Amendment 2 Attachment 1 Specifications 20200812_CC.pdf
PDF 6 MB Posted
- Attached to
- Protective Shielding (Re-Solicitation) Federal contract opportunity
- Solicitation number
- 70T05020R9DMED049
About this file
This document outlines requirements for protective shielding to mitigate transmission of infectious agents. The solicitation seeks proposals for physical barriers including panels, posts, and stands to partition spaces in airports and screening areas. Offerors must provide fully assembled TDC shielding units along with other configurable system components to assemble on site. The Transportation Security Administration intends to award multiple IDIQ contracts with a minimum $10,000 guarantee and maximum $40,000,000 ceiling across all awards. The first ordering period is one year from date of award with subsequent annual periods. Delivery requirements include initial shipments within 14-28 days of award ramping up to 150 units every seven days starting 35 days after award. The solicitation includes specifications for materials, dimensions, finishes, and accessories for various shielding configurations covering ticket/divestment areas, screening tables, EDS machines, and other screening locations. Proposals are due August 14, 2020.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment 2 Attachment 2 Schedule 20200812.xlsx | XLSX spreadsheet | |
| 70T05020R9DMED049 Amendment 0002.pdf | ||
| Amendment 1 Attachment 2 Schedule 20200811.xlsx | XLSX spreadsheet | |
| Amendment 1 Attachment 1 Specifications 20200811.pdf | ||
| 70T05020R9DMED049 Amendment 0001.pdf | ||
| Attachment 1 Specifications 20200807_CC.pdf | ||
| Attachment 3 Past Performance Questionnaire 20200807_CC.docx | DOCX document | |
| Attachment 2 Schedule 20200807_CC.xlsx | XLSX spreadsheet | |
| Attachment 4 Additional Information Applicable to the Solicitation Phase Only 20200807_CC.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Transportation Security Administration COVID-19 Shielding Requirements and Specification
Aug 12, 2020
When a minimum and maximum size are specified, the product may range anywhere in between the minimum and maximum. The abbreviations “Min” for minimum and “Max” for maximum are used throughout.
TDC Shielding – Standard Configuration Configuration Number: TSA-TDC-STD-3000
TDC Shielding Specifications June 2020
TDC Shielding – Podium Configuration Configuration Number: TSA-TDC-POD-3000
TDC Shielding – BPSS Configuration Configuration Number: TSA-TDC-BPS-3000
• Manufacturer shall provide cleaning and maintenance instructions that will preserve the integrity of the glass and not cause scratching or discoloration
• Shielding height shall reach 78 inches from floor to ensure clearance in airports with 8-foot (96-inch) ceilings to maintain compliance with fire codes, proper operation of sprinkler systems (see NFPA 13), air flow, etc. and to ensure sufficient shielding for standing officers and public
• All shielding shall have a Min 2-inch to a Max 4-inch clearance from the floor to allow for cleaning (4 inches is preferred)
• Stanchions shall have a diameter between a Min of 2.75-inches and a Max of 3 inches (if circular in shape) or be a Min 2.75 square inch to a Max 3 square inch (if square in shape).
• All shielding shall be freestanding; Products shall not require drilling into any floor surface.
• Standard configuration and Podium Configuration for the TDC shielding includes: (1) Front Panel, (2) Side Panels, (2) Wing Panels and
(1) Interior or Exterior, Removable Shelf w/ Cord Cut-Out
• Opening between top and bottom panels may range between a Min of 10 inches to a Max of 16 inches
• Frame:
▪ Width: Shall range between a Min of 30 inches to a Max of 32 inches
▪ Full Height (top of post to bottom of wheels): 78 inches
▪ Shall be black aluminum or black steel with 4-sided dovetail (or similar) grooves to secure shielding
▪ Wheels to provide stability, 2 of which shall be locking, sized appropriately to prevent tripping hazard(s);
Crossbar may be included if needed to support unit but cleaning clearance shall be observed
• Clear Top Panel:
▪ Top Panel Height: Shall range between a Min of 24 inches to a Max of 26 inches
▪ Clear acrylic or other like material with a Min of ¼ inch thickness
▪ Panel placement shall be adjustable (by a stopping mechanism within the post) by 4 inches to accommodate range of equipment in use (panel cannot exceed top of post).
▪ Speaker grill shall range between a Min of 5.6 inches to a Max of 7 inches in diameter, include a non-woven fabric insert to reduce the of airborne droplets while allowing two-way communication, and centered on the panel between a Min of 54 inches to a Max of 60 inches from the ground
• Bottom Opaque Panel:
▪ Shall be opaque or frosted
▪ Min of ¼ inch thickness
▪ Height may vary depending on cleaning clearance, opening and use of crossbar on frame but shall be sufficient to provide cord coverage
General Notes & Specifications
TDC Notes & Specifications
TDC Front Panel – Consists of Frame, Clear Top Panel and Opaque Bottom Panel
▪ Width: 24 inches
▪ Overall Height (top of post to bottom of wheels): 78 inches
▪ Shall be black aluminum or black steel with 4-sided dovetail (or similar) grooves to secure shielding
▪ Locking wheels to provide stability, sized appropriately to prevent tripping hazard(s); Crossbar may be included if needed to support unit but cleaning clearance shall be observed
• Clear Top Panel:
▪ Top Panel Height: Shall range between a Min of 24 inches to a Max of 26 inches
▪ Clear acrylic or other like material with a Min of
¼ inch thickness
▪ Panel be adjustable downwards by 4 inches to accommodate range of equipment used in the field
• Bottom Opaque Panel:
▪ Shall be opaque or frosted
▪ Min of ¼ inch thickness
▪ Height may vary depending on cleaning clearance, opening and use of crossbar on frame but should be sufficient to provide cord coverage
• Wings:
▪ Width: 24 Inches
▪ Height: Shall range between a Min of 24 inches to a Max of 26 inches (Panel sits between a Min of 52 inches to a Max of 54 inches above the ground)
▪ Joins on post via dovetail (or similar) grooves on single frame
▪ To avoid injury, corners shall be shaped or padded with rubber or safety plastic.
• Shelves:
▪ Width of the shelves shall be the entire width of the front panel (front post to front post) and attached to the posts
▪ Length of Interior Shelf – Shall range between a Min of 18 inches to a Max of 24 inches
▪ Length of the Exterior Shelf shall range between a Min of 10 inches to a Max of 12 inches
• Boarding Pass Scanner Configuration:
▪ The BPSS shelf shall be mounted on a post that shall range between a
Min of 40 inches to a Max of 44 inches in height with a base that shall range from a Min of 13 inches to a Max of 14 inches.
▪ The shelf dimensions shall range between a Min of 9 inches to a Max of 12 inches in length and a Min of 6 inches to a Max of 8 inches in width
▪ The top of the shelf shall have a non-slip surface
TDC Side Panel & Wings– Consists of Frame, Clear Top Panel and Opaque Bottom Panel & Clear Wings
Shelves & BPSS Configuration
Divest Shielding – Full Configuration Configuration Number: TSA-DIV-FUL-3000
Divest Shielding Specifications
Divest Shielding – Mid-Size Configuration Configuration Number: TSA-DIV-MID-2000
Divest Shielding - Single Open Position Panel Configuration Number: TSA-DIV-SIN-1030
Divest Shielding – ASL, Macdonald Humfrey Configuration Number: TSA-DIV-ASL-3000
Divest Shielding – ASL, Scarabee and Vanderlande
Configuration Number: TSA-DIV-ASL-3000
Single divest panels may be added as needed to accommodate an airport’s specific configuration needs.
Divest Shielding - Single Open Position Panel Configuration Number: TSA-DIV-SIN-1030
Divest Shielding - Single Closed Position Panel Configuration Number: TSA-DIV-SIN-1048 scratching or discoloration
• All shielding shall have a Min 2-inch to a Max 4-inch clearance from the floor to allow for cleaning (4 inches is preferred)
• Shielding height shall reach 78 inches from floor to ensure clearance in airports with 8-foot (96-inch) ceilings to maintain compliance with fire codes, proper operation of sprinkler systems (see NFPA 13), air flow, etc. and to ensure sufficient shielding for standing officers and public
• Stanchions shall have a diameter between a Min of 2.75-inches and a Max of 3 inches (if circular in shape) or be a Min 2.75 square inch to a Max 3 square inch (if square in shape).
• Divest configurations vary based on the number of closed position panels and open position panels required; Single panels may be ordered separately as needed to accommodate the needs of each airport
• Divest panels shall have the ability to be angled to accommodate curvatures (as seen in some ASL configurations)
▪ Width: 48 inches
▪ Full Height (top of post to bottom of base): 78 inches
▪ Shall be black aluminum or black steel with 4-sided dovetail (or similar) grooves to secure shielding
▪ Base supports shall be low-profile to prevent tripping hazard, with a range between a Min 13 inch to a Max 14-inch base and sufficiently weighted to secure shielding and/or equipment
• Panel:
▪ Height: 48 inches (30-inch clearance from the ground)
▪ Clear acrylic or other like material with a Min of ¼ inch thickness
▪ Speaker grill shall range between a Min of 5.6 inches to a Max of 7 inches in diameter, include a non-woven fabric insert to reduce the of airborne droplets while allowing two-way communication, and centered on the panel between a Min of 54 inches to a Max of 60 inches from the ground
General Notes & Specifications
Divest Notes & Specifications
Divest Closed Position Panel
▪ Full Height (top of post to bottom of base): 78 inches
▪ Shall be black aluminum or black steel with 4-sided dovetail (or similar) grooves to secure shielding
▪ Base supports shall be low-profile to prevent tripping hazard, with a range between a Min 13 inch to a Max 14-inch base and sufficiently weighted to secure shielding and/or equipment
• Panel:
▪ Height: 30 inches (48-inch clearance from the ground)
▪ Clear acrylic or other like material with a Min of ¼ inch thickness
▪ Speaker grill shall range between a Min of 5.6 inches to a Max of 7 inches in diameter, include a non-woven fabric insert to reduce the of airborne droplets while allowing two-way communication, and centered on the panel between a Min of 54 inches to a Max of 60 inches from the ground
Divest Open Position Panel
Search Table Shielding – Full Configuration Configuration Number with 30-inch Panel (as shown): TSA-SEA-FUL-5030
Configuration Number with 48-inch Panel: TSA-SEA-FUL-5048 Configuration Number for 24-inch single panel: TSA-SEA-SIN-1024 Configuration Number for 48-inch single panel: TSA-SEA-SIN-1048
Single panels may be Procured separately as needed to accommodate various configurations.
Search Table Shielding Specifications
Search Table Shielding Specifications_
Search Table Shielding – Mid-Size Configuration Configuration Number with 30-inch Panel (as shown): TSA-SEA-MID-4030
Configuration Number with 48-inch Panel: TSA-SEA-MID-4048
Single panels may be procured separately as needed to accommodate various configurations.
Search Table Shielding Specifications_
Search Table Shielding – In-line Configuration Configuration Number with 30-inch Panel (as shown): TSA-SEA-LIN-3030
Configuration Number with 48-inch Panel: TSA-SEA-LIN-3048
Option to have 48-inch panel instead of 30-inch panel
Single panels may be procured separately as needed to accommodate various configurations.
Search Table Shielding - ASL, MacDonald Humfrey and Vanderlande Configuration Number: TSA-SEA-ASL-7000
Mid-Size and/or Inline Search Table Shielding Configurations, in combination with single panels, may used to accommodate individual and/or varying ASL divest shielding needs.
Search Table Shielding – ASL, Scarabee Configuration Number: TSA-SEA-ASL-8000
Mid-Size and/or Inline Search Table Shielding Configurations, in combination with single panels, may be used to accommodate individual and/or varying ASL divest shielding needs.
Search Table Shielding – Single Panel, 24 inches Configuration Number: TSA-SEA-SIN-1024
Search Table Shielding – Single Panel, 48 inches Configuration Number: TSA-SEA-SIN-1048 scratching or discoloration
• Shielding height shall reach 78 inches from floor to ensure clearance in airports with 8-foot (96-inch) ceilings to maintain compliance with fire codes, proper operation of sprinkler systems (see NFPA 13), air flow, etc. and to ensure sufficient shielding for standing officers and public
• All shielding shall have a Min 2-inch to a Max 4-inch clearance from the floor to allow for cleaning (4 inches is preferred)
• Stanchions shall have a diameter between a Min of 2.75-inches and a Max of 3 inches (if circular in shape) or be a Min 2.75 square inch to a Max 3 square inch (if square in shape).
• Panel quantities and configurations may need to be adjusted to accommodate unique airport requirements
▪ Width: 30 inches
▪ Full Height (top of post to bottom of base): 78 inches
▪ Shall be black aluminum or black steel with 4-sided dovetail (or similar) grooves to secure shielding
▪ Base supports shall be low-profile to prevent tripping hazard, with a range between a Min 13 inch to a Max 14-inch base and sufficiently weighted to secure shielding and/or equipment
• Panel:
▪ Height: 74 inches (4-inch clearance from the ground to allow for cleaning)
▪ Top (48 inches) made from clear acrylic or other like material with a Min of ¼ inch thickness
▪ Wall base (lower 26 inches) shall be opaque or frosted Min of ¼ inch thickness
General Notes & Specifications
Search Table Notes & Specifications
ETD Cabinet Panel (panel behind blue cabinet in pictures)
▪ Full Height (top of post to bottom of base): 78 inches
▪ Shall be black aluminum or black steel with 4-sided dovetail (or similar) grooves to secure shielding
▪ Base supports shall be low-profile to prevent tripping hazard, with a range between a Min 13 inch to a Max 14-inch base and sufficiently weighted to secure shielding and/or equipment
• Panel:
▪ Height: 74 inches (4-inch clearance from the ground to allow for cleaning)
▪ Top (48 inches) made from clear acrylic or other like material with a Min of ¼ inch thickness
▪ Wall base (lower 26 inches) shall be opaque or frosted
▪ Speaker grill shall range between a Min of 5.6 inches to a Max of 7 inches in diameter, include a non-woven fabric insert to reduce the of airborne droplets while allowing two-way communication, and centered on the panel between a Min of 54 inches to a Max of 60 inches from the ground
▪ Width: 24 inches
▪ Full Height (top of post to bottom of post): 78 inches
▪ Shall be black aluminum or black steel with 4-sided dovetail (or similar) grooves to secure shielding
▪ Base supports shall be low-profile to prevent tripping hazard, with a range between a Min 13 inch to a Max 14-inch base and sufficiently weighted to secure shielding and/or equipment
• Panel:
▪ Height: 74 inches (4-inch clearance from the ground to allow for cleaning)
▪ Top (48 inches) made from clear acrylic or other like material with a Min of ¼ inch thickness
▪ Wall base (lower 26 inches) shall be opaque or frosted Min of ¼ inch thickness
▪ Speaker grill shall range between a Min of 5.6 inches to a Max of 7 inches in diameter, include a non-woven fabric insert to reduce the of airborne droplets while allowing two-way communication, and centered on the panel between a Min of 54 inches to a Max of 60 inches from the ground
Search Table Panel, 48-Inch
Search Table Panel, 24-Inch
EDS Shielding – Standard Configuration Configuration Number: TSA-EDS-STD-3000
EDS Barrier Shielding Specifications scratching or discoloration
• Shielding height shall reach 78 inches from floor to ensure clearance in airports with 8-foot (96-inch) ceilings to maintain compliance with fire codes, proper operation of sprinkler systems (see NFPA 13), air flow, etc. and to ensure sufficient shielding for standing officers and public
• All shielding shall have a Min 2-inch to a Max 4-inch clearance from the floor to allow for cleaning (4 inches is preferred)
• Stanchions shall have a diameter between a Min of 2.75-inches and a Max of 3 inches (if circular in shape) or be a Min 2.75 square inch to a Max 3 square inch (if square in shape).
• Standard configuration for the EDS shielding includes: (1) Luggage Pass Through Panel and (2) Side Panels
▪ Width: 54 inches
▪ Full Height (top of post to bottom of base): 78 inches
▪ Shall be black aluminum or black steel with 4-sided dovetail (or similar) grooves to secure shielding
▪ Base supports shall be low-profile to prevent tripping hazard, with a range between a Min 13 inch to a Max 14-inch base and sufficiently weighted to secure shielding and/or equipment
• Top Panel:
▪ Top Panel Height: 42 inches (36-inch clearance from the ground to allow for luggage pass through)
▪ Clear acrylic or other like material with a Min of ¼ inch thickness
▪ Speaker grill shall range between a Min of 5.6 inches to a Max of 7 inches in diameter, include a non-woven fabric insert to reduce the of airborne droplets while allowing two-way communication, and centered on the panel between a Min of 54 inches to a Max of 60 inches from the ground
▪ Guidance, in the form of a sticker, stating “Push Luggage Through”, with arrows (as shown in picture above) shall be provided on center panel above opening.
General Notes & Specifications
EDS Notes & Specifications
EDS Luggage Pass Through Panel – Consists of Frame and Top Panel
• Side panels shall have the ability to be placed even with the frame, at a 45-degree angle and at a 90-degree angle
• Frame:
▪ Width: 24 inches
▪ Full Height (top of post to bottom of base): 78 inches
▪ Shall be black aluminum or black steel with 4-sided dovetail (or similar) grooves to secure shielding
▪ Base supports shall be low-profile to prevent tripping hazard, with a range between a Min 13 inch to a Max 14-inch base and sufficiently weighted to secure shielding and/or equipment
• Clear Top Panel:
▪ Height: 48 inches
▪ Clear acrylic or other like material with a Min of ¼ inch thickness
• Bottom Opaque Panel:
▪ Height: 26 inches
▪ Min of ¼ inch thickness
EDS Side Panels – Consist of Frame, Clear Top Panel and Opaque Bottom Panel
Shielding Specifications - Master Configuration Numbers Listing
Configuration # Configuration Title
TSA-TDC-STD-3000 TDC Shielding w/ Removable Interior Shelf TSA-TDC-POD-3000 TDC Shielding w/ Removable Front Shelf TSA-TDC-BPS-3000 BPSS Stand Only TSA-DIV-FUL-3000 3-Panel Divest Shielding (2 open panel, 1 closed panel) TSA-DIV-MID-2000 2-Panel Divest Shielding (1 open Panel, 1 closed Panel) TSA-DIV-SIN-1030 Single Divest Open Position Panel (panel is 30 inches in height with 48-inch clearance to the ground) TSA-DIV-SIN-1048 Single Divest Closed Position Panel (panel is 48 inches in height with 30 inch clearance to the ground) TSA-DIV-ASL-3000 Divest Shielding - ASL (3 open panels) TSA-EDS-STD-3000 3-Panel EDS Shielding (1 open panel, 2 closed panel) TSA-SEA-FUL-5030 Full-Size (2 search tables + ETD cabinet) Search Table Shielding w/ 30-inch panel option TSA-SEA-FUL-5048 Full-Size (2 search tables + ETD cabinet) Search Table Shielding w/ 48-inch panel option TSA-SEA-MID-4030 Mid-Size (1 search table + ETD cabinet) Search Table Shielding w/ 30-inch panel option TSA-SEA-MID-4048 Mid-Size (1 search table + ETD cabinet) Search Table Shielding w/ 48-inch panel option TSA-SEA-LIN-3030 In-line (1 search table + ETD cabinet in line with lane) Search Table Shielding w/ 30-inch panel option TSA-SEA-LIN-3048 In-line (1 search table + ETD cabinet in line with lane) Search Table Shielding w/ 48-inch panel option TSA-SEA-SIN-1024 24-Inch Single Search Table Panel TSA-SEA-SIN-1048 48-Inch Single Search Table Panel TSA-SEA-ASL-7000 7-Panel ASL Search Table Shielding (Covers 2 ASL, 1 Mod Set; for use with MH & Vanderlande) TSA-SEA-ASL-8000 8-Panel ASL Search Table Shielding (Covers 2 ASL, 1 Mod Set; for use with Scarabee)
Intercom Enhancement
The purpose of the intercom device is to ease communication between officers and the public which may be impaired by, but not limited to, the use of face masks, the use of face shields, people standing a significant distance from the panels in an effort to mitigate risk of virus transmission, and significant background noise such as airport public address announcements or general noise due to crowds, operation of screening equipment, HVAC systems, etc.
TSA is not requiring any specific intercom solution, however all offerors must propose an intercom solution and provide pricing in Attachment 2.
The proposed solution:
1) Shall allow for two-way communication;
2) May require an officer to have to touch the intercom to activate the system. Any touch points to activate communication in either direction shall be on the officer side of the shielding only;
3) Shall not require a member of the public to depress any button or touch any surface to communicate; and,
4) Shall operate from a non-proprietary, rechargeable battery power source.
The Schedule includes a line item for a charger for the non-proprietary batteries. There is no requirement under this contract for additional batteries.
Additional batteries will be sourced outside of this contract.
Furthermore, the contractor is reminded that any intercom solution must be merchantable and fit for use for the particular purposes described herein (see FAR 52.212-4(o)).
Intercom Specifications
Intercom Enhancement x
| TDC Shielding – Standard Configuration Configuration Number: TSA-TDC-STD-3000 |
| TDC Shielding – BPSS Configuration Configuration Number: TSA-TDC-BPS-3000 |
| Divest Shielding – Full Configuration Configuration Number: TSA-DIV-FUL-3000 |
| Divest Shielding - Single Open Position Panel Configuration Number: TSA-DIV-SIN-1030 |
| Search Table Shielding – Full Configuration |
| Search Table Shielding – Mid-Size Configuration Configuration Number with 30-inch Panel (as shown): TSA-SEA-MID-4030 |
| Search Table Shielding – In-line Configuration Configuration Number with 30-inch Panel (as shown): TSA-SEA-LIN-3030 |
| Search Table Shielding - ASL, MacDonald Humfrey and Vanderlande Configuration Number: TSA-SEA-ASL-7000 |
| Search Table Shielding – ASL, Scarabee Configuration Number: TSA-SEA-ASL-8000 |
| Search Table Shielding – Single Panel, 24 inches Configuration Number: TSA-SEA-SIN-1024 |
| EDS Shielding – Standard Configuration Configuration Number: TSA-EDS-STD-3000 |
| Shielding Specifications - Master Configuration Numbers Listing |
File details come from the government source that posted it. Updated .