This document is an architectural drawing set for elevator standards established by the Department of Veterans Affairs. The drawings illustrate floor plans and wall elevations for both passenger and service elevators, detailing the specifications and layout requirements for elevator installations within VA facilities.

The passenger elevator specifications include floor call buttons (numbered 1-5), car control panels with a 42-inch minimum width, emergency buttons with a 48-inch maximum height clearance, and stainless steel (SS-1) and high-pressure laminate (HPL-1) wall finishes. The service elevator configuration mirrors similar requirements with floor call buttons (numbered 6-10) and comparable control panel dimensions and material specifications. Both elevator types feature adjustable width parameters of approximately 9 feet per elevator manufacturer specifications, with standardized door-side orientations and material finishes including LVT-1 (luxury vinyl tile) flooring. The wall elevations (north, south, east, and west) for both elevator types demonstrate consistent finish specifications with SS-1 and HPL-1 materials positioned at designated heights. The drawing set is dated March 30, 2026, and represents the Department of Veterans Affairs' comprehensive elevator standards for facility design and construction projects.

View the file

Other files

File Type Posted
36C77626B0007 0004.pdf PDF
ATTACHMENT 06_ALL CLINs - Master Spreadsheet Nationwide Elevator Modernization_05282026.xlsx XLSX spreadsheet
Attachment 10 - ALL CLINs - Step 1 Tech Questions Tracker 05192026.pdf PDF
36C77626B0007 0003.pdf PDF
Attachment 01_ALL CLINs - SCOPE Nationwide Elevator Modernization_05192026.pdf PDF
36C77626B0007 0002.pdf PDF
36C77626B0007 0001.pdf PDF
Attachment 10 - ALL CLINs - Step 1 Tech Questions Tracker.pdf PDF
ATTACHMENT 9E - CLINs 0076-0101 Wage Determinations.zip ZIP file
36C77626B0007_1_Final.pdf PDF
Attachment 05_ALL CLINs Milestone Payment Schedule_0403.pdf PDF
Attachment 08_CLINS 0001-0013 ONLY - Limitations on Subcontracting.pdf PDF
ATTACHMENT 9A - CLINs 0001-0013 Wage Determinations.zip ZIP file
Attachment 01_ALL CLINs - Scope Nationwide Elevator Modernization_04162026.pdf PDF
ATTACHMENT 9D - CLINs 0054-0075 Wage Determinations.zip ZIP file
Attachment 07_ALL CLINs - Past Performance Questionnaire.pdf PDF
ATTACHMENT 06_ALL CLINs - Master Spreadsheet Nationwide Elevator Modernization_04222026.xlsx XLSX spreadsheet
ATTACHMENT 9B - CLINs 0014-0034 Wage Determinations.zip ZIP file
Attachment 04_ALL CLINs - H18-8 Seismic Design Requirements.pdf PDF
ATTACHMENT 9C - CLINs 0035-0053 Wage Determinations.zip ZIP file
Attachment 02_ALL CLINs - Specifications Nationwide Elevator Modernization_05062026.pdf PDF
Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

- 9

'-0 " P

ER

E

LE

V.

M

FR

EXIST

WIDTH

LVT-1

FLOOR CALL

SS-1

SS-1

SS-1

SS-1

HPL-1 HPL-1 HPL-1

2' -6

SS-1

CL

CL SS-1

3' -6

D O

O R

S

ID

E

OPT. CAR

CONTROLS

HPL-1HPL-1HPL-1

SS-1

SS-1

SS-1 SS-1 SS-1

SS-1

3' -6

" SS-1

SS-1

2' -6

CL

CL

SS-1

SS-1

SS-1

42" MIN

CAR

CONTROL

PANEL

" M

IN

EM

ER

G

EN

C

Y

BU

TT

O

N S

" M

AX

CL

D O

O R

S

ID

E

D O

O R

S

ID

E

HPL-1HPL-1HPL-1

SS-1

SS-1

SS-1 SS-1 SS-1

SS-1

3' -6

" SS-1

SS-1

2' -6

CL

CL

- 9

'-0 " P

ER

E

LE

V.

M

FR

EXIST

WIDTH

SVT-1

FLOOR CALL

BUTTONS

3' -6

SS-1

SS-1

SS-1

SS-1

SS-1 SS-1 SS-1

D O

O R

S

ID

E

SS-1SS-1SS-1

SS-1

SS-1

SS-1 SS-1 SS-1

SS-1

SS-1

SS-1

SS -1

48" MIN

" M

IN

EM

ER

G

EN

C

Y

BU

TT

O

N S

" M

AX

CL

CAR

CONTROL

PANEL

SS-1SS-1SS-1

SS-1

SS-1

SS-1 SS-1 SS-1

D O

O R

S

ID

E

EQ

EQ

EQ

EQ

EQ EQ EQ

EQ

EQ

EQ

EQ

EQ EQ EQ

0 6" 1' 2' 3' 1/2" = 1'-0"

PASSENGER ELEVATOR FLOOR PLAN

0 6" 1' 2' 3' 1/2" = 1'-0"

NORTH WALL ELEV.

\\192.168.100.28\1.Projects.Current\18.10 IR Site Prep (SLC, UT)\4 - Design Phase\08 Submittals\100% CD Stamped Resubmittal\Native Files\18-10IRSitePrep-R18_mvanderploegB7QL4-US_Dept_of_Veterans_Affairs_logo_square-1917920.jpg

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: Project Director

VA FORM 08 - 6231

B

C

D

E

F

B

C

D

E

F

21 4 5 6 7 8 9

PhaseARCHITECT/ENGINEERS: STAMP:CONSULTANTS:

321 4 5 6 7 8 9

Issued: Date: VEG 18.10

Department of Veterans Affairs

Elevator Floor Plan, Elevations, and Ceiling Plan

Department of Veterans Affairs' Elevator Standards

CE03.30.2026

0 6" 1' 2' 3' 1/2" = 1'-0"

EAST WALL ELEV.

0 6" 1' 2' 3' 1/2" = 1'-0"

SOUTH EALL ELEV.

0 6" 1' 2' 3' 1/2" = 1'-0"

WEST WALL ELEV.

0 6" 1' 2' 3' 1/2" = 1'-0"

SERVICE ELEVATOR FLOOR PLAN

0 6" 1' 2' 3' 1/2" = 1'-0"

NORTH WALL ELEV.

0 6" 1' 2' 3' 1/2" = 1'-0"

EAST WALL ELEV.

0 6" 1' 2' 3' 1/2" = 1'-0"

SOUTH WALL ELEV.

0 6" 1' 2' 3' 1/2" = 1'-0"

WEST WALL ELEV.

0 6" 1' 2' 3' 1/2" = 1'-0"

CLG. KIT PER ELEVATOR MFR.

0 6" 1' 2' 3' 1/2" = 1'-0"

CLG. KIT PER ELEVATOR MFR.