About this file
This set of construction drawings and related federal contract opportunity provide details for a 12kV overhead to underground powerline replacement project at the Defense Distribution Depot in Tracy, California. The project involves removing existing overhead 12kV power lines, poles, and auxiliary communications equipment, and installing new underground conduits, duct banks, manholes, lighting poles, transformers, and other accessories to provide a complete underground electrical distribution system. Drawings show the location of existing overhead lines and equipment to be demolished, as well as specifications for trenching, conduit installation, and connections to new underground transformers and switches. The solicitation is open for proposals from contractors to complete this work, with the base bid focusing on the segment between two poles and options to complete additional segments. The Defense Logistics Agency Distribution is the contracting agency responsible for this infrastructure upgrade project at their facility.
View the file
Other files for this federal contract opportunity
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SP
EC
N O
D
ES
IG
N
F
IL
E N
O
TRACY OH BURIAL_ELECTRICAL DEMO SHEETS 6_2_2021.dwg RTA
D D
JC
T
R
AC
Y, C
A
KV
O
VE
R
H
EA
D T
O U
N D
ER
G
R O
U N
D P
O W
ER
L
IN
E
R
EP
LA
C
EM
EN
T
PN
IN
-H
O U
SE
D
ES
IG
N
J
S
TR
EE
T
SA
C
R
AM
EN
TO
, C A
SA
C
R
AM
EN
TO
D
IS
TR
IC
T
J
S
TR
EE
T
SA
C
R
AM
EN
TO
, C A
FE
BR
U
AR
Y
W
8-
XX
-X
-X
XX
X
W
8-
XX
-X
-X
XX
X
0-
-0
AN
SI
D
E-001
LE
G
EN
D
A N
D A
BB
R
EV
IA
TI
O
N S
R . L
EO
N
R . L
EO
N
D . C
AR
U
LL
I
A.
P
AS
C
U A, P E
FUSED DISCONNECT/STARTER SWITCH. SIZE FUSES FOR EQUIPMENT BASED ON
MANUFACTURER RECOMMENDATIONS
SURFACE MOUNTED PANELBOARD
POWER WIRING
EXTERIOR SITE
ABBREVIATIONS
NEW POLE MOUNTED LIGHTING FIXTURE
J JUNCTION BOX OR EQUIPMENT BOX, SIZE VARIES
UNFUSED DISCONNECT SWITCH.
WHEN ADJACENT TO MOTOR, COMBINED MOTOR STARTER/DISCONNECT
SINGLE LINE DIAGRAM
A
UTILITY METER
NON FUSED DISCONNECT
BREAKLINE
LUMINAIRE TAG. IF SHOWN, SECOND LINE IS SWITCH LABEL
FOR LUMINAIRE (SEE BELOW). SEE LUMINAIRE SCHEDULE,
SHEET E-501.
CALLOUTS
A-B SWITCH TAG. FIRST LETTER DESIGNATES ROOM/AREA.
SECOND LETTER DESIGNTATES SWITCH SYSTEM IN ROOM.
M
EF-1
MECHANICAL OR PLUMBING EQUIPMENT TAG. SEE HVAC
EQUIPMENT SCHEDULES, SHEET M-601, OR PLUMBING
EQUIPMENT SCHEDULES, SHEET P-601.
(PP-1) - (1) CIRCUIT CALLOUT. FIRST PERENTHESES IS PANEL NAME,
SECOND PERENTHESES IS CIRCUIT NUMBER IN THAT PANEL.
1 KEYNOTE CALLOUT. SEE KEYNOTE LEGEND ON RELEVANT
SHEETS.
ARROW INDICATES HOMERUN OR CONTINUATION OF CIRCUIT.
HOMERUN WILL BE ANNOTATED WITH PANEL/CIRCUIT NUMBER.
DOTTED TICK MARK IS GROUND, LONG TICK MARK IS NEUTRAL,
SHORT TICK MARKS ARE NUMBER OF PHASE CONDUCTORS.(P1)-(1)
GENERAL LINES
DEMOLISHED
NEW
A-101
1 VIEW CALLOUT. TOP IS DETAIL NUMBER OF VIEW,
BOTTOM IS SHEET THAT VIEW APPEARS ON.
MATCHLINE
UNAFFECTED/EXISTING
A AMPERE
AC ABOVE COUNTER
ADA AMERICANS WITH DISABILITIES ACT
AFF ABOVE FINISHED FLOOR
AL ALUMINUM
1/C ONE CONDUCTOR
C CONDUIT
CB CIRCUIT BREAKER
CKT CIRCUIT
CU COPPER
EF EXHAUST FAN
EMT ELECTRICAL METALLIC TUBING
EWC ELECTRIC WATER COOLER
FACP FIRE ALARM CONTROL PANEL
FM FREQUENCY MODULATION
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GFP GROUND FAULT PROTECTION
HACR HEATING AIR CONDITIONING REFRIGERATION
HP HORSEPOWER
HPS HIGH PRESSURE SODIUM
HT HEIGHT
HZ HERTZ
IDS INTRUSION DETECTION SYSTEM
J JUNCTION BOX
KWH KILOWATT HOUR
LCP LIGHTING CONTROL PANEL
MCB MOLDED CASE CIRCUIT BREAKER/MAIN CIRCUIT BREAKER
MH METAL HALIDE
MLO MAIN LUGS ONLY
MTD MOUNTED
NEC NATIONAL ELECTRICAL CODE
NF NON FUSED
NO. NUMBER
OS OCCUPANCY SENSOR
PH PHASE
PIR PASSIVE INFRARED
RGS RIGID GALVANIZED STEEL
RMF RISK MANAGEMENT FRAMEWORK
TTB TELEPHONE TERMINAL BACKBOARD
TV TELEVISION
TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR
UNO UNLESS NOTED OTHERWISE
V VOLT
VA VOLTAMPERE
VVD VARIABLE VOLUME DAMPER
W WATTS
WP WATER PROOF
XFMR TRANSFORMER
LOC LOCAL OPERATING CONSOLE
ACU AUTONOMOUS CONTROL UNIT
MNS MASS NOTIFICATION SYSTEM
NEC NETWORK ENTERPRISE CENTER
CCTV CLOSED CIRCUIT TELEVISION
DT DUAL TECHNOLOGY (OCCUPANCY SENSOR)
U ULTRASONIC
DS DAYLIGHT SENSOR
PV PHOTOVOLTAIC
GND GROUND
LED LIGHT EMITTING DIODE
DVR DIGITAL VIDEO RECORDER
ACS ACCESS CONTROL SYSTEM
NOCT NOMINAL OPREATING CELL TEMPERATURE
MPPT MAXIMUM POWER POINT TRACKING
GENERAL NOTES
1. NOT ALL SYMBOLS SHOWN MAY BE USED IN
THIS DRAWING SET.
2. UNLESS NOTED OTHERWISE, ALL
CONDUCTORS SHALL BE COPPER.
3. IF CONTRACTOR INSTALLS MORE THAN 3
CURRENT CARRYING CONDUCTORS IN A
RACEWAY, CONTRACTOR SHALL BE
RESPONSIBLE FOR APPLYING AMPACITY
DERATING FACTORS TO THE CONDUCTORS,
AND RESIZING THE CONDUCTORS AS
NEEDED PER NEC ARTICLE 311.60(D)(4).
4. FIELD VERIFY EXISTING CONDITIONS AND
EQUIPMENT.
5. DESIGN IS BASED ON 15KV, 4/0 EPR, MV-105
COPPER CABLE AMPACITY. IF OTHER
CONDUCTOR IS USED IT MUST BE 15KV, 4/0
EPR, MV-105 AND MUST BE CAPABLE OF THE
SAME AMPACITY OR GREATER.
6. SCHEDULE POWER OUTAGES WITH TRACY
DPW AND THE COR, AS REQUIRED, TO
TRANSITION THE OVERHEAD ELECTRICAL
SYSTEM TO NEW UNDERGROUND
ELECTRICAL SYSTEM AND TO LIMIT
DURATION OF POWER OUTAGES TO
PERIODS ACCEPTABLE TO DPW. IF DEEMED
NECESSARY BY DPW, PROVIDE PORTABLE
GENERATOR POWER FOR FACILITIES THAT
CANNOT AFFORD TO BE WITHOUT POWER
DURING SCHEDULED OUTAGES.
7. VERIFY AND DOCUMENT, IN THE PRESENCE OF
THE COR, THE EXISTING MEDIUM VOLTAGE
CABLE PHASE SEQUENCE ON OVERHEAD POWER
POLE CONDUCTORS WHERE NEW OVERHEAD
TO UNDERGROUND CONVERSION RISER POLES
WILL BE INSTALLED, AND AT PADMOUNTED
SWITCHGEAR AND PRIMARIES OF
PADMOUNTED TRANSFORMERS TO ENSURE THE
SAME SEQUENCE IS MAINTAINED AFTER
CONVERSION TO AN UNDERGROUND MEDIUM
VOLTAGE SYSTEM. VERIFY PHASE ROTATION AT
MAIN DISCONNECTS OF FACILITIES, AS
DIRECTED BY COR, TO ENSURE PHASE ROTATION
IS MAINTAINED.
8. PROVIDE FUSE/CIRCUIT BREAKER SIZES ON
PAD-MOUNTED SWITCHES, TRANSFORMERS,
PANELBOARDS AND RISERS AS
RECOMMENDED PER THE COORDINATION
STUDY AND FAULT SHORT CIRCUIT
ANALYSIS AS REQUIRED BY SPEC 26 28 01.00
10.
9. PROVIDE ENOUGH SLACK FOR
CONDUCTORS TO PERFORM ONE RUN
ALONG THE LONG SIDE OF THE MANHOLE IN
EACH MANHOLE AT A MINIMUM.
10. CONTRACT SHALL INCLUDE BASE BID AND
OPTIONS.
10.1. BASE BID: BASE BID SHALL INCLUDE
WORK FROM POLE W/18A TO POLE A/4.
10.2. OPTION 1: THIS OPTION SHALL INCLUDE
THE WORK FROM POLE W/34 TO POLE
W/36.
10.3. OPTION 2: THIS OPTION SHALL INCLUDE
THE WORK FROM POLE W/36 TO POLE
W/41.
10.4. OPTION 3: THIS OPTION SHALL INCLUDE
THE WORK FROM POLE W/41 TO POLE
W/47 AND TO POLE EW/2.
10.5. OPTION 4: THIS OPTION SHALL INCLUDE
THE WORK FROM POLE EW/2 TO POLE
EW/9.
NEW PAD MOUNTED TRANSFORMER
ELECTRICAL MANHOLE
COMMUNICATIONS MANHOLE
EXISTING ITEMS TO BE REMOVED
OVERHEAD PRIMARY ELECTRICAL LINE.
OVERHEAD COMMUNICATION LINE
E
HANDHOLE. "E" OR "C" DENOTES ELEC OR COMM
E (OH)
C (OH)
E (UG)
ES
C (UG)
UNDERGROUND PRIMARY
UNDERGROUND SECONDARY
UNDERGROUND COMMUNICATIONS
H
E
C
PULL BOX. "E" OR "C" DENOTES ELEC OR COMMPB
C
E
SM SINGLE MODE
REFERENCES
ALL FEATURES OF WORK SHALL MEET THE
FOLLOWING CRITERIA, WHERE APPLICABLE. THIS
LIST IS NOT ALL-INCLUSIVE. SEE SPECIFICATIONS
FOR ADDITIONAL CRITERIA.
NFPA 70, NATIONAL ELECTRICAL CODE (NEC), 2020
NFPA 70E, 2018
NFPA 101, 2018
IEEE C2, 2017
IEEE 1584, 2018
ASHRAE 90.1, 2019
UFC 1-200-02, 2020
UFC 3-501-01, 2019
UFC 3-520-01, 2019
UFC 3-530-01, 2019
UFC 3-550-01, 2019
UFC 3-560-01, 2019
UFC 3-570-01 (CATHODIC PROTECTION), 2019
UFC 4-010-01, 2020
PAD MOUNTED SWITCH
POLE MOUNTED LIGHTING FIXTURE
EXISTING ELECTRICAL LINE DATA
A. (3) 4/0 ACSR, 15KV PRIMARY OVERHEAD.
B. (2) #4, 600V
C. (3) 2/0 AL PRIMARY OVERHEAD
D. 24 MULTIMODE FIBER OPTIC.
E. 900 PAIR COPPER.
F. (3) #2, 600V
G. (6) 350 KCMIL
H. 75 PAIR COPPER.
I. (3) #4/0, 15KV EPR, CU UNDERGROUND CABLE.
POLE WITH RISER
POLE WITH RISER
POLE
POLE
NEW PAD MOUNTED TRANSFORMER
FUSED DISCONNECT
POLE TOP TRANSFORMER
EXISTING PAD MOUNTED TRANSFORMER
EXISTING PAD MOUNTED TRANSFORMER
POLE TOP DISCONNECT
SPLICE
EXISTING OVERHEAD PRIMARY ELECTRICAL LINE.E
TYP TYPICAL
POLE MOUNTED DUAL LIGHTING FIXTURE
A
AutoCAD SHX Text
SPLICE
W/18A
W/18
W/17
N24
1S T
ST
R
EE
T
C
W/18A
W/18
W/17
W/16
W/15
W/14
W/13
W/12 A/1 A/2
A/3 A/4
N24
N37
N39
N50
1S T
ST
R
EE
T
1S T
ST
R
EE
T
1S T
ST
R
EE
T
A STREET
ST
AT
IO
N
S
TR
EE
T
C C
C
C H
H
H
E
DL
A
SI
GN
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SP
EC
N O
D
ES
IG
N
F
IL
E N
O
TRACY OH BURIAL_ELECTRICAL DEMO SHEETS 6_2_2021.dwg RTA
D D
JC
T
R
AC
Y, C
A
KV
O
VE
R
H
EA
D T
O U
N D
ER
G
R O
U N
D P
O W
ER
L
IN
E
R
EP
LA
C
EM
EN
T
PN
IN
-H
O U
SE
D
ES
IG
N
J
S
TR
EE
T
SA
C
R
AM
EN
TO
, C A
SA
C
R
AM
EN
TO
D
IS
TR
IC
T
J
S
TR
EE
T
SA
C
R
AM
EN
TO
, C A
FE
BR
U
AR
Y
W
8-
XX
-X
-X
XX
X
W
8-
XX
-X
-X
XX
X
0-
-0
AN
SI
D
ED101
SI
TE
P
LA
N D
EM
O
ST
AT
IO
N
0+
T
O
2+
BA
SE
B
ID
R . L
EO
N
R . L
EO
N
D . C
AR
U
LL
I
A.
P
AS
C
U A, P E
N
GENERAL NOTES:
1. FIELD VERIFY EXISTING CONDITIONS.
2. DEMOLISH ALL OVERHEAD LINES AND POLES STARTING FROM POLE W/18A AND ENDING
AT POLE A/3.
3. DEMOLISH ALL EQUIPMENT SUPPORTED ON POLES. COORDINATE WITH DPW IF THEY WISH
TO SALVAGE ANY EQUIPMENT.
4. REFER TO SHEET E-001 FOR LEGEND AND ABBREVIATIONS.
5. CHECK PHASE ROTATION BEFORE AND AFTER SWITCHING OH 12KV TO UNDERGROUND
CABLE.
KEY NOTES:
1. REMOVE CONDUCTORS FROM EXISTING RISERS.
2. REMOVE TELECOMMUNICATIONS, CAP DUCTS AND ABANDON DUCTS FROM RISER W/18
TO MANHOLE N24.
3. DEMOLISH SWITCH ON POLE W/18.
4. EXISTING UNDERGROUND ELECTRICAL FROM ACP PROJECT TERMINATES AT W/18 . PULL
BACK CONDUCTOR TO MANHOLES.
5. CUT AND CAP CONDUITS TO EXTEND THEM TO NEW MANHOLE "MH-1" IN NEW WORK,
REFER TO SHEET E-101 FOR REFERENCE.
A,B
D,E
E
A,B
ED101
AutoCAD SHX Text
( IN FEET )
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text
AutoCAD SHX Text
( IN FEET )
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1 inch = 20 ft.
AutoCAD SHX Text
MATCH TO SHEET
ED102
W/16
W/15
N37
1S T
ST
R
EE
T
C
W/18A
W/18
W/17
W/16
W/15
W/14
W/13
W/12 A/1 A/2
A/3 A/4
N24
N37
N39
N50
1S T
ST
R
EE
T
1S T
ST
R
EE
T
1S T
ST
R
EE
T
A STREET
ST
AT
IO
N
S
TR
EE
T
C C
C
C H
H
H
E
DL
A
SI
GN
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SP
EC
N O
D
ES
IG
N
F
IL
E N
O
TRACY OH BURIAL_ELECTRICAL DEMO SHEETS 6_2_2021.dwg RTA
D D
JC
T
R
AC
Y, C
A
KV
O
VE
R
H
EA
D T
O U
N D
ER
G
R O
U N
D P
O W
ER
L
IN
E
R
EP
LA
C
EM
EN
T
PN
IN
-H
O U
SE
D
ES
IG
N
J
S
TR
EE
T
SA
C
R
AM
EN
TO
, C A
SA
C
R
AM
EN
TO
D
IS
TR
IC
T
J
S
TR
EE
T
SA
C
R
AM
EN
TO
, C A
FE
BR
U
AR
Y
W
8-
XX
-X
-X
XX
X
W
8-
XX
-X
-X
XX
X
0-
-0
AN
SI
D
ED102
SI
TE
P
LA
N D
EM
O
ST
AT
IO
N
2+
T
O
6+
BA
SE
B
ID
R . L
EO
N
R . L
EO
N
D . C
AR
U
LL
I
A.
P
AS
C
U A, P E
N
GENERAL NOTES:
1. FIELD VERIFY EXISTING CONDITIONS.
2. DEMOLISH ALL OVERHEAD LINES AND POLES STARTING FROM POLE W/18A AND ENDING
AT POLE A/3.
3. DEMOLISH ALL EQUIPMENT ON POLES.
4. REFER TO SHEET E-001 FOR LEGEND AND ABBREVIATIONS.
5. CHECK PHASE ROTATION BEFORE AND AFTER SWITCHING OH 12KV TO UNDERGROUND
CABLE.
D,EA,B
D,EA,B
ED102
AutoCAD SHX Text
( IN FEET )
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text
AutoCAD SHX Text
( IN FEET )
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1 inch = 20 ft.
AutoCAD SHX Text
MATCH TO SHEET
AutoCAD SHX Text
ED101
AutoCAD SHX Text
MATCH TO SHEET
ED103
W/14
W/13
W/12 A/1
N39
1S T
ST
R
EE
T
C
H
H
W/18A
W/18
W/17
W/16
W/15
W/14
W/13
W/12 A/1 A/2
A/3 A/4
N24
N37
N39
N50
1S T
ST
R
EE
T
1S T
ST
R
EE
T
1S T
ST
R
EE
T
A STREET
ST
AT
IO
N
S
TR
EE
T
C C
C
C H
H
H
E
DL
A
SI
GN
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SP
EC
N O
D
ES
IG
N
F
IL
E N
O
TRACY OH BURIAL_ELECTRICAL DEMO SHEETS 6_2_2021.dwg RTA
D D
JC
T
R
AC
Y, C
A
KV
O
VE
R
H
EA
D T
O U
N D
ER
G
R O
U N
D P
O W
ER
L
IN
E
R
EP
LA
C
EM
EN
T
PN
IN
-H
O U
SE
D
ES
IG
N
J
S
TR
EE
T
SA
C
R
AM
EN
TO
, C A
SA
C
R
AM
EN
TO
D
IS
TR
IC
T
J
S
TR
EE
T
SA
C
R
AM
EN
TO
, C A
FE
BR
U
AR
Y
W
8-
XX
-X
-X
XX
X
W
8-
XX
-X
-X
XX
X
0-
-0
AN
SI
D
ED103
SI
TE
P
LA
N D
EM
O
ST
AT
IO
N
6+
T
O
1+
BA
SE
B
ID
R . L
EO
N
R . L
EO
N
D . C
AR
U
LL
I
A.
P
AS
C
U A, P E
GENERAL NOTES:
1. FIELD VERIFY EXISTING CONDITIONS.
2. DEMOLISH ALL OVERHEAD LINES AND POLES STARTING FROM POLE W/18A AND ENDING
AT POLE A/3.
3. DEMOLISH ALL EQUIPMENT ON POLES.
4. REFER TO SHEET E-001 FOR LEGEND AND ABBREVIATIONS.
5. CHECK PHASE ROTATION BEFORE AND AFTER SWITCHING OH 12KV TO UNDERGROUND
CABLE.
D,EA,B
D,EA,B
KEY NOTES:
1. DEMOLISH SWITCH ON POLE W/13.
2. REMOVE CONDUCTORS FROM EXISTING DUCTS AND HANDHOLES.
3. REMOVE CONDUCTORS FROM EXISTING DUCTS. EXISTING DUCTS ARE TO BE REUSED TO
REFEED POWER TO PANELBOARD AT GATEHOUSE.
B
ED103
N
AutoCAD SHX Text
MATCH TO SHEET
AutoCAD SHX Text
ED102
AutoCAD SHX Text
MATCH TO SHEET
AutoCAD SHX Text
ED104
AutoCAD SHX Text
( IN FEET )
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text
AutoCAD SHX Text
( IN FEET )
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1 inch = 20 ft.
W/12 A/1 A/2
A/3 A/4
A STREET
ST
AT
IO
N
S
TR
EE
T
H H
H
DL
A
SI
GN
W/18A
W/18
W/17
W/16
W/15
W/14
W/13
W/12 A/1 A/2
A/3 A/4
N24
N37
N39
N50
1S T
ST
R
EE
T
1S T
ST
R
EE
T
1S T
ST
R
EE
T
A STREET
ST
AT
IO
N
S
TR
EE
T
C C
C
C H
H
H
E
DL
A
SI
GN
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
SP
EC
N O
D
ES
IG
N
F
IL
E N
O
TRACY OH BURIAL_ELECTRICAL DEMO SHEETS 6_2_2021.dwg RTA
D D
JC
T
R
AC
Y, C
A
KV
O
VE
R
H
EA
D T
O U
N D
ER
G
R O
U N
D P
O W
ER
L
IN
E
R
EP
LA
C
EM
EN
T
PN
IN
-H
O U
SE
D
ES
IG
N
J
S
TR
EE
T
SA
C
R
AM
EN
TO
, C A
SA
C
R
AM
EN
TO
D
IS
TR
IC
T
J
S
TR
EE
T
SA
C
R
AM
EN
TO
, C A
FE
BR
U
AR
Y
W
8-
XX
-X
-X
XX
X
W
8-
XX
-X
-X
XX
X
0-
-0
AN
SI
D
ED104
SI
TE
P
LA
N D
EM
O
ST
AT
IO
N
0+
T
O
5+
BA
SE
B
ID
R . L
EO
N
R . L
EO
N
D . C
AR
U
LL
I
A.
P
AS
C
U A, P E
N
GENERAL NOTES:
1. FIELD VERIFY EXISTING CONDITIONS.
2. DEMOLISH ALL OVERHEAD LINES AND POLES STARTING FROM
POLE W/18A AND ENDING AT POLE A/3.
3. DEMOLISH ALL EQUIPMENT ON POLES.
4. REFER TO SHEET E-001 FOR LEGEND AND ABBREVIATIONS.
5. CHECK PHASE ROTATION BEFORE AND AFTER SWITCHING OH
12KV TO UNDERGROUND CABLE.
D,EC,B
D,EC,B
B
B
KEY NOTES:
1. REMOVE CONDUCTORS FROM EXISTING DUCTS AND
HANDHOLES.
2. REMOVE ALL 4 EXISTING RISERS ON POLE A/4 FEEDING DATA
CABLES FROM POLE A/3 TO MAKE ROOM FOR NEW 12KV
RISER.
3. REMOVE OVERHEAD COMMUNICATIONS CABLE FROM POLE
A/1 UP TO THE COMMUNICATIONS BOX LOCATED INSIDE
GUARDHOUSE.
F
ED104
F F
AutoCAD SHX Text
( IN FEET )
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text
AutoCAD SHX Text
( IN FEET )
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1 inch = 20 ft.
AutoCAD SHX Text
MATCH TO SHEET
ED103
File details come from the government source that posted it. Updated .