Utility_Investigation_Report.pdf

PDF 4 MB Posted

Attached to
NP-OZAR 10(2), Ozark National Scenic Riverways
Solicitation number
693C73-18-B-000013
Issued by

About this file

Utility_Investigation_Report

View the file

Other files

File Type Posted
ROBO_-NP-OZAR_10(2).ppt PPT presentation
Amendment_0003_5.3.2018.pdf PDF
Plans_Amendment_2.pdf PDF
Questions-Clarifcations_Amendment_2.pdf PDF
SCR_Amendment_2.pdf PDF
Amendment_0002_5.1.2018.pdf PDF
Amendment_0001,_4.26.18.pdf PDF
NP-OZAR_10(2)_Plans.pdf PDF
Bridge_Inspection_Report_STR_6640-005P_Alley_Spring.pdf PDF
NEPA_EA_Big_Spring_Bridge.pdf PDF
Bidder's_Qualifications_Form.doc DOC document
VETS-4212.pdf PDF
FP14_Eng.pdf PDF
Soils_and_Foundations_Report.pdf PDF
NEPA_CE_Alley_Spring_Bridge.pdf PDF
IFB_Solicitation-NP-OZAR_10(2).pdf PDF
NEPA_CE_SHPO_Concurrence_Alley_Spring_Bridge.pdf PDF
SWPPP_draft.pdf PDF
NEPA_FONSI_Big_Spring_Bridge.pdf PDF
Subcontracting_plan.doc DOC document
Bridge_Inspection_Report_STR_6640-001P_Big_Spring.pdf PDF
Synopsis_02.08.18.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

IDIQC DTFH71‐12‐D‐00001 Page 1

PRA‐OZAR10(2)

UTILITY INVESTIGATION REPORT

Federal Highway Administration (FHWA), Eastern Federal Lands Highway Division

Table of Contents

Executive Summary …………………………………………………………………………………………. 2

Utility Design Services ………………………………………………………………………………….…. 2

Power ……………………………………………………………………………………………………………… 3

Water ……………………………………………………………………………………………………………… 4

Sanitary ……………………………………………………………………………………………………….…. 4

Telecommunications ………………………………………………………………………………………. 4

USGS Stream Gauge ………………………………………………………………………………………… 4

Appendix A – Utility Plan

Appendix B – Cost Estimate

Appendix C – HDD Drilling Additives

Appendix D – Utility Contacts

Appendix E – Trench Details

IDIQC DTFH71‐12‐D‐00001 Page 3

Power:

Ozark Border Electric Cooperation has a 3‐phase 7200V service that crosses Big Spring under the west side of the bridge that runs between two conductor boxes labeled in the utility basemap as K2A59 located behind the southeast wingwall and K2A58 located east of the forward northwest wingwall. The power feeds numerous rural houses on a line of approximately 300 poles, heat tracer wires on the bridge and the Ozark National Park with 480

V service. Due to the quantity of rural residences connected to the power service, it should not be de‐energized during construction. Therefore, temporary or permanent routing around the bridge should be installed prior to bridge removal. Constructing the bridge in phases, such that an existing side of the bridge would support utilities while half of the bridge was replaced and then support the permanent transferred utilities, was considered but determined impractical due to construction schedule and cost.

A permanent relocation of the power service by horizontal directional drilling (HDD) would be the preferred option. This alternative would allow the routing to be installed prior to the bridge removal and the service switched as an independent activity of the bridge construction. The method of routing by HDD is plausible given the subsurface conditions, however due to the granular nature of the underlying soils the operation may involve the use of chemicals listed in Appendix C. Therefore, this operation will have to be vetted with the environmental constraints of allowable activities surrounding the protected waterway of the Big Spring. The estimated construction cost is included in Appendix B and an alignment for this option is included in the Utility Relocation

Plan in Appendix A. If disturbance to a natural wilderness area is a concern, the utility can be moved to the east side of the bridge in similar alignment to the jack and bore method also presented in Appendix A.

Permanent aerial relocation of the power service over Big Spring using utility poles is not an option to the Park

Service, however using temporary supports during construction and then installing the service onto the newly constructed bridge is an alternative. The National Park Service has a 480 V line that feeds the bathrooms on the north side of the bridge will be replaced inside the power conduits shown below. The power will be fed from the meter south of the bridge and two pull boxes will be located on each side of the bridge to facilitate pulling installation of the wiring through the bridge conduit.

IDIQC DTFH71‐12‐D‐00001 Page 4

Water:

There is a 6” water line owned by the National Park Service (NPS) that passes over Big Spring on the west side of the bridge in an adjacent bay to the power service. The water service source is a well that is south of the bridge and supplies water to the restrooms, camp facilities, fire hydrants and a water tower north of the bridge. A short disruption of water service could be achieved during off season times, which ideally would occur for transitioning from the existing service to a newly installed waterline that would be installed underground by HDD on an independent alignment from the bridge as depicted in Appendix A. If an underground alignment is an impractical method of installation due to environmental constraints or parkland disturbance, a temporary service alignment will need to be constructed while the bridge is being constructed. For either option, the new waterline size should be coordinated with upcoming improvements, however at this stage it is recommended to maintain a 6” diameter water main. The cost for each alternative is included in Appendix B.

Sanitary:

Similar to the water line, there is a 4” sanitary line owned by the NPS that is attached to the east underside of the bridge. The pump station for the sanitary force main is located south of the bridge and receives gravity flow from a small maintenance facility and the concessions area. From the pump station the sanitary service crosses the bridge and flows into a manhole north of the bridge and then gravity flows into another lift station which eventually enters a treatment facility inside the park. If the bridge is constructed during off season months, the sanitary facilities south of the bridge can be closed so that providing temporary service during construction would not be necessary. Therefore, the most effective option would be to shut down the line during construction and install a new line on the outside of the box beam on the east side of the bridge. If construction will occur during in‐season use of the park by‐pass pumping will be required for each option. An underground alignment, due to the additional head and friction losses will require the existing pumps to be upgraded from a 23’ to a 35’ head capacity and maintain flow of 80 gal/min. The existing information on the pumps indicate that they are at or near their design life of 40 years and the replacement pumps should more than likely be in similar size to the existing so that the existing lift station will not require significant modifications.

Telecommunications:

There is a telecommunication line that is owned by Century Link that crosses over Big Spring on the underside of the east side of the bridge. The communication line can be temporarily supported with wood poles spanning over the spring during construction and re‐routed to the west side of the bridge for permanent location inside the sidewalk as shown in the transverse section above.

USGS Stream Gauge:

The stream gauge that is operational is located on the north east bank of Big Spring mounted on a wood pole. The transducer is located on the middle pier, in the same location of the abandoned original housing unit, and is connected to the gauge by a communication line that runs under the west side of the bridge. The transducer and communication cable will be removed from the existing bridge prior to construction and reinstall by USGS personnel. Coordination of the project schedule shall be conducted with Shane Barks of USGS (ph: 573‐308‐3674) so that removal and reinstallation can occur with minimal to no disruption of construction activities.

APPENDIX A

APPENDIX B

APPENDIX C

Additional Information For additional information on the use of this product, contact your local Halliburton representative.

For questions about the Safety Data Sheet for this or other Halliburton products, contact Chemical Compliance at 1-580-251-4335.

Disclaimer Statement This information is furnished without warranty, expressed or implied, as to accuracy or completeness. The information is obtained from various sources including the manufacturer and other third party sources. The information may not be valid under all conditions nor if this material is used in combination with other materials or in any process. Final determination of suitability of any material is the sole responsibility of the user.

***END OF MSDS***

EZ-MUD® GOLD

MATERIAL SAFETY DATA SHEET

Product Trade Name: NO-SAG® Revision Date: 02-Jan-2013

1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

Product Trade Name: NO-SAG® Synonyms: None Chemical Family: Carbohydrate Application: Viscosifier

Manufacturer/Supplier Baroid Fluid Services Product Service Line of Halliburton P.O. Box 1675 Houston, TX 77251 Telephone: (281) 871-4000 Emergency Telephone: (281) 575-5000

Prepared By Chemical Compliance Telephone: 1-580-251-4335 e-mail: fdunexchem@halliburton.com

2. COMPOSITION/INFORMATION ON INGREDIENTS

Substances CAS Number PERCENT ACGIH TLV-TWA OSHA PEL-TWA Xanthan gum 11138-66-2 60 - 100% 10 mg/m3 15 mg/m3

3. HAZARDS IDENTIFICATION

Hazard Overview May cause eye irritation. Airborne dust may be explosive.

4. FIRST AID MEASURES

Inhalation If inhaled, remove from area to fresh air. Get medical attention if respiratory irritation develops or if breathing becomes difficult.

Skin Wash with soap and water. Get medical attention if irritation persists.

Eyes In case of contact, immediately flush eyes with plenty of water for at least 15 minutes and get medical attention if irritation persists.

Ingestion Under normal conditions, first aid procedures are not required.

Notes to Physician Not Applicable

NO-SAG®

5. FIRE FIGHTING MEASURES

Flash Point/Range (F): Not Determined Flash Point/Range (C): Not Determined Flash Point Method: Not Determined Autoignition Temperature (F): 400 Autoignition Temperature (C): 204 Flammability Limits in Air - Lower (%): Not Determined Flammability Limits in Air - Upper (%): Not Determined

Fire Extinguishing Media Water fog, carbon dioxide, foam, dry chemical.

Special Exposure Hazards Organic dust in the presence of an ignition source can be explosive in high concentrations. Good housekeeping practices are required to minimize this potential. Decomposition in fire may produce toxic gases.

Special Protective Equipment for Fire-Fighters

Full protective clothing and approved self-contained breathing apparatus required for fire fighting personnel.

NFPA Ratings: Health 0, Flammability 0, Reactivity 0 HMIS Ratings: Health 0, Flammability 0, Physical Hazard 0

6. ACCIDENTAL RELEASE MEASURES

Personal Precautionary MeasuresUse appropriate protective equipment. Avoid creating and breathing dust.

Environmental Precautionary Measures

None known.

Procedure for Cleaning / Absorption

Scoop up and remove.

7. HANDLING AND STORAGE

Handling Precautions Slippery when wet. Avoid creating or inhaling dust.

Storage Information Store away from oxidizers. Store in a cool, dry location.

8. EXPOSURE CONTROLS/PERSONAL PROTECTION

Engineering Controls Use in a well ventilated area.

Personal Protective Equipment If engineering controls and work practices cannot prevent excessive exposures, the selection and proper use of personal protective equipment should be determined by an industrial hygienist or other qualified professional based on the specific application of this product.

Respiratory Protection Not normally needed. But if significant exposures are possible then the following respirator is recommended:

Dust/mist respirator. (N95, P2/P3)

Hand Protection Normal work gloves.

Skin Protection Normal work coveralls.

Eye Protection Wear safety glasses or goggles to protect against exposure.

Other Precautions None known.

9. PHYSICAL AND CHEMICAL PROPERTIES

Physical State: Solid Color: White to yellow Odor: Slight pH: 7 Specific Gravity @ 20 C (Water=1): 1.5 Density @ 20 C (lbs./gallon): Not Determined Bulk Density @ 20 C (lbs/ft3): 35-55 Boiling Point/Range (F): Not Determined Boiling Point/Range (C): Not Determined Freezing Point/Range (F): Not Determined Freezing Point/Range (C): Not Determined Vapor Pressure @ 20 C (mmHg): Not Determined Vapor Density (Air=1): Not Determined Percent Volatiles: Not Determined Evaporation Rate (Butyl Acetate=1): Not Determined Solubility in Water (g/100ml): Soluble Solubility in Solvents (g/100ml): Not Determined VOCs (lbs./gallon): Not Determined Viscosity, Dynamic @ 20 C (centipoise): Not Determined Viscosity, Kinematic @ 20 C (centistokes): Not Determined Partition Coefficient/n-Octanol/Water: Not Determined Molecular Weight (g/mole): 1,000,000

10. STABILITY AND REACTIVITY

Stability Data: Stable

Hazardous Polymerization: Will Not Occur

Conditions to Avoid None anticipated

Incompatibility (Materials to Avoid)

Strong oxidizers.

Hazardous Decomposition Products

Carbon monoxide and carbon dioxide.

Additional Guidelines Not Applicable

11. TOXICOLOGICAL INFORMATION

Principle Route of Exposure Eye or skin contact, inhalation.

Inhalation May impede respiration.

Skin Contact None known.

Eye Contact May cause mild eye irritation.

Ingestion None known

Aggravated Medical Conditions None known.

Chronic Effects/Carcinogenicity No data available to indicate product or components present at greater than 1% are chronic health hazards.

Other Information None known.

Toxicity Tests

Oral Toxicity: LD50: > 5000 mg/kg (Rat)

Dermal Toxicity: Not determined

Inhalation Toxicity: Not determined

Primary Irritation Effect: Not determined

Carcinogenicity Not determined

Genotoxicity: Not determined

Reproductive / Developmental Toxicity:

Not determined

12. ECOLOGICAL INFORMATION

Mobility (Water/Soil/Air) Not determined

Persistence/Degradability BOD(5 Day): 200 mg/g COD: 1600 mg/g

Bio-accumulation Not determined

Ecotoxicological Information

Acute Fish Toxicity: Not determined Acute Crustaceans Toxicity:TLM96: > 75000 ppm (Mysidopsis bahia) Acute Algae Toxicity: Not determined

Chemical Fate Information Not determined

Other Information Not applicable

13. DISPOSAL CONSIDERATIONS

Disposal Method Bury in a licensed landfill according to federal, state, and local regulations.

Contaminated Packaging Follow all applicable national or local regulations.

14. TRANSPORT INFORMATION

Land Transportation

DOT

Not restricted

Canadian TDG Not restricted

ADR

Not restricted

Air Transportation

ICAO/IATA

Not restricted

Sea Transportation

IMDG

Not restricted

Other Transportation Information

Labels: None

15. REGULATORY INFORMATION

US Regulations

US TSCA Inventory All components listed on inventory or are exempt.

EPA SARA Title III Extremely Hazardous Substances

Not applicable

EPA SARA (311,312) Hazard Class

None

EPA SARA (313) Chemicals This product does not contain a toxic chemical for routine annual "Toxic Chemical Release Reporting" under Section 313 (40 CFR 372).

EPA CERCLA/Superfund Reportable Spill Quantity

Not applicable.

EPA RCRA Hazardous Waste Classification

If product becomes a waste, it does NOT meet the criteria of a hazardous waste as defined by the US EPA.

California Proposition 65 All components listed do not apply to the California Proposition 65 Regulation.

MA Right-to-Know Law Does not apply.

NJ Right-to-Know Law Does not apply.

PA Right-to-Know Law Does not apply.

Canadian Regulations

Canadian DSL Inventory All components listed on inventory or are exempt.

WHMIS Hazard Class Un-Controlled

16. OTHER INFORMATION

The following sections have been revised since the last issue of this MSDS Not applicable

Additional Information For additional information on the use of this product, contact your local Halliburton representative.

For questions about the Material Safety Data Sheet for this or other Halliburton products, contact Chemical Compliance at 1-580-251-4335.

Disclaimer Statement This information is furnished without warranty, expressed or implied, as to accuracy or completeness. The information is obtained from various sources including the manufacturer and other third party sources. The information may not be valid under all conditions nor if this material is used in combination with other materials or in any process. Final determination of suitability of any material is the sole responsibility of the user.

***END OF MSDS***

Disclaimer Statement This information is furnished without warranty, expressed or implied, as to accuracy or completeness. The information is obtained from various sources including the manufacturer and other third party sources. The information may not be valid under all conditions nor if this material is used in combination with other materials or in any process. Final determination of suitability of any material is the sole responsibility of the user.

***END OF MSDS***

N-SEAL™

MATERIAL SAFETY DATA SHEET

Product Trade Name: QUIK-TROL GOLD LV Revision Date: 30-Mar-2012

1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

Product Trade Name: QUIK-TROL GOLD LV Synonyms: None Chemical Family: Carbohydrate Application: Fluid Loss Additive

Manufacturer/Supplier Baroid Fluid Services Product Service Line of Halliburton P.O. Box 1675 Houston, TX 77251 Telephone: (281) 871-4000 Emergency Telephone: (281) 575-5000

Prepared By Chemical Compliance Telephone: 1-580-251-4335 e-mail: fdunexchem@halliburton.com

2. COMPOSITION/INFORMATION ON INGREDIENTS

Substances CAS Number PERCENT ACGIH TLV-TWA OSHA PEL-TWA Polysaccharide 60 - 100% Not applicable Not applicable

3. HAZARDS IDENTIFICATION

Hazard Overview May cause eye, skin, and respiratory irritation. Airborne dust may be explosive.

4. FIRST AID MEASURES

Inhalation If inhaled, remove from area to fresh air. Get medical attention if respiratory irritation develops or if breathing becomes difficult.

Skin Wash with soap and water. Get medical attention if irritation persists.

Eyes In case of contact, immediately flush eyes with plenty of water for at least 15 minutes and get medical attention if irritation persists.

Ingestion Do NOT induce vomiting. Give nothing by mouth. Obtain immediate medical attention.

Notes to Physician Not Applicable

QUIK-TROL GOLD LV

5. FIRE FIGHTING MEASURES

Flash Point/Range (F): Not Determined Flash Point/Range (C): Not Determined Flash Point Method: Not Determined Autoignition Temperature (F): > 698 Autoignition Temperature (C): > 370 Flammability Limits in Air - Lower (%): Not Determined Flammability Limits in Air - Upper (%): Not Determined

Fire Extinguishing Media Water fog, carbon dioxide, foam, dry chemical.

Special Exposure Hazards Organic dust in the presence of an ignition source can be explosive in high concentrations. Good housekeeping practices are required to minimize this potential.

Special Protective Equipment for Fire-Fighters

Full protective clothing and approved self-contained breathing apparatus required for fire fighting personnel.

NFPA Ratings: Health 1, Flammability 1, Reactivity 0 HMIS Ratings: Health 1, Flammability 1, Physical Hazard 0 , PPE: A

6. ACCIDENTAL RELEASE MEASURES

Personal Precautionary MeasuresAvoid creating and breathing dust. Slippery when wet.

Environmental Precautionary Measures

None known.

Procedure for Cleaning / Absorption

Scoop up and remove.

7. HANDLING AND STORAGE

Handling Precautions Avoid contact with eyes, skin, or clothing. Avoid creating or inhaling dust. Avoid dust accumulations. Slippery when wet. Ground and bond containers when transferring from one container to another. Wash hands after use. Launder contaminated clothing before reuse. Do NOT consume food, drink, or tobacco in contaminated areas.

Storage Information Store away from oxidizers. Keep container closed when not in use. Store in a cool, dry location. Store away from direct sunlight. Keep from heat, sparks, and open flames. Store in a well ventilated area. Product has a shelf life of 36 months.

8. EXPOSURE CONTROLS/PERSONAL PROTECTION

Engineering Controls A well ventilated area to control dust levels. Local exhaust ventilation should be used in areas without good cross ventilation.

Personal Protective Equipment If engineering controls and work practices cannot prevent excessive exposures, the selection and proper use of personal protective equipment should be determined by an industrial hygienist or other qualified professional based on the specific application of this product.

Respiratory Protection Not normally needed. But if significant exposures are possible then the following respirator is recommended:

Dust/mist respirator. (95%)

Hand Protection Normal work gloves.

Skin Protection Normal work coveralls.

Eye Protection Wear safety glasses or goggles to protect against exposure.

Other Precautions Eyewash fountains and safety showers must be easily accessible.

9. PHYSICAL AND CHEMICAL PROPERTIES

Physical State: Powder

Color: White to off white Odor: Odorless pH: 5-9 (1%) Specific Gravity @ 20 C (Water=1): Not Determined Density @ 20 C (lbs./gallon): Not Determined Bulk Density @ 20 C (lbs/ft3): 37-56 Boiling Point/Range (F): Not Determined Boiling Point/Range (C): Not Determined Freezing Point/Range (F): Not Determined Freezing Point/Range (C): Not Determined Vapor Pressure @ 20 C (mmHg): Not Determined Vapor Density (Air=1): Not Determined Percent Volatiles: Not Determined Evaporation Rate (Butyl Acetate=1): Not Determined Solubility in Water (g/100ml): Forms gel Solubility in Solvents (g/100ml): Not Determined VOCs (lbs./gallon): Not Determined Viscosity, Dynamic @ 20 C (centipoise): Not Determined Viscosity, Kinematic @ 20 C (centistokes): Not Determined Partition Coefficient/n-Octanol/Water: Not Determined Molecular Weight (g/mole): Not Determined

10. STABILITY AND REACTIVITY

Stability Data: Stable

Hazardous Polymerization: Will Not Occur

Conditions to Avoid None known.

Incompatibility (Materials to Avoid)

Strong oxidizers.

Hazardous Decomposition Products

Carbon monoxide and carbon dioxide.

Additional Guidelines Not Applicable

11. TOXICOLOGICAL INFORMATION

Principle Route of Exposure Eye or skin contact, inhalation.

Inhalation May cause mild respiratory irritation.

Skin Contact May cause mild skin irritation. May cause an allergic skin reaction.

Eye Contact May cause mild eye irritation.

Ingestion May cause allergic reaction.

Aggravated Medical Conditions None known.

Chronic Effects/Carcinogenicity No data available to indicate product or components present at greater than 1% are chronic health hazards.

Other Information None known.

Toxicity Tests

Oral Toxicity: Not determined

Dermal Toxicity: Not determined

Inhalation Toxicity: Not determined

Primary Irritation Effect: Not determined

Carcinogenicity Not determined

Genotoxicity: Not determined

Reproductive / Developmental Toxicity:

Not determined

12. ECOLOGICAL INFORMATION

Mobility (Water/Soil/Air) Not determined

Persistence/Degradability Will not ferment

Bio-accumulation Not determined

Ecotoxicological Information

Acute Fish Toxicity: TLM96: 100-1000 ppm (Lepomis macrochirus) TLM96: 100-1000 ppm (Oncorhynchus mykiss)

Acute Crustaceans Toxicity:Not determined Acute Algae Toxicity: Not determined

Chemical Fate Information Not determined

Other Information Not applicable

13. DISPOSAL CONSIDERATIONS

Disposal Method Disposal should be made in accordance with federal, state, and local regulations.

Contaminated Packaging Follow all applicable national or local regulations.

14. TRANSPORT INFORMATION

Land Transportation

DOT

Not restricted

Canadian TDG Not restricted

ADR

Not restricted

Air Transportation

ICAO/IATA

Not restricted

Sea Transportation

IMDG

Not restricted

Other Transportation Information

Labels: None

15. REGULATORY INFORMATION

US Regulations

US TSCA Inventory All components listed on inventory or are exempt.

EPA SARA Title III Extremely Hazardous Substances

Not applicable

EPA SARA (311,312) Hazard Class

None

EPA SARA (313) Chemicals This product does not contain a toxic chemical for routine annual "Toxic Chemical Release Reporting" under Section 313 (40 CFR 372).

EPA CERCLA/Superfund Reportable Spill Quantity

Not applicable.

EPA RCRA Hazardous Waste Classification

If product becomes a waste, it does NOT meet the criteria of a hazardous waste as defined by the US EPA.

California Proposition 65 All components listed do not apply to the California Proposition 65 Regulation.

MA Right-to-Know Law Does not apply.

NJ Right-to-Know Law Does not apply.

PA Right-to-Know Law Does not apply.

Canadian Regulations

Canadian DSL Inventory All components listed on inventory or are exempt.

WHMIS Hazard Class Un-Controlled

16. OTHER INFORMATION

The following sections have been revised since the last issue of this MSDS Not applicable

Additional Information For additional information on the use of this product, contact your local Halliburton representative.

For questions about the Material Safety Data Sheet for this or other Halliburton products, contact Chemical Compliance at 1-580-251-4335.

Disclaimer Statement This information is furnished without warranty, expressed or implied, as to accuracy or completeness. The information is obtained from various sources including the manufacturer and other third party sources. The information may not be valid under all conditions nor if this material is used in combination with other materials or in any process. Final determination of suitability of any material is the sole responsibility of the user.

***END OF MSDS***

Name Organization Utility Responibility Contact Information Email Address

Richard Kreitler Century Link Telephone 573‐438‐8252 Richard.Kreitler@centurylink cin 828 E High St #14, Potosi, MO 63664

Rusty Rawson National Park Service Water/Sewer 662‐255‐9734 rusty rawson@nps gov 401-, Mark Twain National Forest, 409 Watercress Rd, Van Buren, MO 63965

Bill Smith National Park Service Water/Sewer 573‐300‐6908 bill_smith@nps.gov 401-, Mark Twain National Forest, 409 Watercress Rd, Van Buren, MO 63965

John Walker Ozark Boarder Electric Coop. Electric (573)785‐4631 jwalker@ozarkboarder.org 3281 S Westwood Blvd, Poplar Bluff, MO 63901

Shane Barks USGS Stream Gage 573‐308‐3674 csbarks@usgs.gov 1400 Independence Road, Rolla, MO, 65401