36C24618R0839-011.pdf

PDF 6 MB Posted

Attached to
Project 659-16-103, Replace Campus Fire Alarm System Federal contract opportunity
Solicitation number
36C24618R0839
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6

About this file

36C24618R0839 CONTRACT ATTACHMENT A - DRAWINGS FILE 10 - 10-Sheets_FA144-FA601.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Project 659-16-103, Replace Campus Fire Alarm System, newest first.
File Type Posted
36C24618R0839-0003001.pdf PDF
36C24618R0839-0003000.docx DOCX document
36C24618R0839-0003002.pdf PDF
36C24618R0839-0002000.docx DOCX document
36C24618R0839-0002001.pdf PDF
36C24618R0839-004.pdf PDF
36C24618R0839-013.docx DOCX document
36C24618R0839-008.pdf PDF
36C24618R0839-012.pdf PDF
36C24618R0839-009.pdf PDF
36C24618R0839-001.docx DOCX document
36C24618R0839-014.pdf PDF
36C24618R0839-005.pdf PDF
36C24618R0839-003.pdf PDF
36C24618R0839-010.pdf PDF
36C24618R0839-007.pdf PDF
36C24618R0839-002.pdf PDF
36C24618R0839-006.pdf PDF
36C24618R0839-000.docx DOCX document
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Stair

Stair

Resident

2C128

Resident

2C130

Bath

2C130A

Bath

2C128A

Resident

2C131

Bath

2C131A

Bath

2C127A

Resident

2C127

Bath

2C132A

Bariatric

2C132

Resident

2C126

Bath

2C126A Bath

2C125A

Resident

2C125 Resident

2C124

Bath

2C124A

Living Room

2C121

Meds

2C122

Soiled

2C134

Telecom

2C135

Elec

2C136

Office/ Consult

2C118

Laundry

2C119

Resident

2C117

Bath

2C117A

Break

2C103

Staff Tlt

2C102

Equip

2C104

Passage

2C105HK

2C107

Clean

2C106 Bariatric

2C108

Bath

2C108A

Resident

2C116

Bath

2C116A Bath

2C115A

Resident

2C115 Resident

2C114

Bath

2C114A

Bath

2C109A

Resident

2C109 Resident

2C110

Bath

2C110A

WC/ Stretcher

2C111

WC/ Stretcher

2B155

Resident

2C112 Resident

2C113

Bath

2C113A Bath

2C112A

Formal Dining

Room

2A102 Chute

Vestibule

2A104

Vending

2A105

MATTRESS

STORAGE

2A101

Elec

2A100

Mech

2C133 Pantry

2C100A

Kitchen

2C100

Lounge

2B154

Dining Room

2C120 Nurse Work

2C123

Resident Kitchen

2C101

Resident

2B128

Bath

2B128A

Sitting Area

2B131Living Room

2B132

Meds

2B130 Nurse Work Area

2B129

Soiled

2B105

Elec

2B104 Tele

2B103 Private Dining

2B101

Office/ Consult

2B100

Kichen

2B152 Dining Room

2B150

Pantry

2B151 Resident Kitchen

2B149

Laundry

2B134 Nurse Office

2B133

Resident

2B135

Bath

2B135A

Break

2B148

Equip

2B145

Passage

2B146

Staff Toilet

2B147

Resident

2B136

Bath

2B136A

HK

2B143 Clean

2B144

Resident

2B137 Bath

2B137A

Resident

2B138

Bath

2B138A

Resident

2B139

Bath

2B139A Resident

2B140

Bath

2B140A

Resident

2B142

Bath

2B142A

Resident

2B141

Corridor

C2-19

Bath

2B141A

Room

2B153

Conference Room

2A126B

Conference Room

2A126A

Office

2A121

Toilet

2A122 Toilet

2A123

Office Suite

2A103

GEN STORAGE

2A126C

Tele

2A128

Corridor

C2-16A

Linen

2B146A

Linen

2C105A

Bridge

2E102

Corridor

C2-13

Elevator Lobby

C2-1

Corridor

C2-25

Corridor

C2-26 Corridor

C2-22

Corridor

C2-16

Corridor

C2-20

Elevator

P20

Elevator

P21

Elevator

S23

OFFICE

2A126

UP DN

Stair

Closet

2A101A

Closet

2A102A

Janitor

2A103B

Resident

2D125Bath

2D125A

Soiled

2D134

Elec

2D135 Tele

2D136

Private Dining

2D137Office/

Consult

2D138

Kitchen

2D100

Pantry

2D100A

Meds

2D123

Living Room

2D122

Office/

Consult

2D121 Laundry

2D120

Break

2D103

Equip

2D104

Passage

2D105

Staff Tlt

2D103A Bath

2D119A Resident

2D119

Resident

2D118Bath

2D118A

Resident

2D117 Bath

2D117A

HK

2D107

Clean

2D106

Bariatric

2D108 Bath

2D108A

Resident

2D116 Bath

2D116A Bath

2D109AResident

2D109

Resident

2D110

Bath

2D110A

Resident

2D115 Bath

2D115A

Resident

2D114 Bath

2D114A WC/ Stretcher

2D111

Storage

2C129

Nurse Work

2D124

Sitting Room

2D139

Dining Room

2D101 Resident

Kitchen

2D102

Linen

2D105A

Lounge

2D112

Corridor

C2-31

Corridor

C2-28

Elevator

P24

Vestibule

2D113

FEC-1

MATCHLINE FA144/FA145

MATCHLINE FA144/FA145

MATCHLINE FA144/FA145

MATCHLINE FA144/FA145

HEAT DETECTOR (FIXED)

F F F F F F F F F F

F F

F F F F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F F S

F

F

F

F S

KHFS

KHFS

FAAP

F

HEAT DETECTOR (FIXED)

F

F

F

F

F

F

F

F

F

F

F

F

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S F

S

F S

F S

F S

F S

F S

F S F

S

F S

F S

F S

F S F

S

F S

F S

F S

F S

FS

FS

FS

FS

FS

FS

FS

FS

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F

FS

F S

F S

F S

F S

NACP

DAA

1. AATP REPLACEMENT PANELS SHALL BE CIRCUITED

TO THE SAME CIRCUIT AS THE AATPs.

Drawing Title

Approved for Design Concept:

Project Title

Date

Location

Checked:

Building Number

A/E Project Number

Drawing Number

Drawn:

Revisions: Date

ENGINEERS/ARCHITECT:

W.G. (BILL) HEFNER VAMC

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

OFFICE OF

FACILITIES

MANAGEMENT

VA Project Number

FACILITY MANAGEMENT

DIVISION MANAGER

659-16-103

Architect

PROJECT LEAD

Fire Alarm, Electrical Engineer

VAMC SALISBURY

1601 Brenner Ave, Salisbury, NC 28144

100% CONSTRUCTION DOCUMENTS

SCBRSB11 DEC 2017

15-447REPLACE/UPGRADE CAMPUS

FIRE ALARM SYSTEM

(919) 858-7420 Consulting Group, PA www.acg-pa.com

Raleigh, NC Indianapolis, IN Philadelphia, PA Pittsburgh, PA Virginia Beach, VA Fort Collins, CO GURLITZ

ARCHITECTURAL

23894

SEAL

FA144

BLDG 42 SECOND FLOOR EAST

1 BLDG 42 SECOND FLOOR EAST

3/32"= 1'

HEALTH CARE OCCUPANCY - FULLY SPRINKLERED

GENERAL NOTES

ELECTRICAL POWER NOTES

1. REPLACE ALL EXISTING DUCT DETECTORS AND

ASSOCIATED KEY SWITCHES. NEW KEY SWITCH

LOCATION SHALL BE ACCESSIBLE, WITH HEIGHT

ACCORDING TO NOTES AND SPECIFICATIONS.

2. WHERE NEW DEVICES ARE SHOWN, LOCATE THE

NEAREST JUNCTION BOX WITH THE SLC, NAC,

OR SPEAKER CIRCUIT AND INTERCEPT AND

EXTEND CIRCUIT TO THE NEW DEVICE

LOCATION.

3. VERIFY ALL CEILING TYPES BEFORE WORK.

REPLACE ANY CEILING DAMAGE AND PAINT TO

MATCH EXISTING.

4. ALL EXISTING DEVICES TO REMAIN. PROVIDE

NEW DEVICES AS SHOWN. CONNECT OLD

CIRCUITS AND NEW CIRCUITS TO NEW FACP.

DocuSign Envelope ID: 94B147EA-25A3-4143-9BDC-8EC43B57B4A8

6/25/2018

Closet

2A120 Office

2A119

Office

2A118

Office

2A117

Office

2A116

Stair

GM Breakroom

2A106

Supply Closet

2A111 Office

2A112

Office

2A113

Office

2A114

Office

2A115

Copy Room

2A110

Men's Locker/

Toilet

2A109

Women's Locker/

Toilet

2A107

Room

2A108

Vending

2A105

Resident

2B109

Resident

2B110

Bath

2B109A

Bath

2B110A

Elec

2B111 Mechanical

2B112Corridor

C2-42

Equip

2B113

Equip

2B114

Bath

2B115A

Corridor

C2-44Bath

2B122A Bath

2B121A

Bath

2B120A Bath

2B119A

Bath

2B118A

Bath

2B117A

Bath

2B116A

Lounge

2B123 Corridor

C2-43

Corridor

C2-17 Storage

2B107A Snoezelen Room

2B107

Corridor

C2-41

Mechanical

2B106

Bath

2B124A

Resident

2B124

Resident

2B125 Bath

2B125A

Resident

2B126

Bath

2B126A

Bath

2B127A

Resident

2B127

Resident

2B128

Bath

2B128A

Meds

2B130 Nurse Work Area

2B129

Soiled

2B105

Elec

2B104 Tele

2B103 Private Dining

2B101

Office/ Consult

2B100

Mechanical

2A124

Office

2A121

Toilet

2A122 Toilet

2A123

Elevator Lobby

C2-1

Stair

Stair

Resident

2B120

Resident

2B121

Resident

2B122 Resident

2B115

Resident

2B116

Resident

2B117

Resident

2B119

Resident

2B118

Corridor

C2-7

Corridor

C2-8

Corridor

C2-9

Waiting

C2-5

Secretary

C2-6

Corridor

C2-2

Secretary

C2-4 Lobby

C2-3

Elevator

P20

Elevator

P21

DN

Stair

Bariatric

2D132

Bath

2D132A

Bath

2D131A Resident

2D131

Resident

2D130 Bath

2D130A

Resident

2D129Bath

2D129A

Resident

2D128Bath

2D128A

Resident

2D127 Bath

2D127A

Bath

2D126A Resident

2D126

Resident

2D125Bath

2D125A

Mechanical

2D133

Soiled

2D134

Elec

2D135 Tele

2D136

Private Dining

2D137Office/

Consult

2D138

Meds

2D123

2D122

Nurse Work

2D124

Corridor

C2-32

FEC-1

MATCHLINE FA144/FA145

MATCHLINE FA144/FA145

MATCHLINE FA144/FA145

MATCHLINE FA144/FA145

F

F

F

F

F

F

F

F

F

F

F F

F

F

F

F

F

F

F

F S

F S

F S

F

F

NACP

NACP

FAAP

F

F

F

F

F

F

F

F

F

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

FS

FS

FS

F S

F S

F S

F S

FS

FS

FS

FS

FS

FS

FS

FS

FS

FS

F S

F S

FS

FS

F S

F S

F S

F S

F S

F S

F S

F S

F S F

S F S

FS

FF

F

F S

F S

F

FS

F S

FA122

TO B

LD

G 6

NACP

DAA

1. AATP REPLACEMENT PANELS SHALL BE CIRCUITED

TO THE SAME CIRCUIT AS THE AATPs.

Drawing Title

Approved for Design Concept:

Project Title

Date

Location

Checked:

Building Number

A/E Project Number

Drawing Number

Drawn:

Revisions: Date

ENGINEERS/ARCHITECT:

W.G. (BILL) HEFNER VAMC

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

OFFICE OF

FACILITIES

MANAGEMENT

VA Project Number

FACILITY MANAGEMENT

DIVISION MANAGER

659-16-103

Architect

PROJECT LEAD

Fire Alarm, Electrical Engineer

VAMC SALISBURY

1601 Brenner Ave, Salisbury, NC 28144

100% CONSTRUCTION DOCUMENTS

SCBRSB11 DEC 2017

15-447REPLACE/UPGRADE CAMPUS

FIRE ALARM SYSTEM

(919) 858-7420 Consulting Group, PA www.acg-pa.com

Raleigh, NC Indianapolis, IN Philadelphia, PA Pittsburgh, PA Virginia Beach, VA Fort Collins, CO GURLITZ

ARCHITECTURAL

23894

SEAL

FA145

BLDG 42 SECOND FLOOR WEST

1 BLDG 42 SECOND FLOOR WEST

3/32"= 1'

HEALTH CARE OCCUPANCY - FULLY SPRINKLERED

GENERAL NOTES

#KEYED NOTES

ELECTRICAL POWER NOTES

1. REPLACE AATP (NOTIFIER XPIQ) WITH A NACP

AND DAA. RECONFIGURE NAC AND SPEAKER

CIRCUITS AS REQUIRED.

1. REPLACE ALL EXISTING DUCT DETECTORS AND

ASSOCIATED KEY SWITCHES. NEW KEY SWITCH

LOCATION SHALL BE ACCESSIBLE, WITH HEIGHT

ACCORDING TO NOTES AND SPECIFICATIONS.

2. WHERE NEW DEVICES ARE SHOWN, LOCATE THE

NEAREST JUNCTION BOX WITH THE SLC, NAC,

OR SPEAKER CIRCUIT AND INTERCEPT AND

EXTEND CIRCUIT TO THE NEW DEVICE

LOCATION.

3. VERIFY ALL CEILING TYPES BEFORE WORK.

REPLACE ANY CEILING DAMAGE AND PAINT TO

MATCH EXISTING.

4. ALL EXISTING DEVICES TO REMAIN. PROVIDE

NEW DEVICES AS SHOWN. CONNECT OLD

CIRCUITS AND NEW CIRCUITS TO NEW FACP.

PLAY ROOM

MEDITATION

GAME ROOM

FAMILY ROOM

EQUIPEMENT

BREAK RM

PHY OFF

NP OFF

COORD OFF

NUR MGR OFF

SW OFF

FLEX OFF

WELCOME CTR.

DINING ROOM

VESTIBULE

LOBBY

KITCHEN

FAMILY KITCHEN

SOILED UTILITY

HK

FAM SUITE

116A

FAM BATH

NURSE

CORR

CLEAN SUP

TELECOM

MEDS

MECHANICAL

EM ELECT

NORM ELEC

CHAPLAIN

EQUIP. STORAGE

CORR

12B

BATH

QUIET RM

PASSAGE

66 146

LAUNDRY

NURSE

PASSAGE

BATHTIQUE

TLT

TLT

TLT

PASSAGE

TLT

TLT

OFFICE

RESIDENT ROOM

RESIDENT ROOM

RESIDENT ROOM

RESIDENT ROOM

RESIDENT ROOM

RESIDENT ROOM

11B

BATH

10B

BATH

9B

BATH

8B

BATH

7B

BATH

ELECTRICAL CLT

LIVING ROOM

783 104

CORR

NURSE

CORR

CORR

RESIDENT ROOM

6B

BATH

RESIDENT ROOM

RESIDENT ROOM

RESIDENT ROOM

RESIDENT ROOM

RESIDENT ROOM

5B

BATH

4B

BATH

3B

BATH

2B

BATH

1B

BATH

PASS

CORR

MECHANICAL

KENNEL

SECURITY CLOSET

115A

LINENS

Corr

124 BUILDING 42

FACP

NACP

TO BLDG 42FIBER

PLAY ROOM

MEDITATION

GAME ROOM

FAMILY ROOM

EQUIPEMENT

BREAK RM

PHY OFF

NP OFF

COORD OFF

NUR MGR OFF

SW OFF

FLEX OFF

WELCOME CTR.

DINING ROOM

VESTIBULE

LOBBY

KITCHEN

FAMILY KITCHEN

SOILED UTILITY

HK

FAM SUITE

116A

FAM BATH

NURSE

CORR

CLEAN SUP

TELECOM

MEDS

MECHANICAL

EM ELECT

NORM ELEC

CHAPLAIN

EQUIP. STORAGE

CORR

12B

BATH

QUIET RM

PASSAGE

66 146

LAUNDRY

NURSE

PASSAGE

BATHTIQUE

TLT

TLT

TLT

PASSAGE

TLT

TLT

OFFICE

RESIDENT ROOM

RESIDENT ROOM

RESIDENT ROOM

RESIDENT ROOM

RESIDENT ROOM

RESIDENT ROOM

11B

BATH

10B

BATH

9B

BATH

8B

BATH

7B

BATH

ELECTRICAL CLT

LIVING ROOM

783 104

CORR

NURSE

CORR

CORR

RESIDENT ROOM

6B

BATH

RESIDENT ROOM

RESIDENT ROOM

RESIDENT ROOM

RESIDENT ROOM

RESIDENT ROOM

5B

BATH

4B

BATH

3B

BATH

2B

BATH

1B

BATH

PASS

CORR

MECHANICAL

KENNEL

SECURITY CLOSET

115A

LINENS

Corr

124 BUILDING 42

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F F

F

FF

F

F

F

F

FA

C

P

FA

A

P

FAAP

FAAP

Fco

Fco

Fco

N A

C P

KHFS

FS

FS

FS

FS

FS

FS

FS

FS

FS

FS

FS

FS

FS

FS

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

F S

FS

F S

F S

F S

F S

FS

FS

F

F

F

F

F

F

FS

1. WHERE NEW DEVICES ARE SHOWN, LOCATE THE

NEAREST JUNCTION BOX WITH THE SLC, NAC, OR

SPEAKER CIRCUIT AND INTERCEPT AND EXTEND

CIRCUIT TO THE NEW DEVICE LOCATION.

2. PROVIDE NEW FIBER PATCH PANEL AND

CONNECTIONS FOR FACP.

3. VERIFY ALL CEILING TYPES BEFORE WORK. REPLACE

ANY CEILING DAMAGE AND PAINT TO MATCH

EXISTING.

4. ALL EXISTING DEVICES TO REMAIN. PROVIDE NEW

DEVICES AS SHOWN. CONNECT OLD CIRCUITS AND

NEW CIRCUITS TO NEW FACP.

Drawing Title

Approved for Design Concept:

Project Title

Date

Location

Checked:

Building Number

A/E Project Number

Drawing Number

Drawn:

Revisions: Date

ENGINEERS/ARCHITECT:

W.G. (BILL) HEFNER VAMC

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

OFFICE OF

FACILITIES

MANAGEMENT

VA Project Number

FACILITY MANAGEMENT

DIVISION MANAGER

659-16-103

Architect

PROJECT LEAD

Fire Alarm, Electrical Engineer

VAMC SALISBURY

1601 Brenner Ave, Salisbury, NC 28144

100% CONSTRUCTION DOCUMENTS

SCBRSB11 DEC 2017

15-447REPLACE/UPGRADE CAMPUS

FIRE ALARM SYSTEM

(919) 858-7420 Consulting Group, PA www.acg-pa.com

Raleigh, NC Indianapolis, IN Philadelphia, PA Pittsburgh, PA Virginia Beach, VA Fort Collins, CO GURLITZ

ARCHITECTURAL

23894

SEAL

FA146

BLDG 43

1 BLDG 43

3/32"= 1'

HEALTH CARE OCCUPANCY - FULLY SPRINKLERED

GENERAL NOTES

#KEYED NOTES

1. PROVIDE FIBER BOX, PATCH PANEL, PATCH

CORDS AND RELATED MATERIAL. SEE DETAILS

ON FA501 FOR MORE INFO.

2. EXTEND ALL CKT TO NEW NACP & FACP.

BUILDING FLOOR

BUILDING WALL

HDPE CONDUIT

BY DIRECTIONAL BORE

PULL BACK CONDUIT

DIRECTLY FROM

CRAWLSPACE

SUPPORT ARMORED FIBER TO

STRUCTURE EVERY 54" MIN

(TIE SECURELY - DO NOT LAY LOOSE)

CONDUIT SHALL BE SUPPORTED TO

STRUCTURE IN TWO PLACES MINIMUM

ARMORED

FIBER CABLE

FLOOR JOISTS/FRAMING

(TYP)

WHERE CRAWLSPACE BECOMES

INACCESSIBLE TO INSTALL

SUPPORTS, ARMORED FIBER CABLE

SHALL BE FISHED ALONG GRADE GRADE

PROVIDE SUFFICIENT SLACK WHILE PULLING TO

PREVENT EXCEEDING MINIMUM CABLE IN-USE RADIUS

CABLE

SUPPORT (TYP)

FIBER CRAWLSPACE INSTALLATION NOTES

1. ARMORED FIBER CABLE SHALL BE INSTALLED IN MIN

1-1/2" CONDUIT OR PER 2014 NEC 350.30.

2. WHERE NOT INSTALLED IN CONDUIT, ARMORED FIBER

CABLE SHALL BE SUPPORTED EVERY 54" MINIMUM OR

SHALL BE CONTINUOUSLY SUPPORTED BY UNISTRUT

SPANNING STRUCTURAL MEMBERS.

3. WHEN PASSING ARMORED FIBER CABLE THROUGH

INACCESSIBLE SPACES, CABLE MAY BE FISHED ALONG

GROUND.

PROVIDE FIRE-RATED CONDUIT PENETRATION

THROUGH FLOOR OR WALL. WHERE EXPOSED,

ARMORED FIBER CABLE SHALL CONTINUE IN MIN

1-1/2" CONDUIT TO DESTINATION

POLYMER CONCRETE

UNDERGROUND ENCLOSURE

(HAND HOLE)

6" MIN

LID LABELED 'SIGNAL'

PVC OR HDPE CONDUIT

CONNECTOR

RIGID PVC CONDUIT ELBOW (MIN RADIUS

PER NEC OR MINIMUM CABLE INSTALLATION

BEND RADIUS, WHICHEVER IS GREATER)

PROVIDE 5% GRADE

MIN 36" ON ALL SIDES

4" MIN

6" MIN

COMPACTED BACKFILL

#5-7 STONE

STUB UP MIN 2" ABOVE GRAVEL.

SEAL WITH NON-HARDENING DUCT SEAL TO

PREVENT GRAVEL FROM ENTERING CONDUIT.

ARMORED FIBER

MC CABLE CONNECTOR

NIPPLE TO FIRE

ALARM EQUIPMENT

FIRE ALARM EQUIPMENT

DOUBLE-DOOR WALL MOUNT

FIBER OPTIC PATCH PANEL,

PANDUIT OPTICOM FWME4 OR

EQUAL. FACTORY-PAINTED RED.

PROVIDE LOCK; KEY TO FIRE

ALARM PANEL KEY. FIBER PATCH CORDS

ALL STRANDS SHALL BE

TERMINATED ON THE

FIBER COUPLERS IN THE

FIBER PATCH PANEL

CONNECTION TO FIBER CARD

PROVIDE ADDITIONAL PATCH

CORDS TO CONNECT

ADDITIONAL CARDS.

LOOP 48" MIN.

TIE OR CLIP TO PREVENT UNWINDING.

DO NOT REMOVE OUTER JACKET UNTIL

AFTER WINDING.

NOTES:

1. ALL CABLES SHALL BE NEATLY DRESSED.

2. EACH FIBER-CONNECTED EQUIPMENT LOCATION

SHALL BE PROVIDED WITH A WALL-MOUNTED PATCH

PANEL. EXISTING PANELS RECEIVING NEW FIBER

CONNECTION SHALL BE PROVIDED WITH A NEW

PATCH PANEL.

3. WHERE FIBER-CONNECTED FIRE ALARM EQUIPMENT

IS SEPARATED BY GREATER THAN 6', A SEPARATE

PATCH PANEL AND TWO SEGMENTS OF ARMOR

FIBER SHALL BE PROVIDED.

WHERE EXPOSED, ARMORED FIBER

SHALL BE ROUTED IN CONDUIT

PROVIDE LOOP PRIOR TO

EACH TERMINATION

FASTEN LOOP SECURELY

ARMORED FIBER SHALL EXIT CONDUIT

PRIOR TO CONNECTION TO CABINET

(EXPOSED 6" MAX)

WHERE INSTALLED ABOVE CEILING,

ARMORED FIBER MAY BE WITHOUT CONDUIT.

SUPPORT PER 2014 NEC 350.30

LOCATE LOOP ABOVE CEILING OR

BELOW FLOOR (IN CRAWLSPACE)

WHERE PRACTICABLE.

LOCATE LOOP ABOVE CEILING OR

BELOW FLOOR (IN CRAWLSPACE)

WHERE PRACTICABLE.

CEILING

FLOOR

FIBER PATCH PANEL (TYP)

FIRE ALARM EQUIPMENT (TYP)

ARMORED FIBER MAY

EXIT CONDUIT AT

MINIMUM DISTANCE

REQUIRED TO SATISFY

IN-USE BEND RADIUS

CONTINUE TO NEXT

FIRE ALARM EQUIPMENT

CONTINUE TO NEXT

FIRE ALARM EQUIPMENT

CEILING

FLOOR

WHERE ARMORED FIBER

MUST BE EXPOSED IN

ACCESSIBLE AREA,

SECURELY SUPPORT

EVERY 6" MIN

UNDER NO CIRCUMSTANCES SHALL

ARMORED FIBER RISE THROUGH

FLOOR WITHOUT CONDUIT.

1. PROVIDE SLACK LOOPS ACCORDING TO THE FOLLOWING:

1.1. MAINTAIN MANUFACTURER'S RECOMMENDED

MINIMUM IN-USE BEND RADIUS FOR ALL LOOPS

AND TURNS INTO EQUIPMENT.

1.2. EACH LOOP SHALL BE TIED AND SUPPORTED

SECURELY. SUPPORTS AND TIES IN UNDERGROUND

ENCLOSURES SHALL BE NON-CORROSIVE.

1.3. LOOPS SHALL BE CONCEALED OR OUT-OF-REACH

WHERE PRACTICABLE.

1.4. FOR EACH SEGMENT OF ARMORED FIBER RUN,

PROVIDE 5% OF THE LENGTH OF THE RUN IN LOOPS

(5' LOOP FOR EVERY 100' RUN), WITH MIN 10' LOOP

PRIOR TO EACH TERMINATION, WHICHEVER IS

GREATER. LOOPS EVERY 500' MIN. PROVIDE

ADDITIONAL BOXES IF REQUIRED.SUBMIT

PROPOSED LOOP LOCATIONS AND LENGTHS.

2. UNLESS OTHERWISE NOTED ALL ABOVE-GROUND

CONDUIT, BOXES, AND COVERS SHALL BE RED. EXISTING

CONDUIT SHALL BE USED IN-PLACE, BUT THEY SHALL BE

PAINTED RED. (REMOVED CONDUIT SHALL NOT BE

RE-INSTALLED.)

3. ARMORED FIBER OUTER JACKET SHALL BE RED.

4. INSTALLATION BY LOCATION SHALL BE AS FOLLOWS:

4.1. ABOVE CEILINGS:

4.1.1. ARMORED FIBER SHALL BE INSTALLED IN 1-1/2"

CONDUIT OR INSTALLED PER 2014 NEC 350.30.

4.1.2. WHERE INSTALLED PER 2014 NEC 350.30,

ARMORED CABLE SHALL BE SECURELY

SUPPORTED TO STRUCTURE OR

CONSTRUCTED SUPPORT. ARMORED FIBER

SHALL NOT BE SUPPORTED BY PIPING,

CONDUIT, OR DUCT AND SHALL NOT BE LAID

ON CEILING TILE.

4.2. OPEN AND EXPOSED CEILINGS:

4.2.1. ARMORED FIBER SHALL BE INSTALLED IN 1-1/2"

CONDUIT.

4.2.2. IN FINISHED AREAS, CONDUIT AND BOXES

SHALL BE PAINTED TO MATCH CEILING.

4.2.3. IN INDUSTRIAL TYPE AND UNFINISHED AREAS

(SUCH AS MECHANICAL ROOMS, ELECTRICAL

ROOMS, AND TELCO ROOMS.) CONDUIT,

BOXES, AND COVERS SHALL BE RED.

4.3. EXISTING RACEWAYS:

4.3.1. WHERE INSTALLED IN EXISTING RACEWAYS

SHARED BY OTHER SYSTEMS, THE RACEWAY

SHALL NOT BE PAINTED RED.

4.3.2. AT EACH PULL POINT, AN EMBOSSED OR

ENGRAVED METAL IDENTIFICATION TAG WHICH

READS "FIRE ALARM" SHALL BE TIED TO THE

FIRE ALARM FIBER CABLE.

4.4. NEW UNDERGROUND RACEWAYS:

4.4.1. SHALL BE BY DIRECTIONAL BORE OR OTHER

APPROVED MEANS. HAND HOLES SHALL BE

PROVIDED AS REQUIRED TO ENSURE PULLING

TENSION DOES NOT EXCEED THAT

RECOMMENDED BY THE MANUFACTURER. SEE

HAND HOLE DETAIL.

4.4.2. CONDUIT SIZE AND QUANTITY SHALL BE AS

INDICATED ON SITE PLAN.

4.4.3. IN EACH MAN HOLE OR HAND HOLE, USE

NON-CORROSIVE WIRE TO TIE EMBOSSED OR

ENGRAVED NON-CORROSIVE METAL TAG TO

ARMORED FIBER. FOR MAN HOLES, PROVIDE

TWO TAGS PER FIBER SEGMENT, LOCATED AT

EACH CONDUIT ENTRY. FOR HAND HOLES,

PROVIDE ONE TAG.

4.4.4. WHERE BORING INTO CRAWLSPACE, SEE

CRAWLSPACE INSTALLATION DETAIL.

4.5. CRAWLSPACES:

4.5.1. SEE CRAWLSPACE INSTALLATION DETAIL.

5. IN ALL CASES WHERE FIBER IS INSTALLED BELOW 8' AFF

AND EXPOSED, FIBER SHALL BE INSTALLED IN CONDUIT.

6. WHERE TWO SEGMENTS OF FIBER CABLE FOLLOW THE

SAME ROUTE THROUGH A BUILDING OR TUNNEL, THEY

SHALL BE PHYSICALLY SEPARATED BY 36" MIN. WHERE

36" IS NOT POSSIBLE, MAINTAIN AS MUCH PHYSICAL

SEPARATION AS POSSIBLE.

7. SUBMIT FIBER ROUTE AND RACEWAY TYPE AND COLOR

FOR EACH AREA.

8. ALL FIBER CABLING ROUTED THROUGH WALLS OR

FLOORS SHALL BE PROVIDED WITH A CONDUIT SLEEVE.

9. PROVIDE FIRE STOPPING FOR ALL SLEEVES.

10. PROVIDE 25' FIBER LOOP EVERY 400'.

FIBER INSTALLATION NOTES

Drawing Title

Approved for Design Concept:

Project Title

Date

Location

Checked:

Building Number

A/E Project Number

Drawing Number

Drawn:

Revisions: Date

ENGINEERS/ARCHITECT:

W.G. (BILL) HEFNER VAMC

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

OFFICE OF

FACILITIES

MANAGEMENT

VA Project Number

FACILITY MANAGEMENT

DIVISION MANAGER

659-16-103

Architect

PROJECT LEAD

Fire Alarm, Electrical Engineer

VAMC SALISBURY

1601 Brenner Ave, Salisbury, NC 28144

100% CONSTRUCTION DOCUMENTS

SCBRSB11 DEC 2017

15-447REPLACE/UPGRADE CAMPUS

FIRE ALARM SYSTEM

(919) 858-7420 Consulting Group, PA www.acg-pa.com

Raleigh, NC Indianapolis, IN Philadelphia, PA Pittsburgh, PA Virginia Beach, VA Fort Collins, CO GURLITZ

ARCHITECTURAL

23894

SEAL

1 ARMORED FIBER TYPICAL INSTALLATION

NTS

FA-501

DETAILS

2 PATCH PANEL INSTALLATION

NTS4 TYPICAL CRAWLSPACE ARMORED FIBER INSTALLATION

NTS

3 TYPICAL HAND HOLE INSTALLATION

NTS

TO ADDITIONAL

SPRINKLER DEVICES

TO ADDITIONAL

INITIATING

DEVICES

TO SMOKE DAMPERS

NEW

FIRE ALARM

CONTROL

PANEL (FACP)

DACT

SPRINKLER FLOW AND

TAMPER SWITCH DEVICES

TO ADDITIONAL FIRE

ALARM SPEAKERS

CONTROL RELAY

FOR AUTO DOORS

(TYPICAL)

FIRE ALARM RISER NOTES

1. FIRE ALARM SYSTEM SHALL BE INTERCONNECTED WITH ACCESS CONTROL SYSTEM TO

ALLOW EGRESS DURING ALARM CONDITIONS. COORDINATE BETWEEN ACCESS CONTROL

SYSTEM AND FIRE ALARM SYSTEM MANUFACTURERS.

2. ALL FIRE ALARM WIRING SHALL BE IN FACTORY PAINTED RED CONDUIT.

3. ALL WIRING SHALL BE AS RECOMMENDED BY MANUFACTURER.

4. PROVIDE SEPARATE OUTPUT SIGNALS TO AIR HANDLER UNIT CONTROLLER FOR

INDIVIDUAL UNIT SHUT-DOWN.

5. PROVIDE ZONE ADAPTER MODULES TO CONNECT NON-ADDRESSABLE DEVICES SUCH AS

FLOW AND TAMPER SWITCHES, DOOR HOLD-OPEN DEVICES, AND CONTROL SIGNALS.

6. PROVIDE POWER SUPPLY AND/OR NAC (NOTIFICATION APPLIANCE CIRCUIT) PANEL AS

REQUIRED FOR ADDITIONAL DEVICES.

7. PROVIDE POWER AMPLIFIERS FOR ALL SPEAKERS.

8. THE NEW FIRE ALARM SYSTEM SHALL MATCH THE EXISTING NOTIFIER FIRE ALARM

SYSTEM, FUNCTIONS, OPERATIONS, AND PROGRAMMING.

9. PROVIDE ADDRESSABLE RELAY MODULES FOR:

A. ELEVATOR PRIMARY RECALL

B. ELEVATOR ALTERNATE RECALL

C. IN CAB NOTIFICATIONS

10. PROVIDE ADDRESSABLE CONTROL MODULES FOR:

A. ELEVATOR EMERGENCY SHUNT TRIP

11. PROVIDE ADDRESSABLE INTERFACE MODULES FOR:

A. ELEVATOR EMERGENCY SHUNT TRIP POWER SUPERVISION

SECURITY

SYSTEM

INTERCONNECT

FIRE ALARM

SYSTEM REMOTE

ANNUNCIATOR NEW

FIRE

ALARM

PANEL

NAC

PANEL

TO

ADDITIONAL

FIRE

ALARM

DEVICES

TO ADDITIONAL

INDICATING

APPLIANCES

TO ADDITIONAL DOOR

HOLDER DEVICES

EPR

TO ADDITIONAL

ELEVATOR RECALLS

F S

F S

F S

FIBER

ELEVATOR RECALL DEVICES

F S

F

NETWORK

COMMAND

CONSOLE

KITCHEN HOOD

F

EPR

12. PROVIDE COPPER BUILDING ENTRANCE PROTECTION FOR ALL CABLING ENTERING AND

EXISTING THE BUILDING PER MANUFACTURERS RECOMMENDATION.

EXISTING

FACP

NEW FB

FIBER

FIBER BOX

FACP-18

17C 17B 17A

FACP-21A

21B

FACP-11A

11B

11C

FACP-14E

14W

SLC-LOOP,

NAC CIRCUIT, AND/OR

SPEAKER CIRCUIT

(TYP)

FACP-21

FACP-05

NACP-31

NACP

NACP

EXISTING FACP

NEW

FIBER BOX

TO EXISTING

DEVICE

TO EXISTING

DEVICE

NEW 12

STRAND

FIBER

FANCC-04

FACP-13

FACP-04 FACP-19

FACP-01

FANA-12

FACP-14E

FACP-02

FACP-03

FACP-09

FACP-20

FACP-05

FACP-06

FACP-42 FACP-43FACP-07FACP-18 FANA-18

FACP-15

FACP-11A

FACP-11

FACP-08

FACP-21AFANA-21

FACP-21

NOTES:

1. EACH LINE REPRESENTS 12-STRAND INDOOR/OUTDOOR ARMORED FIBER-OPTIC CABLING.

TWO STRANDS ARE FOR CONNECTION TO THE FIRE ALARM EQUIPMENT, 10 ARE SPARE.

2. RACEWAY TYPE AND RUN DISTANCES PRESENTED HERE ARE APPROXIMATE AND FOR

REFERENCE ONLY. CONTRACTOR SHALL DETERMINE EXACT ROUTING, RACEWAY TYPE,

AND INSTALLATION METHODS REQUIRED FOR ALL FIBER-OPTIC CABLING.

3. SEE SITE PLAN AND BUILDING PLANS FOR ROUTING.

4. NO ALTERATION TO LOOP ARRANGEMENT IS PERMITTED WITHOUT PRIOR APPROVAL BY

THE ENGINEER AND THE VA.

5. SEE DETAILS ON FA501 FOR FIBER BOXES, PATCH PANELS & SELECTED MATERIAL FOR

EACH FIRE ALARM PANEL.

Drawing Title

Approved for Design Concept:

Project Title

Date

Location

Checked:

Building Number

A/E Project Number

Drawing Number

Drawn:

Revisions: Date

ENGINEERS/ARCHITECT:

W.G. (BILL) HEFNER VAMC

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

OFFICE OF

FACILITIES

MANAGEMENT

VA Project Number

FACILITY MANAGEMENT

DIVISION MANAGER

659-16-103

Architect

PROJECT LEAD

Fire Alarm, Electrical Engineer

VAMC SALISBURY

1601 Brenner Ave, Salisbury, NC 28144

100% CONSTRUCTION DOCUMENTS

SCBRSB11 DEC 2017

15-447REPLACE/UPGRADE CAMPUS

FIRE ALARM SYSTEM

(919) 858-7420 Consulting Group, PA www.acg-pa.com

Raleigh, NC Indianapolis, IN Philadelphia, PA Pittsburgh, PA Virginia Beach, VA Fort Collins, CO GURLITZ

ARCHITECTURAL

23894

SEAL

FA-601

FIBER INTERCONNECTION DIAGRAM

1 FIRE ALARM TYPICAL RISER DIAGRAM

NTS

3 COPPER INTERCONNECTION DIAGRAM (NACP)

NTS

5 EXISTING FIRE ALARM TYPICAL RISER

NTS

MATRIX NOTES:

1. NEW EQUIPMENT = N

2. EXISTING TO REMAIN = E

3. NOTE A: FED FROM BLDG 5

4. NOTE B= FED FROM BLDG 11A

5. NOTE C= FED FROM BLDG 14E

6. NOTE D= FED FROM BLDG 17

7. NOTE E1= FED FROM BLDG 18

8. NOTE F= FED FROM BLDG 21A

9. NOTE G= NEW FIBER CABLES,

PATCH PANELS, FIBER BOXES,

PATCH CORDS, TERMINATIONS,

CONNECTION & TESTING.

4 BUILDING-CAMPUS ALARM MATRIX

NTS

2 FIBER INTERCONNECTION DIAGRAM

NTS

6 FIRE ALARM MATRIX

NTS

15-447-FA143 B42F1 East, West-FA143.pdf
Sheets and Views
FA143
15-447-FA601 FIBER INTERCONNECTION-FA601.pdf
Sheets and Views
FA601
15-447-FA501 DETAILS-FA501.pdf
Sheets and Views
FA501
15-447-FA146 B43-FA146.pdf
Sheets and Views
FA146
15-447-FA145 B42F2 East, West-FA145.pdf
Sheets and Views
FA145
15-447-FA144 B42F2 East, West-FA144.pdf
Sheets and Views
FA144
15-447-FA144 B42F2 East, West-FA144.pdf
Sheets and Views
FA144
2018-06-26T04:52:41-0700
DocuSign, Inc.
Digitally verifiable PDF exported from www.docusign.com

File details come from the government source that posted it.