National Park Service | U.S. Department of the Interior
NPS UniGuide Sign Standards
Visitor Information Sign System VIS and Wayside Hardware Specification Manual
Office of NPS Identity | NPS UniGuide Sign Program
Center for Media Services | Harpers Ferry, WV 25425 www.hfc.nps.gov/uniguide | 304-535-4069
Revision 3 October 5, 2017
Attachment G
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 2Revision 3 October 5, 2017
Disclosure Statement NPS UniGuide Standards
This publication is an administrative document developed for the guidance of employees of the National Park Service, its contractors, cooperating partners, and federal and state government agencies.
The National Park Service assumes no responsibility for the interpretation or application of the standards and information contained in this manual by other than its own employees. The use of trade names, product specifications, identification of firms and corporations in no way constitutes an official endorsement or approval by the United States
Government of any product, process, or service to the exclusion of others that may be suitable.
This sign standards manual includes data that shall not be disclosed outside the government without permission and shall not be duplicated, used, or disclosed wholly, or in part, for any purpose other than as required by the planning, design, or fabrication of signs for the National Park Service.
This information is the sole property of the Government with unlimited rights in the usage thereof and cannot be copyrighted by private parties.
Disclosure Statement NPS UniGuide Standards
Overview
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 3Revision 3 October 5, 2017
Table of Contents
VIS System Overview 4
Section I - TrailSide Series (TS) 17
Section II - Wall Mount Series (WM) 20
Section III - Low Profile / Wayside Series (LP) 26
Section V - Upright Series (UP) 31
Section V - VIS Hardware Accessories 48
Section VI - VIS Fabrication Drawings 55
Section VII - Specifications 178
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 4Revision 3 October 5, 2017
VIS System Overview Introduction 5
VIS System Overview 6
VIS Hardware Assembly Series 7
VIS Hardware Base Material Options 8
VIS Hardware Mounting Options 9
VIS Panels 10
VIS Panel Sizes 11
VIS Hardware Assembly Codes 15
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 5Revision 3 October 5, 2017
Introduction
Overview
It is estimated that approximately 75% of all park signs fall into the Visitor Information (VIS) category. VIS Signs are designed to present information in a consistent, attractive, convenient, and flexible format. Such information may involve pedestrian or bicycle and (low–speed) motorist guidance, regulations, resource protection, instructions and general information, fee information, safety warnings, maps, and interpretation. VIS Signs may also be used to identify parks (or park areas, features, or facilities) when more monumental identification signs are not required.
The flexible system of post and frame hardware components may be configured in a variety of ways to hold modular sign panels and other accessories. VIS hardware is available in a range of durable materials to suit local conditions, all selected for vandal resistance, low maintenance, and long life–cycle performance.
Sign frames are designed to hold graphic panels made from a variety of materials including porcelain enamel, fiberglass embedment, polycarbonate embedment, high pressure laminate, digitally printed adhesive vinyl on aluminum substrates with protective overlaminates, or computer cut retro–reflective sheeting.
Besides supporting sign panels, VIS hardware is designed to accommodate a number of accessories including bulletin cases, brochure holders, and posting displays.
This manual provides details and information on the specification and fabrication of VIS hardware.
Signs are the most frequently used means of communicating with park visitors. The National Park Service UniGuide Sign Standards provide design and fabrication guidelines for a full range of park signs including Park Identity, Motorist Guidance and Visitor Information (VIS).
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 6Revision 3 October 5, 2017
Removable Capture Rail
Graphic Panel
Welded Frame System with Internal Structural Core Panel
Low Profile wayside Base (LP)
Upright Sign Base (UP)
Wall Mount (WM)
VIS System Overview
Overview
The VIS system consists of a welded frame and core panel that can be attached to posts to create
Low Profile wayside bases, Upright Sign Bases, or for Wall Mount displays. The system consists of an aluminum extrusion or a break–formed steel frame with an internal structural core panel. Sign frames are designed to capture the graphic panel on four sides and includes a secure, but removable, capture rail for ease in changing panels.
Accessories that can be attached to upright bases include bulletin cases, brochure holders, and miscellaneous post displays.
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 7Revision 3 October 5, 2017
VIS Hardware Assembly Series
Trail Sign, Low Profile, Upright, Inline and Kiosks
Scale: 1/2" = 1'-0"
Trail Sign, Low Profile, Upright, Inline and Kiosks
Scale: 1/2" = 1'-0"
Trail Sign, Low Profile, Upright, Inline and Kiosks
Scale: 1/2" = 1'-0"
Trail Sign, Low Profile, Upright, Inline and Kiosks
Scale: 1/2" = 1'-0"
Trail Sign, Low Profile, Upright, Inline and Kiosks
Scale: 1/2" = 1'-0"
Trail Sign, Low Profile, Upright, Inline and Kiosks
Scale: 1/2" = 1'-0" Trail Sign, Low Profile, Upright, Inline and Kiosks
Scale: 1/2" = 1'-0"
Trail Sign, Low Profile, Upright, Inline and Kiosks
Scale: 1/2" = 1'-0"
Overview
The chart to the right provides an overview of the base hardware available in the VIS system.
All VIS bases are available in a variety of material options including weathering steel, galvanized steel, and painted aluminum. Painted aluminum bases are available in three paint color finishes.
The material and finish appropriate for a specific base depends primarily on the sign’s purpose and its location. Weathering steel is an excellent choice for low maintenance in many forested and desert sites; galvanized steel is very durable in coastal and other salt–water and corosive environments; and painted aluminum may be a good choice for an urban environment.
Low to the ground, Trailsides are an excellent choice for plant ID markers, site markers, trail guides, and anywhere a small discreet sign is required.
Designed to stand vertically so they attract attention, Upright bases typically provide practical information to visitors rather than site–specific interpretation.
Like the Low Profile base, Upright bases are available in a variety of material finishes and sizes. Bases can be fabricated as a single unit, double or triple inline unit, and tri-sided and four–sided units. The single unit and inline bases can be configured for one or two-sided display. All of the uprights, (in certain preset sizes) are available with or without a roof structure.
Each base is designed to hold panels or other accessories including bulletin cases.
The Low Profile base is the preferred style for NPS interpretive outdoor exhibits. Available in a variety of material finishes and sizes the base’s simple, unadorned form makes it appropriate for any park landscape.
Wall Mount frames are designed to display information on vertical surfaces. Frames are available in a variety of materials and sizes.
TS Series - Trailsides UP Series - Uprights
Upright Base
Upright Tri (Tri-Side)
Upright Inline 2
Upright Quad (Four-Side)
Upright Inline 3
LP Series - Low Profile
WM Series - Wall Mount
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 8Revision 3 October 5, 2017
VIS Hardware Base Material Options
Overview
Weathering steel is an excellent material option for many NPS sites. Over time, with exposure to the elements, the bases turn a golden brown.
The bases are virtually mainternance free and do not require painting once installed.
Weathering steel bases can last well over 15 years.
Bases shipped are not pre weathered. When they arrive the bases are black and begin the weathering process when exposed to the elements.
Aluminum bases are a good all around choice for many NPS sites. Aluminum bases are primed and painted.
The bases are not maintenance free and do require occasional field cleaning and touch up to keep them looking good.
Aluminum bases are available in three standard paint colors.
All bases are painted with a coarse spatter coat finish for added durability.
Galvanized steel is an excellent choice for saltwater and other marine sites. Prior to final fabrication the base legs and frame are hot dipped galvanized which imparts a protective finish to the steel.
The bases are virtually mainternance free, show little if any sign of rust inhibition, and do not require painting once installed.
Galvanized steel bases can last well over 15 years.
When they arrive the bases have a shiny silver finish. Over time the bases patina to a dull grey.
Weathering Steel
Aluminum Standard Aluminum Paint Finish Colors
NPS Dark Brown
Matthews Paint
MP63856 with
Spatter Finish
NPS Medium Grey
Matthews Paint
MP63850 with
Spatter Finish
NPS Brown
Matthews Paint
MP63848 with
Spatter Finish
Galvanized Steel
VIS base hardware is available in three standard material options: weathering steel, galvanized steel, and painted aluminum. For painted aluminum bases there are three standard color choices.
Note: Colors shown are for representation only.
Actual color chips should be matched to the specification for accuracy.
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 9Revision 3 October 5, 2017
VIS Hardware Mounting Options
Overview
The chart to the right provides a basic overview of the hardware installation options available in the VIS system.
Refer to the fabrication details for more information.
Direct embedment is the typical mounting method for all VIS hardware. Post depth is typically 30" to 36" and posts are secured with concrete.
Stabilizer fins are another mounting accessory for direct embedment. Plates are attached to each base leg. The fins allow installation of the base without the use of concrete.
Socket mounting allows the VIS base to be removed. Oversized sleeves are secured in the ground and the base can slide in and out. This is an excellent choice for park areas with huge snowfall or flood conditions.
Wall mounted bases use a modified baseplate that facilitates installation on low walls.
Baseplate mounting allows installation where a deep footer is not practical. The base features a welded baseplate that attaches to imbeded j-bolts or all-thread rods.
Stabilizer bars are a mounting accessory for direct embedment. The bars are welded to each base leg and prevent racking due to loose and shifting soil. This is a good choice for seashore conditions.
The sled base allows the frame and post to be free standing. For security the base can be mounted with threaded rods.
Deck mount hardware uses a baseplate and anchors to install the base on wooden decks and walkways. Deck mounts are typically custom and site specific.
Direct Embedment (DE) Direct Embedment Stabalizer Fins ( SF)
Direct Embedment Socket Mount (SM)Cap Mount (CM) Baseplate Mount (BP)
Direct Embedment Stabalizer Bars (SB)Sled Base (SB) Deck Mount (DM)
Footer Overview
Scale: 1/2" = 1' 0"
Footer Overview
Scale: 1/2" = 1' 0"
Footer Overview
Scale: 1/2" = 1' 0"
Footer Overview
Scale: 1/2" = 1' 0"
Footer Overview
Scale: 1/2" = 1' 0"
Footer Overview
Scale: 1/2" = 1' 0"
3-IO - 10
GL
1-IO - 10 Low Profile Wall Cap Mount Elevationz
Scale: 1/2" = 1'-0"
3-IO - 10 Mounting Detail
Scale: 1/2 Actual Size
2-IO - 10 Baseplate Plan View
Scale: 1/2 Actual Size 3-
1/ 2"
1- 3/
4" 1-
3/ 4"
3/ 8"
7-1/4"
2" 2-1/2" 1-3/4"1"
1/2" Radius
3/8" -16 x 14" Stainless Steel
J-Bolt with Matching Nuts and Washers
Thru Hole Note: Minimum of Two Holes Per Leg
1/4"1/4"
3" eqeq eq
2"
45°
Align
B as ed o n S ig n
S iz e
2-IO -10 Mounting Hole Detail
Scale: 1/2 Actual Size
1-IO - 11 Low Profile Sled Base Side Elevation
Scale: 1/2" = 1' 0"
3-IO - 11 Top Section
Scale: 1/2" = 1' 0"
2-IO - 11
3-IO - 11
GL
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 10Revision 3 October 5, 2017
VIS graphic panels are designed to provide an attractive and consistent way to present a broad range of messages.
This includes park and facility identity, park regulations, safety warnings, information, interpretation, pedestrian guidance, low speed motorist guidance, and other wayfinding information including maps. The modular grids and design standards of VIS signs allows presentation of content in discrete, easily comprehended “eyefuls” which aids in visitor comprehension and retention of information.
Please refer to the Visitor Information System, Panel
Specification Manual for more information.
VIS Panels
Panels may be produced in porcelain enamel, high pressure laminate, fused polycarbonate, fiberglass embedment, digitally printed adhesive vinyl, or computer cut retro–reflective sheeting.
Selection of material is based on life-cycle cost, budget, exposure to wear, and need for retro–reflective legends if viewed from an auto-mobile. Production methods include digital printing, screen printing, and adhesive–backed computer–cut vinyl.
Overview
Hermit Road
Hermit Road
Lookout Studio
Kolb Studio
Maswik Lodge
Backcountry Information Center
Kennels
Hermits Rest Transfer
Village Route Transfer
Bright Angel Trailhead
Center Road
Bright Angel Lodge
Thunderbird Lodge
Bright Angel Lodge
Kachina Lodge
Parking
Trailview Overlook
Maricopa Point
Hopi Point
Mohave Point
The Abyss
Pima Point
Monument Creek Vista Hermits Rest
Hermit Trailhead
Hermits Rest Route
0.5mi / 0.8km
0.3mi / 0.5km
1.1mi. / 1 .8km
E
C
D
Parking
E
0.8mi / 1.3km
1.1mi / 1.8km
R im
T ra il
Rim Trail
Rim Trail 0.
7m i /
.1 km
Powell Point
Orphan Mine
Parking
N
S
EW
Shuttle Routes
Hermits Rest Route
Village Route
Trails
Restricted Access
Hermits Rest Route National Park Service U.S. Department of the InteriorGrand Canyon National Park
Paved Multi-Use Greenway Trail
Paved Pedestiran Greenway Trail
Unpaved Rim Trail
Hermit Trail
Paved Rim Trail
Greenway Tra il
1.7mi / 2.7 km
0.9mi. / 1.4km
0.7mi / 1.1k m
Shuttle Stop
Park Identity and Entrance Signs Park Fee Signs
Informational Signs Warning and Danger Signs
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 11Revision 3 October 5, 2017
6" and 12" Series Panel Sizes
12x6
12x24
12x36
12x48
6x6
6x12
6x18
Overview
A modular system of panels is available to fit all the
VIS hardware bases. Panel dimensions are specified by width(w) x height(h). Panels are specified in nominal dimensions. Fabricated panels are undercut by 1/16" on each side. For example, a 6" x 6" panel is 5 7/8" x 5 7/8". Post size is determined by panel or base size. Refer to the VIS
Post Hardware charts in the fabrication details.
6" Series Panels
VIS Hardware Assembly Series: TS and UP
12" Series Panels
Barstock Post
2x2 Post
VIS Hardware Assembly Series: LP and UP VIS Hardware Assembly: UP
2x3 Post
12x12
12x18
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 12Revision 3 October 5, 2017
24x12
18x24
18x36
18x48
24x18
24x24
24x36
24x48
18" and 24" Series Panel Sizes
Overview
18" Series Panels
24" Series Panels
VIS Hardware Assembly Series: LP and UP
VIS Hardware Assembly Series: LP and UP
VIS Hardware Assembly Series: UP
VIS Hardware Assembly Series: UP
Barstock Post
2x2 Post
2x3 Post
18x18
18x12
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 13Revision 3 October 5, 2017
36x12
36x24
36x18
36" Series Panel Sizes
Overview
36" Series Panels
VIS Hardware Assembly Series: LP and UP
VIS Hardware Assembly Series: UP
36x36
36x48
Barstock Post
2x2 Post
2x3 Post
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 14Revision 3 October 5, 2017
48" Series Panel Sizes
Overview
48" Series Panels
VIS Hardware Assembly Series: LP and UP
48x18
48x24
Barstock Post
2x2 Post
2x3 Post
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 15Revision 3 October 5, 2017
VIS Hardware Assembly Codes
Overview
Although the VIS is a system of simple components, material choices, panel sizes, and mounting options offer a multitude of fabrication options. In order to adequately describe a base and its attributes a code system has been created to aid in specification of base hardware.
The code system provides the information necessary to describe the base, its size, mounting, and other options for fabrication. A sample specification code might look like this:
UP_24x36_WS_DE_PF_BC The code breaks down as follows:
UP
This is the frame type. UP is the specification code for an upright base.
24x36 This is nominal frame size or bulletin case size. In this case a 24 x 36 bulletin case mounts to the base.
WS
This is the material type. This frame will be made from weathering steel.
DE
This is the mounting type. This frame will be a direct embed.
PF
This is the mounting accessory. This frame posts will have post fins for inground stabilization.
BC
This is the base accessory. In this case the base will have a bulletin case instead of a panel.
How to Specify a VIS Base
With the code system it is easy to specify the base type.
For this exercise it is assumed all the decisions about the base have been made including the size, panel content, material mounting, and location.
Use the Code Charts on the page 16 to specify your base.
Step 1. Choose Base Type
From the VIS Hardware Assembly Chart choose the correct assembly code. If necessary refer to the VIS Hardware
Assembly Descriptions on page 7.
Step 2. Choose Nominal Panel Size
If necessary refer to Panel Size Charts, beginning page 11.
Step 3. Choose Base Material
Weathering steel, galvanized steel, or painted aluminum.
Step 4. Choose Mounting Method
Step 5. Choose Mounting Accessory (If Required)
Step 6. Choose Base Accessory
This could be a bulletin case, brochure dispenser, or roof structure for a tri or quad upright.
Step 7. Additional Notes
Here you would indicate additional information for the fabricator including custom requests or modifications and colors.
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 16Revision 3 October 5, 2017
VIS Hardware Assembly Codes Charts
Overview
Trailside Base
Wall Mount
Low Profile Wayside Base
Upright Base
Upright Inline 2 (Double)
Upright Inline 3 (Triple)
Upright Tri-Sided (Kiosk)
Upright Quad-Sided (Kiosk)
Code Descriptions
VIS Hardware Assembly Type
TS
WM
LP
UP
UPN2
UPN3
UPTR
UPQU
Weathering Steel
Galvanized Steel
Painted Aluminum
Code Descriptions
VIS Material Options Chart
WS
GS
AL
Bulletin Case
Brochure Holder
Miscellanous posting
Roof Structure (Upright Only)
Strap Kit
Code Descriptions
VIS Hardware Accessory
BC
BH
MP
RS
SK
Direct Embedment
Base Plate
Socket Mount
Sled Base (Free Standing)
Deck Mount
Wall Mount
Code Descriptions
VIS Hardware Mounting Type
DE
BP
SM
SB
DM
WM
Post Fins (Embed w/o Concrete)
Stabilizer Bars (For Shifting Soils)
Code Descriptions
VIS Hardware Mounting Accessory
PF
SB
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 17Revision 3 October 5, 2017
Section I Trailside Series (TS)
Trailside Series Overview (TS) 18
Trailside Base Sizes 19
6" Series
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 18Revision 3 October 5, 2017
Trailside Series Overview (TS)
Section I: Trail Side Series
Small and simply formed, NPS “trailside” exhibits bases offer an unobtrusive way to provide brief interpretive message or important safety information with minimal impact on the landscape. Trailsides are available in weathering steel, galvanized steel, or painted aluminum and can accommodate several types of graphic panels, attached with stainless steel barrel nuts as shown on page 58. The final assembly is mounted by direct embedment into the ground. The angled tab at the bottom of the base prevents uplift and removal once the base is installed.
Trail Sign, Low Profile, Upright, Inline and Kiosks
Scale: 1/2" = 1'-0"
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 19Revision 3 October 5, 2017
Scale: 1/2" = 1'
TS-6x6
TS-6x12 TS-6x18
Section I: Trail Side Series
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 20Revision 3 October 5, 2017
Section II Wall Mount Series (WM)
Wall Mount Series Overview (WM) 21
Wall Mount Frame Sizes 22
12" Series
18" Series
24" Series
36" Series
48" Series
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 21Revision 3 October 5, 2017
Wall Mount Series Overview (WM)
Section II: Wall Mount Series
When possible and permitted, graphic panels may be mounted on walls or buildings rather than on a free-standing exhibit base by using the frame assembly illustrated here.
These frames are available in weathering steel, galvanized steel, or in painted aluminum and includes all required mounting hardware (see page 63 for mounting details). The top frame member is secured by a replaceable set screw which can be easily removed to allow panel replacement.
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 22Revision 3 October 5, 2017
12" Series
Scale: 1/2" = 1'
18" Series
Scale: 1/2" = 1'
WM-12x12 WM-12x18 WM-12x24 WM-12x36 WM-12x48 WM-18x12 WM-18x18 WM-18x24 WM-18x36
Section II: Wall Mount Series
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 23Revision 3 October 5, 2017
24" Series
Scale: 1/2" = 1'
WM-24x12 WM-24x18 WM-24x24 WM-24x36
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 24Revision 3 October 5, 2017
Scale: 1/2" = 1'
WM-36x12 WM-36x18 WM-36x24 WM-36x36 WM-36x48
GL
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 25Revision 3 October 5, 2017
Scale: 1/2" = 1'
WM-48x12 WM-48x24 WM-48x36
GL
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 26Revision 3 October 5, 2017
Section III Low Profile Series / Wayside Series (LP)
Low Profile Overview (LP) 27
Low Profile Base Sizes 28
6" Series
12" Series
18" Series
24" Series
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 27Revision 3 October 5, 2017
Low Profile Series Overview (LP)
Section III: Low Profile Series December 1, 2008
NPS “low–profile” wayside exhibit bases are designed to diminish their presence on the landscape by using the least material required to securely hold an exhibit panel. Panels are positioned at a 45–degree angle to permit visitors a clear view of the feature that the exhibit interprets. Bases are available in three materials, appropriate to a variety of landscapes: weathering steel for forested or desert environments; galvanized steel for coastal zones; and painted aluminum (in three standard colors) for urban areas. The first two materials require little maintenance.
The legs of most wayside bases are directly embedded into the ground, although other mounting methods are available to accommodate site conditions. As illustrated on the following pages, NPS waysides bases come in a wide range of panel sizes which are held within a full-frame assembly.
The top frame member is secured by a replaceable set screw which can be easily removed to allow panel replacement.
Trail Sign, Low Profile, Upright, National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 28Revision 3 October 5, 2017Section III: Low Profile Series
GL
12" Series
Scale: 1/2" = 1'
6" Series
Scale: 1/2" = 1'
LP-6x12 Barstock Post
LP-12x6 Barstock Post
LP-12x12 Barstock Post 2x2 Post
LP-12x18 2x2 Post
LP-12x24 2x3 Post
LP-6x12 Barstock Post
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 29Revision 3 October 5, 2017Section III: Low Profile Series
GL
18" Series
Scale: 1/2" = 1'
24" Series
Scale: 1/2" = 1'
LP-18x12 2x2 Post
LP-24x12 2x2 Post 2x3 Post
LP-24x18 2x3 Post
LP-24x24 2x3 Post
LP-18x18 2x2 Post 2x3 Post
LP-18x24 2x3 Post
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 30Revision 3 October 5, 2017Section III: Low Profile Series
GL
36" Series
Scale: 1/2" = 1'
48" Series
Scale: 1/2" = 1'
LP-36x12 2x3 Post
LP-48x18 2x3 Post
LP-48x24 2x3 Post
LP-36x18 2x3 Post
LP-36x24 2x3 Post
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 31Revision 3 October 5, 2017
Section IV Upright Series Architecture (UP)
Upright Series Overview (UP) 32
Upright Base Sizes 33
Upright Inline 2 Series Overview (UPN2) 37
Upright Inline 2 Base Sizes 38
Upright Inline 3 Series Overview (UPN3) 39
Upright Inline 3 Base Sizes 40
Upright Tri-Sided Series Overview (UPTR) 41
Upright Tri-Sided Base Sizes 42
Upright Roof Overview 45
Upright Roof Sizes 46
Upright Quad-Sided Series Overview (UPQU) 43
Upright Quad-Sided Base Sizes 44
6" Series
12" Series
18" Series
24" Series
36" Series
48" Series
24" Series
36" Series
24" Series
36" Series
Upright Series
Upright Inline 2 Series
Upright Inline 3 Series
Upright Tri Series
UprightQuad Series
24" Series
36" Series
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 32Revision 3 October 5, 2017
Upright Series Overview (UP)
Section IV: Upright Series
NPS “upright” bases—which are designed to stand vertically so they attract attention—typically present more general information than the interpretive messages their
“low–profile” counterparts offer. Upright bases are typically used at trailheads or boat ramps, near visitor centers, in parking areas or campgrounds, and at similar points of assembly or access. Bases are available in three materials, appropriate to a variety of landscapes: weathering steel for forested or desert environments; galvanized steel for coastal zones; and painted aluminum (in three standard colors) for urban areas. The first two materials require little maintenance. The legs of most upright bases are directly embedded into the ground, although other mounting methods are available to accommodate site conditions.
As illustrated on the following pages, NPS upright bases come in a wide range of panel sizes which are held within a full–frame assembly. The top frame member is secured by a replaceable set screw which can be easily removed to allow panel replacement.
Trail Sign, Low Profile, Upright, Inline and Kiosks
Scale: 1/2" = 1'-0"
This illustration shows a single exhibit panel. (Note:
The single panel shown here can be “double–sided” in order to have two display surfaces.)
The Upright Series hardware can also support a bulletin case or other accessories (on one or both sides) as illustrated elsewhere in this manual.
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 33Revision 3 October 5, 2017Section IV: Upright Series
Scale: 1/2" = 1'
UP-6x12 Barstock Post
UP-12x6 Barstock Post
UP-12x12 Barstock Post or 2x2 Post
UP-12x18 2x2 Post
UP-12x24 2x2 Post 2x3 Post
UP-12x36 2x3 Post
UP-12x48 2x3 Post
UP-6x18 Barstock Post
12" Series
Scale: 1/2" = 1'
GL
GL
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 34Revision 3 October 5, 2017Section IV: Upright Series
GL
24" Series
Scale: 1/2" = 1'
UP-18x12 2x2 Post
UP-18x18 2x2 Post 2x3 Post
UP-18x24 2x3 Post
UP-18x36 2x3 Post
UP-18x48 2x3 Post
UP-24x12 2x2 Post 2x3 Post
UP-24x18 2x3 Post
UP-24 x24 2x3 Post
UP-24x36 2x3 Post
UP-24x48 2x3 Post
18" Series
Scale: 1/2" = 1'
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 35Revision 3 October 5, 2017Section IV: Upright Series
Scale: 1/2" = 1'
UP-36x12 2x3 Post
UP-36x18 2x3 Post
UP-36x24 2x3 Post
UP-36x36 2x3 Post
UP-36x48 2x3 Post
GL
GL
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 36Revision 3 October 5, 2017Section IV: Upright Series
Scale: 1/2" = 1'
UP-48x12 2x3 Post
UP-48x18 2x3 Post
UP-48x24 2x3 Post
GL
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 37Revision 3 October 5, 2017Section IV: Upright Series
Upright Inline 2 Series Overview (UPN2)
When more information needs to be displayed than a single exhibit can accommodate, two upright panels can be used.
The material and color options for this configuration are the same as those available for the single panel assembly presented on page 31.
The Inline 2 Series hardware can support a bulletin case or other accessories in additionto exhibit panels. Both sides of the assembly can carry panels or accessories.
Trail Sign, Low Profile, Upright, National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 38Revision 3 October 5, 2017Section IV: Upright Series
Scale: 1/2" = 1'
36" Series
Scale: 1/2" = 1'
UPN2-24x36 2x3 Posts
UPN2-36x48 3x5 Posts
GL
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 39Revision 3 October 5, 2017Section IV: Upright Series
Upright Inline 3 Series Overview (UPN3)
When more information needs to be displayed than one or two exhibits can accommodate, three upright panels can be used. The material and color options for this configuration are the same as those available for the single panel assembly presented on page 31.
The Inline 3 Series hardware can support a bulletin case or other accessories in addition to exhibit panels. Both sides of the assembly can carry panels or accessories.
Trail Sign, Low Profile, Upright, National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 40Revision 3 October 5, 2017Section IV: Upright Series
Scale: 1/2" = 1'
UPN3-36x48 3x5 Posts
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 41Revision 3 October 5, 2017Section IV: Upright Series
Upright Tri-Side Series Overview (UPTR)
Upright structures can be configured in a tri-sided arrangement. The Tri-Sided Series can support exhibit panels, bulletin cases and other accessories. The Upright Tri Series, like all NPS hardware, is typically embedded directly into the ground, although other mounting methods are available to accommodate site conditions. The Tri-Sided Series is available in weathering or galvanized steel, or in painted aluminum.
Trail Sign, Low Profile, Upright, National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 42Revision 3 October 5, 2017Section IV: Upright Series
Scale: 1/2" = 1'
36" Series
Scale: 1/2" = 1'
UPTR-24x36 Custom Posts
UPTR-36x48 Custom Posts
GL
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 43Revision 3 October 5, 2017Section IV: Upright Series
Upright Quad-Sided Series Overview (UPQU)
Upright structures can be configured in a four-sided arrangement. The Quad-Sided Series can support exhibit panels, bulletin cases and other accessories in addition to exhibit panels. The Quad Series, like all NPS hardware, is typically embedded directly into the ground, although other mounting methods are available to accommodate site conditions. The Quad-Sided Series is available in weathering or galvanized steel, or in painted aluminum.
Trail Sign, Low Profile, Upright, National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 44Revision 3 October 5, 2017Section IV: Upright Series
Scale: 1/2" = 1'
36" Series
Scale: 1/2" = 1'
UPQU-24x36 4x4 Posts
UPQU-36x48 6x6 Posts
GL
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 45Revision 3 October 5, 2017
Upright Roof Overview
Single, inline, tri, or quad upright exhibits (in 36 x 48 panel sizes only) can include a roof structure to protect panels, bulletin cases, and other accessories, and to provide shade for park visitors. Inline assemblies are typically delivered with the roof substructure (as shown below) but without roof surface materials, which are obtained and applied by the park. However, the Tri and the Quad Series can be ordered with an aluminum roof (also see below) finished to match the other parts of the structure. (Note: all roofed structures are currently available only in painted aluminum.)
Section IV: Upright Series
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 46Revision 3 October 5, 2017Section IV: Upright Series
GL
UP-36x48 with Roof 3x5 Post
UPN3-36x48 with Roof 3x5 Post
UPN2-36x48 with Roof 3x5 Post
Scale: 1/2" = 1'
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 47Revision 3 October 5, 2017Section IV: Upright Series
GL
UPTR-36x48 with Roof Custom Post
UPQU-36x48 with Roof 6x6 Post
Scale: 1/4" = 1'
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 48Revision 3 October 5, 2017
Section V VIS Hardware Accessories
VIS Hardware Accessory Overview 49
Bulletin Case Overview 51
Bulletin Case Frame Sizes 52
Brochure Holder Overview 53
Miscellaneous Posting Overview 54
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 49Revision 3 October 5, 2017Section V: Accessories
VIS Hardware Accessory Overview
The VIS System offers a set of accessories, including a bulletin case as shown below, and holders for brochures or miscellaneous postings as illustrated on the next page.
The bulletin case can be mounted on a wall, or attached to a free–standing vertical base. For more information about the bulletin case see page 51.
Bulletin Cases can be wall mounted or attached to an Upright Base.
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 50Revision 3 October 5, 2017Section V: Accessories
VIS Hardware Accessory Overview - Continued
Upright accessories include a brochure holder and miscellaneous posting.
Accessories are attached to an upright base using an accessory mounting panel.
The accessory mounting panel is securely attached to the post legs and each accessory mounts using tamper proof hardware.
Accessory Mounting Panel
Accessories
VIS Upright Base
Accessory Frame
Accessories
VIS Upright Base
Brochure Holder (BH)
Miscellaneous Posting (MP)
Registration Box (RB)
Accessory Mounting Panel
Accessories
VIS Upright Base
Accessory Frame
Accessories
VIS Upright Base
Brochure Holder (BH)
Miscellaneous Posting (MP)
Registration Box (RB)
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 51Revision 3 October 5, 2017Section V: Accessories
Bulletin Case
GL
Visitor information that needs to be posted quickly or changed frequently is best presented in a bulletin case.
Designed to be installed on legs or attached directly to a wall, the standard NPS bulletin case features a continuous–hinge door with double locks, 3/16" clear Lexan fronts, and a back panel of powder–coated steel. Information postings are held in place by magnets. The bulletin case is constructed to provide maximum protection from the elements and is ventilated to reduce interior condensation.
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 52Revision 3 October 5, 2017
Scale: 1/2" = 1'
36" Series
Scale: 1/2" = 1'
48" Series
Scale: 1/2" = 1'
BC-24x24 BC-24x36 BC-36x24 BC-36x48 BC-48x36
GL
Section V: Accessories
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 53Revision 3 October 5, 2017
Brochure Holder
Section V: Accessories
The standard NPS brochure holder is designed to make official park folders (or trail guides) readily available while providing them with limited protection from the elements.
The holder can be used alone to carry between 25 and 40 brochures (depending on their thickness), or can be used in multiples to accommodate more. A clear Lexan cover allows the top brochure to be easily seen by visitors.
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 54Revision 3 October 5, 2017
Miscellaneous Posting
Section V: Accessories
Designed to hold an 8.5 x 11 inch sheet, the miscellaneous posting holder allows information to be printed by computer on paper or card stock and easily mounted for viewing. The
Lexan cover provides limited protection from the elements, allowing posting to be displayed for weeks or longer. Such postings could include schedules that change periodically, timely information about closures or emergencies, or other messages that need to be displayed quickly.
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 55Revision 3 October 5, 2017
Section VI VIS Fabrication Detail Drawings
Trailside (TS) 56
Wall Mount (WM) 60
Low Profile (LP) 65
Upright Series (UP) 78
Upright Inline 2 Series (UPN2) 107
Upright Inline 3 Series (UPN3) 114
Upright Tri Sided Series (UPTR) 123
Upright Quad Series (UPQU) 135
Bulletin Case with Posts (BC) 148
Bulletin Case Wall Mount (BC) 151
Brochure Holder (BH) 154
Miscellaneous Posting (MP) 156
Accessory Add-On Panel 158
Installation Options 161
Reference Charts 175
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 56Revision 3 October 5, 2017
Trailside (TS)
Section VI: Details
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 57Revision 3 October 5, 2017Section VI: Details
TS - 01
1-TS - 01 Trail Side Front and Side Elevation
Scale: 1/2" = 1' - 0"
6"
5-7/8"
3/ 4"
5/8"5/8" eq eq
Pa n el H ei g h t:
2" o r
3/ 4"
Radius 1/8"
Radius Panel Edge
Optional 1/4" Holes for 4-Corner Panel Attachment
Breakform Bend
1/4" Hole to Accept 3/8" x 1/4" Barrel Diameter 18-8
Stainless Steel Torx Pin In Head Barrel with 1/4", 10-24, 18-8 Stainless Steel, Torx Pin
In Head Machine Screw
Line of Panel
Trailside Base
2-TS - 01 Panel Attachment Detail
Scale: 1/2 Actual Size
45°
2-TS - 01
1-TS - 02
1-TS - 03
GL
Steel and Aluminum Fabrication
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 58Revision 3 October 5, 2017Section VI: Details
TS - 02
1-TS - 02 Trail Side Side Elevation
Scale: Actual Size
3/8" x 1/4" Barrel Diameter 18-8 Stainless Steel Torx Pin In Head Barrel with 1/4", 10-24, 18-8 Stainless Steel, Torx Pin
In Head Machine Screw
.250 Breakformed Steel Base
.125 Graphic Panel
6"
Panel Height: 6", 12" or 18"
1/16"
1/16"
3/4"
3/4"
2-TS - 02 Connection Detail
Scale: 1-1/2" = 1' - 0"
45°
Steel Fabrication
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 59Revision 3 October 5, 2017Section VI: Details
TS - 03
1-TS - 03 Trail Side Side Elevation
Scale: Actual Size
2-TS - 03 Connection Detail
Scale: 1-1/2" = 1"-0"
3/8" x 1/4" Barrel Diameter 18-8 Stainless Steel Torx Pin In Head Barrel with 1/4", 10-24, 18-8 Stainless Steel, Torx Pin
In Head Machine Screw
.250 Breakformed Aluminum Base
.125 Graphic Panel
6"
Panel Height: 6", 12" or 18"
1/16"
1/16"
3/4"
3/4"
45°
Aluminum Fabrication
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 60Revision 3 October 5, 2017
Wall Mount (WM)
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 61Revision 3 October 5, 2017Section VI: Details
WM - 01
GL
5/16"
3/ 4"
1/ 4"
1/ 4"
3/ 4"
4" 4"
.125" Graphic Panel
5/16"-18 x 2" Long Zinc Plated Wej-it Stud
1/4"-20x3/8" 18-8 Stainless Steel Counter Sunk Flathead, Phillips Machine Screw.
Note: Top of Frame is Connected by Screws and is Removable
1/4"-20, 18-8 Stainless Steel Machine Screw Nut Welded to Steel Angle
.125" Steel Continuous C-Channel Welded to Core Panel
Note: Channel Length Based on Sign Size
.125" Steel Core Panel Welded to Steel Angle
1" x 1" x 1/8" Breakformed Steel Angle
1-3/4" x 3/4" x 1/8" Breakformed Steel Angle
1" x 1" x 1/8" Breakformed Steel Angle
1-3/4" x 3/4" x 1/8" Breakformed Steel Angle
1-3/4"
2-WM - 01 Side Section Cut
Scale: 1/2 Actual Size
1-WM - 01 Wall Mount Elevation
Scale: 1/2" = 1'-0"
2-WM - 011-WM - 02
1/8" Drilled Weep Hole Note: See Weep Hole Chart
General Note:
All breakformed steel and aluminum frame edges shall be eased to prevent sharp edges and allow paint adherence.
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 62Revision 3 October 5, 2017Section VI: Details
WM - 02
Wall or Masonry
Slotted Mounting Hole
5/16"-18 x 2" Long Zinc Plated Wej-it Stud
1" x 1" x 1/8" Breakformed Steel Angle
1-3/4" x 2" x 1/8" Breakformed Steel Angle
.125” Steel Core Panel Welded to Steel Angle
.125 Graphic Panel
1-1/4" x 1-1/4 x 1/8" Breakformed Steel C-Channel
Welded to Core Panel
1" x 1" x 1/8" Breakformed Steel Angle
1-3/4" x 2" x 1/8" Breakformed Steel Angle
1-1/4" x 1-1/4 x 1/8" Breakformed Steel C-Channel Welded to Core Panel
3-WM - 02 Top Section Cut
Scale: 1/2 Actual Size
4" 4"
Hole Location Determined On Field Conditions
Hole Location Determined On Field Conditions
1-WM - 02 Frame Mounting Hole Locations
Scale: 1" = 1'-0"
2-WM - 02 Detail at Slotted Hole
Scale: 1/2 Actual Size
Line of Steel C-Channel
Slotted Mounting Hole
7/8"
1- 3/
4"
3-WM - 02
2-WM - 02
7/8" 7/8"
4"
3/4"
4"
3/4" See Weld Chart
Nominal Dimension + 1/2" Steel Fabrication (Continued)
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 63Revision 3 October 5, 2017Section VI: Details
WM - 03
GL
1/8" Drilled Weep Hole Note: See Weep Hole Chart
3/8"
4" 4"
.125" Graphic Panel
NPS Standard 3/16" Aluminum “F” Extrusion
5/16"-18 x 2" Long Zinc Plated Wej-it Stud
.125" Aluminum Continuous C-Channel Welded to Core Panel
Note: Channel Length Based on Sign
3/16" Aluminum Core Panel Welded to F-Extrusion
1-3/4"
1-WM - 03 Wall Mount Elevation
Scale: 1/2" = 1'-0"
2-WM - 03 Side Section Cut
Scale: 1/2 Actual Size
1/4"-20 x 5/8" Long 6061-T6 Aluminum, Counter Sunk Flat Head, Phillips Head Machine Screw.
Note: Top of Frame is Connected by Screws and is Removable
1/4"-20, 6061-T6 Aluminum Hex Nut Welded to
Aluminum Angle
2-WM - 031-WM - 04
3/ 4"
3/ 4"
1" x 1" x 3/16" Breakformed Alulminum Angle
1-3/4" x 3/4" x 3/16" Breakformed Alulminum Angle
1/ 4"
1/ 4"
General Note:
All breakformed steel and aluminum frame edges shall be eased to prevent sharp edges and allow paint adherence.
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 64Revision 3 October 5, 2017Section VI: Details
WM - 04
7/8" 7/8"
4" 4"
Hole Location Determined On Field Conditions Hole Location Determined On Field Conditions
Hole Location Determined On Field Conditions
Slotted Mounting Hole
Line of Aluminum C-Channel
Slotted Mounting Hole
7/8"
1- 3/
4"
3-WM - 04 Top Section Cut
Scale: 1/2 Actual Size
1-WM - 04 Frame Mounting Hole Locations
Scale: 1" = 1'-0"
2-WM - 04 Detail at Slotted Hole
Scale: 1/2 Actual Size
3-WM - 04
2-WM - 04
Wall or Masonry
5/16"-18 x 2" Long Zinc Plated Wej-it Stud
NPS Standard 3/16" Aluminum “F” Extrusion
.125" Steel Core Panel Welded to Steel Angle
.125 Graphic Panel
1-1/4" x 1-1/4 x 1/8" Breakformed Steel C-Channel
Welded to Core Panel
See Weld Chart
Standard NPS 3/16" Breakformed Aluminum “F” Extrusion
1-1/4" x 1-1/4 x 1/8" Breakformed Steel C-Channel Welded to Core Panel
4"
3/4"
4"
3/4"
Nominal Dimension + 1/2"
Aluminum Fabrication (Continued)
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 65Revision 3 October 5, 2017
Low Profile (LP)
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 66Revision 3 October 5, 2017
Low Profile (LP): Barstock Post
Steel Fabrication
Section VI: Details
LP - 01
General Note:
All breakformed steel and aluminum frame edges shall be eased to prevent sharp edges and allow paint adherence.
.125" Steel Core Panel Welded to Angle
.090 to .125 Graphic Panel
3/8" x 1/4" Barrel Diameter 18-8 Stainless Steel, Torx Pin In Head
Barrel with 1/4", 10-24, 18-8 Stainless Steel, Torx Pin In Head Machine Screw
1" x 1" Continuous .125" Breakformed Steel Angle
1-3/4" x 3/4"x 1/8" Breakformed Steel Angle
1/8" Drilled Weep Hole Note: See Weep Hole Chart
1/2" x 2" Steel Barstock Post
5/1 6"
3/4"
3/4"
1- 3/4
1-LP - 01 Low Profile Elevation
Scale: 1/2" = 1' -0"
1/4"-20 x 3/8" Long 18-8 Stainless Steel, Flat Head, Phillips Machine Screw Note: Top of Frame is Connected by Screws and is Removable
Note: Ease Top Edge of Post
1/4"-20, 316 Stainless Steel Machine Screw Nut
Welded to Steel Angle
2"
Note: Grind Flush
67.5°
67.5°
45°
2-LP - 01 Post Detail
Scale: 3" = 1'-0"
3-LP - 01 Side Section Cut
Scale: 1/2 Actual Size
See Installation Options
2"1/2"
3-LP - 01 2-LP - 01
1-
LP
GL
1" x 1" x 1/8" Breakformed Steel Angle
1-3/4" x 3/4"x 1/8" Breakformed Steel Angle
45°
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 67Revision 3 October 5, 2017Section VI: Details
LP - 02
1/8" Steel Core Panel Welded to Steel Angle
.090 to .125 Graphic Panel
1/16" Gap For Panel Expansion
1" x 1" x 1/8" Breakformed Steel Angle
2" x 3/4" x 1/8" Breakformed Steel Angle
1" x 1" x 1/8" Breakformed Steel Angle
3/8" x 1/4" Barrel Diameter 18-8 Stainless Steel Torx Pin In Head Barrel with 1/4", 10-24, 18-8 Stainless Steel, Torx Pin In Head Machine Screw
1/16" Gap for Panel Expansion
2" x 3/4" x 1/8" Breakformed Steel Angle
1/2" x 2" Steel Barstock Posts
Line Of 1/8" Steel Frame
Line Of 1/8" Undercut Graphic Panel
1/2" x 2" Steel Barstock Posts
1-LP - 02 Frame Front Elevation
Scale: 1/2 Actual Size
2-LP - 02 Frame Top Section Cut
Scale: 1/2 Actual Size
1/8" Undercut Panel
1/ 8"
U n d er cu t
Pa n el
5/
3/ 4"
1/
3/4"
1/16"
1- 3/
4"
2-LP - 02
See Weld Chart
N o m in al D im en si o n
/2
National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 68Revision 3 October 5, 2017
2"1/2"
3/16" Aluminum Core Panel Welded to “F”…