Drawings - Elem Dorm Wing.pdf
PDF 1 MB Posted
- Attached to
- WVSDB ED Roof
- Solicitation number
- CRFQ 0403 DBS2700000001 2
- Issued by
- Kanawha County, West Virginia
About this file
This document is a set of architectural drawings for an elementary dormitory wing prepared for the West Virginia School for the Deaf and Blind (WVSDB) ED Roof project. The drawings provide detailed construction specifications and layout plans for the dormitory facility, including floor plans, elevations, sections, and structural details necessary for the roofing and related construction work. The drawings serve as the technical foundation for bidders to understand the scope of work, site conditions, and construction requirements associated with the roof replacement or renovation project at the WVSDB facility.
The drawings include dimensional specifications, material callouts, and construction details that establish the baseline requirements for completing the roofing work on the elementary dormitory wing. These architectural plans enable contractors to accurately assess project scope, labor requirements, materials needed, and associated costs for bid preparation. The drawings are essential reference documents for the project and should be reviewed in conjunction with the scope of work, specifications, and all addenda issued for the WVSDB ED Roof contract opportunity.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LP-100 - Lightning Protection Plan LP-101 - Lightning Protection Details M-100 - Mechanical Roof Plan and Details
Drawing Index A-100 - Roof Plan and Details
Hampshire County
Building Codes
State Building Code - Adopted August 1, 2022 State Fire Code - Adopted May 1, 2024 American Disabilities Act 2010 Standards for Accessible Design p.304.345.1060 f 304.345.3693 www.wsgarch.com
Charleston, WV 25302 717 Bigley Avenue
WILLIAMSON SHRIVER ARCHITECTS
p.412.931.8888 f.412.939.2525 www.tower-engineering.com
Pitssburg, PA 15229
REENIGNE NI G
115 Evergreen Heights Drive, Suite 400
I-79
I-64
I-77
I-77
I-68
I-81
I-70
I-64
I-64
I-77
Clarksburg
Parkersburg
Charleston Huntington
Beckley
Morgantown for the:
County Map Vicinity Map
Roof Replacement at the Elementary Dorm Wing
Romney, West Virginia
West Virginia Board of Education Charleston, West Virgina
May 29, 2026
Construction Documents
WVSDB
ROMNEY
WV Rt 28
US 50
Architects Comm. #2026-068
DN
EX. SLATE ROOF
ELEMENTARY DORM WING BUILDING
APPROX. 52' - 10"
A
PP
R O
X.
V.
V.
RAISED ROOF OVER
ELEVATOR, 3'-6" ABV.
ROOF. REMOVE EX. EPDM
AND REROOF USING NEW
EPDM OVER 1/2" INSUL.
EX. VENTILATOR
TO REMAIN. FLASH
INTO NEW ROOFING
EF
EF
EF
RD
RD
REMOVE VERT.
CONDUIT
DEMOLISH AND RE-BUILD A
4' X 4' AREA OF THE BRICK
PARAPET WALL IN THIS AREA.
RE-USE EXISTING FACE BRICK
FOR THE EXPOSED EXTERIOR
WYTHE OF BRICK. ANY NEW
BRICK FOR THE INTERIOR
WYTHES TO BE TYPE 'FBX'.
MORTAR TO COMPLY WITH
ASTM C 91, TYPE 'S'.
INSTALL HORIZONTAL GALV.
LADDER TYPE REINFORCING
SPACED 8" O.C. VERTICALLY.
V.
V.
V.
V.
V. V.
V.
V.
V.
V.
V.
V.
V.
V.
V.
14' - 0"
UP
EX. STEEL STAIR
TO REMAIN
REMOVE EX. 26" X 9" PITCH POCKET
RD
RD
RD
EX. 10" X 12" PITCH
POCKET AT ELEC. CONDUIT.
REPLACE WITH NEW
POURABLE SEALER POCKET
NEW STEEL LADDER,
COORDINATE LOCATION WITH
EX. WALL VENTS BELOW AND EX.
PLUMB. VENT ON ROOF. SEE
DETAILS THIS SHEET
PL
A
TF
O R M
OS
OS
OS
OS
TIC
TIC
TIC
T.I.C.
TIC
A-100
A-100
RE-BUILD BRICK PARAPET
WALL IN THIS AREA. APPROX.
1'-0" IN HT. X 10'-0" LONG
PLATFORM
4' - 6"
MTL. BASE
6¾"
14½"
ONE STORY CONNECTOR
APPROX. 39' - 0"
TWO STORY BUILDING
HIGH ROOF:
REMOVE EXISTING ROOFING AND INSULATION DOWN TO THE
CONCRETE ROOF DECK.
EXISTING ROOF IS 1/2" PITCH AND GRAVEL OVER 1-1/2"
PERLITE MOPPED TO THE DECK IN ASPHALT AND PITCH.
INSTALL NEW EPDM ROOFING OVER 1/4"/FT. TAPERED
ROOF INSULATION.
LOW ROOF:
REMOVE EXISTING ROOFING AND INSULATION DOWN TO THE
CONCRETE ROOF DECK.
EXISTING ROOF IS 1/2" PITCH AND GRAVEL OVER 1-1/2"
PERLITE MOPPED TO THE DECK IN ASPHALT AND PITCH.
INSTALL NEW EPDM ROOFING OVER 1/4"/FT. TAPERED
ROOF INSULATION.
INSULATION THICKNESS TO BE 2"
MINIMUM (TYPICAL) AT THE UPPER
ROOFS 4 DRAINS.
INSULATION THICKNESS AT
ROOF DRAIN TO BE 4"
MINIMUM
14½"
14½"
14½"
11¾"
11¾"
7"
APPROX.
1"/FT.
1/4"/FT.
1/4"/FT.
APPROX.
5/16"/FT.
APPROX.
5/8"/FT.
1/4"/FT.
ALIGN INSUL. RIDGE
W/ CORNER OF
RAISED ROOF
7"
7¾"
10¾"
1' - 0"50' - 6"
TAPERED INSUL. CRICKET
SLOPE 1/4"/FT.
30" x 30" ROOFWALK
TOP OF MASONRY
OVERFLOW SCUPPER, SEE
DETAIL 5/A-100
RD EX. ROOFDRAIN TO BE REPLACE W/ NEW
ROOF DRAIN - SEE DETAIL 4/A-100
OS
7"
TIC
ME
TOM
ROOF SLOPES DOWN
THIS DIRECTION
ROOF LEGEND
MECHANICAL EQUIPMENT
SEE MECHANICAL DWGS
INDICATES THICKNESS OF TAPERED
INSULATION AT THIS POINT
(INCLUDING BASE INSUL)
EXISTINGEX.
GENERAL NOTES:
CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS,
DIMENSIONS AND ELEVATIONS AT THE SITE. WHERE
CONDITIONS VARY FROM THOSE SHOWN ON PLANS,
CONTRACTOR SHALL OBTAIN AUTHORIZATION BEFORE
PROCEEDING WITH ADJUSTMENTS NECESSARY FOR WORK.
1.
2.
3.
ALL EXISTING ROOF DRAINS TO BE REPLACED WITH NEW
ROOF DRAINS. EXISTING ROOF DRAIN PIPING HAS
INSULATION THAT MAY CONTAIN HAZARDOUS
MATERIALS. REFER TO SPEC. SECTION 024119
SELECTIVE DEMOLITION.
REMOVE EXISTING LIGHTNING PROTECTION SYSTEM.
INSTALL NEW PROTECTION SYSTEM, SEE ELEC. DWGS.
AND SPECIFICATIONS.
4. ROOF INSULATION TO BE INSTALLED IN TWO OR MORE
LAYERS WITH THE JOINTS STAGGERED IN EACH DIRECTION.
CODED PLAN NOTES 0
ALL EXISTING CONCRETE COPINGS TO BE REMOVED.
INSTALL NEW FASCIA AS PER DETAIL 1/A-100.
REMOVE EXISTING FLASHING AT ALL PARAPET WALLS.
INSTALL NEW EPDM FLASHING TO EXTEND UP AND OVER
PARAPET WALLS AS PER DETAIL 1/A-100.
EXISTING VENTILATOR / FAN TO BE REMOVED, SEE
MECH. DRAWINGS. PATCH ROOF DECK WITH 16 GA.
STEEL PLATE, FASTENED TO CONC. DECK AT EACH
CORNER.
EXTEND NEW ROOF MEMBRANE AND FLASHING THRU
PARAPET PASS THRU AND TERMINATE ON OUTSIDE FACE
OF WALL WITH TERM. BAR.
REMOVE EX. STEEL STAIR.
INSTALL NEW CODE COMPLIANT ALUM. STAIR WITH
4'-6" x 7'-0" UPPER PLATFORM AND A 44" WIDE STAIR.
FIELD VERIFY REQ'D STAIR HT.. PROVIDE MAX. 7" RISERS
AND MIN. 11" TREADS. PLATFORM TO BE LEVEL WITH THE
EX. STONE SILL AT DOOR. SET LEG SUPPORTS ON A METAL
BASE & NEW WALK PADS. BOLT PLATFORM TO EXISTING
BRICK WALL.
PROVIDE 'ERECT-A-STEP' PORTABLE STAIR OR
EQUAL PRODUCT BY ANOTHER MANUFACTURER.
2X10 TREATED WOOD, ANCHOR
TO TOP OF WALL W/ 1/4" CTRSNK
SELF TAPPING CONC. SCREW W/
1-3/4" MIN. EMBEDMENT. SPACE
@ 2'-0" C/C MAX.
CHAMFER EDGE
OF WOOD 3/4"
MEMBRANE FLASHING
TO EXTEND UP, OVER,
AND DOWN THE
FRONT OF THE TRT.
WOOD TOP PLATE
PROVIDE:
4" WIDE CONCEALED
SPLICE PLATE AT
EACH JOINT
EXIST. BRICK
PARAPET WALL
STRIP-IN MEMBRANE FLASHING
FIELD CRIMP
METAL FASCIA COVER
OVER 24 GA. STEEL
WATERDAM
1-1/4" RING SHANK NAILS
@ 12" C/C
EX. ROOF DECK
NEW ROOF INSUL.
NEW ROOFING
MEMBRANE
MANUF. STANDARD
BASE FLASHING DETAIL
A T
H
IG
H R
O O
F
V A R
IE
S
A T
LO
W
R O
O F
SEALANT
TERMINATION BAR W/
DRIVE PINE @ 12" C/C
MAX.
MEMBRANE FLASHING
MANUF. STANDARD
BASE FLASHING DETAIL
MEMBRANE ROOFING
M
IN
IM
U
M
/1
NEW ROOF
INSULATION
EX. ROOF DECK
EXISTING MASONRY WALL
NOTE:
HEIGHT OF NEW FLASHING
IS TO EXCEED THE HEIGHT
OF THE EXISTING
FLASHING BY A MIN. OF 1"
REMOVE THE EXISTING TERM. BAR
OR CUT OFF EXPOSED PORTION OF
CAP FLASHING
EXH. FAN OR VENTILATOR
1" WIDE SEAL STRIP
BY UNIT MANUFACTURER
CONTIN. METAL FLASHING
W/ DRIP. PROVIDE SEALANT
OVER NEOPRENE WASHER
AND SCREWHEAD
MEMBRANE FLASHING
MANUF. STANDARD BASE
FLASHING DETAIL
MEMBRANE
ROOFING SYSTEM
EX. ROOF DECK
EX. SUPPORT MEMBER
TO REMAIN
NOTE: ALL OTHER COUNTER
FLASHING FOR SPECIAL
CONDITIONS SHALL BE THE
RESPONSIBILITY OF THE
MECHANICAL CONTRACTOR
MIN. 2" THICK
INSULATED METAL
CURB W/ WOOD NAILER
BY MECH. CONTR.
O R S
PE
C
S
FO
R C
U R B
H T.
R
EF
ER
T
O M
EC
H
D
W G
S
EX. ROOF DECK
EX. MASONRY
PARAPET WALL
SEALANT
BORE HOLE THRU
WALL FOR NEW
6"⌀ GRAY PVC
PIPE - THROUGH
WALL SCUPPER MEMBRANE
FLASHING
THIS DIMENSION TO
BE 2" MAX. ABOVE
LOW POINT OF ROOF
MEMBRANE ROOF
ROOF INSULATION
SEALANT
X X X X X
X X X X X
STAINLESS STEEL
CLAMPING RING
WATER CUT-OFF
MASTIC
PRE-MOLDED PRESSURE-
SENSITIVE PIPE SEAL
EXISTING VENT PIPE OR
CONDUIT. EXTEND VENT PIPES
TO A MIN. OF 2'-6" ABOVE
NEW ROOF SURFACE
NEW ROOF INSULATION
EX. ROOF DECK
NEW EPDM
ROOFING
M
IN
'-0
M
A X.
FI
EL
D V
ER
IF
Y
R U
N G
S
"2
2' - 0"
1' - 8"
LOW ROOF
GALVANIZED
STEEL LADDERS
TOP OF PARAPET WALL8
" MASONRY WALL
BENT BAR 2-1/2" X 3/8"
LADDER SUPPORTS
AT 5'- 0" C/C MAX.
SHOP WELD TO STRINGERS
BOLT TO WALL WITH HILTI HIT
HY270 SYSTEM 5/8" Ø
THREADED ROD (EMBED 3-3/4")
BAR 2-1/2" X 1/2"
STRINGER
3/4"Ø REINF. BAR RUNG
PUNCH THROUGH AND
WELD TO BAR STRINGERS CLEAR
1' - 8"
4" 4"
NOTE:
EXTERIOR LADDERS TO BE GALVANIZED, SEE SPEC.
SECTION 055000. CLEAN OR GRIND OFF ANY ROUGH
AREAS OF THE STRINGERS AND RUNGS AFTER
GALVANIZING AND PAINT THESE AREAS WITH GALVANIZING
REPAIR PAINT.
BENT CHKRD PLATE 1/4"
SHOP WELD TO
BAR SUPPORTS
BAR 2-1/2" X 1/2" SUPPORT
TOP OF MASONRY
PARAPET WALL, FIELD VERIFY
THICKNESS
BAR 2-1/2" X
1/2" STRINGER
3/4" Ø REINF. BAR RUNG PUNCH
THROUGH AND WELD TO
BAR STRINGERS
BENT BAR 2-1/2" X 1/2"
LADDER SUPPORTS
SHOP WELD TO STRINGERS
SPA. @ 5'- 0" C/C MAX
BOLT TO WALL WITH HILTI HIT
HY270 SYSTEM 5/8" Ø
THREADED ROD (EMBED 3-3/4")
" 2
/2
NOTE:
LADDER TO BE GALVANIZED, SEE SPEC. SECTION 055000.
4" +/- 1' - 4" 4"
A
PP
R O
X.
ROOF
WALL THICKNESS
PLUS 8"
ROOF DRAIN DOME
& ASSEMBLY
MEMBRANE ROOFING
EXTEND INTO BOWL
1/2" MIN.
TAPERED ROOF
INSULATION
DECK CLAMP BY
BY DRAIN MFGR.,
INSTALL IN CIRCULAR
CUT-OUT IN ROOF
DECK
WRAP W/ INSULATION
ROOF DRAIN LEADER
SEE PLUMBING DWGS.
ROOF DECK
FLASHING RING
& GRAVEL STOP
EX. STEEL STAIR
ORIGINAL
BUILDING
(NO WORK)
ONE STORY BUILDING
TWO STORY BUILDING
NEW RD
NEW RD
NEW RD
NEW RD
NEW RD
NOTES:
REMOVE PORTION OF THE EX. PLASTER
CEILINGS AS REQUIRED TO INSTALL NEW
ROOF DRAIN PIPING, SEE MECH. DWGS..
PATCH CEILING WITH 5/8" TYPE 'X' MOISTURE
RESISTANT GYPSUM BD. WITH A LEVEL ONE
FINISH.
EXISTING ROOF DRAIN PIPING HAS INSULATION
THAT MAY CONTAIN HAZARDOUS MATERIALS.
REFER TO SPEC. SECTION 024119 SELECTIVE
DEMOLITION.
p.304.345.1060 f 304.345.3693 www.wsgarch.com
Charleston, WV 25302 717 Bigley Avenue
WILLIAMSON SHRIVER ARCHITECTS
p.412.931.8888 f.412.939.2525 www.tower-engineering.com
REENIGNE NI G
W ill ia m so n
Sh ri ve r
A rc hi te ct s, In c.
a nd a s
Po st ed o n Pr oj ec t M an ag em en t So ft w ar e
C drawn by checked by date comm #
Ow ne r:
W es t V irg in ia
S ch oo l f or th e D ea f a nd B lin d
W es t V irg in ia
B oa rd o f E du ca tio n
Roof Plan and Details dks
GIM
2026-068 May 29, 2026
Ro of
R ep la ce m en t a t t he E le m en ta ry D or m
W in g
A-100
Ch ar les to n, W es t V irg in a
C on st ru ct io n D oc um en ts
Ro m ne y, W es t V irg in ia
Scale: 1/8" = 1'-0" Roof Plan
DETAIL
SCALE: A-1001 1/2" = 1'-0"
TYPICAL ROOF EDGE - MASONRY PARAPET WALL
1 DETAIL
SCALE: A-1003" = 1'-0"
ROOF FLASHING AT EXISTING WALL.
2 DETAIL
SCALE: A-1001 1/2" = 1'-0"
EXH. FAN OR VENTILATOR CURB
DETAIL
SCALE: A-1001 1/2" = 1'-0"
OVERFLOW SCUPPER
5 DETAIL
SCALE: A-1001 1/2" = 1'-0"
VENT PIPE FLASHING
DETAIL
SCALE: A-1001/4" = 1'-0"
LADDER TYPES
7 DETAIL
SCALE: A-1001 1/2" = 1'-0"
TYPICAL STEEL ROOF LADDER - PLAN
DETAIL
SCALE: A-1003/4" = 1'-0"
TYPICAL STEEL ROOF LADDER - SECTION
DETAIL
SCALE: A-1001 1/2" = 1'-0"
TYPICAL ROOF DRAIN
Scale: 1/16" = 1'-0" Reflected Ceiling Plan
E X
IS
T
IN
G R
O O
F T
O R
E M
A
IN
N E W
R O
O F p.304.345.1060 f 304.345.3693 www.wsgarch.com
Charleston, WV 25302 717 Bigley Avenue
WILLIAMSON SHRIVER ARCHITECTS
p.412.931.8888 f.412.939.2525 www.tower-engineering.com
REENIGNE NI G
W ill ia m s o n
S h ri v e r
A rc h it e c ts
In c a n d a s P o s te d o n P ro je c t
M a n a g e m e n t S o ft w a re
C drawn by checked by date comm #
O w n er
W es t V ir g in ia
S ch o o l f o r th e D ea f an d
B lin d
W es t V ir g in ia
B o ar d o f
E d u ca ti o n
Lightning Protection Plan
JM
NK
2026-086
May 29, 2026
R o o f
R ep la ce m en t at t h e E le m en ta ry D o rm
W in g
LP-100
C h ar le st o n
W es t V ir g in a
C o n st ru ct io n
D o cu m en ts
R o m n ey , W es t
V ir gi n ia
Scale: 1/8" = 1'-0" Roof Plan - Lightning Protection
GENERAL NOTES (THIS SHEET)
REMOVE EXISTING LIGHTNING PROTECTION AIR TERMINALS,
COMPONENTS, AND CONDUCTORS ONLY WITHIN ROOF AREAS
DESIGNATED TO BE REPLACED. PROTECT, MAINTAIN, AND KEEP
IN SERVICE THE EXISTING LIGHTNING PROTECTION SYSTEM AT
ROOF AREAS NOT BEING MODIFIED.
PROVIDE A NEW LIGHTNING PROTECTION SYSTEM FOR ALL
REPLACED ROOF AREAS IN ACCORDANCE WITH SPECIFICATION
SECTION 264113. CONNECT THE NEW LIGHTNING PROTECTION
SYSTEM TO THE EXISTING SYSTEM AT THE LIMITS OF ROOF
REPLACEMENT TO PROVIDE A COMPLETE, CONTINUOUS
LIGHTNING PROTECTION SYSTEM FOR THE ENTIRE BUILDING.
PROVIDE LISTED CONNECTIONS COMPATIBLE WITH THE
MATERIALS OF THE EXISTING AND NEW SYSTEMS.
AT A MINIMUM, THE NEW LIGHTNING PROTECTION SYSTEM
SHALL INCLUDE THE FOLLOWING:
a. AIR TERMINALS IN ACCORDANCE WITH DETAIL 1/LP-101
LOCATED ALONG THE PARAPET WALLS A MAXIMUM OF
20'-0" ON CENTER. PROVIDE 24 STRAND, 14 GAUGE
ALUMINUM COPPER BETWEEN EACH AIR TERMINAL.
b. PROVIDE 24 STRAND, 14 GAUGE BARE ALUMINUM
CONDUCTOR ACROSS LONGEST DIMENSION OF FLAT
ROOF(S) IN ACCORDANCE WITH DETAIL 1/LP-101. PROVIDE
ADHESIVE PADS TO SECURE CABLING TO ROOF. PROVIDE
AIR TERMINALS LOCATED EVERY 20'-0" ALONG LENGTH OF
CONDUCTOR AND ROUTE CONDUCTOR THROUGH EACH AIR
TERMINAL MOUNTING PLATE.
c. BOND ALL ROOF-MOUNTED HVAC EQUIPMENT IN
ACCORDANCE WITH DETAIL 1/LP-101.
d. PROVIDE DOWNLEADS TO GROUND IN ACCORDANCE WITH
THE SPECIFICATIONS AND DETAILS 1/LP-101.
e. PROVIDE DOWNLEADS BETWEEN DIFFERENT ROOF
ELEVATIONS IN ACCORDANCE WITH THE SPECIFICATIONS
AND DETAIL 1/LP-101.
CODED NOTES - SHEET LP-100
1 LOCATION OF EXISTING LIGHTNING PROTECTION SYSTEM DOWNLEAD FROM
EXISTING TO REMAIN ROOF (PROJECT WEST). TIE IN REPLACEMENT
LIGHTNING PROTECTION SYSTEM AT THIS LOCATION. DOWNLEADS FROM
EXISTING TO REMAIN ROOF SHALL BE REPLACED AND PROVIDED NEW.
ENCLOSE NEW DOWNLEAD CONDUCTOR IN 1” PVC CONDUIT IN
ACCORDANCE WITH DETAIL 1/LP-101.
NO. A166: ALUMINUM
LOOP CABLE HOLDER
AT 3'-0" ON CENTER
NO. A55BT: 1/2" X 12"
SOLID ALUMINUM BLUNT
TIP AIR TERMINAL
NO. A690X: PARAPET MOUNT
ALUMINUM POINT BASE
-OR-
NO. A678LA: RIGHT ANGLE BASE
WHERE PARAPET CAP IS WIDER THAN
PARAPET WALL.
NO. A24: 24 STRANDS X 14
GAUGE BARE ALUMINUM
CONDUCTOR
AIR TERMINAL - PARAPET
NO. A55BT: 1/2" X 12" SOLID
ALUMINUM BLUNT TIP AIR TERMINAL
NO. A688: ADHESIVE FLAT
MOUNT POINT BASE
-OR-
NO. A30: FLAT MOUNT POINT
BASE WITH SWIVEL ADAPTER FOR
SLOPED ROOF.
NO. A24: 24 STRANDS X 14
GAUGE BARE ALUMINUM
CONDUCTOR
NO. A730: ADHESIVE CABLE
HOLDER AT 3'-0" ON CENTER
AIR TERMINAL - ROOF EDGE (NO PARAPET), FLAT ROOF, SLOPED ROOF
NO. A55BT: 1/2" X 12"
SOLID ALUMINUM BLUNT
TIP AIR TERMINAL
NO. A690: VERTICAL
MOUNT POINT BASE
NO. A24: 24 STRANDS X
14 GAUGE BARE
ALUMINUM CONDUCTOR
AIR TERMINAL - VENT PIPE
NO. A611: FLAT MOUNT
ALUMINUM POINT BASE
NO. A24: 24 STRANDS X 14 GAUGE
BARE ALUMINUM CONDUCTOR
NO A423: CAST ALUMINUM
PARALLEL CABLE SPLICER
NO. A702: BOND PLATE
NO. A76M: MECHANICAL EQUIPMENT
ALUMINUM POINT BASE
NO. A55BT: 1/2" X12" SOLID
ALUMINUM BLUNT TIP AIR TERMINAL
NO. A55BT: 1/2" X12" SOLID
ALUMINUM BLUNT TIP AIR TERMINAL
HVAC EQUIPMENT BONDING
1/2" STAINLESS STEEL RISER
1/2" STAINLESS STEEL NUT AND WASHER
NO. 155: BI-METAL TRANSITIONAL
FITTING (THRU-ROOF CONNECTOR)
1" PVC PIPE CAP
FINAL ROOF FLASHING BY
ROOFING CONTRACTOR
1" PVC SLEEVE
NO. A24: 24 STRANDS X 14 GAUGE
BARE ALUMINUM CONDUCTOR
8" MAX.
NO. A29: 29 STRANDS
X 17 GAUGE BARE
COPPER CONDUCTOR
THROUGH-ROOF CONNECTOR
1" PVC CONDUIT
REFER TO THRU-ROOF DETAIL
SEE AIR TERMINAL - PARAPET DETAIL
PROVIDE WIRE IN 1" PVC CONDUIT
SEE GROUND
ROD DETAIL
2' MIN.
NO. A24: 24 STRANDS X 14 GAUGE BARE ALUMINUM CONDUCTOR
REFER TO THRU-ROOF CONNECTOR
DETAIL
WHERE STEEL COLUMN IS NOT
AVAILABLE FOR USE AS A DOWN
CONDUCTOR, PROVIDE NO. 29X
COPPER WIRE IN 1" PVC CONDUIT
WHERE STEEL COLUMN CAN BE USED AS
DOWN CONDUCTOR, BOND COPPER WIRE
TO STEEL BEAM WITH NO. A701XS C-
CLAMP TYPE BONDING PLATE
NO. 29X: 29 STRANDS X 17
GAUGE BARE COPPER WIRE
SEE AIR TERMINAL - PARAPET DETAIL
PROVIDE CONNECTION TO UPPER
ROOF (WHERE APPLICABLE)
WHERE STEEL COLUMN CAN BE USED AS
DOWN CONDUCTOR, CADWELD COPPER
WIRE TO STEEL BEAM, CADWELD VBC2Q
STUB CONDUIT OUT AT ROOF LEVEL
NO. A24: 24 STRANDS X 14 GAUGE BARE ALUMINUM CONDUCTOR
ROUTE WIRE IN 1" PVC CONDUIT
STUB CONDUIT OUT
AT ROOF LEVEL
ROUTE CONDUIT INSIDE OF SLOPED
ROOF (WHERE APPLICABLE)
DOWNLEADS (TO LOWER ROOF AND TO GROUND)
STEEL COLUMN
CADWELD VBC2Q CABLE TO STEEL
CONNECTION. INSTALLATION SHALL BE
AS REQUIRED BY THE MANUFACTURER.
CADWELD PCC2Q2Q CABLE TO CABLE
CONNECTION. INSTALLATION SHALL BE AS
REQUIRED BY THE MANUFACTURER.
36" MIN.
CADWELD FITTING -
INSTALLATION
SHALL BE AS
REQUIRED BY THE
MANUFACTURER.
3/4" COPPER GROUND ROD MINIMUM 10' LENGTH, LONGER AS REQUIRED
TO HAVE BOTTOM OF ROD BELOW BOTTOM OF FOOTER
FINISHED GRADE
FOOTER
#4/0 AWG BARE COPPER PIGTAIL TO STEEL COLUMN
#4/0 AWG BARE 19-STRAND CONDUCTOR
OUTBOARD OF FOUNDATION
GROUND ROD
GENERAL NOTES - LIGHTNING PROTECTION SYSTEM
A. PROVIDE A NEW LIGHTNING PROTECTION SYSTEM FOR ALL REPLACED ROOF AREAS IN ACCORDANCE WITH SPECIFICATION SECTION 264113. CONNECT THE NEW LIGHTNING PROTECTION SYSTEM TO THE EXISTING SYSTEM AT THE LIMITS OF ROOF REPLACEMENT TO PROVIDE A COMPLETE, CONTINUOUS LIGHTNING PROTECTION SYSTEM FOR THE ENTIRE BUILDING.
PROVIDE LISTED CONNECTIONS COMPATIBLE WITH THE MATERIALS OF THE EXISTING AND NEW SYSTEMS.
B. ALL MODEL NUMBERS SHOWN ARE BASED ON THOMPSON LIGHTNING PROTECTION INC. REFER TO SPECIFICATION FOR
ACCEPTABLE ALTERNATE MANUFACTURERS.
C. ALL MATERIAL TO BE UL APPROVED WITH LABELS ON CONDUCTORS AT 10'-0" INTERVALS AND LABELS ON ALL AIR
TERMINALS.
D. MAINTAIN HORIZONTAL OR DOWNWARD COURSING OF MAIN CONDUCTOR AND ENSURE THAT ALL BENDS HAVE AT LEAST AN
8" RADIUS AND DO NOT EXCEED 90 DEGREES.
E. ATTACH ALL EXPOSED ROOF, DOWN LEAD AND BONDING CABLES AT 3'-0" ON CENTER MAXIMUM.
F. INSTALLATION IS BASED UPON ALL ROOF-MOUNTED LIGHTNING PROTECTION EQUIPMENT BEING ADHERED DIRECTORY TO
ROOF SURFACE. VERIFY COMPATIBILITY OF ADHESIVE ON MEMBRANE ROOF APPLICATIONS WITH ROOFING INSTALLER PRIOR
TO INSTALLATION.
G. LIGHTNING PROTECTION COMPONENT MATERIALS SHALL BE GALVANICALLY COMPATIBLE WITH METAL COPING. VERIFY WITH
ARCHITECT. SEAL METAL COPING PENETRATIONS WITH SILICONE SEALANT.
H. BOND TO WATER SERVICE AND OTHER PIPING SYSTEMS AS SHOWN AND AS REQUIRED BY CODES.
I. INTERCONNECT LIGHTNING PROTECTION GROUND TO ELECTRIC, TELEPHONE, AND OTHER BUILDING GROUND SYSTEMS AS
SHOWN OR AS REQUIRED BY CODE.
J. "AS -BUILT" DRAWINGS SHALL BE SUBMITTED IN ACCORDANCE WITH CERTIFICATION PROCEDURES.
K. COMPLETED INSTALLATION AS SHOWN SHALL BEAR UL MASTER LABEL, SECURED BY SYSTEM INSTALLER PER UL96A.
L. INSTALLATION SHALL COMPLY IN ALL RESPECTS TO LPI CODE 175. INSTALLATION SHALL BE MADE BY OR UNDER THE
SUPERVISION OF AN LPI CERTIFIED MASTER INSTALLER. COMPLETED INSTALLATION TO RECEIVE SYSTEM CERTIFICATION
INCLUDING SUBMITTAL OF FORM LPI-1-R91.
M. AT A MINIMUM, THE COMPLETE LIGHTNING PROTECTION SYSTEM SHALL INCLUDE THE FOLLOWING:
1. AIR TERMINALS LOCATED ALONG THE PARAPET WALLS. AIR TEMINALS SHALL BE LOCATED A MAXIMUM OF 20'-0" ON
CENTER AND WITHIN 2'-0" OF OUTSIDE BUILDING EDGE AND OUTSIDE CORNERS. INSTALL WITH A MINIMUM PROJECTION OF 10" ABOVE OBJECT PROTECTED. PROVIDE 24 STRAND, 14 GAUGE BARE ALUMINUM CONDUCTOR ROUTED
CONTINOUSLY ALONG THE PARAPET WALL, THROUGH EACH AIR TERMINAL MOUNTING PLATE.
2. PROVIDE 24 STRAND, 14 GAUGE BARE ALUMINUM CONDUCTOR ACROSS LONGEST DIMENSION OF FLAT ROOF(S).
PROVIDE ADHESIVE PADS TO SECURE CABLING TO ROOF. PROVIDE AIR TERMINALS LOCATED EVERY 20'-0" ALONG LENGTH OF CONDUCTOR AND ROUTE CONDUCTOR THROUGH EACH AIR TERMINAL MOUNTING PLATE.
3. AIR TERMINALS ON ALL VENT PIPING.
4. BOND ALL ROOF-MOUNTED MECHANICAL EQUIPMENT. LIGHTNING PROTECTION SYSTEM MATERIALS AT MECHANICAL
EQUIPMENT MUST BE ALUMINUM TO ENSURE ELECTROLYTIC COMPATIBILITY AND CODE COMPLIANCE.
5. PROVIDE DOWNLEADS BETWEEN DIFFERENT ROOF ELEVATIONS AND DOWNLEADS TO GROUND. PROVIDE PENETRATIONS
THROUGH ROOF FOR LIGHTNING PROTECTION CABLE. WHERE APPLICABLE, BOND CABLE TO BUILDING STEEL BELOW
ROOF .
6. GROUND RODS - ALL GROUNDING CABLES SHALL BE #4/0 CONCENTRIC STRAND COPPER, 19 STRAND. HOLES SHALL BE CORE DRILLED THROUGH ROCK TO INSTALL GROUND RODS IF REQUIRED. WHERE OVER 10' IN LENGTH, GROUND RODS
SHALL BE SECTIONAL TYPE.
NO. A24: 24 STRANDS X 14 GAUGE
BARE ALUMINUM CONDUCTOR
NO. A24: 24 STRANDS X 14 GAUGE
BARE ALUMINUM CONDUCTOR
ROUTE WIRE IN 1" PVC CONDUIT, EXTEND
THROUGH FOUNDATION WALL TO EXTERIOR
OF BUILDNG
p.304.345.1060 f 304.345.3693 www.wsgarch.com
Charleston, WV 25302 717 Bigley Avenue
WILLIAMSON SHRIVER ARCHITECTS
p.412.931.8888 f.412.939.2525 www.tower-engineering.com
REENIGNE NI G
W ill ia m s o n
S h ri v e r
A rc h it e c ts
In c a n d a s P o s te d o n P ro je c t
M a n a g e m e n t S o ft w a re
C drawn by checked by date comm #
O w n er
W es t V ir g in ia
S ch o o l f o r th e D ea f an d
B lin d
W es t V ir g in ia
B o ar d o f
E d u ca ti o n
Lightning Protection Details
JM
NK
2026-086
May 29, 2026
R o o f
R ep la ce m en t at t h e E le m en ta ry D o rm
W in g
LP-101
C h ar le st o n
W es t V ir g in a
C o n st ru ct io n
D o cu m en ts
R o m n ey , W es t
V ir gi n ia
SCALE:
LP-101
NOT TO SCALE
LIGHTNING PROTECTION DETAILS 1
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R. EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
4" RD-1
(2039 SQ. FT.)
(85 GPM)
4" RD-1
(2285 SQ. FT.)
(95 GPM)
4" RD-1
(2276 SQ. FT.)
(95 GPM)
4" RD-1
(2056 SQ. FT.)
(86 GPM)
4" RD-1
(1031 SQ. FT.)
(43 GPM)
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R. EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
EXISTING
V.T.R.
A. THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY
FITTINGS AS REQUIRED BY ALL APPLICABLE CODES AND GOVERNING AUTHORITIES.
B. THE PLUMBING CONTRACTOR SHALL VERIFY AND CORRECT, AS REQUIRED TO MEET ALL
CODES AND REGULATIONS, ANY AND ALL POSSIBLE DISCREPANCIES BETWEEN TYPE AND
SIZE OF CONNECTIONS SPECIFIED IN THE PLUMBING FIXTURE SCHEDULES AND FIXTURES
ACTUALLY INSTALLED.
C. VALVES AND FITTING SHALL BE OF THE SAME SIZE AS THE PIPING OF WHICH THEY ARE
INSTALLED.
D. THE DRAWINGS ARE DIAGRAMMATIC, THE CONTRACTOR SHALL VERIFY ACTUAL
CONDITIONS AT THE SITE PRIOR TO ANY INSTALLATION.
E. THE PLUMBING CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES AND
EXISTING CONDITIONS.
F. PLUMBING CONTRACTOR SHALL FIELD VERIFY ALL MEASUREMENTS PRIOR TO LAYING AND
CONNECTING ALL STORM PIPING AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES.
G. ALL PIPING SHALL BE INSTALLED AS CLOSE TO DRAWINGS AS POSSIBLE WITH NO
CHANGES IN SIZING.
H. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY
SUPPORTING DEVICES FOR ALL FIXTURES INCLUDED IN THE CONTRACT DRAWINGS AND
AS SPECIFIED.
I. PLUMBING CONTRACTOR SHALL GIVE SUITABLE NOTICE TO ALL APPLICABLE UTILITY
COMPANIES AND OWNER PRIOR TO PERFORMING WORK INVOLVING UTILITIES.
J. ALL PIPING SHALL BE ROUTED CONCEALED ABOVE CEILINGS, WITHIN WALLS OR IN
CHASES EXCEPT FINAL CONNECTIONS TO FIXTURES, OR IN MECHANICAL ROOMS AND AS
SPECIFICALLY NOTED OTHERWISE.
K. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT PLUMBING FIXTURE LOCATIONS,
MOUNTING HEIGHTS AND DIMENSIONS.
L. ALL VENTS THROUGH ROOF SHALL BE A MINIMUM OF FIFTEEN (15) FEET FROM
MECHANICAL ROOFTOP AIR INTAKES.
M. PLUMBING CONTRACTOR SHALL SUBMIT SHOP DRAWINGS (INCLUDING PIPE ROUTING AND
EQUIPMENT LOCATIONS) TO ARCHITECT/ENGINEER FOR REVIEW PRIOR TO THE
INSTALLATION OR PURCHASING OF ANY PIPING AND/OR EQUIPMENT.
N. THE PLUMBING CONTRACTOR SHALL BASE HIS/HER PROPOSAL UPON THE EQUIPMENT,
FIXTURES, ETC. SCHEDULED OR SPECIFIED, USING THE MANUFACTURERS AND MODEL
NUMBERS AS CALLED FOR IN THE SPECIFICATIONS AND SCHEDULED ON THE DRAWINGS.
IF MORE THAN ONE MANUFACTURER IS SPECIFIED, ANY ONE OF THE MANUFACTURERS
MAY BE USED IN THE PROPOSAL. IF THE CONTRACTOR WISHES TO USE EQUIPMENT,
FIXTURES, ETC. NOT SPECIFIED, HE MUST SUBMIT ON LETTERHEAD STATIONERY, THE
EQUIPMENT, FIXTURES, ETC. SUBSTITUTED AND RECEIVE ARCHITECT/ENGINEER
APPROVAL 10 DAYS BEFORE THE BID IS DUE.
O. PLUMBING CONTRACTOR SHALL PROVIDE ALL PLUMBING COMPONENTS OF A SIMILAR
TYPE BY ONE MANUFACTURER TO ENSURE SYSTEM INTEGRITY AND SIMPLIFIED
MAINTENANCE.
P. THE PLUMBING CONTRACTOR SHALL ORDER ALL MATERIALS IN SUFFICIENT TIME TO
AVOID DELAYING THE COMPLETION OF THE PROJECT. DELAY IN DELIVERIES WILL NOT BE
CONSIDERED A JUSTIFIABLE REASON FOR SUBMISSION OF SUBSTITUTE MATERIALS.
Q. PIPING SHALL NOT PENETRATE ANY WALL FOOTINGS, COORDINATE WITH GENERAL
CONTRACTOR TO DROP FOOTINGS AS REQUIRED TO CLEAR PLUMBING SERVICES WHERE
ABSOLUTELY NECESSARY. PIPING PENETRATING A BEARING WALL OR FOOTING MUST BE
SLEEVED AND THE LOCATION BE APPROVED BY THE STRUCTURAL ENGINEER.
R. ALL PIPING IS ABOVE THE CEILING UNLESS OTHERWISE NOTED.
S. PROVIDE SLEEVES AND FIRE STOP SEALANTS AT ALL PIPE PENETRATIONS THROUGH FIRE
RATED FLOORS AND WALLS. COMPLY WITH ASTM E-814 AND UL 1479.
MECHANICAL GENERAL NOTES
A. COORDINATE DEMOLITION WORK WITH OTHER TRADES AND EXISTING CONDITIONS.
B. THE DRAWINGS ARE DIAGRAMMATIC. VERIFY ACTUAL CONDITIONS AT THE SITE BEFORE
PROCEEDING WITH WORK.
C. OWNER RETAINS THE RIGHTS TO ALL ITEMS AND EQUIPMENT SCHEDULED FOR REMOVAL.
D. COORDINATE STAGING OF DEMOLITION AND NEW CONSTRUCTION TO AVOID
INTERRUPTION OF BUILDING UTILITIES AND SERVICES.
E. DISCONNECT AND REMOVE FIXTURES, PIPING, AND EQUIPMENT TO ACCOMPLISH
DEMOLITION SHOWN. SALVAGED ITEMS NOT SCHEDULED FOR REUSE ARE TO BE TURNED
OVER TO THE OWNER.
F. COORDINATE DEMOLITION DRAWINGS WITH FLOOR PLANS FOR CONNECTION LOCATIONS
OF NEW WORK WITH EXISTING SYSTEMS.
G. FIXTURES, PIPING AND EQUIPMENT WITHIN THE CONSTRUCTION AREAS NOT AFFECTED BY
THE WORK OF THIS CONTRACT SHALL BE PROTECTED PRIOR TO COMMENCEMENT AND
UNTIL THE COMPLETION OF THE WORK.
H. PROTECT (OR REMOVE AND STORE) EXISTING FIXTURES, FITTINGS, AND EQUIPMENT TO
BE REUSED OR RELOCATED, THROUGH OUT ALL STAGES OF DEMOLITION AND
CONSTRUCTION. REINSTALL AS INDICATED ON FLOOR PLANS.
I. REFER TO CODED NOTES FOR ADDITIONAL INFORMATION FOR DEMOLITION WORK.
MECHANICAL DEMOLITION NOTES
MECHANICAL PIPING LEGEND
DROP/RISE POINT OF CONNECTION
FLOW DIRECTION
BREAK/CONTINUATION # NEW WORK CODED NOTE
DEMOLITION LIMIT
# DEMOLITION CODED NOTE
VENT THRU ROOFV.T.R.
RAIN WATER CONDUCTOR
MECHANICAL PIPING LEGEND
RWC
DEMOLISHED PIPING
EXISTING PIPING
p.304.345.1060 f 304.345.3693 www.wsgarch.com
Charleston, WV 25302 717 Bigley Avenue
WILLIAMSON SHRIVER ARCHITECTS
p.412.931.8888 f.412.939.2525 www.tower-engineering.com
REENIGNE NI G
W ill ia m s o n
S h ri v e r
A rc h it e c ts
In c a n d a s P o s te d o n P ro je c t
M a n a g e m e n t S o ft w a re
C drawn by checked by date comm #
O w n er
W es t V ir g in ia
S ch o o l f o r th e D ea f an d
B lin d
W es t V ir g in ia
B o ar d o f
E d u ca ti o n
Mechanical Roof Plan and Details
SMK
TRZ
2026-086
May 29, 2026
R o o f
R ep la ce m en t at t h e E le m en ta ry D o rm
W in g
M-100
C h ar le st o n
W es t V ir g in a
C o n st ru ct io n
D o cu m en ts
R o m n ey , W es t
V ir gi n ia
Scale: 1/8" = 1'-0" Roof Plan - Mechanical New Work
Scale: 1/8" = 1'-0" Roof Plan - Mechanical Demo Work
NEW WORK CODED NOTES - M-100
1 INSTALL NEW 4" ROOF DRAIN AND 4" RAIN WATER CONDUCTOR PIPING
BACK TO VERTICAL STACK. CONVERT 4" RAIN WATER CONDUCTOR TO
EXISTING VERTICAL RAINWATER CONDUCTOR. PATCH AND REPAIR
CHASE WALL TO MATCH EXISTING. FIELD VERIFY EXISTING SIZE AND
LOCATION.
2 EXISTING VENT THRU ROOF TO REMAIN. EXTEND VENT PIPING AS
NEEDED TO ACCOMODATE NEW ROOF MEMBRANE AND INSULATION
THICKNESS. REFER TO DETAIL 1 ON THIS SHEET FOR ADDITIONAL
INFORMATION.
3 INSTALL NEW 4" ROOF DRAIN AND 4" RAIN WATER CONDUCTOR PIPING
AND 5' OF VERTICAL RAINWATER CONDUCTOR PIPING. CONVERT 4"
RAIN WATER CONDUCTOR TO EXISTING VERTICAL RAINWATER
CONDUCTOR. PATCH AND REPAIR BULKHEAD AND CEILING TO MATCH
EXISTING. FIELD VERIFY EXISTING SIZE AND LOCATION.
DEMOLITION CODED NOTES - M-100
1 REMOVE EXISTING 4" ROOF DRAIN, ALL APPURTENACES, AND RAIN WATER
CONDUCTOR PIPING BACK TO VERTICAL STACK. FIELD VERIFY EXISTING SIZE
AND LOCATION.
2 REMOVE EXISTING 4" ROOF DRAIN, ALL APPURTENACES, AND RAIN WATER
CONDUCTOR PIPING BACK TO 5' BELOW ROOF DECK. FIELD VERIFY EXISTING
SIZE AND LOCATION.
3 REMOVE EXISTING VENTILATOR AND ASSOCIATED ROOF CURB. DISCONNECT
AND REMOVE ANY CONNECTED DUCTWORK AND CAP BELOW ROOF LEVEL WITH
INSULATED SHEET METAL. GC SHALL OWN ALL PATCHING AND ROOF WORK AT
AREA WHERE EXISTING VENTILATOR WAS REMOVED.
| Cover Sheet |
| Sheets |
| A-000 - Coversheet |
| A-100 Roof Plan and Details |
| Sheets |
| A-100 - Roof Plan and Details |
| 2026.06.22 - WVSDB - Elementary Roof Replacement - Bid Documents - Mechanical and Lightning Protection Drawings |
| Sheets |
| LP-100 - Lightning Protection Plan |
| LP-101 - Lightning Protection Details |
| M-100 - Mechanical Roof Plan and Details |
File details come from the government source that posted it. Updated .