This solicitation requests quotes for haul out services for the historic steam tug Hercules. The National Park Service seeks a contractor to remove the vessel from the water, perform structural repairs and maintenance, and return it to the water. Work must be done in accordance with historic preservation standards and be completed by a small business. Quotes are due by August 8, 2022 and the period of performance will commence upon award. Evaluation criteria include technical approach, experience restoring historic vessels and implementing safety practices, past performance, personnel qualifications, and price.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT 3

TOMAC NDT Services, Inc. Report, 2001

ALAMEDA, CA

ULTRASONIC THICKNESS SURVEY

OF

HERCULES

DECEMBER 13, 2001

11642 KNOTT AVE. SUITE #4

GARDEN GROVE, CA 92841

TEL.# 1-800-273-6091

FAX.# 714-898-6172

Attachment 3

Page 1 of 9 TOMAC NDT Services, Inc. Report, 2001

Ultrasonic Technique Report Form

Customer:

BA YSWP & YA CHI CO

29QQ Main Street Alameda CA 94501

General Information

Part Name:

HE:BCWBS

Part or Weld Number:

Hull Plates As Directed

Pait Material:

Carbon Steel

Configurations To Be Examined:

Spot Check Ear Thickness On Hull Plates As Directed

Applicable Code or Standard:

Customer lnfn Only

Instrument Used:

Type Search Unit Used:

Q 25" Dia 5" Mhz Dual E:lement Transducers

Type Couplant Used: Celhdase

Sketch:

See attached drawing.

Tomac NDT Services, Jue.

11642 Knott A venue Suite #4

Garden Grove, CA 92841

714-892-998 I

Customer P. 0.:

Job Number:

TM No.: 12-E:1 to 12-E:6 Date: 12-11-200I

Description Of Calibration:

Q 10" Q W" & Q 50" Carbon Steel Calibration Black

Directions & Extent Of Scanning:

Spat Check Ear Thickneu On Hull Plates As Directed

Surface Preparation: �W�i�re�w�b�e�e�l _________ _

Surface Condition: uM:J..10_,,dJJ.e.,_r,..a...,te"--'---P.loJitJ,Jtzw·na;;g _______ _

Findings:

See attached drawingsfnr thickness readings

□ Accept D Reject

Customer infn

Technician: �B�ZJ,,.,m�n�. �P�a�r�r ______ __ Level: TT

Page 2 of 9 TOMAC NDT Services, Inc. Report, 2001

Ultrasonic Technique Report Form

Customer:

BA YSHTP & YA CHI CO

29QQ Main Street Alameda CA 94501

General Information

Part Name:

HERCULES

Part or Weld Number:

Hull Plates, Port & Starboard

Part Material:

Carbon Steel

Configurations To Be Examined:

Random Thickneu Readings Were Taken on Plates As Per Campany Representative

Applicable Code or Standard:

Customer Tnfn OnlJI

Instrument Used:

Type Search Unit Used:

Q 5" Dia 2 5" Mhz Dual Element Transducers

Type Couplant Used: Cellulose

Sketch:

See attached drawing.

Tomac NDT Sen,ices, Ille.

I 1642 Knott A venue Suite #4

Garden Grove, CA 92841

714-892-998 !

Customer P. 0.:

Job Number:

TM No.: 12-El to 12-E6 Date: 12-29-2001

Description Of Calibration:

Calibration block Q 50" Q 'W" & Q IQ"

Directions & Extent Of Scanning:

Random Thickness Readings Were Taken On Each Plate From The Tnside Of Vie Ship

Surface Preparation:

Surface Condition:

Findings:

See attached drawingsfnr thickness readings (some areas were inaccessable)

□ Accept D Reject

Customer infn

Technician: Terry Vasquez Level: TT

Page 3 of 9 TOMAC NDT Services, Inc. Report, 2001

HERCULES

STARBOARD SIDE

I I I I ft ft \ I �--

HERCULES

� 0

.281 .406 0.382

_ ..:3�3 ' _ -I 0259

.300 r;::l

.2� - - - - - L:=J 276

· .220

.304

.308

I

____________ J

---- .215 .239

.320 .306

.275

.277

.254

NOTES:

READINGS WERE TAKEN

ON THE EXTERIOR OF HULL.

BAYSHIP & YACHT CO.

ALAMEDA, CA

TECHB

R

YAN PARR I DATE: 12-13-2001 I T2-E1

sH1PNo. Tomac NOT Services, Inc.

HERCULES 11642 Knoll A1•- 'iuile #4 Tel.# (800)-273-6091 STARBOARD SIDE Garden Gr '2841 Fax.# (714)-B98-6172

Page 4 of 9 TOMAC NDT Services, Inc. Report, 2001 r, �

.407

I .361 l .320

.380 I .317 ____ __ _

NOTES:

READINGS WERE TAKEN 45

ON THE EXTERIOR OF HULL.

HERCULES

STARBOARD SIDE

( _JI

0 0

I

I

I

I

I

I

I

I

I

I

I

I

I

I

I

I

.355 I

I -1

L

I

.385 .385 -

_321 I

I I \

.387 _______ 3�------1-----���----

BAYSHIP & YACHT CO.

ALAMEDA, CA

301 TEC\RYAN PARR

DATE:

12-13-2001

TM:

12-E2 sH1PNo.

I Tomac NOT Services, Inc.

HERCULES 11642 Knott A • Suile #4 Tel., (800)-273-6091 STARBOARD SIDE Garden Gr� 1B41 Fax.• l!.!!l·898-6172

Page 5 of 9 TOMAC NDT Services, Inc. Report, 2001

.445

NOTES:

READINGS WERE TAKEN

ON THE EXTERIOR OF HULL.

HERCULES

STARBOARD SIDE

.489 i .413

.273

.500

75 70

.360

.350

D

.351

.389 .315

BAYSHIP & YACHT CO.

ALAMEDA, CA

TECH:

I

DATE:

I

TM:

BRYAN PARR 12-13-2001 12-E3

sHIPNo. Tomac NOT Services, Inc.

HERCULES 11642 Knott� .. - �uite #4 Tel.# (B00)-273-6091

STARBOARD SIDE Garden Gr 12041 Fax.# (714)-898-6172

Page 6 of 9 TOMAC NDT Services, Inc. Report, 2001

.328

PATCH

NOTES:

READINGS WERE TAKEN

ON THE INTERIOR OF HULL.

HERCULES

PORT SIDE

HERCULES

.355

.254

.440

.415

.296

.321

.248 .298

.325

.306 .310

.306 .237

.344

.326

.268 .265

.275 .308

PATCH

.321

.305 .270

.322

I .307

.368 I 1 .291 I

- - - - - - - - - - - - - - - J-�8�

BAYSHIP & YACHT CO.

__ AL.AMEDA, CA

TECH, DATE,

BRYAN PARR 12-13-2001 11M2-E4

sH1P NO. Tomac NOT Services, Inc.

HERCULES 11642 Knott 11° <iuite #4 Tel.# (800)-273•6091 PORT SIDE Ga,den G, 2841 Fax.# (714)-898-6172

Page 7 of 9 TOMAC NDT Services, Inc. Report, 2001

I I

.371

.367

NOTES:

READINGS WERE TAKEN

'ON THE INTERIOR OF HULL.

LJ

.454 .488

.416

.341

.358

.448

.384

.347

HERCULES

PORT SIDE

0 0

I

I

I

I

I

I

I

I .476

I .306

I

I

I

I

.364 .390 I

I .354 I

I

I I

.284 I

I

I!

.321

I

.312 0 .381

'7 .387 .352

.340 I .397

.305

X '

.338 .394

.379 .380

.346

I .395

.302 I -'-428[ - - - - - -

.395

.471

.351

.320

BAYSHIP & YACHT CO.

ALAMEDA, CA

TECH, DATEc

BRYAN PARR 12-13-2001

SHIP No. Tomac NDT Services, Inc.

HERCULES 11642 Knott '1""' 9.uite #4 Tel. ii (800)-273-6091

__________________ ,.__ _ _..P_,OR_,T;.;S .. ID_E ___ _._G_,a ... rde_,n ... G-f.rJ 2841 Fax.# (714)-898-6172

Page 8 of 9 TOMAC NDT Services, Inc. Report, 2001

.350

.344

.284

NOTES:

READINGS WERE TAKEN

• ON THE INTERIOR OF HULL.

D

.394 I

.334 .300

.340

□ .351 .344

___ PATCH

.296 .307

.383

.374

.320

.342

.308

.349 .314

.344

.352

HERCULES

PORT SIDE

D

BAYSHIP & YACHT CO.

ALAMEDA, CA

TECH: DATE: TM:

BRYAN PARR 12-13-2001 12-E6

sHrPNO. Tomac NOT Services, Inc.

HPEO

R

RCTUSLID

ES

E

11642 Knon • -;1e #4 Tel.# (800)-273-6091

------------------...l--�2.li!.l!!�--L:G�a!:;rd!::•n!.5G!::r� '641 Fax.# 714-898-6172

Page 9 of 9 TOMAC NDT Services, Inc. Report, 2001

File details come from the government source that posted it. Updated .