a._Architectural-21014-DriftwoodTransitBldg-SS.pdf
PDF 2 MB Posted
- Attached to
- Driftwood Road Municipal Parking Facility
- Solicitation number
- ITB 24-34
- Issued by
- Walton County, Florida
About this file
The document is an architectural plan set for the Driftwood Transit Stop & Restroom project located at 79 Driftwood Road in Miramar Beach, Walton County, Florida, prepared by Stokes Architectural, Inc. The comprehensive set of architectural drawings includes detailed plans for a small transit facility and public restroom building, with drawings covering floor plans, elevations, roof details, signage, wall sections, and specifications for construction. The project involves constructing a single-story building with men's and women's restroom facilities, an electrical room, janitor's closet, and waiting area, totaling approximately 1,011 square feet. The drawings are dated May 20, 2024, and follow the Florida Building Code 2023 Edition, with specific attention to accessibility, building materials, and construction standards.
The architectural plans specify construction type as Type I-A, with a building height of 16'-11 1/4" and one story. The project includes detailed specifications for materials including fiber-cement siding, vinyl windows, fiberglass doors, epoxy flooring, and various architectural finishes. Structural requirements include wood framing, thermal insulation, air infiltration barriers, and specific installation guidelines for each building component. The specifications outline rigorous standards for material quality, installation techniques, and compliance with local building codes, accessibility requirements, and environmental considerations. The project appears to be a municipal infrastructure improvement focused on providing public transit and restroom facilities with emphasis on durability, accessibility, and functional design.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A-001
GENERAL INFORMATION
A-100 Floor Plan
A-150 Schedules / Partition Types / Details
A-200 Exterior Elevations / Details
A-400 Roof Plan / Details
Architectural
A-250 Building Sections / Wall Section
General NotesStandard Abbreviations
INTERPRETATION OF THESE CONSTRUCTION DOCUMENTS.
ELECTRICAL, PLUMBING AND TELEPHONE/COMMUNICATION EQUIPMENT.
ATION OF BUILDING SYSTEM EQUIPMENT AND VERIFY THAT THE
THE EQUIPMENT. PROVIDE ALL ASSOCIATED WORK WHICH INCLUDES,
J.) THE CONTRACTOR SHALL COORDINATE THE LOCATION AND INSTALL-
BUT IS NOT LIMITED TO, THE FOLLOWING SYSTEMS: MECHANICAL,
REQUIRED CLEARANCES FOR INSTALLATION AND MAINTENANCE OF
E.) THE ARCHITECT IS SOLELY RESPONSIBLE FOR THE DESIGN AND
D.) DRAWINGS MAY NOT ALWAYS BE TO SCALE. NOTED DIMENSIONS MAY
G.) THE CONTRACTOR SHALL PROVIDE ADEQUATE DESIGN AND
RESPONSIBLE FOR ALL CONDITIONS OF THE JOB SITE AT ALL TIMES
F.) THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY
THESE SHALL REMAIN IN PLACE, UNTIL ALL ELEMENTS OF THE DESIGN
CONSTRUCTION OF ALL FORMS, BRACING, AND SHORING AS REQUIRED.
SOMETIMES TAKE PRECEDENCE. DIMENSIONS ARE NOT ADJUSTABLE
INCLUDING THE SAFETY OF PERSONS AND PROPERTY.
HAVE BEEN INCORPORATED INTO THE PROJECT.
EXISTING SITE CONDITIONS, AND ANY OTHER RELATED ITEMS
A.) THE CONTRACTOR SHALL PROVIDE ALL MATERIALS, EQUIPMENT,
LABOR AND OTHER NECESSARY ITEMS FOR THE COMPLETION OF
B.) ALL MATERIAL WORKMANSHIP SHALL CONFORM TO THE LATEST UBC,
NEC, UPC, UFC, OSHA, ALL LOCAL BUILDING CODES, AND ANY OTHER
C.) THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, NOTES, DETAILS,
PERTAINING TO THIS PROJECT AND REPORT ANY ERRORS,
TO PROCEEDING WITH ANY WORK OR MATERIAL PURCHASES.
IF CONFLICTS ARE FOUND, THE MOST STRINGENT CONDITIONS SHALL
GOVERN UNLESS SPECIFIC WRITTEN NOTIFICATION BY THE ARCHITECT.
WORK DESCRIBED ON THESE DRAWINGS.
CONSTRUCTION INDUSTRY STANDARDS.
INCONSISTENCIES, AND / OR OMISSIONS TO THE ARCHITECT, PRIOR
UNLESS NOTED WITH A PLUS /MINUS SYMBOL (+/-).
H.) THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING
BE SOLELY RESPONSIBLE FOR AND HAVE CONTROL OVER ALL
HIS BEST SKILL AND UNDIVIDED ATTENTION. THE CONTRACTOR SHALL
CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND
PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK
UNDER THE CONTRACT, UNLESS CONTRACT DOCUMENTS GIVE OTHER
SPECIFIC INSTRUCTIONS CONCERNING THESE MATTERS.
REPORT THE CONDITION TO THE OWNER IN WRITING.
POLYCHLORINATED BIPHENYL (PCB) OR OTHER TOXIC MATERIAL
SHALL IMMEDIATELY STOP WORK IN THE AREA AFFECTED AND
WHICH HAS NOT BEEN RENDERED HARMLESS, THE CONTRACTOR
SITE THAT ARE REASONABLY BELIEVED TO BE ASBESTOS,
Q.) IN THE EVENT THE CONTRACTOR ENCOUNTERS MATERIALS ON THE
P.) FIRE EXTINGUISHER, ELECTRICAL PANELS, TELEPHONE EQUIPMENT
PANELS AND/OR EQUIPMENT SHALL BE SURFACE MOUNTED AND
TO ROUGH-IN INSTALLATION. UNLESS OTHERWISE NOTED, THE ABOVE
LOCATIONS NOT SHOWN SHALL BE VERIFIED WITH ARCHITECT PRIOR
MAINTAIN THE INTEGRITY OF WALL FIRE RATING REQUIREMENTS.
BOARDS, ETC., SHALL BE LOCATED IN ACCORDANCE WITH
REQUIREMENTS SET BY THE GOVERNING AGENCIES. ANY
INCLUDING: PAINT, TRIM, MILLWORK, FLOORING, CEILING AND WALL
O.) THE CONTRACTOR SHALL VERIFY ALL FINISHES WITH OWNER / TENANT
COVERINGS.
NOT BE INSTALLED INTO THE WORK. ANY INSTALLED MATERIALS
AND AFTER INSTALLATION. WET, MOIST, OR DAMP MATERIALS SHALL
SHALL BE PROTECTED FROM SUCH CONTAMINANTS BEFORE, DURING,
BACTERIA, AND OTHER SUCH ORGANIC CONTAMINANTS. MATERIALS
L.) ALL MATERIALS AND CONSTRUCTION SHALL BE FREE OF MOLDS,
AND/OR REMOVED FROM THE WORK.
CONTAINING SUCH MOISTURE OR CONTAMINANTS SHALL BE REPLACED
CONTRACTOR SHALL SECURE AND PAY FOR BUILDING PERMITS AND
K.) UNLESS OTHERWISE PROVIDED IN THE CONTRACT DOCUMENTS, THE
ORDINANCES, RULES AND REGULATIONS, AND LAWFUL ORDERS OF
SHALL COMPLY WITH AND GIVE NOTICES REQUIRED BY LAWS,
OF THE WORK DESCRIBED IN THESE DOCUMENTS. THE CONTRACTOR
ANY OTHER PERMITS AND GOVERNMENTAL FEES, LICENSES AND
PUBLIC AUTHORITIES BEARING ON PERFORMANCE OF THE WORK.
INSPECTIONS NECESSARY FOR PROPER EXECUTION AND COMPLETION
N.) THE CONTRACTOR IS RESPONSIBLE TO PREPARE THE BUILDING FOR
BY THE CONTRACT WORK FROM THE PROPERTY AS IT ACCUMULATES.
M.) THE CONTRACTOR IS RESPONSIBLE TO REMOVE ALL DEBRIS CAUSED
OCCUPANCY WITH A THOROUGH CLEANING THROUGHOUT.
INCH
JOINT
INTERIOR
ID
IN
JT
INT
INSUL
AE
AD
ACT
AFF
AHU
ARCHITECT(URAL)
AREA DRAIN
ACOUSTICAL TILE
AT
AIR HANDLING UNIT
ABOVE FINISHED FLOOR
ARCHITECT-ENGINEER
MAXIMUM
MINIMUM
METAL
MAX
MTL
MIN
MISC
MFR
MECH
NORTH
NOMINAL
NUMBER
N
NA
NIC
NOM
NTS
NO
BD
BIT
BLDG
BM
BRG
BTM
BLKG
BLK
BEARING
BOTTOM
BEAM
BLOCKING
BLOCK
BUILDING
BITUMINOUS
BOARD
CEM PL
BUR
BRK
CJ
CHEM
CFCI
CEMENT PLASTER
BUILT UP ROOFING
BRICK
CHEMICAL
CONTROL JOINT/
CONTRACTOR FURNISHED
CONTRACTOR INSTALLED
OVERHEAD
OFCI
OD
OFOI
OH
OFCRI
PLATE
OPPOSITE
PAIR
OPP
PL
PR
PT
QT
PLAM
OPH
CL
CLG
COL
CMU
CONF
CPT
CONT
CONC
CENTER LINE
CONFERENCE
CARPET(ED)
CONTINUE(OUS)
CONCRETE
COLUMN
CEILING
DET
DF
DEMO
DIM
DIA
DN
DIV
DOWN
DIVISION
DIMENSION
DIAMETER
DETAIL
DEMOLISH(TION)
CERAMIC TILECT
CONCRETE MASONRY UNIT
DRINKING FOUNTAIN
OC
CONSTRUCTION JOINT
INSIDE DIAMETER
INSULATE(D)(ION)
MECHANIC(AL)
MANUFACTURE(R)
MISCELLANEOUS
NOT APPLICABLE
NOT IN CONTRACT
NOT TO SCALE
ON CENTER(S)
OUTSIDE DIAMETER
OPPOSITE HAND
QUARRY TILE
PRESSURE TREATED
PLASTIC LAMINATE
OWNER FURNISHED
CONTRACTOR INSTALLED
OWNER FURNISHED
OWNER INSTALLED
OWNER FURNISHED
CONTRACTOR ROUGH IN
RECESSED
RESILIENT
REQUIRED
R
RD
REC
REQ
REV
RES
REINF
SOUTH
SQUARE
SECTION
SIMILAR
RO
S
SC
SECT
SIM
SQ
SPEC
RM ROOM
E
DWG
EJ
EL
ELEV
ELEC
EA
DRAWING(S)
ELEVATOR
ELECTRIC(AL)
ELEVATION
EXPANSION JOINT
EACH
EAST
EQ
EQUIP
EXIST
EWC
EXT
FDN
EXP
EQUIPMENT
FOUNDATION
EXTERIOR
EXPOSED
EXISTING
EQUAL
ELECTRIC WATER COOLER
SYSTEM
TYPICAL
TOP OF
TREAD
SYS
THK
TO
TYP
T
STRUCT
UNDERCUT
VERTICAL
UL
UC
UNO
VERT
VWC
VTR
VCT
FEC
FF
FIN
FHC
FL
FT
FO
FIXT
FLOOR
FOOT/FEET
FACE OF
FIXTURE
FINISH(ED)
FINISHED FLOOR
GL
GA
GALV
GYP
HA
GWB
GYPSUM
GLASS/GLAZING
GALVANIZED
GAGE/GAUGE
FOOTINGFTG
FIRE EXTINGUISHER CABINET
HANDICAP ACCESSIBLE
GYPSUM WALL BOARD
FIRE HOSE CABINET
FIRE EXTINGUISHERFE
SS
WITHOUT
WITH
W
W/0
WPT
W/
HM
HT
HR
HVAC
HOLLOW METAL
AIR CONDITIONING
HEIGHT/HIGH
HOUR
HEATING, VENTILATING AND
HARDWAREHDW
ROOF DRAIN
REINFORCE(D)(ING)
WORK POINT
WEST/WIDTH
VINYL COMPOSITION TILE
VENT THRU ROOF
VINYL WALL COVERING
UNLESS NOTED OTHERWISE
UNDERWRITERS LABORATORY
THICK(NESS)
STRUCTURAL
SOLID CORE
SPECIFICATION(S)
STAINLESS STEEL
ROUGH OPENING
REVISE(SION)(D)
RISER/RADIUS
DOORDR
MT METAL THRESHOLD
TACK BOARDTB
MARKER BOARDMB
A/C AIR CONDITIONING
AB ANCHOR BOLT
ARCH
APPX APPROXIMATE
ALUM ALUMINUM
ABV ABOVE
ADJ ADJACENT
ALT ALTERNATE
BR BACKER ROD
BTW BETWEEN
B/W BOTH WAYS
CABINETCAB
CEMENTCEM
CUBIC FEETCF
CAST IN PLACECIP
CIRCLECIR
CENTER LINEC/L
CLOSETCLOS
CLEAR(ANCE)CLR
CONCRETE MASONRY UNITCMU
CARPETCPT
COUNTERCTR
DISP DISPENSER
D/W DISH WASHER
EP ELECTRICAL PANEL
ES EACH SIDE
EST ESTIMATE
EXH EXHAUST
FIRE ALARMFA
FLOOR DRAINFD
FFE FINISHED FLOOR ELEVATION
FLOOR (ING)FLR
GB GRAB BAR
GC GENERAL CONTRACT (OR)
JANITORJAN
JOISTJST
KITCHENKIT
LENGTHL
LAVATORYLAV
LF LINEAL FEET
LAM LAMINATED
LBS POUND (S)
MAS MASONRY
MED MEDIUM
MO MASONRY OPENING
MR MOISTURE RESISTANT
PARA PARALLEL
PB PANIC BAR
PED PEDESTAL
PSI
POUNDS PER SQUARE INCH
PWD PLYWOOD
PVC POLYVINYL CHLORIDE
RA RETURN AIR
REF REFRIGERATOR
REG REGISTER
ROW RIGHT OF WAY
SPLASH BLOCKSB
HB HOSE BIBB
STEELSTL
SCHEDULESCH
TOP OF PLATETOP
TONGUE AND GROOVET&G
TEMPERED GLASSTG
TOLERANCETOL
TELEVISIONTV
UR URINAL
UNF UNFINISHED
WB WOOD BASE
WWF WELDED WIRE FABRIC
WR WATER REPELLENT
WM WIRE MESH
W/H WATER HEATER
WD WOOD
WC WATER CLOSET
WA WASHER
WDT WIDTH, WIDE
WG WIRE GLASS
INSPECTIONS WITH LOCAL AUTHORITIES HAVING JURISDICTION.
R.) THE CONTRACTOR SHALL COORDINATE AND SCHEDULE REQUIRED
A-300 Interior elevations
NOTE:
CONTRACTOR TO SUBMIT ALL FLORIDA PRODUCT APPROVAL CODES
RELATED TO THE EXTERIOR BUILDING ENVELOPE FOR PERMITTING.
A-500 Specifications
Applicable Code: New Construction Renovation (Existing Building)
Building Data:
Construction Type: I-A I-B II-A II-B III-A III-B IV V-A V-B
Mixed Construction: Yes No Type:
Sprinklers: No Yes
Protected: No Yes
Fire District: No Yes
Building Height: 16'-11 1/4" 1 Number of Stories
NFPA 13
I
NFPA 13R NFPA 13D
ii iii Wet Dry
Unlimited Per
Mezzanine: No Yes
High Rise: No Yes
Building Areas:
Floor: New (Sq. Ft.)
Total Sq. Ft. 1,011 Sq. Ft.
A-001 General Information
A-101 Reflected Ceiling Plan / Floor Finish Plan / Details
A-501 Specifications
A-502 Specifications
A-503 Specifications
Occupancy:
Primary Occupancy: Assembly
Business
High-Hazard
Institutional
Mercantile
Storage
Utility and Miscellaneous
A-1
Educational
H-1
I-1
I-1 Use Condition
S-1
Residential
A-2
Factory -Industrial
H-2
I-2
S-2
R-1
Parking Garage
A-3
H-3
I-3
High-Filled
R-2
A-4
H-4
I-4
R-3
Open Enclosed
F-1
A-5
H-5
R-4
Repair
F-2
Mixed Occupancy: No
S-501
Structural
S-101 Structural Framing Plans
S-001 Structural Design Notes
S-502 Construction Details
Plumbing
P-002 Plumbing Schedules & Details
P-001 Plumbing Legend & Notes
Mechanical
M-002 Mechanical Schedules & Details
M-001 Mechanical Legend & Notes
E2.1 Floor Plan - Electrical
Electrical
E1.1 Site Plan - Electrical
E0.1 Legend & Notes
E3.1
E3.2
Electrical Details
Power Riser & Grounding Details
P-101 Plumbing Plan & Details
M-101 Mechanical Plan & Details
Construction Details
5/20/2024
DRAWING NUMBER:
DATE: FILE:
SHEET TITLE:
APPROVED BY:
REVISIONS:
21014
St o ke s
A rc hi te c tu ra l, In c
St o ke s
A rc hi te c tu ra l, in c
. h e re b y e xp re ss ly re se rv e s its c o m m o n-la w c o p yr ig ht a nd o th e r p ro p e rty ri g ht s to th e se p la ns
D ra w in g s a re n o t t o b e re p ro d uc e d , c ha ng e d
, o r c o p ie d in a ny fo rm w ha ts o e ve r, no r a re th e y to b e a ss ig ne d to a ny th ird p a rty w ith o ut fi rs t o b ta in in g th e e xp re ss w rit te n p e rm is si o n a nd c o ns e nt o f S to ke s A rc hi te c tu ra l, in c
DRAWN BY:
CG
CHECKED BY:
CG
A rc hi te c tu re
M a st e r P la nn in g
In te rio r D e si g n
C lo ve rd a le
B o ul e va rd
Fo rt
W a lto n
Be a c h, F lo rid a
Ph o ne
0)
-2
F x:
(8
) 6
-6
F L
L i c e n s e
A
R
L
C o r p
L i c e n s e
A
A C
Architectural Inc.
Stokes
M ir a m a r
B ea ch
Fl o ri d a
Drift woo d Tr ansi t Sto p &
Rest room
- W alto n Co unty
D ri ft w o o d R o a d
PROFESSIONAL SEAL:
AR009663005/20/2024
Florida Building Code 2023 Edition
Florida Plumbing Code 2023 Edition
Florida Mechanical Code 2023 Edition
2020 NFPA 70 National Electrical Code
NFPA 101, Life Safety Code 2021 Edition
Florida Fire Prevention Code 7th Edition 2023
AutoCAD SHX Text
AR96630
Floor Plan Legend
N
SCALE: 1/2" = 1'-0"
Enlarged Plan2
A-100
Requirements
Accessible Fixture
A
B
C
D A-300
Square FootageKey NotesSignage Placement
Sign Types
Waiting
Area
Porch
Men
Women
Chase
Janitor
Elec
A-100
A-250
A-250
A-250
Toilet Room Accessory Schedule
SCALE: 1/4" = 1'-0"
Floor Plan1
A-100
Men
Women
Chase 106Janitor
Elec
A
A-300
A
A-300
FLOOR PLAN
A-100
5/20/2024
DRAWING NUMBER:
DATE: FILE:
SHEET TITLE:
APPROVED BY:
REVISIONS:
21014
St o ke s
A rc hi te c tu ra l, In c
St o ke s
A rc hi te c tu ra l, in c
. h e re b y e xp re ss ly re se rv e s its c o m m o n-la w c o p yr ig ht a nd o th e r p ro p e rty ri g ht s to th e se p la ns
D ra w in g s a re n o t t o b e re p ro d uc e d , c ha ng e d
, o r c o p ie d in a ny fo rm w ha ts o e ve r, no r a re th e y to b e a ss ig ne d to a ny th ird p a rty w ith o ut fi rs t o b ta in in g th e e xp re ss w rit te n p e rm is si o n a nd c o ns e nt o f S to ke s A rc hi te c tu ra l, in c
DRAWN BY:
CG
CHECKED BY:
CG
A rc hi te c st e r P la nn rio r D e si g n
C lo ve rd a le
B o ul e va rd
Fo rt
W a lto n
Be a c h, F lo rid a
Ph o ne
0)
-2 x:
(8
) 6
-6
F L
L i c e n s e
A
R
C o r p
L i c e n s e
A
A C
Architectural Inc.
Stokes
M ir a m a r
B ea ch
Fl o ri d a
Drift woo d Tr ansi t Sto p &
Rest room
- W alto n Co unty
D ri ft w o o d R o a d
PROFESSIONAL SEAL:
AR009663005/20/2024
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
LAVATORY RIM HEIGHT
AutoCAD SHX Text
HLAV
AutoCAD SHX Text
MARK
AutoCAD SHX Text
MOUNT 34" A.F.F.
AutoCAD SHX Text
PLACEMENT
AutoCAD SHX Text
TOILET - SEAT HEIGHT
AutoCAD SHX Text
WC
AutoCAD SHX Text
MOUNT 17"-19" A.F.F.
AutoCAD SHX Text
URINAL
AutoCAD SHX Text
UR
AutoCAD SHX Text
MOUNT 17" A.F.F.
AutoCAD SHX Text
REFERENCE ELEVATION HEIGHT
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text
SEE DOOR SCHEDULE
AutoCAD SHX Text
SEE LOUVER SCHEDULE
AutoCAD SHX Text
SEE FINISH SCHEDULE
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
SEE PARTITION TYPES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WAITING AREA
AutoCAD SHX Text
PORCH
AutoCAD SHX Text
317 SQ. FT.
AutoCAD SHX Text
INTERIOR ELEVATIONS
AutoCAD SHX Text
245 SQ. FT.
AutoCAD SHX Text
TOTAL AREA
AutoCAD SHX Text
1,023 FT.
AutoCAD SHX Text
ROOM NAME
AutoCAD SHX Text
SQ. FT.
AutoCAD SHX Text
ROOM #
AutoCAD SHX Text
WALL
AutoCAD SHX Text
UNDER COUNTER - HOSE BIBB
AutoCAD SHX Text
1/2" EXPANSION JOINT, TYPICAL AROUND BUILDING PERIMETER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text W1
AutoCAD SHX Text
CONTROL JOINT
AutoCAD SHX Text
AutoCAD SHX Text
WOMENS RESTROOM SIGN
AutoCAD SHX Text
AutoCAD SHX Text
MENS RESTROOM SIGN
AutoCAD SHX Text
AutoCAD SHX Text
SOLID PLASTIC TOILET PARTITION
AutoCAD SHX Text
AutoCAD SHX Text w/ ADA COMPLIANT DOOR (32" CLEAR)
AutoCAD SHX Text
SOLID PLASTIC TOILET PARTITION
AutoCAD SHX Text
AutoCAD SHX Text w/ 24" DOOR
AutoCAD SHX Text
HI-LO WATER FOUNTAIN - ADA COMPLIANT (LOW SPOUT
AutoCAD SHX Text
AutoCAD SHX Text
HEIGHT 36" MAX.)
AutoCAD SHX Text
AutoCAD SHX Text
SEE KEY NOTES
AutoCAD SHX Text
AutoCAD SHX Text
RESTROOM
AutoCAD SHX Text
RESTROOM
AutoCAD SHX Text
ROOM NAME
AutoCAD SHX Text
BRAILLE
AutoCAD SHX Text
SYMBOLS
AutoCAD SHX Text
(AS REQUIRED)
AutoCAD SHX Text
TYPICAL SIGN MOUNT HEIGHTS. SIGNS
AutoCAD SHX Text
TO BE LOCATED ON LATCH SIDE
AutoCAD SHX Text
OF DOOR & 8" OUT OF DOOR SWING.
AutoCAD SHX Text
SOAP DISPENSER
AutoCAD SHX Text
SD
AutoCAD SHX Text
MOUNT 48" A.F.F.
AutoCAD SHX Text
TOTAL ENCLOSED AREA
AutoCAD SHX Text
778 SQ. FT.
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text
MOP SINK
AutoCAD SHX Text
MS
AutoCAD SHX Text
FLOOR MOUNT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MEN
AutoCAD SHX Text
135 SQ. FT.
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text
141 SQ. FT.
AutoCAD SHX Text
AutoCAD SHX Text
JANITOR
AutoCAD SHX Text
34 SQ. FT.
AutoCAD SHX Text
AutoCAD SHX Text
CHASE
AutoCAD SHX Text
33 SQ. FT.
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
20 SQ. FT.
AutoCAD SHX Text
WALL AREA
AutoCAD SHX Text
98 SQ. FT.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text
ALL WALLS UNLESS OTHERWISE NOTED
AutoCAD SHX Text W1
AutoCAD SHX Text
MOUNT 34" A.F.F. TO C
AutoCAD SHX Text
MOUNT 34" A.F.F. TO C
AutoCAD SHX Text
MOUNT 40" A.F.F.
AutoCAD SHX Text
NO.
AutoCAD SHX Text
GRAB BAR
AutoCAD SHX Text
GRAB BAR
AutoCAD SHX Text
HAND DRYER
AutoCAD SHX Text
MIRROR
AutoCAD SHX Text A
AutoCAD SHX Text
TOILET TISSUE DISPENSER
AutoCAD SHX Text
3'-0" LONG -
AutoCAD SHX Text
3'-6" LONG -
AutoCAD SHX Text
WALL MOUNTED -
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
NOTES
AutoCAD SHX Text L
AutoCAD SHX Text L
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
WORLD DRYER
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text
WALL MOUNTED - MOUNT 46" A.F.F.
AutoCAD SHX Text
MODEL
AutoCAD SHX Text B-680636
AutoCAD SHX Text B-680642
AutoCAD SHX Text B-293 1836
AutoCAD SHX Text
WA126
AutoCAD SHX Text B-2890
AutoCAD SHX Text
BABY CHANGING STATION
AutoCAD SHX Text
KOALA BEAR KARE
AutoCAD SHX Text
KB100
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text
SANITARY NAPKIN DISPOSAL
AutoCAD SHX Text B-5270
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text
TRASH RECEPTACLE
AutoCAD SHX Text
MOP / BROOM HOLDER
AutoCAD SHX Text B-223
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text B-5277
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text J
AutoCAD SHX Text
MOUNT 40" A.F.F.
AutoCAD SHX Text
MIRROR
AutoCAD SHX Text
WALL MOUNTED -
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text B-165 1830
AutoCAD SHX Text
MOUNT 34" TO TOP OF CHANGING SURFACE A.F.F.
AutoCAD SHX Text
WALL MOUNTED -
AutoCAD SHX Text
WALL MOUNTED - MOUNT 19" A.F.F.
AutoCAD SHX Text
WALL MOUNTED - MOUNT 19" A.F.F.
AutoCAD SHX Text
COAT HOOK
AutoCAD SHX Text B-212
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text K
AutoCAD SHX Text
WALL MOUNTED - MOUNT 28" A.F.F.
AutoCAD SHX Text
WALL MOUNTED - MOUNT 48" A.F.F.
AutoCAD SHX Text
WALL MOUNTED - MOUNT 48" @ HC STALL, 60" ELSEWHERE A.F.F.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SOUND BATT INSULATION
AutoCAD SHX Text
NOTE: R-19 BATT INSULATION ALL EXTERIOR WALLS
AutoCAD SHX Text
HLAV
AutoCAD SHX Text
HLAV
AutoCAD SHX Text
HLAV
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
BCS
AutoCAD SHX Text
WC
AutoCAD SHX Text
WC
AutoCAD SHX Text
WC
AutoCAD SHX Text
GB
AutoCAD SHX Text
TTD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
UR
AutoCAD SHX Text
TR
AutoCAD SHX Text
TR
AutoCAD SHX Text
MS
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text 30" x 48" CLEAR
AutoCAD SHX Text
FLOOR SPACE
AutoCAD SHX Text
FOR LAVATORY
AutoCAD SHX Text 60" x 56" CLEAR
AutoCAD SHX Text
FLOOR SPACE
AutoCAD SHX Text
FOR TOILET
AutoCAD SHX Text 60" x 56" CLEAR
AutoCAD SHX Text
FLOOR SPACE
AutoCAD SHX Text
FOR TOILET
AutoCAD SHX Text 30" x 48" CLEAR
AutoCAD SHX Text
FLOOR SPACE
AutoCAD SHX Text
FOR LAVATORY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MIN.
AutoCAD SHX Text
MIN.
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
STOOP
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
STOOP
AutoCAD SHX Text W3
AutoCAD SHX Text W4
AutoCAD SHX Text W2
AutoCAD SHX Text W2
AutoCAD SHX Text W2
AutoCAD SHX Text W2
AutoCAD SHX Text W2
AutoCAD SHX Text W2
AutoCAD SHX Text W2
AutoCAD SHX Text W2
AutoCAD SHX Text T.O.W 8'-0"
AutoCAD SHX Text T.O.W 8'-0"
AutoCAD SHX Text T.O.W 8'-0"
AutoCAD SHX Text T.O.W 8'-0"
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text F
AutoCAD SHX Text D
AutoCAD SHX Text G
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text H
AutoCAD SHX Text J
AutoCAD SHX Text K
AutoCAD SHX Text K
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text G
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text F
AutoCAD SHX Text K
AutoCAD SHX Text D
SCALE: 1/4" = 1'-0"
Reflected Ceiling Plan1
A-101 SCALE: 1/4" = 1'-0"
Floor Finish Plan3
A-101
Floor Plan Legend
Reflected Ceiling Plan Legend
Floor Finish Legend
Waiting
Area
Porch
Men
Women
Chase
Janitor
Elec
Waiting
Area
Porch
Men
Women
Chase
Janitor
Elec
A-101
REFLECTED CEILING /
FLOOR FINISH PLANS
5/20/2024
DRAWING NUMBER:
DATE: FILE:
SHEET TITLE:
APPROVED BY:
REVISIONS:
21014
St o ke s
A rc hi te c tu ra l, In c
St o ke s
A rc hi te c tu ra l, in c
. h e re b y e xp re ss ly re se rv e s its c o m m o n-la w c o p yr ig ht a nd o th e r p ro p e rty ri g ht s to th e se p la ns
D ra w in g s a re n o t t o b e re p ro d uc e d , c ha ng e d
, o r c o p ie d in a ny fo rm w ha ts o e ve r, no r a re th e y to b e a ss ig ne d to a ny th ird p a rty w ith o ut fi rs t o b ta in in g th e e xp re ss w rit te n p e rm is si o n a nd c o ns e nt o f S to ke s A rc hi te c tu ra l, in c
DRAWN BY:
CG
CHECKED BY:
CG
A rc hi te c st e r P la nn rio r D e si g n
C lo ve rd a le
B o ul e va rd
Fo rt
W a lto n
Be a c h, F lo rid a
Ph o ne
0)
-2 x:
(8
) 6
-6 i c e n s e
A
R
C o r p
L i c e n s e
A
A C
Architectural Inc.
Stokes
M ir a m a r
B ea ch
Fl o ri d a
Drift woo d Tr ansi t Sto p &
Rest room
- W alto n Co unty
D ri ft w o o d R o a d
PROFESSIONAL SEAL:
AR009663005/20/2024
AutoCAD SHX Text
FINISHED FLOOR ELEVATION
AutoCAD SHX Text
EPOXY FLOORING - 593; SQ. FT.
AutoCAD SHX Text
SEALED CONCRETE - 677; SQ. FT.
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text
WALLS TO UNDERSIDE OF STRUCTURE
AutoCAD SHX Text 1 x 4 T&G PINE - STAINED W/ EXPOSED BEAMS
AutoCAD SHX Text
OPEN TO STRUCTURE
AutoCAD SHX Text
(APPLY TO BOTTOM OF RAFTER)
AutoCAD SHX Text
(APPLY TO TOP OF RAFTER)
AutoCAD SHX Text EXPOSED RAFTER TAILS W/ 1 x 4 T&G PINE - PAINTED
AutoCAD SHX Text
(SLIP/CHEMICAL RESISTANT FINISH)
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text 1/8":12"
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text 1/8":12"
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text 1/8":12"
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text 12'-2"
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
EF
AutoCAD SHX Text
EF
AutoCAD SHX Text
EF
AutoCAD SHX Text
EF
AutoCAD SHX Text
SURFACE MOUNTED VANDAL RESISTANT FLUORESCENT
AutoCAD SHX Text
LIGHTING FIXTURE (SEE ELECTRICAL DWGS.)
AutoCAD SHX Text
SURFACE MOUNTED FLUORESCENT
AutoCAD SHX Text
LIGHTING FIXTURE (SEE ELECTRICAL DWGS.)
AutoCAD SHX Text
EF
AutoCAD SHX Text
SURFACE MOUNTED WATER PROOF EXTERIOR
AutoCAD SHX Text
LIGHTING FIXTURE (SEE ELECTRICAL DWGS.)
AutoCAD SHX Text
LED EXIT SIGN, WITH EMERGENCY LIGHT & INTEGRAL
AutoCAD SHX Text
BATTERY (SEE ELECTRICAL DWGS.)
AutoCAD SHX Text
CEILING MOUNTED EXHAUST FAN - COORDINATE LOCATION
AutoCAD SHX Text
WITH MECHANICAL. (SEE ELECTRICAL DWGS.)
AutoCAD SHX Text
HTR
AutoCAD SHX Text
SURFACE MOUNTED UNIT HEATER - COORDINATE LOCATION
AutoCAD SHX Text
WITH MECHANICAL. (SEE ELECTRICAL DWGS.)
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text 1/8":12"
AutoCAD SHX Text
NOTE: CONTRACTOR TO VERIFY ALL FLOORING SQUARE FOOTAGES
AutoCAD SHX Text
EPOXY FLOORING
AutoCAD SHX Text %%uENTRANCE
AutoCAD SHX Text
CONCRETE WALKWAY
AutoCAD SHX Text
1/2" EXPANSION
AutoCAD SHX Text
JOINT
AutoCAD SHX Text
CONCRETE SLAB
AutoCAD SHX Text
(SLIP/CHEMICAL
AutoCAD SHX Text
RESISTANT FINISH)
HARDWARE SET #2HARDWARE SET #1
Door Elevations
Partition Types
Door Frame Elevations
Room Finish Schedule
Door Schedule
Hardware Schedule
Window Elevations
W-1 W-2 W-3 W-4
W i n d o w S c h e d u l e
SCALE: 3"=1'-0"
Threshold Detail1
A-150
SCALE: 3"=1'-0"
Jamb Detail2
A-150
A-150 SCALE: 3"=1'-0"
Head Detail
SCHEDULES /
A-150
DETAILS
5/20/2024
DRAWING NUMBER:
DATE: FILE:
SHEET TITLE:
APPROVED BY:
REVISIONS:
21014
St o ke s
A rc hi te c tu ra l, In c
St o ke s
A rc hi te c tu ra l, in c
. h e re b y e xp re ss ly re se rv e s its c o m m o n-la w c o p yr ig ht a nd o th e r p ro p e rty ri g ht s to th e se p la ns
D ra w in g s a re n o t t o b e re p ro d uc e d , c ha ng e d
, o r c o p ie d in a ny fo rm w ha ts o e ve r, no r a re th e y to b e a ss ig ne d to a ny th ird p a rty w ith o ut fi rs t o b ta in in g th e e xp re ss w rit te n p e rm is si o n a nd c o ns e nt o f S to ke s A rc hi te c tu ra l, in c
DRAWN BY:
CG
CHECKED BY:
CG
A rc hi te c st e r P la nn rio r D e si g n
C lo ve rd a le
B o ul e va rd
Fo rt
W a lto n
Be a c h, F lo rid a
Ph o ne
0)
-2 x:
(8
) 6
-6
F L
L i c e n s e
A
R
C o r p
L i c e n s e
A
A C
Architectural Inc.
Stokes
M ir a m a r
B ea ch
Fl o ri d a
Drift woo d Tr ansi t Sto p &
Rest room
- W alto n Co unty
D ri ft w o o d R o a d
PROFESSIONAL SEAL:
AR009663005/20/2024
AutoCAD SHX Text %%uEACH TO HAVE:
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text CELL POLYETHYLENE ISOLATION STRIP BETWEEN %%uALL%%u PRESSURE
AutoCAD SHX Text
TREATED WOOD FRAMING AND CONCRETE SURFACES. (TYPICAL)
AutoCAD SHX Text
CONTRACTOR TO PROVIDE AND INSTALL 1/8" CLOSED
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text %%uNOTE:
AutoCAD SHX Text
(SILL-SEAL) BY GEORGIA PACIFIC OR APPROVED EQUIVALENT.
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
PORCH
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
HEIGHT
AutoCAD SHX Text
FINISH
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text W A L L S
AutoCAD SHX Text C E I L I N G
AutoCAD SHX Text B A S E
AutoCAD SHX Text F L O O R
AutoCAD SHX Text R O O M
AutoCAD SHX Text
ONLY
AutoCAD SHX Text
NORTH WALL
AutoCAD SHX Text
ALL WALLS
AutoCAD SHX Text
NO.
AutoCAD SHX Text
ROOM
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text W
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text
IMPACT & MOISTURE RESISTANT GYP. BRD.
AutoCAD SHX Text
SILL
AutoCAD SHX Text
HEAD
AutoCAD SHX Text
JAMB
AutoCAD SHX Text
HARDWARE
AutoCAD SHX Text R E M A R K S
AutoCAD SHX Text
FINISH
AutoCAD SHX Text
FINISH
AutoCAD SHX Text
MAT'L
AutoCAD SHX Text
ELEV
AutoCAD SHX Text
MAT'L
AutoCAD SHX Text D O O R
AutoCAD SHX Text F R A M E
AutoCAD SHX Text S I Z E
AutoCAD SHX Text
DOOR NO.
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
OPENING
AutoCAD SHX Text
ELEV
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
PAINT
AutoCAD SHX Text A
AutoCAD SHX Text
SWING
AutoCAD SHX Text F1
AutoCAD SHX Text 1/A-150
AutoCAD SHX Text
EPOXY (6" AFF)
AutoCAD SHX Text
%%UHARDWARE MANUFACTURERS:
AutoCAD SHX Text
BUTTS:
AutoCAD SHX Text
LOCKSETS, LATCHSETS DEADBOLTS, HANDLESETS:
AutoCAD SHX Text
EXIT DEVICES, CLOSERS:
AutoCAD SHX Text
WALL STOPS, KICKPLATES, FLUSHBOLTS, ETC.
AutoCAD SHX Text
THRESHOLDS, WEATHERSTRIPPING,
AutoCAD SHX Text
OWNER SELECTED
AutoCAD SHX Text %%uKEYING
AutoCAD SHX Text
LOWER LEVEL
AutoCAD SHX Text
ALL LOCKSETS TO BE KEYED AS DIRECTED BY OWNER.
AutoCAD SHX Text
1) FRP = FIBERGLASS REINFORCED PLASTIC.
AutoCAD SHX Text
%%UNOTE:
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
1) ALL COLORS AND FINISHES TO BE OWNER SELECTED
AutoCAD SHX Text
%%UNOTE:
AutoCAD SHX Text 2/A-150
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
VINYL
AutoCAD SHX Text
AutoCAD SHX Text
SEALED CONCRETE
AutoCAD SHX Text 1x4 T&G PINE (STAINED)
AutoCAD SHX Text
OWNER SELECTED
AutoCAD SHX Text
OWNER SELECTED
AutoCAD SHX Text
OWNER SELECTED
AutoCAD SHX Text
OWNER SELECTED
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
SET # 1
AutoCAD SHX Text 3'-0" x 7'-0"
AutoCAD SHX Text
ENTRY
AutoCAD SHX Text
SET # 1
AutoCAD SHX Text
AutoCAD SHX Text
FRP
AutoCAD SHX Text
SET # 2
AutoCAD SHX Text
WAITING AREA
AutoCAD SHX Text
AutoCAD SHX Text
MEN
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text
AutoCAD SHX Text
JANITOR
AutoCAD SHX Text
AutoCAD SHX Text
EPOXY FLOORING (SLIP RESISTANT)
AutoCAD SHX Text
NONE
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
(2) 3'-0" x 7'-0"
AutoCAD SHX Text 3'-0" x 7'-0"
AutoCAD SHX Text not used
AutoCAD SHX Text
FRP
AutoCAD SHX Text
FRP
AutoCAD SHX Text
ENTRY
AutoCAD SHX Text
ENTRY
AutoCAD SHX Text
SWING
AutoCAD SHX Text
SWING
AutoCAD SHX Text F1
AutoCAD SHX Text F1
AutoCAD SHX Text
FRP
AutoCAD SHX Text
FRP
AutoCAD SHX Text
FRP
AutoCAD SHX Text 1/A-150
AutoCAD SHX Text 2/A-150
AutoCAD SHX Text 1/A-150
AutoCAD SHX Text 2/A-150
AutoCAD SHX Text
2) INSTALL DOOR CLOSER WITH 4" MIN. MASONRY SCREWS.
AutoCAD SHX Text
(4) HINGES
AutoCAD SHX Text
(1) DEADBOLT
AutoCAD SHX Text
(1) CLOSER
AutoCAD SHX Text
(1) PULL
AutoCAD SHX Text
(1) PUSH
AutoCAD SHX Text
(2) KICK PLATES
AutoCAD SHX Text
(1) DOOR STOP
AutoCAD SHX Text
(1) THRESHOLD
AutoCAD SHX Text
780-210 HAGER
AutoCAD SHX Text
630 HAGER
AutoCAD SHX Text
LCN 4010T SERIES
AutoCAD SHX Text
630 ROCKWOOD
AutoCAD SHX Text
630 ROCKWOOD
AutoCAD SHX Text
630 ROCKWOOD
AutoCAD SHX Text
630 ROCKWOOD
AutoCAD SHX Text
ALUM. HAGER
AutoCAD SHX Text
CYLINDERS IN ALL LOCKS BY BEST.
AutoCAD SHX Text %%uEACH TO HAVE:
AutoCAD SHX Text
(4) HINGES
AutoCAD SHX Text
(1) SERIES 3600 - #80 STOREROOM FUNCTION
AutoCAD SHX Text
(1) CLOSER
AutoCAD SHX Text
(1) PULL
AutoCAD SHX Text
(1) THRESHOLD
AutoCAD SHX Text
780-210 HAGER
AutoCAD SHX Text
630 HAGER
AutoCAD SHX Text
LCN 4010T SERIES
AutoCAD SHX Text
630 ROCKWOOD
AutoCAD SHX Text
ALUM. HAGER
AutoCAD SHX Text
CYLINDERS IN ALL LOCKS BY BEST.
AutoCAD SHX Text
2) EPOXY FLOORING: FIBERGLASS REINFORCED EPOXY FLOOR
AutoCAD SHX Text COATING SYSTEM w/ SLIP/CHEMICAL/GRAFFITI RESISTANT FINISH.
AutoCAD SHX Text
3) BASE CREATED BY EXTENDING EPOXY FLOORING 6" ABOVE
AutoCAD SHX Text
FINISHED FLOOR.
AutoCAD SHX Text
AutoCAD SHX Text
CHASE
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
AutoCAD SHX Text
SET # 2
AutoCAD SHX Text A
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
AutoCAD SHX Text 3'-0" x 7'-0"
AutoCAD SHX Text
FRP
AutoCAD SHX Text
ENTRY
AutoCAD SHX Text
SWING
AutoCAD SHX Text F1
AutoCAD SHX Text
FRP
AutoCAD SHX Text 1/A-150
AutoCAD SHX Text 2/A-150
AutoCAD SHX Text
AutoCAD SHX Text
SET # 2
AutoCAD SHX Text A
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
AutoCAD SHX Text 3'-0" x 7'-0"
AutoCAD SHX Text
FRP
AutoCAD SHX Text
ENTRY
AutoCAD SHX Text
SWING
AutoCAD SHX Text F1
AutoCAD SHX Text
FRP
AutoCAD SHX Text 1/A-150
AutoCAD SHX Text 2/A-150
AutoCAD SHX Text A
AutoCAD SHX Text
%%U"WF-1"
AutoCAD SHX Text B
AutoCAD SHX Text
%%U"WF-2"
AutoCAD SHX Text
SINGLE-HUNG
AutoCAD SHX Text
TRANSOM
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text %%U"B"
AutoCAD SHX Text
FIBERGLASS
AutoCAD SHX Text %%U"A"
AutoCAD SHX Text
FIBERGLASS
AutoCAD SHX Text
FULL LITE
AutoCAD SHX Text
2 PANEL
AutoCAD SHX Text
FRP
AutoCAD SHX Text %%U"F1"
AutoCAD SHX Text 2x6 SPF STUDS
AutoCAD SHX Text
BATT INSULATION
AutoCAD SHX Text
15/32" (MIN.) OSB
AutoCAD SHX Text
SHEATHING (SEE
AutoCAD SHX Text
STRUCTURAL)
AutoCAD SHX Text
TYVEK HOUSE WRAP
AutoCAD SHX Text
LAP SIDING
AutoCAD SHX Text
7 1/4" HARDIPLANK
AutoCAD SHX Text @ 16" O.C.
AutoCAD SHX Text
(R-19 MIN.)
AutoCAD SHX Text
PROVIDE WOOD
AutoCAD SHX Text
BLK'G AS NEEDED
AutoCAD SHX Text 2x4 SPF STUDS
AutoCAD SHX Text @ 16" O.C.
AutoCAD SHX Text
PROVIDE WOOD
AutoCAD SHX Text
BLK'G AS NEEDED
AutoCAD SHX Text 2x6 SPF STUDS
AutoCAD SHX Text @ 16" O.C.
AutoCAD SHX Text
PROVIDE WOOD
AutoCAD SHX Text
BLK'G AS NEEDED
AutoCAD SHX Text 2x6 SPF STUDS
AutoCAD SHX Text @ 16" O.C.
AutoCAD SHX Text
PROVIDE WOOD
AutoCAD SHX Text
BLK'G AS NEEDED
AutoCAD SHX Text
5/8" GYPSUM BD
AutoCAD SHX Text
IMPACT, MOLD, &
AutoCAD SHX Text
MOISTURE RESISTANT
AutoCAD SHX Text
5/8" GYPSUM BD
AutoCAD SHX Text
IMPACT, MOLD, &
AutoCAD SHX Text
MOISTURE RESISTANT
AutoCAD SHX Text
5/8" GYPSUM BD
AutoCAD SHX Text
IMPACT, MOLD, &
AutoCAD SHX Text
MOISTURE RESISTANT
AutoCAD SHX Text
5/8" GYPSUM BD
AutoCAD SHX Text
IMPACT, MOLD, &
AutoCAD SHX Text
MOISTURE RESISTANT
AutoCAD SHX Text F R A M E
AutoCAD SHX Text G L A Z I N G
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
WDW
AutoCAD SHX Text
NO.
AutoCAD SHX Text S I Z E
AutoCAD SHX Text
JAMB
AutoCAD SHX Text
HEAD
AutoCAD SHX Text
SILL
AutoCAD SHX Text
TEMP
AutoCAD SHX Text A
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
VINYL
AutoCAD SHX Text 3'-5" x 5'-4"
AutoCAD SHX Text
INSULATED
AutoCAD SHX Text
ELEV
AutoCAD SHX Text
WF-1
AutoCAD SHX Text R E M A R K S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NO
AutoCAD SHX Text
S HUNG
AutoCAD SHX Text
FINISH
AutoCAD SHX Text
MAT'L
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text
VINYL
AutoCAD SHX Text 3'-5" x 1'-0"
AutoCAD SHX Text
INSULATED
AutoCAD SHX Text
WF-2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NO
AutoCAD SHX Text
FIXED
AutoCAD SHX Text
AutoCAD SHX Text
IMPACT
AutoCAD SHX Text
IMPACT
AutoCAD SHX Text
IMPACT
AutoCAD SHX Text
IMPACT
AutoCAD SHX Text
DOOR SWEEP
AutoCAD SHX Text
ALUMINUM THRESHOLD
AutoCAD SHX Text SET IN SEALANT w/
AutoCAD SHX Text
COUNTERSUNK FASTENERS
AutoCAD SHX Text
IN EXPANSION SHIELDS
AutoCAD SHX Text
@ 12" O.C. (MAX.)
AutoCAD SHX Text
SEALANT
AutoCAD SHX Text
FIBERGLASS DOOR
AutoCAD SHX Text
FIBERGLASS DOOR
AutoCAD SHX Text
FRAME
AutoCAD SHX Text 2x6 WOOD FRAMING
AutoCAD SHX Text
FIBERGLASS DOOR
AutoCAD SHX Text
FRAME
AutoCAD SHX Text
FIBERGLASS DOOR
AutoCAD SHX Text
HARDI TRIM
AutoCAD SHX Text
SHEATHING
AutoCAD SHX Text
HARDI SIDING
AutoCAD SHX Text 2x12 WOOD HEADER
AutoCAD SHX Text
FIBERGLASS DOOR
AutoCAD SHX Text
FRAME
AutoCAD SHX Text
FIBERGLASS DOOR/LOUVER
AutoCAD SHX Text
HARDI TRIM
AutoCAD SHX Text
SHEATHING
AutoCAD SHX Text
HARDI SIDING
AutoCAD SHX Text 2x6 WOOD FRAMING
AutoCAD SHX Text
WOOD TRIM
AutoCAD SHX Text
INTERIOR WALL BOARD
AutoCAD SHX Text
(SEE WALL TYPES)
AutoCAD SHX Text
INTERIOR WALL BOARD
AutoCAD SHX Text
(SEE WALL TYPES)
Front Elevation1
A-200
SCALE: 1/4" = 1'-0"
Rear Elevation2
A-200
SCALE: 1/4" = 1'-0"
Side Elevation3
A-200
SCALE: 1/4" = 1'-0"
Side Elevation3
A-200
EXTERIOR
A-200
ELEVATIONS
5/20/2024
DRAWING NUMBER:
DATE: FILE:
SHEET TITLE:
APPROVED BY:
REVISIONS:
21014
St o ke s
A rc hi te c tu ra l, In c
St o ke s
A rc hi te c tu ra l, in c
. h e re b y e xp re ss ly re se rv e s its c o m m o n-la w c o p yr ig ht a nd o th e r p ro p e rty ri g ht s to th e se p la ns
D ra w in g s a re n o t t o b e re p ro d uc e d , c ha ng e d
, o r c o p ie d in a ny fo rm w ha ts o e ve r, no r a re th e y to b e a ss ig ne d to a ny th ird p a rty w ith o ut fi rs t o b ta in in g th e e xp re ss w rit te n p e rm is si o n a nd c o ns e nt o f S to ke s A rc hi te c tu ra l, in c
DRAWN BY:
CG
CHECKED BY:
CG
A rc hi te c st e r P la nn rio r D e si g n
C lo ve rd a le
B o ul e va rd
Fo rt
W a lto n
Be a c h, F lo rid a
Ph o ne
0)
-2 x:
(8
) 6
-6 c e n
A
R
C o r p c e n
A
A C
Architectural Inc.
Stokes
M ir a m a r
B ea ch
Fl o ri d a
Drift woo d Tr ansi t Sto p &
Rest room
- W alto n Co unty
D ri ft w o o d R o a d
PROFESSIONAL SEAL:
AR009663005/20/2024
AutoCAD SHX Text
TOP OF SLAB
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text
TOP OF PLATE
AutoCAD SHX Text 9'-4"
AutoCAD SHX Text
TOP OF RIDGE
AutoCAD SHX Text 13'-9"
AutoCAD SHX Text
TOP OF ROOF
AutoCAD SHX Text 15'-6"
AutoCAD SHX Text
TOP OF SLAB
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text
TOP OF PLATE
AutoCAD SHX Text 9'-4"
AutoCAD SHX Text
TOP OF RIDGE
AutoCAD SHX Text 13'-9"
AutoCAD SHX Text
TOP OF SLAB
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text
TOP OF PLATE
AutoCAD SHX Text 9'-4"
AutoCAD SHX Text
TOP OF SLAB
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text
TOP OF PLATE
AutoCAD SHX Text 9'-4"
AutoCAD SHX Text
TOP OF ROOF
AutoCAD SHX Text 15'-6"
AutoCAD SHX Text
TOP OF ROOF
AutoCAD SHX Text 15'-6"
AutoCAD SHX Text
TOP OF ROOF
AutoCAD SHX Text 15'-6"
AutoCAD SHX Text
CEMENTITOUS CORNER TRIM
AutoCAD SHX Text
CEMENTITOUS CORNER TRIM
AutoCAD SHX Text
STANDING SEAM METAL ROOF
AutoCAD SHX Text
CEMENTITOUS LAP SIDING
AutoCAD SHX Text
CEMENTITOUS LAP SIDING
AutoCAD SHX Text
STANDING SEAM METAL ROOF
AutoCAD SHX Text
DECORATIVE GABLE VENT
STANDING SEAM METAL ROOF
Building Section1
A-250
SCALE: 1/4" = 1'-0"
Building Section2
A-250
SCALE: 3/4" = 1'-0"
Wall Section4
A-250
A-250
SCALE: 1/4" = 1'-0"
Building Section3
A-250
BUILDING SECTIONS /
A-250
WALL SECTION
5/20/2024
DRAWING NUMBER:
DATE: FILE:
SHEET TITLE:
APPROVED BY:
REVISIONS:
21014
St o ke s
A rc hi te c tu ra l, In c
St o ke s
A rc hi te c tu ra l, in c
. h e re b y e xp re ss ly re se rv e s its c o m m o n-la w c o p yr ig ht a nd o th e r p ro p e rty ri g ht s to th e se p la ns
D ra w in g s a re n o t t o b e re p ro d uc e d , c ha ng e d
, o r c o p ie d in a ny fo rm w ha ts o e ve r, no r a re th e y to b e a ss ig ne d to a ny th ird p a rty w ith o ut fi rs t o b ta in in g th e e xp re ss w rit te n p e rm is si o n a nd c o ns e nt o f S to ke s A rc hi te c tu ra l, in c
DRAWN BY:
CG
CHECKED BY:
CG
A rc hi te c st e r P la nn rio r D e si g n
C lo ve rd a le
B o ul e va rd
Fo rt
W a lto n
Be a c h, F lo rid a
Ph o ne
0)
-2 x:
(8
) 6
-6 c e n
A
R
C o c e n
A
A C
Architectural Inc.
Stokes
M ir a m a r
B ea ch
Fl o ri d a
Drift woo d Tr ansi t Sto p &
Rest room
- W alto n Co unty
D ri ft w o o d R o a d
PROFESSIONAL SEAL:
AR009663005/20/2024
AutoCAD SHX Text
TOP OF SLAB
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text
TOP OF PLATE
AutoCAD SHX Text +9'- 1/2" ;
AutoCAD SHX Text
TOP OF ROOF
AutoCAD SHX Text +15'-3 3/4" ;
AutoCAD SHX Text
TOP OF SLAB
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text
TOP OF PLATE
AutoCAD SHX Text +9'-4 1/2"
AutoCAD SHX Text
TOP OF ROOF
AutoCAD SHX Text +15'-3 3/4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
STANDING SEAM METAL ROOF
AutoCAD SHX Text
CEMENTITOUS SIDING
AutoCAD SHX Text
EXPOSED RAFTER TAILS (TYP.)
AutoCAD SHX Text
STANDING SEAM METAL ROOF
AutoCAD SHX Text
STICK FRAMED ROOF
AutoCAD SHX Text
SLOPE 1/8":12"
AutoCAD SHX Text
O.H. (TYP.)
AutoCAD SHX Text
CONC. SLAB (SEE STRUCT. DWGS)
AutoCAD SHX Text
FOUNDATION SYSTEM
AutoCAD SHX Text
(SEE STRUCTURAL)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text CASED OPENING w/ TOILET
AutoCAD SHX Text
O.H. (TYP.)
AutoCAD SHX Text
TOP OF SLAB
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text
TOP OF PLATE
AutoCAD SHX Text +9'-4 1/2" ;
AutoCAD SHX Text
TOP OF ROOF
AutoCAD SHX Text +15'-3 3/4" ;
AutoCAD SHX Text
FURRED OUT COLUMN
AutoCAD SHX Text
FOUNDATION SYSTEM
AutoCAD SHX Text
(SEE STRUCTURAL)
AutoCAD SHX Text
ROOF FRAMING
AutoCAD SHX Text
(SEE STRUCTURAL)
AutoCAD SHX Text
TOILET DOOR )TYP. OF
AutoCAD SHX Text
TOP OF WALL
AutoCAD SHX Text +8'-0"
AutoCAD SHX Text
ALL STALLS)
AutoCAD SHX Text
FRP WALL COVERING
AutoCAD SHX Text
TOP OF WALL
AutoCAD SHX Text +8'-0"
AutoCAD SHX Text
TOP OF FRP
AutoCAD SHX Text +6'-3 1/2"
AutoCAD SHX Text
TOP OF FRP
AutoCAD SHX Text +6'-3 1/2"
AutoCAD SHX Text
R-38 SPRAY FOAM
AutoCAD SHX Text
INSULATION @
AutoCAD SHX Text
R-38 SPRAY FOAM
AutoCAD SHX Text
INSULATION (TYP.)
AutoCAD SHX Text
R-19 BATT
AutoCAD SHX Text
INSULATION @
AutoCAD SHX Text
ALL EXTERIOR
AutoCAD SHX Text
ROOF (TYP.)
AutoCAD SHX Text
WALLS (TYP.)
AutoCAD SHX Text
GYPSUM BOARD CEILING
AutoCAD SHX Text
TOP OF SLAB
AutoCAD SHX Text 0'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
O.H. (TYP.)
AutoCAD SHX Text
CEMENTITOUS PANEL OVER PT COLUMN
AutoCAD SHX Text
DEEP FOUNDATION SYSTEM
AutoCAD SHX Text
(SEE STRUCT. DWGS.)
AutoCAD SHX Text
STANDING SEAM METAL ROOF
AutoCAD SHX Text
METAL FLASHING W/ DRIP EDGE
AutoCAD SHX Text
(COLOR TO MATCH ROOF)
AutoCAD SHX Text
PEEL AND STICK ROOF
AutoCAD SHX Text
UNDERLAYMENT (DOUBLE
AutoCAD SHX Text
LAYER @ PINE/PLYWD. JOINT)
AutoCAD SHX Text
3/4" CEMENTITOUS TRIM
AutoCAD SHX Text
3/4" CEMENTITOUS TRIM
AutoCAD SHX Text 2x8 T&G ROOF DECK w/ (3)
AutoCAD SHX Text 10d NAILS EA. BOARD @ RAFTERS
AutoCAD SHX Text 2x8 RAFTER w/ EXPOSED TAIL
AutoCAD SHX Text
BEAM (SEE STRUCTURAL)
AutoCAD SHX Text
CEMENTITOUS TRIM
AutoCAD SHX Text
3/4" MITERED CEMENTITOUS TRIM
AutoCAD SHX Text CAP w/ 1" OVERHANG (TYP.)
AutoCAD SHX Text
3/4" MITERED CEMENTITOUS TRIM
AutoCAD SHX Text CAP w/ 1" OVERHANG (TYP.)
AutoCAD SHX Text & 2x FURRING AS REQ. (SEE STRUCTURAL)
AutoCAD SHX Text 2x8s EXPOSED @ PORCH
AutoCAD SHX Text
& SOFFITS
Women's & Men's Restroom1
A-300
Toilet Room Accessory Schedule
INTERIOR ELEVATIONS
A-300 5/20/2024
DRAWING NUMBER:
DATE: FILE:
SHEET TITLE:
APPROVED BY:
REVISIONS:
21014
St o ke s
A rc hi te c tu ra l, In c
St o ke s
A rc hi te c tu ra l, in c
. h e re b y e xp re ss ly re se rv e s its c o m m o n-la w c o p yr ig ht a nd o th e r p ro p e rty ri g ht s to th e se p la ns
D ra w in g s a re n o t t o b e re p ro d uc e d , c ha ng e d
, o r c o p ie d in a ny fo rm w ha ts o e ve r, no r a re th e y to b e a ss ig ne d to a ny th ird p a rty w ith o ut fi rs t o b ta in in g th e e xp re ss w rit te n p e rm is si o n a nd c o ns e nt o f S to ke s A rc hi te c tu ra l, in c
DRAWN BY:
CG
CHECKED BY:
CG
A rc hi te c st e r P la nn rio r D e si g n
C lo ve rd a le
B o ul e va rd
Fo rt
W a lto n
Be a c h, F lo rid a
Ph o ne
0)
-2 x:
(8
) 6
-6 c e n
A
R
C o c e n
A
A C
Architectural Inc.
Stokes
M ir a m a r
B ea ch
Fl o ri d a
Drift woo d Tr ansi t Sto p &
Rest room
- W alto n Co unty
D ri ft w o o d R o a d
PROFESSIONAL SEAL:
AR009663005/20/2024
AutoCAD SHX Text
MOUNT 34" A.F.F. TO C
AutoCAD SHX Text
MOUNT 34" A.F.F. TO C
AutoCAD SHX Text
MOUNT 40" A.F.F.
AutoCAD SHX Text
NO.
AutoCAD SHX Text
GRAB BAR
AutoCAD SHX Text
GRAB BAR
AutoCAD SHX Text
HAND DRYER
AutoCAD SHX Text
MIRROR
AutoCAD SHX Text A
AutoCAD SHX Text
TOILET TISSUE DISPENSER
AutoCAD SHX Text
3'-0" LONG -
AutoCAD SHX Text
3'-6" LONG -
AutoCAD SHX Text
WALL MOUNTED -
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
NOTES
AutoCAD SHX Text L
AutoCAD SHX Text L
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
WORLD DRYER
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text
WALL MOUNTED - MOUNT 46" A.F.F.
AutoCAD SHX Text
MODEL
AutoCAD SHX Text B-680636
AutoCAD SHX Text B-680642
AutoCAD SHX Text B-293 1836
AutoCAD SHX Text
WA126
AutoCAD SHX Text B-2890
AutoCAD SHX Text
BABY CHANGING STATION
AutoCAD SHX Text
KOALA BEAR KARE
AutoCAD SHX Text
KB100
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text
SANITARY NAPKIN DISPOSAL
AutoCAD SHX Text B-5270
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text
TRASH RECEPTACLE
AutoCAD SHX Text
MOP / BROOM HOLDER
AutoCAD SHX Text B-223
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text B-5277
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text J
AutoCAD SHX Text
MOUNT 40" A.F.F.
AutoCAD SHX Text
MIRROR
AutoCAD SHX Text
WALL MOUNTED -
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text B-165 1830
AutoCAD SHX Text
MOUNT 34" TO TOP OF CHANGING SURFACE A.F.F.
AutoCAD SHX Text
WALL MOUNTED -
AutoCAD SHX Text
WALL MOUNTED - MOUNT 19" A.F.F.
AutoCAD SHX Text
WALL MOUNTED - MOUNT 19" A.F.F.
AutoCAD SHX Text
COAT HOOK
AutoCAD SHX Text 818615
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text L
AutoCAD SHX Text
WALL MOUNTED - MOUNT 28" A.F.F.
AutoCAD SHX Text
WALL MOUNTED - MOUNT 48" A.F.F.
AutoCAD SHX Text
WALL MOUNTED - MOUNT 46" A.F.F.
AutoCAD SHX Text B-212
AutoCAD SHX Text
WALL MOUNTED - MOUNT 48" @ HC STALL, 60" ELSEWHERE A.F.F.
AutoCAD SHX Text K
AutoCAD SHX Text
SOAP DISPENSER
AutoCAD SHX Text
BOBRICK
AutoCAD SHX Text
GYPSUM BOARD
AutoCAD SHX Text 1x4 CEMENTITOUS TRIM BOARD
AutoCAD SHX Text
FRP
AutoCAD SHX Text
BASE AS SCHEDULED
AutoCAD SHX Text 1x6 CEMENTITOUS TRIM BOARD
AutoCAD SHX Text
GYPSUM BOARD
AutoCAD SHX Text 1x4 CEMENTITOUS TRIM BOARD
AutoCAD SHX Text
FRP
AutoCAD SHX Text
BASE AS SCHEDULED
AutoCAD SHX Text
%%UA
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text T.O.W 8'-0"
Roof Plan1
A-400
N
SCALE: 1 1/2" = 1'-0"
Ridge Detail2
A-400
SCALE: 1 1/2" = 1'-0"
Rafter Detail3
A-4003
A-200
A-200
A-200
A-200
A-250
A-250
A-250
ROOF PLAN
A-400
& DETAILS
5/20/2024
DRAWING NUMBER:
DATE: FILE:
SHEET TITLE:
APPROVED BY:
REVISIONS:
21014
St o ke s
A rc hi te c tu ra l, In c
St o ke s
A rc hi te c tu ra l, in c
. h e re b y e xp re ss ly re se rv e s its c o m m o n-la w c o p yr ig ht a nd o th e r p ro p e rty ri g ht s to th e se p la ns
D ra w in g s a re n o t t o b e re p ro d uc e d , c ha ng e d
, o r c o p ie d in a ny fo rm w ha ts o e ve r, no r a re th e y to b e a ss ig ne d to a ny th ird p a rty w ith o ut fi rs t o b ta in in g th e e xp re ss w rit te n p e rm is si o n a nd c o ns e nt o f S to ke s A rc hi te c tu ra l, in c
DRAWN BY:
CG
CHECKED BY:
CG
A rc hi te c st e r P la nn rio r D e si g n
C lo ve rd a le
B o ul e va rd
Fo rt
W a lto n
Be a c h, F lo rid a
Ph o ne
0)
-2 x:
(8
) 6
-6 c e n s e
A
R
C o r p
L i c e n
A
A C
Architectural Inc.
Stokes
M ir a m a r
B ea ch
Fl o ri d a
Drift woo d Tr ansi t Sto p &
Rest room
- W alto n Co unty
D ri ft w o o d R o a d
PROFESSIONAL SEAL:
AR009663005/20/2024
AutoCAD SHX Text
RIDGE
AutoCAD SHX Text 4 : 12
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text 4 : 12
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text 4 : 12
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text 4 : 12
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text 4 : 12
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text 4 : 12
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
HIP
AutoCAD SHX Text
HIP
AutoCAD SHX Text
HIP
AutoCAD SHX Text
HIP
AutoCAD SHX Text
RIDGE
AutoCAD SHX Text
VALLEY
AutoCAD SHX Text
VALLEY
AutoCAD SHX Text
STANDING SEAM METAL ROOF
AutoCAD SHX Text
METAL DRIP EDGE (TYP.)
AutoCAD SHX Text
STANDING SEAM
AutoCAD SHX Text
METAL ROOF
AutoCAD SHX Text
RIDGE CAP
AutoCAD SHX Text 2x8 T&G ROOF DECK
AutoCAD SHX Text
RAFTERS (SEE STRUCTURAL)
AutoCAD SHX Text
SPRAY FOAM INSUALTION
AutoCAD SHX Text
CROSS TIES (SEE STRUCTURAL)
AutoCAD SHX Text
PEEL & STICK ROOF
AutoCAD SHX Text
UNDERLAYMENT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
STANDING SEAM
AutoCAD SHX Text
METAL ROOF
AutoCAD SHX Text 2x8 T&G ROOF DECK
AutoCAD SHX Text
RAFTERS (SEE STRUCTURAL)
AutoCAD SHX Text
PEEL & STICK ROOF
AutoCAD SHX Text
UNDERLAYMENT
AutoCAD SHX Text
SPRAY FOAM INSUALTION
AutoCAD SHX Text
AutoCAD SHX Text
SECTION 00700 - GENERAL CONDITIONS
PART 1 GENERAL CONDITIONS
A. The "General Conditions of the Contract for Construction" of the American
Institute of Architect, AIA Document are an integral part of the Specifications as if written in full herein.
B. Copies of the "General Conditions" may be purchased from the Florida
Association of the American Institute of Architects, Document Department, P.O. Box
10388, Tallahassee, Florida, 32302.
C. The Contractor is hereby specifically directed, as a condition of the Contract, to obtain the necessary number of copies of Documents to acquaint himself with the
Articles contained therein and to notify and appraise all Subcontractors, Suppliers and any other parties of the Contract or individuals or agencies engaged in the work as to its contents.
D. No contractual adjustments shall be due or become exigent as a result of, or failure on the part of the Contractor to fully acquaint himself and all other parties to the contract with the conditions of Documents.
E. Supplementary Conditions That Apply to this Project:
1. This Project requires Florida Product Approval for products or system of construction that comply with Rule 9B-72.070 of the Florida Administrative Code.
State Product Approval means the acceptance of a product on a state or regional basis consistent with an evaluation conducted pursuant to Rule 9B-72.070, F.A.C.
2. Provide products and system of construction as required for items of Work indicated in the Drawings and Specifications that have been tested and approved to receive a Florida Product Approval.
3. Furnish to Architect two copies of documentation for each product indicating a
Florida Product Approval Number that comply with the structural requirements of the Florida Building Code for the following items of Work comprising the building envelope and structural frame (comply with FBC requirements for wind-borne debris region of 140 mph.per ASCE 7-98):
(a) For panel walls: siding, soffits, exterior insulation finish system (EIFS), storefronts, curtain walls, wall louver, glass block, membrane, greenhouse and products introduced as a result of new technology;
(b) For exterior doors:
1. Exterior door assemblies: roll-up, sectional, sliding, swinging, automatic;
pre-engineered roof access hatches; and products introduced as a result of new technology;
2. Exterior door components and products introduced as a result of new technology;
(c) For windows: awning, casement, dual action, double hung, single hung, fixed, horizontal slider, projected, pass through, mullions, and products introduced as a result of new technology;
(d) For roofing products: built up roofing, modified bitumen roof system, single ply roof systems, spray applied polyurethane roof system, roofing fasteners, roofing insulation, asphalt shingles, wood shingles and shakes, roofing slate, roof tile adhesives, cements-adhesives-coatings, liquid applied roof systems, underlayments, non-structural metal roofing, roofing tiles, waterproofing, roofing accessories that are an integral part of the roofing system and products introduced as a result of new technology;
(e) For shutters: accordion, Bahama, storm panels, colonial, roll-up, pre-engineered equipment, protection, and products introduced as a result of new technology;
(f) For skylights: skylight, and products introduced as a result of new technology;
and
(g) For structural components: truss plates, wood connectors, anchors, exterior coolers-freezers, sheds, concrete admixtures, insulation forms and systems, engineered lumber, pre-engineered air conditioner stands, materials, plastics, structural wall components, roof deck, railing and other products introduced as a result of new technology.
(h) Products Comprising a Building's Envelope Introduced as a Result of New
Technology (as applicable).
F. Products specifically addressed in the code through performance criteria and standard test methods or standard comparative or rational analysis methods, which cannot be approved through the plan review and inspection process, shall demonstrate compliance with the Code as outlined in F.A.C. 9B-72.070 "Product
Evaluation and Quality Assurance for State Approval."
E N D O F S E C T I O N 0 0 7 0 0 - G E N E R A L C O N D I T I O N S
SECTION 02361 - TERMITE CONTROL
PART 1 - GENERAL
A. This Section includes the following for termite control: soil treatment.
B. Regulatory Requirements: Formulate and apply termiticides, and label with a
Federal registration number, to comply with EPA regulations and authorities having jurisdiction.
PART 2 - PRODUCTS (Not Used)
PART 3 - EXECUTION
A. General: Comply with the most stringent requirements of authorities having jurisdiction and with manufacturer's EPA-Registered Label for products.
B. Soil treatment shall be required under all footings, slabs on grade, and sidewalks that adjoin new or existing buildings. Soil treatment shall not be applied until excavating, filling, compacting, and grading operations are complete.
C. Contractor shall exercise caution to prevent disturbance of the treated area. If any area is required to be re-treated, through no fault of the Owner, it will be done at the Contractor's expense.
E N D O F S E C T I O N 0 2 3 6 1 - T E R M I T E C O N T R O L
SECTION 05500 - METAL FABRICATIONS
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of contract, including General Conditions Apply to the work of this section.
1.2 DESCRIPTION
A. Definition: Metal fabrications includes items made from iron and steel shapes, plates, bars, strips, tubes, pipes and castings which are not a part of structural steel or other metal systems specified.
B. Types of work in this section include metal fabrications for: Rough Hardware, Loose steel framing and Supports, and Accessories.
1.3 CODES AND STANDARDS
A. AISC "Specifications for the Design, Fabrication and Erection of Structural Steel for Buildings"; AWS "Structural Welding Code", comply with applicable provisions unless otherwise indicated.
1.4 QUALITY ASSURANCE
A. Field Measurements: Take field measurements prior to preparation of shop drawings and fabrication, where possible. Do not delay job progress, allow for trimming and fitting where taking field measurement before fabrication might delay work.
B. Shop Assembly: Pre-assemble items in shipping to greatest extent possible to minimize field splicing and assembly. Units may be disassembled but only as necessary for shipping and handling limitations. Clearly mark units for reassembly and perform coordinated installation so that the assembled unit will be of equivalent work as that assembled in the shop.
1.5 SUBMITTALS
A. Product Data: Submit manufacturer's specifications, anchor details and installation instructions for products used in working with miscellaneous metal fabrications, including paint products and grout.
B. Shop Drawings: Submit shop drawings for approval prior to the fabrication and erection of miscellaneous metal fabrications.
This is the start of the file's text. The full file is on GovTribe.