Addendum No. 1 for St. Mary's College of Maryland Landers Library Renovation

This addendum document, issued by Quinn Evans architects on February 25, 2026, provides clarifications, revisions, and superseding information for the Landers Library Renovation project at St. Mary's College of Maryland located in St. Mary's City, Maryland. The addendum modifies the Construction Documents dated April 30, 2025, and includes revised architectural drawings, updated specification sections, and responses to contractor and bidder requests. Key revisions address demolition planning, interior elevations, furniture and equipment layouts, visual display units, panel signage systems, and fire detection and alarm system specifications. The addendum affects multiple building floors and includes detailed requirements for glass markerboards, modular sign systems by 2/90 Sign Systems, and fire alarm control systems with integrated voice emergency evacuation capabilities. Bidders must acknowledge receipt of this addendum in their proposals, and all revisions are marked with clouding and dated to correspond with Addendum No. 1.

The revised specifications include comprehensive technical requirements for visual display units utilizing magnetic glass markerboards with laminated low-iron glass and concealed mounting systems, and panel signage featuring the 2/90 Slide Modular Sign System with interchangeable components available in multiple configurations. The fire detection and alarm section specifies an analog, addressable type control unit with integrated voice emergency evacuation panel supporting 4,064 addresses, six notification appliance circuits expandable to 192, and connectivity for up to 31 amplifiers and 30 local operator consoles. The project requires compliance with NFPA 72, NFPA 70, ADA standards, and local Maryland codes. The specification establishes minimum 25 percent spare capacity requirements for initiating device circuits and notification appliance circuits, mandates a five-year manufacturer warranty on system components, and includes detailed submittal requirements, testing protocols, operator instruction, and maintenance contract provisions through the warranty period.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

25 February 2026

4219 WOODWARD AVE, SUITE 301, DETROIT, MI 48201 313.462.2550 | WWW.QUINNEVANS.COM

WASHINGTON, DC | ANN ARBOR, MI | BALTIMORE, MD | DETROIT, MI | MADISON, WI | RICHMOND, VA

ADDENDUM NO. 1

Project: ST MAR’S COLLEGE OF MARYLAND

LANDERS LIBRARY LIBRARY RENOVATION

Bid Package ref: CONSTRUCTION DOCUMENTS - APRIL 30, 2025

1.1 PROJECT INFORMATION

A. Project Name: ST MAR’S COLLEGE OF MARYLAND – LANDERS LIBRARY

B. Owner: St. Mary’s College of Maryland

C. Architect: Quinn Evans

1.2 NOTICE TO BIDDERS

A. This Addendum serves to clarify, revise, and supersede information in the Project Manual, Drawings, and previously issued Addenda. Portions of the Addendum affecting the Contract Documents will be incorporated into the Contract by enumeration of the Addendum in the Owner/Contractor Agreement.

B. The bidder shall acknowledge receipt of this addendum in their proposal at the designated location on the Proposal Form, or their Proposal Cover if no form is defined.

1.3 ATTACHMENTS

A. Responses to Contractor/Bidder Requests for Information:

None

B. Drawings:

This Addendum includes the following revised or new drawings issued in their entirety. Drawings are clouded, identified with mark, and dated to correspond with this Addendum.

The following list includes a brief summary of revisions.

1. Architectural Drawings:

1. AD101 DEMO PLAN – FIRST FLOOR

a) KEYNOTE d10.6 ADDED

2. G006 CONSTRUCTION TYPES

a) Detail 10 revised

3. A432 INTERIOR ELEVATIONS

a) Note added to elevation B4

4. A433 INTERIOR ELEVATIONS

a) Note added to elevation B4

5. A601 DOOR TYPES & SCHEDULES

a) Door schedule revised

6. A703 FURNITRE & EQUIPMENT PLAN – L2 WEST

a) Sheet note 2 added

b) Keynote legend added

C. Specifications:

This Addendum includes the following revised or new specification sections issued in their entirety as attachments dated to correspond with this Addendum.

Revised sections strike out revised text with revisions text appearing bold typical.

http://www.quinnevans.com/

25 February 2026

4219 WOODWARD AVE, SUITE 301, DETROIT, MI 48201 313.462.2550 | WWW.QUINNEVANS.COM

WASHINGTON, DC | ANN ARBOR, MI | BALTIMORE, MD | DETROIT, MI | MADISON, WI | RICHMOND, VA

1. SECTION 10 1423 PANEL SIGNAGE

2. SECTION 10 1100 VISUAL DISPLAY DEVICES

3. SECTION 28 4600 FIRE DETECTION AND ALARM

END OF ADDENDUM

http://www.quinnevans.com/

St. Mary's College of Maryland Landers Library Renovation

February 10, 2026 QE Project # 42137280

101100 Visual Display Units - 1

SECTION 101100

VISUAL DISPLAY UNITS

PART 1 GENERAL

1.01 SECTION INCLUDES

A. Glass markerboards.

1.02 REFERENCE STANDARDS

A. 16 CFR 1201 - Safety Standard for Architectural Glazing Materials; Current Edition.

B. ANSI Z97.1 - American National Standard for Safety Glazing Materials Used in Buildings -

Safety Performance Specifications and Methods of Test; 2015 (Reaffirmed 2020).

C. ASTM C1172 - Standard Specification for Laminated Architectural Flat Glass; 2019.

1.03 SUBMITTALS

A. See Section 013000 - Administrative Requirements, for submittal procedures.

B. Product Data: Provide manufacturer's data on chalkboard, porcelain enamel steel markerboard, glass markerboard, tackboard, tackboard surface covering, trim, and accessories.

1.04 QUALITY ASSURANCE

PART 2 PRODUCTS

2.01 VISUAL DISPLAY UNITS

A. Magnetic Glass Markerboards:

1. Manufacturers:

a. Claridge Products and Equipment, Inc: www.claridgeproducts.com/#sle.

b. Substitutions: See Section 016000 - Product Requirements.

2. Glass: Laminated, low iron, 1/4 inch thick (6 mm thick), with bevel edges and radiused corners, laminated to steel backing sheet for use with magnets. Coated or treated for use as dry erase board or projection surface.

3. Glass Finish: As selected from manufacturer's full range.

4. Steel Backing Sheet Thickness: 24 gauge, 0.0239 inch (0.61 mm).

5. Size: As indicated on drawings.

6. Frame: No frame, with concealed fasteners.

7. Mounting: Concealed Z clips.

8. Accessories: Provide magnetic marker tray and magnetic marker holder.

2.02 MATERIALS

A. Float Glass: Provide float-glass-based glazing unless otherwise indicated.

1. Fully Tempered Safety Glass: Comply with ANSI Z97.1 or 16 CFR 1201 criteria for safety glazing used in hazardous locations.

B. Laminated Glass: Float glass laminated in accordance with ASTM C1172.

1. Laminated Safety Glass: Comply with ANSI Z97.1 - Class B or 16 CFR 1201 - Category I impact test requirements.

END OF SECTION

February 10, 2026 QE Project # 42137280

101400 Panel Signage - 1

SECTION 101400

PANEL SIGNAGE

PART 1 – GENERAL

1.01 DESCRIPTION

A. This section specifies interior identification, informational, directional signs, and directories.

1.02 SUBMITTALS

A. Samples: Submit one full size sample sign of the type, style, and color specified including method of attachment. If approved, the sample will become a part of the job.

B. Manufacturer’s Literature: Manufacturer’s printed specifications, mounting details, installation, and maintenance drawings.

C. Shop Drawings: Scaled for manufacturer and fabrication of sign types. Identify materials, size, typography, artwork, finishes, mounting, and accessory items.

1.03 DELIVERY AND STORAGE

A. Package to prevent damage or deterioration during shipment, handling, storage, and installation. Maintain protective coverings in place and in good repair until removal is necessary. Store products in dry condition inside enclosed facilities.

B. Deliver signs only when mounting surfaces are ready for installation work to proceed.

1.04 EXTRA MATERIALS

A. Expedited Sign Maintenance Program: Coupon books for redemption of expedited replacement Inserts and additional signage.

1.05 REFERENCES

A. Publications listed below form a part of this specification to extent referenced. Publications are referenced in text by basic designation only.

1. American National Standards Institute (ANSI) • Federal Specifications

2. American Society for Testing & Materials (ASTM) • Uniform Sign Code

1.06 WARRANTY

A. Provide manufacturer’s warranty against defect in materials. Warranty shall provide material and labor to repair or replace defective materials at the manufacturer’s discretion. Damage caused by physical or chemical abuse or damage from excessive heat will not be warranted.

Removal and reinstallation of existing signage is not warranted.

PART 2 – PRODUCTS

2.01 GENERAL

2.02 REFERENCE STANDARDS

A. UL 94 - Tests for Flammability of Plastic Materials for Parts in Devices and Appliances; Current Edition, Including All Revisions.

B. Sign and graphic components are to be by a single manufacturer, including necessary mounting options, fittings, and fastenings.

2.03 SIGN STANDARDS

A. SIGN TYPE

1. Sign Type/Part No.: Sign Type 1 (Classroom), Sign Type 2 (Office), Sign Type 3 (Permanent Rooms), Sign Type 7 (Evacuation Plan), Sign Type Elevator Flag, Sign Type Restroom Flag, Sign Type Directory with Map, Sign Type Large Wayfinding, Sign Type Small Wayfinding.

2. End Cap Style: Square Corner (SC).

3. End Cap Color: Charcoal (184)

February 10, 2026 QE Project # 42137280

101400 Panel Signage - 2

4. Mounting Option: Screw (D) or Adhesive (A), glass mounted signage to be mounted with Vinyl Glass Backers.

5. Insert Size: per plan pages.

6. Insert Color: Clear Maple (305), Charcoal (184), Pewter (154), Oyster (732).

7. Accents, Top / Bottom Trim: Accent Strip (AS) 184 Charcoal.

8. Finishes are to meet current Federal ADA and State requirements.

B. TYPOGRAPHY

1. Copy Option: ADA Direct Print (ADP), Direct Print (D2S) Laser Print (LP).

2. Copy Color: Charcoal (184), Oyster (732), Black (704).

3. Copy Style: Helvetica Regular (HRC)

4. Copy Size: Various sizing, minimum 5/8” for ADA copy, 4” Symbols.

5. Copy Position: Left Justified, Centered, and Right Justified.

6. Copy Case: All Caps (AC)

C. Note: All ADA options are standard All Caps to be compliant.

1. Copy shall be a true, clean accurate reproduction of typeface(s) specified.

2. Letter spacing and in-between line spacing shall be set by manufacturer.

3. Arrows, symbols, and logo art: To be provided in style, sizes, colors, and spacing as shown in drawings.

4. Braille: Grade 2

5. Translations: Grade 2 Braille copy, as noted in Sign Message Schedule, is responsibility of the sign manufacturer. Any second language text, as noted in Sign Message Schedule, is responsibility of the customer.

2.04 SIGN TYPES

A. General:

B. Provide products produced by 2/90 Sign Systems, 5350 Corporate Grove Blvd SE, Grand

Rapids, MI 49512, phone 800.777.4310, fax 616.656.4300.

C. Sign Type/Part No.:

1. SLIDE: Sign Type 1 (Classroom), Sign Type 2 (Office), Sign Type 3 (Permanent Rooms), Sign Type 7 (Evacuation Plan), Sign Type Elevator Flag, Sign Type Restroom Flag, Sign Type Directory with Map, Sign Type Large Wayfinding, Sign Type Small Wayfinding.

2. PLAQUES: Sign Type 4A (Men’s Restroom), Sign Type 4D (Women’s Restroom), Sign Type Stair ID, Sign Type 6 (In Case of Fire), Sign Type 11 (Max Occupancy), Sign Type Stairwell, Sign type Elevator ID, Sign Type Info/Exit, Sign Type 1G,

3. VINYL GLASS BACKERS: provided for signs applied to glass.

D. SLIDE MODULAR SIGN SYSTEM

1. The 2/90 Interchangeable Component Sign System shall be comprised of three primary components: Structural Rail, Copy Insert(s), and Interlocking End Caps or Frame.

2. Interior sign system is capable of being arranged in a variety of configurations with a minimum of attachments, devices, and connectors.

3. Interchangeable nature of the system will allow for changes of graphic components of the installed sign, without changing sign in its entirety.

4. Slide is available in two thicknesses. Standard profile is 9/16” and can accept Inserts on both sides. Thin profile is 9/32” and can only accept Inserts on one side. Thin and Standard Profiles are used in this project.

5. Slide shall allow for different mounting devices including adhesive tape, magnetic tape, hook and loop, screw, pin, freestanding, various panel hooks and ceiling options, and other mounting devices as specified. Screw (D), Adhesive (A), Perpendicular (K)

6. STRUCTURAL RAIL

a. Structural Rail utilizes horizontal rails, spaced to allow uniform, modular sizing of

Inserts. It is the internal structural member of the sign in extruded 6063-TS aluminum, anodized black.

February 10, 2026 QE Project # 42137280

101400 Panel Signage - 3

b. The Structural Rail may accept an ABS plastic, anodized aluminum, high-pressure laminate, or acrylic Insert on one or both sides, depending upon sign style.

c. Structural Rail shall allow for different mounting devices including wall mounting for screw-on applications, pressure sensitive tape, freestanding mount, fabric panel mount, ceiling mount, and other mounting devices as specified. Screw (D), Adhesive (A), Perpendicular (K).

d. Structural Rails can be converted in the field to permit a sign to be enlarged from one size to another, in height or width.

e. Rail Joiners extruded in black PVC plastic. Rail Joiners connect Structural Rails together providing a butt joint along their edges; Rail Joiners are not visible in rail assembly.

f. Accent Strips extruded in 6063-T5 aluminum also connect Structural Rails together but with a visible horizontal rib, which is seen between the adjacent Copy Inserts.

Accent Strips are satin anodized and can be color matched in painted acrylic lacquer. Accent Strip (AS) Charcoal (184)

7. COPY INSERTS

8. Copy Inserts accept various forms of copy and graphics and attach to the Structural Rail with a hook detail.

a. Copy Inserts are interchangeable by sliding horizontally from either side of sign, and to other signs in system of equal width or height.

b. Wipe clean with a damp cloth. Do not use harsh chemicals or solvents.

c. Copy Insert Materials:

1) ABS Inserts – .090” extruded ABS plastic core with .003” UV resistant acrylic cap bonded during extrusion/texturing process. Pressure bonded to extruded PVC hook using high-bond, pressure sensitive adhesive. Insert color is either integral or painted in acrylic lacquer. Finished in a Chromium industries #HM335RA texture pattern to prevent glare and disguise fingerprints.

2) Window Inserts – Extruded 6063-T5 aluminum with integral hooks for connection to Structural Rail. Color is anodized black, anodized satin, or painted acrylic lacquer. Inserts hold die-cut paper insert with a clear .020” textured polycarbonate lens.

3) ADA, Direct Print Tactile Inserts – UV/LED-cured, 1/32” thick, direct-print raised characters and fully domed, clear Grade 2 Braille dots, printed on ABS, anodized aluminum, high-pressure laminates, acrylic, or direct-print background graphics Inserts. Background color for painted materials is painted with acrylic lacquer in the specified Insert color. Copy color is UV/LED-cured inks digitally applied directly to the substrate surface.

9. INTERLOCKING END CAPS OR FRAMES

a. End Caps interlock to Structural Rail with steel spring clips to form an integral unit, enclosing and securing the changeable Copy Inserts, without requiring tools for assembly.

b. End Caps or Frames are extruded in 6063-T5 extruded aluminum or injection molded ABS. Painted with acrylic lacquer.

c. Interchangeable to either end of sign and to other signs in the system of equal height.

d. Tamper-resistant feature can be added for Thin profile by notching structural rail to accept locking tab in End Cap clip or by use of screws for Standard profile.

e. SPEC WRITER NOTE: Square Corner (SC) Charcoal (184)

10. GRAPHIC PROCESS

a. Type and symbols are to be produced in the following manner:

1) Direct Print Copy – VOC free, ultra-violet cured inks digitally applied directly to the substrate surface. SPEC WRITER NOTE: only available in matte finish. i.e.

715 Yellow is matte.

2) Laser Print Copy – Computer generated graphics laser printed on die-cut paper Insert.

February 10, 2026 QE Project # 42137280

101400 Panel Signage - 4

3) ADA, Direct Print Tactile Copy – UV/LED-cured, 1/32” thick, direct-print raised characters and fully domed, clear Grade 2 Braille dots, printed on ABS, anodized aluminum, high-pressure laminates, acrylic, or direct-print background graphics Inserts. Background color for painted materials is painted with acrylic lacquer in the specified Insert color. Copy color is UV/LED-cured inks digitally applied directly to the substrate surface.

b. TYPOGRAPHY

1) Copy Option: ADA Direct Print (ADP), Direct Print (DP), Laser Print (LP)

2) Copy Color: Charcoal (184), Oyster (732), Black (704)

3) Copy Style: Helvetica Regular

4) Copy Size: Various sizing, minimum 5/8” for ADA copy, 4” Symbols.

5) Copy Position: Left Justified, Centered, and Right Justified.

6) Copy Case: All Caps (AC)

c. Note: All ADA options are standard All Caps to be compliant.

1) Copy shall be a true, clean accurate reproduction of typeface(s) specified.

2) Letter spacing and in-between line spacing shall be set by manufacturer.

3) Arrows, symbols, and logo art: To be provided in style, sizes, colors and spacing as shown in drawings.

4) Braille: Grade 2

5) Translations: Grade 2 Braille copy, as noted in Sign Message Schedule, is responsibility of the sign manufacturer. Any second language text, as noted in Sign Message Schedule, is responsibility of the customer.

E. PLAQUES

1. A Plaque is the Copy Insert material of the 2/90 Slide Modular Sign minus the leg configuration needed to attach to the Structural Rail.

2. Plaques are not changeable.

3. Plaques shall allow for different mounting devices including pressure sensitive tape, magnetic tape, panel and tile, hook, and other mounting devices as specified. Adhesive

(A) is to be used in this project.

4. Wipe clean with a damp cloth. Do not use harsh chemicals or solvents.

5. PLAQUE MATERIALS:

a. ABS Plaque - .090” extruded ABS plastic core with .003” UV resistant acrylic cap bonded during extrusion/texturing process. Plaque color is either integral or painted in acrylic lacquer. Finished in a Chromium industries #HM335RA texture pattern to prevent glare and disguise fingerprints.

b. ADA, Direct Print Tactile Plaque – UV/LED-cured, 1/32” thick, direct-print raised characters and fully domed, clear Grade 2 Braille dots, printed on ABS, anodized aluminum, high-pressure laminates, acrylic, or direct-print background graphics Inserts. Background color for painted materials is painted with acrylic lacquer in the specified Insert color. Copy color is UV/LED-cured inks digitally applied directly to the substrate surface.

6. GRAPHIC PROCESS

a. Type and symbols are to be produced in the following manner:

1) Direct Print Copy – VOC free, ultra-violet cured inks digitally applied directly to the substrate surface.

2) ADA, Direct Print Tactile Copy – UV/LED-cured, 1/32” thick, direct-print raised characters and fully domed, clear Grade 2 Braille dots, printed on ABS, anodized aluminum, high-pressure laminates, acrylic, or direct-print background graphics Inserts. Background color for painted materials is painted with acrylic lacquer in the specified Insert color. Copy color is UV/LED-cured inks digitally applied directly to the substrate surface.

b. TYPOGRAPHY

1) Copy Option: SPEC WRITER NOTE: List Copy Option. i.e. Direct Print (DP)

2) Copy Color: SPEC WRITER NOTE: List Copy Color. i.e. White (708)

February 10, 2026 QE Project # 42137280

101400 Panel Signage - 5

3) Copy Style: SPEC WRITER NOTE: List Copy Style. i.e. Arial (ARL)

4) Copy Size: SPEC WRITER NOTE: List Copy Size. i.e. 5/8

5) Copy Position: SPEC WRITER NOTE: List Copy Position. i.e. Center (C)

6) Copy Case: SPEC WRITER NOTE: Standard Upper and Lower Case unless specified All Caps or As Typed indicated in the Sign Message Schedule. i.e. All Caps (AC)

c. Note: All ADA options are standard All Caps to be compliant.

1) Copy shall be a true, clean accurate reproduction of typeface(s) specified.

2) Letter spacing to be normal and interline spacing shall be set by manufacturer.

3) Arrows, symbols, and logo art: To be provided in style, sizes, colors, and spacing as shown in drawings.

4) Braille: Grade 2

5) Translations: Grade 2 Braille copy, as noted in Sign Message Schedule, is responsibility of the sign manufacturer. Any second language text, as noted in Sign Message Schedule, is responsibility of the customer.

2.05 FABRICATION

A. Design components allow for expansion and contraction for a minimum material temperature range of 56 degrees C 100 degrees Fahrenheit (37.78 degrees Celsius), without causing buckling, excessive opening of joints, or over stressing of adhesives and fasteners.

B. Form work to required shapes and sizes, with true curves, lines, and angles. Provide necessary rebates, lugs, and brackets for assembly of units.

C. Contact surfaces of connected members must be true. Assembled so joints will be tight and practically unnoticeable, without use of filling compound.

D. Signs shall have fine, even texture and be flat and sound. Lines and miters sharp, arises unbroken, profiles accurate and ornament true to pattern. Plane surfaces should be smooth, flat and without oil-canning, free of rack and twist. Maximum variation from plane of surface plus or minus .032”. Restore texture to filled or cut areas.

E. Level or straighten wrought work. Members shall have sharp lines and angels and smooth surfaces.

F. Extruded members to be free from extrusion marks. Square turns and corners sharp, curves true.

G. Conceal fastenings where possible. Exposed ends and edges mill smooth, with corners slightly rounded.

H. All painted surfaces properly primed. Finish coating of paint to have complete coverage with no light or thin applications allowing substrate or primer to show. Parts are checked for approval against the color match master chip. Finished surface smooth, free of scratches, gouges, drips, bubbles, thickness variations, foreign matter, and other imperfections.

I. Movable parts, including hardware, are to be cleaned and adjusted to operate as designed without binding or deformation of members. Doors and covers centered in opening of frame.

All contact surfaces fit tight and even without forcing or warping components.

J. Shop fabricates so far as practical and pre-assemble items to greatest extent possible to minimize field splicing and assembly. Disassemble units only as necessary for shipping and handling limitations. Clearly mark units for re-assembly and coordinated installation.

PART 3 – EXECUTION

3.01 INSTALLATION

A. Protect products against damage during field handling and installation. Protect adjacent existing and newly placed construction as necessary to prevent damage during installation.

Paint and touch-up any exposed fasteners and connecting hardware to match color and finish of surrounding surface.

February 10, 2026 QE Project # 42137280

101400 Panel Signage - 6

B. Mount signs in proper alignment, level and plumb according to the sign location plan and the dimensions given on elevation and sign location drawings. Where otherwise not dimensioned, signs shall be installed where best suited to provide a consistent appearance throughout the project. When exact position, angle, height or location is in doubt, contact Architect for clarification.

C. At completion of sign installation, clean exposed sign surfaces. Clean and repair any adjoining surfaces that became soiled or damaged as a result of installation of signs.

D. Locate signs as shown on the Sign Location Plan.

E. At completion of installation, turn over any additional stock of signs and sign components listed in the Sign Message Schedule.

3.02 SIGN MESSAGE SCHEDULE

A. The Sign Message Schedule and Sign Location Plans are inter-related documents. These documents represent location, type, and total number of signs required.

B. Contractors shall clarify any perceived irregularities in the Sign Message Schedule.

C. SPEC WRITER NOTE: Insert the Sign Message Schedule in this location in the specification and it should contain, at minimum, the following information.

1. Location reference number of the sign within or on the building as shown on the Sign

Location Drawing.

2. The text message, arrow, or symbol on the sign.

3. The type of sign (part number & style) to go in/on/at this specific location identified by the location reference number.

4. The size of the sign the message is to appear as shown on the Sign Location Drawings.

5. Reference to the mounting or installation requirements as shown in the drawings.

6. Any special notations or remarks providing classifications and general information regarding a specific sign at a particular location.

TECHNICAL SPECIFICATIONS

1) SLIDE MODULAR SIGN SYSTEM

A. RAILS

1. Internal Structural Rails

2. Extruded Aluminum 6063 Alloy, T-5 Temper, Anodized Black

B. INSERTS

1. ABS Inserts

2. .090” extruded ABS plastic core with .003” KORAD acrylic cap bonded during the extrusion/texturing process.

3. Painted ABS Inserts are sprayed with PPG Automotive Acrylic Lacquer. Interior and exterior applications. UV resistant. Fade resistant to 5 years.

4. Window Inserts

5. Extruded 6063-T5 aluminum with integral hooks for connection to Structural Rail. Color is anodized black, anodized satin or painted acrylic lacquer. Inserts hold die-cut paper insert with a clear .020” textured polycarbonate lens.

6. Acrylic Windows

7. .060” non-glare acrylic bonded to .030 ABS and pressure bonded to extruded hook or magnetic tape.

8. Fire Rating

9. UL 94

10. Flame Spread

11. UL94HB

12. Smoke Development

13. NVS Smoke Test/E84 Steinner Tunnel Test: 450 smoke density. Begins smoking upon ignition.

February 10, 2026 QE Project # 42137280

101400 Panel Signage - 7

14. ADA, Direct Print Tactile Inserts

15. UV/LED-cured, 1/32” thick, direct-print raised characters and fully domed, clear Grade 2

Braille dots, printed on ABS, anodized aluminum, high-pressure laminates, acrylic, or direct-print background graphics Inserts. Background color for painted materials is painted with acrylic lacquer in the specified Insert color. Copy color is UV/LED-cured inks digitally applied directly to the substrate surface.

C. END CAPS

1. ABS

2. Injection molded, Toyolac 100 General Purpose ABS plastic

3. Flammability

4. 94HB

5. Extruded Aluminum

6. Extruded aluminum 6063, T-5 Temper

7. Spring Steel Clips

8. .018” spring steel for Standard, and .020” spring steel clips for Thin, black zinc plated.

D. MOUNTS

1. Wall Mounts

2. A-Adhesive Tape for smooth, hard surfaces.

3. D-Screw for rough surfaces and all signs exceeding 100 square inches.

4. K-Perpendicular to wall. Sign is two-sided and connects to a black anodized aluminum bracket at a 90° angle.

E. TRIM

1. Extruded Aluminum

2. Extruded aluminum 6063, T-5 Temper; Finish anodized or painted acrylic lacquer.

F. COPY OPTIONS

1. First Surface Copy Options

a. Direct Print

b. Laser Print

2. ADA, Tactile Copy Option

a. ADA, Direct Print Tactile

5.02 PLAQUES

A. PLAQUE MATERIAL

1. ABS Plaque

2. .090” extruded ABS plastic core with .003” KORAD acrylic cap bonded during the extrusion/texturing process.

3. Painted ABS Plaques are sprayed with PPG Automotive Acrylic Lacquer. Interior and exterior applications. UV resistant. Fade resistant to 5 years.

4. Acrylic Windows

5. .060” non-glare acrylic bonded with .030” ABS with adhesive to .093 ABS plastic.

a. Fire Rating

1) UL 94

b. Flame Spread

1) UL94HB

c. Smoke Development

1) NVS Smoke Test/E84 Steinner Tunnel Test: 450 smoke density. Begins smoking upon ignition.

6. ADA, Direct Print Tactile Plaque

7. UV/LED-cured, 1/32” thick, direct-print raised characters and fully domed, clear Grade 2

Braille dots, printed on ABS, anodized aluminum, high-pressure laminates, acrylic, or direct-print background graphics Inserts. Background color for painted materials is painted with acrylic lacquer in the specified Insert color. Copy color is UV/LED-cured inks digitally applied directly to the substrate surface.

February 10, 2026 QE Project # 42137280

101400 Panel Signage - 8

B. MOUNTS

1. Wall Mounts

2. A-Adhesive Tape for smooth, hard surfaces.

3. D-Screw for rough surfaces and all signs exceeding 100 square inches.

C. COPY OPTIONS

1. First Surface Copy

a. Direct Print

b. 3M High Performance Cast PVC Vinyl

2. ADA, Tactile Copy

a. ADA, Direct Print Tactile

CLEANING GUIDELINES FOR 2/90 SIGNAGE PRODUCTS

FOR ROUTINE MAINTENANCE, USE A MILD CLEANSER (SUCH AS HAND SOAP OR DISH

DETERGENT) AND LUKEWARM WATER. WIPE WITH A SPONGE OR SOFT CLOTH. AFTER

WASHING AND RINSING, BLOT DRY WITH A SOFT CLOTH OR CHAMOIS.

BEFORE USING ANY OTHER CLEANING SOLUTION, ALWAYS TEST ON AN INCONSPICUOUS

AREA OF THE SIGN. APPLY THE SOLUTION TO A CLOTH RATHER THAN SPRAYING DIRECTLY

ON THE SIGN. SANITIZE ALL SURFACES WITH THE DAMP CLOTH AND BLOT DRY WITH A DRY

CLOTH OR ALLOW TO AIR DRY.

SOLVENT BASED CLEANERS CAN DEGRADE FINISHES OVER TIME. USE THE MINIMUM RATIO

OF SOLVENT TO WATER NECESSARY FOR EFFECTIVE SANITATION. ADDITIONAL CAUTION

SHOULD BE EXERCISED ESPECIALLY ON PAINTED SURFACES.

FOR SPECIAL MAINTENANCE, CALL THE CUSTOMER SERVICE DEPARTMENT. DO NOT USE

ALCOHOL OR OTHER CLEANING SOLUTIONS.

February 21, 2025 QE Project # 42137280

28 4600 Fire Detection and Alarm - 1

SECTION 28 4600 - FIRE DETECTION AND ALARM

PART 1 GENERAL

1.1 SECTION INCLUDES

A. Fire alarm system design and installation, including all components, wiring, and conduit.

B. Transmitters for communication with supervising station.

C. Replacement and removal of existing fire alarm system components, wiring, and conduit indicated.

D. Maintenance of fire alarm system under contract for specified warranty period.

1.2 RELATED REQUIREMENTS

A. Section 07 8400 - Firestopping: Materials and methods for work to be performed by this installer.

B. Designed using manufacturer's product-specific design software or based on manufacturer's pre-engineered design suitable for the application.

C. Section 21 1300 - Fire-Suppression Sprinkler Systems: Supervisory, alarm, and actuating devices installed in sprinkler system.

D. Section 21 2200 - Clean-Agent Fire-Extinguishing System: Supervisory, alarm, and releasing devices installed in extinguishing system.

E. Section 23 3300 - Air Duct Accessories: Smoke dampers monitored and controlled by fire alarm system.

1.3 REFERENCE STANDARDS

A. 36 CFR 1191 - Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines; current edition.

B. ADA Standards - 2010 ADA Standards for Accessible Design; 2010.

C. IEEE C62.41.2 - IEEE Recommended Practice on Characterization of Surges in Low-Voltage (1000 V and less) AC Power Circuits; 2002 (Corrigendum 2012).

D. NFPA 70 - National Electrical Code; Most Recent Edition Adopted by Authority Having Jurisdiction, Including All Applicable Amendments and Supplements.

E. NFPA 72 - National Fire Alarm and Signaling Code; Most Recent Edition Cited by Referring Code or Reference Standard.

F. NFPA 101 - Life Safety Code; Most Recent Edition Adopted by Authority Having Jurisdiction, Including All Applicable Amendments and Supplements.

G. NFPA 601 - Standard for Security Services in Fire Loss Prevention; 2020.

April 30, 2025

February 21, 2025 QE Project # 42137280

28 4600 Fire Detection and Alarm - 2

1.4 SUBMITTALS

A. See Section 01 3000 - Administrative Requirements, for submittal procedures.

B. Selections: Highlight selected items in submittal pages and cross out items not included in the project.

C. Action Submittal: Provide a single submittal including all requirements below for all items in Part 2.

1. Compliance: Provide copy of specification section indicating compliance or non-compliance with each requirement in Part 2. Provide explanations for items not complying with the specifications.

2. Delegated Design: Provide signed and sealed design drawings, calculations, specifications, certifications, shop drawings and other documents necessary for a complete system, prepared by an appropriately licensed design professional, for the limited purpose of assessing compliance with information given and the design concept expressed in the Contract Documents.

3. Evidence of designer qualifications.

4. Design Documents: Submit all information required for plan review and permitting by authorities having jurisdiction, including but not limited to floor plans, riser diagrams, and description of operation:

a. Copy of list of data required by authority having jurisdiction.

b. NFPA 72 "Record of Completion", filled out to the extent known at the time.

c. Clear and concise description of operation, with input/output matrix similar to that shown in NFPA 72 Appendix A-7-5-2.2(9), and complete listing of software required.

d. System zone boundaries and interfaces to fire safety systems.

e. Location of all components, circuits, and raceways; mark components with identifiers used in control unit programming.

f. Circuit layouts; number, size, and type of raceways and conductors; conduit fill calculations; spare capacity calculations; notification appliance circuit voltage drop calculations.

g. List of all devices on each signaling line circuit, with spare capacity indicated.

h. Manufacturer's detailed data sheet for each component, including wiring diagrams, installation instructions, and circuit length limitations.

i. Description of power supplies; if secondary power is by battery include calculations demonstrating adequate battery power.

j. Detailed drawing of graphic annunciator(s).

k. Certification by either the manufacturer of the control unit or by the manufacturer of each other component that the components are compatible with the control unit.

l. Certification by the manufacturer of the control unit that the system design complies with Contract Documents.

m. Certification by Contractor that the system design complies with Contract

Documents.

n. Do not show existing components to be removed.

5. Evidence of installer qualifications.

6. Evidence of instructor qualifications; training lesson plan outline.

7. Evidence of maintenance contractor qualifications, if different from installer.

D. Closeout Submittal: Provide a single submittal containing all Division 26 closeout requirements, including the requirements below. Provide separate tabs and bookmarks for each specification section. Comply with all Division 01 requirements.

1. Include contents of action submittal with all review comments incorporated.

February 21, 2025 QE Project # 42137280

28 4600 Fire Detection and Alarm - 3

2. Inspection and Test Reports:

a. Submit documentation of satisfactory inspections and tests.

b. Submit NFPA 72 "Inspection and Test Form," filled out.

3. Operating and Maintenance Data: See Section 01 7800 for additional requirements;

revise and resubmit until acceptable; have one set available during closeout demonstration:

a. Complete set of specified design documents, as approved by authority having jurisdiction.

b. Contact information for firm that will be providing contract maintenance and trouble call-back service.

c. List of recommended spare parts, tools, and instruments for testing.

d. Replacement parts list with current prices, and source of supply.

e. Detailed troubleshooting guide and large scale input/output matrix.

f. Preventive maintenance, inspection, and testing schedule complying with NFPA

72; provide copy and computer format acceptable to Owner.

g. Detailed but easy to read explanation of procedures to be taken by non-technical administrative personnel in the event of system trouble, when routine testing is being conducted, for fire drills, and when entering into contracts for remodeling.

4. Certification Documents:

a. Certification by manufacturer that the system has been installed in compliance with manufacturer's installation requirements, is complete, and is in satisfactory operating condition.

b. NFPA 72 "Record of Completion", filled out completely and signed by installer and authorized representative of authority having jurisdiction.

c. Certificate of Occupancy.

d. Maintenance contract.

e. Report on training results.

E. Project Record Documents: See Section 01 7800 for additional requirements; have one set available during closeout demonstration:

1. Complete set of floor plans showing actual installed locations of components, conduit, and zones.

2. "As installed" wiring and schematic diagrams, with final terminal identifications.

3. "As programmed" operating sequences, including control events by device, updated input/output chart, and voice messages by event.

F. Maintenance Materials, Tools, and Software: Furnish the following for Owner's use in maintenance of project.

1. See Section 01 6000 - Product Requirements, for additional provisions.

2. Furnish spare parts of same manufacturer and model as those installed; deliver in original packaging, labeled in same manner as in operating and maintenance data and place in spare parts cabinet.

3. In addition to the items in quantities indicated in PART 2, furnish the following:

a. All tools, software, and documentation necessary to modify the fire alarm system using Owner's personnel; minimum modification capability to include addition and deletion of devices, circuits, and zones, and changes to system description, operation, and evacuation and instructional messages.

b. One copy, on CD-ROM, of all software not resident in read-only-memory.

c. Extra Fuses: Two for each installed fuse; store inside applicable control cabinet.

February 21, 2025 QE Project # 42137280

28 4600 Fire Detection and Alarm - 4

1.5 QUALITY ASSURANCE

A. Copies of Design Criteria Documents: Maintain at the project site for the duration of the project, bound together, an original copy of NFPA 72, the relevant portions of applicable codes, and instructions and guidelines of authorities having jurisdiction; deliver to Owner upon completion.

B. Designer Qualifications: NICET Level III or IV (3 or 4) certified fire alarm technician or registered fire protection engineer, employed by fire alarm control panel manufacturer, Contractor, or installer , with experience designing fire alarm systems in the jurisdictional area of the authorities having jurisdiction.

C. Installer Qualifications: Firm with minimum 3 years documented experience installing fire alarm systems of the specified type and providing contract maintenance service as a regular part of their business.

1. Authorized representative of control unit manufacturer; submit manufacturer's certification that installer is authorized; include name and title of manufacturer's representative making certification.

2. Installer Personnel: At least 2 years of experience installing fire alarm systems.

3. Supervisor: NICET level III or IV (3 or 4) certified fire alarm technician; furnish name and address.

4. Contract maintenance office located within 50 miles of project site.

5. Certified in the State in which the Project is located as fire alarm installer.

D. Maintenance Contractor Qualifications: Same entity as installer or different entity with specified qualifications.

E. Instructor Qualifications: Experienced in technical instruction, understanding fire alarm theory, and able to provide the required training; trained by fire alarm control unit manufacturer.

F. Product Listing Organization Qualifications: An organization recognized by OSHA as a Nationally Recognized Testing Laboratory (NRTL) and acceptable to authorities having jurisdiction.

1.6 WARRANTY

A. See Section 01 7800 - Closeout Submittals, for additional warranty requirements.

B. Provide control panel manufacturer's warranty that system components other than wire and conduit are free from defects and will remain so for 5 years after date of Substantial Completion.

C. Provide installer's warranty that the installation is free from defects and will remain so for 5 years after date of Substantial Completion.

PART 2 PRODUCTS

2.1 MANUFACTURERS

A. Fire Alarm Control Units and Accessories:

1. Bosch Security Systems, Inc.

2. Carrier/Edwards.

3. Honeywell Security & Fire Solutions/Gamewell-FCI.

4. Honeywell Security & Fire Solutions/Fire-Lite.

5. Honeywell Security & Fire Solutions/Notifier.

February 21, 2025 QE Project # 42137280

28 4600 Fire Detection and Alarm - 5

6. Honeywell Security & Fire Solutions/Silent Knight.

7. Honeywell Security & Fire Solutions/Vista.

8. Mircom Technologies, Ltd.

9. Potter Electric Signal Company.

10. Siemens Building Technologies, Inc.

11. Simplex, a brand of Johnson Controls.

12. Provide control units and accessories made by the same manufacturer.

B. Initiating Devices and Notification Appliances:

1. Bosch Security Systems, Inc.

2. Carrier/Edwards.

3. Honeywell Security & Fire Solutions/Gamewell-FCI.

4. Honeywell Security & Fire Solutions/Fire-Lite.

5. Honeywell Security & Fire Solutions/Notifier.

6. Honeywell Security & Fire Solutions/Silent Knight.

7. Honeywell Security & Fire Solutions/Vista.

8. Mircom Technologies, Ltd.

9. Potter Electric Signal Company.

10. Siemens Building Technologies, Inc.

11. Simplex, a brand of Johnson Controls.

12. Provide initiating devices and notification appliances made by the same manufacturer.

2.2 FIRE ALARM SYSTEM

A. Fire Alarm System: Provide modifications and extensions to the existing automatic fire detection and alarm system:

1. Provide all components necessary, regardless of whether shown in Contract Documents or not.

2. Protected Premises: Entire building shown on drawings.

3. Comply with the following; where requirements conflict, order of precedence of requirements is as listed:

a. ADA Standards.

b. The requirements of the State Fire Marshal.

c. The requirements of the local authority having jurisdiction .

d. Applicable local codes.

e. Contract Documents (drawings and specifications).

f. NFPA 101.

g. NFPA 72; where the word "should" is used consider that provision mandatory;

where conflicts between requirements require deviation from NFPA 72, identify deviations clearly on design documents.

4. Evacuation Alarm: Multiple smoke zones; allow for evacuation notification of any individual zone or combination of zones, in addition to general evacuation of entire premises.

5. Voice Notification: Provide emergency voice/alarm communications with multichannel capability; digital.

6. General Evacuation Zones: Each smoke zone is considered a general evacuation zone unless otherwise indicated, with alarm notification in all zones on the same floor, on the floor above, and the floor below.

7. Program notification zones and voice messages as directed by Owner.

8. Hearing Impaired Occupants: Provide visible notification devices in all public areas and in dwelling units.

9. Fire Command Center: Location indicated on drawings.

10. Fire Alarm Control Unit: New, located at fire command center.

February 21, 2025 QE Project # 42137280

28 4600 Fire Detection and Alarm - 6

11. Two-Way Telephone: Provide two-way telephone service for the use of the fire service and others; provide jacks and two portable handsets.

12. Guard's Tour: Provide guard's tour supervisory service in accordance with NFPA 601.

13. Combined Systems: Do not combine fire alarm system with other non-fire systems.

B. Supervising Stations and Fire Department Connections:

1. Public Fire Department Notification: By on-premises supervising station.

2. On-Premises Supervising Station: Existing proprietary station operated by Owner.

3. Means of Transmission to On-Premises Supervising Station: Directly connected noncoded system.

4. Means of Transmission to Remote Supervising Station: Digital alarm communicator transmitter (DACT), 2 telephone lines.

C. Circuits:

1. Initiating Device Circuits (IDC): Class B, Style A.

2. Signaling Line Circuits (SLC) Within Single Building: Class B, Style 0.5.

3. Signaling Line Circuits (SLC) Between Buildings: Class A, Style 2.

4. Notification Appliance Circuits (NAC): Class B, Style W.

D. Spare Capacity:

1. Initiating Device Circuits: Minimum 25 percent spare capacity.

2. Notification Appliance Circuits: Minimum 25 percent spare capacity.

3. Speaker Amplifiers: Minimum 25 percent spare capacity.

4. Fire Alarm Control Units: Capable of handling all circuits utilized to capacity without requiring additional components other than plug-in control modules.

E. Power Sources:

1. Primary: Dedicated branch circuits of the facility power distribution system.

2. Secondary: Storage batteries.

3. Capacity: Sufficient to operate entire system for period specified by NFPA 72.

4. Each Computer System: Provide uninterruptible power supply (UPS).

2.3 EXISTING COMPONENTS

A. Existing Fire Alarm System: Remove existing components indicated and incorporate remaining components into new system, under warranty as if they were new; do not take existing portions of system out of service until new portions are fully operational, tested, and connected to existing system.

B. On-Premises Supervising Station: Include as part of this work all modifications necessary to existing supervising station to accommodate new fire alarm work.

C. Clearly label components that are "Not In Service."

D. Remove unused existing components and materials from site and dispose of properly.

2.4 FIRE SAFETY SYSTEMS INTERFACES

A. Supervision: Provide supervisory signals in accordance with NFPA 72 for the following:

1. Sprinkler water control valves.

2. Dry-pipe sprinkler system pressure.

3. Dry-pipe sprinkler valve room low temperature.

4. Sprinkler water storage tank low level.

5. Sprinkler water storage tank low temperature.

February 21, 2025 QE Project # 42137280

28 4600 Fire Detection and Alarm - 7

B. Alarm: Provide alarm initiation in accordance with NFPA 72 for the following:

1. Sprinkler water flow.

2. Total flooding suppression system activation.

3. Kitchen hood suppression activation; also disconnect fuel source from cooking equipment.

4. Generator room heat detector.

5. Duct smoke detectors.

C. HVAC:

1. Duct Smoke Detectors: Close dampers indicated; shut down air handlers indicated.

2.5 COMPONENTS

A. General:

1. Provide flush mounted units where installed in finish areas; in unfinished areas, surface mounted units are acceptable.

2. Provide legible, permanent labels for each control device, using identification used in operation and maintenance data.

B. Fire Alarm Control Units: Analog, addressable type; listed, classified, and labeled as suitable for the purpose intended.

C. Addressable Fire Alarm Control Unit:Analog, Addressable Type with Integrated Voice Emergency Evacuation Panel.

1. System Capacity: 4,064 addresses; six notification appliance circuits (NACs), expandable to 192; four input/output (I/O) circuits; 1,500 software zones.

2. Voice Integration:

a. Support two hours of message storage; internal library of predefined messages and tones; 255 customizable audio patterns; text-to-speech custom text translation.

b. Provide supervised low-level auxiliary input to interface with external audio sources and support background music applications.

c. Provide eight programmable push buttons for speaker and emergency communication system (ECS) zone assignment, expandable to 104 pushbuttons.

d. Support connection of up to 31 single-channel amplifiers (SCA) or dual-channel amplifiers (DCA), 30 Model LOC-1000 local operator consoles, and one Model FFT-1000 firefighter telephone system supporting 24 phone circuits, expandable to 96.

3. Features: Strobe synchronization; dedicated alarm, supervisory and trouble relays; 4,000 event history buffer; built-in IP communicator; Ethernet port for programming and network connectivity; e-mail system status, reports and event information.

D. Remote Graphic Annunciator Panel: Mounted in aluminum frame with nonglare, minimum 3/16 inch thick, clear acrylic cover over graphic representation of facility. Detector locations must be represented by red LED lamps. Normal system operation must be indicated by lighted, green LED. Trouble and supervisory alarms must be represented by amber LED.

1. Comply with UL 864.

2. Operating voltage must be 24 V(dc) provided by local 24 V power supply provided with annunciator.

3. Include built-in voltage regulation, reverse polarity protection, RS 232/422 serial communications, and lamp test switch.

4. Surface mounted in NEMA 250, Type 1 cabinet, with key lock and no exposed screws or hinges.

February 21, 2025 QE Project # 42137280

28 4600 Fire Detection and Alarm - 8

5. Graphic representation of facility must be CAD drawing and each detector must be represented by LED in its actual location. CAD drawing must be at1:96 scale or larger.

6. LED representing detector must flash two times per second while detector is in alarm.

E. Addressable Modules:

1. Provide addressable modules suitable for connection to fire alarm control unit signaling line circuits.

2. Unless otherwise indicated, use addressable modules only in clean, dry, indoor, nonhazardous locations.

3. Monitor Modules: Unless devices are explicitly permitted to be connected together as zone, provide separate addressable monitor module for each conventional dry-contact input device in order to be individually identifiable by addressable fire alarm control unit.

4. Control Modules: Provide as indicated or as required for selective control of notification appliances.

5. Releasing Control Modules: Provide as indicated or as required for control of listed solenoids in releasing applications.

6. Relay Modules: Provide as indicated or as required to perform necessary functions via dry-contact interface. Where load exceeds module contact rating, provide accessory power isolation relays suitable for load as required.

7. Signaling Line Circuit (SLC) Isolating Modules: Provide as indicated or as required to automatically isolate short circuits on connected sections of SLC loops and allow other sections to continue to function normally. Provide automatic reset upon correction of short circuit.

F. Initiating Devices:

1. Addressable Systems:

a. Addressable Devices: Individually identifiable by addressable fire alarm control unit.

b. Provide suitable addressable interface modules as as required for connection to conventional (non-addressable) devices and other components that provide a dry closure output.

2. Manual Pull Stations: .

a. Provide 1 extra.

3. Key Operated Pull Stations: .

a. Provide 1 extra.

4. Smoke Detectors: .

a. Provide 1 extra.

5. Duct Smoke Detectors: .

a. Provide 1 extra.

6. Heat Detectors: .

a. Provide 1 extra.

G. Notification Appliances:

1. Speakers: .

a. Provide 1 extra.

2. Strobes: .

a. Provide 1 extra.

H. Circuit Conductors: Copper or optical fiber; provide 200 feet extra; color code and label.

I. Surge Protection: In accordance with IEEE C62.41.2 category B combination waveform and NFPA 70; except for optical fiber conductors.

1. Equipment Connected to Alternating Current Circuits: Maximum let through voltage of

350 V(ac), line-to-neutral, and 350 V(ac), line-to-line; do not use fuses.

February 21, 2025 QE Project # 42137280

28 4600 Fire Detection and Alarm - 9

2. Initiating Device Circuits, Notification Appliance Circuits, and Communications Circuits:

Provide surge protection at each point where circuit exits or enters a building; rated to protect applicable equipment; for 24 V(dc) maximum dc clamping voltage of 36 V(dc), line-to-ground, and 72 V(dc), line-to-line.

3. Signaling Line Circuits: Provide surge protection at each point where circuit exits or enters a building, rated to protect applicable equipment.

J. Locks and Keys: Deliver keys to Owner.

1. Provide the same standard lock and key for each key operated switch and lockable panel and cabinet; provide 5 keys of each type

K. Instruction Charts: Printed instruction chart for operators, showing steps to be taken when a signal is received (normal, alarm, supervisory, and trouble); easily readable from normal operator's station.

1. Frame: Stainless steel or aluminum with polycarbonate or glass cover.

2. Provide one for each control unit where operations are to be performed.

3. Obtain approval of Owner prior to mounting; mount in location acceptable to Owner.

4. Provide extra copy with operation and maintenance data submittal.

L. Storage Cabinet for Spare Parts and Tools: Steel with baked enamel finish, size appropriate to quantity of parts and tools.

1. Padlock eye and hasp for lock furnished by Owner.

2. Locate as directed by Owner.

PART 3 EXECUTION

3.1 INSTALLATION

A. Install in accordance with applicable codes, NFPA 72, NFPA 70, and Contract Documents.

B. Conceal all wiring, conduit, boxes, and supports where installed in finished areas.

C. Obtain Owner's approval of locations of devices, before installation.

D. Install instruction cards and labels.

3.2 INSPECTION AND TESTING FOR COMPLETION

A. Notify Owner 7 days prior to beginning completion inspections and tests.

B. Notify authorities having jurisdiction and comply with their…

This is the start of the file's text. The full file is on GovTribe.