attachment-7---drawings.pdf
PDF 18 MB Posted
- Solicitation number
- RFB-DMAVS-2027-02
- Issued by
- New Hampshire
About this file
This is an architectural drawing set for the New Hampshire Army National Guard (NHARNG) Lebanon Readiness Center door replacement project located at 174 Heater Road, Lebanon, NH 03766. The project, managed by Turner Group with offices in Concord, NH, involves exterior door upgrades to the facility's primary entrance, secondary entrances, delivery entrance, exit-only door, and boiler room door. The scope of work includes demolition of existing door frames and hardware, installation of new hollow metal and bullet-resistant hollow metal doors with frames, coordination with existing access control systems including proximity readers and intercom devices, electrical modifications to support door latch retraction devices and position sensors, and restoration of existing masonry openings. The drawing set comprises five sheets: a cover sheet, demolition floor plan (D1.1), floor plan (A1.1), exterior elevations (A1.2), and door schedule and details (A2.1), with construction documents issued for bidding on June 10, 2026.
The project specifies five door replacements (E101, E102, E103, E104, and E105) with varying configurations, including paired doors at 5'-4" and 8'-4" widths at 7'-0" height, and includes provisions for glazing with one-way vision in certain locations as designated in the specification sections. All hollow metal frames must coordinate with existing masonry opening dimensions, with frames anchored using wall-type expansion anchors. The contractor is responsible for protecting existing building structure and finishes, maintaining weather-tight conditions during demolition, removing and reinstalling existing card reader systems and electrical components, and complying with all federal, state, and local codes and ordinances. The drawings indicate that existing electrical systems, proximity readers, and intercom devices are to remain and be interconnected to the new electrical door latch retraction devices, with specific hardware sets and glazing types referenced in project specification sections 08 71 00 and 08 88 53.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N
LOCUS MAP
ARCHITECTURAL:
ELECTRICAL ENGINEERING:
PROJECT TEAM:
TURNER GROUP
27 LOCKE RD. CONCORD, NH 03301
603.228.1122
TTG PROJECT NUMBER:
DRAWING INDEX:
EXTERIOR DOOR UPGRADES
174 HEATER ROAD LEBANON, NH 03766
ISSUED FOR CONSTRUCTION
06/10/2026
1 MINUTEMAN WAY CONCORD NH 03301
DEPARTMENT OF MILITARY AFFAIRS AND
VETERANS SERVICES
LEBANON READINESS CENTER
PROJECT SITE
DRAWING LIST
SHEET
NUMBER DRAWING TITLE
COVER COVER SHEET
D1.1 DEMOLITION FLOOR PLAN
A1.1 FLOOR PLAN
A1.2 EXTERIOR ELEVATIONS
A2.1 DOOR SCHEDULE & DETAILS
RESTRM.
RESTRM.
JANITOR
SUPPLY
ROOM
TRAINING
CORRIDOR
LOCKERS
GYM
KITCHEN
BOILER
RECRUITER
OFFICE
ADMIN.
OFFICE
VAULT
DRILL HALL
NOTE: EXISTING AIPHONES & PROXIMITY READERS TO REMAIN.
GENERAL DEMOLITION NOTES
X
LEGEND
- DESIGNATION FOR ITEMS TO BE
REMOVED
- CONSTRUCTION NOTE. SEE
LEGEND BELOW
DEMOLITION NOTE LEGEND
- DESIGNATION FOR EXISTING ITEMS
TO BE REPLACED
- DESIGNATION FOR EXISTING ITEMS
TO REMAIN
1 REMOVE DOOR, FRAME & HARDWARE IN THEIR ENTIRETY; PRESERVE
EXIST. MASONRY WORK, AS APPLICABLE; PREPARE OPENING FOR
DOOR, FRAME & HARDWARE, AS SCHEDULED.
1. PROVIDE TEMPORARY BARRICADES AND PROTECTION TO PREVENT INJURY TO
PEOPLE AND DAMAGE TO ADJACENT CONSTRUCTION TO REMAIN.
2. DURING DEMOLITION ACTIVITIES, MAINTAIN BUILDING SO IT REMAINS WATER TIGHT
AND WEATHER TIGHT.
3. UNLESS DEMOLISHED MATERIAL IS INDICATED TO REMAIN OR TO BE TURNED OVER
TO THE OWNER, REMOVE MATERIAL FROM PROJECT SITE AND DISPOSE OF
LEGALLY.
4. THE CONTRACTOR IS TO PROTECT THE EXISTING BUILDING STRUCTURE AND
FINISHES TO REMAIN.
5. WHEN UTILITY SYSTEMS NEED TO BE REMOVED, PROVIDE CAP, VALVE, PLUG, OR
SEAL TO MEET CODE REQUIREMENTS AND MAINTAIN CONTINUUM OF THE SYSTEM.
6. THE CONTRACTOR IS TO CAP AND PROTECT ALL UTILITES AS ENCOUNTERED.
7. ALL DIMENSIONS INDICATED ARE PLUS OR MINUS UNLESS OTHERWISE NOTED.
8. DEMOLITION FOR THIS PROJECT IS INDICATED, BUT NOT LIMITED, BY THAT SHOWN
ON THESE DRAWINGS, AND ANY ADDITIONAL DEMOLITION REQUIRED TO
SUCCESSFULLY COMPLETE CONSTRUCTION IS A REQUIREMENT OF THIS CONTRACT.
9. ANY EXISTING COMPONENTS, THAT INTERFERE WITH PROPOSED WORK, SHALL BE
REMOVED AND REINSTALLED AS REQUIRED.
10. DEMOLITION AND CONSTRUCTION AREAS SHALL BE BARRICADED AS NECESSARY TO
COMPLY WITH ALL LOCAL, STATE AND FEDERAL CODES AND ORDINANCES. DUST
CONTROL SYSTEMS SHALL BE INSTALLED AND REMAIN IN PLACE AS NECESSARY TO
CONTROL DUST ON THIS PROJECT UNLESS OTHERWISE NOTED.
11. PROVIDE ALL LIFTS, SHORING, BRACING, ETC., AS REQUIRED TO STABILIZE AND
PROTECT EXISTING AND ADJACENT STRUCTURES DURING CONSTRUCTION.
12. COMPLY WITH ALL FEDERAL, STATE AND LOCAL GUIDELINES AND REQUIREMENTS AT
ALL TIMES DURING THE IMPLEMENTATION OF THE WORK.
13. CONTRACTOR IS TO REMOVE & REINSTALL EXISTING CARD READER SYSTEM, WHERE
APPLICABLE.
SHEET TITLE:
SEAL:
REVISIONS:
PROJ. NO.:
SCALE:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
ISSUE:
KEY PLAN:
SHEET INFORMATION:
PROJECT TEAM:
PROJECT INFORMATION:
As indicated
H E
A T
E R
R O
A D
L E
B A
N O
N
N H
D E
P A
R T
M E
N T
O F
M
IL
IT
A
R Y
A F
F A
IR
S
A N
D V
E T
E R
A N
S
S E
R V
IC
E
S
XX/XX/XXXX
DEMOLITION FLOOR PLAN
D1.1
JWS
AZ
AZ
ISSUED FOR CONSTRUCTION
06/10/2026
E X
T E
R
IO
R D
O O
R U
P G
R A
D E
S
M
IN
U
T E
M A
N W
A Y
C O
N C
O R
D N
H
L E
B A
N O
N R
E A
D
IN
E S
S C
E N
T E
R
Scale:D1.1 1/8" = 1'-0"
1 DEMOLITION FLOOR PLAN
ROOF SCUTTLE
BATHROOM
BATH
JANITOR
SUPPLY
ROOM
TRAINING
CORRIDOR
LOCKERS
GYM
KITCHEN
BOILER
RECRUITER
OFFICE
ADMIN.
OFFICE
VAULT
DRILL HALL
E101
E104
E102
E103
E105
EXIT ONLY DOOR
SECONDARY ENTRANCE DOOR
SECONDARY ENTRANCE DOOR (DELIVERIES)
PRIMARY ENTRANCE DOOR
BOILER ROOM DOOR
X
LEGEND
- DESIGNATION FOR ITEMS TO BE
REMOVED
- CONSTRUCTION NOTE. SEE
LEGEND BELOW
CONSTRUCTION NOTE LEGEND
- DESIGNATION FOR EXISTING ITEMS
TO BE REPLACED
- DESIGNATION FOR EXISTING ITEMS
TO REMAIN
1. DO NOT SCALE DRAWINGS.
2. VERIFY ALL DIMENSIONS AND CONDITIONS OF EXISTING BUILDING ELEMENTS IN THE
FIELD PRIOR TO COMMENCING WORK; NOTIFY ARCHITECT OF ANY DISCREPANCIES
DISCOVERED BEFORE PROCEEDING WITH ANY WORK.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE CAUSED BY THEIR
OPERATIONS WHILE ON SITE. ANY AND ALL DAMAGE SHALL BE REPAIRED TO THE
SATISFACTION OF THE OWNER AND ARCHITECT/ENGINEER.
4. THE CONTRACTOR SHALL PROVIDE BLOCKING FOR ALL GENERAL CONSTRUCTION
WORK AND ELECTRICAL DEVICES AS REQUIRED.
5. ALL LUMBER IN DIRECT CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED.
6. THE CONTRACTOR SHALL REVIEW, PRIOR TO INSTALLATION, ANY CONFLICT OF
ENGINEERING TRADE DEVICES WITH ARCHITECTURAL DETAILS AND BRING THOSE
DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT FOR REVIEW.
7. ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE, FACE OF MASONRY
OR CENTER OF OPENING, UNLESS OTHERWISE NOTED.
8. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATION NOT CONTAINED IN
THESE DRAWINGS.
GENERAL FLOOR PLAN NOTES
HOLLOW METAL DOOR, FRAME & HARDWARE, AS
SCHEDULED, IN EXISTING MASONRY OPENING.
2 NOT USED
BULLET RESISTANCE HOLLOW METAL DOOR, FRAME &
HARDWARE, AS SCHEDULED, IN EXISTING MASONRY
OPENING.
EXISTING ACCESS CONTROL POXIMITY READER TO REMAIN
INTERCONNECT TO ELECTRICAL DOOR LATCH RETRACTION
DEVICE
EXISTING AIPHONE TO REMAIN. INTERCONNECT TO
ELECTRICAL DOOR LATCH RETRACTION DEVICE
SHEET TITLE:
SEAL:
REVISIONS:
PROJ. NO.:
SCALE:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
ISSUE:
KEY PLAN:
SHEET INFORMATION:
PROJECT TEAM:
PROJECT INFORMATION:
As indicated
H E
A T
E R
R O
A D
L E
B A
N O
N
N H
D E
P A
R T
M E
N T
O F
M
IL
IT
A
R Y
A F
F A
IR
S
A N
D V
E T
E R
A N
S
S E
R V
IC
E
S
XX/XX/XXXX
FLOOR PLAN
A1.1
JWS
AZ
AZ
ISSUED FOR CONSTRUCTION
06/10/2026
E X
T E
R
IO
R D
O O
R U
P G
R A
D E
S
M
IN
U
T E
M A
N W
A Y
C O
N C
O R
D N
H
L E
B A
N O
N R
E A
D
IN
E S
S C
E N
T E
R
N
Scale:A1.1 1/8" = 1'-0"
1 FLOOR PLAN
14 E105 E1042 2 3
1E101 2 3
GENERAL DEMOLITION NOTES
X
LEGEND
- DESIGNATION FOR ITEMS TO BE
REMOVED
- CONSTRUCTION NOTE. SEE
LEGEND BELOW
ELEVATION CONSTRUCTION NOTE LEGEND
- DESIGNATION FOR EXISTING ITEMS
TO BE REPLACED
- DESIGNATION FOR EXISTING ITEMS
TO REMAIN
GENERAL ELEVATION NOTES
BULLET RESISTANT HOLLOW METAL DOOR, FRAME &
HARDWARE, AS SCHEDULED, IN EXISTING MASONRY
OPENING.
EXISTING PROXIMITY READER, INTERCONNECT TO
ELECTRICAL DOOR LATCH RETRACTION DEVICE.
1. PROVIDE TEMPORARY BARRICADES AND PROTECTION TO PREVENT INJURY TO
PEOPLE AND DAMAGE TO ADJACENT CONSTRUCTION TO REMAIN.
2. DURING DEMOLITION ACTIVITIES, MAINTAIN BUILDING SO IT REMAINS WATER TIGHT
AND WEATHER TIGHT.
3. UNLESS DEMOLISHED MATERIAL IS INDICATED TO REMAIN OR TO BE TURNED OVER
TO THE OWNER, REMOVE MATERIAL FROM PROJECT SITE AND DISPOSE OF
LEGALLY.
4. THE CONTRACTOR IS TO PROTECT THE EXISTING BUILDING STRUCTURE AND
FINISHES TO REMAIN.
5. WHEN UTILITY SYSTEMS NEED TO BE REMOVED, PROVIDE CAP, VALVE, PLUG, OR
SEAL TO MEET CODE REQUIREMENTS AND MAINTAIN CONTINUUM OF THE SYSTEM.
6. THE CONTRACTOR IS TO CAP AND PROTECT ALL UTILITES AS ENCOUNTERED.
7. ALL DIMENSIONS INDICATED ARE PLUS OR MINUS UNLESS OTHERWISE NOTED.
8. DEMOLITION FOR THIS PROJECT IS INDICATED, BUT NOT LIMITED, BY THAT SHOWN
ON THESE DRAWINGS, AND ANY ADDITIONAL DEMOLITION REQUIRED TO
SUCCESSFULLY COMPLETE CONSTRUCTION IS A REQUIREMENT OF THIS CONTRACT.
9. ANY EXISTING COMPONENTS, THAT INTERFERE WITH PROPOSED WORK, SHALL BE
REMOVED AND REINSTALLED AS REQUIRED.
10. DEMOLITION AND CONSTRUCTION AREAS SHALL BE BARRICADED AS NECESSARY TO
COMPLY WITH ALL LOCAL, STATE AND FEDERAL CODES AND ORDINANCES. DUST
CONTROL SYSTEMS SHALL BE INSTALLED AND REMAIN IN PLACE AS NECESSARY TO
CONTROL DUST ON THIS PROJECT UNLESS OTHERWISE NOTED.
11. PROVIDE ALL LIFTS, SHORING, BRACING, ETC., AS REQUIRED TO STABILIZE AND
PROTECT EXISTING AND ADJACENT STRUCTURES DURING CONSTRUCTION.
12. COMPLY WITH ALL FEDERAL, STATE AND LOCAL GUIDELINES AND REQUIREMENTS AT
ALL TIMES DURING THE IMPLEMENTATION OF THE WORK.
13. CONTRACTOR IS TO REMOVE & REINSTALL EXISTING CARD READER SYSTEM, WHERE
APPLICABLE.
EXISTING INTERCOM DEVICE, INTERCONNECT TO
ELECTRICAL DOOR LATCH RETRACTION DEVICE
HOLLOW METAL DOOR, FRAME & HARDWARE, AS
SCHEDULED, IN EXISTING MASONRY OPENING.
1E102
1E103 2
SHEET TITLE:
SEAL:
REVISIONS:
PROJ. NO.:
SCALE:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
ISSUE:
KEY PLAN:
SHEET INFORMATION:
PROJECT TEAM:
PROJECT INFORMATION:
As indicated
H E
A T
E R
R O
A D
L E
B A
N O
N
N H
D E
P A
R T
M E
N T
O F
M
IL
IT
A
R Y
A F
F A
IR
S
A N
D V
E T
E R
A N
S
S E
R V
IC
E
S
XX/XX/XXXX
EXTERIOR ELEVATIONS
A1.2
JWS
AZ
AZ
ISSUED FOR CONSTRUCTION
06/10/2026
E X
T E
R
IO
R D
O O
R U
P G
R A
D E
S
M
IN
U
T E
M A
N W
A Y
C O
N C
O R
D N
H
L E
B A
N O
N R
E A
D
IN
E S
S C
E N
T E
R
Scale:A1.2 1/8" = 1'-0"
4 EAST ELEVATION
Scale:A1.2 1/8" = 1'-0"
2 SOUTH ELEVATION
Scale:A1.2 1/8" = 1'-0"
3 WEST ELEVATION
Scale:A1.2 1/8" = 1'-0"
1 NORTH ELEVATION
DOOR SCHEDULE NOTES
DOOR SCHEDULE LEGEND
1. PROVIDE GLAZING PER GLAZING SCHEDULE w/ ONE-WAY VISION.
2. COORDINATE ALL HOLLOW METAL FRAME THROAT DIMENSIONS
WITH EXISTING MASONRY OPENINGS.
3. G: 3' - 0" ACTIVE LEAF, F: 2' - 4" INACTIVE LEAF
4. INSULATED DOOR
5. NO LEVER TRIM ON EXTERIOR OF DOOR
6. NOTE, ACTIVE LEAF ON LEFT FROM EXTERIOR TO PROVIDE ADA
CLEARANCE TO EXISTING PROXIMITY READER LOCATION.
7. DOOR HAS EXISTING PROXIMITY READER TO REMAIN.
8. DOOR HASA EXISTING INTERCOM WITH REMOTE DOOR RELEASE
TO REMAIN
H.M. - HOLLOW METAL
PT - PAINTED; COLOR AS SELECTED BY OWNER
HARDWARE SETS
SEE SPECIFICATION SECTION 08 71 00 FOR HARDWARE SETS.
GLAZING TYPES
SEE SPECIFICATION SECTION 08 88 53 FOR
GLAZING SCHEDULE
TYPE F TYPE G
WIDTH
H E
IG
H
T
WIDTH
H E
IG
H
T
7"
M A
X T
O V
IS
IB
LE
L
IT
E
F O
R A
D A
3'
7" 2" 2"
WIDTH
H E
IG
H
T
A2
EXIST. EXT. MASONRY WALL
& LINTELS TO REMAIN, TYPICAL U.O.N.
D O
O R
H E
IG
H
T
EXIST. METAL DOOR FRAME
TO BE REMOVED, SHOWN DOTTED
BACKER ROD & SEALANT,
TYP. EACH SIDE
A S
S C
H E
D U
L E
D
INSUL. H.M. DOOR,
AS SCHED.
5 3/4"
2"
H.M. FRAME, AS SCHED.
3"
PAINT EXIST. LINTELS
2" 1/
4"
EXIST. EXT. MASONRY WALL
TO REMAIN, TYPICAL U.O.N.
H.M. FRAME
w/EXIST. WALL-TYPE EXPANSION ANCHOR, MIN. (3) REQ'D. PER JAMB
DOOR WIDTH
EXIST. CONC. FILLED METAL DOOR FRAME
& JAMB ANCHORS TO BE REMOVED,
SHOWN DOTTED.
V .I.
F
1'
AS SCHEDULED
INSUL. H.M. DOOR,
AS SCHED.
NOTE: PORTION OF EXIST.
JAMB ANCHORS TO REMAIN
BACKER ROD & SEALANT,
TYP. EACH SIDE
5/8" 2" 3/8"
3"
3/ 4"
2"
EXIST. CONCRETE FLOOR SLAB
TO REMAIN UNDISTURBED, TYP. U.O.N.
H.M. FRAME BEYOND
INSUL. H.M. DOOR,
AS SCHED.
EXIST. EXT. MASONRY WALL BEYOND
TO REMAIN, TYPICAL U.O.N.
ALUMINUM THRESHOLD,
SET IN MASTIC
EXIST. THRESHOLD
w/SLAB ANCHOR & WEATHERSTRIPPING
TO BE REMOVED (SHOWN DOTTED)
CONDUIT & CONDUCTORS,
REPLACE FROM EXIT
DEVICE TO JUNCTION BOX
EXISTING CONDUIT TO REMAIN, REVISE
CONDUCTORS AS REQUIRED
EXIT DEVICE WITH ELR
DOOR LOOP ELEC. PASS THRU
DOOR POSITION SENSOR,
SURFACE MOUNTED
EXISTING REQUEST TO EXIT
DEVICE AND JUNCTION BOX
EXISTING JUNCTION BOX
WITH POWER TO REMAIN
CONDUIT & CONDUCTORS TO
DOOR POSITION INDICATORS
EXISTING CONDUIT AND
CONDUCTOR TO ACCESS
CONTROL SYSTEM TO
REMAIN
EXISTING BOX FOR
AIPHONE AND PROX
READER TO REMAIN
EXISTING CONDUIT TO REMAIN,
REVISED CONDUCTORS AS
REQUIRED
SHEET TITLE:
SEAL:
REVISIONS:
PROJ. NO.:
SCALE:
DESN. BY:
DRAWN BY:
CHKD BY:
ISSUE DATE:
ISSUE:
KEY PLAN:
SHEET INFORMATION:
PROJECT TEAM:
PROJECT INFORMATION:
As indicated
H E
A T
E R
R O
A D
L E
B A
N O
N
N H
D E
P A
R T
M E
N T
O F
M
IL
IT
A
R Y
A F
F A
IR
S
A N
D V
E T
E R
A N
S
S E
R V
IC
E
S
XX/XX/XXXX
DOOR SCHEDULE & DETAILS
A2.1
JWS
AZ
AZ
ISSUED FOR CONSTRUCTION
06/10/2026
E X
T E
R
IO
R D
O O
R U
P G
R A
D E
S
M
IN
U
T E
M A
N W
A Y
C O
N C
O R
D N
H
L E
B A
N O
N R
E A
D
IN
E S
S C
E N
T E
R
Scale:A2.1 1/4" = 1'-0"
4 DOOR TYPES
Scale:A2.1 1/4" = 1'-0"
5 FRAME TYPES
DOOR AND FRAME SCHEDULE
DOOR #
ROOM
NAME
DOOR FRAME DETAIL LOCATION
FUNCTION
HARDWARE
SET DOOR NOTES
DOOR
TYPE WIDTH HEIGHT THICKNESS
GLAZING
TYPE MAT. FIN.
FRAME
TYPE MAT. FIN. HEAD JAMB SILL
E101
E102
E105
ASSEMBLY HALL
ASSEMBLY HALL
BOILER ROOM
G/F(PAIR) 5' - 4" 7' - 0" 1 3/4"
1 3/4"
1 3/4"
IG-1
B.R.H.M. PT-3/PT-4
PT-3/PT-4
PT-3/PT-4
A2
A2
A2
B.R.H.M. PT-3/PT-4
PT-3/PT-4
PT-3/PT-4
1/E2.1 2/E2.1 3/E2.1 ENTRY / EXIT
ENTRY / EXIT
Scale:A2.1 3" = 1'-0"
1 HEAD DETAIL - H.M. DOOR REPLACEMENT
Scale:A2.1 3" = 1'-0"
2 JAMB DETAIL - H.M. DOOR REPLACEMENT
Scale:A2.1 3" = 1'-0"
3 THRESHOLD DETAIL - H.M. DOOR REPLACEMENT
E104
E103
ASSEMBLY HALL
CORRIDOR
G/F(PAIR)
8' - 4"6' - 0"
1 3/4"
1 3/4"
PT-3/PT-4
PT-3
A2
A2 H.M.
PT-3/PT-4
PT-3 ENTRY / EXIT
ENTRY / EXIT
EXIT ONLY
5' - 4" 7' - 0"
5' - 4" 7' - 0"
5' - 4" 7' - 0"
G/F(PAIR)
F/F(PAIR)
F/F(PAIR)
1, 2, 3, 4, 6
IG-1
IG-1 1/E2.1 2/E2.1 3/E2.1
1/E2.1 2/E2.1 3/E2.1
1/E2.1 2/E2.1 3/E2.1
1/E2.1 2/E2.1 3/E2.1
1, 2, 3, 4
1, 2, 3, 4
2, 3, 4, 5
2, 4
B.R.H.M.
B.R.H.M.
B.R.H.M.
H.M.
B.R.H.M.
B.R.H.M.
B.R.H.M.
COORDINATE
HEAD HEIGHT OF
FRAME WITH
EXISTING M.O.
Scale:A2.1 3/8" = 1'-0"
6 DOOR E104 DIAGRAM
Scale:A2.1 1" = 1'-0"
7 DOOR E104 PHOTO
| Sheets |
| A1.1 - FLOOR PLAN |
| A1.2 - EXTERIOR ELEVATIONS |
| A2.1 - DOOR SCHEDULE & DETAILS |
| COVER - COVER SHEET |
| D1.1 - DEMOLITION FLOOR PLAN |
File details come from the government source that posted it. Updated .