This is an architectural drawing set for the New Hampshire Army National Guard (NHARNG) Lebanon Readiness Center door replacement project located at 174 Heater Road, Lebanon, NH 03766. The project, managed by Turner Group with offices in Concord, NH, involves exterior door upgrades to the facility's primary entrance, secondary entrances, delivery entrance, exit-only door, and boiler room door. The scope of work includes demolition of existing door frames and hardware, installation of new hollow metal and bullet-resistant hollow metal doors with frames, coordination with existing access control systems including proximity readers and intercom devices, electrical modifications to support door latch retraction devices and position sensors, and restoration of existing masonry openings. The drawing set comprises five sheets: a cover sheet, demolition floor plan (D1.1), floor plan (A1.1), exterior elevations (A1.2), and door schedule and details (A2.1), with construction documents issued for bidding on June 10, 2026.

The project specifies five door replacements (E101, E102, E103, E104, and E105) with varying configurations, including paired doors at 5'-4" and 8'-4" widths at 7'-0" height, and includes provisions for glazing with one-way vision in certain locations as designated in the specification sections. All hollow metal frames must coordinate with existing masonry opening dimensions, with frames anchored using wall-type expansion anchors. The contractor is responsible for protecting existing building structure and finishes, maintaining weather-tight conditions during demolition, removing and reinstalling existing card reader systems and electrical components, and complying with all federal, state, and local codes and ordinances. The drawings indicate that existing electrical systems, proximity readers, and intercom devices are to remain and be interconnected to the new electrical door latch retraction devices, with specific hardware sets and glazing types referenced in project specification sections 08 71 00 and 08 88 53.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N

LOCUS MAP

ARCHITECTURAL:

ELECTRICAL ENGINEERING:

PROJECT TEAM:

TURNER GROUP

27 LOCKE RD. CONCORD, NH 03301

603.228.1122

TTG PROJECT NUMBER:

DRAWING INDEX:

EXTERIOR DOOR UPGRADES

174 HEATER ROAD LEBANON, NH 03766

ISSUED FOR CONSTRUCTION

06/10/2026

1 MINUTEMAN WAY CONCORD NH 03301

DEPARTMENT OF MILITARY AFFAIRS AND

VETERANS SERVICES

LEBANON READINESS CENTER

PROJECT SITE

DRAWING LIST

SHEET

NUMBER DRAWING TITLE

COVER COVER SHEET

D1.1 DEMOLITION FLOOR PLAN

A1.1 FLOOR PLAN

A1.2 EXTERIOR ELEVATIONS

A2.1 DOOR SCHEDULE & DETAILS

RESTRM.

RESTRM.

JANITOR

SUPPLY

ROOM

TRAINING

CORRIDOR

LOCKERS

GYM

KITCHEN

BOILER

RECRUITER

OFFICE

ADMIN.

OFFICE

VAULT

DRILL HALL

NOTE: EXISTING AIPHONES & PROXIMITY READERS TO REMAIN.

GENERAL DEMOLITION NOTES

X

LEGEND

- DESIGNATION FOR ITEMS TO BE

REMOVED

- CONSTRUCTION NOTE. SEE

LEGEND BELOW

DEMOLITION NOTE LEGEND

- DESIGNATION FOR EXISTING ITEMS

TO BE REPLACED

- DESIGNATION FOR EXISTING ITEMS

TO REMAIN

1 REMOVE DOOR, FRAME & HARDWARE IN THEIR ENTIRETY; PRESERVE

EXIST. MASONRY WORK, AS APPLICABLE; PREPARE OPENING FOR

DOOR, FRAME & HARDWARE, AS SCHEDULED.

1. PROVIDE TEMPORARY BARRICADES AND PROTECTION TO PREVENT INJURY TO

PEOPLE AND DAMAGE TO ADJACENT CONSTRUCTION TO REMAIN.

2. DURING DEMOLITION ACTIVITIES, MAINTAIN BUILDING SO IT REMAINS WATER TIGHT

AND WEATHER TIGHT.

3. UNLESS DEMOLISHED MATERIAL IS INDICATED TO REMAIN OR TO BE TURNED OVER

TO THE OWNER, REMOVE MATERIAL FROM PROJECT SITE AND DISPOSE OF

LEGALLY.

4. THE CONTRACTOR IS TO PROTECT THE EXISTING BUILDING STRUCTURE AND

FINISHES TO REMAIN.

5. WHEN UTILITY SYSTEMS NEED TO BE REMOVED, PROVIDE CAP, VALVE, PLUG, OR

SEAL TO MEET CODE REQUIREMENTS AND MAINTAIN CONTINUUM OF THE SYSTEM.

6. THE CONTRACTOR IS TO CAP AND PROTECT ALL UTILITES AS ENCOUNTERED.

7. ALL DIMENSIONS INDICATED ARE PLUS OR MINUS UNLESS OTHERWISE NOTED.

8. DEMOLITION FOR THIS PROJECT IS INDICATED, BUT NOT LIMITED, BY THAT SHOWN

ON THESE DRAWINGS, AND ANY ADDITIONAL DEMOLITION REQUIRED TO

SUCCESSFULLY COMPLETE CONSTRUCTION IS A REQUIREMENT OF THIS CONTRACT.

9. ANY EXISTING COMPONENTS, THAT INTERFERE WITH PROPOSED WORK, SHALL BE

REMOVED AND REINSTALLED AS REQUIRED.

10. DEMOLITION AND CONSTRUCTION AREAS SHALL BE BARRICADED AS NECESSARY TO

COMPLY WITH ALL LOCAL, STATE AND FEDERAL CODES AND ORDINANCES. DUST

CONTROL SYSTEMS SHALL BE INSTALLED AND REMAIN IN PLACE AS NECESSARY TO

CONTROL DUST ON THIS PROJECT UNLESS OTHERWISE NOTED.

11. PROVIDE ALL LIFTS, SHORING, BRACING, ETC., AS REQUIRED TO STABILIZE AND

PROTECT EXISTING AND ADJACENT STRUCTURES DURING CONSTRUCTION.

12. COMPLY WITH ALL FEDERAL, STATE AND LOCAL GUIDELINES AND REQUIREMENTS AT

ALL TIMES DURING THE IMPLEMENTATION OF THE WORK.

13. CONTRACTOR IS TO REMOVE & REINSTALL EXISTING CARD READER SYSTEM, WHERE

APPLICABLE.

SHEET TITLE:

SEAL:

REVISIONS:

PROJ. NO.:

SCALE:

DESN. BY:

DRAWN BY:

CHKD BY:

ISSUE DATE:

ISSUE:

KEY PLAN:

SHEET INFORMATION:

PROJECT TEAM:

PROJECT INFORMATION:

As indicated

H E

A T

E R

R O

A D

L E

B A

N O

N

N H

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A F

F A

IR

S

A N

D V

E T

E R

A N

S

S E

R V

IC

E

S

XX/XX/XXXX

DEMOLITION FLOOR PLAN

D1.1

JWS

AZ

AZ

ISSUED FOR CONSTRUCTION

06/10/2026

E X

T E

R

IO

R D

O O

R U

P G

R A

D E

S

M

IN

U

T E

M A

N W

A Y

C O

N C

O R

D N

H

L E

B A

N O

N R

E A

D

IN

E S

S C

E N

T E

R

Scale:D1.1 1/8" = 1'-0"

1 DEMOLITION FLOOR PLAN

ROOF SCUTTLE

BATHROOM

BATH

JANITOR

SUPPLY

ROOM

TRAINING

CORRIDOR

LOCKERS

GYM

KITCHEN

BOILER

RECRUITER

OFFICE

ADMIN.

OFFICE

VAULT

DRILL HALL

E101

E104

E102

E103

E105

EXIT ONLY DOOR

SECONDARY ENTRANCE DOOR

SECONDARY ENTRANCE DOOR (DELIVERIES)

PRIMARY ENTRANCE DOOR

BOILER ROOM DOOR

X

LEGEND

- DESIGNATION FOR ITEMS TO BE

REMOVED

- CONSTRUCTION NOTE. SEE

LEGEND BELOW

CONSTRUCTION NOTE LEGEND

- DESIGNATION FOR EXISTING ITEMS

TO BE REPLACED

- DESIGNATION FOR EXISTING ITEMS

TO REMAIN

1. DO NOT SCALE DRAWINGS.

2. VERIFY ALL DIMENSIONS AND CONDITIONS OF EXISTING BUILDING ELEMENTS IN THE

FIELD PRIOR TO COMMENCING WORK; NOTIFY ARCHITECT OF ANY DISCREPANCIES

DISCOVERED BEFORE PROCEEDING WITH ANY WORK.

3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE CAUSED BY THEIR

OPERATIONS WHILE ON SITE. ANY AND ALL DAMAGE SHALL BE REPAIRED TO THE

SATISFACTION OF THE OWNER AND ARCHITECT/ENGINEER.

4. THE CONTRACTOR SHALL PROVIDE BLOCKING FOR ALL GENERAL CONSTRUCTION

WORK AND ELECTRICAL DEVICES AS REQUIRED.

5. ALL LUMBER IN DIRECT CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED.

6. THE CONTRACTOR SHALL REVIEW, PRIOR TO INSTALLATION, ANY CONFLICT OF

ENGINEERING TRADE DEVICES WITH ARCHITECTURAL DETAILS AND BRING THOSE

DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT FOR REVIEW.

7. ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE, FACE OF MASONRY

OR CENTER OF OPENING, UNLESS OTHERWISE NOTED.

8. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATION NOT CONTAINED IN

THESE DRAWINGS.

GENERAL FLOOR PLAN NOTES

HOLLOW METAL DOOR, FRAME & HARDWARE, AS

SCHEDULED, IN EXISTING MASONRY OPENING.

2 NOT USED

BULLET RESISTANCE HOLLOW METAL DOOR, FRAME &

HARDWARE, AS SCHEDULED, IN EXISTING MASONRY

OPENING.

EXISTING ACCESS CONTROL POXIMITY READER TO REMAIN

INTERCONNECT TO ELECTRICAL DOOR LATCH RETRACTION

DEVICE

EXISTING AIPHONE TO REMAIN. INTERCONNECT TO

ELECTRICAL DOOR LATCH RETRACTION DEVICE

SHEET TITLE:

SEAL:

REVISIONS:

PROJ. NO.:

SCALE:

DESN. BY:

DRAWN BY:

CHKD BY:

ISSUE DATE:

ISSUE:

KEY PLAN:

SHEET INFORMATION:

PROJECT TEAM:

PROJECT INFORMATION:

As indicated

H E

A T

E R

R O

A D

L E

B A

N O

N

N H

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A F

F A

IR

S

A N

D V

E T

E R

A N

S

S E

R V

IC

E

S

XX/XX/XXXX

FLOOR PLAN

A1.1

JWS

AZ

AZ

ISSUED FOR CONSTRUCTION

06/10/2026

E X

T E

R

IO

R D

O O

R U

P G

R A

D E

S

M

IN

U

T E

M A

N W

A Y

C O

N C

O R

D N

H

L E

B A

N O

N R

E A

D

IN

E S

S C

E N

T E

R

N

Scale:A1.1 1/8" = 1'-0"

1 FLOOR PLAN

14 E105 E1042 2 3

1E101 2 3

GENERAL DEMOLITION NOTES

X

LEGEND

- DESIGNATION FOR ITEMS TO BE

REMOVED

- CONSTRUCTION NOTE. SEE

LEGEND BELOW

ELEVATION CONSTRUCTION NOTE LEGEND

- DESIGNATION FOR EXISTING ITEMS

TO BE REPLACED

- DESIGNATION FOR EXISTING ITEMS

TO REMAIN

GENERAL ELEVATION NOTES

BULLET RESISTANT HOLLOW METAL DOOR, FRAME &

HARDWARE, AS SCHEDULED, IN EXISTING MASONRY

OPENING.

EXISTING PROXIMITY READER, INTERCONNECT TO

ELECTRICAL DOOR LATCH RETRACTION DEVICE.

1. PROVIDE TEMPORARY BARRICADES AND PROTECTION TO PREVENT INJURY TO

PEOPLE AND DAMAGE TO ADJACENT CONSTRUCTION TO REMAIN.

2. DURING DEMOLITION ACTIVITIES, MAINTAIN BUILDING SO IT REMAINS WATER TIGHT

AND WEATHER TIGHT.

3. UNLESS DEMOLISHED MATERIAL IS INDICATED TO REMAIN OR TO BE TURNED OVER

TO THE OWNER, REMOVE MATERIAL FROM PROJECT SITE AND DISPOSE OF

LEGALLY.

4. THE CONTRACTOR IS TO PROTECT THE EXISTING BUILDING STRUCTURE AND

FINISHES TO REMAIN.

5. WHEN UTILITY SYSTEMS NEED TO BE REMOVED, PROVIDE CAP, VALVE, PLUG, OR

SEAL TO MEET CODE REQUIREMENTS AND MAINTAIN CONTINUUM OF THE SYSTEM.

6. THE CONTRACTOR IS TO CAP AND PROTECT ALL UTILITES AS ENCOUNTERED.

7. ALL DIMENSIONS INDICATED ARE PLUS OR MINUS UNLESS OTHERWISE NOTED.

8. DEMOLITION FOR THIS PROJECT IS INDICATED, BUT NOT LIMITED, BY THAT SHOWN

ON THESE DRAWINGS, AND ANY ADDITIONAL DEMOLITION REQUIRED TO

SUCCESSFULLY COMPLETE CONSTRUCTION IS A REQUIREMENT OF THIS CONTRACT.

9. ANY EXISTING COMPONENTS, THAT INTERFERE WITH PROPOSED WORK, SHALL BE

REMOVED AND REINSTALLED AS REQUIRED.

10. DEMOLITION AND CONSTRUCTION AREAS SHALL BE BARRICADED AS NECESSARY TO

COMPLY WITH ALL LOCAL, STATE AND FEDERAL CODES AND ORDINANCES. DUST

CONTROL SYSTEMS SHALL BE INSTALLED AND REMAIN IN PLACE AS NECESSARY TO

CONTROL DUST ON THIS PROJECT UNLESS OTHERWISE NOTED.

11. PROVIDE ALL LIFTS, SHORING, BRACING, ETC., AS REQUIRED TO STABILIZE AND

PROTECT EXISTING AND ADJACENT STRUCTURES DURING CONSTRUCTION.

12. COMPLY WITH ALL FEDERAL, STATE AND LOCAL GUIDELINES AND REQUIREMENTS AT

ALL TIMES DURING THE IMPLEMENTATION OF THE WORK.

13. CONTRACTOR IS TO REMOVE & REINSTALL EXISTING CARD READER SYSTEM, WHERE

APPLICABLE.

EXISTING INTERCOM DEVICE, INTERCONNECT TO

ELECTRICAL DOOR LATCH RETRACTION DEVICE

HOLLOW METAL DOOR, FRAME & HARDWARE, AS

SCHEDULED, IN EXISTING MASONRY OPENING.

1E102

1E103 2

SHEET TITLE:

SEAL:

REVISIONS:

PROJ. NO.:

SCALE:

DESN. BY:

DRAWN BY:

CHKD BY:

ISSUE DATE:

ISSUE:

KEY PLAN:

SHEET INFORMATION:

PROJECT TEAM:

PROJECT INFORMATION:

As indicated

H E

A T

E R

R O

A D

L E

B A

N O

N

N H

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A F

F A

IR

S

A N

D V

E T

E R

A N

S

S E

R V

IC

E

S

XX/XX/XXXX

EXTERIOR ELEVATIONS

A1.2

JWS

AZ

AZ

ISSUED FOR CONSTRUCTION

06/10/2026

E X

T E

R

IO

R D

O O

R U

P G

R A

D E

S

M

IN

U

T E

M A

N W

A Y

C O

N C

O R

D N

H

L E

B A

N O

N R

E A

D

IN

E S

S C

E N

T E

R

Scale:A1.2 1/8" = 1'-0"

4 EAST ELEVATION

Scale:A1.2 1/8" = 1'-0"

2 SOUTH ELEVATION

Scale:A1.2 1/8" = 1'-0"

3 WEST ELEVATION

Scale:A1.2 1/8" = 1'-0"

1 NORTH ELEVATION

DOOR SCHEDULE NOTES

DOOR SCHEDULE LEGEND

1. PROVIDE GLAZING PER GLAZING SCHEDULE w/ ONE-WAY VISION.

2. COORDINATE ALL HOLLOW METAL FRAME THROAT DIMENSIONS

WITH EXISTING MASONRY OPENINGS.

3. G: 3' - 0" ACTIVE LEAF, F: 2' - 4" INACTIVE LEAF

4. INSULATED DOOR

5. NO LEVER TRIM ON EXTERIOR OF DOOR

6. NOTE, ACTIVE LEAF ON LEFT FROM EXTERIOR TO PROVIDE ADA

CLEARANCE TO EXISTING PROXIMITY READER LOCATION.

7. DOOR HAS EXISTING PROXIMITY READER TO REMAIN.

8. DOOR HASA EXISTING INTERCOM WITH REMOTE DOOR RELEASE

TO REMAIN

H.M. - HOLLOW METAL

PT - PAINTED; COLOR AS SELECTED BY OWNER

HARDWARE SETS

SEE SPECIFICATION SECTION 08 71 00 FOR HARDWARE SETS.

GLAZING TYPES

SEE SPECIFICATION SECTION 08 88 53 FOR

GLAZING SCHEDULE

TYPE F TYPE G

WIDTH

H E

IG

H

T

WIDTH

H E

IG

H

T

7"

M A

X T

O V

IS

IB

LE

L

IT

E

F O

R A

D A

3'

7" 2" 2"

WIDTH

H E

IG

H

T

A2

EXIST. EXT. MASONRY WALL

& LINTELS TO REMAIN, TYPICAL U.O.N.

D O

O R

H E

IG

H

T

EXIST. METAL DOOR FRAME

TO BE REMOVED, SHOWN DOTTED

BACKER ROD & SEALANT,

TYP. EACH SIDE

A S

S C

H E

D U

L E

D

INSUL. H.M. DOOR,

AS SCHED.

5 3/4"

2"

H.M. FRAME, AS SCHED.

3"

PAINT EXIST. LINTELS

2" 1/

4"

EXIST. EXT. MASONRY WALL

TO REMAIN, TYPICAL U.O.N.

H.M. FRAME

w/EXIST. WALL-TYPE EXPANSION ANCHOR, MIN. (3) REQ'D. PER JAMB

DOOR WIDTH

EXIST. CONC. FILLED METAL DOOR FRAME

& JAMB ANCHORS TO BE REMOVED,

SHOWN DOTTED.

V .I.

F

1'

AS SCHEDULED

INSUL. H.M. DOOR,

AS SCHED.

NOTE: PORTION OF EXIST.

JAMB ANCHORS TO REMAIN

BACKER ROD & SEALANT,

TYP. EACH SIDE

5/8" 2" 3/8"

3"

3/ 4"

2"

EXIST. CONCRETE FLOOR SLAB

TO REMAIN UNDISTURBED, TYP. U.O.N.

H.M. FRAME BEYOND

INSUL. H.M. DOOR,

AS SCHED.

EXIST. EXT. MASONRY WALL BEYOND

TO REMAIN, TYPICAL U.O.N.

ALUMINUM THRESHOLD,

SET IN MASTIC

EXIST. THRESHOLD

w/SLAB ANCHOR & WEATHERSTRIPPING

TO BE REMOVED (SHOWN DOTTED)

CONDUIT & CONDUCTORS,

REPLACE FROM EXIT

DEVICE TO JUNCTION BOX

EXISTING CONDUIT TO REMAIN, REVISE

CONDUCTORS AS REQUIRED

EXIT DEVICE WITH ELR

DOOR LOOP ELEC. PASS THRU

DOOR POSITION SENSOR,

SURFACE MOUNTED

EXISTING REQUEST TO EXIT

DEVICE AND JUNCTION BOX

EXISTING JUNCTION BOX

WITH POWER TO REMAIN

CONDUIT & CONDUCTORS TO

DOOR POSITION INDICATORS

EXISTING CONDUIT AND

CONDUCTOR TO ACCESS

CONTROL SYSTEM TO

REMAIN

EXISTING BOX FOR

AIPHONE AND PROX

READER TO REMAIN

EXISTING CONDUIT TO REMAIN,

REVISED CONDUCTORS AS

REQUIRED

SHEET TITLE:

SEAL:

REVISIONS:

PROJ. NO.:

SCALE:

DESN. BY:

DRAWN BY:

CHKD BY:

ISSUE DATE:

ISSUE:

KEY PLAN:

SHEET INFORMATION:

PROJECT TEAM:

PROJECT INFORMATION:

As indicated

H E

A T

E R

R O

A D

L E

B A

N O

N

N H

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

A F

F A

IR

S

A N

D V

E T

E R

A N

S

S E

R V

IC

E

S

XX/XX/XXXX

DOOR SCHEDULE & DETAILS

A2.1

JWS

AZ

AZ

ISSUED FOR CONSTRUCTION

06/10/2026

E X

T E

R

IO

R D

O O

R U

P G

R A

D E

S

M

IN

U

T E

M A

N W

A Y

C O

N C

O R

D N

H

L E

B A

N O

N R

E A

D

IN

E S

S C

E N

T E

R

Scale:A2.1 1/4" = 1'-0"

4 DOOR TYPES

Scale:A2.1 1/4" = 1'-0"

5 FRAME TYPES

DOOR AND FRAME SCHEDULE

DOOR #

ROOM

NAME

DOOR FRAME DETAIL LOCATION

FUNCTION

HARDWARE

SET DOOR NOTES

DOOR

TYPE WIDTH HEIGHT THICKNESS

GLAZING

TYPE MAT. FIN.

FRAME

TYPE MAT. FIN. HEAD JAMB SILL

E101

E102

E105

ASSEMBLY HALL

ASSEMBLY HALL

BOILER ROOM

G/F(PAIR) 5' - 4" 7' - 0" 1 3/4"

1 3/4"

1 3/4"

IG-1

B.R.H.M. PT-3/PT-4

PT-3/PT-4

PT-3/PT-4

A2

A2

A2

B.R.H.M. PT-3/PT-4

PT-3/PT-4

PT-3/PT-4

1/E2.1 2/E2.1 3/E2.1 ENTRY / EXIT

ENTRY / EXIT

Scale:A2.1 3" = 1'-0"

1 HEAD DETAIL - H.M. DOOR REPLACEMENT

Scale:A2.1 3" = 1'-0"

2 JAMB DETAIL - H.M. DOOR REPLACEMENT

Scale:A2.1 3" = 1'-0"

3 THRESHOLD DETAIL - H.M. DOOR REPLACEMENT

E104

E103

ASSEMBLY HALL

CORRIDOR

G/F(PAIR)

8' - 4"6' - 0"

1 3/4"

1 3/4"

PT-3/PT-4

PT-3

A2

A2 H.M.

PT-3/PT-4

PT-3 ENTRY / EXIT

ENTRY / EXIT

EXIT ONLY

5' - 4" 7' - 0"

5' - 4" 7' - 0"

5' - 4" 7' - 0"

G/F(PAIR)

F/F(PAIR)

F/F(PAIR)

1, 2, 3, 4, 6

IG-1

IG-1 1/E2.1 2/E2.1 3/E2.1

1/E2.1 2/E2.1 3/E2.1

1/E2.1 2/E2.1 3/E2.1

1/E2.1 2/E2.1 3/E2.1

1, 2, 3, 4

1, 2, 3, 4

2, 3, 4, 5

2, 4

B.R.H.M.

B.R.H.M.

B.R.H.M.

H.M.

B.R.H.M.

B.R.H.M.

B.R.H.M.

COORDINATE

HEAD HEIGHT OF

FRAME WITH

EXISTING M.O.

Scale:A2.1 3/8" = 1'-0"

6 DOOR E104 DIAGRAM

Scale:A2.1 1" = 1'-0"

7 DOOR E104 PHOTO

Sheets
A1.1 - FLOOR PLAN
A1.2 - EXTERIOR ELEVATIONS
A2.1 - DOOR SCHEDULE & DETAILS
COVER - COVER SHEET
D1.1 - DEMOLITION FLOOR PLAN