Corrected_Replacement_Page_C-10.pdf
PDF 8 KB Posted
- Attached to
- National Mobile Shower Facilities
- Solicitation number
- AG-024B-S-12-9030
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Summary_of_Awards_AG-024B-S-12-9030_-_Corrected.pdf | ||
| Summary_of_Awards_AG-024B-S-12-9030.pdf | ||
| Exhibit_L.1_Revised_per_Amendment_01.docx | DOCX document | |
| Mobile_Shower_Solicitation_Q_and_As.pdf | ||
| Amendment_01.pdf | ||
| Section_B.1_ _B.2.docx | DOCX document | |
| Exhibit_L.2.docx | DOCX document | |
| Exhibit_L.1.docx | DOCX document | |
| Solicitation_AG-024B-S-12-9030.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation No. AG-024B-S-12-9030 U.S. Forest Service National Mobile Shower Facilities National Office
SECTION C
DESCRIPTION/SPECIFICATIONS/STATEMENT OF WORK
C-10 Amendment 01
(8) Be located inside of the shower trailer. Tent systems connected to the shower trailer are not acceptable.
(9) Provide for privacy from outside viewing.
(d) Potable Water Vehicle
All potable water vehicles shall:
(1) Provide a minimum capacity of 1,500 gallons of potable water storage and be available to provide the shower unit with potable water.
(2) Comply with the National Wildfire Coordinating Group (NWCG) potable water standards in Section J.1 and J.1A, and with any Department of Transportation and Water Quality Authority requirements of the State in which the potable water vehicle is licensed and performing work.
(3) Provide Contractor furnished operator(s).
(4) Be equipped with a minimum of four (4) outside spigots/valves for filling canteens, cubitainers and water bottles.
(5) Have a potable water/food-grade pump, which has the capacity to transfer potable water a minimum of twenty feet vertical.
(e) Sanitation Requirements
The entire inside of the Mobile Shower Facilities Unit shall be sanitized, at a minimum, twice daily (during non-peak periods) using the minimum following procedure:
(1) Wash down the MSFU with soap or detergent, rinse thoroughly, sanitize with a household bleach (5 percent chlorine) solution using a minimum of 1 tablespoon bleach per 2 gallons water, or equivalent and rinse unit thoroughly.
(2) Remove and sanitize floor mats twice daily.
(3) Shower curtains shall be sanitized twice daily and replaced as necessary.
(4) Maintain a log documenting the dates and times that the sanitizing is performed.
(5) Include the annual inspection certificate for the double check valve that documents it has been inspected and is fully operational.
(f) Additional Safety Equipment
Any steps or platforms shall have solid handrails, not chain linked, in addition to other current OSHA standards for handrails and stairs (see 29 CFR 1910.23-1910.24). All Stationary equipment shall be supplied with oil spill containment units consisting of both pads and pans, under the fuel tank, engine, and any other petroleum containers, except miscellaneous “fuel containers” under 5 gallons. Stationary equipment is defined as that remaining in one position for 24 hours or more, or that is parked in the same location for over 24 hours.
File details come from the government source that posted it. Updated .