This document is a National Park Service (NPS) / Alaska Region (AKRO) Fire Sprinkler System Inspection and Test Report form designed to comprehensively document fire sprinkler system safety and functionality. The four-page form covers multiple critical inspection areas including sprinkler coverage, heads, flow tests, alarms, valves, gauges, fire department connections, system-specific elements (dry pipe, preaction), and pressurized water storage tanks. The form requires detailed documentation of system status across 41 specific inspection points, with options to mark compliance as "Yes", "No", or "N/A", and provides space to record any identified deficiencies, their locations, recommended resolutions, and relevant NFPA (National Fire Protection Association) references. The form is intended to ensure thorough evaluation of fire protection systems according to NFPA 25 and NFPA 13 standards, with a focus on functional operation, maintenance, and potential safety improvements.
View the file
Other files for this federal contract opportunity
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fire Sprinklers Page 1 of 4
National Park Service / AKRO Inspection and Test Report (complete a separate form for each system)
FIRE SPRINKLER SYSTEM – DRY PIPE WET PIPE PREACTION RESIDENTIAL
Park Alpha Code: ________
Location Description : ______________________
Date of Test:_________________________ Time:_________________
Riser Valve Make: ______________________ Valve Model: _____________________ Size: ____________________ Serial No: _____________________
Off Site Monitoring? Yes No Monitoring Company or Location
Name ________________________________
DEFICIENCIES FOUND? Yes No List items that were not corrected. Use the Deficiencies section or attach itemized sheet
REPAIRS: All deficiencies have been corrected N/A Yes No
This certifies that the fire and life safety system has been inspected and tested for functional operation in accordance with the current edition of NFPA 25 and NFPA 13, and has been properly tagged and/or labeled. Any discrepancies found are noted in this report with code references for corrective action by the Owner/Responsible Person.
Technician Name (printed): ______________________ Company: ______________________________
Signature: ___________________________________ Phone #: _______________________________
State Certification No.: _________________________
National/NICET No.: ___________________________
GENERAL
1. Sprinkler coverage was inspected and is adequate Yes No
2. Sprinkler heads are not blocked or obstructed Yes No
3. Piping is adequately installed with no bent or visibly damaged piping Yes No
4. Hangars and bracing components are not missing or damaged Yes No
5. A backflow preventer is provided and is accessible for maintenance N/A Yes No
6. Sprinkler heads are provided 18” min. clearance above top of storage N/A Yes No
7. Hydraulic design placard is installed and visible on riser N/A Yes No
SPRINKLER HEADS
8. Number of Sprinkler Heads: <20 >20 but < 100 >100
9. All accessible sprinkler heads have been visually inspected and are free of corrosion, paint, obstructions and/or physical damage. (If “no”, list the location of any defective heads in the “Deficiencies” section.)
Yes No
10. Standard Response sprinkler heads are less than 50 years old and do not require sample testing or replacement.
N/A Yes No
11. Fast Response sprinkler heads (quick response and residential) are less than 20 years old and do not require sample testing or replacement.
N/A Yes No
12. Dry type sprinkler heads are less than 10 years old and do not require sample testing or replacement
N/A Yes No
Karma Torres Text Box Asset No.:
Karma Torres Line
Karma Torres Snapshot
Karma Torres Line
Karma Torres Line
Fire Sprinklers Page 2 of 4
13. The proper number of spare sprinkler heads is available, with the proper wrenches for each, at the riser or another designated location.
Yes No
FLOW TESTS
14. The system main drain is the proper size and discharges to the exterior of the building.
Size of drain _______ Required size ________
Yes No
15. A Main Drain flow test was performed:
Static pressure ____ psi Flow pressure ____ psi Return to static pressure ____min/sec
Yes No
16. Flow from the inspector’s test valve activates the system alarms within 60 seconds. Yes No
ALARMS AND SUPERVISORY DEVICES
17. All supervisory and alarm devices [i.e. bell(s), flow switches, high/low air switches, valve tamper switches] function properly.
N/A Yes No
18. A water motor gong/bell is provided on the exterior of the building N/A Yes No
VALVES
19. All system supply and control valves are secured or supervised in the open position. Yes No
20. All supply valves have been lubricated (OS&Y valves) N/A Yes No
GAUGES
21. The maintenance on system gauges is up-to-date. Every 5 years, installed gauges shall be checked against (1) calibrated gauge to determine accuracy. If not within 3% of the calibrated gauge it should be replaced or recalibrated.
Due date for the next comparison test: ____________
Yes No
OBSTRUCTION INVESTIGATION
22. A 5-year obstruction investigation was performed per NFPA 25.
Date for next obstruction investigation _____________
Yes No
FIRE DEPARTMENT CONNECTIONS
23. The Fire Department Connection(s) (FDC) is clear of bushes, guards, or other debris and is visible from the fire access road
N/A Yes No
24. FDC inlets have protective caps or covers. (Note: If missing, the pipe shall be visually inspected for debris)
N/A Yes No
25. FDC inlets have at least 12” clearance for operating wrenches. N/A Yes No
ALARM MONITORING
26. All signals were received by the fire alarm system and the monitoring company.
N/A Yes No
DRY PIPE SYSTEM
27. The dry pipe valve was trip tested per NFPA 25. System tripped at _______ psi.
N/A Yes No
28. Water was discharged from the inspector’s test connection within 60 seconds of opening the test valve (“full trip test”). Must be performed every 3 years. Water delivery was _______ seconds, or Date of last full trip test:
N/A Yes No
29. Air compressor refills system in 30 minutes or less. N/A Yes No
30. The system’s low points were drained and the system was restored to service.
N/A Yes No
31. A quick opening device (QOD) is used (accelerator or exhauster) N/A Yes No
PREACTION SYSTEM
32. Heat actuation devices were functionally tested. N/A Yes No
ANTIFREEZE Record high and low point glycol readings at the bottom of page 3
Fire Sprinklers Page 3 of 4
33. Antifreeze solution has been inspected and checked N/A Yes No
34. Premixed antifreeze solution is used N/A Yes No
PRESSURIZED WATER STORAGE TANK
35. Water level is within the normal range Yes No
36. Heating system is functional N/A Yes No
37. Exterior inspection of tank structure, supports, vents, and outlets, shows no evidence of accelerated corrosion or damage.
Yes No
38. Interior inspection was performed and shows no evidence accelerated corrosion, pitting, debris, or biological growth. (required at 3 year intervals)
N/A Yes No
39. All supply valves are open Yes No
40. Air or nitrogen pressure and quantity is adequate N/A Yes No
RECALLS
41. The technician did not find recalled devices or equipment during the visual inspection.
Yes No
ANTIFREEZE: . . Glycol high point measurement . . Glycol low point measurement
. . Glycol freeze protection temperature in degrees F
Where glycol freeze protection is determined to be above -20 deg F, the contractor must contact the COR immediately following the site visit to determine whether a contract modification is required to refill the systems with an approved -25 deg F (or greater) NFPA product.
Fire Sprinklers Page 4 of 4
Deficiencies
Resolved
Location:
Deficiency:
Recommended Resolution:
NFPA 25 or NFPA 13 reference:
Resolved
Location:
Deficiency:
Recommended Resolution:
NFPA 25 or NFPA 13 reference:
Resolved
Location:
Deficiency:
Recommended Resolution:
NFPA 25 or NFPA 13 reference:
Resolved
Location:
Deficiency:
Recommended Resolution:
NFPA 25 or NFPA 13 reference:
Resolved
Location:
Deficiency:
Recommended Resolution:
NFPA 25 or NFPA 13 reference:
| AKRO Test Reports |
| Clean Agent or CO2 Test Report |
| Dry Chemical Test Report |
| Fire Alarm Test Report |
| Fire Pump Test Report |
| Fire Sprinkler - Test Report-rev1 |
| Kitchen Suppression Test Report |
| Text321: |
| Text323: |
| Text324: |
| Text325: |
| Text326: |
| Text327: |
| Text328: |
| Text329: |
| Text330: |
| Text331: |
| Text332: |
| Text333: |
| Text334: |
| Text335: |
| Text336: |
| Text337: |
| Check Box415: Off |
| Check Box416: Off |
| Check Box417: Off |
| Check Box418: Off |
| Check Box419: Off |
| Check Box420: Off |
| Check Box421: Off |
| Check Box422: Off |
| Check Box423: Off |
| Check Box424: Off |
| Check Box425: Off |
| Check Box426: Off |
| Check Box427: Off |
| Check Box428: Off |
| Check Box429: Off |
| Check Box430: Off |
| Check Box431: Off |
| Check Box432: Off |
| Check Box433: Off |
| Check Box434: Off |
| Check Box435: Off |
| Check Box436: Off |
| Check Box437: Off |
| Check Box438: Off |
| Check Box439: Off |
| Check Box440: Off |
| Check Box441: Off |
| Check Box442: Off |
| Check Box443: Off |
| Check Box444: Off |
| Check Box445: Off |
| Check Box446: Off |
| Check Box447: Off |
| Check Box448: Off |
| Check Box449: Off |
| Check Box450: Off |
| Check Box451: Off |
| Check Box452: Off |
| Check Box453: Off |
| Check Box454: Off |
| Check Box455: Off |
| Check Box456: Off |
| Check Box457: Off |
| Check Box458: Off |
| Check Box459: Off |
| Check Box460: Off |
| Check Box461: Off |
| Check Box462: Off |
| Check Box463: Off |
| Check Box464: Off |
| Check Box465: Off |
| Check Box466: Off |
| Check Box467: Off |
| Check Box468: Off |
| Check Box469: Off |
| Check Box470: Off |
| Check Box471: Off |
| Check Box472: Off |
| Check Box473: Off |
| Check Box474: Off |
| Check Box544: Off |
| Check Box545: Off |
| Check Box546: Off |
| Check Box547: Off |
| Check Box548: Off |
| Check Box549: Off |
| Check Box550: Off |
| Check Box551: Off |
| Check Box552: Off |
| Check Box553: Off |
| Check Box554: Off |
| Check Box555: Off |
| Check Box556: Off |
| Check Box557: Off |
| Check Box558: Off |
| Check Box559: Off |
| Check Box560: Off |
| Check Box561: Off |
| Check Box562: Off |
| Check Box563: Off |
| Check Box564: Off |
| Check Box565: Off |
| Check Box566: Off |
| Check Box567: Off |
| Check Box568: Off |
| Check Box569: Off |
| Check Box570: Off |
| Check Box571: Off |
| Check Box572: Off |
| Check Box573: Off |
| Check Box574: Off |
| Check Box575: Off |
| Check Box576: Off |
| Check Box577: Off |
| Check Box578: Off |
| Check Box579: Off |
| Check Box580: Off |
| Check Box581: Off |
| Check Box582: Off |
| Check Box583: Off |
| Check Box584: Off |
| Check Box585: Off |
| Check Box586: Off |
| Check Box587: Off |
| Check Box588: Off |
| Check Box589: Off |
| Check Box590: Off |
| Check Box591: Off |
| Check Box592: Off |
| Check Box593: Off |
| Check Box594: Off |
| Check Box595: Off |
| Check Box596: Off |
| Check Box597: Off |
| Check Box598: Off |
| Check Box599: Off |
| Check Box600: Off |
| Check Box601: Off |
| Check Box602: Off |
| Check Box603: Off |
| Check Box604: Off |
| Text338: |
| Text339: |
| Text340: |
| Text341: |
| Text342: |
| Text343: |
| Text344: |
| Text345: |
| Text346: |
| Check Box605: Off |
| Check Box606: Off |
| Check Box607: Off |
| Text347: |
| Text348: |
| Text349: |
| Text350: |
| Text351: |
| Text352: |
| Text353: |
| Text354: |
| Text355: |
| Text356: |
| Text357: |
| Text358: |
| Text359: |
| Text360: |
| Text361: |
File details come from the government source that posted it. Updated .