J065--Parrott: Reviewed and ready- JB 5 and 3-year Standpipe Testing Johnson Controls Inc
Closed Pre-Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 36C25224Q0087
- Agency
-
Veterans Integrated Service Network 12
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Place of performance
- Jesse Brown Vamc Chicago, Illinois 60612, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Great Lakes Acquisition Center seeks to procure standpipe testing services at the Jesse Brown VA Medical Center in Chicago, Illinois. Interested vendors must be capable of performing five-year standpipe hydrostatic flow tests and three-year leakage tests for wet and dry fire suppression systems as required by NFPA Code 25 and The Joint Commission. Capability statements are due by November 9, 2023 at 5:00 PM Central time and must demonstrate company experience, customer references, authorization and training to service equipment, and number of qualified maintenance personnel. This notice is issued for market research purposes only and does not constitute a solicitation.
There is no set-aside designation. The NAICS code is 238210 for plumbing, heating, and air-conditioning contractors. The contractor shall provide testing for 17 standpipes and all necessary labor, materials, tools, transportation, management, and equipment to conduct five-year testing of wet systems and three-year leakage testing of dry systems as required by applicable codes and regulations.
Notice text
Page 2 of 2
The Department of Veterans Affairs, Great Lakes Acquisition Center (GLAC) is searching for vendors with the capabilities to provide Standpipe testing. This service is needed for is the Jesse Brown VAMC in Chicago IL.
The contractor shall furnish all labor, transportation, parts, test equipment, tools, and expertise necessary to perform Standpipe Testing. The contractor shall provide the following coverage: complete parts and labor, maintenance and service, to include all components for the standpipe testing. Contractor to perform 5-year standpipe hydrostatic flow test as required per Joint Commission and NFPA Code 25 for 17 standpipes:
The Contractor shall be able to provide all labor, materials, tools, travel, management, and equipment necessary to provide 5-year standpipe testing for the wet fire suppression system as well as 3-year leakage test for dry system as required per NFPA code 25 and Joint Commission EC.02.03.05 EP12.
The North American Industry Classification System (NAICS) code for this procurement is 238210.
All interested, responsible sources must submit a capability statement by Thursday, November 09, 2023, by 5PM Central time, to Romell.Parrott@va.gov to include the following:
The Contractor shall be able to provide all labor, materials, tools, travel, management, and equipment necessary to provide 5-year standpipe testing for the wet fire suppression system as well as 3-year leakage test for dry system as required per NFPA code 25 and Joint Commission EC.02.03.05 EP12.
Company Experience in providing maintenance testing and repair services to referenced stand pipe testing, to include number of years and any examples of current contracts in place with government or commercial entities;
Customer point of contact information for contracts listed in company experience along with a description of equipment serviced under the contract.
Verification of authorization and training related to servicing referenced equipment;
Number of qualified maintenance personnel employed.
DUNS number, organization name, organization address, point of contact, business size under NAICS 238210, and socioeconomic status.
This Sources Sought is issued solely for information and planning purposes to determine availability of qualified vendors and does not constitute a solicitation. All information received in response to this Sources Sought that is marked as proprietary will be handled accordingly. Please note that this is not a request for proposal and the Government is seeking information for market research purposes only. The Government may or may not issue solicitation documents. Look for any further information in Contract Opportunities. Telephone inquiries will not be returned.
Files
| File | Type | Posted |
|---|---|---|
| 36C25224Q0087.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| J065--Parrott *Special* Standpipe Testing 5 yr wet/3 yr dry | Award Notice | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| J012--Fire Suppression Testing | Veterans Integrated Service Network 8 | Service-Disabled Veteran-Owned Small Business | |
| J043--Damen Sump Pump Control System Repair | Veterans Integrated Service Network 12 | No set-aside | |
| H212-- Fire Pump Test and Alarm support | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| J042--Fire Alarm System Monitoring and Programming INTENT TO SOLE SOURCE | Veterans Integrated Service Network 12 | No set-aside | |
| B533--VANIHCS SPS Water Testing (VA-27-00000760) | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity