Z1DA--528A6-20-609 boiler plant upgrades |

Closed Solicitation Posted

Solicitation number
36C24221B0071
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs is soliciting proposals to provide boiler plant upgrades at the Bath VA Medical Center in Bath, New York. The project consists of two tasks - replacing the water filtration tank and associated equipment, and removing and replacing four digital loop controllers. Contractors must provide lump sum bids for each task, with award going to the lowest total bid. Proposals are due by November 10, 2021.

This project is set aside 100% for Service-Disabled Veteran-Owned Small Businesses. The NAICS code is 238220 for specialty trade contractors, with a small business size standard of $16.5 million. The place of performance is the Bath VA Medical Center. The estimated value is between $100,000 to $250,000, and a 20% bid bond must be submitted with proposals. All work must be completed within 120 days of award.

Notice text

THIS IS A PRE-SOLICITATION NOTICE SYNOPSIZING AN UPCOMING COMPETITIVE SOLICITATION SATISFYING THE REQUIREMENTS OF FAR 5.201 AND 5.203 AN INVITATION FOR BIDS WILL BE POSTED ON OR ABOUT OCTOBER 4, 2021

Boiler Plant Upgrades, Bath VA Medical Center Procurement Number: 36C24221B0071 Project Number: 528A6-20-609

The Bath VA Medical Center (VAMC) will be posting a solicitation to provide all labor, materials, tools, equipment, and supervision necessary to perform work under project number 528A6-20-609 titled Boiler Plant Upgrades. The project will consist of two (2) separate tasks. Contractor is to provide a lump sum bid for each task. Contract will be awarded to the contractor whose sum of both tasks is the lowest. Upon award of contract, Contractor is to issue a submittal for each of the components in the assigned tasks. All work to be completed within 120 days of contract award.

TASK 1 Replace Water Filtration tank and Appurtenances

Basis for design for the water filtration tanks are Yardney Multi-Media Filter System, Model #MM5460- 3A, serial #39516 or approved equal. Perform the following tasks:

Disconnect all piping suppling filtration tanks

Remove insulation

Remove filter media

Dispose of filter media

Re-bed the tank in the following manner:

Install new filter media in each media tank with the following media and quantities:

Bottom layer - 5/8 x 3/8 gravel underbedding 38, 80# bags

Next layer 1.45 mm garnet 70, 50# bags

Next layer - .035 mm Garnet 180, 50# bags

Top layer 0.8-0.9 mm anthracite 72, 50# bag

Note: SDS sheets and documentation stating that filter media meets AWWA and NSF potable water standards must be provided to Water Plant Supervisor for NYSDOH review and approval. No work can be done until approval by NYSDOH is given.

Re-insulate tank

Back flush system

Start up and ensure proper operation of system

TASK 2 - Replacing the Existing Digital Loop Controllers

Remove four (4) of the existing digital loop controllers and replace in kind with new, state of the art digital controllers which shall include testing and calibration. Re-wire as necessary. Basis of design is the PCC IV manufactured by Preferred Utilities Manufacturing Corporation.

**Additional information will be provided in the Statement of Work which will be posted with the solicitation.

The NAICS code for this procurement is 238220 with a small business size standard of $16.5 million. The magnitude of this project is between $100,000 and $250,000. A 20% bid bond will be required and must be submitted with the bid. This project is 100% set-aside for Service-Disabled Veteran-Owned Small Businesses.

Files

File Type Posted
S06 Yardney Filter DAta Sheet.pdf PDF
S06 Yardney Filter Tanks.jpg JPG image
36C24221B0071 0004.docx DOCX document
36C24221B0071 0003.docx DOCX document
36C24221B0071 0002.docx DOCX document
P07 Wage Determination.docx DOCX document
S06 Certification of Vaccination.pdf PDF
S06 05779335 082621 003 CAO Memorandum - Attestation Guidance for Health and Safety Precautions for COVID-19 - Aug 25 2021 (1).pdf PDF
2021 Boiler Plant Upgrades SOW-r1.docx DOCX document
36C24221B0071 0001.docx DOCX document
36C24221B0071_1.docx DOCX document
Show all 11

Notice history

Notice Type Posted
This notice Latest solicitation Solicitation
Z1DA--528A6-20-609 boiler plant upgrades | Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Z1DA--Project 695-24-107 Replace Boilers 4 and 5 Clement J. Zablocki, VA Medical Center 5000 West National Avenue Milwaukee, WI 53295 United States · NAICS 238220 Veterans Integrated Service Network 12 Service-Disabled Veteran-Owned Small Business
Z1DA--FY27 NRM - Replace B98 and B88 Boiler and Sump Pumps Department of Veterans Affairs Va Northern California Health Care System McClellan Park CA 95652, United States · NAICS 236220 Veterans Integrated Service Network 21 No set-aside
Z1DA--550-20-121 Demo Old Boiler Plant B100 (CON) Veterans Affairs Illiana Healthcare System -Vaihcs Danville, Illinois 61832, United States · NAICS 236220 Veterans Integrated Service Network 12 Service-Disabled Veteran-Owned Small Business
Z2DA--FY27 NRM | 557-23-104 | Replace Boiler Plant Steam Boilers | Construction (VA-27-00003633) Carl Vinson VA Medical Center Dublin GA 31021 · NAICS 236220 Veterans Integrated Service Network 7 Service-Disabled Veteran-Owned Small Business
Z2DA--FY27 NRM 558-24-160, Domestic Water, Chilled Water and Steam Piping (VA-26-00066009) Durham, North Carolina 27705, United States · NAICS 236220 Veterans Integrated Service Network 6 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity