Drawing qya26443a09 - Copy.pdf
PDF 120 KB Posted
- Attached to
- QYA ARSR HVAC Replacement Federal contract opportunity
- Solicitation number
- 697DCK-24-R-00106
About this file
This solicitation is seeking proposals for an HVAC replacement project at an ARSR facility in Bucks Harbor, Maine. The Federal Aviation Administration requires demolition of two existing HVAC units and associated ductwork, and installation of two new 25-ton packaged HVAC units with controls and all related components. The work must be completed within 45 calendar days. Proposals are due by February 7, 2024 to the email addresses provided. The contract will be a firm fixed price awarded to a small business. The estimated value is between $250,000 and $500,000. An optional site visit will be held on January 24, 2024 for interested offerors to attend.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 697DCK-24-R-00106 0002.pdf | ||
| Drawing qya-d-arsr-e001-bl.pdf | ||
| QYA ARSR HVAC Replacement Site Pictures - for Contractors.pdf | ||
| Requests For Information - QYA HVAC Replacement.pdf | ||
| SUMMARY OF WORK_QYA ARSR HVAC Replacement Project_Rev B.pdf | ||
| OAS 2.5 User Manual (Final).pdf | ||
| 697DCK-24-R-00106 Amendment 0001.pdf | ||
| SUMMARY OF WORK_QYA ARSR HVAC Replacement Project_Rev A.pdf | ||
| M001(I)_QYA ARSR_Rev A.pdf | ||
| 697DCK-24-R-00106.pdf | ||
| Wage Determination ME20230013 092923.pdf | ||
| SUMMARY OF WORK_QYA ARSR HVAC Replacement Project.pdf | ||
| Drawing M001(I)_QYA ARSR.pdf | ||
| Drawing qya26443m01.pdf | ||
| Drawing qya26443m04.pdf | ||
| Drawing qya26443m02.pdf | ||
| Drawing qya26443m03.pdf |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
C
B
D
NOTES:
15°
MAX.
MAX.
HORIZONTAL ELBOWS
HORIZONTAL TEE
HORIZONTAL CROSS
(TYP)(TYP)
TYPICAL SUPPORT LOCATION
FOR CABLE TRAY FITTINGS
B
E
B
A09
E
E08
BULKHEAD
PLATE
"USAF" PANEL
RAIN
HOOD
04 4 8
SCALE IN FEET
OPEN
B A09
CABLE TRAY/T-BAR CEILING DETAIL
FENDER
WASHER
4"x4" SQ. DUCT
1 5/8" x 1 5/8"
12 GA. CHANNEL
USE 1/2" EMT W/
3/8" RHMB TO
PROVIDE STANDOFF
ALL-THREAD ROD
ACOUSTICAL
CEILING TILE
UNISTRUT
CHANNELS
2x6 TRUSS BOTTOM CHORD
OR 2x6 BLOCKING
ALL-THREAD ROD
1 5/8" X 1 5/8"
12 GA. CHANNEL
METAL
CEILING GRID
A
A09
CABLE TRAY/T-BAR CEILING DETAIL
30°
4"x4" SQ.
DUCT (TYP)
2'-0"X2'-0" T-BAR
CEILING GRID
= SURFACE MOUNTED LIGHT
= LAY-IN LIGHT
= HVAC DIFFUSER
= WALL MOUNTED HEATER
FIXTURE SCHEDULE
2'-0"x3'-0" REMOVABLE
ACCESS PANEL
1 5/8"x1 5/8" UNISTRUT CHANNELS
FLUSH W/ CEILING GRID, PARALLEL
TO CABLE TRAY TO SUPPORT HANGING
CABLE TRAY
B
E08
RAIN
HOOD
1x3 STRAPPING
5/8" GYP. BOARD
REMOVABLE ACCESS
PANEL (2'-0"x3'-0")
24" CABLE TRAY
(SEE NOTES 1 THRU 5)
12" CABLE TRAY
(SEE NOTES 1 THRU 5)
CENTERLINE OF
ARSR-4 TOWER
BULKHEAD
PLATE
EXISTING
STAIRWAY PAD
6"x6" SQ.
DUCT
E
E08
BULKHEAD
PLATE
C
A
CABLE TRAY
(SEE NOTES
1 THRU 5)
1 5/8" x 1 5/8"
12 GA. CHANNEL
4"x4" SQ. DUCT
NOT TO SCALE
C
A09
CABLE TRAY/T-BAR SECTION
NOT TO SCALE
(SEE NOTE 6)
(SEE NOTE 7)
CABLE TRAY IN STORAGE
ROOM TO BE INSTALLED
ABOVE CEILING (SEE DWG
A07 FOR ELEVATIONS)
8"x8" SQ. DUCT
4"x4" SQ. DUCT (TYP)
1. CABLE TRAY SYSTEM SHALL CONFORM TO LASTEST NEMA
STANDARDS PUBLICATION UE-1 AND SHALL BE UL CLASSIFIED
AS EQUIPMENT GROUNDING CONDUCTORS.
2. ALL INTERIOR CABLE TRAY SHALL BE ALUMINUM. ALL EXTERIOR
CABLE TRAY SHALL BE HOT DIPPED GALVANIZED STEEL. NO
SUBSTITUTION OF MATERIAL ALLOWED.
3. RADIUS OF TRAY FITTINGS 12" UNLESS OTHERWISE INDICATED.
4. INTERIOR CABLE TRAY
A. ALUMINUM ALLOY 6063-T6
B. 4" SIDERAIL HEIGHT, I =2.85IN , S =1.44IN
C. 9" RUNG SPACING, I =0.0361IN , S =0.0707IN ,
MIN. CABLE BEARING SURFACE 3/4" W/RADIUSED EDGES.
D. 9" FITTING RUNG SPACING
5. EXTERIOR CABLE TRAY
A. SIDERAILS, 14GA STEEL CONFORMING TO ASTM A570
GR. 33; RUNGS STEEL CONFORMIMG TO ASTM A611
GR. C; BOTH HOT-DIPPED GALVANIZED AFTER
FABRICATION IN ACCORDANCE WITH ASTM A123
B. 4" SIDERAIL HEIGHT, I =2.56IN , S =1.46IN
C. VENTILATED TROUGH BOTTOM, I =0.432IN , S =0.0877IN
D. 18GA HOT DIPPED GALVANIZED PEAKED FLANGED COVER
W/ 1/2" PEAK AND HEAVY DUTY COVER CLAMP.
6. 2x6 BLOCKING SHALL BE PROVIDED TO CARRY 1 5/8 x 1 5/8
CHANNEL WHERE CABLE TRAY RUNS PERPENDICULAR TO CEILING
JOISTS.
7. MAX. SPACING OF CABLE TRAY SUPPORTS IS 4'-0" O.C.
8. REFERENCE DWG E01 FOR POWER PANEL INSTALLATION, DWG E02
FOR LIGHT INSTALLATION AND DWG M01 FOR HVAC INSTALLATION.
E. 94" ABOVE FINISHED FLOOR
2"
MAX
42"
56"
ANI-140
26443-A09 QYA 1
1 ZJB
11-05-99
NE-D-26443-A09/C
0 05/01/94 4418
QYA26443A09.DGN SGS
B. ANDREWS
AS BUILT
DJ/MG
2'-0"
2' -0
2/3 R 2/3 R
1/2 L
L
2'-0"
2'-0"
MAX.
MAX.
(TYP)
SEE NOTE 9
5/8" DIA
9. ALLHEATERS SUSPENDED FROM CEILING SUPPORTED BY 1/2" THREADED ROD.
REMOVABLE ACCESS
PANEL (2'-0"x3'-0")
D
A09
SEE NOTE 9
D
A09 NOT TO SCALE
ELECTRICAL PANEL SIDE VIEW
5/8" DIA
3/8" GWB
CEILING TILES
TYPICAL
ELECTRICAL PANEL
3/8" GWB
1/2" PLYWOOD
CMU WALL
REFLECTED CEILING PLAN
ARCHITECTURAL
ARSR-4
BUCKS HARBOR, ME
B. NG
File details come from the government source that posted it. Updated .