36C24618R0839-006.pdf
PDF 3 MB Posted
- Attached to
- Project 659-16-103, Replace Campus Fire Alarm System Federal contract opportunity
- Solicitation number
- 36C24618R0839
About this file
36C24618R0839 CONTRACT ATTACHMENT A - DRAWINGS FILE 5 - 05-Sheets_FD144-FD601.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24618R0839-0003001.pdf | ||
| 36C24618R0839-0003000.docx | DOCX document | |
| 36C24618R0839-0003002.pdf | ||
| 36C24618R0839-0002000.docx | DOCX document | |
| 36C24618R0839-0002001.pdf | ||
| 36C24618R0839-004.pdf | ||
| 36C24618R0839-013.docx | DOCX document | |
| 36C24618R0839-008.pdf | ||
| 36C24618R0839-012.pdf | ||
| 36C24618R0839-009.pdf | ||
| 36C24618R0839-005.pdf | ||
| 36C24618R0839-003.pdf | ||
| 36C24618R0839-010.pdf | ||
| 36C24618R0839-007.pdf | ||
| 36C24618R0839-011.pdf | ||
| 36C24618R0839-001.docx | DOCX document | |
| 36C24618R0839-014.pdf | ||
| 36C24618R0839-002.pdf | ||
| 36C24618R0839-000.docx | DOCX document |
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Stair
Stair
Resident
2C128
Resident
2C130
Bath
2C130A
Bath
2C128A
Resident
2C131
Bath
2C131A
Bath
2C127A
Resident
2C127
Bath
2C132A
Bariatric
2C132
Resident
2C126
Bath
2C126A Bath
2C125A
Resident
2C125 Resident
2C124
Bath
2C124A
Living Room
2C121
Meds
2C122
Soiled
2C134
Telecom
2C135
Elec
2C136
Office/ Consult
2C118
Laundry
2C119
Resident
2C117
Bath
2C117A
Break
2C103
Staff Tlt
2C102
Equip
2C104
Passage
2C105HK
2C107
Clean
2C106 Bariatric
2C108
Bath
2C108A
Resident
2C116
Bath
2C116A Bath
2C115A
Resident
2C115 Resident
2C114
Bath
2C114A
Bath
2C109A
Resident
2C109 Resident
2C110
Bath
2C110A
WC/ Stretcher
2C111
WC/ Stretcher
2B155
Resident
2C112 Resident
2C113
Bath
2C113A Bath
2C112A
Formal Dining
Room
2A102 Chute
Vestibule
2A104
Vending
2A105
MATTRESS
STORAGE
2A101
Elec
2A100
Mech
2C133 Pantry
2C100A
Kitchen
2C100
Lounge
2B154
Dining Room
2C120 Nurse Work
2C123
Resident Kitchen
2C101
Resident
2B128
Bath
2B128A
Sitting Area
2B131Living Room
2B132
Meds
2B130 Nurse Work Area
2B129
Soiled
2B105
Elec
2B104 Tele
2B103 Private Dining
2B101
Office/ Consult
2B100
Kichen
2B152 Dining Room
2B150
Pantry
2B151 Resident Kitchen
2B149
Laundry
2B134 Nurse Office
2B133
Resident
2B135
Bath
2B135A
Break
2B148
Equip
2B145
Passage
2B146
Staff Toilet
2B147
Resident
2B136
Bath
2B136A
HK
2B143 Clean
2B144
Resident
2B137 Bath
2B137A
Resident
2B138
Bath
2B138A
Resident
2B139
Bath
2B139A Resident
2B140
Bath
2B140A
Resident
2B142
Bath
2B142A
Resident
2B141
Corridor
C2-19
Bath
2B141A
Room
2B153
Conference Room
2A126B
Conference Room
2A126A
Office
2A121
Toilet
2A122 Toilet
2A123
Office Suite
2A103
GEN STORAGE
2A126C
Tele
2A128
Corridor
C2-16A
Linen
2B146A
Linen
2C105A
Bridge
2E102
Corridor
C2-13
Elevator Lobby
C2-1
Corridor
C2-25
Corridor
C2-26 Corridor
C2-22
Corridor
C2-16
Corridor
C2-20
Elevator
P20
Elevator
P21
Elevator
S23
OFFICE
2A126
UP DN
Stair
Closet
2A101A
Closet
2A102A
Janitor
2A103B
Resident
2D125Bath
2D125A
Soiled
2D134
Elec
2D135 Tele
2D136
Private Dining
2D137Office/
Consult
2D138
Kitchen
2D100
Pantry
2D100A
Meds
2D123
Living Room
2D122
Office/
Consult
2D121 Laundry
2D120
Break
2D103
Equip
2D104
Passage
2D105
Staff Tlt
2D103A Bath
2D119A Resident
2D119
Resident
2D118Bath
2D118A
Resident
2D117 Bath
2D117A
HK
2D107
Clean
2D106
Bariatric
2D108 Bath
2D108A
Resident
2D116 Bath
2D116A Bath
2D109AResident
2D109
Resident
2D110
Bath
2D110A
Resident
2D115 Bath
2D115A
Resident
2D114 Bath
2D114A WC/ Stretcher
2D111
Storage
2C129
Nurse Work
2D124
Sitting Room
2D139
Dining Room
2D101 Resident
Kitchen
2D102
Linen
2D105A
Lounge
2D112
Corridor
C2-31
Corridor
C2-28
Elevator
P24
Vestibule
2D113
FEC-1
F F F F F F F F F F
F F
F F F F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F F S
F
F
F
F S
KHFS
KHFS
FAAP
F
HEAT DETECTOR (FIXED)
F
F
F
F
F
F
F
F
F
F
F
F
MATCHLINE FD144/FD145
MATCHLINE FD144/FD145
MATCHLINE FD144/FD145
MATCHLINE FD144/FD145
AATP
XN
XN
XNXN
XNXNXN
XN XN
XN
XN
XN
XNXN
XN
XD1
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S F
S
F S
F S
F S
F S
F S
F S F
S
F S
F S
F S
F S F
S
F S
F S
F S
F S
FS
FS
FS
FS
FS
FS
FS
FS
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
Drawing Title
Approved for Design Concept:
Project Title
Date
Location
Checked:
Building Number
A/E Project Number
Drawing Number
Drawn:
Revisions: Date
ENGINEERS/ARCHITECT:
W.G. (BILL) HEFNER VAMC
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
OFFICE OF
FACILITIES
MANAGEMENT
VA Project Number
FACILITY MANAGEMENT
DIVISION MANAGER
659-16-103
Architect
PROJECT LEAD
Fire Alarm, Electrical Engineer
VAMC SALISBURY
1601 Brenner Ave, Salisbury, NC 28144
100% CONSTRUCTION DOCUMENTS
SCBRSB11 DEC 2017
15-447REPLACE/UPGRADE CAMPUS
FIRE ALARM SYSTEM
(919) 858-7420 Consulting Group, PA www.acg-pa.com
Raleigh, NC Indianapolis, IN Philadelphia, PA Pittsburgh, PA Virginia Beach, VA Fort Collins, CO GURLITZ
ARCHITECTURAL
23894
SEAL
FD144
BLDG 42 SECOND FLOOR EAST
EXISTING/DEMOLITION 42
1 BLDG 42 SECOND FLOOR EAST
3/32"= 1'
HEALTH CARE OCCUPANCY - FULLY SPRINKLERED
DEMOLITION NOTES
1. FIRE ALARM DEVICES AND EQUIPMENT SHOWN
ON THIS SHEET IN HALF-TONE AND WITH NO TAG
ARE EXISTING-TO-REMAIN.
2. FIRE ALARM DEVICES AND EQUIPMENT SHOWN
ON THIS SHEET WITH THE TAG 'XD' ARE TO BE
DEMOLISHED.
3. FIRE ALARM DEVICES AND EQUIPMENT SHOWN
ON THIS SHEET WITH THE TAG 'XN' ARE TO BE
REPLACED.
4. FIRE ALARM DEVICES AND EQUIPMENT SHOWN
ON THIS SHEET WITH THE TAG 'XR' ARE TO BE
RELOCATED.
5. SEE CORRESPONDING 'FA' SHEET FOR NEW
DEVICE LOCATIONS.
6. WHERE NEW WALL DEVICES ARE NOT LOCATED
IN EXACTLY THE SAME LOCATION AS A
PREVIOUSLY-DEMOLISHED DEVICE, PROVIDE
STAINLESS STEEL BLANK COVER FOR BOX. CUT
OFF CONDUIT ABOVE CEILING AND REMOVE TO
NEAREST JUNCTION BOX.
7. WHERE NEW CEILING DEVICES ARE NOT
LOCATED IN EXACTLY THE SAME LOCATION AS A
PREVIOUSLY-DEMOLISHED DEVICE, REPLACE
CEILING TILE TO MATCH EXISTING TILES.
REMOVE CONDUIT AND WIRE TO THE NEAREST
JUNCTION BOX.
8. REPLACE ALL EXISTING DUCT DETECTORS AND
ASSOCIATED KEY SWITCHES. NEW KEY SWITCH
LOCATION SHALL BE ACCESSIBLE, WITH HEIGHT
ACCORDING TO NOTES AND SPECIFICATIONS.
DocuSign Envelope ID: 94B147EA-25A3-4143-9BDC-8EC43B57B4A8
6/25/2018
Closet
2A120 Office
2A119
Office
2A118
Office
2A117
Office
2A116
Stair
GM Breakroom
2A106
Supply Closet
2A111 Office
2A112
Office
2A113
Office
2A114
Office
2A115
Copy Room
2A110
Men's Locker/
Toilet
2A109
Women's Locker/
Toilet
2A107
Room
2A108
Vending
2A105
Resident
2B109
Resident
2B110
Bath
2B109A
Bath
2B110A
Elec
2B111 Mechanical
2B112Corridor
C2-42
Equip
2B113
Equip
2B114
Bath
2B115A
Corridor
C2-44Bath
2B122A Bath
2B121A
Bath
2B120A Bath
2B119A
Bath
2B118A
Bath
2B117A
Bath
2B116A
Lounge
2B123 Corridor
C2-43
Corridor
C2-17 Storage
2B107A Snoezelen Room
2B107
Corridor
C2-41
Mechanical
2B106
Bath
2B124A
Resident
2B124
Resident
2B125 Bath
2B125A
Resident
2B126
Bath
2B126A
Bath
2B127A
Resident
2B127
Resident
2B128
Bath
2B128A
Meds
2B130 Nurse Work Area
2B129
Soiled
2B105
Elec
2B104 Tele
2B103 Private Dining
2B101
Office/ Consult
2B100
Mechanical
2A124
Office
2A121
Toilet
2A122 Toilet
2A123
Elevator Lobby
C2-1
Stair
Stair
Resident
2B120
Resident
2B121
Resident
2B122 Resident
2B115
Resident
2B116
Resident
2B117
Resident
2B119
Resident
2B118
Corridor
C2-7
Corridor
C2-8
Corridor
C2-9
Waiting
C2-5
Secretary
C2-6
Corridor
C2-2
Secretary
C2-4 Lobby
C2-3
Elevator
P20
Elevator
P21
DN
Stair
Bariatric
2D132
Bath
2D132A
Bath
2D131A Resident
2D131
Resident
2D130 Bath
2D130A
Resident
2D129Bath
2D129A
Resident
2D128Bath
2D128A
Resident
2D127 Bath
2D127A
Bath
2D126A Resident
2D126
Resident
2D125Bath
2D125A
Mechanical
2D133
Soiled
2D134
Elec
2D135 Tele
2D136
Private Dining
2D137Office/
Consult
2D138
Meds
2D123
2D122
Nurse Work
2D124
Corridor
C2-32
FEC-1
F
F
F
F
F
F
F
F
F
F
F F
F
F
F
F
F
F
F
F S
F S
F S
F
F
NACP
NACP
FAAP
F
F
F
F
F
F
F
F
F
MATCHLINE FD144/FD145
MATCHLINE FD144/FD145
MATCHLINE FD144/FD145
MATCHLINE FD144/FD145
AATP
XN
XN
XN XN
XNXN
XN
XN
XN
XN XN
XN
XNXN
XD1
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
FS
FS
FS
F S
F S
F S
F S
FS
FS
FS
FS
FS
FS
FS
FS
FS
FS
F S
F S
FS
FS
F S
F S
F S
F S
F S
F S
F S
F S
F S
Drawing Title
Approved for Design Concept:
Project Title
Date
Location
Checked:
Building Number
A/E Project Number
Drawing Number
Drawn:
Revisions: Date
ENGINEERS/ARCHITECT:
W.G. (BILL) HEFNER VAMC
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
OFFICE OF
FACILITIES
MANAGEMENT
VA Project Number
FACILITY MANAGEMENT
DIVISION MANAGER
659-16-103
Architect
PROJECT LEAD
Fire Alarm, Electrical Engineer
VAMC SALISBURY
1601 Brenner Ave, Salisbury, NC 28144
100% CONSTRUCTION DOCUMENTS
SCBRSB11 DEC 2017
15-447REPLACE/UPGRADE CAMPUS
FIRE ALARM SYSTEM
(919) 858-7420 Consulting Group, PA www.acg-pa.com
Raleigh, NC Indianapolis, IN Philadelphia, PA Pittsburgh, PA Virginia Beach, VA Fort Collins, CO GURLITZ
ARCHITECTURAL
23894
SEAL
FD145
BLDG 42 SECOND FLOOR WEST
EXISTING/DEMOLITION 42
1 BLDG 42 SECOND FLOOR WEST
3/32"= 1'
HEALTH CARE OCCUPANCY - FULLY SPRINKLERED
DEMOLITION NOTES
1. FIRE ALARM DEVICES AND EQUIPMENT SHOWN
ON THIS SHEET IN HALF-TONE AND WITH NO TAG
ARE EXISTING-TO-REMAIN.
2. FIRE ALARM DEVICES AND EQUIPMENT SHOWN
ON THIS SHEET WITH THE TAG 'XD' ARE TO BE
DEMOLISHED.
3. FIRE ALARM DEVICES AND EQUIPMENT SHOWN
ON THIS SHEET WITH THE TAG 'XN' ARE TO BE
REPLACED.
4. FIRE ALARM DEVICES AND EQUIPMENT SHOWN
ON THIS SHEET WITH THE TAG 'XR' ARE TO BE
RELOCATED.
5. SEE CORRESPONDING 'FA' SHEET FOR NEW
DEVICE LOCATIONS.
6. WHERE NEW WALL DEVICES ARE NOT LOCATED
IN EXACTLY THE SAME LOCATION AS A
PREVIOUSLY-DEMOLISHED DEVICE, PROVIDE
STAINLESS STEEL BLANK COVER FOR BOX. CUT
OFF CONDUIT ABOVE CEILING AND REMOVE TO
NEAREST JUNCTION BOX.
7. WHERE NEW CEILING DEVICES ARE NOT
LOCATED IN EXACTLY THE SAME LOCATION AS A
PREVIOUSLY-DEMOLISHED DEVICE, REPLACE
CEILING TILE TO MATCH EXISTING TILES.
REMOVE CONDUIT AND WIRE TO THE NEAREST
JUNCTION BOX.
8. REPLACE ALL EXISTING DUCT DETECTORS AND
ASSOCIATED KEY SWITCHES. NEW KEY SWITCH
LOCATION SHALL BE ACCESSIBLE, WITH HEIGHT
ACCORDING TO NOTES AND SPECIFICATIONS.
#KEYED NOTES
1. REPLACE AATP (NOTIFIER XPIQ) WITH A NACP
AND DAA. RECONFIGURE NAC AND SPEAKER
CIRCUITS AS REQUIRED.
PLAY ROOM
MEDITATION
GAME ROOM
FAMILY ROOM
EQUIPEMENT
BREAK RM
PHY OFF
NP OFF
COORD OFF
NUR MGR OFF
SW OFF
FLEX OFF
WELCOME CTR.
DINING ROOM
VESTIBULE
LOBBY
KITCHEN
FAMILY KITCHEN
SOILED UTILITY
HK
FAM SUITE
116A
FAM BATH
NURSE
CORR
CLEAN SUP
TELECOM
MEDS
MECHANICAL
EM ELECT
NORM ELEC
CHAPLAIN
EQUIP. STORAGE
CORR
12B
BATH
QUIET RM
PASSAGE
66 146
LAUNDRY
NURSE
PASSAGE
BATHTIQUE
TLT
TLT
TLT
PASSAGE
TLT
TLT
OFFICE
RESIDENT ROOM
RESIDENT ROOM
RESIDENT ROOM
RESIDENT ROOM
RESIDENT ROOM
RESIDENT ROOM
11B
BATH
10B
BATH
9B
BATH
8B
BATH
7B
BATH
ELECTRICAL CLT
LIVING ROOM
783 104
CORR
NURSE
CORR
CORR
RESIDENT ROOM
6B
BATH
RESIDENT ROOM
RESIDENT ROOM
RESIDENT ROOM
RESIDENT ROOM
RESIDENT ROOM
5B
BATH
4B
BATH
3B
BATH
2B
BATH
1B
BATH
PASS
CORR
MECHANICAL
KENNEL
SECURITY CLOSET
115A
LINENS
Corr
124 BUILDING 42
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F F
F
FF
F
F
F
F
FA
C
P
FA
A
P
FAAP
FAAP
Fco
Fco
Fco
N A
C P
KHFS
FS
FS
FS
FS
FS
FS
FS
FS
FS
FS
FS
FS
FS
FS
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
F S
FS
F S
F S
F S
F S
FS
FS
1. EXISTING FIRE ALARM SYSTEM SHALL NOT BE
DEMOLISHED.
Drawing Title
Approved for Design Concept:
Project Title
Date
Location
Checked:
Building Number
A/E Project Number
Drawing Number
Drawn:
Revisions: Date
ENGINEERS/ARCHITECT:
W.G. (BILL) HEFNER VAMC
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
OFFICE OF
FACILITIES
MANAGEMENT
VA Project Number
FACILITY MANAGEMENT
DIVISION MANAGER
659-16-103
Architect
PROJECT LEAD
Fire Alarm, Electrical Engineer
VAMC SALISBURY
1601 Brenner Ave, Salisbury, NC 28144
100% CONSTRUCTION DOCUMENTS
SCBRSB11 DEC 2017
15-447REPLACE/UPGRADE CAMPUS
FIRE ALARM SYSTEM
(919) 858-7420 Consulting Group, PA www.acg-pa.com
Raleigh, NC Indianapolis, IN Philadelphia, PA Pittsburgh, PA Virginia Beach, VA Fort Collins, CO GURLITZ
ARCHITECTURAL
23894
SEAL
FD146
BLDG 43 EXISTING/DEMO
1 BLDG 43 (ALL EXISTING DEVICES TO REMAIN)
3/32"= 1'
HEALTH CARE OCCUPANCY - FULLY SPRINKLERED
GENERAL NOTES
FACP-04
FACP-21
FANCC
FACP-08
FB-11
FACP-11
FB-04A
FB-02
FACP-02
FB-01A
FB-14E
FACP-14E
FACP-01
FB-01
FB-03
FACP-03
FB-07A
FB-07
FACP-07
FACP-05
FB-15
FACP-15
FB-10
FANA-18
FACP-06
FB-42
FACP-42
FB-13
FACP-13
ONE FIBER PAIR
(TYP ALL LINES)
FIBER PAIRS UNDER
THE SAME JACKET
(TYP ALL ELIPSES)
DEMO
DEMO
DEMO
DEMO
DEMO
DEMO
FOER-02
FOER-05A
FOER-05B
FOER-15 FB-18FB-08FB-21
FB-06
DEMODEMODEMODEMO
DEMO
DEMO
FACP-43
DEMO
DEMO
DEMO
FB-04
FACP-18
DEMO
FIBER PAIR CONNECTOR
(TYP)
FIBER SPLICE
(TYP)
FB-05
EXISTING FIBER INTERCONNECTION NOTES:
1. INTERCONNECTIONS SHOWN BASED ON EXISTING DRAWINGS
AND ON BEST AVAILABLE INFORMATION AT TIME OF
SURVEY/VISUAL INSPECTION. CONTRACTOR SHALL VERIFY
AS REQUIRED TO COMPLETE WORK.
2. MOST FIRE ALARM FIBER SHARES A JACKET WITH OIT,
SECURITY, AND/OR ENERGY MANAGEMENT. THIS FIBER
SHALL NOT BE DEMOLISHED AND SHALL REMAIN IN-SERVICE
FOR THE DURATION OF WORK. FIRE ALARM FIBER STRANDS
WHICH SHARE A JACKET WITH THESE OTHER SYSTEMS
SHALL BE DISCONNECTED AND SHALL BE LABELED AS
'SPARE'.
3. WHERE FIRE ALARM FIBER DOES NOT SHARE A JACKET WITH
OTHER SYSTEMS, THE FIBER CABLE SHALL BE DEMOLISHED.
WHERE THE RACEWAY IS NOT SHARED WITH OTHER
SYSTEMS, RACEWAY SHALL BE DEMOLISHED.
4. WHERE NOTED 'DEMO' FIBER HAS BEEN DETERMINED TO BE
UNDER A JACKET DEDICATED TO FIRE ALARM. CONTRACTOR
SHALL VERIFY PRIOR TO DEMOLITION. WHERE NOT LABELED
AS 'DEMO', FIRE ALARM FIBER SHARES JACKET WITH OTHER
SYSTEMS AND SHALL REMAIN. CONTRACTOR SHALL VERIFY
AND DEMO ALL DEDICATED FIRE ALARM FIBER.
5. DO NOT BEGIN FIBER DEMOLITION UNTIL AFTER NEW FIRE
ALARM SYSTEMS IN EVERY BUILDING ARE FULLY INSTALLED
AND OPERATIONAL. SEE PHASING IN SPECIFICATIONS FOR
ADDITIONAL DETAILS.
6. BUILDINGS 9 AND 20 ARE NOT SHOWN IN DIAGRAM. AT TIME
OF DESIGN, BUILDINGS WERE UNDER CONSTRUCTION.
PRECISE FIRE ALARM INTERCONNECTION IS NOT KNOWN.
Drawing Title
Approved for Design Concept:
Project Title
Date
Location
Checked:
Building Number
A/E Project Number
Drawing Number
Drawn:
Revisions: Date
ENGINEERS/ARCHITECT:
W.G. (BILL) HEFNER VAMC
B
A
C
D
E
F
1 2 3 4 5 6 7 9
F
E
D
C
B
A
97 8654321
OFFICE OF
FACILITIES
MANAGEMENT
VA Project Number
FACILITY MANAGEMENT
DIVISION MANAGER
659-16-103
Architect
PROJECT LEAD
Fire Alarm, Electrical Engineer
VAMC SALISBURY
1601 Brenner Ave, Salisbury, NC 28144
100% CONSTRUCTION DOCUMENTS
SCBRSB11 DEC 2017
15-447REPLACE/UPGRADE CAMPUS
FIRE ALARM SYSTEM
(919) 858-7420 Consulting Group, PA www.acg-pa.com
Raleigh, NC Indianapolis, IN Philadelphia, PA Pittsburgh, PA Virginia Beach, VA Fort Collins, CO GURLITZ
ARCHITECTURAL
23894
SEAL
FD601
EXISTING/DEMO FIBER INTERCONNECTION
DIAGRAM, FIRE RISER ALARM DIAGRAM
1 EXISTING/DEMO FIBER INTERCONNECTION DIAGRAM
NTS
| 15-447-FD144 B42F2 East, West-FD144 |
| Sheets and Views |
| FD144 |
| 15-447-FD144 B42F2 East, West-FD145 |
| Sheets and Views |
| FD145 |
| 15-447-FD146 B43-FD146 |
| Sheets and Views |
| FD146 |
| 15-447-FD601 FIBER INTERCONNECTION EXISTING-FD601 |
| Sheets and Views |
| FD601 |
| 2018-06-26T04:52:41-0700 | |
| DocuSign, Inc. | |
| Digitally verifiable PDF exported from www.docusign.com |