20260427 Cobb_Douglas Public Health Drawings.pdf
PDF 6 MB Posted
- Attached to
- Public Health Building Renovation
- Solicitation number
- PE-64800-NONST-2026-000000083
- Issued by
- Douglas County, Georgia
About this file
This architectural drawing package supports Douglas County's Request for Proposal for the design, permitting, site preparation, expansion, and remodel of the Douglas County Public Health Center located at 6770 Selman Drive, Douglasville, Georgia 30134. The drawings dated April 27, 2026, depict a comprehensive renovation project that includes a proposed new building footprint with approximately 4,992 square feet of new site work to earth. The floor plan illustrates a single-level facility organized into multiple functional areas, including clinical spaces with eight examination rooms, a laboratory, nurses' station, blood draw area, and hearing/vision screening rooms, alongside administrative offices, staff facilities, and patient amenities such as waiting areas, break rooms, and storage areas. The design incorporates specialized spaces for nutrition services, WIC programs, EHDI screening, car seat installation, and pediatric care, along with required support functions including mechanical systems, electrical rooms, and janitorial storage. Site plans show the removal of existing ramped drive infrastructure and infill of existing asphalt surfaces with pedestal paver systems. Building elevations depict a modern healthcare facility constructed with CMU, lighter and darker brick, metal panels, and solar shade elements, with building height reaching approximately 15 feet 8 inches to the existing parapet.
The project will be funded through a combination of Cobb & Douglas Public Health reserve funds and appropriations from the Douglas County Board of Commissioners General Fund. The Design-Builder shall be responsible for obtaining and maintaining all permits, approvals, and licenses necessary for design and construction, with all work required to comply with applicable Douglas County requirements and standards of all authorities having jurisdiction. The scope encompasses all services in accordance with applicable federal, state, and local laws, statutes, regulations, ordinances, codes, and permitting requirements.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SE
LM
AN
D
R
PROPOSED NEW BUILDING FOOT PRINT
REMOVE EXISTING RAMPED DRIVE
SITE SET BACKS
SE
LM
AN
D
R
EXISTING
ASPHALT
INFILL
EXISTING
ASPHALT INFILL
ESTIMATED NEW SITE
WORK TO EARTH
4,992 SF
1" = 50'-0"01
1 EXISTING SITE PLAN
1" = 50'-0"01
2 PROPOSED SITE PLAN
SITE PLANS
04/27/2026
6770 SELMAN DR, DOUGLASVILLE, GA 30134
N
03SE
03 NW1
SW
C A R
S E
AT
IN
S
TA
LL
AT
IO
N
116 SF
NUTRITION
107 SF
NUTRITION
106 SF
NUTRITION
38 SF
STAFF RR
61 SF
STAFF ADA
106 SF
NUTRITION
54 SF
ELECTRICAL
38 SF
PATIENT RR
45 SF
PATIENT RR
472 SF
MULTIPURPOSE ROOM
134 SF
MEN'S RR
128 SF
ADMIN FLEX OFFICE SPACE
116 SF
COMPUTER ROOM
117 SF
ADMIN FLEX OFFICE SPACE
69 SF
STAFF RR
67 SF
STAFF RR
138 SF
MECHANICAL
44 SF
JAN
134 SF
WOMEN'S RR
1191 SF
CIRCULATION
189 SF
CIRCULATION
216 SF
CHILDREN 1ST OFFICES
103 SF
CLERK SUPV
116 SF
FLEX/EHDI SCREEN
129 SF
EHDI STAFF
129 SF
HEARING FLEX SPACE
131 SF
PCM FLEX SPACE
93 SF
PCM STAFF
113 SF
PCM STAFF
106 SF
WIC STORAGE
104 SF
AHYD + CDP OFFICE
112 SF
FLEX OFFICE SPACE
173 SF
GENERAL STORAGE
106 SF
FLEX OFFICE SPACE
41 SF
JAN
115 SF
ADMIN FLEX OFFICE SPACE
203 SF
FACILITIES/STOR
74 SF
PARENTING
375 SF
LARGE BREAK ROOM
163 SF
CAR SEAT WAITING AREA
141 SF
SAFE KIDS OFFICE
53 SF
STORAGE
22 SF
UTILITY
108 SF
FLEX OFFICE SPACE
118 SF
FLEX OFFICE SPACE
118 SF
PEER COUNSELOR
111 SF
WIC MGR
477 SF
WIC WORK AREA
107 SF
FLEX OFFICE SPACE
140 SF
STORAGE
110 SF
NUTRITION
120 SF
PEER COUNSELOR
116 SF
TELECOM
70 SF
QUIET SPACE
416 SF
CIRCULATION
126 SF
MECHANICAL
77 SF
VITALS
67 SF
ANTEROOM
75 SF
NEG PRESSURE ISOLATION
112 SF
CLIENT MEETING ROOM (STI)
80 SF
MANAGER
462 SF
NURSES' STATION
87 SF
EXAM
88 SF
EXAM88 SF
EXAM
88 SF
EXAM
88 SF
EXAM
88 SF
EXAM
88 SF
EXAM
88 SF
EXAM
357 SF
LAB
777 SF
LOBBY/WAITING
54 SF
PATIENT RR
59 SF
PATIENT RR
59 SF
BLOOD DRAW
106 SF
CLERK SUPV
195 SF
CLINIC WORK RM
149 SF
BREAK
346 SF
CLINIC CHECK IN
87 SF
HEAR/VIS SCREEN
119 SF
STAFF RR
66 SF
VISION NOOK
RECEPTION
124 SF
STAFF RR
49 SF
STOR
CRASH
CART
NE
41 SF
SPRINKLER
21 SF
STOR
87 SF
HEAR/VIS SCREEN
56 SF
STOR
41 SF
ELEC
95 SF
FLEX
96 SF
FLEX
88 SF
EXAM
PEDESTAL PAVER
INFILL OVER EXISTING
ASPHALT
INFILL OVER EXISTING
ASPHALT
1" = 20'-0"02
1 OVERALL FLOOR PLAN
FLOOR PLAN
04/27/2026
N
LEVEL 01
0' - 0"
T.O. EX PARAPET
15' - 8"
LIGHTER BRICK CMU
LEVEL 01
0' - 0"
T.O. EX PARAPET
15' - 8"
METAL PANEL
DARK BRICKLIGHTER BRICKSOLAR SHADE SOLAR SHADE LIGHTER BRICK CMU
LEVEL 01
0' - 0"
T.O. EX PARAPET
15' - 8"
DARK BRICK CMU EX STORAGE BLDG TO REMAIN CANOPY STRUCTURE
LEVEL 01
0' - 0"
T.O. EX PARAPET
15' - 8"
DARK BRICKLIGHTER BRICKCMU
LEVEL 01
0' - 0"
T.O. EX PARAPET
15' - 8"
METAL PANEL DARK BRICK LIGHTER BRICK CMU
1/16" = 1'-0"03
SW ENTRY ELEVATION - SOUTHWEST
1/16" = 1'-0"03
SE STREET ELEVATION - SOUTHEAST
1/16" = 1'-0"03
NW1 PARKING LOT ELEVATION - NORTHWEST
1/16" = 1'-0"03
NE REAR ELEVATION - NORTHEAST
1/16" = 1'-0"03
NW2 MECH COURTYARD ELEVATION - NORTHWEST
ELEVATIONS
04/27/2026
04/27/2026
| Sheets |
| 01 - SITE PLANS |
| 02 - FLOOR PLAN |
| 03 - ELEVATIONS |