Attachment_6_Design Addendum No. 1.pdf
PDF 1 MB Posted
- Attached to
- Landers Library Renovation
- Solicitation number
- BPM055065
- Issued by
- Maryland
About this file
This is Design Addendum No. 1, issued February 10, 2026, for the Landers Library Renovation project at St. Mary's College of Maryland, prepared by architect Quinn Evans. The addendum clarifies, revises, and supersedes information in the original project manual and drawings. Bidders must acknowledge receipt of this addendum in their proposal submissions. The addendum includes revisions to four architectural drawings: AD101 (Demo Plan - First Floor) with added keynote D10.6 regarding removal and protection of existing glass markerboards for reinstallation; A432 (Interior Elevations) with a note added to elevation B4; A433 (Interior Elevations) with a note added to elevation B4; and A703 (Furniture & Equipment Plan - L2 West) with added sheet note 2 and keynote legend. Additionally, two specification sections are included in their entirety: Section 101100 Visual Display Units and Section 101400 Panel Signage.
Section 101100 specifies magnetic glass markerboards manufactured by Claridge Products and Equipment, Inc., with laminated low-iron glass quarter-inch thick with beveled and radiused edges, 24-gauge steel backing sheets, concealed Z-clip mounting, and included magnetic marker trays and holders. Section 101400 Panel Signage details a comprehensive 2/90 Slide Modular Sign System by 2/90 Sign Systems (Grand Rapids, Michigan), featuring interchangeable components including extruded aluminum structural rails, ABS or window inserts with various copy options (Direct Print, Laser Print, ADA Direct Print Tactile), end caps in multiple styles and colors, and plaques. The signage specifications include multiple sign types (classroom, office, permanent rooms, evacuation plan, restroom, wayfinding, and directory), typography requirements in Helvetica Regular with various sizing and color options, ADA compliance with Grade 2 Braille and minimum 5/8-inch copy for ADA applications, and installation requirements with proper alignment per location plans. The addendum includes technical specifications for materials, fabrication standards, installation procedures, and maintenance guidelines for all signage products.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
10 February 2026
4219 WOODWARD AVE, SUITE 301, DETROIT, MI 48201 313.462.2550 | WWW.QUINNEVANS.COM
WASHINGTON, DC | ANN ARBOR, MI | BALTIMORE, MD | DETROIT, MI | MADISON, WI | RICHMOND, VA
ADDENDUM NO. 1
Project: ST MAR’S COLLEGE OF MARYLAND
LANDERS LIBRARY LIBRARY RENOVATION
Bid Package ref: CONSTRUCTION DOCUMENTS - APRIL 30, 2025
1.1 PROJECT INFORMATION
A. Project Name: ST MAR’S COLLEGE OF MARYLAND – LANDERS LIBRARY
B. Owner: St. Mary’s College of Maryland
C. Architect: Quinn Evans
1.2 NOTICE TO BIDDERS
A. This Addendum serves to clarify, revise, and supersede information in the Project Manual, Drawings, and previously issued Addenda. Portions of the Addendum affecting the Contract Documents will be incorporated into the Contract by enumeration of the Addendum in the Owner/Contractor Agreement.
B. The bidder shall acknowledge receipt of this addendum in their proposal at the designated location on the Proposal Form, or their Proposal Cover if no form is defined.
1.3 ATTACHMENTS
A. Responses to Contractor/Bidder Requests for Information:
None
B. Drawings:
This Addendum includes the following revised or new drawings issued in their entirety. Drawings are clouded, identified with mark, and dated to correspond with this Addendum.
The following list includes a brief summary of revisions.
1. Architectural Drawings:
1. AD101 DEMO PLAN – FIRST FLOOR
a) KEYNOTE d10.6 ADDED
2. A432 INTERIOR ELEVATIONS
a) Note added to elevation B4
3. A433 INTERIOR ELEVATIONS
a) Note added to elevation B4
4. A703 FURNITRE & EQUIPMENT PLAN – L2 WEST
a) Sheet note 2 added
b) Keynote legend added
C. Specifications:
This Addendum includes the following revised or new specification sections issued in their entirety as attachments dated to correspond with this Addendum.
Revised sections strike out revised text with revisions text appearing bold typical.
1. SECTION 10 1423 PANEL SIGNAGE
2. SECTION 10 1100 VISUAL DISPLAY DEVICES
END OF ADDENDUM
http://www.quinnevans.com/
St. Mary's College of Maryland Landers Library Renovation
February 10, 2026 QE Project # 42137280
101100 Visual Display Units - 1
SECTION 101100
VISUAL DISPLAY UNITS
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Glass markerboards.
1.02 REFERENCE STANDARDS
A. 16 CFR 1201 - Safety Standard for Architectural Glazing Materials; Current Edition.
B. ANSI Z97.1 - American National Standard for Safety Glazing Materials Used in Buildings -
Safety Performance Specifications and Methods of Test; 2015 (Reaffirmed 2020).
C. ASTM C1172 - Standard Specification for Laminated Architectural Flat Glass; 2019.
1.03 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Product Data: Provide manufacturer's data on chalkboard, porcelain enamel steel markerboard, glass markerboard, tackboard, tackboard surface covering, trim, and accessories.
1.04 QUALITY ASSURANCE
PART 2 PRODUCTS
2.01 VISUAL DISPLAY UNITS
A. Magnetic Glass Markerboards:
1. Manufacturers:
a. Claridge Products and Equipment, Inc: www.claridgeproducts.com/#sle.
b. Substitutions: See Section 016000 - Product Requirements.
2. Glass: Laminated, low iron, 1/4 inch thick (6 mm thick), with bevel edges and radiused corners, laminated to steel backing sheet for use with magnets. Coated or treated for use as dry erase board or projection surface.
3. Glass Finish: As selected from manufacturer's full range.
4. Steel Backing Sheet Thickness: 24 gauge, 0.0239 inch (0.61 mm).
5. Size: As indicated on drawings.
6. Frame: No frame, with concealed fasteners.
7. Mounting: Concealed Z clips.
8. Accessories: Provide magnetic marker tray and magnetic marker holder.
2.02 MATERIALS
A. Float Glass: Provide float-glass-based glazing unless otherwise indicated.
1. Fully Tempered Safety Glass: Comply with ANSI Z97.1 or 16 CFR 1201 criteria for safety glazing used in hazardous locations.
B. Laminated Glass: Float glass laminated in accordance with ASTM C1172.
1. Laminated Safety Glass: Comply with ANSI Z97.1 - Class B or 16 CFR 1201 - Category I impact test requirements.
END OF SECTION
February 10, 2026 QE Project # 42137280
101400 Panel Signage - 1
SECTION 101400
PANEL SIGNAGE
PART 1 – GENERAL
1.01 DESCRIPTION
A. This section specifies interior identification, informational, directional signs, and directories.
1.02 SUBMITTALS
A. Samples: Submit one full size sample sign of the type, style, and color specified including method of attachment. If approved, the sample will become a part of the job.
B. Manufacturer’s Literature: Manufacturer’s printed specifications, mounting details, installation, and maintenance drawings.
C. Shop Drawings: Scaled for manufacturer and fabrication of sign types. Identify materials, size, typography, artwork, finishes, mounting, and accessory items.
1.03 DELIVERY AND STORAGE
A. Package to prevent damage or deterioration during shipment, handling, storage, and installation. Maintain protective coverings in place and in good repair until removal is necessary. Store products in dry condition inside enclosed facilities.
B. Deliver signs only when mounting surfaces are ready for installation work to proceed.
1.04 EXTRA MATERIALS
A. Expedited Sign Maintenance Program: Coupon books for redemption of expedited replacement Inserts and additional signage.
1.05 REFERENCES
A. Publications listed below form a part of this specification to extent referenced. Publications are referenced in text by basic designation only.
1. American National Standards Institute (ANSI) • Federal Specifications
2. American Society for Testing & Materials (ASTM) • Uniform Sign Code
1.06 WARRANTY
A. Provide manufacturer’s warranty against defect in materials. Warranty shall provide material and labor to repair or replace defective materials at the manufacturer’s discretion. Damage caused by physical or chemical abuse or damage from excessive heat will not be warranted.
Removal and reinstallation of existing signage is not warranted.
PART 2 – PRODUCTS
2.01 GENERAL
2.02 REFERENCE STANDARDS
A. UL 94 - Tests for Flammability of Plastic Materials for Parts in Devices and Appliances; Current Edition, Including All Revisions.
B. Sign and graphic components are to be by a single manufacturer, including necessary mounting options, fittings, and fastenings.
2.03 SIGN STANDARDS
A. SIGN TYPE
1. Sign Type/Part No.: Sign Type 1 (Classroom), Sign Type 2 (Office), Sign Type 3 (Permanent Rooms), Sign Type 7 (Evacuation Plan), Sign Type Elevator Flag, Sign Type Restroom Flag, Sign Type Directory with Map, Sign Type Large Wayfinding, Sign Type Small Wayfinding.
2. End Cap Style: Square Corner (SC).
3. End Cap Color: Charcoal (184)
February 10, 2026 QE Project # 42137280
101400 Panel Signage - 2
4. Mounting Option: Screw (D) or Adhesive (A), glass mounted signage to be mounted with Vinyl Glass Backers.
5. Insert Size: per plan pages.
6. Insert Color: Clear Maple (305), Charcoal (184), Pewter (154), Oyster (732).
7. Accents, Top / Bottom Trim: Accent Strip (AS) 184 Charcoal.
8. Finishes are to meet current Federal ADA and State requirements.
B. TYPOGRAPHY
1. Copy Option: ADA Direct Print (ADP), Direct Print (D2S) Laser Print (LP).
2. Copy Color: Charcoal (184), Oyster (732), Black (704).
3. Copy Style: Helvetica Regular (HRC)
4. Copy Size: Various sizing, minimum 5/8” for ADA copy, 4” Symbols.
5. Copy Position: Left Justified, Centered, and Right Justified.
6. Copy Case: All Caps (AC)
C. Note: All ADA options are standard All Caps to be compliant.
1. Copy shall be a true, clean accurate reproduction of typeface(s) specified.
2. Letter spacing and in-between line spacing shall be set by manufacturer.
3. Arrows, symbols, and logo art: To be provided in style, sizes, colors, and spacing as shown in drawings.
4. Braille: Grade 2
5. Translations: Grade 2 Braille copy, as noted in Sign Message Schedule, is responsibility of the sign manufacturer. Any second language text, as noted in Sign Message Schedule, is responsibility of the customer.
2.04 SIGN TYPES
A. General:
B. Provide products produced by 2/90 Sign Systems, 5350 Corporate Grove Blvd SE, Grand
Rapids, MI 49512, phone 800.777.4310, fax 616.656.4300.
C. Sign Type/Part No.:
1. SLIDE: Sign Type 1 (Classroom), Sign Type 2 (Office), Sign Type 3 (Permanent Rooms), Sign Type 7 (Evacuation Plan), Sign Type Elevator Flag, Sign Type Restroom Flag, Sign Type Directory with Map, Sign Type Large Wayfinding, Sign Type Small Wayfinding.
2. PLAQUES: Sign Type 4A (Men’s Restroom), Sign Type 4D (Women’s Restroom), Sign Type Stair ID, Sign Type 6 (In Case of Fire), Sign Type 11 (Max Occupancy), Sign Type Stairwell, Sign type Elevator ID, Sign Type Info/Exit, Sign Type 1G,
3. VINYL GLASS BACKERS: provided for signs applied to glass.
D. SLIDE MODULAR SIGN SYSTEM
1. The 2/90 Interchangeable Component Sign System shall be comprised of three primary components: Structural Rail, Copy Insert(s), and Interlocking End Caps or Frame.
2. Interior sign system is capable of being arranged in a variety of configurations with a minimum of attachments, devices, and connectors.
3. Interchangeable nature of the system will allow for changes of graphic components of the installed sign, without changing sign in its entirety.
4. Slide is available in two thicknesses. Standard profile is 9/16” and can accept Inserts on both sides. Thin profile is 9/32” and can only accept Inserts on one side. Thin and Standard Profiles are used in this project.
5. Slide shall allow for different mounting devices including adhesive tape, magnetic tape, hook and loop, screw, pin, freestanding, various panel hooks and ceiling options, and other mounting devices as specified. Screw (D), Adhesive (A), Perpendicular (K)
6. STRUCTURAL RAIL
a. Structural Rail utilizes horizontal rails, spaced to allow uniform, modular sizing of
Inserts. It is the internal structural member of the sign in extruded 6063-TS aluminum, anodized black.
February 10, 2026 QE Project # 42137280
101400 Panel Signage - 3
b. The Structural Rail may accept an ABS plastic, anodized aluminum, high-pressure laminate, or acrylic Insert on one or both sides, depending upon sign style.
c. Structural Rail shall allow for different mounting devices including wall mounting for screw-on applications, pressure sensitive tape, freestanding mount, fabric panel mount, ceiling mount, and other mounting devices as specified. Screw (D), Adhesive (A), Perpendicular (K).
d. Structural Rails can be converted in the field to permit a sign to be enlarged from one size to another, in height or width.
e. Rail Joiners extruded in black PVC plastic. Rail Joiners connect Structural Rails together providing a butt joint along their edges; Rail Joiners are not visible in rail assembly.
f. Accent Strips extruded in 6063-T5 aluminum also connect Structural Rails together but with a visible horizontal rib, which is seen between the adjacent Copy Inserts.
Accent Strips are satin anodized and can be color matched in painted acrylic lacquer. Accent Strip (AS) Charcoal (184)
7. COPY INSERTS
8. Copy Inserts accept various forms of copy and graphics and attach to the Structural Rail with a hook detail.
a. Copy Inserts are interchangeable by sliding horizontally from either side of sign, and to other signs in system of equal width or height.
b. Wipe clean with a damp cloth. Do not use harsh chemicals or solvents.
c. Copy Insert Materials:
1) ABS Inserts – .090” extruded ABS plastic core with .003” UV resistant acrylic cap bonded during extrusion/texturing process. Pressure bonded to extruded PVC hook using high-bond, pressure sensitive adhesive. Insert color is either integral or painted in acrylic lacquer. Finished in a Chromium industries #HM335RA texture pattern to prevent glare and disguise fingerprints.
2) Window Inserts – Extruded 6063-T5 aluminum with integral hooks for connection to Structural Rail. Color is anodized black, anodized satin, or painted acrylic lacquer. Inserts hold die-cut paper insert with a clear .020” textured polycarbonate lens.
3) ADA, Direct Print Tactile Inserts – UV/LED-cured, 1/32” thick, direct-print raised characters and fully domed, clear Grade 2 Braille dots, printed on ABS, anodized aluminum, high-pressure laminates, acrylic, or direct-print background graphics Inserts. Background color for painted materials is painted with acrylic lacquer in the specified Insert color. Copy color is UV/LED-cured inks digitally applied directly to the substrate surface.
9. INTERLOCKING END CAPS OR FRAMES
a. End Caps interlock to Structural Rail with steel spring clips to form an integral unit, enclosing and securing the changeable Copy Inserts, without requiring tools for assembly.
b. End Caps or Frames are extruded in 6063-T5 extruded aluminum or injection molded ABS. Painted with acrylic lacquer.
c. Interchangeable to either end of sign and to other signs in the system of equal height.
d. Tamper-resistant feature can be added for Thin profile by notching structural rail to accept locking tab in End Cap clip or by use of screws for Standard profile.
e. SPEC WRITER NOTE: Square Corner (SC) Charcoal (184)
10. GRAPHIC PROCESS
a. Type and symbols are to be produced in the following manner:
1) Direct Print Copy – VOC free, ultra-violet cured inks digitally applied directly to the substrate surface. SPEC WRITER NOTE: only available in matte finish. i.e.
715 Yellow is matte.
2) Laser Print Copy – Computer generated graphics laser printed on die-cut paper Insert.
February 10, 2026 QE Project # 42137280
101400 Panel Signage - 4
3) ADA, Direct Print Tactile Copy – UV/LED-cured, 1/32” thick, direct-print raised characters and fully domed, clear Grade 2 Braille dots, printed on ABS, anodized aluminum, high-pressure laminates, acrylic, or direct-print background graphics Inserts. Background color for painted materials is painted with acrylic lacquer in the specified Insert color. Copy color is UV/LED-cured inks digitally applied directly to the substrate surface.
b. TYPOGRAPHY
1) Copy Option: ADA Direct Print (ADP), Direct Print (DP), Laser Print (LP)
2) Copy Color: Charcoal (184), Oyster (732), Black (704)
3) Copy Style: Helvetica Regular
4) Copy Size: Various sizing, minimum 5/8” for ADA copy, 4” Symbols.
5) Copy Position: Left Justified, Centered, and Right Justified.
6) Copy Case: All Caps (AC)
c. Note: All ADA options are standard All Caps to be compliant.
1) Copy shall be a true, clean accurate reproduction of typeface(s) specified.
2) Letter spacing and in-between line spacing shall be set by manufacturer.
3) Arrows, symbols, and logo art: To be provided in style, sizes, colors and spacing as shown in drawings.
4) Braille: Grade 2
5) Translations: Grade 2 Braille copy, as noted in Sign Message Schedule, is responsibility of the sign manufacturer. Any second language text, as noted in Sign Message Schedule, is responsibility of the customer.
E. PLAQUES
1. A Plaque is the Copy Insert material of the 2/90 Slide Modular Sign minus the leg configuration needed to attach to the Structural Rail.
2. Plaques are not changeable.
3. Plaques shall allow for different mounting devices including pressure sensitive tape, magnetic tape, panel and tile, hook, and other mounting devices as specified. Adhesive
(A) is to be used in this project.
4. Wipe clean with a damp cloth. Do not use harsh chemicals or solvents.
5. PLAQUE MATERIALS:
a. ABS Plaque - .090” extruded ABS plastic core with .003” UV resistant acrylic cap bonded during extrusion/texturing process. Plaque color is either integral or painted in acrylic lacquer. Finished in a Chromium industries #HM335RA texture pattern to prevent glare and disguise fingerprints.
b. ADA, Direct Print Tactile Plaque – UV/LED-cured, 1/32” thick, direct-print raised characters and fully domed, clear Grade 2 Braille dots, printed on ABS, anodized aluminum, high-pressure laminates, acrylic, or direct-print background graphics Inserts. Background color for painted materials is painted with acrylic lacquer in the specified Insert color. Copy color is UV/LED-cured inks digitally applied directly to the substrate surface.
6. GRAPHIC PROCESS
a. Type and symbols are to be produced in the following manner:
1) Direct Print Copy – VOC free, ultra-violet cured inks digitally applied directly to the substrate surface.
2) ADA, Direct Print Tactile Copy – UV/LED-cured, 1/32” thick, direct-print raised characters and fully domed, clear Grade 2 Braille dots, printed on ABS, anodized aluminum, high-pressure laminates, acrylic, or direct-print background graphics Inserts. Background color for painted materials is painted with acrylic lacquer in the specified Insert color. Copy color is UV/LED-cured inks digitally applied directly to the substrate surface.
b. TYPOGRAPHY
1) Copy Option: SPEC WRITER NOTE: List Copy Option. i.e. Direct Print (DP)
2) Copy Color: SPEC WRITER NOTE: List Copy Color. i.e. White (708)
February 10, 2026 QE Project # 42137280
101400 Panel Signage - 5
3) Copy Style: SPEC WRITER NOTE: List Copy Style. i.e. Arial (ARL)
4) Copy Size: SPEC WRITER NOTE: List Copy Size. i.e. 5/8
5) Copy Position: SPEC WRITER NOTE: List Copy Position. i.e. Center (C)
6) Copy Case: SPEC WRITER NOTE: Standard Upper and Lower Case unless specified All Caps or As Typed indicated in the Sign Message Schedule. i.e. All Caps (AC)
c. Note: All ADA options are standard All Caps to be compliant.
1) Copy shall be a true, clean accurate reproduction of typeface(s) specified.
2) Letter spacing to be normal and interline spacing shall be set by manufacturer.
3) Arrows, symbols, and logo art: To be provided in style, sizes, colors, and spacing as shown in drawings.
4) Braille: Grade 2
5) Translations: Grade 2 Braille copy, as noted in Sign Message Schedule, is responsibility of the sign manufacturer. Any second language text, as noted in Sign Message Schedule, is responsibility of the customer.
2.05 FABRICATION
A. Design components allow for expansion and contraction for a minimum material temperature range of 56 degrees C 100 degrees Fahrenheit (37.78 degrees Celsius), without causing buckling, excessive opening of joints, or over stressing of adhesives and fasteners.
B. Form work to required shapes and sizes, with true curves, lines, and angles. Provide necessary rebates, lugs, and brackets for assembly of units.
C. Contact surfaces of connected members must be true. Assembled so joints will be tight and practically unnoticeable, without use of filling compound.
D. Signs shall have fine, even texture and be flat and sound. Lines and miters sharp, arises unbroken, profiles accurate and ornament true to pattern. Plane surfaces should be smooth, flat and without oil-canning, free of rack and twist. Maximum variation from plane of surface plus or minus .032”. Restore texture to filled or cut areas.
E. Level or straighten wrought work. Members shall have sharp lines and angels and smooth surfaces.
F. Extruded members to be free from extrusion marks. Square turns and corners sharp, curves true.
G. Conceal fastenings where possible. Exposed ends and edges mill smooth, with corners slightly rounded.
H. All painted surfaces properly primed. Finish coating of paint to have complete coverage with no light or thin applications allowing substrate or primer to show. Parts are checked for approval against the color match master chip. Finished surface smooth, free of scratches, gouges, drips, bubbles, thickness variations, foreign matter, and other imperfections.
I. Movable parts, including hardware, are to be cleaned and adjusted to operate as designed without binding or deformation of members. Doors and covers centered in opening of frame.
All contact surfaces fit tight and even without forcing or warping components.
J. Shop fabricates so far as practical and pre-assemble items to greatest extent possible to minimize field splicing and assembly. Disassemble units only as necessary for shipping and handling limitations. Clearly mark units for re-assembly and coordinated installation.
PART 3 – EXECUTION
3.01 INSTALLATION
A. Protect products against damage during field handling and installation. Protect adjacent existing and newly placed construction as necessary to prevent damage during installation.
Paint and touch-up any exposed fasteners and connecting hardware to match color and finish of surrounding surface.
February 10, 2026 QE Project # 42137280
101400 Panel Signage - 6
B. Mount signs in proper alignment, level and plumb according to the sign location plan and the dimensions given on elevation and sign location drawings. Where otherwise not dimensioned, signs shall be installed where best suited to provide a consistent appearance throughout the project. When exact position, angle, height or location is in doubt, contact Architect for clarification.
C. At completion of sign installation, clean exposed sign surfaces. Clean and repair any adjoining surfaces that became soiled or damaged as a result of installation of signs.
D. Locate signs as shown on the Sign Location Plan.
E. At completion of installation, turn over any additional stock of signs and sign components listed in the Sign Message Schedule.
3.02 SIGN MESSAGE SCHEDULE
A. The Sign Message Schedule and Sign Location Plans are inter-related documents. These documents represent location, type, and total number of signs required.
B. Contractors shall clarify any perceived irregularities in the Sign Message Schedule.
C. SPEC WRITER NOTE: Insert the Sign Message Schedule in this location in the specification and it should contain, at minimum, the following information.
1. Location reference number of the sign within or on the building as shown on the Sign
Location Drawing.
2. The text message, arrow, or symbol on the sign.
3. The type of sign (part number & style) to go in/on/at this specific location identified by the location reference number.
4. The size of the sign the message is to appear as shown on the Sign Location Drawings.
5. Reference to the mounting or installation requirements as shown in the drawings.
6. Any special notations or remarks providing classifications and general information regarding a specific sign at a particular location.
TECHNICAL SPECIFICATIONS
1) SLIDE MODULAR SIGN SYSTEM
A. RAILS
1. Internal Structural Rails
2. Extruded Aluminum 6063 Alloy, T-5 Temper, Anodized Black
B. INSERTS
1. ABS Inserts
2. .090” extruded ABS plastic core with .003” KORAD acrylic cap bonded during the extrusion/texturing process.
3. Painted ABS Inserts are sprayed with PPG Automotive Acrylic Lacquer. Interior and exterior applications. UV resistant. Fade resistant to 5 years.
4. Window Inserts
5. Extruded 6063-T5 aluminum with integral hooks for connection to Structural Rail. Color is anodized black, anodized satin or painted acrylic lacquer. Inserts hold die-cut paper insert with a clear .020” textured polycarbonate lens.
6. Acrylic Windows
7. .060” non-glare acrylic bonded to .030 ABS and pressure bonded to extruded hook or magnetic tape.
8. Fire Rating
9. UL 94
10. Flame Spread
11. UL94HB
12. Smoke Development
13. NVS Smoke Test/E84 Steinner Tunnel Test: 450 smoke density. Begins smoking upon ignition.
February 10, 2026 QE Project # 42137280
101400 Panel Signage - 7
14. ADA, Direct Print Tactile Inserts
15. UV/LED-cured, 1/32” thick, direct-print raised characters and fully domed, clear Grade 2
Braille dots, printed on ABS, anodized aluminum, high-pressure laminates, acrylic, or direct-print background graphics Inserts. Background color for painted materials is painted with acrylic lacquer in the specified Insert color. Copy color is UV/LED-cured inks digitally applied directly to the substrate surface.
C. END CAPS
1. ABS
2. Injection molded, Toyolac 100 General Purpose ABS plastic
3. Flammability
4. 94HB
5. Extruded Aluminum
6. Extruded aluminum 6063, T-5 Temper
7. Spring Steel Clips
8. .018” spring steel for Standard, and .020” spring steel clips for Thin, black zinc plated.
D. MOUNTS
1. Wall Mounts
2. A-Adhesive Tape for smooth, hard surfaces.
3. D-Screw for rough surfaces and all signs exceeding 100 square inches.
4. K-Perpendicular to wall. Sign is two-sided and connects to a black anodized aluminum bracket at a 90° angle.
E. TRIM
1. Extruded Aluminum
2. Extruded aluminum 6063, T-5 Temper; Finish anodized or painted acrylic lacquer.
F. COPY OPTIONS
1. First Surface Copy Options
a. Direct Print
b. Laser Print
2. ADA, Tactile Copy Option
a. ADA, Direct Print Tactile
5.02 PLAQUES
A. PLAQUE MATERIAL
1. ABS Plaque
2. .090” extruded ABS plastic core with .003” KORAD acrylic cap bonded during the extrusion/texturing process.
3. Painted ABS Plaques are sprayed with PPG Automotive Acrylic Lacquer. Interior and exterior applications. UV resistant. Fade resistant to 5 years.
4. Acrylic Windows
5. .060” non-glare acrylic bonded with .030” ABS with adhesive to .093 ABS plastic.
a. Fire Rating
1) UL 94
b. Flame Spread
1) UL94HB
c. Smoke Development
1) NVS Smoke Test/E84 Steinner Tunnel Test: 450 smoke density. Begins smoking upon ignition.
6. ADA, Direct Print Tactile Plaque
7. UV/LED-cured, 1/32” thick, direct-print raised characters and fully domed, clear Grade 2
Braille dots, printed on ABS, anodized aluminum, high-pressure laminates, acrylic, or direct-print background graphics Inserts. Background color for painted materials is painted with acrylic lacquer in the specified Insert color. Copy color is UV/LED-cured inks digitally applied directly to the substrate surface.
February 10, 2026 QE Project # 42137280
101400 Panel Signage - 8
B. MOUNTS
1. Wall Mounts
2. A-Adhesive Tape for smooth, hard surfaces.
3. D-Screw for rough surfaces and all signs exceeding 100 square inches.
C. COPY OPTIONS
1. First Surface Copy
a. Direct Print
b. 3M High Performance Cast PVC Vinyl
2. ADA, Tactile Copy
a. ADA, Direct Print Tactile
CLEANING GUIDELINES FOR 2/90 SIGNAGE PRODUCTS
FOR ROUTINE MAINTENANCE, USE A MILD CLEANSER (SUCH AS HAND SOAP OR DISH
DETERGENT) AND LUKEWARM WATER. WIPE WITH A SPONGE OR SOFT CLOTH. AFTER
WASHING AND RINSING, BLOT DRY WITH A SOFT CLOTH OR CHAMOIS.
BEFORE USING ANY OTHER CLEANING SOLUTION, ALWAYS TEST ON AN INCONSPICUOUS
AREA OF THE SIGN. APPLY THE SOLUTION TO A CLOTH RATHER THAN SPRAYING DIRECTLY
ON THE SIGN. SANITIZE ALL SURFACES WITH THE DAMP CLOTH AND BLOT DRY WITH A DRY
CLOTH OR ALLOW TO AIR DRY.
SOLVENT BASED CLEANERS CAN DEGRADE FINISHES OVER TIME. USE THE MINIMUM RATIO
OF SOLVENT TO WATER NECESSARY FOR EFFECTIVE SANITATION. ADDITIONAL CAUTION
SHOULD BE EXERCISED ESPECIALLY ON PAINTED SURFACES.
FOR SPECIAL MAINTENANCE, CALL THE CUSTOMER SERVICE DEPARTMENT. DO NOT USE
ALCOHOL OR OTHER CLEANING SOLUTIONS.
END OF SECTION
DEMOLITION LEGEND
ITEM / CONSTRUCTION
TO BE REMOVED,
SALVAGED OR
REINSTALLED
EXISTING DOOR
TO REMAIN
EXISTING CONSTRUCTION
TO REMAIN
DOOR TO BE REMOVED,
SALVAGED OR
REINSTALLED
D27.1
D27.2
D06.1
D06.1
D06.2
D06.2
TYP OF 10
THIS FLOOR
D09.1
D09.2
D09.2
D27.5
D08.3
D08.3 D06.4
D06.4
D10.2 D10.1
D10.4 D10.3 D27.6
D10.5
D06.3
D06.6
D06.6
D27.7
LINE OF WALL
ABOVE - TYP
D10.6 1
SHEET NOTES
1. COORDINATE DEMOLITION WITH NEW
WORK.
2. PROTECT ALL EXISTING FURNITURE
AND EQUIPMENT FOR REINSTALLATION
OR RETURN TO OWNER - REFER TO
DEMO FURNITURE PLANS.
3. UNO WHEREEVER NEW FLOOR
FINISHES ARE SCHEDULED, REMOVE
EXISTING FLOOR FINISH, REMOVE
EXISTING BASE & PREP SUBSTRATE
FOR NEW FLOOR FINISH. REFER TO
FINISH PLANS FOR AREAS TO RECEIVE
NEW FINISHES.
NOT IN
SCOPE
M
AI
N
EN
TR
Y
KEYPLAN
PROJECT
NORTH
0'
PA
TH
F
IL
EN
AM
E:
PL
O
TT
IN
G D
AT
E
TI
M E:
A
DRAWN BY:PROJECT MANAGER:
QUINNEVANS.COM
2101 L STREET, NW
SUITE 950
WASHINGTON, DC 20037
v 202.298.6700
M
B
C
D
E
F
G
H
J
K
L
122 3 4 5 6 7 8 9 10 11
1 122 3 4 5 6 7 8 9 10 11
2' 8' 16'4'
Au to de sk
D oc s:
//S t M ar ys C ol le ge o f M ar yl an d Li br ar y R ev /S
M C
M L ib ra ry R en ov at io n_
.rv t 2/
9/
:3 0:
P
M
AD101
DEMO PLAN - FIRST
FLOOR
AuthorChecker
QEA No.42137280
ST. MARY'S CITY, MD 20686
APRIL 30, 2025
CONSTRUCTION DOCUMENTS
LANDERS LIBRARY
RENOVATION
ST. MARY'S COLLEGE OF
MARYLAND
1/8" = 1'-0"AD101
A1 PARTIAL FIRST FLOOR DEMO PLAN - WEST
KEYNOTES
D06.1 REMOVE COUNTER AND WALL
SUPPORT BRACKETS
D06.2 REMOVE WOOD CHAIR RAIL AND
BASE AT FREESTANDING
COLUMNS - TYP
D06.3 REMOVE EXISTING MILLWORK
D06.4 REMOVE CASEWORK
D06.6 REMOVE CHAIR RAIL AND WOOD
BASE AT ELEVATOR LOBBY - TYP
D08.3 REMOVE ACCORDION DOOR
D09.1 WALL REMOVAL FOR
INSTALLATION OF NEW INTERIOR
WINDOW - COORDINATE WITH
NEW WORK
D09.2 REMOVE THINSET QUARRY TILE
IN AREA INDICATED
D10.1 REMOVE SIGNAGE
D10.2 REMOVE BULLETIN BOARD
D10.3 REMOVE HAND SANITIZER
STATION
D10.4 REMOVE PHI BETA KAPPA SIGN
AND RETURN TO OWNER -
OWNER TO CONFIRM DEMO IS
ACCEPTABLE
D10.5 REMOVE DIRECTORY
D10.6 REMOVE AND PROTECT EXISTING
GLASS MARKERBOARDS (2). FOR
REINSTALLATION. REFER TO
CONSTRUCTION ELEVATIONS
FOR NEW LOCATIONS.
D27.1 REMOVE EXISTING WALL WHILE
PROTECTING EXISTING DATA
CABLE RUN VERTICALLY
THROUGH IT
D27.2 REMOVE POTS LINES RUN IN
WALL
D27.5 PRIOR TO ANY DEMOLITION IN
THIS AREA, MEET WITH SMCM OIT
DEPARTMENT AND THEIR SUB
CONTRACTOR(S) TO CONFIRM
WHAT INFRASTRUCTURE TO
REMOVE AND THE TIMING OF ANY
INFRASTRUCTURE REMOVAL
D27.6 RELOCATE EXISTING HAND
TELEPHONE - REFER TO
CONSTRUCTION PLANS FOR NEW
LOCATION
D27.7 REMOVE DIGITAL DISPLAY
SCREEN, MOUNT, BACKBOX AND
ASSOCIATED WIRING - RETURN
TO OWNER
No. Date Description
1 10 FEB 2026 ADD 1
H
FIRST FLOOR
17' - 8"
WORLD MAP GRAPHIC
ON 25MM PET FELT
09.01
27.1
3B
3C
9'
0" 6"
2' - 5 1/16" 12' - 0" 6"
PT 3A
CREDENZA
09.02D
4' - 0" 4' - 0" 4' - 0"
FIRST FLOOR
17' - 8"
27.1
09.01
4'
0"
CREDENZA
EQEQ
G
FIRST FLOOR
17' - 8"
27.1
4'
0"
5' - 5"
FIRST FLOOR
17' - 8"
27.1
EQEQ
4'
0"
HVAC WALL
FIN UNIT
B3
A513
FIRST FLOOR
17' - 8"
27.1
EQEQ
4'
0"
H
FIRST FLOOR
17' - 8"
09.01
4A
SF02
09.01
SHEET NOTES
1.
2.
ALL WALLS ARE TO BE PAINTED (PT1)
UNO
REFER TO STOREFRONT TYPES SHEET
FOR MORE INFORMATION
G
FIRST FLOOR
17' - 8"
2A
EQ EQ
10.03D
TYPICAL WALL PAINT UNO -
BOD BM OC-17 WHITE DOVE
PAINT FINISH LEGEND
PT 1A
ACCENT WALL PAINT - YELLOW 1
(RICH) - BOD BM 378 GIBSON
GOLD
PT 2A
PT 3A
ACCENT WALL PAINT - BLUE 1
(DEEP) - BM CSP-690 HIDDEN
SAPPHIRE
PT 5
PAINT AT HOLLOW METAL FRAMES
AND PAINTED FLUSH DOORS - TO
MATCH KAWNEER PERMAFLOUR
ZINC GRAY (SHADE BETWEEN BM
HC-166 & HC 167)
PT 6 TYPICAL CEILING PAINT
BM PM-1
ACCENT WALL PAINT - YELLOW 2
(POP) - BOD BM 377 MUSTARD
FIELD
PT 2B
PT 3B ACCENT WALL PAINT - BLUE 2
(POP) - BM 749 BAINBRIDGE BLUE
PT 4
ACCENT WALL PAINT - GRAY - BM
1483 COB COB STONEWALL
CREAM WHITE WALL PAINT TO
MATCH EXISTING WALL PAINTPT 1B
PA
TH
F
IL
EN
AM
E:
PL
O
TT
IN
G D
AT
E
TI
M E:
A
DRAWN BY:PROJECT MANAGER:
QUINNEVANS.COM
2101 L STREET, NW
SUITE 950
WASHINGTON, DC 20037
v 202.298.6700
M
B
C
D
E
F
G
H
J
K
L
122 3 4 5 6 7 8 9 10 11
1 122 3 4 5 6 7 8 9 10 11
Au to de sk
D oc s:
//S t M ar ys C ol le ge o f M ar yl an d Li br ar y R ev /S
M C
M L ib ra ry R en ov at io n_
.rv t 2/
/2
9:
:4
AM
A432
INTERIOR
ELEVATIONS
AuthorChecker
QEA No.42137280
ST. MARY'S CITY, MD 20686
APRIL 30, 2025
CONSTRUCTION DOCUMENTS
LANDERS LIBRARY
RENOVATION
ST. MARY'S COLLEGE OF
MARYLAND
1/4" = 1'-0"A432
C3 INT ELEV - OIE LOBBY NORTH
1/4" = 1'-0"A432
C2 INT ELEV - OIE LOBBY WEST
1/4" = 1'-0"A432
B1 INT ELEV - OIE 122B NORTH
1/4" = 1'-0"A432
B2 INT ELEV - OIE 123B WEST
1/4" = 1'-0"A432
A2 INT ELEV - OIT DIGITAL MEDIA LAB SOUTH
1/4" = 1'-0"A432
B3 INT ELEV - OIE 122A EAST
KEYNOTES
09.01 ACOUSTIC WD SLAT WALL
CLADDING - REFER TO A1/A801
09.02D WORLD MAP GRAPHIC - CUSTOM
PRINTED WORLD MAP IMAGE ON
25MM PET FELT PANEL BOD:
ACOUFELT SOLID 25MM PANEL -
FURNISH AND INSTALL BY
OWNER'S SIGNAGE VENDOR.
10.03D RELOCATED EXISTING GLASS
MARKERBOARD - PROVIDE
BLOCKING IN WALL FOR
INSTALLATION
27.1 DISPLAY SCREEN - COORD
POWER AND DATA RECEPTACLE
LOCATIONS WITH WALL BRACKET
TO BE CONCEALED BEHIND
SCREEN - REFER TO TA
DRAWINGS AND SPECS
1/4" = 1'-0"A432
B4 INT ELEV - OIE 122A SOUTH
No. Date Description
FIRST FLOOR
17' - 8"
2'
EQEQ
27.1
1/2"3' - 0"3' - 3"3' - 3"3' - 3"3' - 3"3' - 3"3' - 0"1/2"
A4
A801
PT 2B
PL01
SS01
FIRST FLOOR
17' - 8"
I.5
EQ EQ
4'
0"
27.1
27.6
I
FIRST FLOOR
17' - 8"
OP
EN
HALF WALL FOR RUNNING
EXISTING AV/IT CABLE
EXISTING CCPD DONOR WALL
SIGNAGE - OWNER FURNISHED
OWNER INSTALLED
RECEPTION DESK FURNITURE
INSTALLED AROUND HALF
WALL BY OWNER
O
PE
N
2'
0"
FIRST FLOOR
17' - 8"
SF06
4A
B
THIRD FLOOR
45' - 0"
27.1
4'
0"
EQ EQ
HVAC WALL
FIN UNIT
3 2
THIRD FLOOR
45' - 0"
HVAC WALL
FIN UNIT
7' - 6"7' - 6"
27.1 27.1
10.03C
4'
0"
10.03C
WDW
OPPOSITE
ALIGN - TYP
SHEET NOTES
1.
2.
ALL WALLS ARE TO BE PAINTED (PT1)
UNO
REFER TO STOREFRONT TYPES SHEET
FOR MORE INFORMATION
SECOND FLOOR
31' - 0"
4'
0"
27.1
EQEQ HVAC WALL
FIN UNIT
SECOND FLOOR
31' - 0"
27.1
EQ EQ
4'
0"
J
FIRST FLOOR
17' - 8"
I.5
EQ EQ
5'
0"
HVAC WALL
FIN UNIT
10.03D
I H
FIRST FLOOR
17' - 8"
EQ EQ
4'
0"
A513 C4
27.1
OPE
N
HVAC WALL
FIN UNIT
TYPICAL WALL PAINT UNO -
BOD BM OC-17 WHITE DOVE
PAINT FINISH LEGEND
PT 1A
ACCENT WALL PAINT - YELLOW 1
(RICH) - BOD BM 378 GIBSON
GOLD
PT 2A
PT 3A
ACCENT WALL PAINT - BLUE 1
(DEEP) - BM CSP-690 HIDDEN
SAPPHIRE
PT 5
PAINT AT HOLLOW METAL FRAMES
AND PAINTED FLUSH DOORS - TO
MATCH KAWNEER PERMAFLOUR
ZINC GRAY (SHADE BETWEEN BM
HC-166 & HC 167)
PT 6 TYPICAL CEILING PAINT
BM PM-1
ACCENT WALL PAINT - YELLOW 2
(POP) - BOD BM 377 MUSTARD
FIELD
PT 2B
PT 3B ACCENT WALL PAINT - BLUE 2
(POP) - BM 749 BAINBRIDGE BLUE
PT 4
ACCENT WALL PAINT - GRAY - BM
1483 COB COB STONEWALL
CREAM WHITE WALL PAINT TO
MATCH EXISTING WALL PAINTPT 1B
PORCELIN WALL TILE - BOD
MOSA COLORS 18900-1515
CASEWORK FINISH LEGEND
CT 1
PL01
PLASTIC LAMINATE - BOD
FORMICA - HARD ROCK MAPLE
86992
WV 1 WOOD VENEER - MAPLE
GLAZING GL 1
PL02
SS01 SOLID SURFACE - BOD
CORIAN ANTARTICA
PLASTIC LAMINATE - BOD
FORMICA - GRAYSTONE 464
WD 1 SOLID WOOD - MAPLE
GYP BD - PAINTED PT-1AGYP 1
PA
TH
F
IL
EN
AM
E:
PL
O
TT
IN
G D
AT
E
TI
M E:
A
DRAWN BY:PROJECT MANAGER:
QUINNEVANS.COM
2101 L STREET, NW
SUITE 950
WASHINGTON, DC 20037
v 202.298.6700
M
B
C
D
E
F
G
H
J
K
L
122 3 4 5 6 7 8 9 10 11
1 122 3 4 5 6 7 8 9 10 11
Au to de sk
D oc s:
//S t M ar ys C ol le ge o f M ar yl an d Li br ar y R ev /S
M C
M L ib ra ry R en ov at io n_
.rv t 2/
/2
9:
:2
AM
A433
INTERIOR
ELEVATIONS
AuthorChecker
QEA No.42137280
ST. MARY'S CITY, MD 20686
APRIL 30, 2025
CONSTRUCTION DOCUMENTS
LANDERS LIBRARY
RENOVATION
ST. MARY'S COLLEGE OF
MARYLAND
1/4" = 1'-0"A433
A1 INT ELEV - CLASSROOM 312 SOUTH
1/4" = 1'-0"A433
A2 INT ELEV - CLASSROOM 312 WEST
1/4" = 1'-0"A433
B1 INT ELEV - CCPD CAREER STUDIO WEST
1/4" = 1'-0"A433
C3 INT ELEV - CONFERENCE 112 SOUTH
1/4" = 1'-0"A433
B2 INT ELEV - CCPD LOBBY SOUTH
1/4" = 1'-0"A433
B3 INT ELEV - CCPD LOBBY WEST
KEYNOTES
10.03C GLASS MARKERBOARD - 4 x 8
10.03D RELOCATED EXISTING GLASS
MARKERBOARD - PROVIDE
BLOCKING IN WALL FOR
INSTALLATION
27.1 DISPLAY SCREEN - COORD
POWER AND DATA RECEPTACLE
LOCATIONS WITH WALL BRACKET
TO BE CONCEALED BEHIND
SCREEN - REFER TO TA
DRAWINGS AND SPECS
27.6 SLIM AV CABINET - BOD: 2 BAY,
32" TALL C3 SERIES BY MIDDLE
ATLANTIC - REFER TO AV -
FURNISH AND INSTALL BY
CONTRACTOR
1/4" = 1'-0"A433
D3 INT ELEV - TYPICAL STUDY ROOM
1/4" = 1'-0"A433
D2 INT ELEV - STUDY RM 206
1/4" = 1'-0"A433
C2 INT ELEV - CONFERENCE 112 NORTH
1/4" = 1'-0"A433
C1 INT ELEV - CCPD CAREER STUDIO NORTH
No. Date Description
A703 A2
C-8
T-12
C-8C-8
C-8
T-7
T-7 C-5 C-5
C-5
C-5 C-5
C-5
RELOCATED FURNITURE
LEGEND
FURNITURE TO REMAIN
IN EXISTING LOCATION
NEW FURNITURE - IS
TAGGED
CASEWORK - NOT IN
FURNITURE CONTRACT
2'
9"
4' - 8 1/4"
2'
9"
6' - 8 1/4"
12.02A
12.02B
12.02A
26.07
26.07
26.07
26.07
26.07
T-7
C-8C-8
T-12
C-8 C-8
T-7
C-5 C-5
C-5
C-5
C-5C-5
LOUVERED CEILING WITH
CENTER ORIENTED FAN &
LIGHT PLANK - (1 OF 3)
SHEET NOTES
1. FURNITURE IS SHOWN FOR REFERENCE
ONLY AND WILL BE PROCURED UNDER A
SEPRATE CONTRACT
2. PODS ARE SHOWN FOR REFERENCE
ONLY AND WILL BE PROCURED UNDER A
SEPRATE CONTRACT
PROJECT
NORTH
0'
PA
TH
F
IL
EN
AM
E:
PL
O
TT
IN
G D
AT
E
TI
M E:
A
DRAWN BY:PROJECT MANAGER:
QUINNEVANS.COM
2101 L STREET, NW
SUITE 950
WASHINGTON, DC 20037
v 202.298.6700
M
B
C
D
E
F
G
H
J
K
L
122 3 4 5 6 7 8 9 10 11
1 122 3 4 5 6 7 8 9 10 11
2' 8' 16'4'
Au to de sk
D oc s:
//S t M ar ys C ol le ge o f M ar yl an d Li br ar y R ev /S
M C
M L ib ra ry R en ov at io n_
.rv t 2/
9/
:3 0:
P
M
A703
FURNITURE &
EQUIPMENT PLAN - L2
WEST
AuthorChecker
QEA No.42137280
ST. MARY'S CITY, MD 20686
APRIL 30, 2025
CONSTRUCTION DOCUMENTS
LANDERS LIBRARY
RENOVATION
ST. MARY'S COLLEGE OF
MARYLAND
1/8" = 1'-0"A703
A1 FURNITURE PLAN - L2 WEST
1/4" = 1'-0"A703
A2 ENLARGED PLAN @ PODS
1/4" = 1'-0"A703
A3 RCP @ PODS
No. Date Description
1 10 FEB 2026 ADD 1
KEYNOTES
12.02A 8 X 8 NOM POD
12.02B 8 X 10 NOM POD - CEILING SLATS
ONLY
26.07 OUTLET PROVIDED WITH POD
| SMCM Landers Library_Add 1 - cover |
| 101100-Visual Display Units-02-10-2026 |
| 101400-Panel Signage-02-10-2026 |
| SMCM Library Drawings - ADD 1 - 260210 |
| AD101 - DEMO PLAN - FIRST FLOOR |
| A432 - INTERIOR ELEVATIONS |
| A433 - INTERIOR ELEVATIONS |
| A703 - FURNITURE & EQUIPMENT PLAN - L2 WEST |
File details come from the government source that posted it. Updated .