Attachment 4D Drawings 12KV OH-UG-4.pdf

PDF 9 MB Posted

Attached to
12KV Overhead to Underground Powerline Replacement At DDJC Federal contract opportunity
Solicitation number
SP330023B0001
Issued by
Defense Logistics Agency Distribution

About this file

This solicitation is for a 12kV Overhead to Underground Powerline Replacement project at the Defense Distribution Depot in Tracy, California. The scope of work includes demolishing existing overhead 12kV power lines and poles, and installing new underground conduits, ductbanks, manholes, lighting poles, transformers and other equipment to provide a fully functioning underground power distribution system. The northern segment currently runs along First Street, while the southern segment extends from D Street along the south end of the facility up to 5th Street. The Defense Logistics Agency Distribution is the contracting agency. Offerors should provide pricing to complete the full scope of work, including removal of overhead infrastructure and installation of the new underground system. The anticipated award date is not specified.

View the file

Other files for this federal contract opportunity

Other files attached to 12KV Overhead to Underground Powerline Replacement At DDJC, newest first.
File Type Posted
Bid Abstract signed 23B0001.pdf PDF
SECTION I - IFB - 12kV PL Revised as of A4.pdf PDF
SP330023B00010004.pdf PDF
12KV OH to UG Site Visit Roster.pdf PDF
SP330023B00010003.pdf PDF
Attachment 3 DDJC Tracy_12 kV OH to UG Specification_J7 Rev2.0.pdf PDF
SP330023B00010002.pdf PDF
SP330023B00010001 change to Site Visit Date .pdf PDF
Attachment 1 23B00010001 Revised SECTION L -IFB - 12kV PL.pdf PDF
Attachment 7 SF25A-Payment Bond AUG16.pdf PDF
Attachment 4E Drawings 12KV OH-UG-5.pdf PDF
Attachment 1 Applicable Wage General Decision Number CA20230018 14APR23.pdf PDF
Attachment 4C Drawings 12KV OH-UG-3.pdf PDF
Attachment 4A Drawings 12KV OH-UG-1.pdf PDF
Attachment 9 Visitor-Contractor Pre_Enrollment.xlsx XLSX spreadsheet
Attachment 8 SF24-Bid Bond AUG16.pdf PDF
Attachment 5 Submittal Register 12KV OH-UG.pdf PDF
Attachment 4F Drawings 12KV OH-UG-6.pdf PDF
Attachment 4B Drawings 12KV OH-UG-2.pdf PDF
Attachment 2 SOW-DDJC Tracy_12 kV OH to UG Specification_J7.pdf PDF
SP330023B0001.pdf PDF
Attachment 6 SF25-Performance Bond AUG16.pdf PDF
Attachment 3 DDJC Tracy_12 kV OH to UG Specification_J7 Rev1.0.pdf PDF
Show all 23

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W/34

W/34A

W/35

W/36

HANDHOLE

W/35A

E

GUARDSHACK

W/34

W/34A

W/35

W/36

W/37

W/38

W/39

W/40

W/41

W/42

W/43

W/44

W/45

W/46

EW/2

EW/3

EW/4

EW/5

EW/6

EW/7

EW/8

EW/9

E

E5

HANDHOLE

E

W/35A

E

GUARDSHACK

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SP

EC

N O

D

ES

IG

N

F

IL

E N

O

TRACY OH BURIAL_ELECTRICAL DEMO SHEETS 6_2_2021.dwg RTA

D D

JC

T

R

AC

Y, C

A

KV

O

VE

R

H

EA

D T

O U

N D

ER

G

R O

U N

D P

O W

ER

L

IN

E

R

EP

LA

C

EM

EN

T

PN

IN

-H

O U

SE

D

ES

IG

N

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

FE

BR

U

AR

Y

W

8-

XX

-X

-X

XX

X

W

8-

XX

-X

-X

XX

X

0-

-0

AN

SI

D

ED105

SI

TE

P

LA

N D

EM

O

ST

AT

IO

N

3+

T

O

0+

O

PT

IO

N

B

ID

R .L

EO

N

R .L

EO

N

D .C

AR

U

LL

I

A.

PA

SC

U

A, P

E

N

GENERAL NOTES:

1. FIELD VERIFY EXISTING CONDITIONS.

2. DEMOLISH ALL EQUIPMENT ON POLES.

3. REFER TO SHEET E-001 FOR LEGEND AND ABBREVIATIONS.

4. CHECK PHASE ROTATION BEFORE AND AFTER SWITCHING OH 12KV TO UNDERGROUND

CABLE.

5. CLIN 3 OPTION: THIS OPTION SHALL INCLUDE THE WORK FROM POLE W/34 TO POLE W/36.

A,B

HA,B

KEY NOTES:

1. DEMOLISH SWITCH ON POLE W/35A.

2. DEMOLISH CONDUITS/DUCTBANKS UP TO EXISTING MANHOLE.

3. PULL BACK CONDUCTORS TO MANHOLE SO THAT IT CAN BE REUSED.

4. REMOVE ALL DATA AND POWER CABLES ON W/34 AND ALL WEATHER HEADS, CONDUITS

OUTSIDE AND INSIDE BUILDING 110 AND GUARD SHACK UP TO THE EXISTING POWER

PANEL.

F

G

ED105

F

H

AutoCAD SHX Text

( IN FEET )

AutoCAD SHX Text

GRAPHIC SCALE

AutoCAD SHX Text

AutoCAD SHX Text

( IN FEET )

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1 inch = 20 ft.

AutoCAD SHX Text

MATCH TO SHEET

AutoCAD SHX Text

ED106

W/37

W/38

W/34

W/34A

W/35

W/36

W/37

W/38

W/39

W/40

W/41

W/42

W/43

W/44

W/45

W/46

EW/2

EW/3

EW/4

EW/5

EW/6

EW/7

EW/8

EW/9

E

E5

HANDHOLE

E

W/35A

E

GUARDSHACK

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SP

EC

N O

D

ES

IG

N

F

IL

E N

O

TRACY OH BURIAL_ELECTRICAL DEMO SHEETS 6_2_2021.dwg RTA

D D

JC

T

R

AC

Y, C

A

KV

O

VE

R

H

EA

D T

O U

N D

ER

G

R O

U N

D P

O W

ER

L

IN

E

R

EP

LA

C

EM

EN

T

PN

IN

-H

O U

SE

D

ES

IG

N

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

FE

BR

U

AR

Y

W

8-

XX

-X

-X

XX

X

W

8-

XX

-X

-X

XX

X

0-

-0

AN

SI

D

ED106

SI

TE

P

LA

N D

EM

O

ST

AT

IO

N

0+

T

O

6+

O

PT

IO

N

B

ID

R .L

EO

N

R .L

EO

N

D .C

AR

U

LL

I

A.

PA

SC

U

A, P

E

N

GENERAL NOTES:

1. FIELD VERIFY EXISTING CONDITIONS.

2. DEMOLISH ALL EQUIPMENT ON POLES.

3. REFER TO SHEET E-001 FOR LEGEND AND ABBREVIATIONS.

4. CHECK PHASE ROTATION BEFORE AND AFTER SWITCHING OH 12KV TO UNDERGROUND

CABLE.

5. CLIN 4 OPTION: THIS OPTION SHALL INCLUDE THE WORK FROM POLE W/36 TO POLE W/41.

KEY NOTES:

1. REMOVE CONDUCTORS FROM EXISTING RISER TO EXISTING TRANSFORMER.

HA,B

F

ED106

AutoCAD SHX Text

( IN FEET )

AutoCAD SHX Text

GRAPHIC SCALE

AutoCAD SHX Text

AutoCAD SHX Text

( IN FEET )

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1 inch = 20 ft.

AutoCAD SHX Text

MATCH TO SHEET

AutoCAD SHX Text

ED105

AutoCAD SHX Text

MATCH TO SHEET

ED107

W/39

W/40

W/34

W/34A

W/35

W/36

W/37

W/38

W/39

W/40

W/41

W/42

W/43

W/44

W/45

W/46

EW/2

EW/3

EW/4

EW/5

EW/6

EW/7

EW/8

EW/9

E

E5

HANDHOLE

E

W/35A

E

GUARDSHACK

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SP

EC

N O

D

ES

IG

N

F

IL

E N

O

TRACY OH BURIAL_ELECTRICAL DEMO SHEETS 6_2_2021.dwg RTA

D D

JC

T

R

AC

Y, C

A

KV

O

VE

R

H

EA

D T

O U

N D

ER

G

R O

U N

D P

O W

ER

L

IN

E

R

EP

LA

C

EM

EN

T

PN

IN

-H

O U

SE

D

ES

IG

N

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

FE

BR

U

AR

Y

W

8-

XX

-X

-X

XX

X

W

8-

XX

-X

-X

XX

X

0-

-0

AN

SI

D

ED107

SI

TE

P

LA

N D

EM

O

ST

AT

IO

N

6+

T

O

2+

O

PT

IO

N

B

ID

R .L

EO

N

R .L

EO

N

D .C

AR

U

LL

I

A.

PA

SC

U

A, P

E

N

GENERAL NOTES:

1. FIELD VERIFY EXISTING CONDITIONS.

2. DEMOLISH ALL EQUIPMENT ON POLES.

3. REFER TO SHEET E-001 FOR LEGEND AND ABBREVIATIONS.

4. CHECK PHASE ROTATION BEFORE AND AFTER SWITCHING OH 12KV TO UNDERGROUND

CABLE.

5. CLIN 4 OPTION THIS OPTION SHALL INCLUDE THE WORK FROM POLE W/36 TO POLE

W/41.

KEY NOTES:

1. REMOVE CONDUCTORS FROM EXISTING RISER TO EXISTING TRANSFORMER.

HA,B

F

ED107

AutoCAD SHX Text

( IN FEET )

AutoCAD SHX Text

GRAPHIC SCALE

AutoCAD SHX Text

AutoCAD SHX Text

( IN FEET )

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1 inch = 20 ft.

AutoCAD SHX Text

MATCH TO SHEET

AutoCAD SHX Text

ED106

AutoCAD SHX Text

MATCH TO SHEET

ED108

W/41

W/42

W/34

W/34A

W/35

W/36

W/37

W/38

W/39

W/40

W/41

W/42

W/43

W/44

W/45

W/46

EW/2

EW/3

EW/4

EW/5

EW/6

EW/7

EW/8

EW/9

E

E5

HANDHOLE

E

W/35A

E

GUARDSHACK

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SP

EC

N O

D

ES

IG

N

F

IL

E N

O

TRACY OH BURIAL_ELECTRICAL DEMO SHEETS 6_2_2021.dwg RTA

D D

JC

T

R

AC

Y, C

A

KV

O

VE

R

H

EA

D T

O U

N D

ER

G

R O

U N

D P

O W

ER

L

IN

E

R

EP

LA

C

EM

EN

T

PN

IN

-H

O U

SE

D

ES

IG

N

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

FE

BR

U

AR

Y

W

8-

XX

-X

-X

XX

X

W

8-

XX

-X

-X

XX

X

0-

-0

AN

SI

D

ED108

SI

TE

P

LA

N D

EM

O

ST

AT

IO

N

2+

T

O

8+

O

PT

IO

N

B

ID

R .L

EO

N

R .L

EO

N

D .C

AR

U

LL

I

A.

PA

SC

U

A, P

E

N

GENERAL NOTES:

1. FIELD VERIFY EXISTING CONDITIONS.

2. DEMOLISH ALL EQUIPMENT ON POLES.

3. REFER TO SHEET E-001 FOR LEGEND AND ABBREVIATIONS.

4. CHECK PHASE ROTATION BEFORE AND AFTER SWITCHING OH 12KV TO UNDERGROUND CABLE.

5. CLIN 4 OPTION: THIS OPTION SHALL INCLUDE THE WORK FROM POLE W/36 TO POLE W/41.

6. CLIN 5 OPTION: THIS OPTION SHALL INCLUDE THE WORK FROM POLE W/41 TO POLE W/47 AND TO POLE EW/2.

KEY NOTES:

1. REMOVE CONDUCTORS AND CONDUIT FROM EXISTING RISER (POLE W/41) TO

EXISTING RISER (POLE W/42).

2. DEMOLISH SWITCH ON POLE W/41.

A,B

A

A,B E

ED108

AutoCAD SHX Text

( IN FEET )

AutoCAD SHX Text

GRAPHIC SCALE

AutoCAD SHX Text

AutoCAD SHX Text

( IN FEET )

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1 inch = 20 ft.

AutoCAD SHX Text

MATCH TO SHEET

AutoCAD SHX Text

ED107

AutoCAD SHX Text

MATCH TO SHEET

ED109

W/43

W/44

W/45

W/46

EW/2

W/34

W/34A

W/35

W/36

W/37

W/38

W/39

W/40

W/41

W/42

W/43

W/44

W/45

W/46

EW/2

EW/3

EW/4

EW/5

EW/6

EW/7

EW/8

EW/9

E

E5

HANDHOLE

E

W/35A

E

GUARDSHACK

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SP

EC

N O

D

ES

IG

N

F

IL

E N

O

TRACY OH BURIAL_ELECTRICAL DEMO SHEETS 6_2_2021.dwg RTA

D D

JC

T

R

AC

Y, C

A

KV

O

VE

R

H

EA

D T

O U

N D

ER

G

R O

U N

D P

O W

ER

L

IN

E

R

EP

LA

C

EM

EN

T

PN

IN

-H

O U

SE

D

ES

IG

N

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

FE

BR

U

AR

Y

W

8-

XX

-X

-X

XX

X

W

8-

XX

-X

-X

XX

X

0-

-0

AN

SI

D

ED109

SI

TE

P

LA

N D

EM

O

ST

AT

IO

N

8+

T

O

3+

O

PT

IO

N

B

ID

R .L

EO

N

R .L

EO

N

D .C

AR

U

LL

I

A.

PA

SC

U

A, P

E

N

GENERAL NOTES:

1. FIELD VERIFY EXISTING CONDITIONS.

2. DEMOLISH ALL EQUIPMENT ON POLES.

3. REFER TO SHEET E-001 FOR LEGEND AND ABBREVIATIONS.

4. CHECK PHASE ROTATION BEFORE AND AFTER SWITCHING OH 12KV TO UNDERGROUND

CABLE.

5. CLIN 5 OPTION: THIS OPTION SHALL INCLUDE THE WORK FROM POLE W/41 TO POLE W/47

AND TO POLE EW/2.

KEY NOTES:

1. REMOVE CONDUCTORS, CAP CONDUITS AND ABANDON IN PLACE.

A,B

A,B

A

F

ED109

AutoCAD SHX Text

( IN FEET )

AutoCAD SHX Text

GRAPHIC SCALE

AutoCAD SHX Text

AutoCAD SHX Text

( IN FEET )

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1 inch = 20 ft.

AutoCAD SHX Text

MATCH TO SHEET

AutoCAD SHX Text

ED108

AutoCAD SHX Text

MATCH TO SHEET

ED110

PI: 11+60.84

W/18A

W/18

W/17

N24

1S T

ST

R

EE

T

C E

H H

H

M H

-1

H H

-1 H

H -2

H H

-3

PS

S1

PI: 11+60.84

PI: 13+07.02

PI: 14+77.35

PI: 16+51.15

PI: 17+88.53

PI: 19+44.34

PI

: 2

2+

.4

W/18A

W/18

W/17

W/16

W/15

W/14

W/13

W/12 A/1 A/2

A/3 A/4

N24

N37

N39

N50

1S T

ST

R

EE

T

1S T

ST

R

EE

T

1S T

ST

R

EE

T

A STREET

ST

AT

IO

N

S

TR

EE

T

C C

C

C

E E

E E

LP

E

A/1

H H

H E

H H

H H

H H

H H

H H

H

H

E

LP

3)

LP

1)

M H

-1 M

H -2

M H

-3

M H

-4

M H

-5

M H

-6

H H

-1 H

H -2

H H

-3 H

H -4

H H

-5 H

H -6

H H

-7 H

H -8

H H

-9 H

H -1

H

H -1

1 H H

-1

PS

S1

H

H

H

HH-13

HH-14

HH-15

DL

A

SI

GN

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SP

EC

N O

D

ES

IG

N

F

IL

E N

O

TRACY OH BURIAL_ELECTRICAL SHEETS UPDATED ROUTE For Reliability.dwg RTA

D D

JC

T

R

AC

Y, C

A

KV

O

VE

R

H

EA

D T

O U

N D

ER

G

R O

U N

D P

O W

ER

L

IN

E

R

EP

LA

C

EM

EN

T

PN

IN

-H

O U

SE

D

ES

IG

N

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

FE

BR

U

AR

Y

W

8-

XX

-X

-X

XX

X

W

8-

XX

-X

-X

XX

X

0-

-0

AN

SI

D

E-101

SI

TE

P

LA

N

ST

AT

IO

N

0+

T O

2+

BA

SE

B

ID

R .L

EO

N

R .L

EO

N

D .C

AR

U

LL

I

A.

PA

SC

U

A, P

E

N

GENERAL NOTES:

1. THE PRIMARY PHASE CONDUCTORS SHALL BE SINGLE CONDUCTOR COPPER, 15KV, 133

PERCENT INSULATION, TYPE MV105, WITH A SEMI CONDUCTING SCREEN, EPR INSULATION,

AND COPPER TAPE SHIELDING.

2. FIELD VERIFY EXISTING CONDITIONS.

3. POLE NUMBERS AND POLES SHALL NO LONGER EXIST AFTER DEMOLITION. POLE NUMBERS

AND POLE LOCATIONS ARE FOR REFERENCE ONLY.

4. REFER TO SHEET E-001 FOR LEGEND AND ABBREVIATIONS.

5. CHECK PHASE ROTATION BEFORE AND AFTER SWITCHING OH 12KV TO UNDERGROUND

CABLE.

KEY NOTES:

1. PROVIDE (3) # 4/0 15KV EPR, COPPER CABLE FOR PRIMARY POWER IN TWO CONDUITS.

PROVIDE DUCTBANK PER DETAIL 6 SHEET E-503.

2. PROVIDE ELECTRICAL MANHOLE PER DETAIL 1 SHEET E-502.

3. PROVIDE NEW LIGHT POLES AND LUMINARIES PER DETAILS 4 AND 5 ON SHEET E-501.

MOUNT NEW LUMINARIES ON LIGHT POLES AT 24 FEET HEIGHT. PROVIDE HANDHOLE PER

DETAIL 3 ON SHEET E-502.

4. PROVIDE A SPLICE IN MANHOLE N24 TO CONTINUE NEW TELECOMMUNICATION TO

BUILDING 100. PROVIDE A WATERPROOF COPPER SPLICE CLOSURE TO SPLICE NEW OSP 200

PAIR COPPER CABLE AND PULL IN EXISTING SPARE CONDUIT INTO EXISTING

COMMUNICATIONS ROOM IN BLDG. 100. PROVIDE A NEW PROTECTED ENTRANCE

TERMINAL, PER TC-I3A, TO TERMINATE THE 200 PAIR COPPER.

5. EXTEND EXISTING CONDUIT AND CONDUCTOR TO NEW MANHOLE MH-1 AND THEN TO PAD

MOUNTED SWITCH S1. NEW (3) # 4/0 15KV EPR, COPPER CABLE FOR PRIMARY POWER.

6. PROVIDE (2) # 4 AND (1) #12 G , COPPER CABLE FOR LIGHTING. PROVIDE LIGHTING DUCTBANK PER DETAIL 4 ON SHEET E-503.

7. PROVIDE 4-WAY 15KV PAD-MOUNTED SWITCH PER DETAIL 2 ON SHEET E-503. FUSE RATING TO BE COORDINATED WITH

DOWNSTREAM LOAD. PROVIDE ENGRAVED LABELS TO DISPLAY INFORMATION INCLUDING SWITCH #, POWER SOURCE FROM AND TO, FEEDING POWER TO BUILDING #. CONTACT PROJECT ENGINEER FOR MORE INFORMATION.

8. PROVIDE DUAL LUMINARE TYPE POLES FROM HH-1 TO HH-14.

9. PROVIDE (3) # 4/0 15KV EPR, COPPER CABLE FOR PRIMARY POWER IN EACH CONDUIT. PROVIDE DUCTBANK PER DETAIL 5

SHEET E-503.

AutoCAD SHX Text

( IN FEET )

AutoCAD SHX Text

GRAPHIC SCALE

AutoCAD SHX Text

AutoCAD SHX Text

( IN FEET )

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1 inch = 20 ft.

AutoCAD SHX Text E-101

AutoCAD SHX Text

MATCH TO SHEET

E-102

File details come from the government source that posted it. Updated .