Addenda #3 - Full Sized Drawings.pdf

PDF 2 MB Posted

Attached to
Replace Windows – Maxcy Hall
Solicitation number
2137241
Issued by
St. Lawrence County, New York

About this file

This addendum document provides full-sized architectural drawings for the Maxcy Hall Window Replacement project at SUNY Potsdam, located at 44 Pierrepont Avenue, Potsdam, New York. Addenda #3, issued July 22, 2026, contains no changes to the scope of work but includes detailed construction drawings for the window replacement project. The drawings package includes a sheet list with general and architectural elements covering partial third floor plans, windows plans, exterior elevations (north, south, and west), wall sections and details, and window schedules. The project involves replacement of windows at multiple locations within Maxcy Hall, with specific attention to the third floor gym, store, office, dance studio, corridor, elevator, mechanical room, press room, and storage areas. An optional walk-through was scheduled for July 23, 2026, with questions due July 27, 2026 by 3:00 p.m. and answers to be posted by July 29, 2026. Sealed bids were due August 10, 2026 at 3:00 p.m., with an estimated physical project start date of November 16, 2026 and completion by April 30, 2027.

The project is valued at $485,125 and is designated as a prevailing wage project under New York State Finance Law 139 j&k. All contractors and subcontractors must hold a current New York State Department of Labor Certificate of Registration effective December 30, 2024, and must submit a State Finance Law 139-m affidavit with their bid. The drawings show detailed specifications for window replacement work, including removal of existing glazing and bar stops, installation of new tempered, double-glazed, insulated, argon-filled panels, steel frame repairs and repainting, mullion installations, and sealant work. The existing structural steel elements, including channels, angles, plates, and bolts, are to remain in place with cleaning, welding repair, and repainting as required.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET LIST

GENERAL

G001 PH2 ARCHITECTURAL COVER SHEET

ARCHITECTURAL

A104 PARTIAL THIRD FLOOR PLAN

A105 WINDOWS PLAN

A201 EXTERIOR ELEVATIONS

A202 EXTERIOR ELEVATIONS

A203 EXTERIOR ELEVATIONS

A311 WALL SECTIONS AND DETAILS

A312 WALL SECTIONS AND DETAILS

A313 WALL SECTIONS AND DETAILS

A314 WALL SECTIONS AND DETAILS

A611 WINDOW SCHEDULE

A612 WINDOW SCHEDULE

La Be lla Po w er ed b y pa rt ne rs hi p.

/2 9/

BI

D

M

AX

CY

H

AL

L

W

IN

DO

W

R

EP

LA

CE

M

EN

T

SU

NY

P

OT

SD

AM

P

IE

RR

EP

ON

T

AV

E, P

OT

SD

AM

, N

Y

22 Depot St., Suite 16 Potsdam, NY 13676

(315) 268-1338

MAXCY HALL WINDOW REPLACEMENT

44 PIERREPONT AVE, POTSDAM, NY 13676

44 PIERREPONT AVE.

POTSDAM, NY 13676

MAXCY HALL

SARANAC LAKE DR

TU

PP

ER

LA

KE

D

R

OGDENSBURG DR

CA

NT

ON

D

R

CA

NT

ON

D R

MASSENA DR

WATERTOWN DRWATERTOWN DR

MASSENA DR

BA

RR

IN

GT

ON

D

R

BA

RR

IN

GT

ON

D R

BA

RR

IN

GT

ON

D

R

POTSDAM DR

PO

TS

DA

M

DR

SUNY POTSDAM

APPROXIMATE

LOCATION OF

PROJECT

Addenda #3 ~ 7/22/2026

Please note the following addenda/changes in the bid proposal. All bids received will be in accordance with these addenda. All other specifications, terms and conditions remain the same.

Full sized drawings - no changes to the scope of work.

7139 SF

GYM

490 SF

STORE

145 SF

OFFICE

3449 SF

DANCE STUDIO

3836 SF

THIRD FLOOR

CORRIDOR

85 SF

ELEV

239 SF

MECH

420 SF

PRESS

227 SF

Room

48 SF

STOR

48 SF

STOR

A105

A105

A105

DRAWING NAME:

DRAWING NUMBER:

DATE:

ISSUED FOR:

DRAWN BY:

REVIEWED BY:

PROJECT NUMBER:

It is a violation of New York Education Law Art. 145 Sec. 7209 & Art. 147 Sec. 7307, for any person, unless acting under the direction of a licensed architect, professional engineer, or land surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the alteration.

CERTIFICATE OF AUTHORIZATION NUMBER:

PROFESSIONAL ENGINEERING: 0021659

LAND SURVEYING: 0021272

GEOLOGICAL: 0021271

6/

/2

2:

:4

PM

A104

PARTIAL THIRD FLOOR

PLAN

JZ

MF

06/29/2026

BID

2261184

44 PIERREPONT AVE, POTSDAM, NY 13676

MAXCY HALL WINDOW

REPLACEMENT

SUNY POTSDAM

44 PIERREPONT AVE, POTSDAM, NY 13676

© 2020 LaBella Associates

22 Depot St., Suite 16 Potsdam, NY 13676

(315) 268-1338

SCALE: 1/8" = 1'-0"A104

1 PARTIAL THIRD FLOOR PLAN

MAXCY HALL KEY PLAN

N

N

Revisions

NO: DATE: DESCRIPTION:

GYM

THIRD FLOOR

CORRIDOR

0"

A311

A311

A201

DANCE STUDIO

THIRD FLOOR

CORRIDOR

8'

- 0

A311

A311

A202

DANCE STUDIO

STOR

0"

A312

A312

A312

A312

A202

DRAWING NAME:

DRAWING NUMBER:

DATE:

ISSUED FOR:

DRAWN BY:

REVIEWED BY:

PROJECT NUMBER:

It is a violation of New York Education Law Art. 145 Sec. 7209 & Art. 147 Sec. 7307, for any person, unless acting under the direction of a licensed architect, professional engineer, or land surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the alteration.

CERTIFICATE OF AUTHORIZATION NUMBER:

PROFESSIONAL ENGINEERING: 0021659

LAND SURVEYING: 0021272

GEOLOGICAL: 0021271

6/

/2

2:

:4

PM

A105

WINDOWS PLAN

JZ

MF

06/29/2026

BID

2261184

44 PIERREPONT AVE, POTSDAM, NY 13676

MAXCY HALL WINDOW

REPLACEMENT

SUNY POTSDAM

44 PIERREPONT AVE, POTSDAM, NY 13676

© 2020 LaBella Associates

22 Depot St., Suite 16 Potsdam, NY 13676

(315) 268-1338

SCALE: 1/2" = 1'-0"A105

1 WINDOW 1 PLAN AT THIRD FLOOR

SCALE: 1/2" = 1'-0"A105

2 WINDOW 2 PLAN AT THIRD FLOOR

SCALE: 1/2" = 1'-0"A105

3 WINDOW 3 PLAN AT THIRD FLOOR

N

N

N

SECOND FLOOR

12' - 8"

HOCKEY RINLK/ CAGE ROOF

45' - 0"

THIRD FLOOR

22' - 4"

A311

W1

G.C. TO PROVIDE NEW HORIZONTAL MULLION

FRAMING TO MATCH EXISTING TO REMAIN

INSTALLED MULLION AT W2, SEE DETAIL 2/311

FOR MATERIALS TO MATCH AND INSTALL

G.C. TO REMOVE EXISTING INSTALLED

PLYWOOD FACADE AND INSPECTED EXISTING

STEEL AND WELD FOR DETERIORATION,

NOTIFY AOR OF ANY FINDINGS.

SEE SHEET A611

DRAWING NAME:

DRAWING NUMBER:

DATE:

ISSUED FOR:

DRAWN BY:

REVIEWED BY:

PROJECT NUMBER:

It is a violation of New York Education Law Art. 145 Sec. 7209 & Art. 147 Sec. 7307, for any person, unless acting under the direction of a licensed architect, professional engineer, or land surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the alteration.

CERTIFICATE OF AUTHORIZATION NUMBER:

PROFESSIONAL ENGINEERING: 0021659

LAND SURVEYING: 0021272

GEOLOGICAL: 0021271

6/

/2

2:

:4

PM

A201

EXTERIOR ELEVATIONS

JZ

MF

06/29/2026

BID

2261184

44 PIERREPONT AVE, POTSDAM, NY 13676

MAXCY HALL WINDOW

REPLACEMENT

SUNY POTSDAM

44 PIERREPONT AVE, POTSDAM, NY 13676

© 2020 LaBella Associates

22 Depot St., Suite 16 Potsdam, NY 13676

(315) 268-1338

SCALE: 1/4" = 1'-0"A201

1 PARTIAL ELEVATION NORTH

SECOND FLOOR

12' - 8"

HOCKEY RINLK/ CAGE ROOF

45' - 0"

A312

THIRD FLOOR

22' - 4"

W2

W3

A311

SEE SHEET A611

SEE SHEET A611

DRAWING NAME:

DRAWING NUMBER:

DATE:

ISSUED FOR:

DRAWN BY:

REVIEWED BY:

PROJECT NUMBER:

It is a violation of New York Education Law Art. 145 Sec. 7209 & Art. 147 Sec. 7307, for any person, unless acting under the direction of a licensed architect, professional engineer, or land surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the alteration.

CERTIFICATE OF AUTHORIZATION NUMBER:

PROFESSIONAL ENGINEERING: 0021659

LAND SURVEYING: 0021272

GEOLOGICAL: 0021271

6/

/2

2:

:4

PM

A202

EXTERIOR ELEVATIONS

JZ

MF

06/29/2026

BID

2261184

44 PIERREPONT AVE, POTSDAM, NY 13676

MAXCY HALL WINDOW

REPLACEMENT

SUNY POTSDAM

44 PIERREPONT AVE, POTSDAM, NY 13676

© 2020 LaBella Associates

22 Depot St., Suite 16 Potsdam, NY 13676

(315) 268-1338

SCALE: 1/4" = 1'-0"A202

1 PARTIAL ELEVATION SOUTH

FIRST FLOOR

0' - 0"

SECOND FLOOR

12' - 8"

HOCKEY RINLK/ CAGE ROOF

45' - 0"

THIRD FLOOR

22' - 4"

W4

DRAWING NAME:

DRAWING NUMBER:

DATE:

ISSUED FOR:

DRAWN BY:

REVIEWED BY:

PROJECT NUMBER:

It is a violation of New York Education Law Art. 145 Sec. 7209 & Art. 147 Sec. 7307, for any person, unless acting under the direction of a licensed architect, professional engineer, or land surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the alteration.

CERTIFICATE OF AUTHORIZATION NUMBER:

PROFESSIONAL ENGINEERING: 0021659

LAND SURVEYING: 0021272

GEOLOGICAL: 0021271

6/

/2

2:

:4

PM

A203

EXTERIOR ELEVATIONS

JZ

MF

06/29/2026

BID

2261184

44 PIERREPONT AVE, POTSDAM, NY 13676

MAXCY HALL WINDOW

REPLACEMENT

SUNY POTSDAM

44 PIERREPONT AVE, POTSDAM, NY 13676

© 2020 LaBella Associates

22 Depot St., Suite 16 Potsdam, NY 13676

(315) 268-1338

SCALE: 1/4" = 1'-0"A203

1 PARTIAL ELEVATION WEST

Revisions

SEE SHEET A612

8"

1"

37' - 4"

EXISTING WEEP HOLES TO REMIAN

EXISTING FLASHING TO REMAIN

EXISTING 3/8" BOLTS @ 30" OC TO REMAIN

EXISTING (2) 4" X 4" X 1/4" STEEL ANGLES TO REMAIN

EXISTING 13" X 3/8" STEEL PLATE TO REMAIN

EXISTING 3" X 2" X 1/4" STEEL ANGLE TO REMAIN

EXISTING 8" X 1/2" STEEL PLATE TO REMAIN

EXISTING (2)3/8" FLATHEADS @ 24"

OC TO REMAIN

8"

3/4"

EXISTING 1/2" BLOT @ 20" OC TO

REMAIN

EXISTING 14" SHIM TO REMAIN

1/2" @ 20" OC GC. TO INSPECT

EXISTING DIFFUSER TO REMAIN

3/4"

3/4"

3/4

1' - 2"

EXISTING 8" CHANNEL TO REMAIN

REMOVE EXISTING 3/4" BAR STOPS.

PROVIDE AND INSTALL NEW

EXISTING 8" X 1/2" STEEL PLATE

TO REMAIN

EXISTING 8" X 1/2" STL TO REMAIN

EXISTING 6" STEEL CHANNEL TO REMAIN

EXISTING 4" STEEL CHANNEL TO REMAIN

22' - 4"

EXISTING 6" STEEL CHANNEL TO REMAIN

EXISTING 4" STEEL CHANNEL TO REMAIN

1' - 2"

MULLION AT 3RD FLOOR F.F.

B.O.M.O. T.O. STEEL

EXISTING STEEL JAMBS TO REMAIN

EXISTING STEEL JAMBS TO REMAIN

EXISTING STEEL JAMBS TO REMAIN

EXISTING STEEL JAMBS TO REMAIN

EXISTING STEEL JAMBS TO REMAIN

REMOVE EXISTING 3/4" BAR STOPS.

PROVIDE AND INSTALL NEW

REMOVE EXISTING 3/4" GLAZING. PROVIDE AND

INSTALL NEW TEMPERED, DOUBLE GLAZED,

INSULATED, ARGON FILLED PANELS

REMOVE EXISTING 3/4" STEEL BAR

STOPS. PROVIDE AND INSTALL NEW

REMOVE EXISTING 3/4" GLAZING. PROVIDE AND

INSTALL NEW TEMPERED, DOUBLE GLAZED,

INSULATED, ARGON FILLED PANELS

REMOVE EXISTING 3/4" BAR STOPS.

PROVIDE AND INSTALL NEW

REMOVE EXISTING 3/4" GLAZING. PROVIDE AND

INSTALL NEW TEMPERED, DOUBLE GLAZED,

INSULATED, ARGON FILLED PANELS

REMOVE EXISTING 3/4" BAR STOPS.

PROVIDE AND INSTALL NEW

REMOVE EXISTING 3/4" GLAZING. PROVIDE AND

INSTALL NEW TEMPERED, DOUBLE GLAZED,

INSULATED, ARGON FILLED PANELS

NOTES:

G.C. TO CLEAN AND REPAIR ALL

WELDS.

G.C. TO CLEAN AND PREP ALL

EXISTING STEEL TO RECEIVE

NEW PRIMER AND PAINT

FINISHES.

G.C. TO PROTECT ALL EXISTING

FINISHES TO REMAIN. (TYPICAL)

NOTES:

G.C. TO CLEAN AND REPAIR ALL

WELDS.

G.C. TO CLEAN AND PREP ALL

EXISTING STEEL TO RECEIVE NEW

PRIMER AND PAINT FINISHES.

G.C. TO PROTECT ALL EXISTING

FINISHES TO REMAIN. (TYPICAL)

NEW MULLION "W1": G.C. TO

INSTALL MULLION WITH SIMILAR

MATERIAL AND CONSRUCTION AS

EXISTING W2 HORIZONTAL MULLION

NOTES:

G.C. TO CLEAN AND REPAIR ALL

WELDS.

G.C. TO CLEAN AND PREP ALL

EXISTING STEEL TO RECEIVE

NEW PRIMER AND PAINT

FINISHES.

G.C. TO PROTECT ALL EXISTING

FINISHES TO REMAIN. (TYPICAL)

(NEW W1 MULLION SIMILAR)

8"

EXISTING 1/4" ANCHOR BOLTS TO REMAIN

EXISTING 3/8" FLATHEAD TO REMAIN

3/4

1/2

1"

REMOVE EXISTING 3/4" STEEL BAR

STOPS. PROVIDE AND INSTALL NEW

REMOVE EXISTING 3/4" GLAZING.

PROVIDE AND INSTALL NEW

TEMPERED, DOUBLE GLAZED,

INSULATED, ARGON FILLED PANELS

8"

EXISTING 8" CHANNEL TO REMAIN

EXISTING 4" X 3 1/2" LS TO REMAIN

1' - 2"

EXISTING STEEL SILL TO REMAIN

REMOVE EXISTING SEALANT AND REPLACE NEW

NOTES:

G.C. TO CLEAN AND REPAIR ALL

WELDS.

G.C. TO CLEAN AND PREP ALL

EXISTING STEEL TO RECEIVE

NEW PRIMER AND PAINT

FINISHES.

G.C. TO PROTECT ALL EXISTING

FINISHES TO REMAIN. (TYPICAL)

EXISTING DIFFUSER TO REMAIN

EXISTING WD BLOCK TO REMAIN

REMOVE EXISTING EXTERIOR

CAULKING, CLEAN AND PREP TO

INSTALL NEW

EXISTING FLASHING TO REMAIN

8"

14' - 8"

1' - 2"

EXISTING 6 1/2" X 3 1/2" STEEL ANGLE TO REMAIN

EXISTING 6" STEEL CHANNEL TO REMAIN

EXISTING 8" X 1/2" STEEL PLATE TO REMAIN

B.O. STEEL FRAMING

EXISTING STEEL JAMBS TO REMAIN

EXISTING BRICK FACADE TO REMAIN

REMOVE EXISTING 3/4" STEEL BAR

STOPS. PROVIDE AND INSTALL NEW

REMOVE EXISTING 3/4" GLAZING. PROVIDE AND

INSTALL NEW TEMPERED, DOUBLE GLAZED,

INSULATED, ARGON FILLED PANELS

NOTES:

G.C. TO CLEAN AND REPAIR ALL

WELDS.

G.C. TO CLEAN AND PREP ALL

EXISTING STEEL TO RECEIVE

NEW PRIMER AND PAINT

FINISHES.

G.C. TO PROTECT ALL EXISTING

FINISHES TO REMAIN. (TYPICAL) DRAWING NAME:

DRAWING NUMBER:

DATE:

ISSUED FOR:

DRAWN BY:

REVIEWED BY:

PROJECT NUMBER:

It is a violation of New York Education Law Art. 145 Sec. 7209 & Art. 147 Sec. 7307, for any person, unless acting under the direction of a licensed architect, professional engineer, or land surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the alteration.

CERTIFICATE OF AUTHORIZATION NUMBER:

PROFESSIONAL ENGINEERING: 0021659

LAND SURVEYING: 0021272

GEOLOGICAL: 0021271

6/

/2

3:

:3

PM

A311

WALL SECTIONS AND

DETAILS

JZ

MF

06/29/2026

BID

2261184

44 PIERREPONT AVE, POTSDAM, NY 13676

MAXCY HALL WINDOW

REPLACEMENT

SUNY POTSDAM

44 PIERREPONT AVE, POTSDAM, NY 13676

© 2020 LaBella Associates

22 Depot St., Suite 16 Potsdam, NY 13676

(315) 268-1338

A311

W1, W2 HEAD SECTION DETAIL

SCALE: 3" = 1'-0"

A311

W2 HORIZONTAL MULLION SECTION DETAIL

SCALE: 3" = 1'-0"

A311

W1, W2 SILL SECTION DETAIL

SCALE: 3" = 1'-0"3

A311

W1, W2 MULLION SECTION DETAIL

SCALE: 3" = 1'-0"

A311

W1, W2 JAMB SECTION DETAIL

SCALE: 3" = 1'-0"

1' - 2"

1' - 2"

37' - 4"

22' - 4"

EXISTING WEEP HOLES TO REMAIN

EXISTING FLASHING TO REMAIN

1' - 2"

EXISTING 3/8" BOLTS @ 30" OC TO REMAIN

EXISTING (2)4" X 4" X 1/4" STEEL ANGLES TO REMAIN

EXISTING 13" X 3/8" STEEL PLATE TO REMAIN

EXISTING 3" X 2" X 1/4" STEEL ANGLE TO REMAIN

EXISTING 8" X 1/2" STEEL PLATE TO REMAIN

EXISTING (2)3/8" FLATHEADS @ 24" OC TO REMAIN1"

8"

EXISTING 14" SHIM TO REMAIN

EXISTING 1/2" BLOTS @ 20" OC TO REMAIN

REMOVE EXISTING EXTERIOR CAULKING,

CLEAN AND PREP TO INSTALL NEW

EXISTING DIFFUSER TO REMAIN

8"

EXISTING WD BLOCK TO REMAIN

3/4"

3/4

8"

3/4

1"

REMOVE EXISTING 3/4" STEEL BAR STOPS.

PROVIDE AND INSTALL NEW

REMOVE EXISTING 3/4" GLAZING. PROVIDE

AND INSTALL NEW TEMPERED, DOUBLE

GLAZED, INSULATED, ARGON FILLED PANELS1' - 2"

EXISTING STEEL JAMB TO REMAIN

REMOVE EXISTING 3/4" STEEL BAR

STOPS. PROVIDE AND INSTALL NEW

EXISTING 8" X 1/2" STEEL PLATE TO REMAIN

REMOVE EXISTING 3/4" STEEL BAR

STOPS. PROVIDE AND INSTALL NEW

EXISTING 6" CHANNEL TO REMAIN

EXISTING 4" CHANNEL TO REMAIN

EXISTING 6" STEEL CHANNEL TO REMAIN

REMOVE EXISTING 3/4" STEEL BAR

STOPS. PROVIDE AND INSTALL NEW

REMOVE EXISTING 3/4" GLAZING. PROVIDE AND

INSTALL NEW TEMPERED, DOUBLE GLAZED,

INSULATED, ARGON FILLED PANELS

EXISTING FLASHING TO REMAIN

B.O.M.O. T.O. STEEL

B.O. STEEL FRAMING AT THIRD FLOOR F.F.

REMOVE EXISTING 3/4" GLAZING. PROVIDE AND

INSTALL NEW TEMPERED, DOUBLE GLAZED,

INSULATED, ARGON FILLED PANELS

EXISTING BRICK FACADE TO REMAIN

EXISTING BRICK FACADE TO REMAIN

NOTES:

G.C. TO CLEAN AND REPAIR ALL

WELDS.

G.C. TO CLEAN AND PREP ALL

EXISTING STEEL TO RECEIVE

NEW PRIMER AND PAINT

FINISHES.

G.C. TO PROTECT ALL EXISTING

FINISHES TO REMAIN. (TYPICAL)

NOTES:

G.C. TO CLEAN AND REPAIR ALL

WELDS.

G.C. TO CLEAN AND PREP ALL

EXISTING STEEL TO RECEIVE

NEW PRIMER AND PAINT

FINISHES.

G.C. TO PROTECT ALL EXISTING

FINISHES TO REMAIN. (TYPICAL)

NOTES:

G.C. TO CLEAN AND REPAIR ALL

WELDS.

G.C. TO CLEAN AND PREP ALL

EXISTING STEEL TO RECEIVE

NEW PRIMER AND PAINT

FINISHES.

G.C. TO PROTECT ALL EXISTING

FINISHES TO REMAIN. (TYPICAL)

8"

2"

8"

3/4"

1"

1"

1"

EXISTING 8" X 1/2" STEEL PLATE TO REMAIN

EXISTING 4" X 1 5/8" STEEL CHANNEL TO REMAIN

EXISTING 6" X 2" STEEL CHANNEL TO REAMIN

EXISTING 1/2" BOLT @ 30" OC TO REMAIN

EXISTING 1/4" ANCHOR BOLTS TO REMAIN

EXISTING 8" STEEL CHANNEL TO REMAIN

EXISTING 4" X 3 1/2" STEEL ANGLE TO REMAIN

EXISTING 1/2" FLATHEAD TO REMAIN3/4

1' - 2"

8"

4"

8"

8"

2"

EXISTING 6" STEEL CHANNEL TO REMAIN

EXISTING 4" STEEL CHANNEL TO REMAIN

1' - 2"

EXISTING 8" X 1/2" STEEL PLATE TO REMAIN

EXISTING STEEL JAMB TO REMAIN

EXISTING STEEL JAMB TO REMAIN

EXISTING 8" X 1/2" STEEL PLATE TO REMAIN

REMOVE EXISTING 3/4" STEEL BAR

STOPS. PROVIDE AND INSTALL NEW

REMOVE EXISTING 3/4" STEEL BAR

STOPS. PROVIDE AND INSTALL NEW

8" 4"2"

REMOVE EXISTING 3/4" STEEL BAR

STOPS. PROVIDE AND INSTALL NEW

EXISTING STEEL JAMB TO REMAIN

1' - 2"

REMOVE EXISTING 3/4" STEEL BAR

STOPS. PROVIDE AND INSTALL NEW

REMOVE EXISTING 3/4" GLAZING.

PROVIDE AND INSTALL NEW TEMPERED,

DOUBLE GLAZED, INSULATED, ARGON

FILLED PANELS

REMOVE EXISTING 3/4" GLAZING.

PROVIDE AND INSTALL NEW TEMPERED,

DOUBLE GLAZED, INSULATED, ARGON

FILLED PANELS

REMOVE EXISTING SEALANT AND REPLACE NEW

REMOVE EXISTING 3/4" GLAZING. PROVIDE

AND INSTALL NEW TEMPERED, DOUBLE

GLAZED, INSULATED, ARGON FILLED PANELS

NOTES:

G.C. TO CLEAN AND REPAIR ALL

WELDS.

G.C. TO CLEAN AND PREP ALL

EXISTING STEEL TO RECEIVE

NEW PRIMER AND PAINT

FINISHES.

G.C. TO PROTECT ALL EXISTING

FINISHES TO REMAIN. (TYPICAL)

NOTES:

G.C. TO CLEAN AND REPAIR ALL

WELDS.

G.C. TO CLEAN AND PREP ALL

EXISTING STEEL TO RECEIVE

NEW PRIMER AND PAINT

FINISHES.

G.C. TO PROTECT ALL EXISTING

FINISHES TO REMAIN. (TYPICAL)

3/4"

NOTES:

G.C. TO CLEAN AND REPAIR ALL

WELDS.

G.C. TO CLEAN AND PREP ALL

EXISTING STEEL TO RECEIVE

NEW PRIMER AND PAINT

FINISHES.

G.C. TO PROTECT ALL EXISTING

FINISHES TO REMAIN. (TYPICAL)

DRAWING NAME:

DRAWING NUMBER:

DATE:

ISSUED FOR:

DRAWN BY:

REVIEWED BY:

PROJECT NUMBER:

It is a violation of New York Education Law Art. 145 Sec. 7209 & Art. 147 Sec. 7307, for any person, unless acting under the direction of a licensed architect, professional engineer, or land surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the alteration.

CERTIFICATE OF AUTHORIZATION NUMBER:

PROFESSIONAL ENGINEERING: 0021659

LAND SURVEYING: 0021272

GEOLOGICAL: 0021271

6/

/2

2:

:4

PM

A312

WALL SECTIONS AND

DETAILS

JZ

MF

06/29/2026

BID

2261184

44 PIERREPONT AVE, POTSDAM, NY 13676

MAXCY HALL WINDOW

REPLACEMENT

SUNY POTSDAM

44 PIERREPONT AVE, POTSDAM, NY 13676

© 2020 LaBella Associates

22 Depot St., Suite 16 Potsdam, NY 13676

(315) 268-1338

A312

W3 HEAD SECTION DETAIL

SCALE: 3" = 1'-0"

A312

W3 HORIZONTAL MULLION SECTION DETAIL

SCALE: 3" = 1'-0"

A312

W3 SILL SECTION DETAIL

SCALE: 3" = 1'-0"

A312

W3 JAMB SECTION DETAIL

SCALE: 3" = 1'-0"

A312

W3 VERTICAL MULLION SECTION DETAIL

SCALE: 3" = 1'-0"

A312

W3 JAMB SECTION DETAIL

SCALE: 3" = 1'-0"

A313

A313

A313

48' - 0"

1' - 8"

1'

- 6

1"

M. O.

1' - 2"

3 1/2" 4 1/2" 4 1/2"

3/4" 4 1/2" 4 1/2"

45' - 11 3/4"

8' - 10 3/4" 8' - 10 3/4" 8' - 10 3/4" 8' - 10 3/4" 8' - 10 3/4"

4"

A313

A313

A313

LEFT JAMB SECTION DETAIL EXISTING VERTICAL MULLION SECTION DETAIL RIGHT JAMB SECTION DETAIL

EXISTING 3" x 3" x 5/6" STEEL ANGLE

EXISTING 18" x 1/2" STEEL PLATE

EXISTING BAR STOP

EXISTING 12" x 1/2" STEEL CHANNEL

EXISTING 1/2" x 25" STEEL PLATE

1/2" Ø BOLT @ 30" O.C

1/2"

1/2"

EXISTING 14" STEEL BENT PLATE

1 1 /2"

3/4" 3/4

3/4"

3/4

3/4

EXISTING 15" CHANNEL PRIME AND PAINT

EXISTING 9" x 2 1/2" STEEL CHANNEL

EXISTING 18" x 1/2" PLATE PRIME AND PAINT

SCALE: 1 1/2" = 1'-0" SCALE: 1 1/2" = 1'-0" SCALE: 1 1/2" = 1'-0"

1'

- 6

1 1 /2"

3 1/2"

1"

EXISTING STEEL SILL AND FRAMING,

REPAIR ALL WELDS, PRIME AND PAINT

G.C. TO EXISTING ACM WINDOW CAULKING REMEDIATION TO

INCLUDE REMOVAL OF EXISTING STOPS AND GLAZING. INSTALL

NEW 3/4" TEMPERED GLASS WITH SEALANT. REPLACE EXISTING

PAINTED STEEL 3/4" X 3/4" STOPS AS REQUIRED (TYP.)

EXISTING STEEL SILL AND FRAMING, REPAIR ALL

WELDS, PRIME AND PAINT

EXISTING STEEL SILL AND

FRAMING, REPAIR ALL WELDS,

PRIME AND PAINT

G.C. TO EXISTING ACM WINDOW CAULKING REMEDIATION TO

INCLUDE REMOVAL OF EXISTING STOPS AND GLAZING. INSTALL NEW

3/4" TEMPERED GLASS WITH SEALANT. REPLACE EXISTING PAINTED

STEEL 3/4" X 3/4" STOPS AS REQUIRED (TYP.)

EXISTING 3/4" x 3/4" STEEL BAR STOPS

G.C. TO INSPECT EXISTING WELD, REPAIR AS

REQ'D. AND PRIME AND PAINT EXISTING STEEL.

G.C. TO INSPECT EXISTING WELD, REPAIR AS

REQ'D. AND PRIME AND PAINT EXISTING STEEL.

G.C. TO EXISTING ACM WINDOW CAULKING

REMEDIATION TO INCLUDE REMOVAL OF STOPS

AND GLAZING. INSTALL NEW 3/4" TEMPERED GLASS

WITH SEALANT. REPLACE EXISTING PAINTED STEEL

3/4" X 3/4" STOPS AS REQUIRED (TYP.)

DRAWING NAME:

DRAWING NUMBER:

DATE:

ISSUED FOR:

DRAWN BY:

REVIEWED BY:

PROJECT NUMBER:

It is a violation of New York Education Law Art. 145 Sec. 7209 & Art. 147 Sec. 7307, for any person, unless acting under the direction of a licensed architect, professional engineer, or land surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the alteration.

CERTIFICATE OF AUTHORIZATION NUMBER:

PROFESSIONAL ENGINEERING: 0021659

LAND SURVEYING: 0021272

GEOLOGICAL: 0021271

6/

/2

2:

:5

PM

A313

WALL SECTIONS AND

DETAILS

JZ

MF

06/29/2026

BID

2261184

44 PIERREPONT AVE, POTSDAM, NY 13676

MAXCY HALL WINDOW

REPLACEMENT

SUNY POTSDAM

44 PIERREPONT AVE, POTSDAM, NY 13676

© 2020 LaBella Associates

22 Depot St., Suite 16 Potsdam, NY 13676

(315) 268-1338

SCALE: 1/2" = 1'-0"A313

1 OVERALL WINDOW SECTION

N

NEW 3/4" x 3/4" STEEL BAR STOPS TO

MATCH EXISTING (PAINTED)

1/2"

NEW 1/2" x 18" STEEL PLATE, SLOPED

NEW 1/2" x 18" STEEL PLATE (PAINTED)

EXISTING 1/2" x 18" STEEL PLATE (BEYOND)

EXISTING 1/2" x 18" STEEL PLATE (BEYOND)

NEW 2 1/2" x 1/4" STEEL BAR SHIM (PAINTED)

NEW C15x40 + NEW C9x15 (PAINTED)

NEW 3/4" x 3/4" PAINTED STEEL

BAR STOPS TO MATCH EXISTING

NEW 3/4" TEMPERED GLAZING

NEW 3/4" TEMPERED GLAZING

G. C. TO CLEAN, REPAIR DAMAGED WELDS

PRIME AND PAINT ALL EXISTING STEEL

G.C. TO EXISTING ACM WINDOW CAULKING REMEDIATION TO

INCLUDE REMOVAL OF STOPS AND GLAZING. INSTALL NEW

3/4" TEMPERED GLASS WITH SEALANT. REPLACE EXISTING

PAINTED STEEL 3/4" X 3/4" STOPS AS REQUIRED (TYP.)

EXISTING 3/4" x 3/4" ST BAR STOPS

EXISTING 13" X 1/2" STL PL

EXISTING 2 1/2" x 1/4" STL PL

EXISTING 15" X 3 1/2" STL CHANNEL

FASTEN TD COLUMNS

3 1 /2"

3/4"

1/2"

B. O. Steel Framing 10' - 4 5/8"

1 1/2"

NEW CONT.

FILLED WELD

NEW 3/4" TEMPERED GLAZING

1' - 0" NEW 4" x 12" x 1/4" STEEL COLUMN (46 ksi)

G. C. TO CLEAN, REPAIR

DAMAGED WELDS PRIME AND

PAINT ALL EXISTING STEEL

G.C. TO EXISTING ACM WINDOW

CAULKING REMEDIATION TO INCLUDE

REMOVAL OF STOPS AND GLAZING.

INSTALL NEW 3/4" TEMPERED GLASS

WITH SEALANT. REPLACE EXISTING

PAINTED STEEL 3/4" X 3/4" STOPS AS

REQUIRED (TYP.)

B. O. M.O. T. O. Steel 23' - 4"

EXISTING (2) 3 x 3 x 1/4" <S EXISTING 1/2" x 19 1/2" STEEL PLATE

EXISTING 15" x 3 1/2" CHANNEL

EXISTING 1/2" x 18" STEEL PLATE EXISTING 3/4" x 3/4" STEEL BAR STOPS

4"

1' - 8"

1' - 0"4"

1 1/2" 1"

1/2

3 1 /2"

G. C. TO CLEAN, REPAIR DAMAGED WELDS

PRIME AND PAINT ALL EXISTING STEEL

G.C. TO EXISTING ACM WINDOW

CAULKING REMEDIATION TO INCLUDE

REMOVAL OF STOPS AND GLAZING.

INSTALL NEW 3/4" TEMPERED GLASS

WITH SEALANT. REPLACE EXISTING

PAINTED STEEL 3/4" X 3/4" STOPS AS

REQUIRED (TYP.)

EXISTING CONC FOUNDATION WALL

EXISTING EXPANSION JOINT AT EXISTING

ASPHALT TRANSITION TO REMAIN. G.C.

TO REPLACE SEALANT AS REQ'D.

EXISTING ASPHALT PAVING TO REMAIN.

GC. TO PROTECT DURING CONSTRUCTION

NEW 14" x 13" x 1/2" STEEL BASE PLATE

NEW NON-SHRINK GROUT, MIN. 1" BED

EXISTING BRICK PAVING TO REMAIN.

G.C. TO REMOVE SECTION TO

INSTALL ANCHORS AND COLUMN.

SALVAGE REMOVED BRICK PAVING

FOR INSTALLATION.

EXISTING CONC. SLAB.

G.C. TO NOTIFY AOR OF BRICK

CONDITIONS DURING SELECTIVE

DEMOLITION AND REVIEW

FINDINGS.

NEW FILLET WELD

NEW DRILLED 1/2" DIA S.S. ANCHORS, 3"

MIN. EMBEDMENT W/ EPOXY(4-TYPICAL)

1' - 2"

10"

2" 2"

7" 7"

1' - 0"

8"

3/8"

1'

- 2

1' - 1"

2"

2"

2"

2"

9" 2"

1' - 0"

4"

CONT. FILLET WELD AT COLUMN BASE TO PLATE

NEW 4" x 12" x 1/4" STEEL COLUMN (46 ksi) (PAINTED)

3" 3"

2"

DRAWING NAME:

DRAWING NUMBER:

DATE:

ISSUED FOR:

DRAWN BY:

REVIEWED BY:

PROJECT NUMBER:

It is a violation of New York Education Law Art. 145 Sec. 7209 & Art. 147 Sec. 7307, for any person, unless acting under the direction of a licensed architect, professional engineer, or land surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the alteration.

CERTIFICATE OF AUTHORIZATION NUMBER:

PROFESSIONAL ENGINEERING: 0021659

LAND SURVEYING: 0021272

GEOLOGICAL: 0021271

6/

/2

2:

:5

PM

A314

WALL SECTIONS AND

DETAILS

JZ

MF

06/29/2026

BID

2261184

44 PIERREPONT AVE, POTSDAM, NY 13676

MAXCY HALL WINDOW

REPLACEMENT

SUNY POTSDAM

44 PIERREPONT AVE, POTSDAM, NY 13676

© 2020 LaBella Associates

22 Depot St., Suite 16 Potsdam, NY 13676

(315) 268-1338

SCALE: 3" = 1'-0"A314

2 NEW HORIZONTAL MULLION DETAIL

SCALE: 3" = 1'-0"A314

6 TYPICAL SILL

SCALE: 3" = 1'-0"A314

14 TYPICAL HEAD

SCALE: 3" = 1'-0"A314

9 NEW COLUMN FOUNDATION DETAIL

SCALE: 3" = 1'-0"A314

8 BASE PLATE DETAILS

8' - 0"

8"

10' - 0"

0"

15' - 0"

10' - 0"

7'

- 0

1/ 2"

5'

- 7

5'

- 3

7' - 0"

W2W1

W3

A311

A311

A311

A311

A311

A311

A311

A312

A312

A312

A312

14' - 8"

37' - 4"

A312

A312

A311 5A311

14' - 8"

37' - 4" 37' - 4"

22' - 4"

A311

B.O.M.O. T.O. STEEL

B.O. STEEL FRAMING

B.O.M.O. T.O. STEEL B.O.M.O. T.O. STEEL

B.O. STEEL FRAMING

B.O. STEEL FRAMING AT THIRD FLOOR F.F.

22' - 4"

SILL AT 3RD FLOOR F.F.SILL AT 3RD FLOOR F.F.

2"

2"

3/4"

2"

8'

- 6

1/ 2"

2"

3/4" 3/4" 2"

22' - 4"

2" 1/2

7'

- 0

1/ 2"

2"

8'

- 6

1/ 2"

5'

- 7

M. O. M. O. M. O.

M.

O

M.

O

M.

O

2"

2"

7' - 0"

G.C. TO REMOVE ACM WINDOW

CAULKING. REMEDIATION TO

INCLUDE REMOVAL OF STOPS

AND GLAZING. INSTALL NEW 3/4"

TEMPERED GLASS WITH NEW

SEALANT BEDS. INSTALL NEW

WINDOW SEALANT AND

CAULKING. REPLACE EXISTING

3/4" X 3/4" STOPS WITH NEW

STOPS (TYP.).

G. C. TO CLEAN, REPAIR

DAMAGED WELDS PRIME AND

PAINT ALL EXISTING STEEL

NEW GLAZING,

SEALANT AND STOPS

(TYPICAL)

G.C. TO PROTECT

EXISTING BRICK

FACADE (TYP.)

G.C. TO PROTECT

EXISTING BRICK

FACADE (TYP.)

G.C. TO PROTECT

EXISTING BRICK

FACADE (TYP.)

G.C. TO REMOVE ACM WINDOW

CAULKING. REMEDIATION TO

INCLUDE REMOVAL OF STOPS

AND GLAZING. INSTALL NEW 3/4"

TEMPERED GLASS WITH NEW

SEALANT BEDS. INSTALL NEW

WINDOW SEALANT AND

CAULKING. REPLACE EXISTING

3/4" X 3/4" STOPS WITH NEW

STOPS (TYP.).

G. C. TO CLEAN, REPAIR

DAMAGED WELDS PRIME AND

PAINT ALL EXISTING STEEL

NEW GLAZING,

SEALANT AND STOPS

(TYPICAL)

G.C. TO REMOVE ACM WINDOW

CAULKING. REMEDIATION TO

INCLUDE REMOVAL OF STOPS

AND GLAZING. INSTALL NEW 3/4"

TEMPERED GLASS WITH NEW

SEALANT BEDS. INSTALL NEW

WINDOW SEALANT AND

CAULKING. REPLACE EXISTING

3/4" X 3/4" STOPS WITH NEW

STOPS (TYP.).

G. C. TO CLEAN, REPAIR

DAMAGED WELDS PRIME AND

PAINT ALL EXISTING STEEL

NEW GLAZING,

SEALANT AND STOPS

(TYPICAL)

G.C. TO PROVIDE NEW HORIZONTAL

MULLION FRAMING TO MATCH EXISTING

TO REMAIN INSTALLED MULLION AT W2,

SEE DETAIL 2/311 FOR MATERIALS TO

MATCH AND INSTALL

G.C. TO REMOVE EXISTING

INSTALLED PLYWOOD FACADE AND

INSPECTED EXISTING STEEL AND

WELD FOR DETERIORATION, NOTIFY

AOR OF ANY FINDINGS.

(SIMILAR)

DRAWING NAME:

DRAWING NUMBER:

DATE:

ISSUED FOR:

DRAWN BY:

REVIEWED BY:

PROJECT NUMBER:

It is a violation of New York Education Law Art. 145 Sec. 7209 & Art. 147 Sec. 7307, for any person, unless acting under the direction of a licensed architect, professional engineer, or land surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the alteration.

CERTIFICATE OF AUTHORIZATION NUMBER:

PROFESSIONAL ENGINEERING: 0021659

LAND SURVEYING: 0021272

GEOLOGICAL: 0021271

6/

/2

2:

:4

PM

A611

WINDOW SCHEDULE

JZ

MF

06/29/2026

BID

2261184

44 PIERREPONT AVE, POTSDAM, NY 13676

MAXCY HALL WINDOW

REPLACEMENT

SUNY POTSDAM

44 PIERREPONT AVE, POTSDAM, NY 13676

© 2020 LaBella Associates

22 Depot St., Suite 16 Potsdam, NY 13676

(315) 268-1338

A611

WINDOW "W1" DETAILED ELEVATION

SCALE: 1/2" = 1'-0"

A611

WINDOW "W2" DETAILED ELEVATION

SCALE: 1/2" = 1'-0"

A611

WINDOW "W3" DETAILED ELEVATION

SCALE: 1/2" = 1'-0"

1 Floor 0' - 0"

B. O. M.O. T. O. STEEL

23' - 4"

B. O. STEEL FRAMING

10' - 8"

FOUNDATION

-4' - 0"

A313

A313

A314

A313

A314

1' - 2"

8' - 10 3/4"

8'

- 1

0 3 /4"

A313

4 1 /2"

4 1 /2"

2'

- 4

3/ 4"

8'

- 1

0 3 /4"

G. C. TO CLEAN, REPAIR

DAMAGED WELDS AND PRIME

AND PAINT ALL EXISTING

STEEL

NEW HORIZONTAL SILLS

FIELD WELDED TO

EXISTING VERTICAL

MULLIONS. (TYP.)

G. C. TO CLEAN, REPAIR

DAMAGED WELDS AND PRIME

AND PAINT ALL EXISTING

STEEL

NEW 4" x 12" x 1/4" STEEL COLUMN AND BASE

FIELD WELDED TO EXISTING RIGID METAL

FRAMING

G.C. TO EXISTING ACM WINDOW CAULKING REMEDIATION TO

INCLUDE REMOVAL OF STOPS AND GLAZING. INSTALL NEW 3/4"

TEMPERED GLASS WITH SEALANT. REPLACE EXISTING PAINTED

STEEL 3/4" X 3/4" STOPS AS REQUIRED (TYP.)

4 1 /2"

3 1 /2"

EXISTING BRICK FACADE TO

REMAIN. PROTECT EXISTING

FINISH DURING CONTRACT

WORK (TYP.)

EXISTING BRICK FACADE TO

REMAIN. PROTECT EXISTING

FINISH DURING CONTRACT

WORK (TYP.)

8' - 10 3/4"

18' - 11 3/4" 29' - 0 1/4"

48' - 0"

8"

8"

EXISTING BRICK FACADE TO REMAIN. PROTECT EXISTING FINISH

DURING CONTRACT WORK (TYP.)

DRAWING NAME:

DRAWING NUMBER:

DATE:

ISSUED FOR:

DRAWN BY:

REVIEWED BY:

PROJECT NUMBER:

It is a violation of New York Education Law Art. 145 Sec. 7209 & Art. 147 Sec. 7307, for any person, unless acting under the direction of a licensed architect, professional engineer, or land surveyor, to alter an item in any way. If an item bearing the seal of an architect, engineer, or land surveyor is altered; the altering architect, engineer, or land surveyor shall affix to the item their seal and notation "altered by" followed by their signature and date of such alteration, and a specific description of the alteration.

CERTIFICATE OF AUTHORIZATION NUMBER:

PROFESSIONAL ENGINEERING: 0021659

LAND SURVEYING: 0021272

GEOLOGICAL: 0021271

6/

/2

2:

:5

PM

A612

WINDOW SCHEDULE

JZ

MF

06/29/2026

BID

2261184

44 PIERREPONT AVE, POTSDAM, NY 13676

MAXCY HALL WINDOW

REPLACEMENT

SUNY POTSDAM

44 PIERREPONT AVE, POTSDAM, NY 13676

© 2020 LaBella Associates

22 Depot St., Suite 16 Potsdam, NY 13676

(315) 268-1338

SCALE: 3/8" = 1'-0"A612

1 WINDOW "W4" DETAILED ELEVATION

G001 - ARCHITECTURAL COVER SHEET
A104 - PARTIAL THIRD FLOOR PLAN
A105 - WINDOWS PLAN
A201 - EXTERIOR ELEVATIONS
A202 - EXTERIOR ELEVATIONS
A203 - EXTERIOR ELEVATIONS
A311 - WALL SECTIONS AND DETAILS
A312 - WALL SECTIONS AND DETAILS
A313 - WALL SECTIONS AND DETAILS
A314 - WALL SECTIONS AND DETAILS
A611 - WINDOW SCHEDULE
A612 - WINDOW SCHEDULE

File details come from the government source that posted it. Updated .