHX Text
DIRECTIONAL ONLY
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LP#1
AutoCAD SHX Text
LP#2
AutoCAD SHX Text
LP#3
AutoCAD SHX Text
LP#5
AutoCAD SHX Text
LP#4
AutoCAD SHX Text
LP#6
AutoCAD SHX Text
LP#7
AutoCAD SHX Text
LP#8
AutoCAD SHX Text
LP#9
AutoCAD SHX Text
LP#10
AutoCAD SHX Text
LP#12
AutoCAD SHX Text
LP#11
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PANEL P
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text P-4,6
AutoCAD SHX Text P-4,6
AutoCAD SHX Text P-4,6
AutoCAD SHX Text P-4,6
AutoCAD SHX Text P-4,6
AutoCAD SHX Text P-4,6
AutoCAD SHX Text P-4,6
AutoCAD SHX Text P-4,6
AutoCAD SHX Text P-4,6
AutoCAD SHX Text P-4,6
AutoCAD SHX Text P-4,6
AutoCAD SHX Text P-4,6
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text COORDINATE WITH LANDSCAPE PLANS FOR UNDERGROUND FEEDERS. TRENCH TO BE 24" DEEP MINIMUM. REFER TO DETAIL.
AutoCAD SHX Text
LIGHTING FIXTURE SCHEDULE FOR PARKING LOT ILLUMINATION
AutoCAD SHX Text
LAMPS
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
CATALOG NUMBER
AutoCAD SHX Text
NO
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
VOLTAGE
AutoCAD SHX Text
WATTS
AutoCAD SHX Text
MOUNTING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LITHONIA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
POLE MOUNTED WITH SQUARE
AutoCAD SHX Text
OR ROUND ADAPTER
AutoCAD SHX Text
AutoCAD SHX Text
LED
AutoCAD SHX Text
AutoCAD SHX Text PANEL P AND LIGHTING CONTROL. FOR MORE INFORMATION, REFER TO ELECTRICAL PLAN DONE BY HG Engineers, SHEET E3.1.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DSX2 LED P4 AMBLW T3M 240 RPA**
AutoCAD SHX Text
KEYED NOTES
AutoCAD SHX Text
PULL BOX AT EACH LIGHTING POLE. REFER TO DETAIL IN SHEET E100.
AutoCAD SHX Text
* OR APPROVED EQUALOR APPROVED EQUAL
AutoCAD SHX Text
** RPA FOR: ROUND POLE MOUNTEDRPA FOR: ROUND POLE MOUNTED
AutoCAD SHX Text
2#10 THWN CU & 1#10 THWN CU GND IN 1" CONDUIT.
AutoCAD SHX Text
DAMP LOCATION RATED, LED LUMINAIRE, TYPE III MH =24 FT
AutoCAD SHX Text
AutoCAD SHX Text SETTING FOR BACKLIGHT TO BE IN MINIMUM VALUE, REFER TO MANUFACTURER SPECIFICATIONS.
AutoCAD SHX Text
LITHONIA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
POLE MOUNTED WITH SQUARE
AutoCAD SHX Text
OR ROUND ADAPTER
AutoCAD SHX Text
AutoCAD SHX Text
LED
AutoCAD SHX Text
DAMP LOCATION RATED, LED LUMINAIRE, TYPE III MH =24 FT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text NOTE FOR FIXTURE TYP C: "BLC": Backlight Control to set up to "minimum" level and "EGS": Option to be ordered for External Glare Shield.
AutoCAD SHX Text
DSX2 LED P4 AMBLW T3M 240 BLC-EGS RPA**
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING DEP. 01-19-24
AutoCAD SHX Text
BUILDING DEP. 05-08-24
| E100 |
| Sheets and Views |
| E100 |
| E200 |
| Sheets and Views |
| E200 |
| E201 |
| Sheets and Views |
| E201 |
| 2024-05-31T16:19:57-0400 | |
| Pedro L Trevin |
| 2024-05-31T16:20:40-0400 | |
| Pedro L Trevin |
| 2024-05-31T16:21:17-0400 | |
| Pedro L Trevin |
File details come from the government source that posted it. Updated .