36C25918R0278-00004001.pdf

PDF 50 KB Posted

Attached to
Renovate 3rd Floor at MC - Construction Federal contract opportunity
Solicitation number
36C25918R0278
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19

About this file

36C25918R0278 00004 Table of Contents.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Renovate 3rd Floor at MC - Construction, newest first.
File Type Posted
36C25918R0278-00004020.docx DOCX document
36C25918R0278-00004021.xls XLS spreadsheet
36C25918R0278-00004009.pdf PDF
36C25918R0278-00004005.pdf PDF
36C25918R0278-00004018.pdf PDF
36C25918R0278-00004002.pdf PDF
36C25918R0278-00004016.doc DOC document
36C25918R0278-00004008.pdf PDF
36C25918R0278-00004000.docx DOCX document
36C25918R0278-00004007.pdf PDF
36C25918R0278-00004017.pdf PDF
36C25918R0278-00004012.pdf PDF
36C25918R0278-00004019.pdf PDF
36C25918R0278-00004004.pdf PDF
36C25918R0278-00004003.pdf PDF
36C25918R0278-00004015.doc DOC document
36C25918R0278-00004006.pdf PDF
36C25918R0278-00004014.pdf PDF
36C25918R0278-00004011.pdf PDF
36C25918R0278-00004013.pdf PDF
36C25918R0278-00004010.pdf PDF
36C25918R0278-00003000.docx DOCX document
36C25918R0278-00002000.docx DOCX document
36C25918R0278-00002001.pdf PDF
36C25918R0278-00001000.docx DOCX document
36C25918R0278-006.pdf PDF
36C25918R0278-004.pdf PDF
36C25918R0278-007.pdf PDF
36C25918R0278-013.pdf PDF
36C25918R0278-014.pdf PDF
36C25918R0278-010.pdf PDF
36C25918R0278-001.docx DOCX document
36C25918R0278-012.pdf PDF
36C25918R0278-002.docx DOCX document
36C25918R0278-005.pdf PDF
36C25918R0278-011.pdf PDF
36C25918R0278-009.pdf PDF
36C25918R0278-003.pdf PDF
36C25918R0278-008.pdf PDF
36C25918R0278-000.docx DOCX document
Show all 40

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Grand Junction VAMC May 25, 2018 Elimination of Substandard Beds 3rd floor 100% Construction Documents Grand Junction, CO 81501 Project No. 575-13-101

00 01 10-1

DEPARTMENT OF VETERANS AFFAIRS

VHA MASTER SPECIFICATIONS

TABLE OF CONTENTS

Section 00 01 10

DIVISION 00 - SPECIAL SECTIONS

00 01 15 List of Drawing Sheets

DIVISION 01 - GENERAL REQUIREMENTS

01 00 00 General Requirements

01 32 16.15 Project Schedules (Small Projects – Design/Bid/Build 01 33 23 Shop Drawings, Product Data, and Samples 01 35 26 Safety Requirements 01 42 19 Reference Standards 01 45 00 Quality Control 01 45 29 Testing Laboratory Services 01 57 19 Temporary Environmental Controls 01 58 16 Temporary Interior Signage 01 74 19 Construction Waste Management 01 81 11 Sustainable Design Requirements

DIVISION 02 – EXISTING CONDITIONS

02 06 40 Lead Hazard Control 02 08 10 Asbestos Abatement 02 41 00 Demolition

DIVISION 03 – CONCRETE

03 54 13 Cementitious Self-Leveling Floor Underlayment

DIVISION 04 – MASONRY (NOT USED)

DIVISION 05 – METALS

05 50 00 Metal Fabrications 05 73 00 Ornamental Formed Metal

DIVISION 06 – WOOD,PLASTICS AND COMPOSITES

06 10 00 Rough Carpentry 06 20 00 Finish Carpentry

DIVISION 07 - THERMAL AND MOISTURE PROTECTION

07 21 13 Thermal Insulation 07 84 00 Firestopping 07 92 00 Joint Sealants 07 95 13 Expansion Joint Cover Assemblies

00 01 10-2

DIVISION 08 - OPENINGS

08 11 13 Hollow Metal Doors and Frames 08 14 00 Interior Wood Doors 08 31 13 Access Doors and Frames 08 71 00 Door Hardware 08 81 13 Decorative Glass Glazing 08 90 00 Louvers and Vents

DIVISION 09 – FINISHES

09 05 16 Subsurface Preparation for Floor Finishes 09 06 00 Schedule for Finishes 09 22 16 Non-Structural Metal Framing 09 29 00 Gypsum Board 09 30 13 Ceramic/Porcelain Tiling 09 51 00 Acoustical Ceilings 09 65 13 Resilient Base and Accessories 09 65 19 Resilient Tile Flooring 09 68 00 Carpeting 09 77 20 Fiberglass Reinforced Panels 09 91 00 Painting

DIVISION 10 – SPECIALTIES

10 14 00 Signage 10 21 16 Shower and Dressing Compartments 10 21 23 Cubicle Curtain Tracks 10 25 13 Patient Bed Service Walls 10 25 16 Patient Integral Bed Locations 10 26 00 Wall and Door Protection 10 28 00 Toilet, Bath, and Laundry Accessories 10 44 13 Fire Extinguisher Cabinets

DIVISION 11 – EQUIPMENT

11 73 00 Ceiling Mounted Patient Lift System

DIVISION 12 – FURNISHINGS

12 21 00 Horizontal Louver Blinds 12 32 00 Manufactured Wood Casework 12 35 70.21 Medication Cabinet 12 36 00 Countertops

DIVISION 13 - SPECIAL CONSTRUCTION

13 05 41 Seismic Restraint Requirements for Non-Structural Components

DIVISION 16

16 01 20 Removal of Polychlorinated Biphenyls

DIVISION 21 - FIRE SUPPRESSION

21 05 11 Common Work Results for Fire Suppression

00 01 10-3

21 13 13 Wet-Pipe Sprinkler Systems

DIVISION 22 – PLUMBING

22 05 11 Common Work Results for Plumbing 22 05 19 Meters and Gages for Plumbing Piping 22 05 23 General-Duty Valves for Plumbing Piping 22 07 11 Plumbing Insulation 22 11 00 Facility Water Distribution 22 13 00 Facility Sanitary and Vent Piping 22 40 00 Plumbing Fixtures 22 62 00 Vacuum Systems for Laboratory and Healthcare Facilities 22 63 00 Gas Systems for Laboratory and Healthcare Facilities

DIVISION 23 – HEATING, VENTILATING, AND AIR CONDITIONING

(HVAC)

23 05 11 Common Work Results for HVAC 23 05 12 General Motor Requirements for HVAC and Steam Generation

Equipment 23 05 41 Noise and Vibration Control for HVAC Piping and Equipment 23 05 93 Testing, Adjusting, and Balancing for HVAC 23 07 11 HVAC and Boiler Plant Insulation 23 09 23 Direct-Digital Control System for HVAC 23 21 13 Hydronic Piping 23 22 13 Steam and Condensate Heating Piping 23 31 00 HVAC Ducts and Casings 23 34 00 HVAC Fans 23 36 00 Air Terminal Units 23 37 00 Air Outlets and Inlets

DIVISION 26 – ELECTRICAL

26 05 11 Requirements for Electrical Installations 26 05 19 Low-Voltage Electrical Power Conductors and Cables 26 05 26 Grounding and Bonding for Electrical Systems 26 05 33 Raceway and Boxes for Electrical Systems 26 09 23 Lighting Controls 26 24 16 Panelboards 26 27 26 Wiring Devices 26 29 11 Motor Controllers 26 29 21 Enclosed Switches and Circuit Breakers 26 51 00 Interior Lighting

DIVISION 27 – COMMUNICATIONS

27 05 11 Requirements for Communications Installations 27 05 26 Grounding and Bonding for Communications Systems 27 05 33 Raceways and Boxes for Communications Systems 27 10 00 Structured Cabling 27 11 00 Communications Equipment Room Fittings 27 15 00 Communications Horizontal Cabling 27 41 31 Master Antenna Television Equipment and Systems 27 51 16 Public Address and Mass Notification Systems

00 01 10-4

27 52 23 Nurse Call and Code Blue Systems

DIVISION 28 – ELECTRONIC SAFETY AND SECURITY

28 05 00 Common Work Results for Electronic Safety and Security 28 05 13 Conductors and Cables for Electronic Safety and Security 28 05 26 Grounding and Bonding for Electronic Safety and Security 28 05 28.33 Conduits and Backboxes for Electronic Safety and Security 28 23 00 Video Surveillance 28 31 00 Fire Detection and Alarm

DIVISION 31 – EARTHWORK (NOT USED)

DIVISION 32 – EXTERIOR IMPROVEMENTS (NOT USED)

DIVISION 33 – UTILITIES (NOT USED)

DIVISION 34 – TRANSPORTATION (NOT USED)

DIVISION 48 – Electrical Power Generation (NOT USED)