Vibration_Chamber_Air_Ducting_Verification.docx
DOCX document 12 KB Posted
- Attached to
- Reconfiguration of the Vibration Environmental Chamber Box, Duct Work, and Support Structure
- Solicitation number
- 18-233-SOL-00167
About this file
Vibration Chamber Air Ducting
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Q&A.docx | DOCX document | |
| Technical_Requirement_DRD_2637.docx | DOCX document | |
| Answers.pdf | ||
| InitialQuestions.pdf | ||
| UCF_-_Vibration_Chambers_(updated).pdf | ||
| Vibration_Environmental_Box.docx | DOCX document | |
| Vibration_Chamber_Air_Ducting_Verification.docx | DOCX document | |
| Answers.pdf | ||
| Return_Air-Vibration_Chamber.docx | DOCX document | |
| Vibration_Environmental_Box.docx | DOCX document | |
| Return_Air-Vibration_Chamber.docx | DOCX document | |
| Appendix_A-Doc1(Head_Expander).pdf | ||
| UCF_-_Vibration_Chambers_(Updated03-01-2018).pdf | ||
| Appendix_C-Doc2_(Over_View).pdf | ||
| Appendix_B-Doc1_(Layout_Horizontal).pdf | ||
| Appendix_B-Doc2_(Layout_Vertical).pdf | ||
| 18-233-SOL-00167_SF1449.pdf | ||
| UCF_-_Vibration_Chambers.pdf | ||
| Attachment_B_-_Picture.docx | DOCX document | |
| Attachment_A_-_Picture.docx | DOCX document |
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Vibration Chamber Air Ducting Verification
| Supply Air from Equipment Skid: | With no Ducting on 18” Supply Air | ||
| Readings: | 1.86 -1.87 m³/s Flow | ||
| 11.43 – 11.5 m/s | |||
| Return Air to Equipment Skid: | With no Ducting on 18” Return Air | ||
| Readings: | 3.07 m³/s Flow | ||
| 19.53 – 19.66 m/s | |||
| Instrument used to Measure Flow: | ALNOR RVA501 | Anemometer | |
| Calibration ID on Instrument: | RVA501607004 | ||
| Calibration Due Date: | 07 Jan 2019 |
*Measurements taken on 27 February 2018
Vibration Chamber Air Checks inside Chamber W/Doors Closed
Supply Air inside Chamber: See Page 2 for Readings
Return Air inside Chamber: See Page 3 for Reading
| Instrument used to Measure Flow: | ALNOR RVA501 | Anemometer |
| Calibration ID on Instrument: | RVA501607004 | |
| Calibration Due Date: | 07 Jan 2019 |
*Measurements taken on 1 March 2018