36C24418B0585-0001004.pdf
PDF 807 KB Posted
- Solicitation number
- 36C24418B0585
About this file
36C24418B0585 0001 Drawing 01-E701.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24419C0030-000.docx | DOCX document | |
| 36C24418B0585-0004001.pdf | ||
| 36C24418B0585-0004000.docx | DOCX document | |
| 36C24418B0585-0003001.pdf | ||
| 36C24418B0585-0003000.docx | DOCX document | |
| 36C24418B0585-0002002.pdf | ||
| 36C24418B0585-0002001.pdf | ||
| 36C24418B0585-0002000.docx | DOCX document | |
| 36C24418B0585-0001001.pdf | ||
| 36C24418B0585-0001005.pdf | ||
| 36C24418B0585-0001003.pdf | ||
| 36C24418B0585-0001006.pdf | ||
| 36C24418B0585-0001002.pdf | ||
| 36C24418B0585-0001000.docx | DOCX document | |
| 36C24418B0585-003.docx | DOCX document | |
| 36C24418B0585-001.docx | DOCX document | |
| 36C24418B0585-006.docx | DOCX document | |
| 36C24418B0585-002.docx | DOCX document | |
| 36C24418B0585-005.pdf | ||
| 36C24418B0585-004.pdf | ||
| 36C24418B0585-000.docx | DOCX document |
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
3 1A
A
SECTION A-A
FLOOR OR WALL ASSEMBLY -- MIN 4-1/2 IN. THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS *. MAX DIAM OF OPENING IS 12 IN. SEE CONCRETE BLOCKS (CAZT) CATEGORY IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF
MANUFACTURERS.
THROUGH PENETRANTS -- ONE METALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED WITHIN THE FIRESTOP SYSTEM. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY.
THE ANNULAR SPACE SHALL BE 0 IN. (POINT CONTACT) TO MAX 1-1/4 IN. THE FOLLOWING TYPES AND SIZES OF
METALLIC PIPES, CONDUITS OR TUBING MAY BE USED:
A. STEEL PIPE -- NOM 10 IN. DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE.
B. IRON PIPE -- NOM 10 IN. DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.
C. CONDUIT -- NOM 4 IN. DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR STEEL CONDUIT.
D. COPPER TUBING -- NOM 4 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING.
E. COPPER PIPE -- NOM 4 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE.
PACKING MATERIAL -- MIN 3 IN. THICKNESS OF MIN 4 PCF MINERAL WOOL BATT INSULATION FOR NOM 4 IN. DIAM (AND SMALLER) PIPES, CONDUITS OR TUBINGS AND A MIN 4 IN. THICKNESS OF MIN 4 PCF MINERAL WOOL BATT INSULATION FOR PIPE GREATER THAN NOM 4 IN. DIAM, FIRMLY PACKED INTO OPENING AS A PERMANENT FORM.
PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF WALL AS
REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL.
FILL, VOID OR CAVITY MATERIAL* -- SEALANT -- MIN 1/2 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH THE TOP SURFACE OF FLOOR OR BOTH SURFACES OF WALL. AT THE POINT OF CONTACT LOCATION BETWEEN PIPE AND CONCRETE, A MIN 1/2 IN. DIAM BEAD OF FILL MATERIAL SHALL BE APPLIED AT THE CONCRETE/PIPE INTERFACE ON THE TOP SURFACE OF FLOOR AND ON BOTH SURFACES OF WALL. W RATING
APPLIES ONLY WHEN CP601S OR CP604 SEALANT IS USED.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- CP601S, CP604, CP606 OR FS-ONE SEALANT
*BEARING THE UL CLASSIFICATION MARK
2 1B
1A
D
D
SECTION D-D
WALL ASSEMBLY -- THE 1 OR 2 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:
A. STUDS -- WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. STEEL STUDS TO BE MIN 2-1/2 IN. WIDE AND SPACED MAX 24 IN. OC. WHEN STEEL STUDS ARE USED AND THE DIAM OF OPENING EXCEEDS THE WIDTH OF STUD CAVITY, THE OPENING SHALL BE FRAMED ON ALL SIDES USING LENGTHS OF STEEL STUD INSTALLED BETWEEN
THE VERTICAL STUDS AND SCREW-ATTACHED TO THE STEEL STUDS AT EACH END. THE FRAMED OPENING IN THE WALL SHALL BE 4 TO 6 IN. WIDER AND 4 TO 6 IN. HIGHER THAN THE DIAM OF THE PENETRATING ITEM SUCH THAT, WHEN THE PENETRATING ITEM IS INSTALLED IN THE OPENING, A 2 TO 3 IN. CLEARANCE IS PRESENT BETWEEN THE
PENETRATING ITEM AND THE FRAMING ON ALL FOUR SIDES.
B. GYPSUM BOARD* -- 5/8 IN. THICK, 4 FT WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM BOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE
INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF OPENING IS 32-1/4 IN.
FOR STEEL STUD WALLS. MAX DIAM OF OPENING IS 14-1/2 IN. FOR WOOD STUD WALLS.
THE F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE FIRE RATING OF THE WALL ASSEMBLY.
THROUGH-PENETRANTS -- ONE METALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE SHALL BE MIN 0 IN. TO MAX 2-1/4 IN. PIPE MAY BE INSTALLED WITH CONTINUOUS POINT CONTACT. PIPE, CONDUIT OR TUBING MAY BE INSTALLED AT AN ANGLE NOT GREATER THAN 45 DEGREES FROM PERPENDICULAR. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED:
A. STEEL PIPE -- NOM 30 IN DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE.
B. IRON PIPE -- NOM 30 IN. DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.
C. CONDUIT -- NOM 4 IN DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR 6 IN. DIAM STEEL CONDUIT.
D. COPPER TUBING -- NOM 6 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING.
E. COPPER PIPE -- NOM 6 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE.
FILL, VOID OR CAVITY MATERIAL* -- SEALANT -- MIN 5/8 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. AT THE POINT OR CONTINUOUS CONTACT LOCATIONS BETWEEN PIPE AND WALL, A MIN 1/2 IN. DIAM BEAD OF FILL MATERIAL SHALL BE APPLIED AT THE PIPE WALL INTERFACE ON BOTH
SURFACES OF WALL .
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- FS-ONE SEALANT
*BEARING THE UL CLASSIFICATION MARK
LENGTH AS REQUIRED
CONDUIT CLAMP.
SIZE AS REQUIRED
INTEGRAL
GALVANIZED
LIPPED STEEL
MOUNTING
CHANNEL
REFER TO PLANS FOR
QUANTITY & SIZE OF
CONDUITS
NOTES
1. METAL CHANNEL STRUT SUPPORT LONGER THAN
36" SHALL BE INSTALLED WITH A CENTER SUPPORT
ROD.
2. FASTEN THREADED ROD TO STRUCTURE BY APPROVED
METHOD PER SPECIFICATION 26 0533, RACEWAYS AND
BOXES FOR ELECTRICAL SYSTEMS. FIELD VERIFY
EXACT CONDITIONS.
3. FOR TRAPEZE INSTALLATIONS IN SEISMIC AREAS REFER
TO SPECIFICATION SECTION 10 05 41, SEISMIC
RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL
COMPONENTS.
LOCKING SQUARE
WASHER & LOCKNUT
3/8" MIN GALVANIZED
THREADED ROD, TYP.
WASHER &
LOCKNUT
INTEGRAL
GALVANIZED
LIPPED STEEL
MOUNTING
CHANNEL
WALL SLEEVE
SEAL ALL PENETRATIONS
NOTES:
1. LABEL SHALL BE DISPLAYED ON ALL SWITCHBOARDS, PANELBOARDS,
TRANSFER SWITCHES AND PULLBOXES (MULTIPLE VOLTAGES).
2. NAMEPLATE SHALL BE WHITE LETTERING ON BLACK MICARTA.
3. IF ONLY ONE VOLTAGE IS PRESENT, LABEL SHALL INDICATE ONLY THAT
RESPECTIVE VOLTAGE.
2" H
IG
H
4" WIDE
VOLTAGE
208Y / 120V
PHASE A BLACK
PHASE B RED
PHASE C BLUE
NEUTRAL WHITE
VOLTAGE
480Y / 277V
PHASE A BROWN
PHASE B ORANGE
PHASE C YELLOW
NEUTRAL GRAY
GROUND
PHASE
CONDUCTOR
CONDUITBREAKER SIZE
NOTE:
1. PROVIDE A CONDUCTOR PER BREAKER POLE. THESE ARE THE MINIMUM SIZES REQUIRED
FOR EACH CIRCUIT. CONTRACTOR TO MAKE ALL THE NECESSARY FIELD ADJUSTMENTS TO
COMPENSATE FOR VOLTAGE DROP.
2. IN GENERAL, VOLTAGE DROP FOR ANY BRANCH CIRCUIT SHALL NOT EXCEED 3%. VOLTAGE
DROP FOR ANY FEEDER SHALL NOT EXCEED 2%. WHERE VOLTAGE DROP EXCEEDS THESE
REQUIREMENTS, THE CONTRACTOR SHALL INCREASE THE SIZE OF THE CONDUCTORS AND
RACEWAY AS REQUIRED.
BRANCH CIRCUIT WIRING SCHEDULE
NEUTRAL
CONDUCTOR
3/4"
3/4"
3/4"
1"
1"
1"
1"
1-1/4"
1-1/4"
1-1/2"
15A
20A
30A
35A
40A
45A
50A
60A
70A
80A
STAINLESS
CLAMP (TYP.)
PREFABRICATED RUBBER BOOT
CAP WITH GRADUATED STEPS
AND WEATHER-PROOF
PRESSURE SEAL TO COLLAR
SEALANT AT PENETRATION
TO MEMBRANE JUNCTURE
BY ROOFING CONTRACTOR
ROOF MEMBRANE
ROOF
WATER CUT-OFF
MASTIC COMPATIBLE
WITH ROOF MEMBRANE
CONDUIT CLAMP
SIZE AS REQUIRED INTEGRAL GALVANIZED
LIPPED STEEL
MOUNTING CHANNEL
CONDUIT CLAMP
SIZE AS REQUIRED
LOCKING SQUARE WASHER
AND LOCKNUT
3/8" MIN. GALVANIZED
THREADED ROD, (TYP.)
STEEL EXPANSION ANCHOR
MULTIPLE MEMBRANE STRIPPING PLIES
FEATHERED AT FIELD OF ROOF BY
ROOFING CONTRACTOR. PRIME FLANGE
BEFORE STRIPPING.
PRE-FABRICATED FORMED .06" THICK
ALUMINUM FLASHING ROUND COLLAR
WITH MIN. 3" WIDE FLANGE
ATTACH TO ROOF PER MANUFACTURER'S
INSTRUCTIONS
BATT INSULATION
CONDUIT
(TYP.)
SEAL-OFF
FITTING
(TYP.)
1. MAINTAIN A MINIMUM CLEARANCE OF 12" ON ALL SIDES OF ROOF PENETRATION
FROM WALLS, CURBS, AND OTHER PROJECTIONS TO FACILITATE PROPER FLASHING.
2. FLANGES OF ADJACENT FLASHINGS SHALL NOT BE CUT OR OVERLAPPED.
3. VERIFY ROOF AND STRUCTURAL SYSTEM WITH ARCHITECT.
4. COORDINATE FLASHING INSTALLATION WITH ROOFING CONTRACTOR TO ENSURE
PROPER METHODS AND MATERIALS ARE USED TO MAINTAIN ROOF WARRANTY.
GENERAL NOTES:
ARC FLASH AND SHOCK HAZARD
APPROPRIATE PPE REQUIRED
480Y/277V-3∅-4W-60HZ
2500 AMPERES HORIZONTAL BUS
SHORT-CIRCUIT CURRENT RATING
65,000 AMPERES RMS SYM
TYPICAL PANELBOARD
OR SWITCHBOARD
NOTES:
1. THE PROSPECTIVE SYMMETRICAL FAULT CURRENT AT A NOMINAL VOLTAGE TO WHICH AN
APPARATUS OR SYSTEM IS ABLE TO BE CONNECTED WITHOUT SUSTAINING DAMAGE EXCEEDING
ACCEPTANCE CRITERIA, SHALL BE DISPLAYED ON THE EXTERIOR OF THE STRUCTURE, OR ON THE
INSIDE COVER OF A PANELBOARD.
CONSULTANTS:
Drawing Title
Approved: Project Director
Project Title:
Location:
Date: Checked: Drawn:
Drawing Number
Building Number
Project Number
Office of Construction and Facilities Management
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
FULLY SPRINKLERED
A
B
C
D
E
F
6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t
209 SANDUSKY STREET
PITTSBURGH, PA 15212
PH: 412.287.7333
www.ae-works.com
AE WORKS PROJECT NUMBER:
ARCHITECTS/ENGINEERS:SEAL
Revision# Date
6/ 8/
:1
9:
A M
CORRECT
RETRO-COMMISSIONING
DISCREPANCIES
503-15-205
BK BK
JAMES E. VAN ZANDT MEDICAL CENTER
ALTOONA, PA 16602
01-E701
ELECTRICAL SCHEDULES AND DETAILS
06/07/2018
14-
100% CONSTRUCTION DOCUMENTS
EQUIPMENT CONNECTION SCHEDULE
TAG IDENTIFICATION HP
FLA /
MCA
VOLTAGE / PH /
LOAD
CKT. BKR /
MCP PANEL CKT. #
NEMA
TYPE
DISC / POLES /
FUSE FEEDER SIZE
CONDUIT
SIZE COMMENTS
AHU-1 (RF-1) AHU-1 RETURN FAN 2 3.4 FLA 480 V/3-2823 VA 15A ME-MCC1 2 1 VFD W/ 30A/3P (3) #12, (1) #12 GND 3/4" RE-USE EXISTING MCP
AHU-1 (SF-1) AHU-1 SUPPLY FAN 15 21 FLA 480 V/3-17438 VA 50A ME-MCC1 1 1 VFD W/ 60A/3P (3) #6, (1) #10 GND 1" RE-USE EXISTING MCP
AHU-3 (RF-3) AHU-3 RETURN FAN 10 32.2 FLA 208 V/3-11587 VA 60A ESP-3H 44,46,48 1 VFD W/ 60A/3P (3) #4, (1) #10 GND 1-1/4" PROVIDE NEW CIRCUIT BREAKER
AHU-3 (SF-3) AHU-3 SUPPLY FAN 30 92 FLA 208 V/3-33105 VA 125A ESP-3H 49,51,53 1 VFD W/ 200A/3P (3) #1, (1) #6 GND 2" PROVIDE NEW CIRCUIT BREAKER
AHU-5 (RF-5) AHU-5 RETURN FAN 5 7.6 FLA 480 V/3-6311 VA 15A ME-MCC2 9 1 VFD W/ 30A/3P (3) #12, (1) #12 GND 3/4" RE-USE EXISTING MCP
AHU-5 (SF-5) AHU-5 SUPPLY FAN 10 14 FLA 480 V/3-11626 VA 25A ME-MCC2 7 1 VFD W/ 30A/3P (3) #10, (1) #10 GND 3/4" PROVIDE NEW MCP
AHU-6 (RF-6) AHU-6 RETURN FAN 3 11 FLA 208 V/3-3958 VA 20A PP-4 1,3,5 1 VFD W/ 30A/3P (3) #12, (1) #12 GND 3/4" RE-USE EXISTING CIRCUIT BREAKER
AHU-6 (SF-6) AHU-6 SUPPLY FAN 15 48.3 FLA 208 V/3-17380 VA 100A PP-4 16,18,20 1 VFD W/ 100A/3P (3) #1, (1) #8 GND 2" RE-USE EXISTING CIRCUIT BREAKER
RTU-L ROOF TOP UNIT - LAUNDRY - 51.9 MCA 208 V/3-17056 VA 60A PPAC 13,15,17 3R VFD W/ 60A/3P (3) #4, (1) #10 GND 1-1/4" PROVIDE NEW CIRCUIT BREAKER
NOT TO SCALE
CONDUIT THROUGH CONCRETE WALL - FLOOR ASSEMBLY
NOT TO SCALE
CONDUIT THROUGH FIRE RATED DRYWALL PARTITION
NOT TO SCALE
CONDUIT TRAPEZE MOUNTING DETAIL
NOT TO SCALE
DETAIL - WALL SLEEVE
NOT TO SCALE
BRANCH WIRING IDENTIFICATION
NOT TO SCALE
CONDUIT ROOF PENETRATION DETAIL
NOT TO SCALE
EQUIPMENT LABELING REQUIREMENTS
EQUIPMENT SCHEDULE NOTES:
1. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION OF EQUIPMENT.
2. E.C. SHALL VERIFY AND COORDINATE EXACT OCPD AND OVERLOAD RATING WITH RESPECTIVE CONTRACTOR AND EQUIPMENT SUPPLIER. ADJUST CIRCUIT ACCORDINGLY.
3. PROVIDE CIRCUITING AND CONNECTIONS FROM ALL VFDS, FUSED AND NON-FUSED DISCONNECT SWITCHES, COMBINATION STARTERS, MANUAL MOTOR STARTERS, AND
CONTROLLERS TO MECHANICAL EQUIPMENT SERVED. CONDUCTOR AND CONDUIT SIZES SHALL MATCH THOSE SERVING THE EQUIPMENT FROM THE PANELBOARD.
427.8 :TOTAL DEMAND LOAD (A)
154.1 :TOTAL DEMAND LOAD (KVA)
100.00% :TOTAL DEMAND FACTOR
427.8 :TOTAL CONNECTED LOAD (A)
1. RE-USE EXISTING CIRCUIT BREAKER. 154.1 :TOTAL CONNECTED LOAD (KVA)
NOTES: 428.1 428.1 428.1 :CONNECTED LOAD/PHASE (A)
51.4 51.4 51.4 :CONNECTED LOAD/PHASE (KVA)
41 42
39 40
37 0.50 -- -- -- 38
35 -- -- -- 2.10 0.50 -- -- -- 36
33 -- -- -- 2.10 0.50 15 A 3 EXISTING - 1 QUAD + 1 DUPLEX RM. 11 34
31 EXISTING - COND. PUMP RM 11 3 30 A 2.10 0.00 -- -- -- 32
29 -- -- -- 15.00 0.00 -- -- -- 30
27 -- -- -- 15.00 0.00 15 A 3 SPARE 28
25 EXISTING - PANEL K 3 200 A 15.00 0.00 -- -- -- 26
23 -- -- -- 0.00 0.00 -- -- -- 24
21 -- -- -- 0.00 0.00 150 A 3 EXISTING - KITC. BOOSTER HEATER-NOT... 22
19 SPARE 3 225 A 0.00 5.79 -- -- -- 20
17 -- -- -- 0.00 5.79 -- -- -- 18
15 -- -- -- 0.00 5.79 100 A 3 AHU-6 (SF-6) (See Note 1) 16
13 SPARE 3 50 A 0.00 0.00 -- -- -- 14
11 -- -- -- 0.00 0.00 50 A 2 SPARE 12
9 -- -- -- 0.00 0.00 -- -- -- 10
7 SPARE 3 50 A 0.00 0.00 50 A 2 SPARE 8
5 -- -- -- 1.32 26.66 -- -- -- 6
3 -- -- -- 1.32 26.66 -- -- -- 4
1 AHU-6 (RF-6) (See Note 1) 3 20 A 1.32 26.66 350 A 3 EXISTING - UPS NEW COMP RM 2
NO DESCRIPTION P TRIP A B C TRIP P DESCRIPTION NO
CKT CIRCUIT BREAKER LOAD (KVA) BREAKER CIRCUIT CKT
A.I.C. RATING EXISTING MOUNTING: SURFACE
BUS RATING: 600 A MCB RATING: 600 A FED FROM:
RATINGS: 208/120V, 3PH, 4W MAINS TYPE: MCB LOCATION:
EXISTING PANEL PP-4
158.9 :TOTAL DEMAND LOAD (A)
57.3 :TOTAL DEMAND LOAD (KVA)
100.00% :TOTAL DEMAND FACTOR
158.9 :TOTAL CONNECTED LOAD (A)
1. PROVIDE NEW CIRCUIT BREAKER. 57.3 :TOTAL CONNECTED LOAD (KVA)
NOTES: 159.0 159.0 159.0 :CONNECTED LOAD/PHASE (A)
19.1 19.1 19.1 :CONNECTED LOAD/PHASE (KVA)
41 42
39 40
37 38
35 36
33 34
31 32
29 -- -- -- 1.90 30
27 -- -- -- 1.90 28
25 EXISTING - HEAT PUMP 3 20 A 1.90 26
23 -- -- -- 0.00 1.90 -- -- -- 24
21 -- -- -- 0.00 1.90 -- -- -- 22
19 SPARE 3 30 A 0.00 1.90 20 A 3 EXISTING - HEAT TRACE 20
17 -- -- -- 5.69 2.90 -- -- -- 18
15 -- -- -- 5.69 2.90 -- -- -- 16
13 RTU-L (See Note 1) 3 60 A 5.69 2.90 30 A 3 EXISTING KITCHEN PUMP 14
11 -- -- -- 4.80 0.00 -- -- -- 12
9 -- -- -- 4.80 0.00 -- -- -- 10
7 EXISTING - KITCHEN FAN 3 50 A 4.80 0.00 50 A 3 SPARE 8
5 -- -- -- 1.90 0.00 -- -- -- 6
3 -- -- -- 1.90 0.00 -- -- -- 4
1 EXISTING - HEAT PUMP 3 20 A 1.90 0.00 200 A 3 SPARE 2
NO DESCRIPTION P TRIP A B C TRIP P DESCRIPTION NO
CKT CIRCUIT BREAKER LOAD (KVA) BREAKER CIRCUIT CKT
A.I.C. RATING EXISTING MOUNTING: SURFACE
BUS RATING: 400 A MCB RATING: 400 A FED FROM:
RATINGS: 208/120V, 3PH, 4W MAINS TYPE: MCB LOCATION:
EXISTING PANEL PPAC
34.1 :TOTAL DEMAND LOAD (A)
28.4 :TOTAL DEMAND LOAD (KVA)
100.00% :TOTAL DEMAND FACTOR
TRIP SIZE AS INDICATED AND RECOMMENDED BY EQPM. MANUFACTURER. 34.1 :TOTAL CONNECTED LOAD (A)
1. PROVIDE NEW OR MODIFY EXISTING BUCKET WITH NEW FUSE/BREAKER 28.4 :TOTAL CONNECTED LOAD (KVA)
NOTES: 34.1 34.1 34.1 :CONNECTED LOAD/PHASE (A)
9.5 9.5 9.5 :CONNECTED LOAD/PHASE (KVA)
9 Space -- -- 0.0 --
8 SPARE 3 15 A 0.0 0.0 0.0
7 EXISTING - 1-SF7 3 3 A 0.3 0.3 0.3
6 EXISTING - 1-EF17 3 7 A 0.8 0.8 0.8
5 EXISTING - 1-EF8 3 3 A 0.3 0.3 0.3
4 EXISTING - 1-EF6 3 7 A 0.8 0.8 0.8
3 EXISTING - 1-EF5 3 3 A 0.4 0.4 0.4
2 AHU-1 (RF-1) 3 15 A 0.9 0.9 0.9 SEE NOTE 1
1 AHU-1 (SF-1) 3 50 A 5.8 5.8 5.8 SEE NOTE 1
CKT CIRCUIT DESCRIPTION POLES TRIP A B C REMARKS
BREAKER LOAD (KVA)
A.I.C. RATING EXISTING MOUNTING: Surface
BUS RATING: 600 A FED FROM:
RATINGS: 480/277V, 3PH, 4W MAINS TYPE: MLO LOCATION:
EXISTING SWITCHBOARD ME-MCC1
156.9 :TOTAL DEMAND LOAD (A)
130.4 :TOTAL DEMAND LOAD (KVA)
100.00% :TOTAL DEMAND FACTOR
TRIP SIZE AS INDICATED AND RECOMMENDED BY EQPM. MANUFACTURER. 156.9 :TOTAL CONNECTED LOAD (A)
1. PROVIDE NEW OR MODIFY EXISTING BUCKET WITH NEW FUSE/BREAKER 130.4 :TOTAL CONNECTED LOAD (KVA)
NOTES: 157.0 157.0 157.0 :CONNECTED LOAD/PHASE (A)
43.5 43.5 43.5 :CONNECTED LOAD/PHASE (KVA)
16 Space -- -- 0.0 --
15 SPARE 3 15 A 0.0 0.0 0.0
14 SPARE 3 15 A 0.0 0.0 0.0
13 EXISTING - 1-P6 3 15 A 2.1 2.1 2.1
12 EXISTING - 1-P5 3 15 A 3.1 3.1 3.1
11 Space -- -- 0.0 --
10 EXISTING - 1-EF13 3 3 A 0.3 0.3 0.3
9 AHU-5 (RF-5) 3 15 A 2.1 2.1 2.1 SEE NOTE 1
8 EXISTING - 1-RF2 3 15 A 2.1 2.1 2.1
7 AHU-5 (SF-5) 3 25 A 3.9 3.9 3.9 SEE NOTE 1
6 EXISTING - 1-SF4 3 50 A 7.5 7.5 7.5
5 EXISTING - 1-SF2 3 100 A 14.4 14.4 14.4
4 EXISTING - 1-EF11 3 3 A 0.6 0.6 0.6
3 EXISTING - 1-EF9 3 3 A 0.3 0.3 0.3
2 EXISTING - 1-EF3 3 7 A 1.3 1.3 1.3
1 EXISTING - 1-EF1 3 30 A 5.8 5.8 5.8
CKT CIRCUIT DESCRIPTION POLES TRIP A B C REMARKS
BREAKER LOAD (KVA)
A.I.C. RATING EXISTING MOUNTING: Surface
BUS RATING: 600 A FED FROM:
RATINGS: 480/277V, 3PH, 4W MAINS TYPE: MLO LOCATION:
EXISTING SWITCHBOARD ME-MCC2
215.7 :TOTAL DEMAND LOAD (A)
77.7 :TOTAL DEMAND LOAD (KVA)
100.00% :TOTAL DEMAND FACTOR
215.7 :TOTAL CONNECTED LOAD (A)
PROVIDE NEW CIRCUIT BREAKERS. 77.7 :TOTAL CONNECTED LOAD (KVA)
NOTES: 232.5 207.5 207.5 :CONNECTED LOAD/PHASE (A)
27.9 24.9 24.9 :CONNECTED LOAD/PHASE (KVA)
53 -- -- -- 11.04 0.00 -- -- Space 54
51 -- -- -- 11.04 0.00 -- -- Space 52
49 AHU-3 (SP-3) (See Note 1) 3 125 A 11.04 0.00 -- -- Space 50
47 -- -- -- 0.00 3.86 -- -- -- 48
45 -- -- -- 0.00 3.86 -- -- -- 46
43 SPARE 3 100 A 0.00 3.86 60 A 3 AHU-3 (RF-3) (See Note 1) 44
41 -- -- -- 0.00 1.00 -- -- -- 42
39 -- -- -- 0.00 1.00 -- -- -- 40
37 SPARE 3 50 A 0.00 1.00 40 A 3 EXISTING - AIR COMPRESSOR 38
35 -- -- -- 1.00 1.00 -- -- -- 36
33 -- -- -- 1.00 1.00 -- -- -- 34
31 EXISTING - AIR COMPRESSOR 3 30 A 1.00 1.00 20 A 3 EXISTING - EF-11 32
29 -- -- -- 1.00 1.00 -- -- -- 30
27 -- -- -- 1.00 1.00 -- -- -- 28
25 EXISTING - 1-EF10 3 15 A 1.00 1.00 20 A 3 EXISTING - EF-13 26
23 Space -- -- 0.00 0.00 -- -- Space 24
21 Space -- -- 0.00 0.00 -- -- Space 22
19 EXISTING - HUMIDIFIER SF2 & SF3 1 20 A 1.00 1.00 20 A 1 EXISTING - HUMIDIFIER SF4 & SF5 20
17 EXISTING - 1-EF21 1 20 A 1.00 0.00 20 A 1 SPARE 18
15 EXISTING - 1-EF15 1 20 A 1.00 0.00 20 A 1 SPARE 16
13 EXISTING - 1-EF14 1 20 A 1.00 1.00 20 A 1 EXISTING - AIR DRYER 14
11 EXISTING - 1-EF12 1 20 A 1.00 1.00 20 A 1 EXISTING - STEAM TRAP PANEL 12
9 EXISTING - 1-UH2 & 1-UH4 1 20 A 1.00 1.00 20 A 1 EXISTING - RECPT - PENTHOUSE 10
7 EXISTING - 1-UH1 & 1-UH3 1 20 A 1.00 1.00 20 A 1 EXISTING - RECPT - PENTHOUSE 8
5 EXISTING - LTG - PENTHOUSE 1 20 A 1.00 1.00 20 A 1 EXISTING - DIRECT DIGITAL CONTROL 6
3 EXISTING - LTG - PENTHOUSE 1 20 A 1.00 1.00 20 A 1 EXISTING - RECPT - PENTHOUSE 4
1 EXISTING - LTG - PENTHOUSE 1 20 A 1.00 1.00 20 A 1 EXISTING - LTG - PENTHOUSE 2
NO DESCRIPTION P TRIP A B C TRIP P DESCRIPTION NO
CKT CIRCUIT BREAKER LOAD (KVA) BREAKER CIRCUIT CKT
A.I.C. RATING EXISTING MOUNTING: SURFACE
BUS RATING: 225 A FED FROM:
RATINGS: 208/120V, 3PH, 4W MAINS TYPE: MLO LOCATION:
EXISTING PANEL ESP-3H
BethKassahun Stamp