Adden 2-Plan Sheets_DPH 451 Vanderbilt Floor Buildout.1644.pdf
PDF 5 MB Posted
- Attached to
- 1644 DPH 451 Vanderbilt 1st Floor Buildout
- Solicitation number
- ANE223-ANE2C-6410
- Issued by
- San Bernardino County, California
About this file
Addendum 2 Plan Sheets for DPH 451 Vanderbilt Floor Buildout
This document comprises architectural, engineering, and interior design plan sheets for a tenant improvement project at 451 East Vanderbilt Way, San Bernardino, California, prepared by LPA, Inc. for San Bernardino County Department of Public Health. The project involves comprehensive buildout of approximately 24,784 square feet on the first floor, including construction of new interior partitions, gypsum board ceilings, two new restrooms, and associated mechanical, electrical, and plumbing systems within an existing suite. The scope is limited to work within the suite boundaries, excluding site upgrades, building lobby, elevator lobby, and common area restrooms. The project is classified as occupancy type B, type III-1 hour construction, and must comply with the 2022 California Administrative Code, California Building Code, California Electrical Code, California Mechanical Code, California Plumbing Code, California Energy Code, California Fire Code, and California Existing Building Code. The documents include floor plans, demolition plans, finishes schedules, reflected ceiling plans, power and communication plans, plumbing and mechanical plans, electrical plans, door and equipment schedules, and detailed partition, ceiling, and millwork specifications. The city submittal is dated August 25, 2025, with Addendum A issued June 12, 2026, and a final addendum dated July 16, 2026. A mandatory pre-bid meeting was scheduled for June 9, 2026, with revised bid opening on August 14, 2026 at 2:00 p.m.
The project requires a State Contractor's Class B License and licensed subcontractors for mechanical (C-20), electrical (C-10), and plumbing (C-36) work. The construction estimate is $7.05 million with a contract duration of 160 calendar days from Notice to Proceed, subject to liquidated damages of $1,500 per day for delays. Bid security of 10 percent of the base bid and performance and labor/material bonds equal to 100 percent of the contract price are required. All work must comply with California prevailing wage requirements and CARB in-use off-road diesel fleet regulations, with all contractors and subcontractors required to register with the Department of Industrial Relations. Fire sprinkler and fire alarm drawings are deferred submissions to be provided by the general contractor post-award. The contractor bears responsibility for accurate construction placement, site safety, dust and noise control, debris removal, and coordination with structural observation. Specialized finishes include custom vinyl wall graphics, acoustical panels, quartz surfaces, luxury vinyl tile and plank, porcelain tile, glass film, and custom painted ceilings. Building systems include new suspended seismic ceiling grids, recessed and concealed fire sprinkler heads, new electrical panel connections, HVAC VAV units with controls, and complete plumbing with new fixtures in restrooms and support areas.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
ARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
LPADesignStudios.com
5301 California Avenue, Suite 100
Irvine, California 92617
PROJECT NUMBER
Submittal Date
CITY SUBMITTAL 08/25/2025
ADDENDUM A 06/12/2026
32468
DPH - FIRST FLOOR T.I.
451 E Vanderbilt Way, San Bernardino, CA 92408
G0.00
TITLE SHEET
Approved
Approved As Noted
Signature: Date:
COUNTY SUBMITTAL
08/25/2025
PC #TI-2025-00170
A
ADDENDUM A
06/12/2026
ADDENDUM A
06/12/2026
PCC-1
11/20/2025
ADDENDUM A
07/10/2026
COUNTY SUBMITTAL
07/10/20267/16/2026
COLUMN LINES
SURFACE DRAINAGE
ARROW INDICATES
DIRECTION OF FLOW
N
PROJECT NORTH
BUILDING SECTION
A101
TYP
SECTION ID
SHEET NUMBER
A101
TYP
WALL SECTION
SECTION ID
SHEET NUMBER
DETAIL CALLOUTS
DETAIL ID
SHEET NUMBER
A101
SIM
DETAIL SECTION
DETAIL ID
SHEET NUMBER
A101
SIM
DETAIL REFERENCE
DETAIL ID
SHEET NUMBER
A101
SIM
INTERIOR ELEVATIONS
DETAIL ID
SHEET NUMBER
A
C
SIM
D BA101
DOOR DESIGNATION
ROOM DESIGNATION
ROOM NUMBER
ROOM AREA
1REVISION CLOUD &
TAG (OPTIONAL)
SA2U
1t
SHADED PORTION POINTS
TO SIDE REFERENCED
DATUM POINT
KEYNOTE
WALL TYPE
OPENNING DESIGNATION
TYP.
MATCH LINE
SEE SHEET A101
LEVEL NAME
ELEVATION
LEVEL LINE, CONTROL POINT
EL: 12'-8" = ELEVATION/SECTION
STAIR DIRECTION
DN
UP
CENTER LINES, LEVEL LINES
HIDDEN CONSTRUCTION FEATURE
BREAK LINE
FINISH TAG
EQUIPMENT TAG 1i
N
TRUE NORTH
NORTH ARROW
EXTERIOR ASSEMBLY
REFER TO A8.11 R1
Room
150 SF
CAB CABINET
CB CATCH BASIN
CEM CEMENT
CER CERAMIC
CI CAST IRON
CIP CAST IN PLACE
CIV ENG CIVIL ENGINEER
CG CORNER GUARD
CJ CONTROL JOINT
CLG CEILING
CLKG CAULKING
CLO CLOSET
CLR CLEAR
CNTR COUNTER
CO CASED OPENING
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONSTR CONSTRUCTION
CONT CONTINUOUS
CORR CORRIDOR
CT CERAMIC TILE
CTR CENTER
CTSK COUNTERSUNK
DA DISABLED ACCESS
DBL DOUBLE
DEPT DEPARTMENT
DESC DESCRIPTION
DF DRINKING FOUNTAIN
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DISP DISPENSER
DN DOWN
DO DOOR OPENING
DR DOOR
DWR DRAWER
DS DOWNSPOUT
DSP DRY STANDPIPE
DWG DRAWING
E EAST
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
EP ELECTRICAL PANELBOARD
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXPO EXPOSED
EXP EXPANSION
EXT EXTERIOR
FA FIRE ALARM
FB FLAT BAR
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER
CABINET
FHC FIRE HOSE CABINET
FIN FINISH
FLR FLOOR
FLASH FLASHING
FLUOR FLUORESCENT
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FOV FACE OF VENEER (BRICK OR
PRECAST)
FOW FACE OF W ALL
FR FIRE RETARDANT
FPRF FIREPROOF
FS FINISH SURFACE
FT FOOT OR FEET
FTG FOOTING
FURR FURRING
FUT FUTURE
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GI GALVANIZED IRON
GL GLASS
GND GROUND
GR GRADE
GYP GYPSUM
HB HOSE BIB
HC HOLLOW CORE
HDWD HARDWOOD
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HGT/HT HEIGHT
ID INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
JAN JANITOR
JT JOINT
KIT KITCHEN
LAB LABORATORY
LAM LAMINATE
LAND ARCH LANDSCAPE
ARCHITECT
LAV LAVATORY
LKR LOCKER
LT LIGHT
MATL MATERIAL
MAX MAXIMUM
MC MEDICINE CABINET
MECH MECHANICAL
MEMB MEMBRANE
MET METAL
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MUL MULLION
N NORTH
NIC NOT IN CONTRACT
NO/# NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OA OVERALL
OA OUTSIDE AIR
OBS OBSCURE
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OPNG OPENING
OPP OPPOSITE
OSA OUTSIDE AIR
PA PLANTING AREA
PRCST PRECAST
PH PANIC HARDWARE
PL PLATE
P LAM PLASTIC LAMINATE
PLAS PLASTER
PLYW D PLYW OOD
POT PATH OF TRAVEL
PR PAIR
PT PAINT
PTD PAPER TOWEL
DISPENSER
PTD/R COMBINATION PAPER
TOWEL DISPENSER
& RECEPTACLE
PTN PARTITION
PTR PAPER TOWEL
RECEPTACLE
QT QUARRY TILE
R RISER
RAD RADIUS
RD ROOF DRAIN
REF REFERENCE
REFR REFRIGERATOR
RGTR REGISTER
REINF REINFORCED
REQD REQUIRED
RESIL RESILIENT
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
RWD REDWOOD
RWL RAIN WATER LEADER
S SOUTH
SC SOLID CORE
SCD SEAT COVER
DISPENSER
SCHED SCHEDULE
SD SOAP DISPENSER
SECT SECTION
SF SQUARE FEET
SH SHELF
SHR SHOW ER
SHT SHEET
SIM SIMILAR
SND SANITARY NAPKIN
DISPENSER
SNR SANITARY NAPKIN
RECEPTACLE
SPEC SPECIFICATION(S)
SQ SQUARE
SS STAINLESS STEEL
S SK SERVICE SINK
STA STATION
STD STANDARD
STL STEEL
STOR STORAGE
STR STRUCTURAL
SUSP SUSPENDED
SYM SYMMETRICAL
T TREAD
TB TOWEL BAR
TC TOP OF CURB
TEL TELEPHONE
TER TERRAZZO
T&G TONGUE & GROOVE
THK THICK
TOB TOP OF BEAM
TOC TOP OF CONCRETE
TOW TOP OF WALL
TOP TOP OF PARAPET
TPD TOILET PAPER
DISPENSER
TS TOP OF SLOPE
TV TELEVISION
TYP TYPICAL
UNF UNFINISHED
UNO UNLESS NOTED
OTHERWISE
UR URINAL
VCT VINYL COMPOSITION
TILE
VERT VERTICAL
VEST VESTIBULE
W WEST
W/ WITH
WC WATER CLOSET
WD WOOD
W/O WITHOUT
WP WATERPROOF
WR WATER RESISTANT
WSCT WAINSCOT
WT WEIGHT
WWF WELDED WIRE FABRIC
& AND
∠ ANGLE
@ AT
℄ CENTERLINE
∅ DIAMETER OR ROUND
# POUND OR NUMBER
(E) EXISTING
(P) PAINT
(R) REMOVE
+/- DIM TOLERANCE
AC ASPHALTIC CONCRETE
ACC ACCESSIBLE
ACOUS ACOUSTICAL
ACM ALUM COMPOSITE MATERIAL
ACT ACOUS CLG TILE
AD AREA DRAIN
AED AUTO EXT DEFIBRILLATOR
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
AGGR AGGREGATE
AHJ AUTHORITY HAVING
JURISDICTION
ALUM ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECTURAL
ASF ASSIGNABLE SF
ASPH ASPHALT
BD BOARD
BITUM BITUMINOUS
BLDG BUILDING
BLK BLOCK
BLK'G BLOCKING
BM BEAM
BOC BACK OF CURB
BOT BOTTOM
BO BOTTOM OF
BOC BACK OF CURB
BOW BOTTOM OF WALL
BS BOTTOM OF SLOPE
N
PROJECT NORTH
PROJECT LOCATION
ADDRESS:
451 E Vanderbilt Way, San Bernardino, CA 92408
N
TRUE NORTH
11B-201.4 CONSTRUCTION SUPPORT FACILITIES. These requirements shall apply to temporary or permanent construction support facilities for uses and activities not directly associated with the actual processes of construction, including but not limited to offices, meeting rooms, plan rooms, other administrative or support functions. When provided, toilet and bathing facilities serving construction support facilities shall comply with 11B-213. When toilet and bathing facilities serving construction support facilities are provided by portable units, at least one of each type shall be accessible and connected to the construction support facilities it serves by an accessible route.
EXCEPTION: During construction an accessible route shall not be required between site arrival points or the boundary of the area of construction and the entrance to the construction support facilities if the only means of access between them is a vehicular way not providing pedestrian access.
ACCESSIBLE CONSTRUCTION SUPPORT
FACILITIES
SEE "G" SERIES SHEETS FOR ACCESSIBLE REQUIREMENTS.
LPA, INC.
5301 CALIFORNIA AVE, SUITE 100
IRVINE, CA 92617
TEL: 949-261-XXXX
TEL: (909) 387-5000
DIRECTOR OF FACILITY
San Bernardino, CA 92408
ARCHITECT
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
CLIENT INFORMATION
PLUMBING ENGINEER
SAN BERNADINO COUNTY
TECHNOLOGY CONSULTANT
451 E Vanderbilt Way
CONTACT: LILIANA AUBERT E-MAIL: Liliana.Aubert@pfm.sbcounty.gov
CONTACT: SONALY DUDHEKER E-MAIL: sdudheker@lpadesignstudios.com
TEL: (323) 482-0720
LP CONSULTING ENGINEERS, INC.
3200 EAST GUASTI ROAD, SUITE 106
CONTACT: MIKE MORENO
E-MAIL:
mmoreno@lpengineers.com
LPA, INC.
5301 CALIFORNIA AVE, SUITE 100
IRVINE, CA 92617
TEL: 949-261-1001
CONTACT: JARED PLUMMER E-MAIL: jplummer@lpadesignstudios.com
LPA, INC.
5301 CALIFORNIA AVE, SUITE 100
IRVINE, CA 92617
TEL: 949-261-1001
CONTACT: MAUREN MCSHANE E-MAIL: mmcshane@lpadesignstudios.com
LPA, INC.
5301 CALIFORNIA AVE, SUITE 100
IRVINE, CA 92617
TEL: 949-261-1001
CONTACT: KRISTY NELSON E-MAIL: knelson@lpadesignstudios.com
ONTARIO, CA 91761
TENANT IMPROVEMENTS OF EXISTING SUITE TO INCLUDE CONSTRUCTION OF
NEW INTERIOR PARITIONS, AND CEILING PER LAYOUT AND RESTROOMS W ITHING
EXISTING SUITE. ASSOCIATED ELECTRICAL, MECHANICAL, AND PLUMBING
INCLUDED AS WELL.
SCOPE IS LIMITED TO WITHIN EXISTING SUITE. SITE UPGRADES, BUILDING LOBBY,
ELEVATOR LOBBY AND RESTROOMS IN THE LOBBY ARE NOT IN SCOPE.
1.FIRE SPRINKLER / FIRE ALARM - FIRE SPRINKLER DRAWINGS TO BE SUBMITTED
BY GENERAL CONTRACTOR ONCE AWARED.
1. ALL CONSTRUCTION & MATERIALS SHALL BE AS SPECIFIED & IN
ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES, LAWS, PERMITS
& THE CONTRACT DOCUMENTS.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE
PLACEMENT OF ALL NEW CONSTRUCTION ON THE SITE.
3. THE CONTRACTOR IS RESPONSIBLE FOR ALL EXG SURVEY MONUMENTS
WHICH MAY BE DISTURBED THROUGH CONSTRUCTION ACTIVITIES DEEMED
NECESSARY FOR PRESERVATION BY THE CIVIL ENGINEER. IF SUCH
MONUMENTS WERE DISTURBED, THE APPLICANT SHALL HAVE A LICENSED
LAND SURVEYOR QUALIFIED CIVIL ENGINEER REESTABLISH ANY SUCH
MONUMENTATION DAMAGED OR DESTROYED DURING THE CONSTRUCTION
OF THE PROJECT & SUBMIT "PRELIMINARY CORNER RECORDS" TO THE CIVIL
ENGINEER AFTER REPLACEMENT. AFTER APPROVAL BY THE CIVIL
ENGINEER, THE APPLICANT SHALL FILE THE CORNER RECORDS WITH THE
COUNTY SURVEYOR. PRIOR TO THE EXONERATION OF ANY SECURITY,
EVIDENCE OF SUCH FILING SHALL BE FURNISHED TO THE CIVIL ENGINEER.
4. THE CONTRACTOR IS RESPONSIBLE TO INSURE THAT TRUCK ROUTES
SHALL BE STEERED AWAY FROM RESIDENTIAL AREAS.
5. THE CONTRACTOR SHALL ENSURE THAT TRUCKS HAULING DIRT ON PUBLIC
ROADS TO & FROM THE SITE SHALL BE COVERED OR WILL MAINTAIN A 6"
DIFFERENTIAL BETWEEN THE MAX HGT OF ANY HAULED MATERIAL & THE
TOP OF THE HAUL TRAILER. HAUL TRUCK DRIVERS SHALL W ATER THE LOAD
PRIOR TO LEAVING THE SITE TO PREVENT SOIL LOSS DURING TRANSPORT.
6. THE CONTRACTOR SHALL ENSURE THAT GRADED SURFACES USED FOR
OFF ROAD PARKING, MATERIALS LAY-DOWN, OR AW AITING FUTURE
CONSTRUCTION SHALL BE STABILIZED FOR DUST CONTROL AS NEEDED.
FREQUENTLY ACCESSED UNPAVED AREAS SHALL BE PAVED AS EARLY AS
POSSIBLE TO MINIMIZE DIRT TRACKOUT TO PUBLIC RIGHTS-OF-WAY.
7. THE CONSTRACTOR SHALL COORDINATE ANY LANE CLOSURES OR
DETOURS WITH THE CITY/COUNTY. FLAG PERSONS & APPROPRIATE
TRAFFIC CONTROL DEVICES SHALL BE USED AS NEEDED TO MINIMIZE
CONSTRUCTION ACTIVITY INTERFERENCE WITH OFF-SITE-TRAFFIC.
8. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS & SITE CONDITIONS
BEFORE STARTING WORK. SHOULD A DISCREPANCY APPEAR IN THE
CONTRACT DOCUMENTS OR BETWEEN THE CONTRACT DOCUMENTS &
EXISTING CONDITIONS, NOTIFY THE ARCHITECT AT ONCE FOR INSTRUCTION
ON HOW TO PROCEED.
9. SHOULD A CONFLICT OCCUR BETWEEN DWGS & SPECIFICATIONS, THE
MORE COSTLY CONDITION SHALL TAKE PRECEDENCE, UNLESS A WRITTEN
DECISION FROM THE ARCHITECT HAS BEEN OBTAINED WHICH DESCRIBES A
CLARIFICATION OR ALTERNATE METHOD AND/OR MATERIALS.
10. THE CONTRACTOR SHALL CONFINE HIS OPERATION ON THE SITE TO AREAS
PERMITTED BY OW NER.
11. THE JOBSITE SHALL BE MAINTAINED IN A CLEAN, ORDERLY CONDITION FREE
OF DEBRIS & LITTER & SHALL NOT BE UNREASONABLY ENCUMBERED W ITH
ANY MATERIALS OR EQUIPMENT. EACH SUBCONTRACTOR IMMEDIATELY
UPON COMPLETION OF EACH PHASE OF HIS W ORK SHALL REMOVE ALL
TRASH & DEBRIS AS A RESULT OF HIS OPERATION.
12. ALL MATERIAL STORED ON THE SITE SHALL BE PROPERLY STACKED &
PROTECTED TO PREVENT DAMAGE & DETERIORATION. FAILURE TO
PROTECT MATERIALS MAY BE CAUSE FOR REJECTION OF WORK.
13. THE CONTRACTOR SHALL DO ALL CUTTING, FITTING, AND/OR PATCHING OF
HIS WORK THAT MAY BE REQ TO MAKE ITS SEVERAL PARTS FIT TOGETHER
PROPERLY & SHALL NOT ENDANGER ANY OTHER WORK BY CUTTING,
EXCAVATING, OR OTHERWISE ALTERING THE TOTAL WORK OR ANY PART OF
IT. ALL PATCHING, REPAIRING AND REPLACING OF MATERIALS AND
SURFACES, CUT OR DAMAGED IN EXECUTION OF WORK, SHALL BE DONE
WITH APPLICABLE MATERIALS SO THAT SURFACES REPLACED WILL, UPON
COMPLETION, MATCH SURROUNDING SIMILAR SURFACES.
14. STRUCTURAL OBSERVATION WILL BE PERFORMED BY THE STRUCTURAL
ENGINEER. W HEN REQ, A STATEMENT IN WRITING SHALL BE GIVEN TO THE
BUILDING OFFICIAL, STATING THAT THE SITE VISITS HAVE BEEN MADE &
WHETHER OR NOT ANY OBSERVED DEFICIENCIES HAVE BEEN CORRECTED
TO CONFORM TO THE APPROVED PLANS & SPECIFICATIONS.
15. SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITAL ITEMS SHALL BE
SUBMITTED TO THE ARCHITECT OR ENGINEER OF RECORD, WHO SHALL
REVIEW THEM & RETURN THEM TO THE CONTRACTOR (WITH A
NOTIFICATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS
HAVE BEEN REVIEWED & THAT THEY HAVE BEEN FOUND TO BE IN GENERAL
CONFORMANCE WITH THE DESIGN OF THE BUILDING) FOR PLAN CHECK
APPROVAL. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED
UNTIL THEIR DESIGN & SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY
THE AUTHORITY HAVING JURISDICTION.
16. PROVIDE ALL ACCESS PANELS AS REQ BY GOVERNING CODES TO ALL
CONCEALED SPACES, VOIDS, ATTICS, ETC. VERIFY TYPE REQ WITH
ARCHITECT PRIOR TO INSTALLATION.
17. NO PORTION OF W ORK REQ A SHOP DWG OR SAMPLE SUBMISSION SHALL
BE COMMENCED UNTIL THE SUBMISSION HAS BEEN REVIEWED BY THE
ARCHITECT. ALL SUCH PORTIONS OF THE WORK SHALL BE IN ACCORDANCE
WITH CORRECTED SHOP DWGS. AND SAMPLES.
18. DIMENSIONS:
A. ALL DIMS SHALL TAKE PRECEDENCE OVER SCALE.
B. ALL DIMS ARE TO FACE OF STUD / CONCRETE / MASONRY UNO
C. CLG HGT DIMS ARE FROM FACE OF SLAB TO FACE OF FIN CLG MATERIAL
UNO
19. DO NOT SCALE DRAW INGS
20. PROVIDE ALL NECESSARY BLOCKING, BACKING, & FRAMING FOR LIGHT
FIXTURES, ELECTRIC UNITS, AC EQUIP, RECESSED ITEMS, AND ALL OTHER
ITEMS AS REQ.
21. WHERE LARGER STUDS OR FURRING ARE REQ TO COVER PIPING AND
CONDUITS, THE LARGER STUD SIZE OR FURRING SHALL EXTEND THE FULL
SURFACE OF THE WALL WIDTH AND LENGTH WHERE THE FURRING
OCCURS, UNO.
22. ALL DOORS SHALL BE OPERABLE FROM THE INSIDE W/O THE USE OF A KEY
OR SPECIAL KNOWLEDGE OF EFFORT. EXIT SIGNS SHALL BE PROVIDED AT
ALL EXITS AS REQ BY THE APPLICABLE CODES. ALL DOOR SWINGS SERVING
AN OCCUPANT LOAD OF 50 OR GREATER SHALL SWING IN THE DIRECTION
OF TRAVEL.
23. ALL GLASS AND GLAZING SHALL COMPLY W ITH THE APPLICABLE CODES.
24. WALL AND CLG MATERIALS SHALL NOT EXCEED THE FLAME SPREAD
CLASSIFICATIONS IN THE APPLICABLE CODES.
25. SURVEYORS CERTIFICATE REQ PRIOR TO FINAL COMPLETION.
26. THE CONTRACTOR SHALL COMPLY WITH THE APPLICABLE CODES FOR FIRE
SAFETY DURING CONSTRUCTION AND DEMOLITION.
1. PLANS FOR THE FIRE SPRINKLER SYSTEMS MUST BE APPROVED BY THE
AUTHORITY HAVING JURISDICTION (AHJ) PRIOR TO INSTALLATION. SUBMIT
PLANS IN A MANNER WHICH W ILL NOT IMPEDE THE PROGRESS OF
CONSTRUCTION.
2. FIRE SPRINKLER SYSTEMS & INSTALLATION SHALL CONFORM W/ THE
APPLICABLE STANDARDS AND CODES.
3. FIRE SPRINKLER SYSTEMS TO BE TIED INTO THE ALARM SYSTEM PER THE
APPLICABLE CODES.
4. AUTOMATIC SPRINKLER SYSTEM(S) SHALL BE SUPERVISED BY AN APPROVED
CENTRAL OR REMOTE STATION SERVICE, AND/OR SHALL BE PROVIDED W/ A
LOCAL ALARM WHICH W ILL GIVE AN AUDIBLE SIGNAL.
5. FIRE SPRINKLER SYSTEM(S) & ALL CONTROL VALVES SHALL BE SUPERVISED
BY A U.L. LISTED CENTRAL ALARM STATION OR PER THE APPLICABLE CODES.
6. FIRE HYDRANT & FIRE SPRINKLER SYSTEM(S) SHALL BE FLUSHED
THOROUGHLY BEFORE CONNECTION IS MADE TO EXISTING SYSTEM
STUBOUTS & WITNESSED BY THE PROJECT INSPECTOR.
7. A HYDROSTATIC TEST (200 PSI PRESSURE FOR 2 HRS. OR @ 50 PSI IN
EXCESS OF THE MIN. STATIC PRESSURE WHEN IT IS IN EXCESS OF 150 PSI)
SHALL BE WITNESSED BY THE PROJECT INSPECTOR PRIOR TO COVERING
PIPING JOINTS.
8. A 3' CLR SPACE SHALL BE MAINTAINED AROUND THE CIRCUMFERENCE OF
FIRE HYDRANTS EXCEPT AS OTHERWISE REQ OR APPROVED PER THE
APPLICABLE CODES.
9. THRUST BLOCKS SHALL BE PROVIDED WHEREVER PIPE CHANGES
DIRECTION.
10. ALL PIPE SHALL BE UL LISTED FOR FIRE SERVICE SYSTEMS, CLASS 200 MIN.
11. FIRE DEPARTMENT CONNECTIONS SHALL BE LOCATED W /I 100' FROM A
PUBLIC FIRE HYDRANT PER THE APPLICABLE STANDARDS AND CODES.
12. FIRE SPRINKLER RISER SHALL BE LOCATED WITHIN 5 FT OF THE EXT WALL
(OR AS REQ BY THE AHJ) AND TERMINATE 6" ABV FF
13. AN ALL-WEATHER FIRE ACCESS ROAD SHALL BE IN PLACE BEFORE ANY
COMBUSTIBLE MATERIALS ARE PLACED ON THE SITE OR AS REQ BY THE AHJ.
14. STORAGE, DISPENSING, OR USE OF ANY FLAMMABLE & COMBUSTIBLE
LIQUIDS, FLAMMABLE & COMPRESSED GASES & OTHER HAZARDOUS
MATERIALS SHALL COMPLY W/ THE APPLICABLE CODES.
15. EXIT SIGNS SHALL BE POSTED OVER EXIT DOORS & DIRECTIONAL EXIT SIGNS
SHALL BE LOCATED TO DIRECT PERSONS TOWARD EXIT DOORS.
16. EXIT SIGNS SHALL BE SELF-LUMINOUS TYPE OR ELECTRONICALLY
ILLUMINATED & ENERGIZED FROM SEPARATE CIRCUITS, ONE OF WHICH
SHALL BE FROM STORAGE BATTERIES OR AN ON-SITE GENERATOR, FOR A
DURATION OF 90 MINUTES PER THE APPLICABLE CODES.
17. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A
KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT.
18. ACCESS GATE(S) SHALL BE OPENABLE W/ FIRE DEPT MASTER KEY FROM THE
EXTERIOR.
19. CURBS ALONG FIRE LANES SHALL BE PAINTED SAFETY RED & MARKED "FIRE
LANE NO PARKING" W/ 3" W HITE LETTERS ON THE TOP OF CURBING EVERY
30' AS INDICATED ON THE APPROVED DRAW INGS.
20. APPROVED NUMBERS OR ADDRESSES SHALL BE PROVIDED FOR ALL NEW &
EXG BLDGS IN SUCH A POSITION AS TO BE PLAINLY VISIBLE & LEGIBLE FROM
THE STREET OR ROAD FRONTING THE PROPERTY PER THE APPLICABLE
CODES.
21. PROVIDE PERMANENT OR TEMPORARY STANDPIPES WHILE BUILDING IS
UNDER CONSTRUCTION PER THE APPLICABLE CODES.
22. PROVIDE FIRE EXTINGUISHERS PER THE REQ THE APPLICABLE STANDARDS
AND CODES.
23. SPRINKLERS: ALL GYPSUM BOARD CEILINGS / SOFFITS AND
SPECIALTY CEILING TILE [SEE LEGEND], TO HAVE FULLY RECESSED
CONCEALED SPRINKLER HEADS WITH CAPS. ALL OTHER SPACES TO HAVE
STANDARD SPRINKLER HEADS PER INDICATED CEILING CONDITION, U.N.O.
24. SPRINKLERS: PROVIDE NEW AS REQUIRED BY REMODEL. DO NOT REUSE
SPRINKLER HEADS AT ALL LOCATIONS WHERE SPRINKLER/SPRINKLER PIPES
CONFLICT WITH NEW WORK. REMOVE, RELOCATE, AND/OR REPLACE
EXISTING SPRINKLER PIPING. NOTIFY ARCHITECT OF ANY FIELD CONFLICTS
PRIOR TO PROJECT BID.
25. SPRINKLERS: PROVIDE FULLY RECESSED CONCEALED SPRINKLER HEADS
WITH CAPS AT ALL SIDE WALL LOCATIONS.
2022 CALIFORNIA ADMINISTRATIVE CODE (CAC), PART 1, TITLE 24 CCR
2022 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24 CCR
2022 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 CCR
2022 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24 CCR
2022 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 CCR
2022 CALIFORNIA ENERGY CODE, PART 5 TITLE 24 CCR
2022 CALIFORNIA FIRE CODE (CFC), PART 9, TITLE 24 CCR
2022 CALIFORNIA EXISTING BUILDING CODE (CEBC), PART 10, TITLE 24 CCR
2022 CALIFORNIA GREEN BUILING STANDARDS CODE (CALGREEN), PART 11,
TITLE 24 CCR
2022 CALIFORNIA REFERENCED STANDARDS CODE, PART 12, TITLE 24 CCR
TITLE 19 CCR, PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS
CURRENT CITY OF SAN BERNARDINO REGULATIONS AND ORDINANCES
APPLICABLE STANDARDS
FOR A LIST OF APPLICABLE STANDARDS, INCLUDING CALIFORNIA AMENDMENTS
TO THE NFPA STANDARDS, REFER TO CBC CHAPTER 35 AND CFC CHAPTER 80.
PROJECT LOCATION: 351 E VANDERBILT WAY,
SAN BERNARDINO, CA 92408
BUILDING OCCUPANCY: B
TYPE OF CONSTRUCTION: III - 1 HOUR
NUMBER OF STORIES: 4
AS-BUILT TOTAL BUILDING AREA: 120,538 SF
AREA OF SCOPE (FIRST FLOOR): 24,784 SF
R e v is io n
D a te
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
ARCHITECTURE ENGINEERING INTERIOR DESIGN
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
LPADesignStudios.com
5301 California Avenue, Suite 100
Irvine, California 92617
D e v e lo p e d f o r
Checked By
Scale
Job Number
S u b m it ta l D a te
C
IT
Y S
U B
M
IT
T A
L
/2
/2
This document and all other project documents, ideas, aesthetics and designs incorporated therein are instruments of service. All project documents are copyright protected, are the property of LPA, Inc. (LPA) and cannot be lawfully used in whole or in part for any project or purpose except as set forth in the contractual agreement between LPA and its Client. The unauthorized disclosure and/or use of the project documents (including the creation of derivative works), may give rise to liability for copyright infringement, unlawful disclosure, use or misappropriation of property rights held by LPA. The unauthorized use of the project documents will give rise to the recovery of monetary losses and damages including attorney fees and costs for which the unauthorized user will be held liable.
Project documents describe the design intent of the work and are not a representation of as-built or existing conditions. LPA is not responsible for any discrepancies between the project documents and the existing conditions.
© LPA, Inc.
As indicated
E
V a n d e rb ilt W a y
S a n B e rn a rd in o
C
A
S A
N B
E R
N A
R D
IN
O
C O
U N
T Y
D P
H
F
IR
S T
F L
O O
R T
.I
S A
N B
E R
N A
R D
IN
O
C O
U N
T Y
E
V a n d e rb ilt W a y
S a n B e rn a rd in o
C
A
GENERAL INFORMATION
SHEET
G0.20
32468
SD/NF/KR
SHEET INDEX
S H
E E
T N
U M
B E
R
SHEET NAME
GENERAL
G0.00 TITLE SHEET
G0.20 GENERAL INFORMATION SHEET
G0.21 GENERAL CONDITIONS & NOTES
G0.22 GENERAL CONDITIONS & NOTES
G0.31 ACCESSIBILITY DETAILS
G0.32 ACCESSIBILITY DETAILS
G0.40 CAL GREEN (CA)
G0.41 CAL GREEN (CA)
G0.42 CAL GREEN (CA)
G0.43 CAL GREEN (CA)
G2.01 01 - FLOOR - CODE ANALYSIS
ARCHITECTURE
A1.01 01 - FLOOR DEMO PLAN
A2.01 01 - FLOOR FLOOR PLAN
A2.21 01 - FLOOR FINISHES PLAN
A2.31 01 - FLOOR REFLECTED CEILING PLAN
A2.41 01 - FLOOR POWER & COMMUNICATION
A4.01 ENLARGED RESTROOM PLANS
A5.01 ENLARGED PLANS AND INTERIOR ELEVATIONS
A5.02 ENLARGED PLANS AND INTERIOR ELEVATIONS
A5.03 INTERIOR ELEVATIONS
A5.04 INTERIOR ELEVATIONS
A5.05 INTERIOR ELEVATIONS
A6.00 DOOR TYPES & SCHEDULES
A6.31 SCHEDULES
A9.01 PARTITION DETAILS
A9.10 TYPICAL LIGHT GAUGE METAL STUD DETAIL
A9.11 INTERIOR DETAILS
A9.12 INTERIOR DETAILS
A9.13 DOOR DETAILS
A9.21 CEILING DETAILS
A9.22 CEILING DETAILS
A9.31 MILLWORK DETAILS
A9.32 MILLWORK DETAILS
A9.41 RESTROOM DETAILS
SYMBOLSABBREVIATIONS
VICINITY MAP
ACCESSIBILITY NOTES PROJECT SCOPE
T8.3 RATED ASSEMBLY PENETRATION
T8.2 AUDIO-VIDEO DETAILS
T8.1 TECHNOLOGY DETAILS
T4.1 TECHNOLOGY ONE-LINE DIAGRAM
T2.2 TECHNOLOGY FIRST FLOOR CEILING PLAN
T2.1 TECHNOLOGY FIRST FLOOR PLAN
T0.2 TECHNOLOGY LEGENDS
T0.1 TECHNOLOGY NOTES
TECHNOLOGY
E9.01 LIGHTING PHOTOMETICS PLAN
E8.01 ENERGY COMPLIANCE FORMS
E7.02 LIGHTING DETAILS
E7.01 ELECTRICAL DETAILS
E6.10 ELECTRICAL FIXTURE SCHEDULE
E6.03 ELECTRICAL MECHANICAL SCHEDULES
E6.02 ELECTRICAL PANEL SCHEDULES
E6.01 ELECTRICAL SINGLE LINE DIAGRAM AND PANEL SCHEDULES
E5.13 LIGHTING CONTROL BUTTON ENGRAVING DIAGRAMS
E5.12 LIGHTING CONTROL DIAGRAMS
E5.11 LIGHTING CONTROL DIAGRAMS
E5.10 LIGHTING FIXTURE & CONTROL NOTES
E2.21 LIGHTING PLAN
E2.11 ELECTRICAL POWER/MECH PLAN
E2.01 ELECTRICAL POWER PLAN
E1.01 ELECTRICAL DEMOLITION PLAN
E0.04 ELECTRICAL SPECIFICATIONS
E0.03 ELECTRICAL SPECIFICATIONS
E0.02 ELECTRICAL LEAD SHEET
E0.01 ELECTRICAL LEGEND & GENERAL NOTES
ELECTRICAL
P9.01 PLUMBING SPECIFICATIONS
P7.01 PLUMBING DETAILS
P6.01 PLUMBING SCHEDULES
P4.01 PLUMBING ENLARGED PLANS
P3.01 PLUMBING DOMESTIC WATER & GAS PLANS
P2.01 PLUMBING DRAINAGE PLANS
P1.01 PLUMBING DEMOLITION PLANS
P0.10 PLUMBING LEGEND & GENERAL NOTES
PLUMBING
M9.01 MECHANICAL SPECIFICATIONS
M8.04 MECHANICAL ENERGY COMPLIANCE DOCUMENTATION
M8.03 MECHANICAL ENERGY COMPLIANCE DOCUMENTATION
M8.02 MECHANICAL ENERGY COMPLIANCE DOCUMENTATION
M8.01 MECHANICAL ENERGY COMPLIANCE DOCUMENTATION
M7.01 MECHANICAL DETAILS
M6.01 MECHANICAL SCHEDULES
M5.10 MECHANICAL CONTROL DIAGRAMS
M5.01 MECHANICAL ZONING PLANS
M2.11 MECHANICAL PIPING & CONTROLS PLANS
M2.01 MECHANICAL HVAC PLANS
M1.01 MECHANICAL DEMOLITION PLANS
M0.01 MECHANICAL LEGEND & GENERAL NOTES
MECHANICAL
DEFERRED APPROVALS
CONSTRUCTION NOTES
FIRE AND LIFE SAFETY NOTES
APPLICABLE CODES
PROJECT INFORMATION
A A d d e n d u m
A
/1 /2
A
A
A
A
A
7/
/2
REF. REF. REF. REF.MWMW
CMCM
WDS
T V
WDS
C R
CR
C R
CR
CR
CR
CR
TVTV
TV
TV
T V
T V
T V
TV
TV
TV
P R
IN
T
P R
IN
T
U C R
TV
TV
CR
CR
CR
FR
ZR
P R
IN
T
W D
S C
M
CM?
F E
C
FEC
FEC
F E
C
FEC
FEC
CR
FEC
FEC
ALIGN
A L
IG
N
A L
IG
N
A L
IG
N
ALIGN
A L
IG
N
A L
IG
N
A L
IG
N
A L
IG
N
A L
IG
N
ALIGN
FEC
C R
ALIGN
PARTITION LEGEND
1. REFER TO DETAILS ON "G" SHEETS FOR ACCESSIBLE REQUIREMENTS ON
PLAN DIMENSIONS AND DOOR REQUIREMENTS. DIMENSIONS THAT ARE NOT
STATED AS "MINIMUM" OR "MAXIMUM" ARE ABSOLUTE.
2. REFER TO SPECIFICATIONS ON "G" SHEETS FOR MATERIAL PERFORMANCE
AND EXECUTION OF WORK.
3. JOB SITE SAFETY: THESE PLANS AND SPECIFICATIONS DO NOT PROVIDE ANY
DIRECTION OR INSTRUCTIONS TO THE CONTRACTOR OR SUBCONTRACTORS
OR THEIR EMPLOYEES OR AGENTS RELATED TO CONSTRUCTION MEANS,
METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY
PRECAUTIONS INCLUDING JOB SITE SAFETY AND PROGRAMS IN CONNECTION
WITH THE WORK. THIS IS SOLELY THE CONTRACTOR'S RESPONSIBILITY
UNDER THE CONTRACTOR'S CONTRACT FOR CONSTRUCTION. THE
ARCHITECT HAS NOT CONDUCTED AN EVALUATION OF SAFETY PROCEDURES
FOR THE PROPER MANNER OF ACCESSING THE JOB SITE DURING THE
COURSE OF CONSTRUCTION AND HAS NOT UNDERTAKEN ANY
RESPONSIBILITY ON W HETHER OR NOT THE USE OF ROOF/ OR
CONSTRUCTION LADDERS, DOORS, RAILINGS, INGRESS AND INGRESS
ROUTES OR THE LIKE ARE IN COMPLIANCE WITH OSHA REQUIREMENTS
DURING THE COURSE OF CONSTRUCTION OF THE IMPROVEMENTS.
4. FRAMING: DOOR OPENING IN PARTITION NOT DIMENSIONED ARE TO BE
LOCATED W ITHIN 4" OF PERPENDICULAR/ADJOINING PARTITION.
5. FLOOR PREPARATION: PATCH AND REPAIR OPENINGS AT FLOOR WHERE
ABANDONED CONDUITS, FLOOR CORES, ETC. HAVE BEEN REMOVED. SEE
DETAIL 09/A9.11.
6. DRYWALL: PATCH AND REPAIR WALLS TO REMAIN WHERE CUT INTO FOR
NEW CONSTRUCTION AND/OR WHERE DEVICES/EQUIPMENT HAVE BEEN
REMOVED. MAINTAIN RATINGS W HERE OCCUR. PREPARE DRYWALL TO
RECEIVE NEW FINISHES.
7. DRYWALL FINISH: MAINTAIN LEVEL FOUR (4) QUALITY AT ALL WALLS
INCLUDING EXISTING, RESKIM AS REQUIRED FOR A CONSISTENT FINISH.
8. DOORS: FIELD VERIFY ALL WALL THICKNESS FOR THROAT DIMENSIONS PRIOR
TO ORDERING DOOR FRAMES.
9. EXISTING DOORS TO REMAIN: SEE DOOR SCHEDULE FOR SPECIFIC SCOPE.
10. SAW CUTTING: ALLOW FOR STANDARDIZED SAW CUTTING AT SLAB FOR
PLUMBING AND ELECTRICAL IF REQUIRED BY PLAN. SEE FLOOR PLAN FOR
LOCATIONS. REFER TO ELECTRICAL AND PLUMBING FOR MORE INFORMATION.
SEE DETAIL
11. FLOOR PREPARATION: PERFORM MOISTURE AND ALKALINITY (PH) FLOORING
TEST THROUGHOUT AND REPORT FINDINGS AND MITIGATION METHOD
OPTIONS TO ARCHITECT/LANDLORD/CLIENT, PRIOR TO ORDERING/
INSTALLATION OF MATERIALS. SEE SPECIFICATION SECTION 090561.
12. BACKING: PROVIDE AS REQ, SEE EQUIPMENT LEGEND. PROVIDE 6" X 20 GA.
BACKING IN WALL TO SUPPORT COUNTY PROVIDED TV SCREEN, SEE
EQUIPMENT SCHEDULE / POWER & COMM PLAN FOR LOCATIONS, G.C.C TO
COORDINATE LOCATION AND MOUNTAIN HEIGHT WITH AV VENDOR. SEE
DETAIL
13. PARTITION: GENERAL CONTRACTOR TO FIELD VERIFY ALL WALL THICKNESS
FOR THROAT DIMENSIONS FOR DOOR FRAMS & STUD SIZES.
14. HARDWARE: GENERAL CONTRACTOR TO VERIFY THAT ALL DOOR HARDWARE
TYPE IS CONSISTENT THROUGHOUT PROJECT. REPLACE ALL NON-MATCHING
HARDWARE WITH BUILDING STANDARD SPECIFICATION. SEE DOOR
SCHEDULE.
15. OPERABLE PART OF BUILT IN COFFEE MAKER OR BUILDING IN MICROWAVE
SHALL COMPLY WITH SECTION 11B-309. (CBC 11B-205)
A. CLEAR FLOOR SPACE OF 30"X48" FOR FORW ARD OR PARALLEL
APPROACH. (CBC 11B-305)
B. OPERABLE PART SHALL BE PLACED WITHIN ONE OR MORE OF THE REACH
RANGES SPECIFIED IN SECTION 11B-308.
C. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT
REQUIRE TIGHT GRSPING, PINCHING OR TWISTING OF THE WRIST.
/09 A9.11
/10 A9.11
A A.3 A.7 B C D E.2 E.5 HD.2C.7 E F G
1.7
1.3
3.7
4.2
4.8
6.3
(E)
MENS
RESTROOM
(E)
WOMENS
RESTROOM
(E) ELEV
MACHINE
RM
(E) TELE
(E) ELEC
(E)
BLDG
STORAGE
(E)
BLDG
STORAGE
(E) ELEC
(E) TELE
(E) MAIL
ROOM
MAIN
ENTRY
(E)
JANITOR
(E) MAIN
ELEC
ROOM
NIC
NIC
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
BREAKROOM
BOARDROOM
CONSULT
PRIVATE
OFFICE
VITAL
STATS
ENTRY
RESTROOM
RESTROOM
IDF
MENS
RESTROOM
WOMENS
RESTROOM
PLAN
CHECK
WORKSTATIONS
OPEN
OFFICE
OPEN
OFFICE
COPY /
OPEN
OFFICE
OPEN
OFFICE
CONFERENCE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
144PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
MEDIA
ROOM
CONSULT
VITAL
STATS
STORAGE
OPEN
OFFICE
OPEN
OFFICE
BIRTH/DEATH
CERT.
STORAGE
WELLNESS
WATER
SPECIMEN
STORAGE
PLAN
STORAGE
EMERGENCY
SUPPLIES,
PPE
OPEN
OFFICE
COPY
EHS
ENTRY
KIOSKS
RECEPTION
RECEPTION
COPY/
HALLWAY
HALLWAY
105A
171 105B
101B
129B
156B
102B102C
JANITOR
(E) 1HR
RATED
STAIRS
#2
(E) 1HR
RATED
STAIRS
#1
'-7
HALLWAY
ALCOVE
4' -6
'-1
5' -6
12'-0"
TYP.
4'-0"
TYP.
09.01
TYP.
09.01
TYP.
09.01
TYP.
09.01
TYP.
09.01
TYP.
09.01
TYP.
09.01
TYP.
09.01
TYP.
09.01
TYP.
09.01
TYP.
09.01
136137138139140141142143144145146147148149150
PLAN
CHECK
COUNTER
102A
101A
(E)163
(E)128
(E)161
09.03
09.03
09.03
09.03 09.03 09.03
09.01
(E)171
(E)172 (E)174
(E)173
(E)170 (E)167(E)168
(E)169
(E)167
TYP.
09.02
09.04
09.04
09.04
09.04
09.04
A5.03 20
A5.03
A5.04
A5.0401
A5.03
A5.0316
A5.04
A5.03
A5.03
A5.03
A5.03
A5.0410
A4.01
A4.01
A5.01
SA3I
SA3I
SA3I
SA3I
SA3I
SA3I
SA3I
SA3I
SA3I
SA3I
SA3I
SA3I
SA3I
SA3I
SA3I
SA4I
SA3I
SA3I
SA3I
SA3I
SA3I
SA3I
SA3I
SA3I
SA3I
SD3I
SA3I
SA3I
SA3I
SA3I
SA3I
SA3ISA3ISA3ISA3ISA3ISA3I
SA3I
SD3I
SA3I
SA3I
SA3I
SA3I
SA3I
SA3I
SC2
SA3I
'-6
13'-2"
E Q
E Q
3'-2"
2'-1"
2'-11"
5'-11"
EQ
.0
45.00°
'-1
1"
135.00°
CLR.
6'-3"
.0
'-1
0"
1'-8"
14'-5"
15'-1"
19'-6"
5'-5" 10'-5"
6'-6"
'-5
'-7
SG2
SG3I
1'-0"
A5.0317
EQEQ
EQEQEQ EQ
EQ EQ EQ
E Q
E Q
SA4I
SA4I
SA6 SA6
TYP.
02.73
TYP.
02.73
TYP.
02.73
TYP.
07.01
TYP.
07.01
TYP.
07.01
TYP.
09.02
SA3I
SE3ISE3I
SD3I
SE3I
SA3I
SA6
21.08
A5.04
SL6I
SL6I
SA3I
SA3I
SC2
A5.05
A5.05 02
A5.05
A5.0504
A5.05
A5.05
A5.05
A5.05A5.05 22
A5.05
A5.05
A5.05 A5.051523
A5.05
A5.0513
A5.05
A5.0512
A9.11
TYP.
SD3I
SA3I
SD3I SA3I
SD3I
SD3I
SD3I
SE3ISE3I
SD2
SC3
SA3I
A9.11
TYP.
SG3I
SA3I
SA3I
2'-11"
11"
12'-0"1
13'-3"
SC3SC3
08.18
08.18
TYP.
09.16
3'-3"
A9.11
5 1/2"
6'-4"
SE3ISE3I
26'-2"
08.19
SA3I
SA3I
SA3I
SA3I
SG2
SA4I
SA3I
SC3
A5.02
T Y
P
U .N
.O
31'-8"
±18'-5"
TYP. U.N.O.
9'-7"
3'-3"
17'-5"
7'-8"
36'-3"
7' -0
135.00°
8'-0"
.0
45.00°
12'-2"
9'-8"
08.22
08.22
08.22
08.22
08.22
08.22
08.22
08.22
08.22
18'-10"
6'-1"
A5.02 22
SD3I
SA3ISA3I
SD2
SA3I
SA4I
SH6I
SA3ISA3I
02.23 14'-10"
5'-7"
'-1
1"
10'-3"
'-5
A
A
A
A
'-5
'-9
9'-8"
A
A
A
5'-8"
A
A
A
NEW SINK - SEE PLUMBING
PROVIDE NEW WALL MOUNTED FIRE EXTINGUISHER
CABINET TO MATCH EXISTING WALL MOUNTED. G.C. TO
FURNISH AND INSTALL NEW EXTINGUISHER. SEE DETAIL
ALIGN FINISHES
DENOTES DOOR NUMBER - REFER TO DOOR SCHEDULE /
DOOR TYPES, SHEET A6.00
DOOR: SEE DOOR LEGEND SHEET A6.00
1/4" WATERLINE - SEE PLUMBING
HATCHED AREA INDICATES EXISTING SPACE TO REMAIN AND
NOT BE INCLUDED IN THIS SCOPE OF WORK
DENOTES NEW MILLWORK, SEE ENLARGED PLANS AND
ELEVATIONS. SEE SHEETS A9.31 & A9.32 FOR DETAILS
NEW CARD READER LOCATION. SEE POWER / COMM
LEGEND FOR SCOPE
NEW STUD WALL CONSTRUCTION, SEE SHEET A9.01
1 HOUR RATED FIRE BARRIER W ALL CONSTRUCTION
EXISTING STUD WALL CONSTRUCTION
SA2U
WALL TYPE. LETTER INDICATES WALL TYPE. SEE WALL TYPE
DETAIL.
INSULATION TYPE. I = BATT INSULATION, U = NO BATT
INSULATION, Q = BATT INSULATION WITH INSUL-QUILT ABOVE
NOTE:
SEE SHEET A9.01 FOR ALL WALL TYPE DETAILS. UNLESS OTHERWISE NOTED,
ALL INTERIOR PARTITIONS INCLUDE ROCK WOOL INSULATION FULL HEIGHT
OF STUDS
STUD TYPE. S = STEEL, W = WOOD
STUD SIZE. NUMBER INDICATES STUD SIZE. SEE WALL TYPE
DETAIL. REFER TO A9.01 FOR INTERIOR STUD WALL SCHEDULE
WALL TAG:
2 HOUR RATED FIRE BARRIER W ALL CONSTRUCTION
/01 A9.11
4x8 FIRE TREATED PLYWOOD BACKBOARD, INSTALL
FROM 12'' AFF. VERIFY INSTALL LOCATIONS WITH
CLIENT. PAINT TO MATCH WALL. DO NOT PAINT OVER
RATING LABEL.
R e v is io n
D a te
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
ARCHITECTURE ENGINEERING INTERIOR DESIGN
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
LPADesignStudios.com
5301 California Avenue, Suite 100
Irvine, California 92617
D e v e lo p e d f o r
Checked By
Scale
Job Number
S u b m it ta l D a te
C
IT
Y S
U B
M
IT
T A
L
/2
/2
This document and all other project documents, ideas, aesthetics and designs incorporated therein are instruments of service. All project documents are copyright protected, are the property of LPA, Inc. (LPA) and cannot be lawfully used in whole or in part for any project or purpose except as set forth in the contractual agreement between LPA and its Client. The unauthorized disclosure and/or use of the project documents (including the creation of derivative works), may give rise to liability for copyright infringement, unlawful disclosure, use or misappropriation of property rights held by LPA. The unauthorized use of the project documents will give rise to the recovery of monetary losses and damages including attorney fees and costs for which the unauthorized user will be held liable.
Project documents describe the design intent of the work and are not a representation of as-built or existing conditions. LPA is not responsible for any discrepancies between the project documents and the existing conditions.
© LPA, Inc.
1/8" = 1'-0"
E
V a n d e rb ilt W a y
S a n B e rn a rd in o
C
A
S A
N B
E R
N A
R D
IN
O
C O
U N
T Y
D P
H
F
IR
S T
F L
O O
R T
.I
S A
N B
E R
N A
R D
IN
O
C O
U N
T Y
E
V a n d e rb ilt W a y
S a n B e rn a rd in o
C
A
01 - FLOOR FLOOR PLAN
A2.01
32468
SD/NF/KR
1/8" = 1'-0"
A2.01 1FLOOR PRICING PLAN
KEYNOTES
02.23 SEE PLUMBING FOR EXISTING PIPE LOCATION. PIPE TO REMAIN IN
PLACE. FURR AROUND EXISTING COLUMN AND PIPE.
02.73 EXISTING DRYWALL BASE FINISH: PROVIDE SKIM COAT WHERE
EXISTING 4" BASE WAS REMOVED AND NEW 4" BASE IS BEING
UTILIZED.
07.01 INSULATION: BELOW SINKS, PROVIDE INSULATION ON ANY
EXPOSED DRAIN OR WATER SUPPLY PIPES AND THERE SHALL BE
NO SHARP OR ABRASIVE SURFACES. (CBC 2002 11B - 606.5)
08.18 GENERAL CONTRACTOR TO VERIFY THAT CORING EXISTS AT RATED
DOOR TO RECEIVE SECURITY DEVICE BY CUSTOMER. IF NOT, CORE
AND RE-CERTIFY DOORS OR PROVIDE NEW. MAINTAIN RATING.
08.19 EXTERIOR WINDOW FILM: PROVIDE BLACK OUT WINDOW FILM AT
THIS WINDOW ONLY.
08.22 WINDOW COVERINGS: PROVIDE MARIAK CONTRACT DUEL FULL
HEIGHT MANUAL ROLLER SHADES WITH 3% OPENNESS AND BLACK
OUT. ROLLER SHADE TO BE MOUNTED INSIDE THE EXISTING
MULLION, FASCIA COLOR TO MATCH EXISTING MULLION. SHADE
COLOR: TBD
09.01 PROVIDE BACKING FOR TV MONITORS, SEE AUDIO VISUAL
DRAWINGS FOR LOCATIONS, SIZES AND WEIGHTS.
09.02 PROVIDE GWB / MTL FRAMING TO 6" ABOVE CEILING SURROUNDING
ALL COLUMNS.
09.03 G.C TO PROVIDE BACKING FOR CLIENT PROVIDED WHITE BOARD.
SEE DETAIL 10/A9.11
09.04 G.C TO PROVIDE BACKING FOR SHELVING. SEE DETAIL 10/A9.11
09.16 WALL TO BE CENTERED ON THE MULLION.
21.08 EXISTING RELOCATED FIRE EXTINGUISHER CABINET.
FLOOR PLAN GENERAL NOTES
N
PROJECT NORTH
A A d d e n d u m
A
/1 /2
A
A A
A
CMCM
WDS
T V
WDS
C R
CR
C R
CR
CR
CR
CR
TVTV
TV
TV
T V
T V
T V
TV
TV
TV
P R
IN
T
P R
IN
T
U C R
TV
TV
CR
CR
CR
P R
IN
T
W D
S C
M
CM?
F E
C
FEC
FEC
F E
C
FEC
FEC
CR
FEC
FEC
A L
IG
N
FINISH SYMBOL
FINISH CODE - SEE FINISH SCHEDULE
INSTALL DIRECTION OF FLOORING MATERIAL
FLOOR FINISH TRANSITION:
SEE DETAIL
TRANSTIONS:
• PROVIDE STAINLESS STEEL SCHLUTER STRIP EDGE TRANSITION
AT TRANSITIONS 1/4" CHANGE IN ELEVATION OR LESS.
• PROVIDE STAINLESS STEEL SCHLUTER RENO-U TRANSITION AT
TRANSITIONS GREATER THAN 1/4" UP TO 1/2".
• FOR TRANSITIONS GREATNER THAN 1/2", PROVIDE SCHUTER
SCHENE EDGE TRIM AND RAMP UP AT POLISHED CONCRETE.
/17 A9.11
1. REFER TO SPECIFICATIONS "G SERIES " FOR FINISH MATERIAL PERFORMANCE AND
EXECUTION OF WORK.
2. FLOOR PREPARATION: PERFORM MOISTURE AND ALKALINITY (PH) FLOORING TEST
THROUGHOUT AND REPORT FINDINGS AND MITIGATION METHOD OPTIONS TO
ARCHITECT/LANDLORD/CLIENT, PRIOR TO ORDERING/INSTALLATION OF MATERIALS.
SEE SPECIFICATION SECTION 090561.
3. TILE APPLICATION: SEAL ALL FLOOR AND WALL GROUT AROUND PLUMBING AND WET
AREAS. MIN. PER MANUFACTURER RECOMMENDATION. COORDINATE AS REQUIRED
FOR GROUT JOINT ALIGNMENT.
4. TILE APPLICATION: LAY TILE ACCORDING TO PATTERN INDICATED ON CONSTRUCTION
DOCUMENTS. IF THERE IS A CONFLICT WITH THE MANUFACTURER'S
RECOMMENDATIONS, THE MANUFACTURER'S RECOMMENDATIONS WILL GOVERN THE
INSTALLATION METHOD. LARGE FORMAT TILES [ANY TILE WITH AN EDGE DIMENSION
EQUAL OR GREATER THAN 15"] W ILL HAVE A 30% OFFSET AS OPPOSED TO A 50%
OFFSET. VERIFY TILE TO TILE JOINT RELATIONSHIP W ITH MANUFACTURER TO AVOID
"LIPPAGE". DO NOT INTERRUPT TILE PATTERN THROUGH OPENINGS.
5. FLOOR: CONTINUE FLOOR FINISH UNDER/INTO ACCESSIBLE SINK LOWER CABINET.
6. FLOOR: PROVIDE 'FEATHER UP' TRANSITION AT ALL DOORS WHEN THERE IS A
DIFFERENCE OF 1/ 4" OR MORE TO MEET ACCESSIBLE REQUIREMENTS AT A MINIMUM.
7. MATERIAL DIRECTIONAL INSTALLATION: IF INSTALLATION DIRECTION IS NOT
INDICATED ON PLANS, CONTACT ARCHITECT FOR CLARIFICATION PRIOR TO
INSTALLATION. CONTRACTOR TO PROVIDE ON-SITE TILE MOCK-UP FOR ALL AREAS
RECEIVING TILE. MOCK-UP TO BE REVIEW ED W ITH ARCHITECT TO CONFIRM GROUT
LAYOUT, INCLUDING START AND STOP POINTS, AND TO AVOID TILE SLIVERS.
CONTRACTOR SHALL PROVIDE A MINIMUM OF 48 HR NOTICE FOR MEETING.
8. ACCESS PANEL: PAINT TO MATCH ADJACENT WALL/SOFFIT COLOR, WHERE OCCURS
OR UNLESS SPECIFIED AS A PREFINISHED MATERIAL SUCH AS STAINLESS STEEL.
9. CIRCULATION PATHS OF THE MEANS OF EGRESS SHALL HAVE A SLIP-RESISTANT
SURFACE AND BE SECURELY ATTACHED. (2022 CBC 1003.4)
10. FLOOR AND GROUND SURFACES SHALL BE STABLE, FIRM, AND SLIP RESISTANT. (2022
CBC 11B-302)
11. CARPET SHALL BE SECURELY ATTACHED AND SHALL HAVE A FIRM CUSHION, PAD, OR
BACKING, OR NO PAD. IT SHALL HAVE A LEVEL LOOP, TEXTURED LOOP, LEVEL CUT, OR
LEVEL CUT/UNCUT PILE TEXTURE. PILE HEIGHT SHALL BE 1 /2 '" MAXIMUM. EXPOSED
EDGES SHALL BE FASTENED TO FLOOR SURFACES AND SHALL HAVE A TRIM ON THE
ENTIRE LENGTH OF THE EXPOSED EDGE. (2022 CBC 11B-302.2)
12. TRANSITIONS OF MATERIALS AND EDGES OF CARPET SHALL COMPLY WITH CHANGES
IN LEVEL. (2022 CBC 11B-303)
13. INTERIOR FINISH MATERIALS APPLIED TO WALLS AND CEILINGS SHALL MEET THE FIRE
PERFORMANCE AND SMOKE DEVELOPMENT LIMITATIONS PRESCRIBED IN CBC
SECTION 803, INCLUDING "CLASSIFICATION" FLAME SPREAD RATING BY OCCUPANCY
AND LOCATIONS TABLE. (2022 CBC 803.13)
14. INTERIOR FLOOR FINISH AND FLOORCOVERINGS SHALL COMPLY WITH
CLASSIFICATION, TESTING AND IDENTIFICATION IN ACCORDANCE WITH ASTM E648 OR
NFPA 253. (2022 CBC 804)
15. FLOOR COVERING MATERIALS SHALL COMPLY WITH ASTM E 648 AND HAVE A SPECIFIC
OPTICAL SMOKE RATING NOT TO EXCEED 450 PER ASTM E 662. (2022 CBC 804.4.1)
16. FINISH MATERIALS SUBMITTED SHALL COMPLY WITH POLLUTANT CONTROLS - LOW
V.O.C. PAINTS AND ADHESIVES. (2022 CALGreen 5.504.4)
A A.3 A.7 B C D E.2 E.5 HD.2C.7 E F G
1.7
1.3
3.7
4.2
4.8
6.3
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
OPEN
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
CONFERENCE
HALLWAY
IDF
WOMENS
RESTROOM
MENS
RESTROOM
(E) ELEC
(E) TELE
(E)
BLDG
STORAGE
(E) 1HR
RATED
STAIRS
#1
OPEN
OFFICE
OPEN
OFFICE
PLAN
CHECK
WORKSTATIONS
PLAN
CHECK
COUNTER
EHS
ENTRY
RECEPTION
CONSULT
MEDIA
ROOM
PLAN
STORAGE
EMERGENCY
SUPPLIES,
PPE
WATER
SPECIMEN
STORAGE
WELLNESS
(E)
MENS
RESTROOM
(E) ELEV
MACHINE
RM
(E)
WOMENS
RESTROOM
VITAL
STATS
ENTRY
PRIVATE
OFFICE
CONSULT
OPEN
OFFICE
HALLWAY
COPY/
JANITOR
VITAL
STATS
STORAGE
RECEPTION
RESTROOM
RESTROOM
(E)
JANITOR
COPY
BOARDROOM
BREAKROOM
HALLWAY
OPEN
OFFICE
OPEN
OFFICE
(E) MAIN
ELEC
ROOM
(E) TELE
(E) ELEC
(E)
BLDG
STORAGE
BIRTH/DEATH
CERT.
STORAGE
(E) 1HR
RATED
STAIRS
#2
162 PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
P-5
P-6
P-7
5'-0"
C-1
C-1
B-1
C-2
B-1
AWP-1
A W
P -2
LVP-1
LVT-1
B-1
LVT-1
LVT-1
LVT-1
SDT-1
C-1
C-1
LVP-1
NIC
NIC
(E) MAIL
ROOM
P-5
P-6
P-7
P-5
P-6
P-7
5'-0"
5'-0"
TYP.
TYP. AT
OFFICES
B-1 TYP.
C-1
B-1
C-1 TYP.
B-1
C-1 TYP.
B-1
C-1 TYP.
B-1 TYP.
C-1 TYP.
B-1 TYP.
C-1 TYP.
B-1 TYP.
TYP. AT
OFFICES
C-1
B-1
P-8
ALIGN W/ CEILING ABOVE
22'-0"
A L
IG
N
W
C E
IL
IN
G A
B O
V E
LVP-1
LVP-1
LVT-1
P-3
PT-3
P-3
P-4
P
-4AWP-1
A W
P -1
LVT-1
LVT-1
A W
P -1
P-7
LVP-1 P
-4
C-1 TYP.
B-1 TYP.
LVP-1
A5.01
A5.02
P-5
P-6
P-7
P-5
P-6
P-7
P-5
P-6
P-7
TYP. AT
OFFICES
09.08
09.08
P -8
P -8 P
-8
P -8 P
-8
P -8 P
-8
P -8 P
-8
P -8
P -8
P -8 P
-8P -8
P-8
P-8
P-8
P-8
P-8
P-8
P-8
P-8
P-8
P -8
P -8
P-4
GL-1
AWP-1
G R
-1
09.05
B-1
G L
-1
G L
-1
G L
-1
GL-1
GL-1
GL-1
33'-9"
COPY /
MAIN
ENTRY
TYP.
GF-1
G F-1
GF-1
GF-1
GF-1
TYP. AT
OFFICES
GF-1
GF-1
SD2
09.46
09.46
09.46
09.46 09.46
B-1
B-2
B-2
B-3
B -3
B-3
B -3
A4.01
A4.01
B-1
B-1
B-1
B-1
B-1
B-1
P-1 TYP.
P-1
P-1
TYP.
TYP.
P-1
P-1 TYP.
C-1
B-1
P-1
C-1
P-1
B-1
09.53
B-3
B-3
B-3
B-3
B-3
B-3
B-3
B-3
B-3
B-3
B -3
B -3 B
-3
B -3 B
-3 B -3
B -3
B -3 B -3
B -3 B
-3 B -3
B -3
B -3
P-1 TYP.
P-1 TYP.
P-1 TYP.
P-1
B -3
B -3
P-1 TYP.
B -1
B-1
P-1
09.25
09.25
09.25
B-1
GL-1
M A
R K
E R
B O
A R
D G
L A
S
SB-1
P-1
P-1
B-1
R e v is io n
D a te
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
ARCHITECTURE ENGINEERING INTERIOR DESIGN
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
LPADesignStudios.com
5301 California Avenue, Suite 100
Irvine, California 92617
D e v e lo p e d f o r
Checked By
Scale
Job Number
S u b m it ta l D a te
C
IT
Y S
U B
M
IT
T A
L
/2
/2
This document and all other project documents, ideas, aesthetics and designs incorporated therein are instruments of service. All project documents are copyright protected, are the property of LPA, Inc. (LPA) and cannot be lawfully used in whole or in part for any project or purpose except as set forth in the contractual agreement between LPA and its Client. The unauthorized disclosure and/or use of the project documents (including the creation of derivative works), may give rise to liability for copyright infringement, unlawful disclosure, use or misappropriation of property rights held by LPA. The unauthorized use of the project documents will give rise to the recovery of monetary losses and damages including attorney fees and costs for which the unauthorized user will be held liable.
Project documents describe the design intent of the work and are not a representation of as-built or existing conditions. LPA is not responsible for any discrepancies between the project documents and the existing conditions.
© LPA, Inc.
1/8" = 1'-0"
E
V a n d e rb ilt W a y
S a n B e rn a rd in o
C
A
S A
N B
E R
N A
R D
IN
O
C O
U N
T Y
D P
H
F
IR
S T
F L
O O
R T
.I
S A
N B
E R
N A
R D
IN
O
C O
U N
T Y
E
V a n d e rb ilt W a y
S a n B e rn a rd in o
C
A
01 - FLOOR FINISHES
PLAN
A2.21
32468
SD/NF/KR
KEYNOTES
09.05 EXISTING CONCRETE FLOORING TO BE THOROUGHLY CLEANED
AND CLEARED OF ALL DEBRIS. PATCH, RESURFACE, AND APPLY
SEALANT. SEAL WITH RESTOCRETE, RESTO-SEAL WB
(WATER-BASED), SATIN FINISH, CONTACT MAURICO MARENCO,
RESTROCRETE. MAURICIOM@RESTOCRETE.COM 714-763-0505
09.08 (E) STAIRS: ALL FINISHES TO REMAIN. PROTECT IN PLACE.
09.25 TILE: ALIGN FLOOR AND WALL TILE. AVOID SMALL PIECES AT
VISIBLE ENDS. PRIOR TO INSTALLATION, CONTACT ARCHITECT FOR
FIELD REVIEW.
09.46 FLOOR FINISH: WHERE TRANSITION HEIGHTS EXCEED ACCESSIBLE
TRANSITION REQUIREMENT OF 1 /2" OR LESS, PROVIDE FLOOR
MATERIAL TO RAMP UP LOWER SURFACE TO HIGHER SURFACE.
PROVIDE TRANSITION PIECE AS NOTED ON DRAWINGS.
09.53 FLOOR TRANSITION STARTS AT THE EDGE OF THE MULLION.
LEGEND
GENERAL NOTES
1/8" = 1'-0"
A2.21 05FINISH PRICING PLAN
N
PROJECT NORTH
GF-1 GLASS FILM METWEST
36" HIGH BAND AT OFFICES & CONF.
ROOMS FRONTS. 60" HIGH AT BREAKROOM
BANQUETTE GLASS. COLOR AND OPACITY
TO MATCH DUSTED CRYSTAL. PROVIDE
OPAQUE WAVE LINEWORK, SEE
ELEVATION.
GR-1
CUSTOM VINYL WALL
GRAPHIC
ARC RIOT COLOR
CUSTOM DESIGN, FULL COLOR, SIZE:
WIDTH OF WALL X 9'-0" HIGH, MATTE
FINISH, PROVIDE SITE SURVEY, PROVIDE
PDF PROOFS FOR ARCHITECT'S REIVEW.
CONTACT: KERRI MENHAJI,
kerri.menhaji@riotcolor.com, (949) 230-8457
GL-1
BACK PAINTED
MAGNETIC WHITEBOARD
CLARIDGE
MAGNETIC GLASS WHITEBOARD, COLOR:
TBD. PROVIDE INVISI-MOUNT. SEE
ELEVATIONS.
AWP-2
ACOUSTICAL PANEL W/
CUSTOM GRAPHIC
MDC INTERIOR
SOLUTIONS
ZINTRA, CUSTOM IMAGE PRINT ON FROST
BASE
CONTACT: JENNIFER HOLMES
JHOLMES@MDCWALL.COM
AWP-1
ACOUSTICAL WALL
PANEL
ACOUFELT
SOLIDS WALL PANEL, COLOR: METAL,
PANEL SIZE: 48" X 110" x 24mm, PANELS TO
BE CUT PER DESIGN, SEE ELEVATIONS.
PL-3 PLASTIC LAMINATE FORMICA 8792-58, WINTER SKY, MATTE TEXTURE
PL-2 PLASTIC LAMINATE FORMICA
7223C-58, NEW WHITE, MATTE TEXTURE,
COLORCORE2
PL-1 PLASTIC LAMINATE FORMICA 5796-NG, GRAPHITE ELM, NATURAL GRAIN
SS-3 QUARTZ SURFACE
SILESTONE BY
COSENTINO
STYLE:SILESTONE BASIC
FINISH: POLISHED
COLOR: MARENGO
SS-2 QUARTZ SURFACE CAESARSTONE 1141 PURE WHITE
SS-1 QUARTZ SURFACE CAESARSTONE 5110 ALPINE MIST
P-8 ACCENT PAINT SHERWIN WILLIAMS SW9141, WATERLOO, EGGSHELL FINISH
P-7 ACCENT PAINT SHERWIN WILLIAMS
SW 9148 SMOKY AZURITE, EGGSHELL
FINISH
P-6 ACCENT PAINT SHERWIN WILLIAMS
SW 9147 FAVORITE JEANS, EGGSHELL
FINISH
P-5 ACCENT PAINT SHERWIN WILLIAMS
SW 9142 MOSCOW MIDNIGHT, EGGSHELL
FINISH
P-4 ACCENT PAINT SHERWIN WILLIAMS
SW 6250 GRANITE PEAK, EGGSHELL FINISH
& FLAT AT CEILINGS/SOFFITS.
P-3 ACCENT PAINT SHERWIN WILLIAMS
SW 9172 STUDIO CLAY, EGGSHELL FINISH
& FLAT AT CEILINGS/SOFFITS.
P-2 ACCENT PAINT SHERWIN WILLIAMS
SW 7643 PUSSYWILLOW, EGGSHELL FINISH
AT WALLS. EGGSHELL FINISH AT
RESTROOM CEILINGS ONLY.
P-1 GENERAL PAINT SHERWIN WILLIAMS
SW 7006 EXTRA WHITE, EGGSHELL FINISH
AT WALLS & FLAT AT CEILINGS/SOFFITS
PT-3
WALL TILE
(BREAKROOM)
EMSER
STYLE: ORNAMI
COLOR: WASHI
SIZE: 2" X 6"
GROUT: CUSTOM BUILDING PRODUCTS
GROUT COLOR: #645 STEEL BLUE
CONTACT: JUAN CAMARILLO
JUANCAMARILLO@EMSER.COM
PT-2
WALL TILE
(RESTROOMS)
DALTILE
STYLE: ARTCRAFTED AC23
COLOR: COCONUT
SIZE: 3" X 12"
GROUT: CUSTOM BUILDING PRODUCTS
GROUT COLOR: #643 WARM GRAY
CONTACT: MIRA CLUTTER
MIRA.CLUTTER@DALTILE.COM
PT-1
PORCELAIN TILE
(FLOOR TILE)
STONE SOURCE
STYLE: PAVIMENTI ARENA
COLOR: MATRIX CINDER
SIZE: 12" X 24"
INSTALLATION PATTERN: MONOLITHIC
GROUT: CUSTOM BUILDING PRODUCTS
GROUT COLOR: #335 WINTER GRAY
CONTACT: DAVID ALONZO
DALONZO@STONESOURCE.COM
SDT-1 STATIC DISSIPATIVE FLEXCO
STYLE: STATIC DISSIPATIVE (DISS)
COLOR: GRAY/DARK GRAY 42
SIZE: 24" X 24"
LVT-1 LUXURY VINYL TILE
MANNINGTON
COMMERCIAL
STYLE: GROOVE
COLOR: LONDON FOG C119
SIZE: 18" X 18"
CONTACT: JULIE KAESER...
LVP-1 LUXURY VINYL PLANK SHAWCONTRACT
STYLE: REPOSE 4089V
COLOR: CANOE 89103
SIZE: 7.13" X 48"
INSTALLATION PATTERN: STAGGER
CONTACT: TARA LOWMAN
TARA.LOWMAN@SHAWCONTRACT.COM
WD-1 WOOD JUNKERS
WOOD TYPE: OAK
COLOR: DRIFTWOOK GREY TEXTURED
SIZE: 20.5 X 140MM SOLID PLANK (3/4"
THICK)
INSTALLATION PATTERN: STAGGER...
UP-1 UPHOLSTERY
MOMENTUM
TEXTILES
PATTERN: CANTER EPU
COLOR: NIGHT
BACKING: POLYESTER
CONTACT: ELISE OZAWA
EOZAWA@MOMTEX.COM
C-2 ACCENT CARPET TILE PATCRAFT
STYLE: I0635 RUNNING STITCH
COLOR: 00570 BRAID
SIZE: 18" X 36"
INSTALLATION PATTERN: STAGGARD
CONTACT: SUE EWING
SUE.EWING@PATCRAFT.COM
C-1 GENERAL CARPET TILE SHAWCONTRACT
STYLE: ENCLAVE TILE 5T371
COLOR: STONE 71595
SIZE: 18" X 36"
INSTALLATION PATTERN: MONOLITHIC
CONTACT: TARA LOWMAN
TARA.LOWMAN@SHAWCONTRACT.COM
B-4 VINYL BASE TARKETT
4" HIGH VINYL BASE. COVE AT RESILIENT
FLOORING & STRAIGHT AT CARPET.
COLOR: MYSTIFY CG 469
B-3 VINYL BASE TARKETT
4" HIGH VINYL BASE. COVE AT RESILIENT
FLOORING & STRAIGHT AT CARPET.
COLOR: STORM CLOUD CG71
B-2 VINYL BASE TARKETT
4" HIGH VINYL BASE. COVE AT RESILIENT
FLOORING & STRAIGHT AT CARPET.
COLOR: HARVEST TIME CB VL1
B-1 VINYL BASE TARKETT
4" HIGH VINYL BASE. COVE AT RESILIENT
FLOORING & STRAIGHT AT CARPET.
COLOR: 460 COTTON W
TAG DESCRIPTION MANUF. NOTES
FINISHES SCHEDULE
A A d d e n d u m
A
/1 /2
A
7/
/2
TV
MW
T V
WDS
TVTV
TV
TV
T V
LED LEDLED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED LED
L E
D L
E D
L E
D L
E D
L E
D L
E D
L E
D L
E D
L E
D L
E D
L E
D L
E D
L E
D L
E D
L E
D L
E D
L E
D L
E D
L E
D
L E
D L
E D
L E
D L
E D
L E
D L
E D
L E
D L
E D
MW
W D
S
FEC
A A.3 A.7 B C D E.2 E.5 HD.2C.7 E F G
1.7
1.3
3.7
4.2
4.8
6.3
A4.01
A4.01
"F
U L
L T
IL
E
S
P-4
P-4
P-4
P-3
8' - 6"
ACP-1
8' - 0"
GYP-1
8' - 0"
GYP-1
8' - 0"
GYP-1
9' - 0"
GYP-1
8' - 0"
GYP-1
9' - 0"
ACT-1 TYP.
WD-1
BOARDROOM
WATER
SPECIMEN
STORAGE
EMERGENCY
SUPPLIES,
PPE
PLAN
STORAGE
HALLWAY
WOMENS
RESTROOM
MENS
RESTROOM
IDF
OPEN
OFFICE
OPEN
OFFICE
PLAN
CHECK
WORKSTATIONS
OPEN
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
137 CONFERENCE
OPEN
OFFICE
MAIN
ENTRY
WELLNESS
COPY
RESTROOM
RESTROOM
OPEN
OFFICE
OPEN
OFFICE
OPEN
OFFICE
OPEN
OFFICE
CONSULT
PRIVATE
OFFICE
VITAL
STATS
ENTRY
RECEPTION
VITAL
STATS
STORAGE
EHS
ENTRY
RECEPTION
PLAN
CHECK
COUNTER
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
BREAKROOM
HALLWAY
HALLWAY
HALLWAY
MEDIA
ROOM
CONSULT
HOTELING:FIELD
SUPPORT
6X6
COPY/
BIRTH/DEATH
CERT.
STORAGE
(E) ELEC
(E) TELE
(E)
BLDG
STORAGE
(E) MAIN
ELEC
ROOM
(E) 1HR
RATED
STAIRS
#2
(E) 1HR
RATED
STAIRS
#1
(E) TELE
(E) ELEC
(E)
BLDG
STORAGE
COPY /
02.06
02.06
16'-0"
8' - 0"
GYP-1
09.15
09.15
A9.10
A9.2207
A9.22
A9.22
A9.22
3'-8" 4"
(11) FULL TILES
22'-0" 4" 3'-8"
A9.22
A9.22
A9.22
A9.22
A9.22
A9.22
A9.22
A9.22
A9.22
A9.22
8' - 0"
GYP-1
A9.22
A9.22
A9.12
A9.12
A9.22
A9.22
A9.22
A9.22
A9.22
A9.22
A9.22
A9.22
8' - 0"
GYP-1
9' - 0"
GYP-1
P-2
P-2
8' - 0"
GYP-1
8' - 6"
GYP-1
9' - 0"
ACT-1
8' - 6"
GYP-1
9' - 0"
ACT-1
WD-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
9' - 0"
ACT-1
3' -4
A9.1005
A9.21
A9.21
A9.21
A9.21
A9.21
A9.21
CEILING TYPE, SEE ABOVE
EXIT SIGN
EXISTING(E)
9'-0"
XXX-1
CEILING HEIGHT, TYPICAL U.O.N.
ACP-1: ACOUSTICAL 2X2 CEILING TILE, SPEC: ACOUFELT,
COLLECTION: FRACTURE CEILING PANELS (PREMIER), DESIGN:
ORNAMENTAL, COLOR: ME03 METAL, 12MM,
GRID: ARMSTRONG, 2X2 PRELUDE 15/16" FLAT T-GRID, COLOR:
WHITE, SEE DETAIL
BORDER: ACOUFELT, COLOR: WINE BARREL WQ03. 1/2" THICK
REP CONTACT: JESSICA OSBORNE -
jessica.osborne@acoufelt.com, (619)925-2060
ACP-2: 2X2 ACOUSTICAL CEILING TILE (ABOVE SPECIALITY
BLADES): ARMSTRONG DUNE 2X2 9/16" BELVELED TEGULAR
EDGE.
SPECIALITY BLADES (CLIPPED BELOW DUNE TILES): TURF
DESIGNS, SWITCHBLADE, PROFILE TYPES: STANDARD 6" (B),
SHALLOW 2.5" (C), ORGANIC 6" (BF). CONNECTION: BOLT SLOT
FOR 9/16" SLOT FOR 9/16" SLOT TEE GRID, COLOR: LIGHT GREY
04. SEE RCP FOR DESIGN INTENT.
GRID: 2X2 ARMSTRONG SILHOUETTE XL 9/16" BOLT SLOT
SUSPENSION SYSTEM WITH 1/4" REVEAL, NOTE: 2X2 TILES TO
BE TIED INTO 2X4 SYSTEM IN ROOM. SEE DETAIL
REP CONTACT: SHERYL GAYESKI -
sgayeski@levellines.com, (630)258-4848
CEILING SEISMIC JOINT, SEE DETAIL
ACT-1: 2 X 4 ARMSTRONG SUSPENDED ACOUSTICAL
CEILING: CEILING TILE: DUNE 2x4 9/16" BEVELED TEGULAR
EDGE. GRID: SILHOUETTE XL 9/16" SUSPENSION SYSTEM
WITH 1/4" REVEAL WITH 4" AXIOM TRIM WITH VERTICAL
RISER AT ALL FLOATING OPEN OFFICE CLOUDS -COLOR:
BLIZZARD WHITE. SEE DETAIL
GYP-1: FRAMED GYPSUM BOARD CEILING,
MOISTURE-RESISTANT AT RESTROOMS. SEE DETAIL
CENTER DEVICES ON CLG TILE - TYP INCLUDED BUT NOT
LIMITED TO THE FOLLOWING: SPRINKLER, FIRE STROBE,
SPEAKERS, DAYLIGHT & OCCUPANCY SENSORS.
EQ EQ
E Q
E Q
HATCHED AREA INDICATS EXISTING SPACE TO REMAIN AND
NOT BE INCLUDED IN SCOPE OF WORK
FINISH SYMBOL
FINISH CODE - SEE FINISH SCHEDULE A2.21
/01 A9.21
/7 A9.10
/05 A9.21
OPEN CEILING: SEE GENERAL NOTE 7.
/01 A9.21
/01 A9.21
NOTE: SEE SHEET E6.10 FOR LIGHT FIXTURE SCHEDULE.
REFER TO ELECTRICAL.
1. REFER TO SPECIFICATIONS "G SERIES " FOR FINISH MATERIAL
PERFORMANCE AND EXECUTION OF W ORK. SEE FINISH SCHEDULE ON SHEET
A2.21 FOR MATERIALS.
2. GENERAL CONTRACTOR AND ELECTRICAL SUBCONTRACTORS ARE
RESPONSIBLE FOR ALL INFORMATION FOUND ON BOTH THIS SHEET AND THE
ELECTRICAL NOTES.
3. CEILING: THE DESIGN AND INSTALLATION OF NEW SUSPENDED SEISMIC
CEILING GRID TO BE IN ACCORDANCE WITH ASCE 7-05. SEE DETAILS ON
A9.21.
4. CEILING PENETRATIONS: WHERE PENETRATIONS OCCUR AT NEW SEISMIC
CEILING LOCATIONS, PROVIDE OVERSIZED RING. SLEEVE, OR ADAPTER
THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST
ONE INCH IN ALL HORIZONTAL DIRECTIONS, SEE DETAIL
5. CEILING: ALL ACCESS PANEL(S) IN GYP. BD. CEILING TO BE FLUSH,
FRAMELESS, MUD-IN FIBERGLASS CEILING ACCESS PANELS, U.O.N. PAINT TO
MATCH CEILING. CONFIRM LAYOUT/LOCATION W ITH ARCHITECT PRIOR TO
INSTALLATION. SEE DETAIL
6. CEILING: CABLE TRAY, ELECTRICAL CONDUIT, AND CABLING SHALL BE
SUPPORTED INDEPENDENTLY OF THE CEILING. CABLE MANAGEMENT IN
EXPOSED CEILINGS SHALL BE BUNDLED, SLEEVED, & LOCATED ABOVE THE
CEILING CLOUDS.
7. CEILING: WHERE INDICATED ON CEILING PLAN, EXPOSED TO STRUCTURE
ABOVE SCOPE INCLUDES PREPARING ALL EXPOSED SURFACES (ALL
EXPOSED DUCTWORK, PIPING, CONDUIT, CABLE TRAYS, BACKBOXES, ETC.)
FOR PAINT. PROVIDE WALL MOUNTED DIFFUSERS WERE POSSIBLE, OR SIDE
MOUNTED DIFFUSERS AT SPIRAL RIGID DUCT WHERE REQUIRED. DIFFUSERS
AND DUCTS TO BE PAINTED, COLOR: P-1. REFER TO FINISH PLAN ON SHEETS
FOR FULL SPECIFICATION.
8. CEILING: CONFIRM CEILING HEIGHTS AS INDICATED ON PLANS ARE
ACHIEVABLE WITH EXISTING FIELD CONDITIONS. NOTIFY ARCHITECT OF ANY
DISCREPANCIES.
9. CEILING: ACT-1 HEIGHT IS SET AT 9'-0" U.O.N.
10. CEILING: COORDINATE MAIN RUNNER WITH RECESSED LINEAR LIGHT
FIXTURE LOCATIONS.
11. HVAC: REFER TO MECHANICAL DRAWINGS FOR ALL DIFFUSER LOCATIONS,
DUCTWORK. THERMOSTATS AND EQUIPMENT.
12. HVAC:…