This federal solicitation package describes a roof replacement project for two buildings at a Department of Veterans Affairs medical center. The contractor will replace roofs on Buildings 1 and 23, including removing and replacing an existing skylight system on Building 1. For Building 1, the contractor must submit a safety plan and be responsible for crane operations and ensuring water tight integrity during skylight replacement. For Building 23, the contractor will remove and store parapet sections, remove the existing roof and insulation, and install a new roof system with insulation and EPDM membrane. The project cost is between $1 million and $2 million. The solicitation is a SDVOSB set-aside with a response due date of May 4, 2020 and an estimated 180-day completion period. The solicitation number is 36C25520R0060 and will be available for download on March 30, 2020 on SAM.gov. Questions can be emailed by the due date to the point of contact listed.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
3 Addendum No: 3 05-14-2020
3 3
Material Spec:
TFP-1 (Kalwall or Equal) 2-3/4” thermally broken grid U-Factor 0.53 Exterior face sheets: Smooth, .070” thick and Crystal in color.
Interior face sheets: Smooth, .045” thick and Crystal in color.
TFP-2 (Kalwall or Equal) 2-3/4” thermally broken grid U-Factor 0.23 Exterior face sheets: Smooth, .070” thick and Crystal in color.
Interior face sheets: Smooth, .045” thick and White in color.
TFP-1 and TFP-2 Thickness: 2-3/4” Light transmission: 16% Solar heat gain coefficient 0.22.
Complete insulated panel system shall have NFRC certified U-factor of 0.30.
Grid pattern: Nominal size 12x20; pattern Shoji.
GL-1 (Viracon of Equal) VZE-48 Exterior face sheets: 1/4" heat strength glass tinted gray Interior face sheets: 2 plies 1/4" laminated together with a .060" interlayer.
Total assemble to meet a minimum SHGC 0.29 and VLT 42%
55'-0"
16'-7"
55'-0"
16'-7"16'-0"
16'-0"