Attachment 13: Inspection report Building T15
Apex Companies, LLC 58 H Connecticut Avenue South Windsor, CT 06074 T 860.282.1700 F 860.282.1800 apexcos.com
AAttttaacchhmmeenntt 1133
Asbestos, Lead Paint, PCBs, and Soil Sampling
Inspection Report for the Department of Veterans Affairs (VA) of Central
Western Massachusetts Healthcare System
Building T15
421 North Main Street Leeds, MA 01053-9764
Apex Project No: ACELA-001
December 15, 2017
Prepared for:
Acela Engineering Co
Daniel Witczak, PE, PMP
1275 Glenlivet Drive, Suite 100
Allentown, PA 18106-3107
APEX COMPANIES, LLC
Prepared by:
Ethan T. Platt
Project Manager
Industrial Hygiene Services
TABLE OF CONTENTS
1.0 INTRODUCTION
2.0 ASBESTOS ASSESSMENT AND BULK SAMPLING METHODOLOGY
3.0 INSPECTING FOR ACM
4.0 LABORATORY ANALYSES
5.0 ASBESTOS RESULTS
6.0 LEAD SURVEY (Historic, TCLP, Soil)
7.0 POLYCHLORINATED BIPHENYLS (PCBs) RESULTS
8.0 PCB sOIL RESULTS
9.0 INACCESSIBLE AND LIMITED ACCESS SPACES
10.0 FINDINGS/RECOMMENDATIONS
11.0 DISCLAIMER
FIGURES
Figure 1 Site Location Diagrams – Bulk Sample Locations Figure 2 Combined with Historic Site Location Diagram (from Appendix D)
TABLES
Table 1 NESHAP Sampling Protocol Table 2 Asbestos Sample Analytical Results Table 3 Pb Soil Analytical Results Table 4 PCB Building Sample Analytical Results Table 5 PCB Soil Analytical Results Table 6 Building Composite Total Character Leachate Procedure Soil Analytical Results
APPENDICES
Appendix A Personnel and Laboratory Certifications Appendix B Laboratory Data Sheets and Chain-of Custodies Appendix C Photographs Appendix D Client Provided Historic Reports
VA of Western Massachusetts December 15, 2017
Asbestos, Lead, PCBs, and Soil Survey – Attachment:13 (Building T15) Page 2
1.0 INTRODUCTION
At the request of Acela Engineering Co (Acela) on behalf of the Department of Veterans Affairs (VA) of
Central Western Massachusetts Healthcare System(VA), Apex Companies, LLC (Apex) has conducted an inspection of Building T15 on the VA Campus located at 421 North Main Street in Leeds, Massachusetts. The building was unoccupied at the time of the survey and was inspected for the presence of asbestos-containing materials (ACMs), lead based paint via Total Characteristic Leachate
Procedure (TCLP), Polychlorinated biphenyls (PCBs), and soil samples were collected and analyzed for the presence of lead (Pb) and PCBs along the building ‘drip line’ where possible. The survey services were conducted on November 6 through 10, 2017.
Mr. Ethan T. Platt (Apex) was the inspector performing the inspection activities at the project site. Mr.
Platt is a Massachusetts Department of Labor Standards (MADOLS)-licensed asbestos Consultant
Inspector (License No. AM000219). Copies of Mr. Platt’s certifications are provided in Appendix A.
Apex conducted a visual inspection of the interior and exterior areas of the building. During the visual inspection, Apex identified and collected eleven (11) samples of suspect ACMs, one (1) sample for TCLP lead, one (1) soil sample for lead, one (1) soil sample for PCBs, and four (4) bulk sample for PCBs.
While Apex made every attempt to seek out and sample all suspect materials, due to limitations, there exists the possibility that unidentified materials may remain in the building. At the time of demolition, any materials not identified in this report that is uncovered should be considered to be an ACM unless testing proves otherwise.
In addition to Apex’s inspection the VA supplied a historic report produced by Mabbett & Associates, Inc.
(2010). Where feasible this historic report has been incorporated into this report.
The remaining building’s components, as best that can be safely assessed were inspected for suspect materials. All of the samples collected were analyzed via polarized light microscopy (PLM) to determine the presence of asbestos.
2.0 ASBESTOS ASSESSMENT AND BULK SAMPLING METHODOLOGY
Survey and assessment protocols used were based on those adopted by the United States
Environmental Protection Agency (EPA) as detailed in the National Emission Standard for Hazardous Air
Pollutants (NESHAP) 40 Code of Federal Regulations (CFR) 61, Subpart M. Mr. Platt conducted the on-site inspection and assessments.
Asbestos bulk samples were collected and analyzed using the EPA’s NESHAP protocol as follows:
• Sampling locations were initially chosen in a randomly distributed;
• Suspended ceiling tiles were moved slowly in a horizontal position;
• The sample areas were wetted (not saturated) during sampling to minimize fiber release;
• The suspect ACM was sampled using a utility knife, wood chisels, coring tools, or forceps. The tool that minimized the disturbance to the sample material, was least likely to cause fiber release, and was most efficient for sampling the particular material was used;
• All layers of suspected ACMs were sampled, with sample integrity maintained;
• The bulk sample size was approximately two square centimeters (cm2) or smaller;
Asbestos, Lead, PCBs, and Soil Survey – Attachment:13 (Building T15) Page 3
• Wherever possible, samples were collected from damaged areas to minimize fiber release;
• Each sample was placed in a clear plastic container and the outside wet-wiped, sealed, and labeled with a unique sample number. This number, along with other pertinent information, was recorded on the bulk sample chain of custody and field form;
• The sampling tool was cleaned with a damp disposable towel between sample collection.
The sampling protocol established by NESHAP was used to determine the required number of samples for this survey based on function (surfacing, thermal system insulation, or miscellaneous materials) and homogeneous building materials. A homogeneous area is defined as an area where a suspect material is uniform in texture, color, and appears to have been installed at the same time. Materials appearing to be identical but determined by the inspector to have been installed at different time periods were treated as different suspect materials.
The NESHAP protocol was used to determine functional areas, and subsequent, homogeneous areas of construction in the building.
Three forms of asbestos are typically found in buildings:
• sprayed- or troweled-on surfacing materials (spray-on fireproofing and plaster);
• thermal system insulation (insulation on pipes, boilers and other mechanical equipment); and
• miscellaneous materials such as floor tiles, ceiling tiles, roofing materials, drywall composition, window caulking / glazing, etc.
NESHAP recommends the collection of a minimum number of samples for each suspect ACM. Apex follows the NESHAP sampling protocol for each survey conducted. In addition, Apex generally collects a minimum of one to three samples per suspect homogeneous material. However, in cases where the material is hidden beneath layers the sample numbers are often reduced.
Identification of types of materials and the number of samples collected during the Apex survey, which is based on the NESHAP sampling protocol is identified in Table 1. The suspect and accessible materials that were observed in the facility were sampled per this protocol. Apex developed a sampling strategy following a walk-through visual inspection of the accessible areas of the building. This allowed the inspector to evaluate the construction of the building, as well as identify suspect homogeneous ACMs for sampling purposes.
Apex made every attempt to visually assess the entire structure included in this survey, as well as to collect samples of all suspect materials identified. However, some areas of the building were not inspected due to being inaccessible due to occupancy or without extensive demolition (such as wall interiors) and areas where safety would be compromised by entering (such as confined spaces or inside active machinery). Any new materials found in these areas during renovations or demolition is to be considered ACMs until sampling and testing confirms otherwise.
Once homogeneous suspect materials were identified, Apex began the collection of these materials for submission to the laboratory.
Asbestos, Lead, PCBs, and Soil Survey – Attachment:13 (Building T15) Page 4
3.0 INSPECTING FOR ACM
This inspection and sampling was conducted on an area-by-area basis. Materials that were considered suspect were identified and the number of samples to be collected of these suspect materials was determined by the inspector using NESHAP protocols. As defined by NESHAP, suspect materials include the following building material types:
• surfacing materials - including plaster, spray-applied or troweled-on wall/ceiling coatings;
• thermal system insulation (TSI) - including pipe insulation, duct insulation, boiler lagging; and
• miscellaneous materials - including ceiling tile, floor tiles and mastics, gaskets (if accessible), fire doors, and wallboard/spackling compound.
Suspect materials that are homogeneous in nature (i.e., uniform in color and texture) were identified, touched to determine friability, and sampled by removing a small piece that was then placed in a labeled container. For a given homogeneous area, one or more samples were collected in a randomly distributed manner in accordance with NESHAP provisions (40 CFR 61). Unless specifically referenced, materials not considered by the NESHAP rules as suspect ACMs were not addressed by Apex during this survey.
Several suspect ACMs identified at the building warranted special scrutiny or otherwise required special consideration. These materials were:
• Joint Compound/Sheetrock: if sheetrock (wallboard and ceiling board) and its associated joint compound were considered suspect ACM and sampled separately in accordance with OSHA requirements. If either component was found to contain more than one percent asbestos, the entire wall system would be considered ACM; and
• Vinyl floor tiles and mastics: If floor tiles and underlying mastics were considered suspect ACM.
Each flooring material and its associated mastic were sampled separately. If either component was found to contain greater than one percent asbestos, then only that material was considered ACM.
However, if positive mastic adheres to floor tile, the floor tile must be considered contaminated.
Based on this observation, the characterization of the homogenous material underneath (i.e., tile or mastic), if any, was extrapolated to the entire floor surface of that area. The base flooring was examined to the subflooring.
4.0 LABORATORY ANALYSES
In order to determine whether the materials are asbestos containing (i.e., contain more than one percent asbestos as defined by the EPA, or containing ‘1% or more’ per MADEP 310 CMR 7.15) EMSL Analytical, Inc. in Cinnaminson, New Jersey analyzed samples for asbestos content. EMSL is a National Voluntary
Laboratory Accreditation Program (NVLAP)-accredited laboratory. Sample designations, gross descriptions, and analytical results are provided in Table 2. Laboratory analytical reports and field sampling logs are presented in Appendix B.
Asbestos fiber content is estimated by optically comparing the quantity of non-asbestos material to asbestos fibers utilizing polarized light microscopy/dispersion staining (PLM/DS). The lower limit of reliable detection using PLM is 1%. Samples that contain 1% or more asbestos are reported in percent
Asbestos, Lead, PCBs, and Soil Survey – Attachment:13 (Building T15) Page 5 ranges. Samples that contain asbestos in a concentration lower than the limit of reliable detection (<1%) are reported as “<1%”. Samples in which no asbestos is observed are reported as “None Detected”.
EMSL analyzed ten (10) of the fourteen (14) collected bulk samples via PLM.
5.0 ASBESTOS RESULTS
Asbestos-containing building materials were detected in Building T15 of the VA campus site located at
421 North Main Street Leeds, Massachusetts. A material is considered by the EPA to be asbestos-containing if at least one sample collected from the homogeneous area shows asbestos present in an amount greater than one percent (>1%), and the Massachusetts DEP further defines the asbestos containing material as ‘1% or more’ per MADEP 310 CMR 7.15. The full sample list is provided in Table
2. A copy of the laboratory ACM sample results is provided in Appendix B.
The following building materials contained ≥ 1 % asbestos:
Sample # 03a Confirmatory Sample – Window Glazing
2% Chrysotile
~100 lf
Sample # 05a-c Metal to wood siding sealer
7% Chrysotile
~200 sf – at the metal roof to sheet intersections/overlaps
Historic Sample # 02c Window Glazing
2% Chrysotile
~320 lf
Asbestos, Lead, PCBs, and Soil Survey – Attachment:13 (Building T15) Page 6
6.0 LEAD SURVEY (Historic, TCLP, Soil)
Historic Report
In 2010 Mabbett & Associates conducted a full Lead Paint inspection via XRF. Lead was found to be present (see below table). This report is attached as Appendix D.
Table 5 - Northampton VA Medical
Reading
No.
Floor Location
Substrate and
Component Side Condition Color
Results
(mg/cm2)
2696 First Exterior Wood Window Sash South Peeling White 10.7
2697 First Exterior Wood Wall (Exterior) South Peeling Gray 4.9
2698 First Exterior Wood Window Casing South Peeling White 14.9
2699 First Exterior Wood Door South Peeling Brown 5.2
2700 First Exterior Wood Door Casing South Peeling White 16.9
2701 First Exterior Metal Security Bars South Peeling Brown 1.6
2702 First Exterior Metal Wall (Exterior) East Peeling Gray 4.4
2703 First Exterior Metal Roof East Peeling Brown 2.6
2704 First Exterior Wood Trim East Peeling Gray 4.5
2705 First Exterior Wood Column South Peeling Gray 5.5
2706 First Exterior Wood Beam South Peeling Gray 6.2
2707 First Exterior Wood Door North Cracked Green 0.16
2709 First Exterior Metal Beam East Fair Brown 0.8
The HUD/EPA standard for lead-based paint of equal to or greater than 1.0 mg/cm2 by XRF.
TCLP Lead Assessment
Apex collected building composite samples to represent the building’s construction and components. This composite sample was collected to determine whether components of either building which is slated for demolition have hazardous levels of lead-based paint. This TCLP analysis is conducted to determine whether debris generated from demolition needs to be disposed of as hazardous lead waste. The EPA has determined that if the result of the analysis is more than 5.0 milligram per liter (mg/L) then the waste needs to be disposed of as lead-contaminated waste.
The representative composite sample of building materials was collected, and submitted to the laboratory for analysis by EMSL. The results of all TCLP are summarized in Table 6:
The TCLP laboratory result for lead is reported 0.72 mg/L for Building T15. The result does not exceed the regulatory threshold of 5.0 mg/L. The TCLP laboratory report is provided in Appendix B.
It is important to note that the OSHA 29 CFR 1926.62 (the Lead in Construction Standard) applies to demolition activity that disturbs any lead-containing paint. Therefore, paints that were not classified as lead-based paint but did have a lead detection are regulated under this standard in addition to paints classified as lead-based paint. Because several paints did contain low levels of lead, the OSHA Lead in
Asbestos, Lead, PCBs, and Soil Survey – Attachment:13 (Building T15) Page 7
Construction Standard should be utilized during building demolition.
The Lead paint is present in the building as sampled via XRF.
Please refer to the report in Appendix D
Lead in Soil
Lead is naturally present in all soils. It occurs generally in the range of 15 to 40 parts lead per million parts of soil (ppm), or 15 to 40 milligrams lead per kilogram of soil (mg/kg). Pollution can increase soil lead levels to several thousand ppm; the major cause of soil lead contamination in populated areas is the weathering, chipping, scraping, sanding, and sand-blasting of structures bearing lead-based paint.
In the past, significant causes of soil contamination by lead included the use of tetraethyl lead as an anti-knock ingredient in gasoline and lead arsenate as an insecticide in fruit orchards. Automotive lead emissions have effectively ceased with the phasing out of leaded fuels, and with the development of more effective pesticides and Integrated Pest Management (IPM), lead arsenate is no longer in use.
Unfortunately, lead persists in soil for many hundreds of years and past use of these products continues to present problems in some areas.
Soil lead becomes a health risk when directly ingested or inhaled as dust. Garden produce, which has accumulated lead in its tissue or has soil particles adhering to it, can also be a hazard if eaten. Lead poisoning is a particular concern for young children (under 6) because their rapidly developing bodies are very sensitive to the effects of lead, and their play habits tend to increase exposure.
Under 40 CFR 261 the regulatory threshold is 5.0 mg/L (or 5,000 mg/kg). The four (3) drip line samples were found to be below the threshold. The results are summarized in Table 3 below.
TABLE 3
TCLP Lead in Soil for Building T15
Sample Number Location Result (mg/l)
Pb-T15-01 west side drip line < 0.40
Asbestos, Lead, PCBs, and Soil Survey – Attachment:13 (Building T15) Page 8
7.0 POLYCHLORINATED BIPHENYLS (PCBS) RESULTS
Many building products produced from the 1950’s through the 1970’s were manufactured with PCBs as a key ingredient because of their non-flammability, chemical stability, high boiling point, and electrical and thermal insulating properties. PCBs were also added to many building products as a plasticizer, which increased their flexibility. Although the use of products with PCBs is unauthorized per Section 6(e)(2) of the Toxics Substances Control Act (TSCA) and in Chapter 40, Section 761.20 of the Code of Federal
Regulations (CFR), there is no regulatory requirement to test products in use to determine their PCB concentration.
If PCBs are detected in building materials at concentrations between 1 ppm and 50 ppm and the building materials meet the definition of a PCB Excluded Product as defined in 40 CFR 761.3, then the
Massachusetts Department of Environmental Protection (DEP) recommends that the building materials be removed.
Building materials containing PCBs at concentrations greater than or equal to 50 parts per million (ppm) are not authorized for use under Section 6(3)(2) of TSCA and must be removed and properly disposed of as PCB Bulk Product Waste in accordance with 40 CFR 761.62.
Apex collected samples from different materials in the building. These samples were also analyzed for
PCBs in accordance with EPA 40 CFR 761. Refer to Table 4 - PCB Bulk Sample Results. The results for
Table 4 are summarized below:
Sample Number Location / Material
Total result mg/Kg
(see Appendix B and Table 4)
ND = None Detected
PCB-B-T15-01 Exterior Metal siding paint ND
PCB-B-T15-02 Exterior window glazing ND
PCB-B-T15-03 Exterior wood siding paint ND
PCB-B-T15-04 Metal to wood siding sealer ND
The bulk material samples were submitted to EMSL Analytical, Inc., a certified laboratory, for analysis.
The samples were prepared and analyzed in accordance with the EPA analytical method SW-846 3540C.
Refer to Appendix B for the laboratory analytical reports.
8.0 PCB SOIL RESULTS
Representative soil samples were collected from each of building ‘drip-lines’ where possible submitted for laboratory analysis. Collected soil samples were placed within laboratory provided pre-preserved glassware and submitted to EMSL for analysis for PCBs.
Laboratory samples were analyzed in accordance EPA SW-846 3550B/8082A/608 method.
The PCB regulations separate PCB waste into two categories, with different disposal requirements for each. When assessing your building, it is important to determine what types of PCB waste you will be
Asbestos, Lead, PCBs, and Soil Survey – Attachment:13 (Building T15) Page 9 disposing of.
A PCB-containing material is considered PCB bulk product waste if the concentration of PCBs in the material is greater than or equal to (≥) 50 ppm (see, 40 C.F.R. § 761.3). PCB bulk product waste includes waste derived from manufactured products containing PCBs in a non-liquid state where the concentration at the time of designation for disposal is ≥ 50 ppm PCBs (see, 40 C.F.R. §§ 761.3 & 761.62). Additionally, the definition of PCB bulk product waste includes building materials that have been coated or serviced with PCBs. That is, masonry, wood, metals, and other building materials that are purposely coated with a
PCB-containing material are regulated as PCB bulk product waste if the material coating the building materials contains PCBs at concentrations ≥ 50 ppm.
If PCBs have contaminated either the surrounding building materials or adjacent soil, these materials are considered PCB remediation waste. PCB remediation waste is subject to the cleanup and disposal requirements according to 761.61.
Although state, local, and federal regulations may allow for the disposal of materials containing PCBs at concentrations of <50 ppm, some disposal facilities will not accept waste with any concentration of PCBs.
When finding a disposal facility, you should ensure that the facility is able and willing to accept the waste.
Based on the soil analytical data, a reportable condition under the MCP and under 40CFR761 does not exist and the soils may be re-used. A summary of the soil sample results are provided in Table 5 (which is summarized below). A copy of the laboratory analytical report is provided in Appendix B.
TABLE 5 summery
PCB in Soil for Building T15
ND = None Detected
PCB-T15-01 West side drip line ND
9.0 INACCESSIBLE AND LIMITED ACCESS SPACES
Every reasonable attempt was made to locate ACM in the areas surveyed. No areas were determined to be inaccessible. However, there are always the potential of concealed areas/materials that are considered likely to contain suspect ACMs.
10.0 FINDINGS/RECOMMENDATIONS
Materials suspected of potentially containing asbestos were identified during the inspection and sampled for asbestos content. According to the laboratory analysis, there is several building materials found to contain 1% or greater asbestos. Table 2, the Homogeneous Material List, provides a complete list of the identified suspect ACMs.
Since hidden ACMs maybe present, actions should be taken to prevent fiber release and to minimize
Asbestos, Lead, PCBs, and Soil Survey – Attachment:13 (Building T15) Page 10 exposure to the customers, building owners, employees and demolition contractors to asbestos fibers.
The following are Apex’s recommendations for management of these ACMs.
• The renovation/demolition contractor and other subcontractors working within the building should be made aware of the locations of the ACMs and the possibility of concealed suspect ACMs that could be found during renovation/demolition activities. They should be advised not to disturb the identified ACMs or suspect ACMs.
• OSHA requirements do apply when trace amounts of asbestos are found. OSHA requires that any detectable level of asbestos is hazardous, and workers must not exceed permissible exposure limits during removal. Apex recommends that any material with <1% asbestos be treated and handled as if it were an ACM up until the point of disposal. ACM with concentration
<1% do not require to be disposed of as asbestos, even under OSHA regulation.
• Any concealed building materials discovered during renovation/demolition activities, which are suspected to contain asbestos, should be sampled by a MA DLS-licensed asbestos inspector and analyzed by an NVLAP-accredited laboratory to confirm the absence or presence of asbestos prior to the disturbance of such materials. If the materials are found to contain asbestos, applicable local, state and federal regulations will apply.
• During planned future demolition activities that will impact the identified ACMs in the project site, they should be properly removed by a MA DLS-licensed asbestos abatement contractor prior to construction activities. Abatement activities must be performed in compliance with applicable local, state, and federal requirements.
• Any construction waste or debris leaving the site should be tested for waste characterization and disposal purposes.
11.0 DISCLAIMER
The results, findings, conclusions, and recommendations expressed in this report are based only on conditions that were noted during the November 6 through November 10, 2017, inspection of Building
T15 of the VA of Western Massachusetts, located in Leeds Massachusetts. Apex’s selection of sample locations and frequency of sampling was based on Apex’s observations and the assumption that like materials in the same area are homogeneous in content, so far as access was granted.
This report is for the sole benefit of Acela Engineering and the VA of Western Massachusetts, and may not be relied upon by any other person or entity. The findings and conclusions for this work are limited in time and scope to the circumstances. Implementation or use of the recommendations, findings, or conclusions from this work in no way assures the elimination of present or future liability of fulfillment of the property owner’s obligation under any local, state, or federal laws.
The report is designed to aid the building owner, architect, construction manager, general contractors, Asbestos, Lead, PCBs, and Soil Survey – Attachment:13 (Building T15) Page 11 and potential asbestos abatement contractors in locating ACM. Under no circumstances is the report to be utilized as a bidding document or as a project specification document since it does not have all the components required to serve as an Asbestos Project Design document or an Abatement
Work Plan. The quantities of ACMs identified in this report are only estimates and should not be used for bidding or developing specifications for abatement. It is the responsibility of the asbestos abatement contractor to calculate actual quantities and develop the abatement plan accordingly.
Our professional services have been performed, our findings obtained, and our conclusions and recommendations prepared in accordance with customary principles and practices in the fields of environmental science and engineering. This statement is in lieu of other statements either expressed or implied. This report does not warrant against future operations or conditions, nor does it warrant against operations or conditions present of a type or at a location not investigated.
Any conditions or materials that could not be visually identified on the surface were not inspected and may differ from those conditions or materials noted. It was not within the scope of the inspection to remove surface materials to investigate portions of the structure or materials that lay beneath the surface.
FIGURES
TABLES
TABLE 1
NESHAP SAMPLING PROTOCOL
Type of Material Estimated Quantity Required Samples
Sprayed or Troweled-on Surfacing Material
Greater than 5,000 ft2 7
Between 1,000 ft2 and 5,000 ft2 5
Less than 1,000 ft2 3
Thermal System Insulation All Quantities 3
Miscellaneous Materials All Quantities
Per NESHAP, these materials must be sampled “in a manner sufficient to determine whether or not they contain asbestos.” Apex will generally collect 1 to 3 samples of such material based upon the inspector’s judgment.
NOTE: These sampling protocol quantities are per functional area and/or homogeneous area.
TABLE 2
ASBESTOS SAMPLE RESULTS
MATERIAL TYPE LOCATION
SAMPLE
IDs
ASBESTOS
CONTENT
Confirmatory sample – 2x4 suspended ceiling tiles
Office 01a None Detected
Ceiling board above Office SCT Office 02a-c None Detected
Confirmatory sample – Window glazing Exterior 03a 2% Chrysotile
Tar paper under wood siding Exterior 04a-b None Detected
Metal to wood siding sealer Exterior 05a-c 7% Chrysotile
ACM Table from 2010 Report
2x4 suspended ceiling tiles Office 01a-c None Detected
Window glazing Exterior
02a-b None Detected
0502c-c 2% Chrysotile
TABLE 3
TCLP Lead in Soil for Building T15
Pb-T15-01 west side drip line < 0.40
Table 4
PCB Bulk Sample Results
Sample # Description
PCB-B-T15-01
Building T15 – Exterior Metal Siding Paint
PCB Parameter Sample Results Detection Limit Units Method
Aroclor-1016 ND 0.96 mg/kg dry SW-846 3540C
Aroclor-1221 ND 0.96 mg/kg dry SW-846 3540C
Aroclor-1232 ND 0.96 mg/kg dry SW-846 3540C
Aroclor-1242 ND 0.96 mg/kg dry SW-846 3540C
Aroclor-1248 ND 0.96 mg/kg dry SW-846 3540C
Aroclor-1254 ND 0.96 mg/kg dry SW-846 3540C
Aroclor-1260 ND 0.96 mg/kg dry SW-846 3540C
Aroclor-1262 ND 0.96 mg/kg dry SW-846 3540C
Aroclor-1268 ND 0.96 mg/kg dry SW-846 3540C
Sample # Description
PCB-B-T15-02
Building T15 – Exterior Window Glazing
PCB Parameter Sample Results Detection Limit Units Method
Aroclor-1016 ND 0.96 mg/kg dry SW-846 3540C
Aroclor-1221 ND 0.96 mg/kg dry SW-846 3540C
Aroclor-1232 ND 0.96 mg/kg dry SW-846 3540C
Aroclor-1242 ND 0.96 mg/kg dry SW-846 3540C
Aroclor-1248 ND 0.96 mg/kg dry SW-846 3540C
Aroclor-1254 ND 0.96 mg/kg dry SW-846 3540C
Aroclor-1260 ND 0.96 mg/kg dry SW-846 3540C
Aroclor-1262 ND 0.96 mg/kg dry SW-846 3540C
Aroclor-1268 ND 0.96 mg/kg dry SW-846 3540C
Sample # Description
PCB-B-T15-03
Building T15 – Wood Siding Paint
PCB Parameter Sample Results Detection Limit Units Method
Aroclor-1016 ND 0.98 mg/kg dry SW-846 3540C
Aroclor-1221 ND 0.98 mg/kg dry SW-846 3540C
Aroclor-1232 ND 0.98 mg/kg dry SW-846 3540C
Aroclor-1242 ND 0.98 mg/kg dry SW-846 3540C
Aroclor-1248 ND 0.98 mg/kg dry SW-846 3540C
Aroclor-1254 ND 0.98 mg/kg dry SW-846 3540C
Aroclor-1260 ND 0.98 mg/kg dry SW-846 3540C
Aroclor-1262 ND 0.98 mg/kg dry SW-846 3540C
Aroclor-1268 ND 0.98 mg/kg dry SW-846 3540C
PCB Bulk Sample Results Continued
PCB-B-T15-04
Building T15 – Metal to Wood Siding Sealer
PCB Parameter Sample Results Detection Limit Units Method
Aroclor-1016 ND 0.95 mg/kg dry SW-846 3540C
Aroclor-1221 ND 0.95 mg/kg dry SW-846 3540C
Aroclor-1232 ND 0.95 mg/kg dry SW-846 3540C
Aroclor-1242 ND 0.95 mg/kg dry SW-846 3540C
Aroclor-1248 ND 0.95 mg/kg dry SW-846 3540C
Aroclor-1254 ND 0.95 mg/kg dry SW-846 3540C
Aroclor-1260 ND 0.95 mg/kg dry SW-846 3540C
Aroclor-1262 ND 0.95 mg/kg dry SW-846 3540C
Aroclor-1268 ND 0.95 mg/kg dry SW-846 3540C
1 μg /kg = 0.001 mg/kg : 1mg/kg = 1,000 μg/kg
Table 5
PCB Soil Sample Results
PCB-T15-01
Building T15 – West side drip line soil
PCB Parameter Sample Results Detection Limit Units Method
Aroclor-1016 ND 0.019 mg/kg dry SW-846 3540C
Aroclor-1221 ND 0.019 mg/kg dry SW-846 3540C
Aroclor-1232 ND 0.019 mg/kg dry SW-846 3540C
Aroclor-1242 ND 0.019 mg/kg dry SW-846 3540C
Aroclor-1248 ND 0.019 mg/kg dry SW-846 3540C
Aroclor-1254 ND 0.019 mg/kg dry SW-846 3540C
Aroclor-1260 ND 0.019 mg/kg dry SW-846 3540C
Aroclor-1262 ND 0.019 mg/kg dry SW-846 3540C
Aroclor-1268 ND 0.019 mg/kg dry SW-846 3540C
1 μg /kg = 0.001 mg/kg : 1mg/kg = 1,000 μg/kg
TABLE 6
TCLP LEAD SAMPLING RESULTS
Sample Number Location of Material TCLP Lead Concentration
TCLP-T15 Building T15: Building Composite sample 0.72 mg/L
The TCLP laboratory result for lead is reported at 0.72 mg/L for Building T15. The result does not exceed the regulatory threshold of 5.0 mg/L. The TCLP laboratory report is provided in Appendix B.
APPENDIX A
Certifications
AIHA Laboratory Accreditation Programs, LLC acknowledges that
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077
Laboratory ID: 100194 along with all premises from which key activities are performed, as listed above, has fulfilled the requirements of the AIHA Laboratory Accreditation Programs (AIHA-LAP), LLC accreditation to the ISO/IEC 17025:2005 international standard, General Requirements for the Competence of Testing and Calibration Laboratories in the following:
LABORATORY ACCREDITATION PROGRAMS
INDUSTRIAL HYGIENE Accreditation Expires: September 01, 2018 ENVIRONMENTAL LEAD Accreditation Expires: September 01, 2018 ENVIRONMENTAL MICROBIOLOGY Accreditation Expires: September 01, 2018 FOOD Accreditation Expires:
UNIQUE SCOPES Accreditation Expires:
Specific Field(s) of Testing (FoT)/Method(s) within each Accreditation Program for which the above named laboratory maintains accreditation is outlined on the attached Scope of Accreditation. Continued accreditation is contingent upon successful on-going compliance with ISO/IEC 17025:2005 and AIHA-LAP, LLC requirements. This certificate is not valid without the attached Scope of Accreditation. Please review the AIHA- LAP, LLC website (www.aihaaccreditedlabs.org) for the most current Scope.
William Walsh, CIH Chairperson, Analytical Accreditation Board
Cheryl O. Morton Managing Director, AIHA Laboratory Accreditation Programs, LLC
Revision 15: 03/30/2016 Date Issued: 08/31/2016 http://www.aihaaccreditedlabs.org/
Effective: 04/10/2015 100194_Scope_IHLAP (Method Addition)_2017_04_12
AIHA Laboratory Accreditation Programs, LLC
SCOPE OF ACCREDITATION
EMSL Analytical, Inc. Laboratory ID: 100194 200 Route 130 North, Cinnaminson, NJ 08077 Issue Date: 04/13/2017
The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory’s current accreditation status for the particular field(s) of testing/Methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation.
Industrial Hygiene Laboratory Accreditation Program (IHLAP)
Initial Accreditation Date: 02/01/1989
IHLAP Scope Category
Field of Testing (FoT) (FoTs cover all relevant
IH matrices)
Technology sub-type/ Detector
Published Reference Method/Title of In-house Method
Method Description or Analyte
(for internal methods only)
Chromatography Core
Gas Chromatography
GC/FID
NIOSH 1003 Modified
NIOSH 1005
NIOSH 1400 Modified NIOSH 1500 Modified NIOSH 1501 Modified NIOSH 1550 Modified NIOSH 1603 Modified NIOSH 2000 Modified
GC/ECD
NIOSH 5502 Modified NIOSH 5503 Modified NIOSH 5510 Modified OSHA 1010 Modified
GC/MS GC/MS EPA TO-15
Gas Chromatography (Diffusive Samplers) NIOSH 1501 Modified
Ion Chromatography (IC)
NIOSH 6004 Modified
NIOSH 6011
NIOSH 7903
OSHA ID-165SG
OSHA ID-214
OSHA ID-215 Modified
Liquid Chromatography HPLC/FL NIOSH 2016 Modified HPLC/UV NIOSH 5506 Modified HPLC/MS NIOSH 9111 Modified
Spectrometry Core Atomic Absorption CVAA NIOSH 6009 Modified
Effective: 04/10/2015 100194_Scope_IHLAP (Method Addition)_2017_04_12
IHLAP Scope Category
Field of Testing (FoT) (FoTs cover all relevant
IH matrices)
Technology sub-type/ Detector
Published Reference Method/Title of In-house Method
Method Description or Analyte
(for internal methods only)
Spectrometry Core
Atomic Absorption
CVAA
OSHA ID-140 Modified
OSHA ID-145
FAA NIOSH 7082
GFAA NIOSH 7105
Inductively-Coupled Plasma
ICP/MS NIOSH 7300 Modified ICP/AES NIOSH 7300 Modified
X-ray Diffraction (XRD) NIOSH 7500 Modified OSHA ID-142 Modified
UV/VIS (Colorimetric) NIOSH 6010 Modified
Asbestos/Fiber Microscopy Core
Polarized Light Microscopy (PLM) EPA 600/R-93/116
Phase Contrast Microscopy (PCM) NIOSH 7400
Transmission Electron Microscopy (TEM)
EPA AHERA - 40 CFR
Part 763
EPA AHERA Method (40 CFR 763, Subpart E, Appendix A, Mandatory Method
NIOSH 7402
Miscellaneous Core Gravimetric
NIOSH 0500
NIOSH 0600
NIOSH 5524
Thermo-optical Analysis
(TOA) NIOSH 5040
Beryllium Testing Inductively-Coupled Plasma ICP/MS NIOSH 7300
NIOSH 7303
A complete listing of currently accredited Industrial Hygiene laboratories is available on the AIHA-LAP, LLC website at:
http://www.aihaaccreditedlabs.org http://www.aihaaccreditedlabs.org/
APPENDIX B
Laboratory Data Sheets and Chain-of-Custodies
Laboratory Data Sheets and Chain-of Custodies
Asbestos
200 Route 130 North Cinnaminson, NJ 08077
Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com
041732758EMSL Order:
Customer ID: APEX30
Customer PO:
Project ID:
Attention: Phone:Ethan Platt (860) 282-1700
Fax:Apex Companies, LLC (860) 282-1800
Received Date:58H Connecticut Ave. 11/13/2017 9:00 AM
Analysis Date:South Windsor, CT 06074 11/17/2017
Collected Date: 11/06/2017
Project: ACELA-001 / Building # T15
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
01A
041732758-0001
None DetectedNon-fibrous (Other)10%Cellulose
Min. Wool
60%
30%
Brown
Fibrous
Homogeneous
Bldg T15 Office -
Conformity 2 x 4 SCT
HA: 1
02A
041732758-0002
None DetectedNon-fibrous (Other)93%Cellulose7%Gray
Fibrous
Homogeneous
Bldg T15 Office -
Ceiling Bend above
SCT
HA: 2
02B
041732758-0003
None DetectedNon-fibrous (Other)50%Cellulose50%Brown/Gray
Fibrous
Homogeneous
Bldg T15 Office -
Ceiling Bend above
SCT
HA: 2
02C
041732758-0004
None DetectedNon-fibrous (Other)50%Cellulose50%Brown/Gray
Fibrous
Homogeneous
Bldg T15 Office -
Ceiling Bend above
SCT
HA: 2
03A
041732758-0005
2% ChrysotileNon-fibrous (Other)98%Gray
Fibrous
Homogeneous
Bldg T15 Office -
Conformity Sample
Ext Window Glazing
HA: 3
04A
041732758-0006
None DetectedNon-fibrous (Other)10%Cellulose90%Black
Fibrous
Homogeneous
Bldg T15 Office - Tar
Paper under Wood
Siding
HA: 4
04B
041732758-0007
None DetectedNon-fibrous (Other)10%Cellulose90%Black
Fibrous
Homogeneous
Bldg T15 Office - Tar
Paper under Wood
Siding
HA: 4
04C
041732758-0008
None DetectedNon-fibrous (Other)10%Cellulose90%Black
Fibrous
Homogeneous
Bldg T15 Office - Tar
Paper under Wood
Siding
HA: 4
05A
041732758-0009
7% ChrysotileNon-fibrous (Other)93%Black
Fibrous
Homogeneous
Bldg T15 Office -
Metal to Wood Block
Sealant
HA: 5
05B
041732758-0010
Positive Stop (Not Analyzed)Bldg T15 Office -
Metal to Wood Block
Sealant
HA: 5
05C
041732758-0011
Positive Stop (Not Analyzed)Bldg T15 Office -
Metal to Wood Block
Sealant
HA: 5
Initial report from: 11/17/2017 15:43:00
Page 1 of 2ASB_PLM_0008_0001 - 1.78 Printed: 11/17/2017 5:48 PM
200 Route 130 North Cinnaminson, NJ 08077
Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com
041732758EMSL Order:
Customer ID: APEX30
Customer PO:
Project ID:
Analyst(s)
Mark Tate (9) Benjamin Ellis, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Depew, NY
Initial report from: 11/17/2017 15:43:00
Page 2 of 2ASB_PLM_0008_0001 - 1.78 Printed: 11/17/2017 5:48 PM
OrderID: 041732758
Building Composite TCLP (Lead)
Client Sample Description ConcentrationLab ID Analyzed Lead
Collected
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (856) 303-2500 / (856) 786-5974 http://www.EMSL.com cinnaminsonleadlab@emsl.com
Attn: Ethan Platt Apex Companies, LLC 58H Connecticut Ave.
South Windsor, CT 06074
Received: 11/13/17 10:30 AM
ACELA-001
Fax: (860) 282-1800 Phone: (860) 282-1700
Project:
Collected:
Test Report: Toxicity Characteristic Leaching Procedure (SW846, 1311/7420)
201711719 CustomerID: APEX30 CustomerPO:
ProjectID:
EMSL Order:
Site: Bldg T7 201711719-0001T7 94 mg/L11/14/2017
Site: Bldg T8 201711719-0002T8 50 mg/L11/14/2017
Site: Bldg T12 201711719-0003T12 27 mg/L11/14/2017
Site: Bldg T13 201711719-0004T13 48 mg/L11/14/2017
Site: Bldg T15 201711719-0005T15 0.72 mg/L11/14/2017
Site: Bldg 27 201711719-000627 <0.40 mg/L11/15/2017
Site: Bldg 34 201711719-000734 78 mg/L11/15/2017
Site: Bldg 35 201711719-000835 <0.40 mg/L11/15/2017
Site: Bldg 40 201711719-000940 <0.40 mg/L11/15/2017
Site: Bldg 41 201711719-001041 53 mg/L11/15/2017
Site: Bldg 42 201711719-001142 <0.40 mg/L11/16/2017
Site: Bldg 52 201711719-001252 <0.40 mg/L11/16/2017
Site: Bldg 63 201711719-001363 <0.40 mg/L11/16/2017
Phillip Worby, Lead Laboratory Manager or other approved signatory
Test Report ChmSnglePrm/nQC-7.32.3 Printed: 11/20/2017 9:29:41 AM
The test results contained within this report meet the requirements of NELAC unless otherwise noted. This report relates only to those items tested. Samples received in good condition unless otherwise noted. Quality Control Data associated with this sample set is within acceptable limits, unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit.
Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ NELAP Certifications: NJ 03036, NY 10872, PA 68-00367
Initial report from 11/20/2017 09:29:41 http://www.EMSL.com mailto:cinnaminsonleadlab@emsl.com
OrderID: 201711719
OrderID: 201711719
TCLP Lead in Soil
Client Sample Description ConcentrationLab ID Analyzed Lead
Collected
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (856) 303-2500 / (856) 786-5974 http://www.EMSL.com cinnaminsonleadlab@emsl.com
Attn: Ethan Platt Apex Companies, LLC 58H Connecticut Ave.
South Windsor, CT 06074
Received: 11/15/17 10:30 AM
ACELA-001 / Bldg T15
Fax: (860) 282-1800 Phone: (860) 282-1700
Project:
11/14/2017Collected:
Test Report: Toxicity Characteristic Leaching Procedure (SW846, 1311/7420)
201711849 CustomerID: APEX30 CustomerPO:
ProjectID:
EMSL Order:
Site: West Side 201711849-0001Pb-T15-01 <0.40 mg/L11/21/201711/14/2017
Phillip Worby, Lead Laboratory Manager or other approved signatory
Test Report ChmSnglePrm/nQC-7.32.3 Printed: 11/22/2017 10:01:20 AM
The test results contained within this report meet the requirements of NELAC unless otherwise noted. This report relates only to those items tested. Samples received in good condition unless otherwise noted. Quality Control Data associated with this sample set is within acceptable limits, unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit.
Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ NELAP Certifications: NJ 03036, NY 10872, PA 68-00367
Initial report from 11/22/2017 10:01:20 mailto:cinnaminsonleadlab@emsl.com
OrderID: 201711849
OrderID: 201711849
PCBs in Building Materials
Phillip Worby, Environmental Chemistry Laboratory Director
Approved By:
Fax: (860) 282-1800 Phone: (860) 282-1700
The following analytical report covers the analysis performed on samples submitted to EMSL Analytical, Inc. on 11/13/2017. The results are tabulated on the attached data pages for the following client designated project:
ACELA-001 / Bldg T15
The reference number for these samples is EMSL Order #011709089. Please use this reference when calling about these samples. If you have any questions, please do not hesitate to contact me at (856) 303-2500.
11/27/2017Attn: Ethan Platt Apex Companies, LLC 58H Connecticut Ave.
South Windsor, CT 06074
The test results contained within this report meet the requirements of NELAP and/or the specific certification program that is applicable, unless otherwise noted.
NELAP Certifications: NJ 03036, NY 10872, PA 68-00367, CA ELAP 1877
The samples associated with this report were received in good condition unless otherwise noted. This report relates only to those items tested as received by the laboratory. The QC data associated with the sample results meet the recovery and precision requirements established by the NELAP, unless specifically indicated. All results for soil samples are reported on a dry weight basis, unless otherwise noted. This report may not be reproduced except in full and without written approval by EMSL Analytical, Inc.
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077 Phone: (856) 303-2500 Fax: (856) 858-4571 Email: EnvChemistry2@emsl.com mailto:EnvChemistry2@emsl.com
Phone/Fax: (856) 303-2500 / (856) 858-4571 http://www.EMSL.com EnvChemistry2@emsl.com
011709089 CustomerID: APEX30 CustomerPO:
ProjectID:
EMSL Order:
Analytical Results
Attn: Ethan Platt Apex Companies, LLC 58H Connecticut Ave.
South Windsor, CT 06074
Received: 11/13/17 9:00 AM
ACELA-001 / Bldg T15
Fax: (860) 282-1800 Phone: (860) 282-1700
Project:
Client Sample Description Lab ID:PCB-B-T15-01 011709089-0001 Metal Siding Paint
Collected: 11/7/2017
Method Parameter Result Units Analysis Date AnalystRL
Prep Date Analyst
3540C/8082A Aroclor-1016 EHND mg/Kg 11/27/20170.96 11/24/2017 AB
3540C/8082A Aroclor-1221 EHND mg/Kg 11/27/20170.96 11/24/2017 AB
3540C/8082A Aroclor-1232 EHND mg/Kg 11/27/20170.96 11/24/2017 AB
3540C/8082A Aroclor-1242 EHND mg/Kg 11/27/20170.96 11/24/2017 AB
3540C/8082A Aroclor-1248 EHND mg/Kg 11/27/20170.96 11/24/2017 AB
3540C/8082A Aroclor-1254 EHND mg/Kg 11/27/20170.96 11/24/2017 AB
3540C/8082A Aroclor-1260 EHND mg/Kg 11/27/20170.96 11/24/2017 AB
3540C/8082A Aroclor-1262 EHND mg/Kg 11/27/20170.96 11/24/2017 AB
3540C/8082A Aroclor-1268 EHND mg/Kg 11/27/20170.96 11/24/2017 AB
Client Sample Description Lab ID:PCB-B-T15-02 011709089-0002 Window Glazing
Collected: 11/7/2017
Method Parameter Result Units Analysis Date AnalystRL
Prep Date Analyst
3540C/8082A Aroclor-1016 EHND mg/Kg 11/27/20170.96 11/24/2017 AB
3540C/8082A Aroclor-1221 EHND mg/Kg 11/27/20170.96 11/24/2017 AB
3540C/8082A Aroclor-1232 EHND mg/Kg 11/27/20170.96 11/24/2017 AB
3540C/8082A Aroclor-1242 EHND mg/Kg 11/27/20170.96 11/24/2017 AB
3540C/8082A Aroclor-1248 EHND mg/Kg 11/27/20170.96 11/24/2017 AB
3540C/8082A Aroclor-1254 EHND mg/Kg 11/27/20170.96 11/24/2017 AB
3540C/8082A Aroclor-1260 EHND mg/Kg 11/27/20170.96 11/24/2017 AB
3540C/8082A Aroclor-1262 EHND mg/Kg 11/27/20170.96 11/24/2017 AB
3540C/8082A Aroclor-1268 EHND mg/Kg 11/27/20170.96 11/24/2017 AB
Client Sample Description Lab ID:PCB-B-T15-03 011709089-0003 Wood Siding Paint
Collected: 11/7/2017
Method Parameter Result Units Analysis Date AnalystRL
Prep Date Analyst
3540C/8082A Aroclor-1016 EHND mg/Kg 11/27/20170.98 11/24/2017 AB
3540C/8082A Aroclor-1221 EHND mg/Kg 11/27/20170.98 11/24/2017 AB
3540C/8082A Aroclor-1232 EHND mg/Kg 11/27/20170.98 11/24/2017 AB
3540C/8082A Aroclor-1242 EHND mg/Kg 11/27/20170.98 11/24/2017 AB
3540C/8082A Aroclor-1248 EHND mg/Kg 11/27/20170.98 11/24/2017 AB
3540C/8082A Aroclor-1254 EHND mg/Kg 11/27/20170.98 11/24/2017 AB
3540C/8082A Aroclor-1260 EHND mg/Kg 11/27/20170.98 11/24/2017 AB
3540C/8082A Aroclor-1262 EHND mg/Kg 11/27/20170.98 11/24/2017 AB
3540C/8082A Aroclor-1268 EHND mg/Kg 11/27/20170.98 11/24/2017 AB
Page 2 of 3ChemSmplw/RDL/NELAC-7.44.3 Printed: 11/27/2017 5:30:28 PM
Phone/Fax: (856) 303-2500 / (856) 858-4571 http://www.EMSL.com EnvChemistry2@emsl.com
011709089 CustomerID: APEX30 CustomerPO:
ProjectID:
EMSL Order:
Analytical Results
Attn: Ethan Platt Apex Companies, LLC 58H Connecticut Ave.
South Windsor, CT 06074
Received: 11/13/17 9:00 AM
ACELA-001 / Bldg T15
Fax: (860) 282-1800 Phone: (860) 282-1700
Project:
Client Sample Description Lab ID:PCB-B-T15-04 011709089-0004 Metal to wood Siding Sealer
Collected: 11/7/2017
Method Parameter Result Units Analysis Date AnalystRL
Prep Date Analyst
3540C/8082A Aroclor-1016 EHND mg/Kg 11/27/20170.95 11/24/2017 AB
3540C/8082A Aroclor-1221 EHND mg/Kg 11/27/20170.95 11/24/2017 AB
3540C/8082A Aroclor-1232 EHND mg/Kg 11/27/20170.95 11/24/2017 AB
3540C/8082A Aroclor-1242 EHND mg/Kg 11/27/20170.95 11/24/2017 AB
3540C/8082A Aroclor-1248 EHND mg/Kg 11/27/20170.95 11/24/2017 AB
3540C/8082A Aroclor-1254 EHND mg/Kg 11/27/20170.95 11/24/2017 AB
3540C/8082A Aroclor-1260 EHND mg/Kg 11/27/20170.95 11/24/2017 AB
3540C/8082A Aroclor-1262 EHND mg/Kg 11/27/20170.95 11/24/2017 AB
3540C/8082A Aroclor-1268 EHND mg/Kg 11/27/20170.95 11/24/2017 AB
ND - indicates that the analyte was not detected at the reporting limit RL - Reporting Limit (Analytical)
Definitions:
Page 3 of 3ChemSmplw/RDL/NELAC-7.44.3 Printed: 11/27/2017 5:30:28 PM
OrderID: 011709089
PCBs in Soil
Phillip Worby, Environmental Chemistry Laboratory Director
Approved By:
Fax: (860) 282-1800 Phone: (860) 282-1700
The following analytical report covers the analysis performed on samples submitted to EMSL Analytical, Inc. on 11/13/2017. The results are tabulated on the attached data pages for the following client designated project:
ACELA-001
The reference number for these samples is EMSL Order #011709078. Please use this reference when calling about these samples. If you have any questions, please do not hesitate to contact me at (856) 303-2500.
11/27/2017Attn: Ethan Platt Apex Companies, LLC 58H Connecticut Ave.
South Windsor, CT 06074
The test results contained within this report meet the requirements of NELAP and/or the specific certification program that is applicable, unless otherwise noted.
NELAP Certifications: NJ 03036, NY 10872, PA 68-00367, CA ELAP 1877
The samples associated with this report were received in good condition unless otherwise noted. This report relates only to those items tested as received by the laboratory. The QC data associated with the sample results meet the recovery and precision requirements established by the NELAP, unless specifically indicated. All results for soil samples are reported on a dry weight basis, unless otherwise noted. This report may not be reproduced except in full and without written approval by EMSL Analytical, Inc.
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077 Phone: (856) 303-2500 Fax: (856) 858-4571 Email: EnvChemistry2@emsl.com
Phone/Fax: (856) 303-2500 / (856) 858-4571 http://www.EMSL.com EnvChemistry2@emsl.com
011709078 CustomerID: APEX30 CustomerPO:
ProjectID:
EMSL Order:
Analytical Results
Attn: Ethan Platt Apex Companies, LLC 58H Connecticut Ave.
South Windsor, CT 06074
Received: 11/13/17 9:00 AM
ACELA-001
Fax: (860) 282-1800 Phone: (860) 282-1700
Project:
Client Sample Description Lab ID:PCB-715-9 011709078-0001 West Site
Collected: 11/7/2017
Method Parameter Result Units Analysis Date AnalystRL
Prep Date Analyst
SM 2540G Total Solids MM89 % 11/14/20170.0 11/14/2017 MM
3550C/8082A Aroclor-1016 EHND µg/Kg 11/14/201719 11/14/2017 SD
3550C/8082A Aroclor-1221 EHND µg/Kg 11/14/201719 11/14/2017 SD
3550C/8082A Aroclor-1232 EHND µg/Kg 11/14/201719 11/14/2017 SD
3550C/8082A Aroclor-1242 EHND µg/Kg 11/14/201719 11/14/2017 SD
3550C/8082A Aroclor-1248 EHND µg/Kg 11/14/201719 11/14/2017 SD
3550C/8082A…